{"files":[{"bytes":18368,"name":"index.html","sha256":"2bc5f89c29da20d4fba031d5d6327dc32ae7ffec4dc4120c5a95010aa2ea5f00"},{"bytes":7957,"name":"publication.md","sha256":"af20055bea62350abf208094a98dad1617b421bc0313d8edee722fe4173835f8"},{"bytes":7627,"name":"publication.txt","sha256":"35f53426f9b8250c86e20644e7db705948d24ea19069317aa7962352367fef9f"},{"bytes":2847,"name":"manifest.json","sha256":"a8352f8b804555d3daed45e34f28f9f6ffd98922009e6578c255201022d02069"},{"bytes":89,"name":"manifest.sig","sha256":"00aa68529d1f64b8239b2b13fcddcb462d5f80cd465effe53093d461983fd8fd"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4d94f91795e2d05c86843fcc2738072d52d3b998229743869c53111cfad37e70"}],"publication_id":"OT-2026-000089033"} Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089033
OpenTechnical

OT-2026-000089033

Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
35f53426f9b8250c86e20644e7db705948d24ea19069317aa7962352367fef9f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089033, “Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089033.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089033" title: "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089033" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089033 Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089033 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089033 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089033 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089033", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18368, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2bc5f89c29da20d4fba031d5d6327dc32ae7ffec4dc4120c5a95010aa2ea5f00" }, { "bytes": 7957, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "af20055bea62350abf208094a98dad1617b421bc0313d8edee722fe4173835f8" }, { "bytes": 7627, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "35f53426f9b8250c86e20644e7db705948d24ea19069317aa7962352367fef9f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089033/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089033", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7509-af27-259c1c00beeb" } Pj4kKV1T+wPYZUbDOSkLYxDIJrilk0pUl5pm62HiKz7cSsGPPjktLG2rCK3SMy1+TQbZRJo1baX1tOVGvSkqCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Pj4kKV1T+wPYZUbDOSkLYxDIJrilk0pUl5pm62HiKz7cSsGPPjktLG2rCK3SMy1+TQbZRJo1baX1tOVGvSkqCQ== {"files":[{"bytes":19183,"name":"index.html","sha256":"e94bf42d212ea1cf702b36d84453b9b2353f28de3bac50c763720fbe5d2cd2b1"},{"bytes":8658,"name":"publication.md","sha256":"9a60b51d8f5cc7c480152494c4b9792cd6e5c70696d7938089f9401df0001062"},{"bytes":8322,"name":"publication.txt","sha256":"c98e83fb8af126ad203ad7abd4bf9d0eac10d8c58cee8849b85112d68050472f"},{"bytes":2859,"name":"manifest.json","sha256":"a89693405b5d590499c07fbceeb49dd9eb69d675af0cea7bdcb9d06a62aae5b3"},{"bytes":89,"name":"manifest.sig","sha256":"67476d0684a829a81f1bf89aadf4c17342e0675e4992f043d5e308d108d146b6"},{"bytes":227,"name":"manifest.sig.txt","sha256":"42a397feb8f7a0ab57a8716f7742628c6a44577d43133ffa022f9406e3a99db3"}],"publication_id":"OT-2026-000089034"} Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089034
OpenTechnical

OT-2026-000089034

Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c98e83fb8af126ad203ad7abd4bf9d0eac10d8c58cee8849b85112d68050472f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089034, “Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089034.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089034" title: "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089034" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089034 Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089034 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089034 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089034 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089034", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19183, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "e94bf42d212ea1cf702b36d84453b9b2353f28de3bac50c763720fbe5d2cd2b1" }, { "bytes": 8658, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9a60b51d8f5cc7c480152494c4b9792cd6e5c70696d7938089f9401df0001062" }, { "bytes": 8322, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c98e83fb8af126ad203ad7abd4bf9d0eac10d8c58cee8849b85112d68050472f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089034/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089034", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7b8f-943e-c31ae3baf46e" } iftHcD7QuCRs+nbcKo55d6I+n01TG/mDsXZjnD71GXj8LlmQKyI5yOTo46I2+YHk1mIlsJq3EPFlyxtW8MtMBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: iftHcD7QuCRs+nbcKo55d6I+n01TG/mDsXZjnD71GXj8LlmQKyI5yOTo46I2+YHk1mIlsJq3EPFlyxtW8MtMBg== {"files":[{"bytes":18930,"name":"index.html","sha256":"5993d756e9ef0460352f28783a0e8c62dfd7dd84d81551f617d80d8705adcfcd"},{"bytes":8448,"name":"publication.md","sha256":"7c202b8a9f4c8225c6c149a12eecc4d2ca18f269a7d10a7bb6b7fdde1e9e7ce4"},{"bytes":8112,"name":"publication.txt","sha256":"fe39856a9912826043df353e21b1b5560cda14dfbb2d38d35ae4eabaa7b066df"},{"bytes":2859,"name":"manifest.json","sha256":"64fd0a302110909fec773535f84557e07e978f03bbdeb78e1de357c052c74bf2"},{"bytes":89,"name":"manifest.sig","sha256":"a30aa9cd4f13200deaae26cd0153223b8b87f11d044616c93675a51e30914eae"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c6201c4159656e0da2375ab2188de0121108cbc6eb2e67257684256bcbeaab33"}],"publication_id":"OT-2026-000089035"} Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089035
OpenTechnical

OT-2026-000089035

Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
fe39856a9912826043df353e21b1b5560cda14dfbb2d38d35ae4eabaa7b066df

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089035, “Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089035.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089035" title: "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089035" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089035 Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089035 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089035 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089035 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089035", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18930, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5993d756e9ef0460352f28783a0e8c62dfd7dd84d81551f617d80d8705adcfcd" }, { "bytes": 8448, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7c202b8a9f4c8225c6c149a12eecc4d2ca18f269a7d10a7bb6b7fdde1e9e7ce4" }, { "bytes": 8112, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fe39856a9912826043df353e21b1b5560cda14dfbb2d38d35ae4eabaa7b066df" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089035/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089035", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7594-9db8-0c77990424d1" } ZtPq2WqFDA5D3eOrCtU0bh/2QbmPK6MW1CwuMNfpZtzogkEW0OKkwMscoOfjwnJDvCsH8Ju4eETrK7BITy6WBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ZtPq2WqFDA5D3eOrCtU0bh/2QbmPK6MW1CwuMNfpZtzogkEW0OKkwMscoOfjwnJDvCsH8Ju4eETrK7BITy6WBw== {"files":[{"bytes":18368,"name":"index.html","sha256":"823886ea469b3270495ef126b4e0123a141a2314966a5bf6b9ce58a9a0c7e872"},{"bytes":7957,"name":"publication.md","sha256":"b7b5ef61c665ffc87d4afdd653ec39fe7780d45ccd18999d2c03b22f7f1569e3"},{"bytes":7627,"name":"publication.txt","sha256":"e2fa4346f530ed570f516998cf513c43a71ffdccd81e938ad16e029a1c75e558"},{"bytes":2847,"name":"manifest.json","sha256":"1f954f425908a401408b01ee99b42d01404db36977e1f789be79f4e69817691b"},{"bytes":89,"name":"manifest.sig","sha256":"192beb7fd0368316a111e9bf107ec7ae0f24deb6ee7fa5d6b74b9476ab761e74"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0d97f12a239cfca8a84bb7d63d9f1633ffe44278d0f243bb2ba5ade490d10132"}],"publication_id":"OT-2026-000089036"} Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089036
OpenTechnical

OT-2026-000089036

Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
e2fa4346f530ed570f516998cf513c43a71ffdccd81e938ad16e029a1c75e558

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089036, “Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089036.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089036" title: "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089036" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089036 Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089036 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089036 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089036 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089036", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18368, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "823886ea469b3270495ef126b4e0123a141a2314966a5bf6b9ce58a9a0c7e872" }, { "bytes": 7957, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b7b5ef61c665ffc87d4afdd653ec39fe7780d45ccd18999d2c03b22f7f1569e3" }, { "bytes": 7627, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e2fa4346f530ed570f516998cf513c43a71ffdccd81e938ad16e029a1c75e558" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089036/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089036", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7304-9043-9894030fba36" } JCD9bNzJrRd1tUE+OZgEiWJNGokl2aoIY5WGDUorsXIrQQHEZNpVbbxDfd/HFkiQxSIUFkHYdaKI9h/Y798KAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: JCD9bNzJrRd1tUE+OZgEiWJNGokl2aoIY5WGDUorsXIrQQHEZNpVbbxDfd/HFkiQxSIUFkHYdaKI9h/Y798KAg== {"files":[{"bytes":19183,"name":"index.html","sha256":"a7999c763709ec56ebfb80ee91bb283e2f77a20fcc229f018bbec81c215bdc43"},{"bytes":8658,"name":"publication.md","sha256":"244eb5344c402bae101f8cf19de5a5fc7d6fa67645428dcca955f051dbfee25a"},{"bytes":8322,"name":"publication.txt","sha256":"1471f8fd100fa012fb9d76834510dab4a45ffb11ee9d853b5c09257ea5aeee8a"},{"bytes":2859,"name":"manifest.json","sha256":"5562337e889790cda114ef3388356c47af1f7f59bac851ef8b8cac5e4b6f63f8"},{"bytes":89,"name":"manifest.sig","sha256":"5c1f607e84bb240146b1fa572707365eac77a55c8c3baeb9d43008868758ab08"},{"bytes":227,"name":"manifest.sig.txt","sha256":"6146ed8529a50245bf9945b1957fe76667599da2abca3b8f5fb3b6bfa493a112"}],"publication_id":"OT-2026-000089037"} Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089037
OpenTechnical

OT-2026-000089037

Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
1471f8fd100fa012fb9d76834510dab4a45ffb11ee9d853b5c09257ea5aeee8a

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089037, “Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089037.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089037" title: "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089037" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089037 Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089037 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089037 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089037 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089037", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19183, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a7999c763709ec56ebfb80ee91bb283e2f77a20fcc229f018bbec81c215bdc43" }, { "bytes": 8658, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "244eb5344c402bae101f8cf19de5a5fc7d6fa67645428dcca955f051dbfee25a" }, { "bytes": 8322, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1471f8fd100fa012fb9d76834510dab4a45ffb11ee9d853b5c09257ea5aeee8a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089037/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089037", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-799e-991e-ea39fd24dbf4" } kJjOA54RGKpcuHfA5z9mRiG5JWw67JkaKRfP28PdOFPfU4w4U26D1NjqZ3laf1xc8z6gPcskeTd90Zba5s/hCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: kJjOA54RGKpcuHfA5z9mRiG5JWw67JkaKRfP28PdOFPfU4w4U26D1NjqZ3laf1xc8z6gPcskeTd90Zba5s/hCg== {"files":[{"bytes":18930,"name":"index.html","sha256":"70bb5b26f74d4ddd58c4538dc6df771309460221f1268cb65cc63849afd539a5"},{"bytes":8448,"name":"publication.md","sha256":"b2ca312a7b1716d44af1c99bcf9ea93fe5b7138feb15856059dbaff878bf8f24"},{"bytes":8112,"name":"publication.txt","sha256":"c08a90e5eb338a2c5f43b0a299184614b94943ab843e0dcbbd750ee5f96a37d9"},{"bytes":2859,"name":"manifest.json","sha256":"075c7db313f51c709af3d83922934dc49e700235c3aa8ec59e2924dda6346b2f"},{"bytes":89,"name":"manifest.sig","sha256":"5c4f68e9b9be09995363ccaeea5bd86f91c9f85a977888e7f55941a68466ccb7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d3c2468f32c0de9d1cb0e8704e0bc1a6659d0c9c0a2d233c42c43cf48dfcc2a5"}],"publication_id":"OT-2026-000089038"} Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089038
OpenTechnical

OT-2026-000089038

Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c08a90e5eb338a2c5f43b0a299184614b94943ab843e0dcbbd750ee5f96a37d9

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089038, “Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089038.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089038" title: "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089038" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089038 Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089038 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089038 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089038 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089038", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18930, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "70bb5b26f74d4ddd58c4538dc6df771309460221f1268cb65cc63849afd539a5" }, { "bytes": 8448, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b2ca312a7b1716d44af1c99bcf9ea93fe5b7138feb15856059dbaff878bf8f24" }, { "bytes": 8112, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c08a90e5eb338a2c5f43b0a299184614b94943ab843e0dcbbd750ee5f96a37d9" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089038/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089038", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7bad-8418-90b88cc80a7b" } RFL3z5sZXbVVH+6rbuUSdn4279tETkjpJtzIsfkevLXUKCAaz/1Uk6qoiHTO3W5ohIswZOb4Nfu6fNFi+kcZCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: RFL3z5sZXbVVH+6rbuUSdn4279tETkjpJtzIsfkevLXUKCAaz/1Uk6qoiHTO3W5ohIswZOb4Nfu6fNFi+kcZCw== {"files":[{"bytes":18381,"name":"index.html","sha256":"7144239d98364adc73bc7df640b545698c1340ecc0be30d0411d244fdc131b15"},{"bytes":8023,"name":"publication.md","sha256":"2a4fa64a1c4b513eabb9fa20ca5595edfa7cc1019456b94e562ea5654ec65112"},{"bytes":7665,"name":"publication.txt","sha256":"0e1ed5ff9eff00281e71e714a2c3c300a4298458df37ec0660c878f894620662"},{"bytes":2907,"name":"manifest.json","sha256":"f0c332f9b50295c0e2527eb81a72623c06e3d2ba667b53d8a58368939a0bae98"},{"bytes":89,"name":"manifest.sig","sha256":"006c0bd2939cd861ae025eee9a3568c6e47ec0b5138362b8f1bce9352edbca7c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"93b7ef40e3c2e9956c9c23e2cd03db1cb05e84a84ad8b0cd29036b3e49557c16"}],"publication_id":"OT-2026-000089039"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089039
OpenTechnical

OT-2026-000089039

Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
0e1ed5ff9eff00281e71e714a2c3c300a4298458df37ec0660c878f894620662

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089039, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089039.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089039" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089039" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089039 Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089039 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089039 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089039 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089039", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1096 }, "figures": [], "files": [ { "bytes": 18381, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7144239d98364adc73bc7df640b545698c1340ecc0be30d0411d244fdc131b15" }, { "bytes": 8023, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "2a4fa64a1c4b513eabb9fa20ca5595edfa7cc1019456b94e562ea5654ec65112" }, { "bytes": 7665, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0e1ed5ff9eff00281e71e714a2c3c300a4298458df37ec0660c878f894620662" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089039/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089039", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7feb-ab95-fb908867c2a8" } /ayj7chUwVVhQqQICKINlV1DzRh4gcwGWcjdMrg/J12kdDZSt1q18FpgiQqK077BGrbqSpmyCEbiqrNbCOVDDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: /ayj7chUwVVhQqQICKINlV1DzRh4gcwGWcjdMrg/J12kdDZSt1q18FpgiQqK077BGrbqSpmyCEbiqrNbCOVDDA== {"files":[{"bytes":19187,"name":"index.html","sha256":"803a7c9c0da35c4dc2b282029e6a4ffa727eb32f2a25194ba804f48a0fdd3f5e"},{"bytes":8711,"name":"publication.md","sha256":"8cff47ceda9d046c78e5d6f07b15ef8ad0f2817e4b64f4a2d750bc3d5ac5486e"},{"bytes":8354,"name":"publication.txt","sha256":"cebb5ec607537876fdf1039d2b24d1284e8355293cc8498a70bbb35508f6339e"},{"bytes":2912,"name":"manifest.json","sha256":"65255f81fc9cbdb308b43f53f3c534f4295e083ce2005da3957f8d7359f71803"},{"bytes":89,"name":"manifest.sig","sha256":"f81860edc453816c184eef899284db3cf3b0dc78673f94b6cc54f5b896e58d02"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e14e343e32669f197b56ef38db3247ab351edf0b155b8a70e15a85fbe3b57919"}],"publication_id":"OT-2026-000089040"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089040
OpenTechnical

OT-2026-000089040

Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cebb5ec607537876fdf1039d2b24d1284e8355293cc8498a70bbb35508f6339e

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089040, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089040.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089040" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089040" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089040 Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089040 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089040 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089040 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089040", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19187, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "803a7c9c0da35c4dc2b282029e6a4ffa727eb32f2a25194ba804f48a0fdd3f5e" }, { "bytes": 8711, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8cff47ceda9d046c78e5d6f07b15ef8ad0f2817e4b64f4a2d750bc3d5ac5486e" }, { "bytes": 8354, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cebb5ec607537876fdf1039d2b24d1284e8355293cc8498a70bbb35508f6339e" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089040/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089040", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7b64-b490-2b577d365125" } TRxIK6/DIYKmvs/dXer/eL9sSWYw9ptQXcHrtExn6I9t9IIXo4cVDRHogydhPFQhhAXYYBFe4JzBO1aY+3r7Aw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: TRxIK6/DIYKmvs/dXer/eL9sSWYw9ptQXcHrtExn6I9t9IIXo4cVDRHogydhPFQhhAXYYBFe4JzBO1aY+3r7Aw== {"files":[{"bytes":18934,"name":"index.html","sha256":"285773f2602c8910f950ab645ae5429bd10aa87264d5ec57793a28ba498d6eea"},{"bytes":8501,"name":"publication.md","sha256":"314833c7360d07be77f8011089151ac1001c83d331c78543bef04670f2f5724f"},{"bytes":8144,"name":"publication.txt","sha256":"537aabc467b064e571477dcefd68a984461775ddd2e73afe4203b99474c6988a"},{"bytes":2912,"name":"manifest.json","sha256":"1bed098573a5c0a47f7d2a58654db3c3c0dab40ca1a7d3b54db1d3e1e1eb74ab"},{"bytes":89,"name":"manifest.sig","sha256":"5408ac2db2479bc60ee14ad1b3a3793f7cca9ac808399a37c4a03addc7ce3144"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2b1b5fbf1281fd47422c606267eca0c9b7599c2bdb76f8443baf363a60c14f1b"}],"publication_id":"OT-2026-000089041"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089041
OpenTechnical

OT-2026-000089041

Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
537aabc467b064e571477dcefd68a984461775ddd2e73afe4203b99474c6988a

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089041, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089041.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089041" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089041" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089041 Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089041 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089041 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089041 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089041", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1167 }, "figures": [], "files": [ { "bytes": 18934, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "285773f2602c8910f950ab645ae5429bd10aa87264d5ec57793a28ba498d6eea" }, { "bytes": 8501, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "314833c7360d07be77f8011089151ac1001c83d331c78543bef04670f2f5724f" }, { "bytes": 8144, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "537aabc467b064e571477dcefd68a984461775ddd2e73afe4203b99474c6988a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089041/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089041", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7c2b-927e-2dc46e8a2f22" } RlIP5R4jWGLCSn/fw7r9kE1bpWZehrIf5afEsJSZ5yea2ooEc+SAfaRRR1rkxSpFz4YXOvO0ma/pCocKWd4eAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: RlIP5R4jWGLCSn/fw7r9kE1bpWZehrIf5afEsJSZ5yea2ooEc+SAfaRRR1rkxSpFz4YXOvO0ma/pCocKWd4eAg== {"files":[{"bytes":18382,"name":"index.html","sha256":"715267cb2d86791ed0d233cc58ba8c43988b2e311f87f19e0cdd16a22f344450"},{"bytes":8024,"name":"publication.md","sha256":"1a798a5e65bb4feec90b5a328b796c1bbc5665a39d0ec7af80858b65eac56618"},{"bytes":7666,"name":"publication.txt","sha256":"a86640e4188b45236d628170b866e89c6ee87aff0bc1ba1b801f921fc7b91fdf"},{"bytes":2907,"name":"manifest.json","sha256":"96c74e157e367c4b909043ba06e95f23bad1ad520a70c73375252474a622ed69"},{"bytes":89,"name":"manifest.sig","sha256":"e144e8a68ee340e8587c366c404ed48ead469dec4ccba90b32b309398689b9b1"},{"bytes":227,"name":"manifest.sig.txt","sha256":"04fe6588f4f0d615ce5bc2b813995fa1a1b3941b1bf975f3649f68aff89a5e38"}],"publication_id":"OT-2026-000089042"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089042
OpenTechnical

OT-2026-000089042

Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
a86640e4188b45236d628170b866e89c6ee87aff0bc1ba1b801f921fc7b91fdf

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089042, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089042.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089042" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089042" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089042 Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089042 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089042 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089042 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089042", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1096 }, "figures": [], "files": [ { "bytes": 18382, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "715267cb2d86791ed0d233cc58ba8c43988b2e311f87f19e0cdd16a22f344450" }, { "bytes": 8024, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1a798a5e65bb4feec90b5a328b796c1bbc5665a39d0ec7af80858b65eac56618" }, { "bytes": 7666, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a86640e4188b45236d628170b866e89c6ee87aff0bc1ba1b801f921fc7b91fdf" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089042/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089042", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7629-b4ce-2023820193ab" } GQWznep+o0TeHKiJmFJd0PLCtZ05Nn1TBoai5QUoZ2ZXUfn96hkC+Pl4gYYst3t6LFSafqch4EWHHSQHzihdDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: GQWznep+o0TeHKiJmFJd0PLCtZ05Nn1TBoai5QUoZ2ZXUfn96hkC+Pl4gYYst3t6LFSafqch4EWHHSQHzihdDQ== {"files":[{"bytes":19188,"name":"index.html","sha256":"9c48f582defce72985c27ae168a5433431d06afbced90464a780b1479a0b6f02"},{"bytes":8712,"name":"publication.md","sha256":"e52e574801a677101870559ac38c4c7d2418f3a706a54337a9512b593151036f"},{"bytes":8355,"name":"publication.txt","sha256":"aa34c613504fffcd7c058a19dff9b41874ba1aa5aa5aad5f580b6df72d7807c5"},{"bytes":2912,"name":"manifest.json","sha256":"ab52fd15724d769d034f45a3a89b4dec07d5ed548102fd05dcbca7ca13ef2f4e"},{"bytes":89,"name":"manifest.sig","sha256":"3f5780f228563116a6219e54d1070cb8be94e5d91809b0db55a13e47b9fcd1bd"},{"bytes":227,"name":"manifest.sig.txt","sha256":"338531b67c4b3205fd38a87fdd842d6e252b09e542df4a9d9b8444ab936f0802"}],"publication_id":"OT-2026-000089043"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089043
OpenTechnical

OT-2026-000089043

Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
aa34c613504fffcd7c058a19dff9b41874ba1aa5aa5aad5f580b6df72d7807c5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089043, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089043.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089043" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089043" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089043 Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089043 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089043 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089043 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089043", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19188, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9c48f582defce72985c27ae168a5433431d06afbced90464a780b1479a0b6f02" }, { "bytes": 8712, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e52e574801a677101870559ac38c4c7d2418f3a706a54337a9512b593151036f" }, { "bytes": 8355, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "aa34c613504fffcd7c058a19dff9b41874ba1aa5aa5aad5f580b6df72d7807c5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089043/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089043", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7942-bdfa-489ca80b6067" } kGetrpHjDKfIlmZJqz0ewKrvMvDdWAVMO1fEDxXYf4/xqp/DRVjubYTaqNFp+zCbga+awCLPltz4qeGoboePAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: kGetrpHjDKfIlmZJqz0ewKrvMvDdWAVMO1fEDxXYf4/xqp/DRVjubYTaqNFp+zCbga+awCLPltz4qeGoboePAg== {"files":[{"bytes":18935,"name":"index.html","sha256":"2607dfcac3f416c12d7306d1eb3fcd9f419d5f2cf93ae012b593c60612bb2e7f"},{"bytes":8502,"name":"publication.md","sha256":"b169b8fc2087561175a08f94ab232147c1452fb6b9cef637390015768c7fe347"},{"bytes":8145,"name":"publication.txt","sha256":"eadf2a1adfb325c07ccb857d3b8dc8e82a48caccee32eaf887f49b399aa63388"},{"bytes":2912,"name":"manifest.json","sha256":"e176592e03f29904cb8a419f74f078e63f8409f19255884a89e37ae9c7519e6e"},{"bytes":89,"name":"manifest.sig","sha256":"cd99d1e0cf4e942ebdda66cda857362754d25002c4cc123bd9fe2d97a05cfcc3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8a4b1e64e554b0f93d196f3bc14f0d893ec996ec5385b9cde4e2c925c106e500"}],"publication_id":"OT-2026-000089044"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089044
OpenTechnical

OT-2026-000089044

Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
eadf2a1adfb325c07ccb857d3b8dc8e82a48caccee32eaf887f49b399aa63388

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089044, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089044.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089044" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089044" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089044 Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089044 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089044 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089044 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089044", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1167 }, "figures": [], "files": [ { "bytes": 18935, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2607dfcac3f416c12d7306d1eb3fcd9f419d5f2cf93ae012b593c60612bb2e7f" }, { "bytes": 8502, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b169b8fc2087561175a08f94ab232147c1452fb6b9cef637390015768c7fe347" }, { "bytes": 8145, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "eadf2a1adfb325c07ccb857d3b8dc8e82a48caccee32eaf887f49b399aa63388" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089044/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089044", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7e38-a1c2-a5e889754347" } HCShhpcb8OXTkxjpmKUtJslH9vJwwfJxZuld/WGrIbDx6Rq1UttJiInl5UxpfFrT4fD6X1FSCd292oz9p6HuBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: HCShhpcb8OXTkxjpmKUtJslH9vJwwfJxZuld/WGrIbDx6Rq1UttJiInl5UxpfFrT4fD6X1FSCd292oz9p6HuBg== {"files":[{"bytes":18386,"name":"index.html","sha256":"789c02782403d854a7144c38743f13b9528c38cf045a91e6c49d855d2c32f5a3"},{"bytes":8028,"name":"publication.md","sha256":"88ae3134f2fe2fa224a5b5baaa9d780cb6c2d5a9f1afba40e17f876a014ac825"},{"bytes":7670,"name":"publication.txt","sha256":"40169b7ee868fab2616512965016249d64c91368b6e79f161a0426d3061b5ae3"},{"bytes":2907,"name":"manifest.json","sha256":"fbf658e0f6909e68f9f17d64c067750a831526787cc85209652eb76b770952e6"},{"bytes":89,"name":"manifest.sig","sha256":"ac77a9c071fbed590f2180e1edd222648d08d8400be3db7058ec52aed4f20823"},{"bytes":227,"name":"manifest.sig.txt","sha256":"407c836a992947511dab2d4285d616c3c24ac4e60c1736474297ee211ca8f5ca"}],"publication_id":"OT-2026-000089045"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089045
OpenTechnical

OT-2026-000089045

Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
40169b7ee868fab2616512965016249d64c91368b6e79f161a0426d3061b5ae3

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089045, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089045.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089045" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089045" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089045 Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089045 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089045 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089045 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089045", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1096 }, "figures": [], "files": [ { "bytes": 18386, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "789c02782403d854a7144c38743f13b9528c38cf045a91e6c49d855d2c32f5a3" }, { "bytes": 8028, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "88ae3134f2fe2fa224a5b5baaa9d780cb6c2d5a9f1afba40e17f876a014ac825" }, { "bytes": 7670, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "40169b7ee868fab2616512965016249d64c91368b6e79f161a0426d3061b5ae3" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089045/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089045", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7ac8-ba9d-be4fcba144d8" } jWMJvNdq5RXXRdyIiE7Twg3kBtpiNCmgCzYJULyxfyelduJ8Wmvm0pIJ9yzLEt9NlMamBJT6MBYyJALmonj2CQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: jWMJvNdq5RXXRdyIiE7Twg3kBtpiNCmgCzYJULyxfyelduJ8Wmvm0pIJ9yzLEt9NlMamBJT6MBYyJALmonj2CQ== {"files":[{"bytes":19192,"name":"index.html","sha256":"aa0ddbac554ade1cd42bc28b4a9e2e21933cec4e89dc4133935e4464ff7e3bff"},{"bytes":8716,"name":"publication.md","sha256":"cc26ed5c7ee9dfa24670f1ca4a1f48eaed67e632aed39d8a43266923bd86cc7c"},{"bytes":8359,"name":"publication.txt","sha256":"af95186479790249304ed0f84876ce3d127a4f505375043c8cdef0203df34551"},{"bytes":2912,"name":"manifest.json","sha256":"2a2bed81adeae7c9cb56685ef4781d901ba5b56ed4b86cd933cb91780dc03f47"},{"bytes":89,"name":"manifest.sig","sha256":"84c98642a229cb8e2fc8e5866c05d6bf51f4c75691566a2e55fb56ac17f7016b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"eae44743d87c4275b95b88bf3c21b258bfdf5f4c18f840612e8575ec191258a9"}],"publication_id":"OT-2026-000089046"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089046
OpenTechnical

OT-2026-000089046

Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
af95186479790249304ed0f84876ce3d127a4f505375043c8cdef0203df34551

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089046, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089046.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089046" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089046" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089046 Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089046 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089046 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089046 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089046", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19192, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "aa0ddbac554ade1cd42bc28b4a9e2e21933cec4e89dc4133935e4464ff7e3bff" }, { "bytes": 8716, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cc26ed5c7ee9dfa24670f1ca4a1f48eaed67e632aed39d8a43266923bd86cc7c" }, { "bytes": 8359, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "af95186479790249304ed0f84876ce3d127a4f505375043c8cdef0203df34551" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089046/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089046", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-75a2-bd3e-c516fedfb9a6" } 7gZmHYWFc+bYyzL+OajMY2mGQ1G8FJVhq6nvVaHlOCjiQz7J/dBN9wLrGYkUZ7ohMBpBw0CQzqkHc0g5iybyBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 7gZmHYWFc+bYyzL+OajMY2mGQ1G8FJVhq6nvVaHlOCjiQz7J/dBN9wLrGYkUZ7ohMBpBw0CQzqkHc0g5iybyBA== {"files":[{"bytes":18939,"name":"index.html","sha256":"2afe7ebf4be418f461e4ef3b4b39b1728a7d9555eeb8c50cd5244179198d6cff"},{"bytes":8506,"name":"publication.md","sha256":"cf6e3242bc94bc6e6f7eb6c27458e328d2746fdb93e05ba98bfe0f9a691afad5"},{"bytes":8149,"name":"publication.txt","sha256":"824011483e3e7e6becc2e081de1c4e25239e673b8f0b8540f01f9ca6de9811bd"},{"bytes":2912,"name":"manifest.json","sha256":"4de2e3645f002d6b12a789e9c1657a7dc23e159d48dd4c585c81e581c41d579d"},{"bytes":89,"name":"manifest.sig","sha256":"1bd4c83e79cfbc3a7781330f60aaf6346df304cdf312b5977beb686fa4f92045"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f6b4e280ec9df411734c87032b719a4bca9e2181a4de48701da7d592d35ac0a3"}],"publication_id":"OT-2026-000089047"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089047
OpenTechnical

OT-2026-000089047

Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
824011483e3e7e6becc2e081de1c4e25239e673b8f0b8540f01f9ca6de9811bd

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089047, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089047.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089047" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089047" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089047 Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089047 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089047 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089047 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089047", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1167 }, "figures": [], "files": [ { "bytes": 18939, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2afe7ebf4be418f461e4ef3b4b39b1728a7d9555eeb8c50cd5244179198d6cff" }, { "bytes": 8506, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cf6e3242bc94bc6e6f7eb6c27458e328d2746fdb93e05ba98bfe0f9a691afad5" }, { "bytes": 8149, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "824011483e3e7e6becc2e081de1c4e25239e673b8f0b8540f01f9ca6de9811bd" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089047/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089047", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7935-9bdf-16d79535ef15" } HiwH+SRzQm8CrRRzDs6zBls5ycsW1lK9niownOSet7v+3dXj+YuRzOBGg7u+Iqr03HjlghESbUNKTj+z8WxNAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: HiwH+SRzQm8CrRRzDs6zBls5ycsW1lK9niownOSet7v+3dXj+YuRzOBGg7u+Iqr03HjlghESbUNKTj+z8WxNAg== {"files":[{"bytes":18575,"name":"index.html","sha256":"d2c36b93dddbf21af75a9718f204bf4ffab7643a01732d71977ae85f91d3845b"},{"bytes":8185,"name":"publication.md","sha256":"cfe1ff75ecf248a64dc82e7d0bb1c76b3d5cda3f0956715a845346879cb3a80b"},{"bytes":7837,"name":"publication.txt","sha256":"88017849331c5af013af1494ce60489cfc99391a2eb45cd87d96810942873938"},{"bytes":2886,"name":"manifest.json","sha256":"4ce8751cb0bc4ebe4fa5c6bdf4fac0fcbc51926fd956fd20a598f54be5aa864b"},{"bytes":89,"name":"manifest.sig","sha256":"d2aa61dd63af1889b3dbc1c61f1abafd460b0f11579453ac9ea430d240112b87"},{"bytes":227,"name":"manifest.sig.txt","sha256":"48b9398cd0c921a6571ddfc81897bd42baecac1b88241d5dc5ade48cc929a7a4"}],"publication_id":"OT-2026-000089048"} Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089048
OpenTechnical

OT-2026-000089048

Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
88017849331c5af013af1494ce60489cfc99391a2eb45cd87d96810942873938

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089048, “Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089048.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089048" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089048" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089048 Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089048 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089048 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089048 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089048", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1136 }, "figures": [], "files": [ { "bytes": 18575, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d2c36b93dddbf21af75a9718f204bf4ffab7643a01732d71977ae85f91d3845b" }, { "bytes": 8185, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cfe1ff75ecf248a64dc82e7d0bb1c76b3d5cda3f0956715a845346879cb3a80b" }, { "bytes": 7837, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "88017849331c5af013af1494ce60489cfc99391a2eb45cd87d96810942873938" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089048/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089048", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7c71-9203-adcd2607bfd9" } 1Lh8KGXfEFnry74IdvlWxm9EhQ28IySG1NszYEHl421Q1DKYWDow3l0CVeIelePmWDEeWpQXgWGKtF4N8wWeAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 1Lh8KGXfEFnry74IdvlWxm9EhQ28IySG1NszYEHl421Q1DKYWDow3l0CVeIelePmWDEeWpQXgWGKtF4N8wWeAQ== {"files":[{"bytes":19381,"name":"index.html","sha256":"593c7edf16b89978e169854f0a4b05e593dfe41134eec4c96c940d9121d61b6b"},{"bytes":8873,"name":"publication.md","sha256":"1475ab0dcab0755a50d5c5025d3a55794533483e5dcb20fff948b9e11b6efd34"},{"bytes":8526,"name":"publication.txt","sha256":"7cd2ca98892581c96ae4e121ed5320be2490e85130bb995ad8bfffe504a7f77b"},{"bytes":2891,"name":"manifest.json","sha256":"874062429dea66342fc3e01dd13c4013ee703a18d7df1fb8a3c14f8b7750c3ca"},{"bytes":89,"name":"manifest.sig","sha256":"5135e36eb734ea2cb5d611873781eb9d9999fff5b896fe5236bb2272e169120e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2108fb38ae00b60fcd77f2914ac92d97ea6e45f93e693ee5a1edcb45cfaeccf8"}],"publication_id":"OT-2026-000089049"} Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089049
OpenTechnical

OT-2026-000089049

Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7cd2ca98892581c96ae4e121ed5320be2490e85130bb995ad8bfffe504a7f77b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089049, “Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089049.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089049" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089049" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089049 Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089049 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089049 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089049 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089049", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1242 }, "figures": [], "files": [ { "bytes": 19381, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "593c7edf16b89978e169854f0a4b05e593dfe41134eec4c96c940d9121d61b6b" }, { "bytes": 8873, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1475ab0dcab0755a50d5c5025d3a55794533483e5dcb20fff948b9e11b6efd34" }, { "bytes": 8526, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7cd2ca98892581c96ae4e121ed5320be2490e85130bb995ad8bfffe504a7f77b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089049/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089049", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-751a-a2dc-13ee164bb674" } ZYL1Gh1Tgwot1hEJPbzX5XQOIHX6MnL1HqJ7XRGmd/743vbZglFx5BOEkK1Q1IrdxemtdoHuTo+Auhxow7mHBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ZYL1Gh1Tgwot1hEJPbzX5XQOIHX6MnL1HqJ7XRGmd/743vbZglFx5BOEkK1Q1IrdxemtdoHuTo+Auhxow7mHBA== {"files":[{"bytes":19128,"name":"index.html","sha256":"3834f2f9bdac5725bf82af0019d48b4d28f568d8908227a3a3d916d3ba090855"},{"bytes":8663,"name":"publication.md","sha256":"b8185d89fa87bf0b802db9a0b151d999ab6de70d4068d7d1c7a974f3a2bd2b32"},{"bytes":8316,"name":"publication.txt","sha256":"f7082e5f81ffdd4554657eff39b87434137d2619c80fae0c1abf86f5af1ba2d0"},{"bytes":2891,"name":"manifest.json","sha256":"9567e8a508a557d83a30b0a2a041504b3f4e97e744ed2b49acff9ab145386f8c"},{"bytes":89,"name":"manifest.sig","sha256":"a86cc2269c3948d4ff52807a8f89a97eb53f5c29a16cf0df23689abf08d873cf"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a2abee1de7ce81fda55db5007abb2957639af87f6a0b4dd2dfeacc48e10f8be0"}],"publication_id":"OT-2026-000089050"} Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089050
OpenTechnical

OT-2026-000089050

Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f7082e5f81ffdd4554657eff39b87434137d2619c80fae0c1abf86f5af1ba2d0

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089050, “Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089050.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089050" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089050" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089050 Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089050 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089050 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089050 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089050", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1207 }, "figures": [], "files": [ { "bytes": 19128, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3834f2f9bdac5725bf82af0019d48b4d28f568d8908227a3a3d916d3ba090855" }, { "bytes": 8663, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b8185d89fa87bf0b802db9a0b151d999ab6de70d4068d7d1c7a974f3a2bd2b32" }, { "bytes": 8316, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f7082e5f81ffdd4554657eff39b87434137d2619c80fae0c1abf86f5af1ba2d0" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089050/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089050", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7a0b-ae5c-8d22e3ae8893" } GQq88pWFAXQ9Zz657RGSzKcuQnzptiYX31iDlQqC6oQVf+RPdQ8YsnfNFjJdIFH7SqQSex+yr/wOK3bJ6DHyAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: GQq88pWFAXQ9Zz657RGSzKcuQnzptiYX31iDlQqC6oQVf+RPdQ8YsnfNFjJdIFH7SqQSex+yr/wOK3bJ6DHyAA== {"files":[{"bytes":18521,"name":"index.html","sha256":"af8a284093988ffb0b9d2451adbaac129bcfe32676d5d0e215fabfda6eb5243b"},{"bytes":8131,"name":"publication.md","sha256":"e505b0c9e561b816c6d167178fe398e9eaace2dd0fa052f84bcb7bb054b92cc1"},{"bytes":7783,"name":"publication.txt","sha256":"160b3ef20550160ff2996386198712632b74b5fd6b6c1baeba99b2c1b86f46b7"},{"bytes":2886,"name":"manifest.json","sha256":"089754209fd11067f1d48afefdbcc84e71ebae81c910dad28acae966b636014a"},{"bytes":89,"name":"manifest.sig","sha256":"7ec2f6ed32ef819616702f124b8bf53d29d79df983300200b34bf7605b4cff1d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3f5626c813e82baf3a44cde8a54a5b4bd300162d14ed1e327a752d87d28dd6c0"}],"publication_id":"OT-2026-000089051"} Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089051
OpenTechnical

OT-2026-000089051

Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
160b3ef20550160ff2996386198712632b74b5fd6b6c1baeba99b2c1b86f46b7

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089051, “Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089051.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089051" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089051" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089051 Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089051 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089051 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089051 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089051", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1121 }, "figures": [], "files": [ { "bytes": 18521, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "af8a284093988ffb0b9d2451adbaac129bcfe32676d5d0e215fabfda6eb5243b" }, { "bytes": 8131, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e505b0c9e561b816c6d167178fe398e9eaace2dd0fa052f84bcb7bb054b92cc1" }, { "bytes": 7783, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "160b3ef20550160ff2996386198712632b74b5fd6b6c1baeba99b2c1b86f46b7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089051/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089051", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-75b0-9306-0a66a1ce0d68" } KW6SbmJsChV5sGre3lvvAbMljfLhaS5gyd7VEyB67NG84/JJOLnH0cpY7zMWMqYf1Ztx4QqF0g2RQp1qSx9vCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: KW6SbmJsChV5sGre3lvvAbMljfLhaS5gyd7VEyB67NG84/JJOLnH0cpY7zMWMqYf1Ztx4QqF0g2RQp1qSx9vCQ== {"files":[{"bytes":19327,"name":"index.html","sha256":"0bed0dbbd600a7fb552346d6b54ecd64cad20a7a32469e81768d081caefe4043"},{"bytes":8819,"name":"publication.md","sha256":"9e2f1eaebe6491c67d925dc6458b30e7b556fade6fd058836a2ac92468aeb44a"},{"bytes":8472,"name":"publication.txt","sha256":"0fac34a7263992273f34508434e8ceee93c171f017d492d38c10c71568147045"},{"bytes":2891,"name":"manifest.json","sha256":"8d72972f8346053b03dbb79962fa64d8815a4e4ccb58fda3406bb177cb0bb10d"},{"bytes":89,"name":"manifest.sig","sha256":"2e0886eb854af04095e8f9055b8c847816e669b50f212c32427c053ce365df38"},{"bytes":227,"name":"manifest.sig.txt","sha256":"16acabc22412bca3fedef7dae88fe16b64dcb18ef41e3426e3d7f9c672623328"}],"publication_id":"OT-2026-000089052"} Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089052
OpenTechnical

OT-2026-000089052

Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
0fac34a7263992273f34508434e8ceee93c171f017d492d38c10c71568147045

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089052, “Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089052.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089052" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089052" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089052 Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089052 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089052 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089052 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089052", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1227 }, "figures": [], "files": [ { "bytes": 19327, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0bed0dbbd600a7fb552346d6b54ecd64cad20a7a32469e81768d081caefe4043" }, { "bytes": 8819, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9e2f1eaebe6491c67d925dc6458b30e7b556fade6fd058836a2ac92468aeb44a" }, { "bytes": 8472, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0fac34a7263992273f34508434e8ceee93c171f017d492d38c10c71568147045" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089052/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089052", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7ba9-a24f-11ff5710ad20" } aRc3iEl9NgrvSR7B5cOj0EUfcF8LfmFVUD6PdiJxWUNDJ9R1nyT0liMTdm+Vit3tlUUJ/bEeil8mUuK217D9CA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: aRc3iEl9NgrvSR7B5cOj0EUfcF8LfmFVUD6PdiJxWUNDJ9R1nyT0liMTdm+Vit3tlUUJ/bEeil8mUuK217D9CA== {"files":[{"bytes":19074,"name":"index.html","sha256":"610146ff3051c40809d9b71e31ccd810a64bdcdd30b2556a398cefc75ba73fbb"},{"bytes":8609,"name":"publication.md","sha256":"f13040c2cd8ad59db84b55db4f084ff9ae89219b5b1585dfcefe592b729bb765"},{"bytes":8262,"name":"publication.txt","sha256":"9f14699adb875c30bec66e7f3e741093535605ba3db908b1cc32c77dd126ff46"},{"bytes":2891,"name":"manifest.json","sha256":"c674837a06ae266f42675fd4843b5ea448bcf6efc6178af04cd2aea4c60a86ab"},{"bytes":89,"name":"manifest.sig","sha256":"fa4cb8a13ed23cc7a01d5568f374f2ee957739f90f2808483f236848841ba441"},{"bytes":227,"name":"manifest.sig.txt","sha256":"865e7b2ea14975e946a776be6bdfd0da8ff5b464046a835c111070917a5dc2b9"}],"publication_id":"OT-2026-000089053"} Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089053
OpenTechnical

OT-2026-000089053

Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
9f14699adb875c30bec66e7f3e741093535605ba3db908b1cc32c77dd126ff46

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089053, “Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089053.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089053" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089053" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089053 Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089053 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089053 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089053 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089053", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1192 }, "figures": [], "files": [ { "bytes": 19074, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "610146ff3051c40809d9b71e31ccd810a64bdcdd30b2556a398cefc75ba73fbb" }, { "bytes": 8609, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f13040c2cd8ad59db84b55db4f084ff9ae89219b5b1585dfcefe592b729bb765" }, { "bytes": 8262, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9f14699adb875c30bec66e7f3e741093535605ba3db908b1cc32c77dd126ff46" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089053/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089053", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7a5d-9ea1-9cbe6b839d15" } lnqN7pqWzXS1jAAlNSQ7pldGGJyIBhemdmrgMMXUOKWkEHGtkv60lIpnaQwyHLZKaKuRTqOCVH5S6cls4ab1Bw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: lnqN7pqWzXS1jAAlNSQ7pldGGJyIBhemdmrgMMXUOKWkEHGtkv60lIpnaQwyHLZKaKuRTqOCVH5S6cls4ab1Bw== {"files":[{"bytes":18275,"name":"index.html","sha256":"d3d9111304f2b978e955736a266f5adf18bcd3e835b09f4cb052151a8ed59f95"},{"bytes":7933,"name":"publication.md","sha256":"12bbf2fd2769b94884652b3f9e02e64d3aee38fa104ccfa0c78e216ca420a05e"},{"bytes":7583,"name":"publication.txt","sha256":"dca9ef0906c967d0ab6934d8c45df3b007bf3a560247433012c079e7987ef976"},{"bytes":2899,"name":"manifest.json","sha256":"e55cd6f94ca016453012274e928b75bfc8973dd2524ae61bd9107bf4ed3ff01c"},{"bytes":89,"name":"manifest.sig","sha256":"1f58b2755d1b55a46e37cd0f269c3e4495ded44cdd0558943add69c8d3add02e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7b3a58aa4ef685d83bea324edaaa6845eb079312413c0dcfd2c34225931bccc6"}],"publication_id":"OT-2026-000089054"} Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089054
OpenTechnical

OT-2026-000089054

Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
dca9ef0906c967d0ab6934d8c45df3b007bf3a560247433012c079e7987ef976

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089054, “Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089054.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089054" title: "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089054" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089054 Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089054 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089054 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089054 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089054", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1084 }, "figures": [], "files": [ { "bytes": 18275, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d3d9111304f2b978e955736a266f5adf18bcd3e835b09f4cb052151a8ed59f95" }, { "bytes": 7933, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "12bbf2fd2769b94884652b3f9e02e64d3aee38fa104ccfa0c78e216ca420a05e" }, { "bytes": 7583, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "dca9ef0906c967d0ab6934d8c45df3b007bf3a560247433012c079e7987ef976" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089054/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089054", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7fc7-987b-55a4127afc26" } 1JB/tVeCWdw6x9EuMtbIFPd5N/nmWIt25KsD2IPiqgTXyjaVE9JqqL/VwGYXaJADSWPm5DFd7lEdNYpRf1CZCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 1JB/tVeCWdw6x9EuMtbIFPd5N/nmWIt25KsD2IPiqgTXyjaVE9JqqL/VwGYXaJADSWPm5DFd7lEdNYpRf1CZCQ== {"files":[{"bytes":19081,"name":"index.html","sha256":"cdcca4505e15eff16c9ee216ac393ccbc6026852123b5a99d1adabc1ddd79aa5"},{"bytes":8621,"name":"publication.md","sha256":"e9fc4d453ced71bc8bd67255e7a34faf0ad9ac2a3c0335070c976c88ea39cf8f"},{"bytes":8272,"name":"publication.txt","sha256":"916619cfd18d2d8c01f90269368c4c8153a1b843abd959dd068d74177138a186"},{"bytes":2904,"name":"manifest.json","sha256":"52ae0b1c648818085e7e3406eddc5a83e313c443c02262e439c77cf6e00d38ca"},{"bytes":89,"name":"manifest.sig","sha256":"a0336d622e76a9ffed28cd5949a427563e1bc4a133c17d777c13140c9ce501ef"},{"bytes":227,"name":"manifest.sig.txt","sha256":"384e6b9d86639a9e2851deb391be8e971e29e6a87a77db9538cb8ecc5cdf0b6e"}],"publication_id":"OT-2026-000089055"} Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089055
OpenTechnical

OT-2026-000089055

Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
916619cfd18d2d8c01f90269368c4c8153a1b843abd959dd068d74177138a186

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089055, “Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089055.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089055" title: "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089055" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089055 Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089055 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089055 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089055 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089055", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1190 }, "figures": [], "files": [ { "bytes": 19081, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "cdcca4505e15eff16c9ee216ac393ccbc6026852123b5a99d1adabc1ddd79aa5" }, { "bytes": 8621, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e9fc4d453ced71bc8bd67255e7a34faf0ad9ac2a3c0335070c976c88ea39cf8f" }, { "bytes": 8272, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "916619cfd18d2d8c01f90269368c4c8153a1b843abd959dd068d74177138a186" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089055/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089055", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-770b-90c1-c9ca3a225236" } mxU/uCHcX4kqpX5tnStvNEDa9ZTUN3mCziG2vpOQFKGqOp+t5xsPVYrxXGRHI3GSIqO7aq6x22rKsSPmSf1bCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: mxU/uCHcX4kqpX5tnStvNEDa9ZTUN3mCziG2vpOQFKGqOp+t5xsPVYrxXGRHI3GSIqO7aq6x22rKsSPmSf1bCw== {"files":[{"bytes":18828,"name":"index.html","sha256":"1aa81592df5918af029e1dc712c7c84d305290e92b3baf253ee5c7d2285fe73f"},{"bytes":8411,"name":"publication.md","sha256":"5fd68e5700360ec1e7f6502ac5b1192289ad5843dbf627e7b5be2b88c3902506"},{"bytes":8062,"name":"publication.txt","sha256":"6ba91e296ccfc4131a0d34cc7528baa1f8372d91fa23c8e91acd2907e5cdee93"},{"bytes":2904,"name":"manifest.json","sha256":"c11be976a67ca8f59f6c83eac3ef5fbfd7350e50e40d30db3389f336541bdd0e"},{"bytes":89,"name":"manifest.sig","sha256":"51a59f81eb7802e09948474f9c039a071ddd94ae2291c37d4aec8bf14a4b5180"},{"bytes":227,"name":"manifest.sig.txt","sha256":"fbb40f17579f81ac8bff8a44f883d93891e5d7284593240605eb950e829f3190"}],"publication_id":"OT-2026-000089056"} Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089056
OpenTechnical

OT-2026-000089056

Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
6ba91e296ccfc4131a0d34cc7528baa1f8372d91fa23c8e91acd2907e5cdee93

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089056, “Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089056.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089056" title: "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089056" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089056 Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089056 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089056 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089056 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089056", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1155 }, "figures": [], "files": [ { "bytes": 18828, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1aa81592df5918af029e1dc712c7c84d305290e92b3baf253ee5c7d2285fe73f" }, { "bytes": 8411, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5fd68e5700360ec1e7f6502ac5b1192289ad5843dbf627e7b5be2b88c3902506" }, { "bytes": 8062, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "6ba91e296ccfc4131a0d34cc7528baa1f8372d91fa23c8e91acd2907e5cdee93" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089056/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089056", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-731a-a760-7a57cc3a2c24" } 4aAmnG3MSRl2cDUjgZMF0zmV6rDtRwDbEglG500QG16VV684fsEjC1m0W69UURaPnIkgupRZBKqdIZY6LoVhBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 4aAmnG3MSRl2cDUjgZMF0zmV6rDtRwDbEglG500QG16VV684fsEjC1m0W69UURaPnIkgupRZBKqdIZY6LoVhBg== {"files":[{"bytes":18275,"name":"index.html","sha256":"c05b50d7c05f4ec3144649498d3e19c7fff856b9bbe725357aa8601e75782d6b"},{"bytes":7933,"name":"publication.md","sha256":"f20f418c0a95b8301b71854b113fde2f28b994fcb1b373107df598f2bd555b7d"},{"bytes":7583,"name":"publication.txt","sha256":"657e5f560eef3a9c5e2a1bb32f9f5e6f518b23430da96bcc572d0568bfb34f6c"},{"bytes":2899,"name":"manifest.json","sha256":"a568dd92ad09bc20d1c411a40956c2b3ead138976ecb1c0137291b3c0a28341f"},{"bytes":89,"name":"manifest.sig","sha256":"86a85f6b69b9a4db96c96e2a5704a9bfe03952bd8c5bd6a425b7138ccc5c5077"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a9454b1553b4deef1dd77a312da31697959bdf0626cbbdc37e5220c9d5f63486"}],"publication_id":"OT-2026-000089057"} Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089057
OpenTechnical

OT-2026-000089057

Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
657e5f560eef3a9c5e2a1bb32f9f5e6f518b23430da96bcc572d0568bfb34f6c

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089057, “Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089057.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089057" title: "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089057" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089057 Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089057 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089057 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089057 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089057", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1084 }, "figures": [], "files": [ { "bytes": 18275, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c05b50d7c05f4ec3144649498d3e19c7fff856b9bbe725357aa8601e75782d6b" }, { "bytes": 7933, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f20f418c0a95b8301b71854b113fde2f28b994fcb1b373107df598f2bd555b7d" }, { "bytes": 7583, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "657e5f560eef3a9c5e2a1bb32f9f5e6f518b23430da96bcc572d0568bfb34f6c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089057/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089057", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7b4c-95fc-b463b474e3da" } kteo2hG+ev4pZDndaYmK74YX1apWBthbxdz7RK6DSTqfdIb5prQSDL3vrH5kpvQiJcGxhqVEJ4bir1CNIr8TCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: kteo2hG+ev4pZDndaYmK74YX1apWBthbxdz7RK6DSTqfdIb5prQSDL3vrH5kpvQiJcGxhqVEJ4bir1CNIr8TCA== {"files":[{"bytes":19081,"name":"index.html","sha256":"99d1f3487f6b575beda1299b42a25b9886a3fcf16d7d82ae3af7036867367fd1"},{"bytes":8621,"name":"publication.md","sha256":"612d1396416e309c6b5c2e6cfdd36cc61b0c46f2237853d96ceec090e670e0ba"},{"bytes":8272,"name":"publication.txt","sha256":"0df356686ca3720bd53f3b1dc9d4f167a5c9c47c4345a74181049ea1681219aa"},{"bytes":2904,"name":"manifest.json","sha256":"b7da157f061c47052ab8becd8c22247b2eb9dc32ab52d2b7152124158595cd1c"},{"bytes":89,"name":"manifest.sig","sha256":"d629fa0dda535b2895046154df93b32e8f70bac9207c7280ab7375c3c1102ba0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"af2cacedfc3e1a7606fbe003ddf4e134985a0d83e3cc41a013bc5b7c061d89a3"}],"publication_id":"OT-2026-000089058"} Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089058
OpenTechnical

OT-2026-000089058

Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
0df356686ca3720bd53f3b1dc9d4f167a5c9c47c4345a74181049ea1681219aa

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089058, “Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089058.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089058" title: "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089058" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089058 Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089058 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089058 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089058 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089058", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1190 }, "figures": [], "files": [ { "bytes": 19081, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "99d1f3487f6b575beda1299b42a25b9886a3fcf16d7d82ae3af7036867367fd1" }, { "bytes": 8621, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "612d1396416e309c6b5c2e6cfdd36cc61b0c46f2237853d96ceec090e670e0ba" }, { "bytes": 8272, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0df356686ca3720bd53f3b1dc9d4f167a5c9c47c4345a74181049ea1681219aa" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089058/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089058", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7d75-ae24-729fe3973327" } QLhuGyawcMBg7DTrGBD4a4DAZcKl4+GJajyKvtHszQ6LKbDPPAywkd2ScYBkku5LoJcKGqojLOgVUjOSBXYYDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: QLhuGyawcMBg7DTrGBD4a4DAZcKl4+GJajyKvtHszQ6LKbDPPAywkd2ScYBkku5LoJcKGqojLOgVUjOSBXYYDQ== {"files":[{"bytes":18828,"name":"index.html","sha256":"deedca39ffc9c67205f9b1cea9bd3c5dca7f72cca1cb37e01a9ef2cb33856abb"},{"bytes":8411,"name":"publication.md","sha256":"a4584fded912ed09268e6486781ef84225b4bc833c9bd22fcc79ab44413daf15"},{"bytes":8062,"name":"publication.txt","sha256":"8c6e69fe4e67d8274aa76dd2270e090f8a66fc0ab6fddd039f56d024ad37a7b0"},{"bytes":2904,"name":"manifest.json","sha256":"c06d5035165719ff02c2b5e96f6b516dd3e9ad18e101076cfdd7bec5abf2ef6c"},{"bytes":89,"name":"manifest.sig","sha256":"f8c3aa6e609a25e5d88a4fdf244d3ff7bcfd9747047f3f3009e8c2994f6591f7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"fd899d6ca5f7c1ef56b0e522bf8968413bad5883ffb38b01d1c7bb631029fe2e"}],"publication_id":"OT-2026-000089059"} Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089059
OpenTechnical

OT-2026-000089059

Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8c6e69fe4e67d8274aa76dd2270e090f8a66fc0ab6fddd039f56d024ad37a7b0

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining four manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089059, “Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089059.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089059" title: "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089059" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089059 Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089059 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining four manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089059 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089059 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089059", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1155 }, "figures": [], "files": [ { "bytes": 18828, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "deedca39ffc9c67205f9b1cea9bd3c5dca7f72cca1cb37e01a9ef2cb33856abb" }, { "bytes": 8411, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a4584fded912ed09268e6486781ef84225b4bc833c9bd22fcc79ab44413daf15" }, { "bytes": 8062, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8c6e69fe4e67d8274aa76dd2270e090f8a66fc0ab6fddd039f56d024ad37a7b0" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089059/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089059", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7eb1-8a9b-868151650da1" } a4c5TSrJu1aM9fRVPQI+F59XKYl02XEiG0PC9n50Ad8XRHaAuKAIUDZQHYA00P95X6rl8DJyfbrMfiN1kjtlBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: a4c5TSrJu1aM9fRVPQI+F59XKYl02XEiG0PC9n50Ad8XRHaAuKAIUDZQHYA00P95X6rl8DJyfbrMfiN1kjtlBw== {"files":[{"bytes":18322,"name":"index.html","sha256":"545f46a240e68e3790ee00bc72594113e4c930d05825078c42ceffc85cb93cd5"},{"bytes":7921,"name":"publication.md","sha256":"2858bc2eb4c057581e4fcee1c8ce27bd37e99f7313abda66b069283827685d0c"},{"bytes":7590,"name":"publication.txt","sha256":"246fc1103e1a62c9e9e37f10bdbde0ae04c707fbf7da6c52b64de240852309bb"},{"bytes":2856,"name":"manifest.json","sha256":"d78d0643c0a6a1c381ce33ecf5f6e7ccfa2d35790bd9a1407d4fdf58b8a9899b"},{"bytes":89,"name":"manifest.sig","sha256":"bf76a12242ef920e4d7f156be08d99e29707c32d83ecbf469e5388985c30956c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"5a2cae2ee93f97a0b22efc4e5557b64f1ff78f538fbba9a7d7389d156d415208"}],"publication_id":"OT-2026-000089060"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089060
OpenTechnical

OT-2026-000089060

Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
246fc1103e1a62c9e9e37f10bdbde0ae04c707fbf7da6c52b64de240852309bb

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089060, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089060.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089060" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089060" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089060 Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089060 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089060 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089060 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089060", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1094 }, "figures": [], "files": [ { "bytes": 18322, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "545f46a240e68e3790ee00bc72594113e4c930d05825078c42ceffc85cb93cd5" }, { "bytes": 7921, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "2858bc2eb4c057581e4fcee1c8ce27bd37e99f7313abda66b069283827685d0c" }, { "bytes": 7590, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "246fc1103e1a62c9e9e37f10bdbde0ae04c707fbf7da6c52b64de240852309bb" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089060/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089060", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-77f4-a1eb-2caf734afe99" } ZcC58nciSKrrZVpQUtqjHcC4MSKT7SHLJ/m9ysmQ85wksTr6MTGayiGu6/to+95C63hT65aPo6mayJmSKSciBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ZcC58nciSKrrZVpQUtqjHcC4MSKT7SHLJ/m9ysmQ85wksTr6MTGayiGu6/to+95C63hT65aPo6mayJmSKSciBw== {"files":[{"bytes":19137,"name":"index.html","sha256":"57c8c58ffe0d138abd2cf61bcb7a42127c1f3aa6e126899fdbff0ba28687aff8"},{"bytes":8622,"name":"publication.md","sha256":"6f5889844a71fa5f09566831c77cf0446abb74bb9afdbee5c74777f4b3a2e8e1"},{"bytes":8285,"name":"publication.txt","sha256":"8c661335f5c1452beb3f9921b58a1e36f1ff71908e03543709580cf5d023e4ef"},{"bytes":2868,"name":"manifest.json","sha256":"1ccdd3427c04295eec0ae736a973246943f8c5c7353a78344019294221f48660"},{"bytes":89,"name":"manifest.sig","sha256":"bd5797272f42aa412d909c9bb5e74ea3343ace64650fe9d8e9d1527a83e16f5e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7b59adb944db605cb5f1e69ea2c6167b7f0d5fdff0d7a00bcb03bb0e92971794"}],"publication_id":"OT-2026-000089061"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089061
OpenTechnical

OT-2026-000089061

Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8c661335f5c1452beb3f9921b58a1e36f1ff71908e03543709580cf5d023e4ef

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089061, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089061.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089061" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089061" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089061 Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089061 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089061 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089061 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089061", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1200 }, "figures": [], "files": [ { "bytes": 19137, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "57c8c58ffe0d138abd2cf61bcb7a42127c1f3aa6e126899fdbff0ba28687aff8" }, { "bytes": 8622, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "6f5889844a71fa5f09566831c77cf0446abb74bb9afdbee5c74777f4b3a2e8e1" }, { "bytes": 8285, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8c661335f5c1452beb3f9921b58a1e36f1ff71908e03543709580cf5d023e4ef" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089061/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089061", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7820-91ef-29f1839dd793" } QdmVyCNajFOZVs0XSVm0N6ODBcJgSgOuSLpkOnSrpZoX+HQI39/lwzd+Sa88hesUfNww7OhoDvfgNcS/mkQADw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: QdmVyCNajFOZVs0XSVm0N6ODBcJgSgOuSLpkOnSrpZoX+HQI39/lwzd+Sa88hesUfNww7OhoDvfgNcS/mkQADw== {"files":[{"bytes":18884,"name":"index.html","sha256":"af2bdb04fb42ba7361a0ad4d5fe480c26ad99e110ecf3618918bd90e624d46bc"},{"bytes":8412,"name":"publication.md","sha256":"f029f908c26713af2de410a99c78aa68ee73fd021613559f18bafb70b754082d"},{"bytes":8075,"name":"publication.txt","sha256":"a0f601cb484d814644154e0806c591cd61f5160913d6997384068c413a1aa893"},{"bytes":2868,"name":"manifest.json","sha256":"23a6bff9df173883549c697da6f61cac6ad21fde84939a88809d1683024430ab"},{"bytes":89,"name":"manifest.sig","sha256":"67713add42703c26028a4adfd1ef9d037011ed384344583930839bba9887a741"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4c8b4d06ee46407955f3e29c67d89edf33d34537755448aeed864245d0e7dbe8"}],"publication_id":"OT-2026-000089062"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089062
OpenTechnical

OT-2026-000089062

Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a0f601cb484d814644154e0806c591cd61f5160913d6997384068c413a1aa893

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089062, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089062.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089062" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089062" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089062 Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089062 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089062 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089062 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089062", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1165 }, "figures": [], "files": [ { "bytes": 18884, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "af2bdb04fb42ba7361a0ad4d5fe480c26ad99e110ecf3618918bd90e624d46bc" }, { "bytes": 8412, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f029f908c26713af2de410a99c78aa68ee73fd021613559f18bafb70b754082d" }, { "bytes": 8075, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a0f601cb484d814644154e0806c591cd61f5160913d6997384068c413a1aa893" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089062/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089062", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-757a-99bb-f139e41831ca" } dJb2vZpiruP1Md0xt79nNoJpQKQ/qgZ4scBaS+3SGysp3FifYq4LPNZxH/z5wv6njLTxyRRJ6gSXwbykIetSCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: dJb2vZpiruP1Md0xt79nNoJpQKQ/qgZ4scBaS+3SGysp3FifYq4LPNZxH/z5wv6njLTxyRRJ6gSXwbykIetSCg== {"files":[{"bytes":18323,"name":"index.html","sha256":"623a09ecd4b4cbd3fbf8d9025886b33258443d38c84f88b73e3fe9c51ead7468"},{"bytes":7922,"name":"publication.md","sha256":"23e1028ad29e1ed0e79c9323d4562a63bdf4664c92e96ca103689f06fbd4f89f"},{"bytes":7591,"name":"publication.txt","sha256":"aff3438f9a10d24ec83182767d7eb9d22e982531563124e17536a913021aa222"},{"bytes":2856,"name":"manifest.json","sha256":"ab05f481f8b10ff54da7201868ea69259dee7357c817b7dcf0698a65be4875f6"},{"bytes":89,"name":"manifest.sig","sha256":"c52e414aaeb43c4e691353ae0c0561cf526a6074679c811058b98d6188d1486e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"703088a24bf3c42319ff8f070dc0c385b229c6eaad2fed7bbdcfcf397615aa93"}],"publication_id":"OT-2026-000089063"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089063
OpenTechnical

OT-2026-000089063

Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
aff3438f9a10d24ec83182767d7eb9d22e982531563124e17536a913021aa222

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089063, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089063.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089063" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089063" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089063 Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089063 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089063 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089063 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089063", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1094 }, "figures": [], "files": [ { "bytes": 18323, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "623a09ecd4b4cbd3fbf8d9025886b33258443d38c84f88b73e3fe9c51ead7468" }, { "bytes": 7922, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "23e1028ad29e1ed0e79c9323d4562a63bdf4664c92e96ca103689f06fbd4f89f" }, { "bytes": 7591, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "aff3438f9a10d24ec83182767d7eb9d22e982531563124e17536a913021aa222" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089063/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089063", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7395-926b-0c4e6cc1fed4" } k7qvvOTrJriHTmCu7p9RnuPDDB5iR5OU5v/uYafSKnGmxBuAdigIDX+rxHTfa1+SXr13BMvZqNsnLO3nQGT6Aw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: k7qvvOTrJriHTmCu7p9RnuPDDB5iR5OU5v/uYafSKnGmxBuAdigIDX+rxHTfa1+SXr13BMvZqNsnLO3nQGT6Aw== {"files":[{"bytes":19138,"name":"index.html","sha256":"b259fa91eac2c36e68fa7b9da43b4efa3b5ad08728547fbefc8c358b1cc30467"},{"bytes":8623,"name":"publication.md","sha256":"44c1bf4b5add85410c7a8eb951f913c0db9932de52a73dcb09c69d1523451381"},{"bytes":8286,"name":"publication.txt","sha256":"e23139bf098a1089c5b0777fcb7731893543ac299e4d364bcacdbd0a3d7791fd"},{"bytes":2868,"name":"manifest.json","sha256":"39fd5f682f92b5a05f91fb8deb37ba8f71972f904d1e2d8bd6d5ad274ac81add"},{"bytes":89,"name":"manifest.sig","sha256":"0b1904468bd9938d964a656bc6795c6b491ee6a38e5511493de2d3f67c8a34e0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b17c4c1fbbc076fdc84ee395d7f39ccdfa522d6d9060682a58cf9ba2d2a8e5da"}],"publication_id":"OT-2026-000089064"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089064
OpenTechnical

OT-2026-000089064

Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e23139bf098a1089c5b0777fcb7731893543ac299e4d364bcacdbd0a3d7791fd

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089064, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089064.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089064" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089064" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089064 Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089064 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089064 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089064 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089064", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1200 }, "figures": [], "files": [ { "bytes": 19138, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b259fa91eac2c36e68fa7b9da43b4efa3b5ad08728547fbefc8c358b1cc30467" }, { "bytes": 8623, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "44c1bf4b5add85410c7a8eb951f913c0db9932de52a73dcb09c69d1523451381" }, { "bytes": 8286, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e23139bf098a1089c5b0777fcb7731893543ac299e4d364bcacdbd0a3d7791fd" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089064/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089064", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7f48-ad96-dba6ea9475a3" } 3MklVpNIdlga/gBvEkTnqvmAx8nBFKwDDcQ8RuNX0jYbsuRs3O6VddYGnPCSHQpXtPxDSaAMwG+x6LvQ1oDuAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 3MklVpNIdlga/gBvEkTnqvmAx8nBFKwDDcQ8RuNX0jYbsuRs3O6VddYGnPCSHQpXtPxDSaAMwG+x6LvQ1oDuAg== {"files":[{"bytes":18885,"name":"index.html","sha256":"acde333b87e8dc9e6cbfa4c6ada37ddfb6ff713477ff323e19122e49125e7c9d"},{"bytes":8413,"name":"publication.md","sha256":"076cc95b256879bbdd818477519092d724e313f10fd5dab4b984bc345344377c"},{"bytes":8076,"name":"publication.txt","sha256":"51aecd34f67d41c76a8f3fda4af09d47dd052d7b9f4a3c1b95a3fbbaf0b6a0ec"},{"bytes":2868,"name":"manifest.json","sha256":"1312e21200b34d87c565fd4f6cb46ff5413d001f07df49d74f9e4bf7046003e7"},{"bytes":89,"name":"manifest.sig","sha256":"844d2a8f4e1e3ca70699580a5a9287c7b2b16c6f3c72a176ff52892b6fe91009"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b6e73cad6869afa9f81ac2b7f5d6f87d9ac740f4a4646c00d1b7f2b9d92b4e95"}],"publication_id":"OT-2026-000089065"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089065
OpenTechnical

OT-2026-000089065

Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
51aecd34f67d41c76a8f3fda4af09d47dd052d7b9f4a3c1b95a3fbbaf0b6a0ec

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089065, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089065.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089065" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089065" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089065 Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089065 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089065 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089065 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089065", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1165 }, "figures": [], "files": [ { "bytes": 18885, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "acde333b87e8dc9e6cbfa4c6ada37ddfb6ff713477ff323e19122e49125e7c9d" }, { "bytes": 8413, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "076cc95b256879bbdd818477519092d724e313f10fd5dab4b984bc345344377c" }, { "bytes": 8076, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "51aecd34f67d41c76a8f3fda4af09d47dd052d7b9f4a3c1b95a3fbbaf0b6a0ec" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089065/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089065", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7f64-a047-cb3202ae2dbc" } GrqlU1ftMlZnYdYssEnCHNBJXeoNjXS3N2JCF2Aj3Mb3d51ufjlJ0q6kpCkYOzgfCZE7PzGtDszdhntNMhlvBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: GrqlU1ftMlZnYdYssEnCHNBJXeoNjXS3N2JCF2Aj3Mb3d51ufjlJ0q6kpCkYOzgfCZE7PzGtDszdhntNMhlvBQ== {"files":[{"bytes":18327,"name":"index.html","sha256":"f925c4e3e85dd3d2a6cf9d0ffb16b7929180cf47300ef528ee80f83cf665e5b0"},{"bytes":7926,"name":"publication.md","sha256":"be208e8aa4aa89591e9e967c479d6d28f847c36a1cbc00d4e4971b0d50120f04"},{"bytes":7595,"name":"publication.txt","sha256":"721f409fd27eea31bf4c54273bdc7bb0d95a17261baae6bfc80d25878368fda5"},{"bytes":2856,"name":"manifest.json","sha256":"17504238dce6047c4917d35b6bca54ca4e41e07f917915e2e957af0f2b8266ba"},{"bytes":89,"name":"manifest.sig","sha256":"80142c0ef58e44e5f3ef6c0dd8071fca87ebbe6886393a47f19eb366290e9500"},{"bytes":227,"name":"manifest.sig.txt","sha256":"946aa2d19d9689f83e3912109a4e92373ced88d5b8956d00bb0a45c4f7240aa2"}],"publication_id":"OT-2026-000089066"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089066
OpenTechnical

OT-2026-000089066

Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
721f409fd27eea31bf4c54273bdc7bb0d95a17261baae6bfc80d25878368fda5

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089066, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089066.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089066" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089066" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089066 Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089066 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089066 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089066 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089066", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1094 }, "figures": [], "files": [ { "bytes": 18327, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f925c4e3e85dd3d2a6cf9d0ffb16b7929180cf47300ef528ee80f83cf665e5b0" }, { "bytes": 7926, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "be208e8aa4aa89591e9e967c479d6d28f847c36a1cbc00d4e4971b0d50120f04" }, { "bytes": 7595, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "721f409fd27eea31bf4c54273bdc7bb0d95a17261baae6bfc80d25878368fda5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089066/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089066", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7291-9fc9-851248799aa1" } ij/VGxeoPbZgn7C8EQdHpn0ib1hPKssA0kBQFFpMcmmnnOSULU8yjqjU6s8zfeElLC3ZInfm07/R+1zOJ0URAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ij/VGxeoPbZgn7C8EQdHpn0ib1hPKssA0kBQFFpMcmmnnOSULU8yjqjU6s8zfeElLC3ZInfm07/R+1zOJ0URAQ== {"files":[{"bytes":19142,"name":"index.html","sha256":"d75b0ccd1313d91ec87e04c84b41877eafdde568a80239111d17abe5d0906759"},{"bytes":8627,"name":"publication.md","sha256":"dabc1b18c90bedf6a7ff6e8a6cb9b5a4918d7126579db99503f390d6fec65c1e"},{"bytes":8290,"name":"publication.txt","sha256":"b64014acd96dd2189a26a93d7e9041ccd7155b4488b8ff5767e5dbdc9ae9c391"},{"bytes":2868,"name":"manifest.json","sha256":"24e97f40ba6a564abf08a9619b9e972edb845b33af7878165a42eebadbfd7ac7"},{"bytes":89,"name":"manifest.sig","sha256":"1c541ac30978d66c45ffd132fd2cea28b11d43e80255dfe9be99b118b5a15ed7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"750caa6486c411dd572a3585302d4b2d349fa5475ad012cef4480c00efb2e990"}],"publication_id":"OT-2026-000089067"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089067
OpenTechnical

OT-2026-000089067

Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
b64014acd96dd2189a26a93d7e9041ccd7155b4488b8ff5767e5dbdc9ae9c391

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089067, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089067.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089067" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089067" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089067 Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089067 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089067 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089067 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089067", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1200 }, "figures": [], "files": [ { "bytes": 19142, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d75b0ccd1313d91ec87e04c84b41877eafdde568a80239111d17abe5d0906759" }, { "bytes": 8627, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "dabc1b18c90bedf6a7ff6e8a6cb9b5a4918d7126579db99503f390d6fec65c1e" }, { "bytes": 8290, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b64014acd96dd2189a26a93d7e9041ccd7155b4488b8ff5767e5dbdc9ae9c391" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089067/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089067", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7083-b6fa-62671cd1a18d" } WgzeSARYxRax+al/eDmnDgcKGq4lEZIyWlTD6ILhIYlipxGSV06GDZ92J6OZPs7umOLSP2kOw3adjjn/Nb10BA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: WgzeSARYxRax+al/eDmnDgcKGq4lEZIyWlTD6ILhIYlipxGSV06GDZ92J6OZPs7umOLSP2kOw3adjjn/Nb10BA== {"files":[{"bytes":18889,"name":"index.html","sha256":"bec34abe683a8780dfd720ca13af91be9e26c31365b27e4dfda2165f04ecf80c"},{"bytes":8417,"name":"publication.md","sha256":"39fa386e2c72646204233b5854ab87706a916d2f5edac3903a99d6764faf96aa"},{"bytes":8080,"name":"publication.txt","sha256":"8247e1ea8232d70a24f1ea37cfd83e2b115cb88c715b62af62f7612d80d1e80c"},{"bytes":2868,"name":"manifest.json","sha256":"8b701b900848199dcd1119554ceb3a3469aacb4a7ea3adb6dec206f5280c58aa"},{"bytes":89,"name":"manifest.sig","sha256":"f857469aa10ebc15bb3188821de34ec51437a609420b12f005eec7ea3aacc9e1"},{"bytes":227,"name":"manifest.sig.txt","sha256":"fe095d59b26cf3c0c0ab311a0e419828caf0f12bc662a7b272100027dd190e79"}],"publication_id":"OT-2026-000089068"} Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089068
OpenTechnical

OT-2026-000089068

Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8247e1ea8232d70a24f1ea37cfd83e2b115cb88c715b62af62f7612d80d1e80c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089068, “Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089068.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089068" title: "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089068" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089068 Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089068 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089068 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089068 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089068", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1165 }, "figures": [], "files": [ { "bytes": 18889, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bec34abe683a8780dfd720ca13af91be9e26c31365b27e4dfda2165f04ecf80c" }, { "bytes": 8417, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "39fa386e2c72646204233b5854ab87706a916d2f5edac3903a99d6764faf96aa" }, { "bytes": 8080, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8247e1ea8232d70a24f1ea37cfd83e2b115cb88c715b62af62f7612d80d1e80c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089068/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089068", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-73da-a241-2d56f3826946" } NYTBTpLryapCpB93FPcIaxjPce9lc2OwMVn8z5E+O+n430XdDzGDOOAulYuIswxbpLSOL0aE14OSkqALaL0jBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: NYTBTpLryapCpB93FPcIaxjPce9lc2OwMVn8z5E+O+n430XdDzGDOOAulYuIswxbpLSOL0aE14OSkqALaL0jBA== {"files":[{"bytes":18516,"name":"index.html","sha256":"94106f86b25c1aaa957d05aee6943e70e36d39ead43b76088e89dcb3c9b05086"},{"bytes":8083,"name":"publication.md","sha256":"d914a26142b0f7b9f2618ee67e3c76bf2a102fccd5a4db4391b2b846373b00c4"},{"bytes":7762,"name":"publication.txt","sha256":"171e73d9c75fbe2aebc2d90e5e04dc82b4d7dbe9fe4b8e2bce329e0e2faf0a2c"},{"bytes":2835,"name":"manifest.json","sha256":"fe77cb38be223e3afc3780accddc2af16535b24328a730cb5005b1befd88dccf"},{"bytes":89,"name":"manifest.sig","sha256":"7785e891814e65dd2c532bede8487f83955e13fe9d80189a992b622c38161415"},{"bytes":227,"name":"manifest.sig.txt","sha256":"dee78cfa9a5bd892c33152e19337a30b5f0e8b4fb2e789d4921fa89ade3d6505"}],"publication_id":"OT-2026-000089069"} Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089069
OpenTechnical

OT-2026-000089069

Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
171e73d9c75fbe2aebc2d90e5e04dc82b4d7dbe9fe4b8e2bce329e0e2faf0a2c

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089069, “Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089069.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089069" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089069" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089069 Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089069 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089069 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089069 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089069", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1134 }, "figures": [], "files": [ { "bytes": 18516, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "94106f86b25c1aaa957d05aee6943e70e36d39ead43b76088e89dcb3c9b05086" }, { "bytes": 8083, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d914a26142b0f7b9f2618ee67e3c76bf2a102fccd5a4db4391b2b846373b00c4" }, { "bytes": 7762, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "171e73d9c75fbe2aebc2d90e5e04dc82b4d7dbe9fe4b8e2bce329e0e2faf0a2c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089069/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089069", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7ff6-ab34-16d81f7cbdf4" } Pa9UKNjX1KZzbEaW+Vs0NTI3EsIF8ai8XshsuqeSC8+zkq1+xtgIIT52x4ay0YFsrJRB4KqEY+ceowQ5uwGECg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Pa9UKNjX1KZzbEaW+Vs0NTI3EsIF8ai8XshsuqeSC8+zkq1+xtgIIT52x4ay0YFsrJRB4KqEY+ceowQ5uwGECg== {"files":[{"bytes":19331,"name":"index.html","sha256":"814eba04e5acd63f77322abd1921b996b90829dbeccf25d3dceadd8f58004de3"},{"bytes":8784,"name":"publication.md","sha256":"aab05b093427659eeeb7ad5d97275e623e1fd8d19af0a67c668eee0c451ec4cb"},{"bytes":8457,"name":"publication.txt","sha256":"fa9a6410bbb89311ed7f1e4289880f17925ea144cd00fbfd9dce0937065126f6"},{"bytes":2847,"name":"manifest.json","sha256":"cf8f60f7df658b23a533245b44eedd16673fc24aa5fdd32df8c76b123ebd6276"},{"bytes":89,"name":"manifest.sig","sha256":"81a8d0a9ff3a69afc884e2debc6806b0ac47ed7e729f84d4ca1e6f1a33a16ce8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9a4d36104eeeb6f61582858569eba7464bf0794b9bdc6469302724980c6fb5db"}],"publication_id":"OT-2026-000089070"} Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089070
OpenTechnical

OT-2026-000089070

Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
fa9a6410bbb89311ed7f1e4289880f17925ea144cd00fbfd9dce0937065126f6

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089070, “Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089070.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089070" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089070" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089070 Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089070 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089070 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089070 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089070", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1240 }, "figures": [], "files": [ { "bytes": 19331, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "814eba04e5acd63f77322abd1921b996b90829dbeccf25d3dceadd8f58004de3" }, { "bytes": 8784, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "aab05b093427659eeeb7ad5d97275e623e1fd8d19af0a67c668eee0c451ec4cb" }, { "bytes": 8457, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fa9a6410bbb89311ed7f1e4289880f17925ea144cd00fbfd9dce0937065126f6" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089070/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089070", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7b68-a5ee-35057f682c4f" } RFsvvAuaC0qRRdSdw6xadxHHLWBKSiM2kFI9qgzKlSR9sZMYHhyk3pf1bbQT4eYyNRZNjM9pxUjocYp3xoNdBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: RFsvvAuaC0qRRdSdw6xadxHHLWBKSiM2kFI9qgzKlSR9sZMYHhyk3pf1bbQT4eYyNRZNjM9pxUjocYp3xoNdBg== {"files":[{"bytes":19078,"name":"index.html","sha256":"8f617fd85cf9dc9ce585a0076694b809e44b81b4d6a2785afa3839897eb4ba36"},{"bytes":8574,"name":"publication.md","sha256":"831a6b04092e7f8633329006efaacda1c8ba4cd92da661c368626f29ba818660"},{"bytes":8247,"name":"publication.txt","sha256":"fd6cbc57aa5819fa309c0ca2727cdc864ff03dd5dd0aef61a75d036276a2692f"},{"bytes":2847,"name":"manifest.json","sha256":"a66624c2db1518207bde388931f4f53804ea37d9cce18054e8278a02a980da17"},{"bytes":89,"name":"manifest.sig","sha256":"6996756c972903d058a515b427f4c5ddbc2cba3cf4d04b5b3c403d080e19081f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"02c0e54ff727c893a7504bb9c0c4e04537d0db5dabceddca7e4518758a2a0c8d"}],"publication_id":"OT-2026-000089071"} Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089071
OpenTechnical

OT-2026-000089071

Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
fd6cbc57aa5819fa309c0ca2727cdc864ff03dd5dd0aef61a75d036276a2692f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089071, “Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089071.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089071" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089071" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089071 Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089071 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089071 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089071 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089071", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19078, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8f617fd85cf9dc9ce585a0076694b809e44b81b4d6a2785afa3839897eb4ba36" }, { "bytes": 8574, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "831a6b04092e7f8633329006efaacda1c8ba4cd92da661c368626f29ba818660" }, { "bytes": 8247, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fd6cbc57aa5819fa309c0ca2727cdc864ff03dd5dd0aef61a75d036276a2692f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089071/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089071", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7e5e-9bc4-cb01459a49f1" } bYDdNCYkZ2ymRX3fj6e1lsNW12X4b7+OvATr5lautonTx1cq6AVeQBdwXzeJWjLxKuOK+9PdqQrrZYQN4/ZfBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: bYDdNCYkZ2ymRX3fj6e1lsNW12X4b7+OvATr5lautonTx1cq6AVeQBdwXzeJWjLxKuOK+9PdqQrrZYQN4/ZfBQ== {"files":[{"bytes":18462,"name":"index.html","sha256":"1b83501e7860fad5487f9ac98885046190017e83068630ed2dd1872b9804e1e1"},{"bytes":8029,"name":"publication.md","sha256":"585360063a9378472f0deda0d8c171fd80927e43ae061118e1aba25696ec9883"},{"bytes":7708,"name":"publication.txt","sha256":"1af19321121667a1d99742425383a3258d89a054601c0c4f92035648ef527124"},{"bytes":2835,"name":"manifest.json","sha256":"ec573da9787fd92543d46b67ae566a033741c8fe5af6f8682704ba32e37ec30e"},{"bytes":89,"name":"manifest.sig","sha256":"ced824df5f1114034a37bfaab88c5b286e9c42acaf30bbe33cad8e7ef45b2945"},{"bytes":227,"name":"manifest.sig.txt","sha256":"96daaa9d95b6556499ac380a231b218f95222efef9f95156d596bd2408af3838"}],"publication_id":"OT-2026-000089072"} Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089072
OpenTechnical

OT-2026-000089072

Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
1af19321121667a1d99742425383a3258d89a054601c0c4f92035648ef527124

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089072, “Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089072.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089072" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089072" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089072 Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089072 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089072 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089072 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089072", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1119 }, "figures": [], "files": [ { "bytes": 18462, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1b83501e7860fad5487f9ac98885046190017e83068630ed2dd1872b9804e1e1" }, { "bytes": 8029, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "585360063a9378472f0deda0d8c171fd80927e43ae061118e1aba25696ec9883" }, { "bytes": 7708, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1af19321121667a1d99742425383a3258d89a054601c0c4f92035648ef527124" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089072/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089072", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7e04-a45a-f951952ae7d6" } qf7x90dd6gx+GheiIi/yXTzEXW/L1rXD+XPUmzItel+QN7iKguxVKdoqqzjoWdbFx8I4CnceVtyd/PSYLIiIDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: qf7x90dd6gx+GheiIi/yXTzEXW/L1rXD+XPUmzItel+QN7iKguxVKdoqqzjoWdbFx8I4CnceVtyd/PSYLIiIDg== {"files":[{"bytes":19277,"name":"index.html","sha256":"9bed51b351009709ea5f5bfaae5d3cb8eb3e790cd86ae0361301b08214952ff6"},{"bytes":8730,"name":"publication.md","sha256":"ef3ca4859bbc29c2f3ac4a600bc87b8d7d27a8f95d25702b7107b1bcebdda641"},{"bytes":8403,"name":"publication.txt","sha256":"3c9e798592211d352ec2904e7598cf9814d07f17bf8de17227c6e6fa25a440ad"},{"bytes":2847,"name":"manifest.json","sha256":"5e9b2362ab36bc10688544531db3989da5811da3df7d9c4ad2861985a8523079"},{"bytes":89,"name":"manifest.sig","sha256":"73747a6d939795ece0060c3696c6c4e18024fb1972bb44004bf69bbde4529b04"},{"bytes":227,"name":"manifest.sig.txt","sha256":"feacd604db33ebce25ce148830cab2dbef39b9ab99e1ec1017dc78342cb72925"}],"publication_id":"OT-2026-000089073"} Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089073
OpenTechnical

OT-2026-000089073

Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
3c9e798592211d352ec2904e7598cf9814d07f17bf8de17227c6e6fa25a440ad

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089073, “Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089073.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089073" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089073" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089073 Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089073 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089073 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089073 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089073", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1225 }, "figures": [], "files": [ { "bytes": 19277, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9bed51b351009709ea5f5bfaae5d3cb8eb3e790cd86ae0361301b08214952ff6" }, { "bytes": 8730, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ef3ca4859bbc29c2f3ac4a600bc87b8d7d27a8f95d25702b7107b1bcebdda641" }, { "bytes": 8403, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3c9e798592211d352ec2904e7598cf9814d07f17bf8de17227c6e6fa25a440ad" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089073/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089073", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7b8a-a366-1807126a1e5a" } lYOQcbiLSOAMus/xrReHJI9cfehtL9YKMwDfZwpUwpgbQEE3n48Gw/eV8I/BMTA+UO3GhsMsWKnASOYmt8V0CQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: lYOQcbiLSOAMus/xrReHJI9cfehtL9YKMwDfZwpUwpgbQEE3n48Gw/eV8I/BMTA+UO3GhsMsWKnASOYmt8V0CQ== {"files":[{"bytes":19024,"name":"index.html","sha256":"71827b283b508c1cb600104959115984690b0b1a40fcfc685b47b37de0be4e32"},{"bytes":8520,"name":"publication.md","sha256":"4b93619cac82c0efcedd7fb1f21b99384a89d915723ab1b8ee1bb7e11fb38f83"},{"bytes":8193,"name":"publication.txt","sha256":"80c9766fa79a45f3aa2ecce1af37f00af0dfaa305c24f4f777670092c8e4e32b"},{"bytes":2847,"name":"manifest.json","sha256":"e12c0e419eae504a926a2365dc5c6e4f97e71c79495d2e2bc1fb7c7167e20ff0"},{"bytes":89,"name":"manifest.sig","sha256":"f3970c333b00b9365ce58b0cfe607559f03a159a23bb9bb7ca3bd52d04b0f439"},{"bytes":227,"name":"manifest.sig.txt","sha256":"bc45537c450a301747fffacce8e26565e1e03a97d3b4e3a19f4f5b70ed7a0a5a"}],"publication_id":"OT-2026-000089074"} Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089074
OpenTechnical

OT-2026-000089074

Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
80c9766fa79a45f3aa2ecce1af37f00af0dfaa305c24f4f777670092c8e4e32b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089074, “Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089074.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089074" title: "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089074" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089074 Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089074 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089074 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089074 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089074", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1190 }, "figures": [], "files": [ { "bytes": 19024, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "71827b283b508c1cb600104959115984690b0b1a40fcfc685b47b37de0be4e32" }, { "bytes": 8520, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4b93619cac82c0efcedd7fb1f21b99384a89d915723ab1b8ee1bb7e11fb38f83" }, { "bytes": 8193, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "80c9766fa79a45f3aa2ecce1af37f00af0dfaa305c24f4f777670092c8e4e32b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089074/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089074", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7c57-bfaa-4e75783c9dc1" } mPX53u1mLSSBQZQsEbRIMjZiAboLzcmTpZDsh1tYpxM1a/WUJJ5VjYDAxrkTe9PlFyTWaNCm+/P1em/blBe0Dw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: mPX53u1mLSSBQZQsEbRIMjZiAboLzcmTpZDsh1tYpxM1a/WUJJ5VjYDAxrkTe9PlFyTWaNCm+/P1em/blBe0Dw== {"files":[{"bytes":18216,"name":"index.html","sha256":"b83c2d6aba658a21532afd127e8bc97e760d086edaa30b92fea72041217b06b9"},{"bytes":7831,"name":"publication.md","sha256":"a918340b8eee266c200292f1c493d93e7bb959873ddb41fe35d22c958dc6490f"},{"bytes":7508,"name":"publication.txt","sha256":"51e1b494834ee052c0a84d1b6a1910dce3459d78d6a4dc5206371c05cda5ac4c"},{"bytes":2848,"name":"manifest.json","sha256":"5ea7c0e1bc90a9becbe8704e3decebb4c796725258a9be291da5825ac04979b8"},{"bytes":89,"name":"manifest.sig","sha256":"1a5419e3a6ce26377c46e2b7beb8e00eee40ab145c4ae4b9b31128fc226e6ced"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7df31d070e9fec086aad72068615950da546ff23288dfa8733fbef642e4ee8ce"}],"publication_id":"OT-2026-000089075"} Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089075
OpenTechnical

OT-2026-000089075

Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
51e1b494834ee052c0a84d1b6a1910dce3459d78d6a4dc5206371c05cda5ac4c

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089075, “Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089075.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089075" title: "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089075" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089075 Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089075 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089075 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089075 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089075", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1082 }, "figures": [], "files": [ { "bytes": 18216, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b83c2d6aba658a21532afd127e8bc97e760d086edaa30b92fea72041217b06b9" }, { "bytes": 7831, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a918340b8eee266c200292f1c493d93e7bb959873ddb41fe35d22c958dc6490f" }, { "bytes": 7508, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "51e1b494834ee052c0a84d1b6a1910dce3459d78d6a4dc5206371c05cda5ac4c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089075/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089075", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7ed3-a966-8e7ad379d739" } 8WwwFiAgGAXKPTW1xNz4mwyd1wl723/wxYedDo8hRf990WlcZ46s+uhdqUNmZa/DPjzzwn4QY1purdOeiiiQAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 8WwwFiAgGAXKPTW1xNz4mwyd1wl723/wxYedDo8hRf990WlcZ46s+uhdqUNmZa/DPjzzwn4QY1purdOeiiiQAg== {"files":[{"bytes":19031,"name":"index.html","sha256":"659918ca2e119ab645ecb2565372664001353d9f3f4181b4b633357efeccf98f"},{"bytes":8532,"name":"publication.md","sha256":"f5a0f533cf8de4d37129d6cd7b5a2ea5024091891595d6fae7a87644a84eb6ef"},{"bytes":8203,"name":"publication.txt","sha256":"922e609a303353fe1a8829989369bc8688960f1c03d0980454f6e41d09648e93"},{"bytes":2860,"name":"manifest.json","sha256":"c0469010b690fb362628cab0915a5a4a0bfd483a5a409f87afd83299ee53bdbd"},{"bytes":89,"name":"manifest.sig","sha256":"d2c3ff570ee16c23729a7390a0444e5d50c2c0c8b55add0e4142df6240dd610e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e524f14aac96d8069fcb6457a421f828ba489b0c78689eab22eea3d1c5e3e55b"}],"publication_id":"OT-2026-000089076"} Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089076
OpenTechnical

OT-2026-000089076

Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
922e609a303353fe1a8829989369bc8688960f1c03d0980454f6e41d09648e93

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089076, “Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089076.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089076" title: "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089076" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089076 Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089076 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089076 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089076 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089076", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1188 }, "figures": [], "files": [ { "bytes": 19031, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "659918ca2e119ab645ecb2565372664001353d9f3f4181b4b633357efeccf98f" }, { "bytes": 8532, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f5a0f533cf8de4d37129d6cd7b5a2ea5024091891595d6fae7a87644a84eb6ef" }, { "bytes": 8203, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "922e609a303353fe1a8829989369bc8688960f1c03d0980454f6e41d09648e93" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089076/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089076", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-71d3-b732-e86915645e89" } 2YSE5jlMjt9zt37nEx/6APTvHloKrIhSkAQp8bEXpnxXb2PvMnaJjhf5RsxhsdbQ8Ut2oB5uAl9PXSwOosWjDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 2YSE5jlMjt9zt37nEx/6APTvHloKrIhSkAQp8bEXpnxXb2PvMnaJjhf5RsxhsdbQ8Ut2oB5uAl9PXSwOosWjDQ== {"files":[{"bytes":18778,"name":"index.html","sha256":"9dda72f9b1579a2e9bf001e1bfe98d8941e2ccc81d64a76ad5e56a4f0969be1a"},{"bytes":8322,"name":"publication.md","sha256":"4ce0a50048235cd4bd2ab7273ae9b01cd0a74e4eed4ebc361ed6359c93b25c9a"},{"bytes":7993,"name":"publication.txt","sha256":"cd2c0da9c7ca575935300608e296abcb8f90bac348b8e5846c2bdec4bfa84f86"},{"bytes":2860,"name":"manifest.json","sha256":"b4919d7b157869c3890ccf84e8a6a7a92e8ec8defd0871eedc22eb8adea65cae"},{"bytes":89,"name":"manifest.sig","sha256":"48975b57088145630b0c966b2584ea198b61f0c79413cca9401bb4ef20fb0bc8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"122c16cbbea4d9d9e3967d770481a232d8d4f91caa9bfbd1a56bfbab5947fb07"}],"publication_id":"OT-2026-000089077"} Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089077
OpenTechnical

OT-2026-000089077

Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cd2c0da9c7ca575935300608e296abcb8f90bac348b8e5846c2bdec4bfa84f86

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089077, “Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089077.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089077" title: "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089077" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089077 Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089077 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089077 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089077 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089077", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1153 }, "figures": [], "files": [ { "bytes": 18778, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9dda72f9b1579a2e9bf001e1bfe98d8941e2ccc81d64a76ad5e56a4f0969be1a" }, { "bytes": 8322, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4ce0a50048235cd4bd2ab7273ae9b01cd0a74e4eed4ebc361ed6359c93b25c9a" }, { "bytes": 7993, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cd2c0da9c7ca575935300608e296abcb8f90bac348b8e5846c2bdec4bfa84f86" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089077/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089077", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-77ca-aa88-19a147328fb8" } LzEs8R040USyrYZ0PUmu27BoGfM9NjtMYfkvFNcOjSqoqLIpH797DKwxi36sWzSCACZKvfoH83cTI8jn1nMuCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: LzEs8R040USyrYZ0PUmu27BoGfM9NjtMYfkvFNcOjSqoqLIpH797DKwxi36sWzSCACZKvfoH83cTI8jn1nMuCA== {"files":[{"bytes":18216,"name":"index.html","sha256":"ffc43b1ad07980fc3ebc19a8d6f8d02acda8bc11e08b94d8b4f3e5fe7a3c8065"},{"bytes":7831,"name":"publication.md","sha256":"dfc439cbae970282989f6f9775e4e93a1093dfc12216f815f2d69cec49a4ef91"},{"bytes":7508,"name":"publication.txt","sha256":"38de06c6b79564d43dc735ec4a08440ea02a235be66f788f13cc75dccd6b1010"},{"bytes":2848,"name":"manifest.json","sha256":"e20c3bf7f4148e65879a08b298a8cdb87ce9e027eabf99ed969e91b6985842f8"},{"bytes":89,"name":"manifest.sig","sha256":"bf04c2f77df2fa8aeb19b7512eb77cc02bfb9dd62f60a0c0b348e7ef41e23e5c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d5ef660765ea867c5b5deb8138b220224e0f083a6b18f9d5a8954b2742585ac4"}],"publication_id":"OT-2026-000089078"} Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089078
OpenTechnical

OT-2026-000089078

Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
38de06c6b79564d43dc735ec4a08440ea02a235be66f788f13cc75dccd6b1010

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089078, “Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089078.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089078" title: "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089078" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089078 Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089078 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089078 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089078 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089078", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1082 }, "figures": [], "files": [ { "bytes": 18216, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ffc43b1ad07980fc3ebc19a8d6f8d02acda8bc11e08b94d8b4f3e5fe7a3c8065" }, { "bytes": 7831, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "dfc439cbae970282989f6f9775e4e93a1093dfc12216f815f2d69cec49a4ef91" }, { "bytes": 7508, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "38de06c6b79564d43dc735ec4a08440ea02a235be66f788f13cc75dccd6b1010" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089078/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089078", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-78c9-b822-cd206224d7b4" } C6OZXqVRSIbRdubE9T5jesUsqTH+RlH/KLXH9JC1lhS1TWJkZ3Qk8jIhdDHwaN6elJjVflYBzD+co++RvaiBAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: C6OZXqVRSIbRdubE9T5jesUsqTH+RlH/KLXH9JC1lhS1TWJkZ3Qk8jIhdDHwaN6elJjVflYBzD+co++RvaiBAA== {"files":[{"bytes":19031,"name":"index.html","sha256":"7ce80148ad6d98b8cd789baa1f0f0e0dfa20e919eb517026acce2d4670b40331"},{"bytes":8532,"name":"publication.md","sha256":"4ac08de7cf301e5339e56ef9fa0d7d2702bafcebefd4c61b89be087f26cbd189"},{"bytes":8203,"name":"publication.txt","sha256":"dec507914e8d6f8954c4b9ad7f86ca10c129a32a0b54b4cb85942f8bf2a21eda"},{"bytes":2860,"name":"manifest.json","sha256":"0726683feaea0fdbc284f0aa3cd79149d8670cf2dfc6bbefd300315fe21c38cd"},{"bytes":89,"name":"manifest.sig","sha256":"909f66bb4a94645ac760e8c9f6bb893a95f74bebf94a1732427c026b59098d11"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2713fbe2b70b8f2b7b0c89227b2b311e72f5f43e72fd7d39cecc349c7d7ef0cf"}],"publication_id":"OT-2026-000089079"} Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089079
OpenTechnical

OT-2026-000089079

Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
dec507914e8d6f8954c4b9ad7f86ca10c129a32a0b54b4cb85942f8bf2a21eda

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089079, “Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089079.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089079" title: "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089079" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089079 Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089079 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089079 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089079 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089079", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1188 }, "figures": [], "files": [ { "bytes": 19031, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7ce80148ad6d98b8cd789baa1f0f0e0dfa20e919eb517026acce2d4670b40331" }, { "bytes": 8532, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4ac08de7cf301e5339e56ef9fa0d7d2702bafcebefd4c61b89be087f26cbd189" }, { "bytes": 8203, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "dec507914e8d6f8954c4b9ad7f86ca10c129a32a0b54b4cb85942f8bf2a21eda" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089079/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089079", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7c76-be3a-8cbb12bdcae4" } E16F1nrE7zDN61b9QQR8+si7RlA1J1JF9ifdtbuIM7NAW/31jh4YervO0/7zWNgpUiyfKzSg2iQgFekKiLZeDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: E16F1nrE7zDN61b9QQR8+si7RlA1J1JF9ifdtbuIM7NAW/31jh4YervO0/7zWNgpUiyfKzSg2iQgFekKiLZeDg== {"files":[{"bytes":18778,"name":"index.html","sha256":"b7b5eff8d8ce0521ccaa16c2f7f44f50f102db9fc02152ab7511c662ebca1a1e"},{"bytes":8322,"name":"publication.md","sha256":"786d6c46af79fbae314ae609fee199a2da762ef77b71c3953e11470320f7631c"},{"bytes":7993,"name":"publication.txt","sha256":"c7b94b17e18d414444cc65e4ae8d19af4796adfd6e3a4f18836336999e47266f"},{"bytes":2860,"name":"manifest.json","sha256":"118207eb0d67880181c298490bbb9eea722b52972e9fae22842cbae06d05b0af"},{"bytes":89,"name":"manifest.sig","sha256":"131292d3e2f145be3c008ba2acff307e94c048288789f342e6faf5ff2060a6e3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f1c3cf493bf11330231730fd2373ddfd36dba2ee603ed72194436897dcc21446"}],"publication_id":"OT-2026-000089080"} Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089080
OpenTechnical

OT-2026-000089080

Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c7b94b17e18d414444cc65e4ae8d19af4796adfd6e3a4f18836336999e47266f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining four manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089080, “Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089080.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089080" title: "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089080" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089080 Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089080 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining four manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089080 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089080 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089080", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1153 }, "figures": [], "files": [ { "bytes": 18778, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b7b5eff8d8ce0521ccaa16c2f7f44f50f102db9fc02152ab7511c662ebca1a1e" }, { "bytes": 8322, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "786d6c46af79fbae314ae609fee199a2da762ef77b71c3953e11470320f7631c" }, { "bytes": 7993, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c7b94b17e18d414444cc65e4ae8d19af4796adfd6e3a4f18836336999e47266f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089080/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089080", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7fee-86f4-785d28c1dd4e" } hGqGJfCkcc8+gR4YlZki3g4WWOROZqOZVuHFXxgRgw09r//Vwcez1iQg4Z8r/UqzoNO6vdP9/bDy2aX0NnHXBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: hGqGJfCkcc8+gR4YlZki3g4WWOROZqOZVuHFXxgRgw09r//Vwcez1iQg4Z8r/UqzoNO6vdP9/bDy2aX0NnHXBA== {"files":[{"bytes":18510,"name":"index.html","sha256":"23ebdf7df915808d444ccb9f017cc540a70c6546c47343f7b7462c74f5e2d903"},{"bytes":8073,"name":"publication.md","sha256":"4f5aa05ee101519bb9b0bbfa3fdff6133bdc868e5f95495921db4cbb8b866e9f"},{"bytes":7730,"name":"publication.txt","sha256":"93e12042455b8499c0a90110026095789ee041adfb381ca73310f19d8c4a8505"},{"bytes":2864,"name":"manifest.json","sha256":"b24dc2534a84c4d0d0d8576b4fc1044cf72c027dfd080a26352664e453113bc8"},{"bytes":89,"name":"manifest.sig","sha256":"dc2fca642eb10882cdcdf221bd5f42df1776e92eea5e003716a2985910fa7e62"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1c0e851094551923a4c8a45dd2bac2ff45513f823320d019b8962063b0716185"}],"publication_id":"OT-2026-000089081"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089081
OpenTechnical

OT-2026-000089081

Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
93e12042455b8499c0a90110026095789ee041adfb381ca73310f19d8c4a8505

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089081, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089081.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089081" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089081" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089081 Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089081 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089081 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089081 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089081", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18510, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "23ebdf7df915808d444ccb9f017cc540a70c6546c47343f7b7462c74f5e2d903" }, { "bytes": 8073, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4f5aa05ee101519bb9b0bbfa3fdff6133bdc868e5f95495921db4cbb8b866e9f" }, { "bytes": 7730, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "93e12042455b8499c0a90110026095789ee041adfb381ca73310f19d8c4a8505" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089081/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089081", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-793e-a585-3341fedab7fa" } xw09ckcA1pKQxPiT1zoVd5n8mS9EFAoI5Ifhz0Ton0vonI/MeEETxUkl+MpBinn1vg2uGnZivR/2g6mwWrBgDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: xw09ckcA1pKQxPiT1zoVd5n8mS9EFAoI5Ifhz0Ton0vonI/MeEETxUkl+MpBinn1vg2uGnZivR/2g6mwWrBgDQ== {"files":[{"bytes":19325,"name":"index.html","sha256":"c5db4a8dbffe33131250250cb98d0897d94294fb946209ff789c64d6e03097cb"},{"bytes":8774,"name":"publication.md","sha256":"921cbb72f9538cccf87dc339c980f932981d8280af9dc4a40634ac305e960314"},{"bytes":8425,"name":"publication.txt","sha256":"ccc37cd568e242f49f2146a4fc00096e560b064a287b38d94a8ad20b7676c5c1"},{"bytes":2876,"name":"manifest.json","sha256":"c7d484b46703765995deedc2fefab311c19b6ee5ac40c93ab32defa9e2905117"},{"bytes":89,"name":"manifest.sig","sha256":"2b4deebca2a62d3fc18c860d5a0802bbbd38c06eb979940252ec29bce871e044"},{"bytes":227,"name":"manifest.sig.txt","sha256":"684ef5380e1464bd306914af21848e47b4a484f05670930479f5b32134212cb4"}],"publication_id":"OT-2026-000089082"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089082
OpenTechnical

OT-2026-000089082

Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
ccc37cd568e242f49f2146a4fc00096e560b064a287b38d94a8ad20b7676c5c1

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089082, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089082.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089082" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089082" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089082 Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089082 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089082 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089082 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089082", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19325, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c5db4a8dbffe33131250250cb98d0897d94294fb946209ff789c64d6e03097cb" }, { "bytes": 8774, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "921cbb72f9538cccf87dc339c980f932981d8280af9dc4a40634ac305e960314" }, { "bytes": 8425, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ccc37cd568e242f49f2146a4fc00096e560b064a287b38d94a8ad20b7676c5c1" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089082/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089082", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7218-b42e-f14050daf3ce" } GooKe40sgRjGTbyPAg1RVH2KaSR3El5hNlA6lGsi3xATIR25hdxC7F9+vYxWcldKIelXdQx2f/Tl8Qt7EgUGBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: GooKe40sgRjGTbyPAg1RVH2KaSR3El5hNlA6lGsi3xATIR25hdxC7F9+vYxWcldKIelXdQx2f/Tl8Qt7EgUGBQ== {"files":[{"bytes":19072,"name":"index.html","sha256":"ed2cb22149ddf4aa7799d5b3628f9413802483c37683ed49718e123c52a17b11"},{"bytes":8564,"name":"publication.md","sha256":"9497d4064877d61045c3af89d2ed9171320174ec65285b6d36aaf451c07da558"},{"bytes":8215,"name":"publication.txt","sha256":"2348bb4cce4f75fcd4304bbe697e14a2461b157b2f91f9ef73abfff081adf8c5"},{"bytes":2876,"name":"manifest.json","sha256":"6ad06276173e9693653101c42c44d09f39ff3328e0b32cd3d92b48a6dad9eb10"},{"bytes":89,"name":"manifest.sig","sha256":"fa4abc9e7456127c0afbe42a446244eabaa4598e42a571a0a09425de4aa158cb"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9d54cf6a6b7802097cebd929e3e3ce004ebea31454c49a46c9122f27a5c62eb4"}],"publication_id":"OT-2026-000089083"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089083
OpenTechnical

OT-2026-000089083

Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
2348bb4cce4f75fcd4304bbe697e14a2461b157b2f91f9ef73abfff081adf8c5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089083, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089083.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089083" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089083" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089083 Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089083 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089083 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089083 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089083", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19072, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ed2cb22149ddf4aa7799d5b3628f9413802483c37683ed49718e123c52a17b11" }, { "bytes": 8564, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9497d4064877d61045c3af89d2ed9171320174ec65285b6d36aaf451c07da558" }, { "bytes": 8215, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2348bb4cce4f75fcd4304bbe697e14a2461b157b2f91f9ef73abfff081adf8c5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089083/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089083", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7b80-9df7-52dc03efc6ea" } cqZs/tdvOh997zWEV3CMyJBXYrBXmFILiMMkq9I7kxDOvLGW0xLLU5c6xjxjRkXCLzd4U4cH+iDwWUZcE6kGBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: cqZs/tdvOh997zWEV3CMyJBXYrBXmFILiMMkq9I7kxDOvLGW0xLLU5c6xjxjRkXCLzd4U4cH+iDwWUZcE6kGBw== {"files":[{"bytes":18511,"name":"index.html","sha256":"a2cee78791a32056b786fc93301e007306b002a1d16588c7af817cb3f88ff771"},{"bytes":8074,"name":"publication.md","sha256":"96c790fddc790de49891a4280fa3d650b81525ead7af9b0d8b3ad6ed35343407"},{"bytes":7731,"name":"publication.txt","sha256":"f19500567db6df25eaf623b012c3940b7662b1225161467d12ef80bb805bca1d"},{"bytes":2864,"name":"manifest.json","sha256":"a48866ac5ad5098c155f79b9360f3fc2cd5bf278d76deb2de37d75e786edbedd"},{"bytes":89,"name":"manifest.sig","sha256":"e279594bbd6328b997d4a4d0520c1ae9741b23c94d199b5fc901768ae92ed68d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9bf4031934d9483be925baca0dc675dec237797e5e8d02b3c43612be9bc0e8f7"}],"publication_id":"OT-2026-000089084"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089084
OpenTechnical

OT-2026-000089084

Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
f19500567db6df25eaf623b012c3940b7662b1225161467d12ef80bb805bca1d

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089084, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089084.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089084" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089084" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089084 Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089084 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089084 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089084 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089084", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18511, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a2cee78791a32056b786fc93301e007306b002a1d16588c7af817cb3f88ff771" }, { "bytes": 8074, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "96c790fddc790de49891a4280fa3d650b81525ead7af9b0d8b3ad6ed35343407" }, { "bytes": 7731, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f19500567db6df25eaf623b012c3940b7662b1225161467d12ef80bb805bca1d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089084/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089084", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7924-bd49-6ec613e43015" } rqPjBSVdYNFGCN0JydVrNtPLnH6vDQgKEGvr2nE0xZk+3OT+vq8yytfsHwrNNKCXncJMVz8CwS/zWssWCJ+QDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: rqPjBSVdYNFGCN0JydVrNtPLnH6vDQgKEGvr2nE0xZk+3OT+vq8yytfsHwrNNKCXncJMVz8CwS/zWssWCJ+QDg== {"files":[{"bytes":19326,"name":"index.html","sha256":"a368d5411aeebbd96bb72ff8b8797c29d51756ef62e27b02a3672d5d1adc2ac1"},{"bytes":8775,"name":"publication.md","sha256":"e87a1b50b9ee2bd625439cec7f1df9393f32a79238055e2f3beaedba774aef34"},{"bytes":8426,"name":"publication.txt","sha256":"216496c194915f48bfd83d4b47137720132285b5d973c8eec715ff91549f8380"},{"bytes":2876,"name":"manifest.json","sha256":"f57e77713453e4eb54feb774e43cafac505d0960f336b7264b5e8dd640a37648"},{"bytes":89,"name":"manifest.sig","sha256":"990fc3e7929fd4cb6c33444a3658c530ee170b1d2c3c6ff0e1fa4a362bab3266"},{"bytes":227,"name":"manifest.sig.txt","sha256":"5dd45b44ac682d0ef4927932714fc41308c2ac28f836a1f83324a517663f7fc6"}],"publication_id":"OT-2026-000089085"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089085
OpenTechnical

OT-2026-000089085

Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
216496c194915f48bfd83d4b47137720132285b5d973c8eec715ff91549f8380

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089085, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089085.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089085" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089085" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089085 Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089085 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089085 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089085 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089085", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19326, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a368d5411aeebbd96bb72ff8b8797c29d51756ef62e27b02a3672d5d1adc2ac1" }, { "bytes": 8775, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e87a1b50b9ee2bd625439cec7f1df9393f32a79238055e2f3beaedba774aef34" }, { "bytes": 8426, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "216496c194915f48bfd83d4b47137720132285b5d973c8eec715ff91549f8380" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089085/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089085", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-77bb-ac30-8078a787ca00" } vQMG2jm4apymEEm3D2b1St+LXjRiEStd+Nnw5shs4seTYBGRQa+FYZTZbYHcziLZmIdzxVZmbLxac7ZLXKBEDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: vQMG2jm4apymEEm3D2b1St+LXjRiEStd+Nnw5shs4seTYBGRQa+FYZTZbYHcziLZmIdzxVZmbLxac7ZLXKBEDg== {"files":[{"bytes":19073,"name":"index.html","sha256":"5e2b85e991271a883125ba5724e60a14e1d64c9202d1cfbf60c43e75f628485b"},{"bytes":8565,"name":"publication.md","sha256":"21769987b899489b687b8ce7d36137669703e3288633baf488c85b3c3384743c"},{"bytes":8216,"name":"publication.txt","sha256":"ad2c963335bc75f7131dfbf6cc36fdfafd2852967d79b11a2a60b41364bc5df7"},{"bytes":2876,"name":"manifest.json","sha256":"9b30768bff756daf264128109c6a0f0341a60d20d97498dd376530d955935743"},{"bytes":89,"name":"manifest.sig","sha256":"52c2c9e72104e60468dc399bdc65eb8b9872fbeee3fccfb4633bf70fcfcfd966"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0570cd27f4b205aef3bd7694bb2de2bdd7cbcde7269cc3dd1508d09f2deb077c"}],"publication_id":"OT-2026-000089086"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089086
OpenTechnical

OT-2026-000089086

Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
ad2c963335bc75f7131dfbf6cc36fdfafd2852967d79b11a2a60b41364bc5df7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089086, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089086.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089086" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089086" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089086 Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089086 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089086 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089086 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089086", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19073, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5e2b85e991271a883125ba5724e60a14e1d64c9202d1cfbf60c43e75f628485b" }, { "bytes": 8565, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "21769987b899489b687b8ce7d36137669703e3288633baf488c85b3c3384743c" }, { "bytes": 8216, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ad2c963335bc75f7131dfbf6cc36fdfafd2852967d79b11a2a60b41364bc5df7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089086/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089086", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7edd-a4d8-f439170096e4" } 8k6ndPrwBY48eWSacvGxDv/mHd2FSp5IrRqolciRkJIrIZUGZzBtmEKvllH4c2IsTNwVVo2dqFaPrg8ZFT7nCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 8k6ndPrwBY48eWSacvGxDv/mHd2FSp5IrRqolciRkJIrIZUGZzBtmEKvllH4c2IsTNwVVo2dqFaPrg8ZFT7nCg== {"files":[{"bytes":18515,"name":"index.html","sha256":"0c2aa2a7c772773d7f6653ed9d1806f2843f543f8803bdea0a494b99828f9c17"},{"bytes":8078,"name":"publication.md","sha256":"3a0012c438bf037e61259dbab7a2c57297557aa9924dd63cb70cbf4d8e9a5a79"},{"bytes":7735,"name":"publication.txt","sha256":"4c4ed3a0646eeb3fe1b303fca62e8a879b89b5dd6af8e6f68466cdad601ebe5f"},{"bytes":2864,"name":"manifest.json","sha256":"23572d4ce8af62e1dbfc54f6f99482e2b3049ec68abf52beb13fcfd55d67b3da"},{"bytes":89,"name":"manifest.sig","sha256":"c7333c1ba984d8d1cb23c606bda91d7c178261517a5bf967f3f5b9a0c2114a5f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"47aa9f87936d538df262123360f4aab0824f3baf7fe1269101d14e5133a67b56"}],"publication_id":"OT-2026-000089087"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089087
OpenTechnical

OT-2026-000089087

Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
4c4ed3a0646eeb3fe1b303fca62e8a879b89b5dd6af8e6f68466cdad601ebe5f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089087, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089087.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089087" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089087" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089087 Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089087 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089087 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089087 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089087", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18515, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0c2aa2a7c772773d7f6653ed9d1806f2843f543f8803bdea0a494b99828f9c17" }, { "bytes": 8078, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3a0012c438bf037e61259dbab7a2c57297557aa9924dd63cb70cbf4d8e9a5a79" }, { "bytes": 7735, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4c4ed3a0646eeb3fe1b303fca62e8a879b89b5dd6af8e6f68466cdad601ebe5f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089087/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089087", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-73d3-a66e-fab8add8047a" } n8BPiXl8l9RbgeFh5Ln1ZY+PKAobwV4cuNT4z2Dn83eGPuZGe5dhLN30DRFOJQpoj2J6GlxSq8t1oBrVlY5iAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: n8BPiXl8l9RbgeFh5Ln1ZY+PKAobwV4cuNT4z2Dn83eGPuZGe5dhLN30DRFOJQpoj2J6GlxSq8t1oBrVlY5iAw== {"files":[{"bytes":19330,"name":"index.html","sha256":"a95be8c2655c3f8bde23c7df424d996b09bf00176647c82f1198fa70868dc132"},{"bytes":8779,"name":"publication.md","sha256":"3b48d92df933c1e36603844437f21cd75f16b247c041e0ef5b24148b67a872b8"},{"bytes":8430,"name":"publication.txt","sha256":"a4d7af4265ed219e381221d7da61bd39d5fe627878ca35b69b089f589730fd17"},{"bytes":2876,"name":"manifest.json","sha256":"6273bfd95a1a7d5c8c749fef3e021eb7fcf44143967d94720a105581313c0a3d"},{"bytes":89,"name":"manifest.sig","sha256":"6826f42ea96137fc373ba4ea37489e735e1290b7fb7a6277b471ac35fc7b965a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ae07207093f5f47c2c576fed2c7fc87c28026c4a2c108062c779c6e17b19436b"}],"publication_id":"OT-2026-000089088"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089088
OpenTechnical

OT-2026-000089088

Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a4d7af4265ed219e381221d7da61bd39d5fe627878ca35b69b089f589730fd17

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089088, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089088.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089088" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089088" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089088 Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089088 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089088 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089088 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089088", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19330, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a95be8c2655c3f8bde23c7df424d996b09bf00176647c82f1198fa70868dc132" }, { "bytes": 8779, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3b48d92df933c1e36603844437f21cd75f16b247c041e0ef5b24148b67a872b8" }, { "bytes": 8430, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a4d7af4265ed219e381221d7da61bd39d5fe627878ca35b69b089f589730fd17" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089088/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089088", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7b58-a12e-241306870419" } PJkvo8h6iIuXcMfJndFw5hCxbgKZ8mh+qrK9fKkkDZVIaKB70hpM9IvQ87jaSpw/7NMjbMzKtwLtb5UCHf34CA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: PJkvo8h6iIuXcMfJndFw5hCxbgKZ8mh+qrK9fKkkDZVIaKB70hpM9IvQ87jaSpw/7NMjbMzKtwLtb5UCHf34CA== {"files":[{"bytes":19077,"name":"index.html","sha256":"e8d9e0059d40944c901b3babae27535e9c27aabd8fce7f1df826f3d638293826"},{"bytes":8569,"name":"publication.md","sha256":"342b44b5f86cc299c4c1a59af760db1bab6a25c6e171d3869d3b789e4624e6f8"},{"bytes":8220,"name":"publication.txt","sha256":"5b392419013e60d41ea3ea34847d87979cb609a68600c8a1ada9a36db21d5b71"},{"bytes":2876,"name":"manifest.json","sha256":"5cbd77bb055b884cf1f4a128961a44a6a6c25673fcb0d6cea1a3dd537b152506"},{"bytes":89,"name":"manifest.sig","sha256":"dd332b77f321bd22db083a5c6315b471093a1938fcc3869174d890f5c53b8d56"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7b5992b1c98bc9efc077ebd2971b2e11bf3c1baef47802b87428b23918047577"}],"publication_id":"OT-2026-000089089"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089089
OpenTechnical

OT-2026-000089089

Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
5b392419013e60d41ea3ea34847d87979cb609a68600c8a1ada9a36db21d5b71

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089089, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089089.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089089" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089089" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089089 Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089089 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089089 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089089 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089089", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19077, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "e8d9e0059d40944c901b3babae27535e9c27aabd8fce7f1df826f3d638293826" }, { "bytes": 8569, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "342b44b5f86cc299c4c1a59af760db1bab6a25c6e171d3869d3b789e4624e6f8" }, { "bytes": 8220, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5b392419013e60d41ea3ea34847d87979cb609a68600c8a1ada9a36db21d5b71" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089089/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089089", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7567-85ab-ffe05d3327e2" } zEdsdm9+0F1+GYjdtyJLfTrcTaEbVlPQWjfpodPvTPDduGooedkHz5TzE68r1zGYbRYoR7xDxEmxDrzigmIlDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: zEdsdm9+0F1+GYjdtyJLfTrcTaEbVlPQWjfpodPvTPDduGooedkHz5TzE68r1zGYbRYoR7xDxEmxDrzigmIlDw== {"files":[{"bytes":18688,"name":"index.html","sha256":"84e5d604007f89554a35f64c51fa1cee06accb91a609c2108ff4f7a6b7407b8b"},{"bytes":8223,"name":"publication.md","sha256":"ae5e1eec6454a198af7791108d847900224d9714a3bee52b1fdbaa7cdeaf8ee3"},{"bytes":7892,"name":"publication.txt","sha256":"2263d5ab341678db723a41b24ac7dc813a7323ab033731118ffa2cbc574bb4b1"},{"bytes":2839,"name":"manifest.json","sha256":"2dc421b81f0a9a47114504de3615727c8fbc9f346688a6420340faa5410f3360"},{"bytes":89,"name":"manifest.sig","sha256":"1e04abd7551b1d650e4fb63a54e356dce4ca1ab13e4c04958e391c35fd908e0d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"54be263c4b3c8f76879738991f5a95539994c2a6c3c35569a73b9c89dc9892b1"}],"publication_id":"OT-2026-000089090"} Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089090
OpenTechnical

OT-2026-000089090

Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
2263d5ab341678db723a41b24ac7dc813a7323ab033731118ffa2cbc574bb4b1

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089090, “Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089090.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089090" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089090" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089090 Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089090 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089090 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089090 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089090", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1151 }, "figures": [], "files": [ { "bytes": 18688, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "84e5d604007f89554a35f64c51fa1cee06accb91a609c2108ff4f7a6b7407b8b" }, { "bytes": 8223, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ae5e1eec6454a198af7791108d847900224d9714a3bee52b1fdbaa7cdeaf8ee3" }, { "bytes": 7892, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2263d5ab341678db723a41b24ac7dc813a7323ab033731118ffa2cbc574bb4b1" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089090/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089090", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7c66-aecb-5938d250a496" } +rvHBZQDC65W0PaKGd6UAGopLUhOIr5yRWV9Ra5mtSDI5eQXytNVkfKtZwETTHMmsxBdsmWHdQKIlbvNiIhtBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: +rvHBZQDC65W0PaKGd6UAGopLUhOIr5yRWV9Ra5mtSDI5eQXytNVkfKtZwETTHMmsxBdsmWHdQKIlbvNiIhtBQ== {"files":[{"bytes":19503,"name":"index.html","sha256":"8f801916cdf0c54379bd96ceaa96d7438fa64fd2d99856b0903b1239aed889fb"},{"bytes":8924,"name":"publication.md","sha256":"56fd476aa6f1f253798e509d823b572eb0e6b8620031fb1c7490c1785991f40d"},{"bytes":8587,"name":"publication.txt","sha256":"4daa27d26b6400dae2c582c2289ce32ebeb1d75c5f0bf38804b3e73c5e87ec79"},{"bytes":2851,"name":"manifest.json","sha256":"473c636dbd4f10e087a06e6a0e913e5fa40df3d33eb53f8b97ce67e944c30939"},{"bytes":89,"name":"manifest.sig","sha256":"1db917565eb1eb58af628d48fb7fe56e9f1ffa9c8efa5228290e68dbc539f87a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1a91a8c357975483f49ccca923ba1fe0a2015968caaedd38f4a33a0729994d1c"}],"publication_id":"OT-2026-000089091"} Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089091
OpenTechnical

OT-2026-000089091

Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
4daa27d26b6400dae2c582c2289ce32ebeb1d75c5f0bf38804b3e73c5e87ec79

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089091, “Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089091.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089091" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089091" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089091 Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089091 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089091 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089091 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089091", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1257 }, "figures": [], "files": [ { "bytes": 19503, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8f801916cdf0c54379bd96ceaa96d7438fa64fd2d99856b0903b1239aed889fb" }, { "bytes": 8924, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "56fd476aa6f1f253798e509d823b572eb0e6b8620031fb1c7490c1785991f40d" }, { "bytes": 8587, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4daa27d26b6400dae2c582c2289ce32ebeb1d75c5f0bf38804b3e73c5e87ec79" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089091/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089091", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7160-a019-4eb0fa6d2c14" } Ohd7u7F9ncKybOPilrpWyNbk2EqE/IAUbYzI5+zDAzWJ4yIHpeka8wHto/TbgJPPjhJZhLYi/q+HVF3gPGCqCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Ohd7u7F9ncKybOPilrpWyNbk2EqE/IAUbYzI5+zDAzWJ4yIHpeka8wHto/TbgJPPjhJZhLYi/q+HVF3gPGCqCw== {"files":[{"bytes":19250,"name":"index.html","sha256":"4e286b828b01437eb18ec1174ad4e5ee14f9ff2329b742b634b838027ce1d95a"},{"bytes":8714,"name":"publication.md","sha256":"cd4f612f2546592a1ae95cb521fb9538b256533b83a960e40a98208e7d318762"},{"bytes":8377,"name":"publication.txt","sha256":"826c508323fe0240953e1e68bb5c068c19620c8b453d620004eb4423b943e92b"},{"bytes":2851,"name":"manifest.json","sha256":"6fc06a5a5b0eca2b3615b14f1c5a53e8b08c302b04258fec5c7e9c2aac66186d"},{"bytes":89,"name":"manifest.sig","sha256":"53a402756a334e37f432c021c76e5bda58bb737e0d452ac51d1d347456fdd40a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1519d22276616f2cb777f0ad36301b9a0e7eb49b3b694164f44f56d73d9223d3"}],"publication_id":"OT-2026-000089092"} Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089092
OpenTechnical

OT-2026-000089092

Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
826c508323fe0240953e1e68bb5c068c19620c8b453d620004eb4423b943e92b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089092, “Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089092.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089092" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089092" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089092 Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089092 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089092 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089092 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089092", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1222 }, "figures": [], "files": [ { "bytes": 19250, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4e286b828b01437eb18ec1174ad4e5ee14f9ff2329b742b634b838027ce1d95a" }, { "bytes": 8714, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cd4f612f2546592a1ae95cb521fb9538b256533b83a960e40a98208e7d318762" }, { "bytes": 8377, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "826c508323fe0240953e1e68bb5c068c19620c8b453d620004eb4423b943e92b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089092/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089092", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7f24-9af1-52aeda159503" } Cgzn3UCtl4/26d5tq4+b86iXIGefWJPlG1sco7xKEFhL6TkPeLsoKFP3C7mIualaxUNYPBp73XfhAerSvOQyBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Cgzn3UCtl4/26d5tq4+b86iXIGefWJPlG1sco7xKEFhL6TkPeLsoKFP3C7mIualaxUNYPBp73XfhAerSvOQyBQ== {"files":[{"bytes":18634,"name":"index.html","sha256":"3c15442e83131cf602df3c7636e9da726e4aa8447591a059e52d75e0b2f643f6"},{"bytes":8169,"name":"publication.md","sha256":"bf0b8291e26d63aaab328fe4f155b49524f6abcd0f44b23679a03418518929a0"},{"bytes":7838,"name":"publication.txt","sha256":"4ece4aded4bb32819f91008860a407410feef239257550f166aeeeee1cc78958"},{"bytes":2839,"name":"manifest.json","sha256":"dd1880565bf1062cb29da3112a6a75f4ad186162d6ca803cd41aab9b14a1f2fb"},{"bytes":89,"name":"manifest.sig","sha256":"7c5532d98609610ce0544cdc2ad55faa7b9ca6373f082230155d2c115104bda0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d42240fb4494d1e6857d3a6c30e22bb978cdea4af37d044e4a3701662dae770c"}],"publication_id":"OT-2026-000089093"} Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089093
OpenTechnical

OT-2026-000089093

Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
4ece4aded4bb32819f91008860a407410feef239257550f166aeeeee1cc78958

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089093, “Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089093.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089093" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089093" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089093 Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089093 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089093 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089093 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089093", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1136 }, "figures": [], "files": [ { "bytes": 18634, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3c15442e83131cf602df3c7636e9da726e4aa8447591a059e52d75e0b2f643f6" }, { "bytes": 8169, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "bf0b8291e26d63aaab328fe4f155b49524f6abcd0f44b23679a03418518929a0" }, { "bytes": 7838, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4ece4aded4bb32819f91008860a407410feef239257550f166aeeeee1cc78958" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089093/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089093", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7619-a6c9-361472cb9d61" } EDskJ/2O6rNA//WwdCjOLwasCqOoIqzjfteVIRXH79M6wKd0u+DIbax7jWGrCgaL+s+9DnfVyKFD/IxzgfqCAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: EDskJ/2O6rNA//WwdCjOLwasCqOoIqzjfteVIRXH79M6wKd0u+DIbax7jWGrCgaL+s+9DnfVyKFD/IxzgfqCAQ== {"files":[{"bytes":19449,"name":"index.html","sha256":"4aee41c5ae44622972e3c19aee53784f9c91a549de6d282e97171a5dd58919dc"},{"bytes":8870,"name":"publication.md","sha256":"8c44677fc43f8bbdcc4a76e13d43e76f799ce9f7017ef24a9c27f0d607d66806"},{"bytes":8533,"name":"publication.txt","sha256":"d87049e7e40cc60309200ea52284401d84d49e30336a8ca86068c90374706c20"},{"bytes":2851,"name":"manifest.json","sha256":"9932d9fa587232f8e8b2563e6ab2ab7ebafed4a16c1b13a1f5fa7ba6e0f66dbe"},{"bytes":89,"name":"manifest.sig","sha256":"968e47054eb8c8ba9715dd65aa15192147903a0ccf08cc793d32b6be31de6e11"},{"bytes":227,"name":"manifest.sig.txt","sha256":"aeae162058a633aae6f8f5f8bfbc7f8c96017e8a9c4fe202db968855a75f30da"}],"publication_id":"OT-2026-000089094"} Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089094
OpenTechnical

OT-2026-000089094

Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
d87049e7e40cc60309200ea52284401d84d49e30336a8ca86068c90374706c20

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089094, “Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089094.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089094" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089094" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089094 Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089094 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089094 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089094 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089094", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1242 }, "figures": [], "files": [ { "bytes": 19449, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4aee41c5ae44622972e3c19aee53784f9c91a549de6d282e97171a5dd58919dc" }, { "bytes": 8870, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8c44677fc43f8bbdcc4a76e13d43e76f799ce9f7017ef24a9c27f0d607d66806" }, { "bytes": 8533, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d87049e7e40cc60309200ea52284401d84d49e30336a8ca86068c90374706c20" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089094/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089094", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-759d-b5f2-536fc860d2ba" } bAmH1Kw5XPG+stExpuIJ5Ffsj1k/mpTQ1kEE0jie4KOJcSs4TX64p2UXtAWHWto62PcJA7CXtOE4NqhbD8ekAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: bAmH1Kw5XPG+stExpuIJ5Ffsj1k/mpTQ1kEE0jie4KOJcSs4TX64p2UXtAWHWto62PcJA7CXtOE4NqhbD8ekAA== {"files":[{"bytes":19196,"name":"index.html","sha256":"46912866c5de920a23ba4f77580cc6b732c1438a8b07a662f4a21e4794ef0db0"},{"bytes":8660,"name":"publication.md","sha256":"df44377611b19aee1bca7351688f045ae8545594be1157dc382d74a1386cd806"},{"bytes":8323,"name":"publication.txt","sha256":"82c6776224c8d88671e65ea33fd27a398d34863926dafba2e0934a3938194ada"},{"bytes":2851,"name":"manifest.json","sha256":"87acdbfe63dad45450b4981e786c5864bba36118ae256838ede54c26309527c8"},{"bytes":89,"name":"manifest.sig","sha256":"27ac55ae32c8b2326cf091fbdcb8d531a90b5343856ca1a79b461f9bdf49855f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"dd20a3838136ec6be43ecb947d29bd83e92e3b35600f2dae8425c814252565af"}],"publication_id":"OT-2026-000089095"} Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089095
OpenTechnical

OT-2026-000089095

Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
82c6776224c8d88671e65ea33fd27a398d34863926dafba2e0934a3938194ada

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089095, “Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089095.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089095" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089095" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089095 Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089095 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089095 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089095 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089095", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1207 }, "figures": [], "files": [ { "bytes": 19196, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "46912866c5de920a23ba4f77580cc6b732c1438a8b07a662f4a21e4794ef0db0" }, { "bytes": 8660, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "df44377611b19aee1bca7351688f045ae8545594be1157dc382d74a1386cd806" }, { "bytes": 8323, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "82c6776224c8d88671e65ea33fd27a398d34863926dafba2e0934a3938194ada" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089095/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089095", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-77f6-83c4-31de2403a71c" } xDVfXYBss0srQZ4FIhWLUqa0GKpIbSbRyTaAvUjAYjTT6ajeLfSfM+928GPJroIHVXaWBc+JbQBUzRPw+v0zCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: xDVfXYBss0srQZ4FIhWLUqa0GKpIbSbRyTaAvUjAYjTT6ajeLfSfM+928GPJroIHVXaWBc+JbQBUzRPw+v0zCg== {"files":[{"bytes":18404,"name":"index.html","sha256":"c504c2b22adf2b04aada41aeb5e624ae88d55dd6b8286674226c637d883c7c9f"},{"bytes":7983,"name":"publication.md","sha256":"f4ea5512b8cc2595a1f850e64042180d139dc8f4690fe22d7b583bb8b63103d6"},{"bytes":7648,"name":"publication.txt","sha256":"d87374dc04ef7f17d284027a66cdc6fde33961c954a99fe381e7559858eaeccf"},{"bytes":2856,"name":"manifest.json","sha256":"4430b40445a3a62e98a9c3f1a406bc095d5886af04b7481326616dd5d499dec8"},{"bytes":89,"name":"manifest.sig","sha256":"ff51b6943179d3269d38b90efce81b4b817f975ef55ee9df4764b16ab3f36a7d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"cbaac21aede1adf2bcebdf2ce0e38fa0b8dbb7b7469cb67aa90d882bb1dcaf33"}],"publication_id":"OT-2026-000089096"} Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089096
OpenTechnical

OT-2026-000089096

Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
d87374dc04ef7f17d284027a66cdc6fde33961c954a99fe381e7559858eaeccf

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089096, “Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089096.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089096" title: "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089096" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089096 Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089096 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089096 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089096 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089096", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18404, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c504c2b22adf2b04aada41aeb5e624ae88d55dd6b8286674226c637d883c7c9f" }, { "bytes": 7983, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f4ea5512b8cc2595a1f850e64042180d139dc8f4690fe22d7b583bb8b63103d6" }, { "bytes": 7648, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d87374dc04ef7f17d284027a66cdc6fde33961c954a99fe381e7559858eaeccf" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089096/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089096", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7928-a8c0-10b9b168e2f3" } x/w+SJSWtOmdSZEA2pxNkcvduwphpfri8NARLLZhtpDsqQAmw1iq6lWr3FXMhkWt164VIt24cnUmq/Tm9g4DAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: x/w+SJSWtOmdSZEA2pxNkcvduwphpfri8NARLLZhtpDsqQAmw1iq6lWr3FXMhkWt164VIt24cnUmq/Tm9g4DAw== {"files":[{"bytes":19219,"name":"index.html","sha256":"3a6d1c74baad468c99c673ba58a33a9c9fb30e4c661e789781225f7d80f48eea"},{"bytes":8684,"name":"publication.md","sha256":"08080dc576845938b8900a76df495bcd05a51a2612830442c70a08382fb46e3e"},{"bytes":8343,"name":"publication.txt","sha256":"2bfc27e26b2d41e8489dcc0b9064f6be27cecd5b52a33d0f71baa16a76ac2021"},{"bytes":2868,"name":"manifest.json","sha256":"f4227a61dca17eb0f9a770b23fda4d43bc07735229c9fc987daa999f566fe275"},{"bytes":89,"name":"manifest.sig","sha256":"294f8ae41c8774de19ac9f74b3569ebcdaaf23728b46ba3c1fc86f2e1a226943"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0e431fdefab96af7d1a1352116d1ecf97118dec86d51fb6d83b4d7914550b4ba"}],"publication_id":"OT-2026-000089097"} Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089097
OpenTechnical

OT-2026-000089097

Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
2bfc27e26b2d41e8489dcc0b9064f6be27cecd5b52a33d0f71baa16a76ac2021

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089097, “Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089097.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089097" title: "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089097" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089097 Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089097 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089097 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089097 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089097", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19219, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3a6d1c74baad468c99c673ba58a33a9c9fb30e4c661e789781225f7d80f48eea" }, { "bytes": 8684, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "08080dc576845938b8900a76df495bcd05a51a2612830442c70a08382fb46e3e" }, { "bytes": 8343, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2bfc27e26b2d41e8489dcc0b9064f6be27cecd5b52a33d0f71baa16a76ac2021" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089097/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089097", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7502-887d-4ce079ab0fdb" } rV2gEJv5JT9fHvqtMdim1uQ5K4np4/SRjGqxJxx6ZQaJe4pM1Xk86l5h/Lefik8Ym6EReEL4onmMd+Cb4SPzBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: rV2gEJv5JT9fHvqtMdim1uQ5K4np4/SRjGqxJxx6ZQaJe4pM1Xk86l5h/Lefik8Ym6EReEL4onmMd+Cb4SPzBg== {"files":[{"bytes":18966,"name":"index.html","sha256":"023036d66d5b35d9634e272e83797efb954449cee60ba3c196d1193775b40855"},{"bytes":8474,"name":"publication.md","sha256":"a3a743a6fb1596400781f007c641f4251216746cfed2dd246a29d590619a2a87"},{"bytes":8133,"name":"publication.txt","sha256":"3949952963938e90f360a295e91b8c30976bb451e037ab0ff617aa97878ca34d"},{"bytes":2868,"name":"manifest.json","sha256":"1048494a958d5e7078033274b5376111083ffd8a00a5c03b3c60f833fa22b97c"},{"bytes":89,"name":"manifest.sig","sha256":"813f713316ab40cbc8567513281c3a67770345c11a8d9340efb452751a6138e7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a0c9ac3ff199e9129e2c619dac12852fa0937c835c3849c9e942294bd1397367"}],"publication_id":"OT-2026-000089098"} Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089098
OpenTechnical

OT-2026-000089098

Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
3949952963938e90f360a295e91b8c30976bb451e037ab0ff617aa97878ca34d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089098, “Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089098.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089098" title: "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089098" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089098 Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089098 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089098 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089098 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089098", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18966, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "023036d66d5b35d9634e272e83797efb954449cee60ba3c196d1193775b40855" }, { "bytes": 8474, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a3a743a6fb1596400781f007c641f4251216746cfed2dd246a29d590619a2a87" }, { "bytes": 8133, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3949952963938e90f360a295e91b8c30976bb451e037ab0ff617aa97878ca34d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089098/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089098", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-76ed-91eb-fb1faf2f6357" } 0EeASH2oLDT0xcNvjNDXFswdR+SzC9/N07pbf/JHUn0mpJgJywadU/3yirZ7SXAZHtKfmOiHM/7UVHv2DteIDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 0EeASH2oLDT0xcNvjNDXFswdR+SzC9/N07pbf/JHUn0mpJgJywadU/3yirZ7SXAZHtKfmOiHM/7UVHv2DteIDQ== {"files":[{"bytes":18404,"name":"index.html","sha256":"46563e1521910e50a0653ede17667e4abfb8c18a6f50e0bde527a390715b94b3"},{"bytes":7983,"name":"publication.md","sha256":"b1728f0284bfb173bf733ceec27181d5eb12f142aa2089263b72e3503fd8a959"},{"bytes":7648,"name":"publication.txt","sha256":"9876328a88a684a52a605afff97b67ebbc5538824531af38de0e1ddde1f9565d"},{"bytes":2856,"name":"manifest.json","sha256":"b1bc737a36fd2227c34954d889a388a959482cbf2267401d4c98bc4924a72e02"},{"bytes":89,"name":"manifest.sig","sha256":"49b1bbad35a64bc819b9cd11f8e68b5908fa6272c68f09816bc166f3a8e6cbad"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0d3facdafcf8a0df13f79a2337895f4a48c0ccf4331ed087084c311b1a0f20de"}],"publication_id":"OT-2026-000089099"} Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089099
OpenTechnical

OT-2026-000089099

Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
9876328a88a684a52a605afff97b67ebbc5538824531af38de0e1ddde1f9565d

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089099, “Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089099.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089099" title: "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089099" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089099 Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089099 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089099 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089099 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089099", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18404, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "46563e1521910e50a0653ede17667e4abfb8c18a6f50e0bde527a390715b94b3" }, { "bytes": 7983, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b1728f0284bfb173bf733ceec27181d5eb12f142aa2089263b72e3503fd8a959" }, { "bytes": 7648, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9876328a88a684a52a605afff97b67ebbc5538824531af38de0e1ddde1f9565d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089099/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089099", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-756e-bc86-01a641e96894" } 59GzRrUYBK+VbfQiT8++ZK0FY9vCl0xUMLw7Rh44/v/qJ9YH6DfzzBupudGdFaxcLz8HkDsmPGOyfQaWLa0TAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 59GzRrUYBK+VbfQiT8++ZK0FY9vCl0xUMLw7Rh44/v/qJ9YH6DfzzBupudGdFaxcLz8HkDsmPGOyfQaWLa0TAA== {"files":[{"bytes":19219,"name":"index.html","sha256":"e5a723a7c12c852cc36cda377a598418e9a07a88349426c2d73e68b777350169"},{"bytes":8684,"name":"publication.md","sha256":"676c2e2590d71f74f81fcd5009f072a07469f20fd54bbe45357d36284985a8be"},{"bytes":8343,"name":"publication.txt","sha256":"fdce49838cb68161f5c0668b1e5db7eaf6f212d839fe8f3a7a53b8452496b9c0"},{"bytes":2868,"name":"manifest.json","sha256":"b8a4c1ca6c8c721a351954714ce088d35e54c2c743417fe37ab452d5e5104569"},{"bytes":89,"name":"manifest.sig","sha256":"a7e30c3947e437530ad6333782158e636b6bc4dde9f35ac519c058510b4ca3ed"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8f8f6f5695a9874bfaf9e772585aba86056eb9c716d0c3fdf1cfd330cbeaad6e"}],"publication_id":"OT-2026-000089100"} Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089100
OpenTechnical

OT-2026-000089100

Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
fdce49838cb68161f5c0668b1e5db7eaf6f212d839fe8f3a7a53b8452496b9c0

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089100, “Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089100.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089100" title: "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089100" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089100 Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089100 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089100 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089100 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089100", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19219, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "e5a723a7c12c852cc36cda377a598418e9a07a88349426c2d73e68b777350169" }, { "bytes": 8684, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "676c2e2590d71f74f81fcd5009f072a07469f20fd54bbe45357d36284985a8be" }, { "bytes": 8343, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fdce49838cb68161f5c0668b1e5db7eaf6f212d839fe8f3a7a53b8452496b9c0" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089100/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089100", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-79a7-9a23-6023c4d18a18" } W0of7ZAtmH+Q8eCSV+FS5ZcsO2eCqBF2nRe09ZlBnIiEEv4kK/Q0HKohICQdUnU+B2ybn4MHtClS0efxRpC7CA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: W0of7ZAtmH+Q8eCSV+FS5ZcsO2eCqBF2nRe09ZlBnIiEEv4kK/Q0HKohICQdUnU+B2ybn4MHtClS0efxRpC7CA== {"files":[{"bytes":18966,"name":"index.html","sha256":"27b0004fd08c95c854e82300475a3e8512d521e4ec8cd85b1f64b578b542e6e6"},{"bytes":8474,"name":"publication.md","sha256":"9364efa8a858aef8d712b6a52ce12af75f24b6eb60b69d5cdd81b4a460794b0a"},{"bytes":8133,"name":"publication.txt","sha256":"9427309e7830a5a07cb91b66555ac068e261919adab9b1e7235406d3d7e69360"},{"bytes":2868,"name":"manifest.json","sha256":"13be86f814a231d52dbfa130515abf038c28042c416d74105c3f25bc551b1483"},{"bytes":89,"name":"manifest.sig","sha256":"fc8b894432f95ac4b1ca816a57b2bc232d93e01210d98843493c2b1059cb80eb"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f1404f2b5d0db38ca51867451cd7ac55a69a2dba87f47588024a52e2e3af108b"}],"publication_id":"OT-2026-000089101"} Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089101
OpenTechnical

OT-2026-000089101

Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
9427309e7830a5a07cb91b66555ac068e261919adab9b1e7235406d3d7e69360

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089101, “Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089101.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089101" title: "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089101" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089101 Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089101 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089101 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089101 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089101", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18966, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "27b0004fd08c95c854e82300475a3e8512d521e4ec8cd85b1f64b578b542e6e6" }, { "bytes": 8474, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9364efa8a858aef8d712b6a52ce12af75f24b6eb60b69d5cdd81b4a460794b0a" }, { "bytes": 8133, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9427309e7830a5a07cb91b66555ac068e261919adab9b1e7235406d3d7e69360" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089101/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089101", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-77a5-8066-14a67c39cc2b" } NKRQYd4zvXYCNynW3pc2C5LzKgGCA6O2MoOZ+nHxqwj9ariiuwIvmkPuubZlb+mCdq5CANQ4NZITTjCSNA0PBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: NKRQYd4zvXYCNynW3pc2C5LzKgGCA6O2MoOZ+nHxqwj9ariiuwIvmkPuubZlb+mCdq5CANQ4NZITTjCSNA0PBw== {"files":[{"bytes":18499,"name":"index.html","sha256":"2ea9d92e1ba364e7e36a1551244078db10dc07eb734c9c10af39649208aa9bc0"},{"bytes":8068,"name":"publication.md","sha256":"7102f19ff82e8c1a9eacb296563d2aa57cb2fc9906112fa8441de8039f02aa00"},{"bytes":7728,"name":"publication.txt","sha256":"075cd3256d321c2a387ff9f56809cecab9971b6660cb4a5a5868713fe226bd8a"},{"bytes":2861,"name":"manifest.json","sha256":"3979aaedc5a789e3e9911e5efd729ee441f51c53c1550b29eaa4109f76fb8870"},{"bytes":89,"name":"manifest.sig","sha256":"a34b17d03dfb22940b86e97e66b0ccb686df97dc7108cabcfcd4bad1949379fd"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e9093e784f666e375d65127fb283095af06b311100c43c6e2eddf1ffae917804"}],"publication_id":"OT-2026-000089102"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089102
OpenTechnical

OT-2026-000089102

Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
075cd3256d321c2a387ff9f56809cecab9971b6660cb4a5a5868713fe226bd8a

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089102, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089102.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089102" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089102" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089102 Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089102 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089102 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089102 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089102", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18499, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2ea9d92e1ba364e7e36a1551244078db10dc07eb734c9c10af39649208aa9bc0" }, { "bytes": 8068, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7102f19ff82e8c1a9eacb296563d2aa57cb2fc9906112fa8441de8039f02aa00" }, { "bytes": 7728, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "075cd3256d321c2a387ff9f56809cecab9971b6660cb4a5a5868713fe226bd8a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089102/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089102", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-734a-8acc-d178019d18cb" } 1yDxNyGKWXI32oTsl3HVAM9dUZMu/eIglLNkE19D3T0Bk16kJLopneA+Aqnz6VJCBxcgxAqlr0JuUPrHz0W8AQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 1yDxNyGKWXI32oTsl3HVAM9dUZMu/eIglLNkE19D3T0Bk16kJLopneA+Aqnz6VJCBxcgxAqlr0JuUPrHz0W8AQ== {"files":[{"bytes":19314,"name":"index.html","sha256":"2bb51043ee14e39c66212cb07392c69ea9f84007628f443945f1c27486ceae16"},{"bytes":8769,"name":"publication.md","sha256":"fb2e8a40cae7d76dfee703e4df83718c88d5195435e2dc7637c140e68f456fbe"},{"bytes":8423,"name":"publication.txt","sha256":"7af1fc73eb9c0576b251a67c01e4cf8589f2111b5c508eb1e8af2a5e9a1fe2cd"},{"bytes":2873,"name":"manifest.json","sha256":"22c8fe22f2ba7b0dda3a8e831af9c931faedea9bcdd664008049d140e2e23384"},{"bytes":89,"name":"manifest.sig","sha256":"f38e59cec837e8951621405c9dcf65e3c56fce5873fd23d033dbc5f085c8380c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"806ce1cbb8fa4f80d43428a2d10228c4edf50b36139cbb8bb8352e09d1246009"}],"publication_id":"OT-2026-000089103"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089103
OpenTechnical

OT-2026-000089103

Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7af1fc73eb9c0576b251a67c01e4cf8589f2111b5c508eb1e8af2a5e9a1fe2cd

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089103, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089103.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089103" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089103" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089103 Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089103 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089103 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089103 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089103", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19314, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2bb51043ee14e39c66212cb07392c69ea9f84007628f443945f1c27486ceae16" }, { "bytes": 8769, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fb2e8a40cae7d76dfee703e4df83718c88d5195435e2dc7637c140e68f456fbe" }, { "bytes": 8423, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7af1fc73eb9c0576b251a67c01e4cf8589f2111b5c508eb1e8af2a5e9a1fe2cd" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089103/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089103", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7d2c-95fa-004b799d8ad5" } T/oelOekSjhgbf1KeGWejkezyY/a2BhYAym6vXUb0AhQIDqRT0SeXWJnkBgvWXWVcsVHtR9CePdk0qm3YcFpAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: T/oelOekSjhgbf1KeGWejkezyY/a2BhYAym6vXUb0AhQIDqRT0SeXWJnkBgvWXWVcsVHtR9CePdk0qm3YcFpAg== {"files":[{"bytes":19061,"name":"index.html","sha256":"6ba81f830bb731118ad1e10d1e35f4146aec61eec8815cfdbcfc20d71a1db930"},{"bytes":8559,"name":"publication.md","sha256":"6e1e1ac1751a9c13fedcdd1124edfb34f704e87a911fb012df5e10c7b6f39c2c"},{"bytes":8213,"name":"publication.txt","sha256":"33ed424690e19560c17623cd867965c575220638abd0482c9a20a2f4cb3e7860"},{"bytes":2873,"name":"manifest.json","sha256":"ceb5bd3b081287e27ac46a09a9e87cb4652e07e243a625c147c10ae4ca426195"},{"bytes":89,"name":"manifest.sig","sha256":"6fabedf4ee24723db79ff1e20504520f5da27368ce2ac5dbae1716e41476dc3f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1709fcb77f0e3e5314553fa14fde9c70ce0d81ff7b4af159c4900670f344a50d"}],"publication_id":"OT-2026-000089104"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089104
OpenTechnical

OT-2026-000089104

Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
33ed424690e19560c17623cd867965c575220638abd0482c9a20a2f4cb3e7860

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089104, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089104.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089104" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089104" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089104 Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089104 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089104 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089104 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089104", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19061, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6ba81f830bb731118ad1e10d1e35f4146aec61eec8815cfdbcfc20d71a1db930" }, { "bytes": 8559, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "6e1e1ac1751a9c13fedcdd1124edfb34f704e87a911fb012df5e10c7b6f39c2c" }, { "bytes": 8213, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "33ed424690e19560c17623cd867965c575220638abd0482c9a20a2f4cb3e7860" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089104/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089104", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7d7d-90ff-f1cf07b81c85" } /XGaw2EwmEf3Nyzez967GCxFNJKoH1i17eD8LmzbsnZ733g7S2slJ5wZO1UpCgGKtht7nU9jLdfTb+q15NuQAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: /XGaw2EwmEf3Nyzez967GCxFNJKoH1i17eD8LmzbsnZ733g7S2slJ5wZO1UpCgGKtht7nU9jLdfTb+q15NuQAA== {"files":[{"bytes":18500,"name":"index.html","sha256":"1e9880f9798e0ba926a019e42ac589508d37a82bca5344278a2ab48866bb4199"},{"bytes":8069,"name":"publication.md","sha256":"c5ce89157bb27ed0346d5d19f525fcdf9b0951f160296754b149b4dd3b540493"},{"bytes":7729,"name":"publication.txt","sha256":"903cbcd41904e75fd803f6b849fcbada649e21d5f607cdb8e293d15483a4e3bb"},{"bytes":2861,"name":"manifest.json","sha256":"c8358ceb6215e85a0fae2dfabdd8902c652204163f3a09fa4940836e6b32776f"},{"bytes":89,"name":"manifest.sig","sha256":"6ea397eb080a0f5e095b198a30e083d28dfdfe9950fc0952a5e31284a8d1cb0b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d87fb95180baee24f45d0a4e04b1912d50519b9e2df3a97e445a99f34b41bb76"}],"publication_id":"OT-2026-000089105"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089105
OpenTechnical

OT-2026-000089105

Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
903cbcd41904e75fd803f6b849fcbada649e21d5f607cdb8e293d15483a4e3bb

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089105, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089105.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089105" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089105" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089105 Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089105 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089105 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089105 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089105", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18500, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1e9880f9798e0ba926a019e42ac589508d37a82bca5344278a2ab48866bb4199" }, { "bytes": 8069, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c5ce89157bb27ed0346d5d19f525fcdf9b0951f160296754b149b4dd3b540493" }, { "bytes": 7729, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "903cbcd41904e75fd803f6b849fcbada649e21d5f607cdb8e293d15483a4e3bb" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089105/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089105", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-70f2-8c39-9db8083cfc1e" } zx6XGoCluLvnnYjsWdHUTHSk3XJtxmymh9CHZ8UkBrcVYWY+Y/l9ZL15ugApm9AGvvUArKvjTQD0/n9fl3+IBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: zx6XGoCluLvnnYjsWdHUTHSk3XJtxmymh9CHZ8UkBrcVYWY+Y/l9ZL15ugApm9AGvvUArKvjTQD0/n9fl3+IBQ== {"files":[{"bytes":19315,"name":"index.html","sha256":"7d2e5dbb2412ba15386cd985f6fb64f440b301efe5270d57051e606fa57fa76d"},{"bytes":8770,"name":"publication.md","sha256":"214b90db58cf65f0a5164a0e8c4ef0360881b2ff11f34e245f49f5decb5dc300"},{"bytes":8424,"name":"publication.txt","sha256":"64f14e57bb11c2f4957d59bc21746931b7476252e6cc19f666397dea03159057"},{"bytes":2873,"name":"manifest.json","sha256":"b31475544830380d159785154801b96902bc58d12bde3fb176255611c8dc2feb"},{"bytes":89,"name":"manifest.sig","sha256":"b1f60a694a53100137acb91353dd59a21f7d0075a700c8edf9402c1cb346ac04"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3a60dfa1939a7bc540e1a88d895ba91829b5a36b247475583dc62c350db179b0"}],"publication_id":"OT-2026-000089106"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089106
OpenTechnical

OT-2026-000089106

Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
64f14e57bb11c2f4957d59bc21746931b7476252e6cc19f666397dea03159057

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089106, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089106.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089106" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089106" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089106 Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089106 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089106 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089106 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089106", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19315, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7d2e5dbb2412ba15386cd985f6fb64f440b301efe5270d57051e606fa57fa76d" }, { "bytes": 8770, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "214b90db58cf65f0a5164a0e8c4ef0360881b2ff11f34e245f49f5decb5dc300" }, { "bytes": 8424, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "64f14e57bb11c2f4957d59bc21746931b7476252e6cc19f666397dea03159057" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089106/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089106", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7356-9ae7-14749fae9d60" } NKqx9R4/H15HpRU5WhiwSGy4XZ/7p2Lrm5ohptMWDwIk3nH/1W4h76RIpMLOsQygYhUInnsNtFwh4wbaMBkcDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: NKqx9R4/H15HpRU5WhiwSGy4XZ/7p2Lrm5ohptMWDwIk3nH/1W4h76RIpMLOsQygYhUInnsNtFwh4wbaMBkcDg== {"files":[{"bytes":19062,"name":"index.html","sha256":"9f56e07a47ed47224c5845ec4669baf977a38a69bf4abf060d98df9eb6b33e17"},{"bytes":8560,"name":"publication.md","sha256":"48decb9713c027f5e7fed0f7e5d852dde693bef224441cdd0b808c2e64fd37cb"},{"bytes":8214,"name":"publication.txt","sha256":"c5b2c5e408f4c532fa8c6d026f48a0fdc6506cb8682801786878d412697ae068"},{"bytes":2873,"name":"manifest.json","sha256":"089f06d04b0abd09d2742b7596406225f94426831c85e633c134f79f8fae6455"},{"bytes":89,"name":"manifest.sig","sha256":"a8d71e32653e398fbcb104359ab57b52d8b2470c7ebf523ea72421f27098cfe8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8066549e4be0b2c9901390ff1d23b79e335cd31f78fde182d5a8b92ea9453dcf"}],"publication_id":"OT-2026-000089107"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089107
OpenTechnical

OT-2026-000089107

Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c5b2c5e408f4c532fa8c6d026f48a0fdc6506cb8682801786878d412697ae068

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089107, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089107.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089107" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089107" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089107 Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089107 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089107 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089107 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089107", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19062, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9f56e07a47ed47224c5845ec4669baf977a38a69bf4abf060d98df9eb6b33e17" }, { "bytes": 8560, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "48decb9713c027f5e7fed0f7e5d852dde693bef224441cdd0b808c2e64fd37cb" }, { "bytes": 8214, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c5b2c5e408f4c532fa8c6d026f48a0fdc6506cb8682801786878d412697ae068" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089107/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089107", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-79c1-ad94-bb011505680c" } XCPd96tC80zLupPH1ZOwDAW5ITZWVN2zzQqQkRAyFtFqOQn83bgHXUF/KlAHRJE6RJp3O8qP1bBM7vgaoHBNBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: XCPd96tC80zLupPH1ZOwDAW5ITZWVN2zzQqQkRAyFtFqOQn83bgHXUF/KlAHRJE6RJp3O8qP1bBM7vgaoHBNBA== {"files":[{"bytes":18504,"name":"index.html","sha256":"0e34c6469ded5c90d44282ce6cdab708bda91da8b665e34bc3750306edc93aff"},{"bytes":8073,"name":"publication.md","sha256":"5f7f90cedb8dec7b396d4ab844d4645210a49ad58dee145b1a13a529424335ea"},{"bytes":7733,"name":"publication.txt","sha256":"f3b2fbcf8b4d803633d2cbc0c6593a8ac115a005a329124470fc4696df3a6983"},{"bytes":2861,"name":"manifest.json","sha256":"0c9a7f21ffc9920655b4bec8e779c2268d227083a19527326f97721bab73b142"},{"bytes":89,"name":"manifest.sig","sha256":"bb70cf0863e2a40fae5ca826de6db328224f3a0a8b99f0b0866c60a9ef00fcb0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"26897aed10234c84c649c552833a2c11ccda5e041cfb22a4d1c23010c17b082e"}],"publication_id":"OT-2026-000089108"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089108
OpenTechnical

OT-2026-000089108

Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
f3b2fbcf8b4d803633d2cbc0c6593a8ac115a005a329124470fc4696df3a6983

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089108, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089108.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089108" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089108" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089108 Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089108 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089108 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089108 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089108", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18504, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0e34c6469ded5c90d44282ce6cdab708bda91da8b665e34bc3750306edc93aff" }, { "bytes": 8073, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5f7f90cedb8dec7b396d4ab844d4645210a49ad58dee145b1a13a529424335ea" }, { "bytes": 7733, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f3b2fbcf8b4d803633d2cbc0c6593a8ac115a005a329124470fc4696df3a6983" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089108/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089108", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-77d2-a1b0-017a041c601d" } 0+gHAYW/pCzoVZX0v+6XXB+xAWspeP+6kfOa5xztkRU9vfk7bF2xgclyopx2eatJtayWu2yOY4O6/UZu785yCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 0+gHAYW/pCzoVZX0v+6XXB+xAWspeP+6kfOa5xztkRU9vfk7bF2xgclyopx2eatJtayWu2yOY4O6/UZu785yCQ== {"files":[{"bytes":19319,"name":"index.html","sha256":"5e01b80286dd4f248eb210e52fb75c302b132996d10e74547569f0bb239ce4d3"},{"bytes":8774,"name":"publication.md","sha256":"8102f4ef67ec495944c3195e65de1e9b791e529a611591237ccb751307496a32"},{"bytes":8428,"name":"publication.txt","sha256":"c643411f379b7638e023d19b9f5a982cd1bfeb811e676ed4a1744eb28d2737f3"},{"bytes":2873,"name":"manifest.json","sha256":"3ce9991ac6c99125109b2e3541a5af27e70451d1481a377746371490c4512432"},{"bytes":89,"name":"manifest.sig","sha256":"6e51131ae287b31860a4e76722a045efce3ec80266a4843072c5c6eb9c7ef28a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"413fc43bbf26b593d3885f8cd193f2813ba458aab0bfd26511a5686ae2eb19e9"}],"publication_id":"OT-2026-000089109"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089109
OpenTechnical

OT-2026-000089109

Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c643411f379b7638e023d19b9f5a982cd1bfeb811e676ed4a1744eb28d2737f3

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089109, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089109.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089109" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089109" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089109 Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089109 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089109 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089109 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089109", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19319, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5e01b80286dd4f248eb210e52fb75c302b132996d10e74547569f0bb239ce4d3" }, { "bytes": 8774, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8102f4ef67ec495944c3195e65de1e9b791e529a611591237ccb751307496a32" }, { "bytes": 8428, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c643411f379b7638e023d19b9f5a982cd1bfeb811e676ed4a1744eb28d2737f3" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089109/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089109", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7480-b184-f181fbeb723e" } N9D2ZuG5AnwX+IjL56VXObz1yT0KTsNbGEtcxreSc2u1SDEWUhKvi/H9LOQPkNhdJhZCalBlUT5DT/FTt1QHDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: N9D2ZuG5AnwX+IjL56VXObz1yT0KTsNbGEtcxreSc2u1SDEWUhKvi/H9LOQPkNhdJhZCalBlUT5DT/FTt1QHDw== {"files":[{"bytes":19066,"name":"index.html","sha256":"c9cece73abe97854dfef15edd031c9929e1c3bf39afe815e7d075ce982284e83"},{"bytes":8564,"name":"publication.md","sha256":"cd0e1202c4cc4a0334c13c56ddb85f48412e80b71e898fe9cea00210613eb59a"},{"bytes":8218,"name":"publication.txt","sha256":"b47eac3943477aede73af8cf6e7b241e6de585811e52b0ec8a848a026404a4ed"},{"bytes":2873,"name":"manifest.json","sha256":"59a54e5487a2cc704b378327e25440628253b24fe5afbb40833ee10a1e7ad556"},{"bytes":89,"name":"manifest.sig","sha256":"f0784dcb0d030daf5c7c18c66645aac0e42cbf0eedacbc57989a03e26e610ee7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4ded5a6522ca11b0cc8df7f60aa051fa80e2c734726a253f9e024d38cef15a34"}],"publication_id":"OT-2026-000089110"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089110
OpenTechnical

OT-2026-000089110

Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
b47eac3943477aede73af8cf6e7b241e6de585811e52b0ec8a848a026404a4ed

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089110, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089110.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089110" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089110" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089110 Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089110 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089110 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089110 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089110", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19066, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c9cece73abe97854dfef15edd031c9929e1c3bf39afe815e7d075ce982284e83" }, { "bytes": 8564, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cd0e1202c4cc4a0334c13c56ddb85f48412e80b71e898fe9cea00210613eb59a" }, { "bytes": 8218, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b47eac3943477aede73af8cf6e7b241e6de585811e52b0ec8a848a026404a4ed" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089110/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089110", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7fbf-ba07-73691c37d66d" } t/PXIebxd2JcYgUpOAUDuSPsx+8runRCMG/vrjTt8G70Lxqylc71elUbSd6oA3dgG/+sOTir30YedZPc6/DhCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: t/PXIebxd2JcYgUpOAUDuSPsx+8runRCMG/vrjTt8G70Lxqylc71elUbSd6oA3dgG/+sOTir30YedZPc6/DhCg== {"files":[{"bytes":18677,"name":"index.html","sha256":"f7a85870008c62b2f151d47ee9a027a5cfd383a44723b2fd5bc327c0c4f1a64f"},{"bytes":8218,"name":"publication.md","sha256":"76bd4882ff83bbd04b2d353489fe9a8e3b18f4e6832418f04d35b8855b1cf6c1"},{"bytes":7890,"name":"publication.txt","sha256":"4b1c4651e869566282c32474bc3cdfccf89f7035a9bd60e14f485cd428d4263a"},{"bytes":2836,"name":"manifest.json","sha256":"d6b47937029a783b22c7cc952d4a5e3390157506aec667e90c4f3f72f7e6bd30"},{"bytes":89,"name":"manifest.sig","sha256":"8b26d13e5a7f31265cfb0a6106b45f1aae5347840d5aebfc1341a05572e6aedb"},{"bytes":227,"name":"manifest.sig.txt","sha256":"117dc4044dba24d8e677673160c58289585100352aceb74029658fd0b3e884c1"}],"publication_id":"OT-2026-000089111"} Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089111
OpenTechnical

OT-2026-000089111

Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
4b1c4651e869566282c32474bc3cdfccf89f7035a9bd60e14f485cd428d4263a

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089111, “Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089111.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089111" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089111" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089111 Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089111 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089111 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089111 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089111", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1151 }, "figures": [], "files": [ { "bytes": 18677, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f7a85870008c62b2f151d47ee9a027a5cfd383a44723b2fd5bc327c0c4f1a64f" }, { "bytes": 8218, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "76bd4882ff83bbd04b2d353489fe9a8e3b18f4e6832418f04d35b8855b1cf6c1" }, { "bytes": 7890, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4b1c4651e869566282c32474bc3cdfccf89f7035a9bd60e14f485cd428d4263a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089111/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089111", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-7246-9042-49714a8f804d" } m3yCHoqmL7L9COPGy/K/0wtRy0Cq5qhTfFXpav2+1fVxkzebD9SAA9v7TJeFuwhAJbIjXRKuDuGSX2a5N0J/Aw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: m3yCHoqmL7L9COPGy/K/0wtRy0Cq5qhTfFXpav2+1fVxkzebD9SAA9v7TJeFuwhAJbIjXRKuDuGSX2a5N0J/Aw== {"files":[{"bytes":19492,"name":"index.html","sha256":"f6641d21fb6c8cfb034237682aa417230d0488c15573afe3802d090763d2266a"},{"bytes":8919,"name":"publication.md","sha256":"ca7ee185797bcb5a1c2b4bf29623da0cd6ef2b10f4d814ab1520cfa025b657e9"},{"bytes":8585,"name":"publication.txt","sha256":"4080bea3a8932a6c1573fc7e421c838e80a329c89e6cb0680dc6463b062f4161"},{"bytes":2848,"name":"manifest.json","sha256":"e0e20d3da16b9339648aa07fd46cbdc806fd4e58de51bedc8bea6fe0bdd29f05"},{"bytes":89,"name":"manifest.sig","sha256":"dac3c0b31db2f8c29429fe6f13592353c2930686f208ad8f3091fb8ae33b07a4"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c6566775f3867156ecd0efad775a64b05e576972ae713389aaea52349e9449e5"}],"publication_id":"OT-2026-000089112"} Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089112
OpenTechnical

OT-2026-000089112

Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
4080bea3a8932a6c1573fc7e421c838e80a329c89e6cb0680dc6463b062f4161

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089112, “Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089112.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089112" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089112" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089112 Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089112 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089112 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089112 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089112", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1257 }, "figures": [], "files": [ { "bytes": 19492, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f6641d21fb6c8cfb034237682aa417230d0488c15573afe3802d090763d2266a" }, { "bytes": 8919, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ca7ee185797bcb5a1c2b4bf29623da0cd6ef2b10f4d814ab1520cfa025b657e9" }, { "bytes": 8585, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4080bea3a8932a6c1573fc7e421c838e80a329c89e6cb0680dc6463b062f4161" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089112/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089112", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7ebd-a9c0-3535afc5f91f" } dxYeMG3r7AIyF5r8RvVROzfxfcZO0+8gqmOoJv7boH9el7lsk4UsjwQaUuC6EgPlwXeg8RKWcV800lLv/eyPAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: dxYeMG3r7AIyF5r8RvVROzfxfcZO0+8gqmOoJv7boH9el7lsk4UsjwQaUuC6EgPlwXeg8RKWcV800lLv/eyPAA== {"files":[{"bytes":19239,"name":"index.html","sha256":"891015e79bfbcb609c50e5702536f097f88443e5505c096faddbce07c912b45f"},{"bytes":8709,"name":"publication.md","sha256":"19cafbe968ffb2d303b6a38d67d700fcd8da21c4833d4260c02439ceb86ea5d8"},{"bytes":8375,"name":"publication.txt","sha256":"ecee223946c2165b00b1609ef727a3a50279e99a404de0fc70f510bfb3351445"},{"bytes":2848,"name":"manifest.json","sha256":"64867a53fa3643a8a012f47379983f2488de12393fce007923d2a6d7a1240db5"},{"bytes":89,"name":"manifest.sig","sha256":"a7f023c35e83396974a448096f82128f0249fe7b232f029f7607ad6d64a9f0ca"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1ad188243cf7e48439c0ebd81ff120f9286d2d8b0e7776c1b978e7a9b503074c"}],"publication_id":"OT-2026-000089113"} Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089113
OpenTechnical

OT-2026-000089113

Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
ecee223946c2165b00b1609ef727a3a50279e99a404de0fc70f510bfb3351445

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089113, “Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089113.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089113" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089113" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089113 Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089113 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089113 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089113 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089113", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1222 }, "figures": [], "files": [ { "bytes": 19239, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "891015e79bfbcb609c50e5702536f097f88443e5505c096faddbce07c912b45f" }, { "bytes": 8709, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "19cafbe968ffb2d303b6a38d67d700fcd8da21c4833d4260c02439ceb86ea5d8" }, { "bytes": 8375, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ecee223946c2165b00b1609ef727a3a50279e99a404de0fc70f510bfb3351445" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089113/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089113", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-daff-7f96-8e4a-d8de934f575b" } nwakUzwnWRp5N0ec4yX4PvRVoSQOjXiixzDQiwXjyJE1X9WlFVxFp9/w6AVP4h48vt5YumFXh0nhIceCVTmvCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: nwakUzwnWRp5N0ec4yX4PvRVoSQOjXiixzDQiwXjyJE1X9WlFVxFp9/w6AVP4h48vt5YumFXh0nhIceCVTmvCg== {"files":[{"bytes":18623,"name":"index.html","sha256":"173bf84697f0dc7b8becb00cd514f15341c8c5aaf6846ac9b9dedf571d2a7145"},{"bytes":8164,"name":"publication.md","sha256":"c4ded1b0632c63e5b77a82f172a31ab2c32bbd27e31ca3fc008148473b00a95f"},{"bytes":7836,"name":"publication.txt","sha256":"74b8e2d73f757db3d03ddecf14f089ae590cb7282800176e2801bd1e83a46613"},{"bytes":2836,"name":"manifest.json","sha256":"6a55e64169d09fd31049e148f890787d7f8cf45f919b866f2bdbb1b4f0658b44"},{"bytes":89,"name":"manifest.sig","sha256":"448d061fb63a4a524c83970cc50b4a0f7169657976cd624de1550144f977d68f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3e69f0b0673c10e4f20289d68246a47b37029758c06e09b4f3d56c0b6911f003"}],"publication_id":"OT-2026-000089114"} Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089114
OpenTechnical

OT-2026-000089114

Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
74b8e2d73f757db3d03ddecf14f089ae590cb7282800176e2801bd1e83a46613

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089114, “Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089114.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089114" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089114" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089114 Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089114 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089114 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089114 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089114", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1136 }, "figures": [], "files": [ { "bytes": 18623, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "173bf84697f0dc7b8becb00cd514f15341c8c5aaf6846ac9b9dedf571d2a7145" }, { "bytes": 8164, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c4ded1b0632c63e5b77a82f172a31ab2c32bbd27e31ca3fc008148473b00a95f" }, { "bytes": 7836, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "74b8e2d73f757db3d03ddecf14f089ae590cb7282800176e2801bd1e83a46613" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089114/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089114", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-daff-76fd-a897-fda6303ae164" } T5wpXbxjwDUzgwq5amrVOzgHVMNYaicoAv3phxoKE1sxefvmtlzZsaXIGJhAz6N9VMMgjF/xGu3yLgqYhG3NBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: T5wpXbxjwDUzgwq5amrVOzgHVMNYaicoAv3phxoKE1sxefvmtlzZsaXIGJhAz6N9VMMgjF/xGu3yLgqYhG3NBQ== {"files":[{"bytes":19438,"name":"index.html","sha256":"73f43e9ee96a049e5f094c8a8e1de241c1f209b174bf80883db435191837482f"},{"bytes":8865,"name":"publication.md","sha256":"57108935fb71e8dd45748e493d289c1434b6b1c31cc81dd282364f30f77dd580"},{"bytes":8531,"name":"publication.txt","sha256":"cc0c60f8a578e3c36ddef6addca4bede080156ee1bebbed707b5735025f65a54"},{"bytes":2848,"name":"manifest.json","sha256":"3d27e98ffef63be665ba3f530a3ee36212f16ed1e33b6a557453cd39706392db"},{"bytes":89,"name":"manifest.sig","sha256":"a98a42b27fec7b1121897fea605913117d322e140434ce7cd6971214851f3648"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b88755a954f0075babcf230f1617a5d400ddd88bd2558abe70e9935b6d5b7c98"}],"publication_id":"OT-2026-000089115"} Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089115
OpenTechnical

OT-2026-000089115

Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cc0c60f8a578e3c36ddef6addca4bede080156ee1bebbed707b5735025f65a54

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089115, “Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089115.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089115" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089115" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089115 Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089115 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089115 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089115 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089115", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1242 }, "figures": [], "files": [ { "bytes": 19438, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "73f43e9ee96a049e5f094c8a8e1de241c1f209b174bf80883db435191837482f" }, { "bytes": 8865, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "57108935fb71e8dd45748e493d289c1434b6b1c31cc81dd282364f30f77dd580" }, { "bytes": 8531, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cc0c60f8a578e3c36ddef6addca4bede080156ee1bebbed707b5735025f65a54" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089115/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089115", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7955-809d-915d50dce339" } O5HFLVJRkB7yg1Hb8LEyASBCBnwEBLlVW1pCVQXdXHS0+lkw/VMJmQH/BX8cUKzEp5I9OOSBpMla9pPiZGKwAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: O5HFLVJRkB7yg1Hb8LEyASBCBnwEBLlVW1pCVQXdXHS0+lkw/VMJmQH/BX8cUKzEp5I9OOSBpMla9pPiZGKwAg== {"files":[{"bytes":19185,"name":"index.html","sha256":"bc0a81871a8e196ffaa196b0b35c5847052ae0766da0846ddebf2a1803b9f4fe"},{"bytes":8655,"name":"publication.md","sha256":"f36446af76ad30328aac2530bb9c86df09dfc9df3d387c34f793c0e787447721"},{"bytes":8321,"name":"publication.txt","sha256":"7a23121f8ea9cbcb9f009f31cffd01f3f42e7ba21f4d3c2a6f1cb852a042e9d2"},{"bytes":2848,"name":"manifest.json","sha256":"52de32384e1a797b2d7569940d2c04dada698c1469c68c06564ce3380b0e6895"},{"bytes":89,"name":"manifest.sig","sha256":"868f26a6e17cebdf40aa28b426db96ac62cc1a6a593a135b367bdb864d5033ad"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ae1e060b8f2c82eee574ed1515e95da67107052ca770b59e6d5b151f11df9a20"}],"publication_id":"OT-2026-000089116"} Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089116
OpenTechnical

OT-2026-000089116

Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7a23121f8ea9cbcb9f009f31cffd01f3f42e7ba21f4d3c2a6f1cb852a042e9d2

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089116, “Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089116.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089116" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089116" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089116 Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089116 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089116 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089116 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089116", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1207 }, "figures": [], "files": [ { "bytes": 19185, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bc0a81871a8e196ffaa196b0b35c5847052ae0766da0846ddebf2a1803b9f4fe" }, { "bytes": 8655, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f36446af76ad30328aac2530bb9c86df09dfc9df3d387c34f793c0e787447721" }, { "bytes": 8321, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7a23121f8ea9cbcb9f009f31cffd01f3f42e7ba21f4d3c2a6f1cb852a042e9d2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089116/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089116", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-768d-8ef6-64f5d43f963b" } TZ1FkgGpF9DTMkIMLjy15exnq/e0szokQFcR7iSJTns4hv06EA7T8R/yle3UK8dD9Rhvntx/r0lG4NHomOmnAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: TZ1FkgGpF9DTMkIMLjy15exnq/e0szokQFcR7iSJTns4hv06EA7T8R/yle3UK8dD9Rhvntx/r0lG4NHomOmnAg== {"files":[{"bytes":18393,"name":"index.html","sha256":"1502ddca9e94e6d7d9041b2e001fef9f801f5168473c5625c52b8fad08b372c9"},{"bytes":7978,"name":"publication.md","sha256":"5e516bfd3db1e1b01d8aa414ce579906aded8869b4a6f7c8e7e7bf87f1c5faa1"},{"bytes":7646,"name":"publication.txt","sha256":"c40ee00201506dbb0ef3f6784fd2261dedf950d6efc7f93a88e2270f30da1338"},{"bytes":2853,"name":"manifest.json","sha256":"3c8ea3cdd6d5bb5114f469c44f09e161c574d5755ccaa96e59bd7580a264ae3f"},{"bytes":89,"name":"manifest.sig","sha256":"09bce1541542b2f55506687d71fd501ac07c91ea9370cb9d84f7e4cd11be3320"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d4178e2db95602afdbb666b9c650a6365c39f5f41236b576a3fae690c0c58929"}],"publication_id":"OT-2026-000089117"} Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089117
OpenTechnical

OT-2026-000089117

Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
c40ee00201506dbb0ef3f6784fd2261dedf950d6efc7f93a88e2270f30da1338

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089117, “Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089117.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089117" title: "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089117" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089117 Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089117 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089117 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089117 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089117", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18393, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1502ddca9e94e6d7d9041b2e001fef9f801f5168473c5625c52b8fad08b372c9" }, { "bytes": 7978, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5e516bfd3db1e1b01d8aa414ce579906aded8869b4a6f7c8e7e7bf87f1c5faa1" }, { "bytes": 7646, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c40ee00201506dbb0ef3f6784fd2261dedf950d6efc7f93a88e2270f30da1338" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089117/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089117", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-72dd-8896-378fa39942bb" } 0Q15Y4PlSewdoTEThSJskwiIKPjaTrEx3t1m6eX3/7K9J5lSrECNRpRxb5PFk8NGwirSTe9Sx5NHH7xhySzsAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 0Q15Y4PlSewdoTEThSJskwiIKPjaTrEx3t1m6eX3/7K9J5lSrECNRpRxb5PFk8NGwirSTe9Sx5NHH7xhySzsAg== {"files":[{"bytes":19208,"name":"index.html","sha256":"68b68db22e7761430dd4fb51054dafa23102dadb3cb38a5a352fae8ba326ed03"},{"bytes":8679,"name":"publication.md","sha256":"d8e98c1e247e41d78db824a88db858c07706be94c3cdd404933ab1bc49ec7367"},{"bytes":8341,"name":"publication.txt","sha256":"724fd85f5ae553cca61df1e866c9ad84db6342f64a50fa3d5fdc96e2c88d20aa"},{"bytes":2865,"name":"manifest.json","sha256":"05b1708b961e71e21f18d2fafe5dda55b64c583ea150e2c7833a57f412f68b0d"},{"bytes":89,"name":"manifest.sig","sha256":"4899d49c95cfee7333a21abeb9db4992825385cca5bc0de187099f30a6882639"},{"bytes":227,"name":"manifest.sig.txt","sha256":"87e608f58361c7693f2366e3187b964351309595bffb56af3093eb761f3d4723"}],"publication_id":"OT-2026-000089118"} Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089118
OpenTechnical

OT-2026-000089118

Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
724fd85f5ae553cca61df1e866c9ad84db6342f64a50fa3d5fdc96e2c88d20aa

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089118, “Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089118.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089118" title: "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089118" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089118 Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089118 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089118 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089118 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089118", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19208, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "68b68db22e7761430dd4fb51054dafa23102dadb3cb38a5a352fae8ba326ed03" }, { "bytes": 8679, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d8e98c1e247e41d78db824a88db858c07706be94c3cdd404933ab1bc49ec7367" }, { "bytes": 8341, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "724fd85f5ae553cca61df1e866c9ad84db6342f64a50fa3d5fdc96e2c88d20aa" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089118/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089118", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7c39-99d2-b52be80e27b8" } 0pEbmxWQN34zU/LhqQy8nmNWPYjcgTfFsYhFafVRRiQzJfMwV9QL66dXx5PP/2oeoRi+AhLquS0Knpw8lQCxDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 0pEbmxWQN34zU/LhqQy8nmNWPYjcgTfFsYhFafVRRiQzJfMwV9QL66dXx5PP/2oeoRi+AhLquS0Knpw8lQCxDg== {"files":[{"bytes":18955,"name":"index.html","sha256":"8cb37abb240afe355033e80e2f48c3e6f0086138318c7d6fcfc2563a13432ed4"},{"bytes":8469,"name":"publication.md","sha256":"c9fc41eca670363ce4f4e010b03f382a2e147901413ce9c0428509a11ab8d310"},{"bytes":8131,"name":"publication.txt","sha256":"2ded285de9cab20aa644896ad6311f64edb90386eb83599ffe94972b39c584d2"},{"bytes":2865,"name":"manifest.json","sha256":"d98c5427e7717b83a692bd69cdbd3f6b6818f253a5632a4044f7cf8a557801f0"},{"bytes":89,"name":"manifest.sig","sha256":"5e887bf30c2c576c6049f6c6bc3fa57dd585ca0159204b5bba11d5ed05ec052a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7bc4939309b75492a05df7e49ac82861d1fafdfc3e887bea311f79fbcd4df64b"}],"publication_id":"OT-2026-000089119"} Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089119
OpenTechnical

OT-2026-000089119

Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
2ded285de9cab20aa644896ad6311f64edb90386eb83599ffe94972b39c584d2

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089119, “Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089119.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089119" title: "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089119" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089119 Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089119 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089119 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089119 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089119", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18955, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8cb37abb240afe355033e80e2f48c3e6f0086138318c7d6fcfc2563a13432ed4" }, { "bytes": 8469, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c9fc41eca670363ce4f4e010b03f382a2e147901413ce9c0428509a11ab8d310" }, { "bytes": 8131, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2ded285de9cab20aa644896ad6311f64edb90386eb83599ffe94972b39c584d2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089119/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089119", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7242-b3d6-439169054fb6" } zF5lX2uq0GrQP+pYNZ+nbmf65bSNoZMn5UShixTfBwrEKo560DcHxY95S5lgYzhVRgSnoSfAtm5eZrHTKXUzBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: zF5lX2uq0GrQP+pYNZ+nbmf65bSNoZMn5UShixTfBwrEKo560DcHxY95S5lgYzhVRgSnoSfAtm5eZrHTKXUzBw== {"files":[{"bytes":18393,"name":"index.html","sha256":"3bdef4b71080d572ddcd01618a259c761a379c8d0549af1542de1b41835b0509"},{"bytes":7978,"name":"publication.md","sha256":"48680ef5e2d21f21a0a7c518080ac1510122884bfd6dda1088d7c41774c455fc"},{"bytes":7646,"name":"publication.txt","sha256":"9a6cb206bba06e59a5b92b4a186cf2bb2eddd89f6c3b9038fdb258816f7c74a6"},{"bytes":2853,"name":"manifest.json","sha256":"7c24b9f5c6d2c749b3d867ab172a06119e0516553481fbfecca0383875fbc990"},{"bytes":89,"name":"manifest.sig","sha256":"66c981bd3744a58e8f5bc5088997b50d083e905633f3ca88f0182c134c2bf915"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f7724360fab3c80bfa33fb7c93569db96c0f5283bc975c66e9e7367d982c14da"}],"publication_id":"OT-2026-000089120"} Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089120
OpenTechnical

OT-2026-000089120

Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
9a6cb206bba06e59a5b92b4a186cf2bb2eddd89f6c3b9038fdb258816f7c74a6

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089120, “Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089120.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089120" title: "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089120" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089120 Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089120 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089120 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089120 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089120", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18393, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3bdef4b71080d572ddcd01618a259c761a379c8d0549af1542de1b41835b0509" }, { "bytes": 7978, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "48680ef5e2d21f21a0a7c518080ac1510122884bfd6dda1088d7c41774c455fc" }, { "bytes": 7646, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9a6cb206bba06e59a5b92b4a186cf2bb2eddd89f6c3b9038fdb258816f7c74a6" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089120/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089120", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7a7a-9bf4-5b861c32dec1" } gZuYfPA0DWHyUzgqcETKf+lmsunaItJPC13zfPKLlp64Ni9QnA7k8H/1r2Nh++jZavk16aKrNX/r3TcY3WTSDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: gZuYfPA0DWHyUzgqcETKf+lmsunaItJPC13zfPKLlp64Ni9QnA7k8H/1r2Nh++jZavk16aKrNX/r3TcY3WTSDQ== {"files":[{"bytes":19208,"name":"index.html","sha256":"f0bce09d603412074a4795698bccd74f95f70504c740d66aae16364b7afea5d9"},{"bytes":8679,"name":"publication.md","sha256":"7e74a782e8af68ad5d1d7d6c07b48c70092450f40540a6fdb7259a9dde47bac1"},{"bytes":8341,"name":"publication.txt","sha256":"06002e5aaff2e3a540602e4a564dc0746d0ee19a3abfb5c31329473db4bdd364"},{"bytes":2865,"name":"manifest.json","sha256":"4884b6d658528d88074a5ad44995cb86b31c6e748b0b01b8c069b53234d3c4b8"},{"bytes":89,"name":"manifest.sig","sha256":"a6abc756d37dd838460add031bbc2dbcb9c27c4bbd85bf7678ea9f7f14045e0c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ebc6b1d61026a3f37fe1d5a90d6c28ef15e77ae664c287a272483ce9199c3c60"}],"publication_id":"OT-2026-000089121"} Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089121
OpenTechnical

OT-2026-000089121

Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
06002e5aaff2e3a540602e4a564dc0746d0ee19a3abfb5c31329473db4bdd364

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089121, “Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089121.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089121" title: "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089121" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089121 Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089121 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089121 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089121 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089121", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19208, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f0bce09d603412074a4795698bccd74f95f70504c740d66aae16364b7afea5d9" }, { "bytes": 8679, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7e74a782e8af68ad5d1d7d6c07b48c70092450f40540a6fdb7259a9dde47bac1" }, { "bytes": 8341, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "06002e5aaff2e3a540602e4a564dc0746d0ee19a3abfb5c31329473db4bdd364" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089121/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089121", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7980-8c7b-9dd4d59ec145" } M96ACILP38TlN8JVi6k7RbucXXjd956ex8oxXK630kpPLrbT00gY/VS9qhKBuuc3XBagUBzSPVGFePxlf9M0BA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: M96ACILP38TlN8JVi6k7RbucXXjd956ex8oxXK630kpPLrbT00gY/VS9qhKBuuc3XBagUBzSPVGFePxlf9M0BA== {"files":[{"bytes":18955,"name":"index.html","sha256":"bb6331d9acd77310da720335d91edf0bb243ca19ef4f6d3079efdac4c800a424"},{"bytes":8469,"name":"publication.md","sha256":"f5f151c6aaf9f2b83ced8e14d69ca66242a2e9caf502e6a201965ca6fd00f288"},{"bytes":8131,"name":"publication.txt","sha256":"a693f7ba5582a1a41f9fc6926e29cdec36b05dfd520b6471b69a24fa4d8fb947"},{"bytes":2865,"name":"manifest.json","sha256":"e9ad686e43e1573a1a5c566813e145f8a48d69a0c041ef0b6ce4a11f3490aa0d"},{"bytes":89,"name":"manifest.sig","sha256":"a8b73afa17cb790eacd7286c9cf289e8f5a482be79b33962e72eb3a1ea9c93c0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b13c2e40e1700e794456a8249b4a120f9a4315bed000080ac50af6db8890d625"}],"publication_id":"OT-2026-000089122"} Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089122
OpenTechnical

OT-2026-000089122

Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a693f7ba5582a1a41f9fc6926e29cdec36b05dfd520b6471b69a24fa4d8fb947

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089122, “Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089122.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089122" title: "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089122" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089122 Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089122 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089122 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089122 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089122", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18955, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bb6331d9acd77310da720335d91edf0bb243ca19ef4f6d3079efdac4c800a424" }, { "bytes": 8469, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f5f151c6aaf9f2b83ced8e14d69ca66242a2e9caf502e6a201965ca6fd00f288" }, { "bytes": 8131, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a693f7ba5582a1a41f9fc6926e29cdec36b05dfd520b6471b69a24fa4d8fb947" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089122/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089122", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-71fb-bf07-48e89dda3f0b" } +lFqa0aZ7QU5XoklX/yCkD3hTSjVfCz2xtXCNS+VgZEGRZdtvwR1bJRtMvzAzDVwaJQJwhmA77kiK4gl4y9cBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: +lFqa0aZ7QU5XoklX/yCkD3hTSjVfCz2xtXCNS+VgZEGRZdtvwR1bJRtMvzAzDVwaJQJwhmA77kiK4gl4y9cBw== {"files":[{"bytes":18511,"name":"index.html","sha256":"c2f3ec08f4fd1b2e0197996262916aa24f1ee342ad97bf535b19f679f15dd1bf"},{"bytes":8076,"name":"publication.md","sha256":"33eba4b60fbc5ba587c1ada2635512b6faf342bc808c4c32dcd3e43c7ef78c84"},{"bytes":7734,"name":"publication.txt","sha256":"1165d4f5859db616e198c6f59fbb4369c01f2b180da4ef0f72306f5a629a8626"},{"bytes":2863,"name":"manifest.json","sha256":"c7ac4db2da6b8fcdcb428700b29ca14a1be1cdc3f08bf0b00e01e66e191c9bec"},{"bytes":89,"name":"manifest.sig","sha256":"a6fc6541eb03eff6a79bc5fd5ea3c39fb327eacb9451016d7ee44ed9f755beed"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4943777cb6ea184b9f0e986459b205157c1f372c75a7be1f8026c0ca603213bf"}],"publication_id":"OT-2026-000089123"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089123
OpenTechnical

OT-2026-000089123

Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
1165d4f5859db616e198c6f59fbb4369c01f2b180da4ef0f72306f5a629a8626

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089123, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089123.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089123" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089123" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089123 Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089123 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089123 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089123 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089123", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18511, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c2f3ec08f4fd1b2e0197996262916aa24f1ee342ad97bf535b19f679f15dd1bf" }, { "bytes": 8076, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "33eba4b60fbc5ba587c1ada2635512b6faf342bc808c4c32dcd3e43c7ef78c84" }, { "bytes": 7734, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1165d4f5859db616e198c6f59fbb4369c01f2b180da4ef0f72306f5a629a8626" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089123/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089123", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-705e-a2e5-870220da67b7" } U1J/C7VrKLZxrwDr1jdMk67C45i/cHLDH+CNQSR2mjf+jhAQ/qrWSxAtaV3t/xKCFoVP4VLA/TrRIzl9iupfDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: U1J/C7VrKLZxrwDr1jdMk67C45i/cHLDH+CNQSR2mjf+jhAQ/qrWSxAtaV3t/xKCFoVP4VLA/TrRIzl9iupfDA== {"files":[{"bytes":19326,"name":"index.html","sha256":"bb6f476f1d7d5e9d5c03e51383a8f66ca518de4c32e01bea2b69cb96143580ce"},{"bytes":8777,"name":"publication.md","sha256":"4bac2a8353b42228f4ccc457f654f8b1046a112f2631e74f5be7926a57712706"},{"bytes":8429,"name":"publication.txt","sha256":"8c024132b98170e74018ec8baa42d1718fe52cc0b29abe797964207aeda41e67"},{"bytes":2875,"name":"manifest.json","sha256":"03cd0b430a633f52884fd683e46005b821ef453e620495badf4b82c6f2184d25"},{"bytes":89,"name":"manifest.sig","sha256":"b2d211b943171fd2fdc68d20a5a053780e37331f41082b483788467b5a77d5f7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0bc714d9784302336b7169768c931d60b63abe3d04cba3829e95f0c92dc154d8"}],"publication_id":"OT-2026-000089124"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089124
OpenTechnical

OT-2026-000089124

Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8c024132b98170e74018ec8baa42d1718fe52cc0b29abe797964207aeda41e67

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089124, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089124.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089124" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089124" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089124 Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089124 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089124 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089124 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089124", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19326, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bb6f476f1d7d5e9d5c03e51383a8f66ca518de4c32e01bea2b69cb96143580ce" }, { "bytes": 8777, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4bac2a8353b42228f4ccc457f654f8b1046a112f2631e74f5be7926a57712706" }, { "bytes": 8429, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8c024132b98170e74018ec8baa42d1718fe52cc0b29abe797964207aeda41e67" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089124/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089124", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7331-b51e-c20fd31f4c88" } 2MERoj4QCSyXdJDkYv8Q5ADUaOwvvxJ5oXZ9cF68qSxvorM0seaM/qZaMtTZ9PJly1lnxgb5d1Idxtwn22AvBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 2MERoj4QCSyXdJDkYv8Q5ADUaOwvvxJ5oXZ9cF68qSxvorM0seaM/qZaMtTZ9PJly1lnxgb5d1Idxtwn22AvBQ== {"files":[{"bytes":19073,"name":"index.html","sha256":"b9814715974c23f81476d995fff03d0e75c0d741ae3bc80656ae812eefc433db"},{"bytes":8567,"name":"publication.md","sha256":"5de41574228dfe7e7fcfc84b1db1ab5bfe2b4cec3c1dc31a6f9c8e410eeb0b30"},{"bytes":8219,"name":"publication.txt","sha256":"061f19b5566f6e893a0e4028ff2bbad7d4f0448e68921dcefa7fccdb498fc92b"},{"bytes":2875,"name":"manifest.json","sha256":"f8d548b85e820b080b67225c674a01d9ce1a10527bdc46f0d15f1ef153e09e75"},{"bytes":89,"name":"manifest.sig","sha256":"e75034aff8ce121eb69968545304d393044f84d4055b614dc4fab8e1c5b05431"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f7fc29cc9704036cb0a03693d56a2291ffa0f918eda39d0866838fe45b31702f"}],"publication_id":"OT-2026-000089125"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089125
OpenTechnical

OT-2026-000089125

Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
061f19b5566f6e893a0e4028ff2bbad7d4f0448e68921dcefa7fccdb498fc92b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089125, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089125.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089125" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089125" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089125 Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089125 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089125 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089125 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089125", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19073, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b9814715974c23f81476d995fff03d0e75c0d741ae3bc80656ae812eefc433db" }, { "bytes": 8567, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5de41574228dfe7e7fcfc84b1db1ab5bfe2b4cec3c1dc31a6f9c8e410eeb0b30" }, { "bytes": 8219, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "061f19b5566f6e893a0e4028ff2bbad7d4f0448e68921dcefa7fccdb498fc92b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089125/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089125", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-74ec-8c74-ce16bec7cb3e" } FNxeweXCQ3jQRk1LEALEbUl8Lt3xHMo4f+vmndEKUSU9KW9CizS60V9B3UuXNFuQpbR4eIeD6sTOQTWdvTGdBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: FNxeweXCQ3jQRk1LEALEbUl8Lt3xHMo4f+vmndEKUSU9KW9CizS60V9B3UuXNFuQpbR4eIeD6sTOQTWdvTGdBA== {"files":[{"bytes":18512,"name":"index.html","sha256":"5a2a0d972909bd555bd888db239f2c1a3a77aef0fb75ebbf61f2541811355ca8"},{"bytes":8077,"name":"publication.md","sha256":"b4030e6e65e1bb1d27687791ff5fd1ba3aa88606616b6f0ce5c9e220707da5d2"},{"bytes":7735,"name":"publication.txt","sha256":"4c4e83988d0a3e504836f509a28ca1d50783d70d9cbfc1c02baec062112525ab"},{"bytes":2863,"name":"manifest.json","sha256":"60ac10123fc2aaf66768ec6a4700d372258b7868e4dbe6bc25ab30fbbfe16d98"},{"bytes":89,"name":"manifest.sig","sha256":"68f6e00589af07d5d628d7b6484e589a8dd805e356e817bc9feffb1676d38d86"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7e70cfd35dffe1857181e2057007ac88af8e7b16ee41cca06f1e841e43cfef30"}],"publication_id":"OT-2026-000089126"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089126
OpenTechnical

OT-2026-000089126

Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
4c4e83988d0a3e504836f509a28ca1d50783d70d9cbfc1c02baec062112525ab

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089126, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089126.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089126" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089126" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089126 Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089126 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089126 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089126 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089126", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18512, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5a2a0d972909bd555bd888db239f2c1a3a77aef0fb75ebbf61f2541811355ca8" }, { "bytes": 8077, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b4030e6e65e1bb1d27687791ff5fd1ba3aa88606616b6f0ce5c9e220707da5d2" }, { "bytes": 7735, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4c4e83988d0a3e504836f509a28ca1d50783d70d9cbfc1c02baec062112525ab" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089126/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089126", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-740d-92f4-707c2ea44009" } YHF9tXifvkHFEDnbNMOUwat2h9sb4lo9dMp1EMSP/JMEXUBMg/pJSM2YIZtH30q0vocyPLkOBvzHF1/mRQdeAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: YHF9tXifvkHFEDnbNMOUwat2h9sb4lo9dMp1EMSP/JMEXUBMg/pJSM2YIZtH30q0vocyPLkOBvzHF1/mRQdeAg== {"files":[{"bytes":19327,"name":"index.html","sha256":"297140c20adb5c63ff729c33a20f1d02a29641cf5860f92a551912baed2387f1"},{"bytes":8778,"name":"publication.md","sha256":"3288ab348cf847a6f063486f7517d606fdf7299873c1288e7e856aef8d81b50a"},{"bytes":8430,"name":"publication.txt","sha256":"84b5a6defcf6548be65f9f9918f3a50485955012d15cdb482d7bca05ecb2804b"},{"bytes":2875,"name":"manifest.json","sha256":"f3c5cb4be5cac4bd617d7968faaf2003c64debb299537c5d4e6e0abd3fe86c13"},{"bytes":89,"name":"manifest.sig","sha256":"20bd9beb78b5d4410ee94eb319b0a526f5e88fe871beb67c65293a22f09938e0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"24435f757c6a4f9cc9d20fe64d699420cca5cfbe0d14d6f0333e186a196b3233"}],"publication_id":"OT-2026-000089127"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089127
OpenTechnical

OT-2026-000089127

Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
84b5a6defcf6548be65f9f9918f3a50485955012d15cdb482d7bca05ecb2804b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089127, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089127.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089127" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089127" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089127 Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089127 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089127 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089127 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089127", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19327, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "297140c20adb5c63ff729c33a20f1d02a29641cf5860f92a551912baed2387f1" }, { "bytes": 8778, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3288ab348cf847a6f063486f7517d606fdf7299873c1288e7e856aef8d81b50a" }, { "bytes": 8430, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "84b5a6defcf6548be65f9f9918f3a50485955012d15cdb482d7bca05ecb2804b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089127/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089127", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7935-8365-9d2f47bd6384" } gTJG43R11NatORe93ipt9mgzQOQemTRse5wCAAiSkjPOZH8GFTWIHF8ouCw9GNp/R24rFUQBA/p5Xa3+BFL7Cw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: gTJG43R11NatORe93ipt9mgzQOQemTRse5wCAAiSkjPOZH8GFTWIHF8ouCw9GNp/R24rFUQBA/p5Xa3+BFL7Cw== {"files":[{"bytes":19074,"name":"index.html","sha256":"912cb99866111c38ad363c538017908162f16d798d09b74b27c0a163c73c46e5"},{"bytes":8568,"name":"publication.md","sha256":"a39827aff4a3486f233f324dde50685c863f88200b1167df5a6520d5acbeb0ac"},{"bytes":8220,"name":"publication.txt","sha256":"3107288b35704aa7507c9077fca26fde9928552b6c9099742216fb0e83a446a0"},{"bytes":2875,"name":"manifest.json","sha256":"b6b75c9a1917c0c296117229d75fe013a6d8bf404bae800faaa6a41cc8b255ee"},{"bytes":89,"name":"manifest.sig","sha256":"2273d3a391db9487d7213ee1b3fa58e46aa26227aa67f2bcc6ec352c6df730c8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e78fb5b7d934b4facd586c457d55781a9d2521bbb3e9154e9355c4433c3c4b31"}],"publication_id":"OT-2026-000089128"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089128
OpenTechnical

OT-2026-000089128

Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
3107288b35704aa7507c9077fca26fde9928552b6c9099742216fb0e83a446a0

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089128, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089128.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089128" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089128" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089128 Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089128 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089128 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089128 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089128", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19074, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "912cb99866111c38ad363c538017908162f16d798d09b74b27c0a163c73c46e5" }, { "bytes": 8568, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a39827aff4a3486f233f324dde50685c863f88200b1167df5a6520d5acbeb0ac" }, { "bytes": 8220, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3107288b35704aa7507c9077fca26fde9928552b6c9099742216fb0e83a446a0" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089128/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089128", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-78ab-bc43-dbeb2f7f3fc5" } w/r5P2IIUo84eUf6zQ89nLLV+4C8ZaMSBak15oNscg4GifXOCfj6BubiDz31fLK5nCnCaEAqBdJJRReybTUAAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: w/r5P2IIUo84eUf6zQ89nLLV+4C8ZaMSBak15oNscg4GifXOCfj6BubiDz31fLK5nCnCaEAqBdJJRReybTUAAg== {"files":[{"bytes":18516,"name":"index.html","sha256":"12ac058b3c2d507555a30109df4c81c4b57fb519512484eb23408efcbfc0d6df"},{"bytes":8081,"name":"publication.md","sha256":"fcbb69bda43496e5329c40567019300646ee7270922b5289ccbe1f364df7d90d"},{"bytes":7739,"name":"publication.txt","sha256":"733e9622e7a5b5a1fe1a886dd18d9f08075f089a136e4888283345348f5e3a80"},{"bytes":2863,"name":"manifest.json","sha256":"49d265b56ada10a986d781fc056bed17656b00bef2bb43fe29e7fc699b28e55a"},{"bytes":89,"name":"manifest.sig","sha256":"6e26474e0f29239a034cb89322b4566aa6bb1f0faeedf8570c58120228c2ddbf"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0ea27191dbb3219d8e567006375bfa5c713cb0e67612e6eed2ce8b989336dbb6"}],"publication_id":"OT-2026-000089129"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089129
OpenTechnical

OT-2026-000089129

Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
733e9622e7a5b5a1fe1a886dd18d9f08075f089a136e4888283345348f5e3a80

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089129, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089129.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089129" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089129" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089129 Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089129 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089129 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089129 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089129", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18516, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "12ac058b3c2d507555a30109df4c81c4b57fb519512484eb23408efcbfc0d6df" }, { "bytes": 8081, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fcbb69bda43496e5329c40567019300646ee7270922b5289ccbe1f364df7d90d" }, { "bytes": 7739, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "733e9622e7a5b5a1fe1a886dd18d9f08075f089a136e4888283345348f5e3a80" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089129/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089129", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7dac-b89c-12d6a30446d6" } VI2haBo4MwPWtXqa+58GvQvEn57BN8CF+Wyp3Mwl+7N1H4eH8RFd2ixYkr9n87hrjSn9vBXOj/MmskQiwDs5Aw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: VI2haBo4MwPWtXqa+58GvQvEn57BN8CF+Wyp3Mwl+7N1H4eH8RFd2ixYkr9n87hrjSn9vBXOj/MmskQiwDs5Aw== {"files":[{"bytes":19331,"name":"index.html","sha256":"15e96df3c81a0e5d56a77353ee7e192e803267d7d850faa78e5da772391b45e8"},{"bytes":8782,"name":"publication.md","sha256":"5140f99d02195880a36a0068bc8d179671c945c634c7ee4bed01acbdc2b4726e"},{"bytes":8434,"name":"publication.txt","sha256":"e1ed2bc9667dbb9ccd23174352b933c878071faaf39c28453e76762ac5eabaef"},{"bytes":2875,"name":"manifest.json","sha256":"00829cfa3c5a7ccad0dd54b846c7b14fee5c5df3be3617f83def0088dd82b884"},{"bytes":89,"name":"manifest.sig","sha256":"862afc336e0fdb3e482b57599b77301a5708c6e77c826d6e146b75e6d3f7a265"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8f73e3d250a5ba8dfe9154129785b8d56e0e9f0c315e3246daa296dbb0814abe"}],"publication_id":"OT-2026-000089130"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089130
OpenTechnical

OT-2026-000089130

Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e1ed2bc9667dbb9ccd23174352b933c878071faaf39c28453e76762ac5eabaef

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089130, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089130.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089130" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089130" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089130 Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089130 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089130 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089130 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089130", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19331, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "15e96df3c81a0e5d56a77353ee7e192e803267d7d850faa78e5da772391b45e8" }, { "bytes": 8782, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5140f99d02195880a36a0068bc8d179671c945c634c7ee4bed01acbdc2b4726e" }, { "bytes": 8434, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e1ed2bc9667dbb9ccd23174352b933c878071faaf39c28453e76762ac5eabaef" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089130/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089130", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-741b-a487-975cf35867d4" } pwU7Bnufnrae4+CEBtLztJAsfndm3mhvxQeJ16GDAzg5xvn3DVTZy2rd+AfANzTKzp807F+M/KUJYJEWPSZqDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: pwU7Bnufnrae4+CEBtLztJAsfndm3mhvxQeJ16GDAzg5xvn3DVTZy2rd+AfANzTKzp807F+M/KUJYJEWPSZqDQ== {"files":[{"bytes":19078,"name":"index.html","sha256":"bfe9f260c6113a7d402d6228140ddc220b91169e496430069478475ac75e7a86"},{"bytes":8572,"name":"publication.md","sha256":"ca4495175cf162f110319b6e64b2ed3601d89f26f6df4b364abf02a3b7bde102"},{"bytes":8224,"name":"publication.txt","sha256":"af4475dc0e2f9aba5e163a5b1b02ca58d800313aeeb998ed2fa2cd7b332ddc61"},{"bytes":2875,"name":"manifest.json","sha256":"c0b70775f4e039031d4fd75e38b2f289a57d03342549c8b45f9a0e1d19f3371d"},{"bytes":89,"name":"manifest.sig","sha256":"d8d133597d4e429073c4f3572f31c98e503d8d9de47c638efc588ff65d3f0366"},{"bytes":227,"name":"manifest.sig.txt","sha256":"95238a7da80bfae71e4545b29fae9f72d44dda2773047d06b4d1649d294d7781"}],"publication_id":"OT-2026-000089131"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089131
OpenTechnical

OT-2026-000089131

Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
af4475dc0e2f9aba5e163a5b1b02ca58d800313aeeb998ed2fa2cd7b332ddc61

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089131, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089131.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089131" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089131" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089131 Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089131 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089131 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089131 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089131", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19078, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bfe9f260c6113a7d402d6228140ddc220b91169e496430069478475ac75e7a86" }, { "bytes": 8572, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ca4495175cf162f110319b6e64b2ed3601d89f26f6df4b364abf02a3b7bde102" }, { "bytes": 8224, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "af4475dc0e2f9aba5e163a5b1b02ca58d800313aeeb998ed2fa2cd7b332ddc61" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089131/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089131", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-732c-90a7-40b46d24ca34" } i+nwylH5f+FzY2vxFmCNFn9KVCI7Pm3vjdLsWkPZBEk/w3lKPfGWciRetKj98NwjYjLOz96ANS0oRF6UUPY8AA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: i+nwylH5f+FzY2vxFmCNFn9KVCI7Pm3vjdLsWkPZBEk/w3lKPfGWciRetKj98NwjYjLOz96ANS0oRF6UUPY8AA== {"files":[{"bytes":18689,"name":"index.html","sha256":"cd24ac63ef59fcb6116e400b277028c0ed9bf386b3bd987c3341466f3dc19344"},{"bytes":8226,"name":"publication.md","sha256":"66f64f7d2e7537eb077a2d9e5af2544a7c8b7dd858efa43a8bbe62c26668f23d"},{"bytes":7896,"name":"publication.txt","sha256":"3b85234d918a58ce57758b44c97adbc10008fc4f3095fef31cefdbd56c782ee7"},{"bytes":2838,"name":"manifest.json","sha256":"0bab4d3931b6e82f4a84969450566d6fdd71cde1984c68270adf0a6fec5e12cc"},{"bytes":89,"name":"manifest.sig","sha256":"a88969a8c2e139b9b65cab3930e0fbac5d61018dbfa4fba46d57a20900c50d28"},{"bytes":227,"name":"manifest.sig.txt","sha256":"bdec6e6a5e93f05be10f20eec4d9ddcc53cf9fb2daa4a5eae194578b460e9cd9"}],"publication_id":"OT-2026-000089132"} Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089132
OpenTechnical

OT-2026-000089132

Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
3b85234d918a58ce57758b44c97adbc10008fc4f3095fef31cefdbd56c782ee7

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089132, “Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089132.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089132" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089132" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089132 Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089132 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089132 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089132 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089132", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1151 }, "figures": [], "files": [ { "bytes": 18689, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "cd24ac63ef59fcb6116e400b277028c0ed9bf386b3bd987c3341466f3dc19344" }, { "bytes": 8226, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "66f64f7d2e7537eb077a2d9e5af2544a7c8b7dd858efa43a8bbe62c26668f23d" }, { "bytes": 7896, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3b85234d918a58ce57758b44c97adbc10008fc4f3095fef31cefdbd56c782ee7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089132/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089132", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-715a-b633-b999a6469933" } DndXz/nwI+YhccKZRryYUNSJu4RLg1ECe/PWMTH46Y1tx/4abOnxM5ue1BpxasrOczAQNUIR52p6xDD3UYoiCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: DndXz/nwI+YhccKZRryYUNSJu4RLg1ECe/PWMTH46Y1tx/4abOnxM5ue1BpxasrOczAQNUIR52p6xDD3UYoiCA== {"files":[{"bytes":19504,"name":"index.html","sha256":"10b7f9dd475ab293bd1183119b250d812663628eaba2446689213fa788fd2bea"},{"bytes":8927,"name":"publication.md","sha256":"84fd221a6ab250c8155906f4f28bce8c27f0f05a8a99db92ee14e4cb84f18bbb"},{"bytes":8591,"name":"publication.txt","sha256":"2ffdb2cb198adb2accc4c41844e84192f71035880bf9b0e2cea390ef5a197617"},{"bytes":2850,"name":"manifest.json","sha256":"1f7f573e91d54735443566f9a8521eae0db162c9ad2d2b86c6c73eb3298be8a1"},{"bytes":89,"name":"manifest.sig","sha256":"646b2909b6d69073bd4392c886014f490acbd7eac41b0e06069b37bc3b623ade"},{"bytes":227,"name":"manifest.sig.txt","sha256":"70117b9a47bc8631d336f26763a17a724563d6558b56a84440c856f9fda54223"}],"publication_id":"OT-2026-000089133"} Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089133
OpenTechnical

OT-2026-000089133

Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
2ffdb2cb198adb2accc4c41844e84192f71035880bf9b0e2cea390ef5a197617

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089133, “Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089133.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089133" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089133" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089133 Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089133 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089133 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089133 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089133", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1257 }, "figures": [], "files": [ { "bytes": 19504, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "10b7f9dd475ab293bd1183119b250d812663628eaba2446689213fa788fd2bea" }, { "bytes": 8927, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "84fd221a6ab250c8155906f4f28bce8c27f0f05a8a99db92ee14e4cb84f18bbb" }, { "bytes": 8591, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2ffdb2cb198adb2accc4c41844e84192f71035880bf9b0e2cea390ef5a197617" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089133/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089133", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7fdb-b4d2-e3e60b16ae8f" } cuzmahyvZwkjn8nOzXYKLhLIw++7idclTHxfo1riRejtaY8c07GWaLV3zkPWLnZLV/38vrTQ/i0+ITkO3dHbAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: cuzmahyvZwkjn8nOzXYKLhLIw++7idclTHxfo1riRejtaY8c07GWaLV3zkPWLnZLV/38vrTQ/i0+ITkO3dHbAg== {"files":[{"bytes":19251,"name":"index.html","sha256":"a6cca7ea9884443c492c3eb1f297de14a11b952359a07fcb0d23c8cc681edb0b"},{"bytes":8717,"name":"publication.md","sha256":"17f5cf452f153abe2891120d3791795c036779963ca1f613158e71a4ff14623b"},{"bytes":8381,"name":"publication.txt","sha256":"0306237e5abbe8546a9b6f70457b9e4057642ff53f1ddb80496f781a811e1c55"},{"bytes":2850,"name":"manifest.json","sha256":"d84c9b8b47f18f78282bc222fc12b25fd71b6ba3f18488bd897b6f3deb07080c"},{"bytes":89,"name":"manifest.sig","sha256":"28ce6f7fc5142daf7e4b2ab99999704c995c84ca947a0b81b8217919796626fc"},{"bytes":227,"name":"manifest.sig.txt","sha256":"5261f41686818ed225d2574c8c5388eae54afc2df5fc2807f399a276f9353a50"}],"publication_id":"OT-2026-000089134"} Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089134
OpenTechnical

OT-2026-000089134

Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
0306237e5abbe8546a9b6f70457b9e4057642ff53f1ddb80496f781a811e1c55

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089134, “Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089134.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089134" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089134" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089134 Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089134 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089134 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089134 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089134", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1222 }, "figures": [], "files": [ { "bytes": 19251, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a6cca7ea9884443c492c3eb1f297de14a11b952359a07fcb0d23c8cc681edb0b" }, { "bytes": 8717, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "17f5cf452f153abe2891120d3791795c036779963ca1f613158e71a4ff14623b" }, { "bytes": 8381, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0306237e5abbe8546a9b6f70457b9e4057642ff53f1ddb80496f781a811e1c55" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089134/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089134", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7c61-bc44-7986e442e894" } 8m28Ko1xl7ew3T+IoWLHl7ZBSXbbJDdyAl5DU/x8Yfy2bgn3yR+ciw08Nn/olZAWLSVureeJp14njavWew8gAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 8m28Ko1xl7ew3T+IoWLHl7ZBSXbbJDdyAl5DU/x8Yfy2bgn3yR+ciw08Nn/olZAWLSVureeJp14njavWew8gAg== {"files":[{"bytes":18635,"name":"index.html","sha256":"7a428d6eca8c52e14e53ba421b332dcc8eaa80f86b8985563e5522254fa861c7"},{"bytes":8172,"name":"publication.md","sha256":"3cb63567eba97990a4ffa6710bd64cfc9576456edd748b71d8d136dba94e3a14"},{"bytes":7842,"name":"publication.txt","sha256":"2af25aeb8b7384faec1f82e314fe1c86abe524fb1e0a3a30e55e4f2e748eb043"},{"bytes":2838,"name":"manifest.json","sha256":"d005f1e280c4f7ea2bca6186dd154c91203c6015cd5ffb9034b9284b205999b5"},{"bytes":89,"name":"manifest.sig","sha256":"283e69dcf91f3042e0ac16bb4c341749e87335d7132b9970f2f17bbf9473ad9e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"568dbaae5454cca4347a40803915b5ca2b56ac365211ba9f1d680347d2453afd"}],"publication_id":"OT-2026-000089135"} Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089135
OpenTechnical

OT-2026-000089135

Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
2af25aeb8b7384faec1f82e314fe1c86abe524fb1e0a3a30e55e4f2e748eb043

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089135, “Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089135.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089135" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089135" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089135 Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089135 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089135 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089135 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089135", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1136 }, "figures": [], "files": [ { "bytes": 18635, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7a428d6eca8c52e14e53ba421b332dcc8eaa80f86b8985563e5522254fa861c7" }, { "bytes": 8172, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3cb63567eba97990a4ffa6710bd64cfc9576456edd748b71d8d136dba94e3a14" }, { "bytes": 7842, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2af25aeb8b7384faec1f82e314fe1c86abe524fb1e0a3a30e55e4f2e748eb043" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089135/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089135", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7f04-ae4d-62bd6af8d2fd" } vTVuLbIwZyvBoM1LuTt9CJurwi5+o99aj5ycyJHji/f+e5oIjgdIiGv+Dbta8javb0sNBf+dmtNXgGoVQJMtDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: vTVuLbIwZyvBoM1LuTt9CJurwi5+o99aj5ycyJHji/f+e5oIjgdIiGv+Dbta8javb0sNBf+dmtNXgGoVQJMtDw== {"files":[{"bytes":19450,"name":"index.html","sha256":"9771288266aa408cc51b8ce46f456f48ae7c73c9f9d0a85283de6ff69f2dda72"},{"bytes":8873,"name":"publication.md","sha256":"98bc91b92880d8118e641ac20deab5371ea68c51e4da651368b969601d766992"},{"bytes":8537,"name":"publication.txt","sha256":"d428a41fc66400a90b06b7d0877c4239e86c372ab71bd949d90b816305ea2394"},{"bytes":2850,"name":"manifest.json","sha256":"2f8e6ec02b3ff0151a8dfc8244c9aaac8cdb03518f6659c8f866239e104ac459"},{"bytes":89,"name":"manifest.sig","sha256":"6e633482ef9ec26563415da73b2a90dd96186d281f64b97b0cc39d1ae31fd5d3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"793ca32c272e6ca5f268f5cb3a0d657e1acdd25a5a33b2541a4de674d79baf67"}],"publication_id":"OT-2026-000089136"} Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089136
OpenTechnical

OT-2026-000089136

Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
d428a41fc66400a90b06b7d0877c4239e86c372ab71bd949d90b816305ea2394

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089136, “Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089136.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089136" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089136" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089136 Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089136 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089136 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089136 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089136", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1242 }, "figures": [], "files": [ { "bytes": 19450, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9771288266aa408cc51b8ce46f456f48ae7c73c9f9d0a85283de6ff69f2dda72" }, { "bytes": 8873, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "98bc91b92880d8118e641ac20deab5371ea68c51e4da651368b969601d766992" }, { "bytes": 8537, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d428a41fc66400a90b06b7d0877c4239e86c372ab71bd949d90b816305ea2394" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089136/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089136", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7803-9928-057a5642eaed" } 5d4PxQTbCGe+FkQuPSROVx52F/H0FReVNu5eN5aP1YtIpKxhV+TxKoQPg0rOl/NZSK9ag4HDiwgx/spTJsC4Dw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 5d4PxQTbCGe+FkQuPSROVx52F/H0FReVNu5eN5aP1YtIpKxhV+TxKoQPg0rOl/NZSK9ag4HDiwgx/spTJsC4Dw== {"files":[{"bytes":19197,"name":"index.html","sha256":"f4e6b52e19a41488f911f15f76fa99d0cc485d99c93f14fcecb6117f78ab5e9f"},{"bytes":8663,"name":"publication.md","sha256":"61b8b9bd15cf8feb009d73654ddcaf44a6a6c071a51446c4af80248d592f911c"},{"bytes":8327,"name":"publication.txt","sha256":"d076f69ebe9f058a48d968e9a74dabbdd571e283a1e5250df317553d8ce7dcce"},{"bytes":2850,"name":"manifest.json","sha256":"935b887b3f4deccdad31bd55aed3289883ffe862051ea979137c87047a729a77"},{"bytes":89,"name":"manifest.sig","sha256":"7602c8fe41e8e9e8c6208d34428870594aa0ed45ef687127b4ba69352f88fc4d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"64cd3e389f8dc650c2d91ffefcba7844b979e80ae5065aa712d2754e1f95ba9d"}],"publication_id":"OT-2026-000089137"} Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089137
OpenTechnical

OT-2026-000089137

Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
d076f69ebe9f058a48d968e9a74dabbdd571e283a1e5250df317553d8ce7dcce

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089137, “Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089137.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089137" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089137" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089137 Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089137 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089137 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089137 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089137", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1207 }, "figures": [], "files": [ { "bytes": 19197, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f4e6b52e19a41488f911f15f76fa99d0cc485d99c93f14fcecb6117f78ab5e9f" }, { "bytes": 8663, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "61b8b9bd15cf8feb009d73654ddcaf44a6a6c071a51446c4af80248d592f911c" }, { "bytes": 8327, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d076f69ebe9f058a48d968e9a74dabbdd571e283a1e5250df317553d8ce7dcce" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089137/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089137", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7401-ae6e-7573493ef105" } 3efVKN6FZ2bfluJLumbtVrEG3fo95+cj+Lam6jJUKIu33ToAcMykksL8qsuA2YsGCeLqV0yS3WoZHkVt9eV5Cg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 3efVKN6FZ2bfluJLumbtVrEG3fo95+cj+Lam6jJUKIu33ToAcMykksL8qsuA2YsGCeLqV0yS3WoZHkVt9eV5Cg== {"files":[{"bytes":18405,"name":"index.html","sha256":"103cbb723c257926eb296ce990a8d3059268a2f6422824806fc9e3afff7b21f0"},{"bytes":7986,"name":"publication.md","sha256":"992b53530478891c6cb5198169591bb20c84f8b35521aaed56667cde4f7a5f9c"},{"bytes":7652,"name":"publication.txt","sha256":"36cac16a0ebba8fe54e4d8e599ca6b7bd1bb001f1a52606070227652e4ecbc80"},{"bytes":2855,"name":"manifest.json","sha256":"42199d557d3a8f24ec03724c89869edd29912e5690ed30bb17ea07280884ea88"},{"bytes":89,"name":"manifest.sig","sha256":"f75c5f304ec7f5968c7094ccc776e32e341fbe6055aa57870cee8bdbb0c992bc"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f7310672e0839d77188c63c16dd5a64dcb436e2ec385e87d118fc3847361457d"}],"publication_id":"OT-2026-000089138"} Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089138
OpenTechnical

OT-2026-000089138

Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
36cac16a0ebba8fe54e4d8e599ca6b7bd1bb001f1a52606070227652e4ecbc80

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089138, “Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089138.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089138" title: "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089138" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089138 Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089138 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089138 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089138 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089138", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18405, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "103cbb723c257926eb296ce990a8d3059268a2f6422824806fc9e3afff7b21f0" }, { "bytes": 7986, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "992b53530478891c6cb5198169591bb20c84f8b35521aaed56667cde4f7a5f9c" }, { "bytes": 7652, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "36cac16a0ebba8fe54e4d8e599ca6b7bd1bb001f1a52606070227652e4ecbc80" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089138/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089138", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7755-8704-e47b8dc492d3" } SPu+E14ZP9znAn3nvzs5e6snKH3aEpQ1BVfxux0emTqBqFBB5jOEEFZEThpPMfqFIMX9zJ7J4NPZeSbErzPqBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: SPu+E14ZP9znAn3nvzs5e6snKH3aEpQ1BVfxux0emTqBqFBB5jOEEFZEThpPMfqFIMX9zJ7J4NPZeSbErzPqBg== {"files":[{"bytes":19220,"name":"index.html","sha256":"aec6219c35a9c678330016087917a0c5e581a6ca335f8f66c8e0d955c5fbb643"},{"bytes":8687,"name":"publication.md","sha256":"9ea5ac1ae8939684512bd4ff23ba4e59a6bec82687b84d32f1e5d46bdfb17f1c"},{"bytes":8347,"name":"publication.txt","sha256":"8714f6fd7f4afda9976b58452f62d38e12a0b706fd8f11b538624d304c18da19"},{"bytes":2867,"name":"manifest.json","sha256":"bd7c7b33b68674ebe9289fa4f18549be659e6c39e6f9641acda914f738642240"},{"bytes":89,"name":"manifest.sig","sha256":"129acdf0660782129cc1e508834db5ddd4f5950fc4175e472088445b6789c23e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a910da5891aeb8e62bcfe60421495559dd50cbcc47c8dbffb69b819120feb8b0"}],"publication_id":"OT-2026-000089139"} Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089139
OpenTechnical

OT-2026-000089139

Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8714f6fd7f4afda9976b58452f62d38e12a0b706fd8f11b538624d304c18da19

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089139, “Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089139.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089139" title: "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089139" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089139 Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089139 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089139 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089139 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089139", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19220, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "aec6219c35a9c678330016087917a0c5e581a6ca335f8f66c8e0d955c5fbb643" }, { "bytes": 8687, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9ea5ac1ae8939684512bd4ff23ba4e59a6bec82687b84d32f1e5d46bdfb17f1c" }, { "bytes": 8347, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8714f6fd7f4afda9976b58452f62d38e12a0b706fd8f11b538624d304c18da19" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089139/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089139", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-70b7-b9f5-6c6b5b0e42a8" } uiFMMdQGXnGifxiUI37qF2iff65/3AZYScifAkCackKJqfatIlgOjXExjUl6M/K/oB6I3mLihxfayulw+XelDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: uiFMMdQGXnGifxiUI37qF2iff65/3AZYScifAkCackKJqfatIlgOjXExjUl6M/K/oB6I3mLihxfayulw+XelDA== {"files":[{"bytes":18967,"name":"index.html","sha256":"9e533092b2cfca04173a4c1c018b588bbe4d7598f1bd49e1c5483d37ac1b460c"},{"bytes":8477,"name":"publication.md","sha256":"cde1e673b7f54d31821453e8f17295f5c41fca93ed7a0fd03f599cb591245b40"},{"bytes":8137,"name":"publication.txt","sha256":"a99ba62e1dcb0bf3745e2dff95d5f3b8ff6d3d90ec5d1eba84c626f7cffa6d47"},{"bytes":2867,"name":"manifest.json","sha256":"9e05bbd76e3bfb2f8f09820e61c8be45b23c8a6cd9ce882bbf2c39a1c1cdf1c0"},{"bytes":89,"name":"manifest.sig","sha256":"0dc8f016282190b7fe806e6b24c1e3646accb46b111c8f9de45642b2e6e35d61"},{"bytes":227,"name":"manifest.sig.txt","sha256":"59c1bac766f6fb246f1de1d184777f069a5a7eb7924ef1337b100a47b15c6eed"}],"publication_id":"OT-2026-000089140"} Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089140
OpenTechnical

OT-2026-000089140

Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a99ba62e1dcb0bf3745e2dff95d5f3b8ff6d3d90ec5d1eba84c626f7cffa6d47

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089140, “Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089140.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089140" title: "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089140" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089140 Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089140 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089140 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089140 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089140", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18967, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9e533092b2cfca04173a4c1c018b588bbe4d7598f1bd49e1c5483d37ac1b460c" }, { "bytes": 8477, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cde1e673b7f54d31821453e8f17295f5c41fca93ed7a0fd03f599cb591245b40" }, { "bytes": 8137, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a99ba62e1dcb0bf3745e2dff95d5f3b8ff6d3d90ec5d1eba84c626f7cffa6d47" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089140/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089140", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7e75-81bf-c202903fa62f" } mNSTBHaT53n2br95Ny06KgCoEPCG4M+4KV9mlBCVLpvaInM8+Vw8M/wprvuSGp37XKtVpqTo3+xOOepdrv24Bw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: mNSTBHaT53n2br95Ny06KgCoEPCG4M+4KV9mlBCVLpvaInM8+Vw8M/wprvuSGp37XKtVpqTo3+xOOepdrv24Bw== {"files":[{"bytes":18405,"name":"index.html","sha256":"b5f1fe2ea8ddead8237b474c5aa5a88b9ea989b02b6d6ead0634911617dd4f88"},{"bytes":7986,"name":"publication.md","sha256":"2d0fe883f90429e949562633abd6a3828b6e9504ac7150d08f4ad1062fd47ac5"},{"bytes":7652,"name":"publication.txt","sha256":"dac0c41b6cc67ada0d57b6a6cb18b276aa4afb2c07c61503ce6b3e97e7c0d11a"},{"bytes":2855,"name":"manifest.json","sha256":"5351b060eab23c3bfe3da69e11dd16577ed74b1e670d331add60ebcdc6c67b07"},{"bytes":89,"name":"manifest.sig","sha256":"a36e62a81956143178a5b9e82b75f31580dcfeac4e3228703b199b6b1bfb2eaf"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e2ccc4f985291e6f4aaaa4e412f2bdf25121fe2d6a8db2ce6471d636af7fa39c"}],"publication_id":"OT-2026-000089141"} Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089141
OpenTechnical

OT-2026-000089141

Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
dac0c41b6cc67ada0d57b6a6cb18b276aa4afb2c07c61503ce6b3e97e7c0d11a

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089141, “Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089141.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089141" title: "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089141" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089141 Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089141 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089141 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089141 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089141", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18405, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b5f1fe2ea8ddead8237b474c5aa5a88b9ea989b02b6d6ead0634911617dd4f88" }, { "bytes": 7986, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "2d0fe883f90429e949562633abd6a3828b6e9504ac7150d08f4ad1062fd47ac5" }, { "bytes": 7652, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "dac0c41b6cc67ada0d57b6a6cb18b276aa4afb2c07c61503ce6b3e97e7c0d11a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089141/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089141", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7102-820e-84e1386ff7fe" } vx+7Ghuei4n0dhj0cE0UtoOhWyNKsvtS2XhRI3JqNb1V++5raFK5LClSXL/NbHXwx11rN35JpeOBQcD+aj8DBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: vx+7Ghuei4n0dhj0cE0UtoOhWyNKsvtS2XhRI3JqNb1V++5raFK5LClSXL/NbHXwx11rN35JpeOBQcD+aj8DBQ== {"files":[{"bytes":19220,"name":"index.html","sha256":"890af297a7876d918719b8d568bdc28d8cc8e3fe7d26a1f5ea4567591e022d99"},{"bytes":8687,"name":"publication.md","sha256":"46b21a6d76f0e4a8940d5c54e14367c6fbd50ea0c19a7b65f2fbf69893dafc3f"},{"bytes":8347,"name":"publication.txt","sha256":"346f88747c721e950075c02947ac512b6a21f79c3f72d0c5da6c8a72406e8fc4"},{"bytes":2867,"name":"manifest.json","sha256":"c523fbbe9f1b613cc4da708689eacfe7788344c60cdbc5a1f45b803098e99831"},{"bytes":89,"name":"manifest.sig","sha256":"8d328fbb50187f3e9d2887cedc82c1a40626d0d43e03f39841b19f4105b13227"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8f9d344ef60f6fd0ae8fed0824d76b4b2962bca7d57c1d032294d68267467628"}],"publication_id":"OT-2026-000089142"} Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089142
OpenTechnical

OT-2026-000089142

Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
346f88747c721e950075c02947ac512b6a21f79c3f72d0c5da6c8a72406e8fc4

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089142, “Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089142.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089142" title: "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089142" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089142 Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089142 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089142 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089142 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089142", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19220, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "890af297a7876d918719b8d568bdc28d8cc8e3fe7d26a1f5ea4567591e022d99" }, { "bytes": 8687, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "46b21a6d76f0e4a8940d5c54e14367c6fbd50ea0c19a7b65f2fbf69893dafc3f" }, { "bytes": 8347, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "346f88747c721e950075c02947ac512b6a21f79c3f72d0c5da6c8a72406e8fc4" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089142/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089142", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-794d-8d99-1df25e3c0f9f" } jQuX4TQ6qujEUKJFqSMpTWwo8wgUGOvjL1UvOWMhaEg/84/BEiXkJGNQVtEfDHtAxcVK+hqByBaFZWX08LTnAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: jQuX4TQ6qujEUKJFqSMpTWwo8wgUGOvjL1UvOWMhaEg/84/BEiXkJGNQVtEfDHtAxcVK+hqByBaFZWX08LTnAQ== {"files":[{"bytes":18967,"name":"index.html","sha256":"4c9d943ed6eda84f1576769b5a6d2f9396c6c58a71297d58a02fb0a8bf2e9309"},{"bytes":8477,"name":"publication.md","sha256":"e0ec88d43d5b0777327d8592b99768a99d9c464637c536863b4af079f3ec1386"},{"bytes":8137,"name":"publication.txt","sha256":"da2905ade9a46756f04a7255813f63dfa03f84ee78c3603bf00ed62969b945b5"},{"bytes":2867,"name":"manifest.json","sha256":"f92183fb2840341aad5acf24716db01029094961e3e076d4f774dca0f1cde860"},{"bytes":89,"name":"manifest.sig","sha256":"9e6c05f3f5ef4567b216a22468ba8a1da69180893ded71cb59dd43c3a405bf0c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"41e2c5e6aa44a904098b0189d0f7e23d62a7313f79cc4851f1df854ea34c0118"}],"publication_id":"OT-2026-000089143"} Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089143
OpenTechnical

OT-2026-000089143

Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
da2905ade9a46756f04a7255813f63dfa03f84ee78c3603bf00ed62969b945b5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089143, “Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089143.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089143" title: "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089143" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089143 Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089143 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089143 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089143 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089143", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18967, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4c9d943ed6eda84f1576769b5a6d2f9396c6c58a71297d58a02fb0a8bf2e9309" }, { "bytes": 8477, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e0ec88d43d5b0777327d8592b99768a99d9c464637c536863b4af079f3ec1386" }, { "bytes": 8137, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "da2905ade9a46756f04a7255813f63dfa03f84ee78c3603bf00ed62969b945b5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089143/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089143", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-712e-8447-5c365d88f0aa" } l8CWD+nTrnDEvqwd56MJWQ6zTk7w6tH+HOjaogECGv++Z39GAt4p/Y0F7B9ObDoe//tUshFLtRYNgjTwHtEgDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: l8CWD+nTrnDEvqwd56MJWQ6zTk7w6tH+HOjaogECGv++Z39GAt4p/Y0F7B9ObDoe//tUshFLtRYNgjTwHtEgDw== {"files":[{"bytes":18418,"name":"index.html","sha256":"ce77ff288997e51ee44f19d3586c5593efec938fe3911db13e560f043fb8935f"},{"bytes":8052,"name":"publication.md","sha256":"48a9baee3131b01bbc8fc966f703d825f00ecf6e5416ab26a955dd85685078cc"},{"bytes":7690,"name":"publication.txt","sha256":"b4a3f90ba31bf22b8d64bc28ffce84fd0eea52c6404a35c6a9d17ad71f76541a"},{"bytes":2915,"name":"manifest.json","sha256":"8760c6feeef591b8fd0c8e7b8d1bf5620d2092b65f89f3c0109802cbedd7f827"},{"bytes":89,"name":"manifest.sig","sha256":"977a5ebcf135d0f17eeb486b6e5a8d80b35b9f70c121a95e5bfb10909263a846"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c5f2a9f249bf2fceb2ffe342d232e34f7a9a6ac03de1d6a21cc6118f162e3c2a"}],"publication_id":"OT-2026-000089144"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089144
OpenTechnical

OT-2026-000089144

Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
b4a3f90ba31bf22b8d64bc28ffce84fd0eea52c6404a35c6a9d17ad71f76541a

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089144, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089144.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089144" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089144" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089144 Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089144 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089144 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089144 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089144", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1096 }, "figures": [], "files": [ { "bytes": 18418, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ce77ff288997e51ee44f19d3586c5593efec938fe3911db13e560f043fb8935f" }, { "bytes": 8052, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "48a9baee3131b01bbc8fc966f703d825f00ecf6e5416ab26a955dd85685078cc" }, { "bytes": 7690, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b4a3f90ba31bf22b8d64bc28ffce84fd0eea52c6404a35c6a9d17ad71f76541a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089144/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089144", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-734e-9fa7-187a0c380096" } zK1dwYGi017gQYqNPYJa56OiUZ8XyQAU4CUA/SpuVKEUPw5mViMjOWheOJqGtG62o32JMcwRUZHN5No6eRdXCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: zK1dwYGi017gQYqNPYJa56OiUZ8XyQAU4CUA/SpuVKEUPw5mViMjOWheOJqGtG62o32JMcwRUZHN5No6eRdXCg== {"files":[{"bytes":19224,"name":"index.html","sha256":"a5a82cf6c4608a00665c2b3ad288beb34b460058fa605139ee16cc84c9d31668"},{"bytes":8740,"name":"publication.md","sha256":"c08e6964544330cbe81337d218f254ad36ee337de98e12df7efb61da142e3fff"},{"bytes":8379,"name":"publication.txt","sha256":"8ba9d3b4868280c8e230cd6aa94360f5cf06103a1a97a30a37934c6d62e65bf6"},{"bytes":2920,"name":"manifest.json","sha256":"8e5d1bb06e37b6ff6dd7adcc0bc4963d879486496a31438eb07cad79401dbfab"},{"bytes":89,"name":"manifest.sig","sha256":"b6da5bbea0208e686a2f3ea0f086480bf808240856249246a8a5faa61501140a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1df2433bce496407f925cba6fa76aa329cffc2c0eaae564a9122ce55466f532f"}],"publication_id":"OT-2026-000089145"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089145
OpenTechnical

OT-2026-000089145

Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8ba9d3b4868280c8e230cd6aa94360f5cf06103a1a97a30a37934c6d62e65bf6

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089145, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089145.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089145" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089145" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089145 Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089145 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089145 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089145 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089145", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19224, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a5a82cf6c4608a00665c2b3ad288beb34b460058fa605139ee16cc84c9d31668" }, { "bytes": 8740, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c08e6964544330cbe81337d218f254ad36ee337de98e12df7efb61da142e3fff" }, { "bytes": 8379, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8ba9d3b4868280c8e230cd6aa94360f5cf06103a1a97a30a37934c6d62e65bf6" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089145/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089145", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-76e8-bcb6-80ebe61eba76" } NKpPPxIQUTkEQn4z/g/Bxpa851G5Xmkr+Qwa9ShVI7EH1hiroGKHqba69yFNfRXfuEG6n+nGPV9qrNQxI1aNCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: NKpPPxIQUTkEQn4z/g/Bxpa851G5Xmkr+Qwa9ShVI7EH1hiroGKHqba69yFNfRXfuEG6n+nGPV9qrNQxI1aNCA== {"files":[{"bytes":18971,"name":"index.html","sha256":"d9cf70f7016d867ab7cf495c7de4e906e6d7f072dce2fb464671e886a67b4968"},{"bytes":8530,"name":"publication.md","sha256":"1102da1ea3fd000838dfffba75dc7143b5919475864f896f67b3a3dad0443a28"},{"bytes":8169,"name":"publication.txt","sha256":"1ecf5ea0b0db2111826bedabe164496d1ceb09a83fa46f1685a0f03b9fc2d8da"},{"bytes":2920,"name":"manifest.json","sha256":"c708e588aec104bbe6cc61555692bac388e4b93eeb7be53fbb4c19fa5818ca66"},{"bytes":89,"name":"manifest.sig","sha256":"f6aeca04a3d9e532a8c3e8b3bdff3701eecd8021274875ea97b83eb1a987bd6c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"627dd2a3489d50fe7c079e2d425626e0d3f568394d46e3beae66bef103f1f876"}],"publication_id":"OT-2026-000089146"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089146
OpenTechnical

OT-2026-000089146

Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
1ecf5ea0b0db2111826bedabe164496d1ceb09a83fa46f1685a0f03b9fc2d8da

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089146, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089146.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089146" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089146" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089146 Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089146 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089146 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089146 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089146", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1167 }, "figures": [], "files": [ { "bytes": 18971, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d9cf70f7016d867ab7cf495c7de4e906e6d7f072dce2fb464671e886a67b4968" }, { "bytes": 8530, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1102da1ea3fd000838dfffba75dc7143b5919475864f896f67b3a3dad0443a28" }, { "bytes": 8169, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1ecf5ea0b0db2111826bedabe164496d1ceb09a83fa46f1685a0f03b9fc2d8da" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089146/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089146", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7c94-b599-ebe0e2323d4d" } hfiVKpiwh1fZxBNnE1P9skNaA36so0csQrnbevJhGdT9iWvqTbkfmvoKs7k6JS/unzI+5UIbWSj1HhPsS0jHBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: hfiVKpiwh1fZxBNnE1P9skNaA36so0csQrnbevJhGdT9iWvqTbkfmvoKs7k6JS/unzI+5UIbWSj1HhPsS0jHBQ== {"files":[{"bytes":18419,"name":"index.html","sha256":"b04d53c8ff857e0be2e0b7119304e98183c88fa92d97ad6d5921186442b80105"},{"bytes":8053,"name":"publication.md","sha256":"b36fbfcae1767fd173d06566a9ee36d84b9dd6589dd0097bb664e65f17f32725"},{"bytes":7691,"name":"publication.txt","sha256":"ba87242005ca31a60a6e9006e70eb2eac955be35373e7e2ae909670512bec93b"},{"bytes":2915,"name":"manifest.json","sha256":"c7f831f2feb53a46b5c97d98aaf9579fd417576b4d09accfc26825323dfe812b"},{"bytes":89,"name":"manifest.sig","sha256":"9039586001bcf57100a2a8d6f028c0492638df7bcf09402178f00c59bfbeeae5"},{"bytes":227,"name":"manifest.sig.txt","sha256":"edb8c30d3d336a60196f48c9d18f5999a02a8f0aaff698740dedcaaaab509425"}],"publication_id":"OT-2026-000089147"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089147
OpenTechnical

OT-2026-000089147

Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
ba87242005ca31a60a6e9006e70eb2eac955be35373e7e2ae909670512bec93b

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089147, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089147.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089147" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089147" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089147 Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089147 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089147 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089147 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089147", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1096 }, "figures": [], "files": [ { "bytes": 18419, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b04d53c8ff857e0be2e0b7119304e98183c88fa92d97ad6d5921186442b80105" }, { "bytes": 8053, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b36fbfcae1767fd173d06566a9ee36d84b9dd6589dd0097bb664e65f17f32725" }, { "bytes": 7691, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ba87242005ca31a60a6e9006e70eb2eac955be35373e7e2ae909670512bec93b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089147/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089147", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-74a7-bb27-2db907a219dc" } KFX3kk5L82ZSatKbYdflt2s/66chUATWC3CMcg8xLi87wFVKNUtInxayVKmIo8mZT2ua384BsKAjOl+BRdPcBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: KFX3kk5L82ZSatKbYdflt2s/66chUATWC3CMcg8xLi87wFVKNUtInxayVKmIo8mZT2ua384BsKAjOl+BRdPcBQ== {"files":[{"bytes":19225,"name":"index.html","sha256":"5e4b877e701a5af4478e3ac5ed2f591522b7dd02bd36f99b36c2760719173b99"},{"bytes":8741,"name":"publication.md","sha256":"8c59128e88b0e7c499a4118ebd2d7b1910d8d010b60e4dc2bab6b3010d089382"},{"bytes":8380,"name":"publication.txt","sha256":"c7a0b82b6b9d94dee05d98d2fd9d656b04429e506b5becb87ac34096880a71ea"},{"bytes":2920,"name":"manifest.json","sha256":"d820dbc277b110e1b6120d5e6c5e788f0e47577b3d15778934fcbd44011ca4f1"},{"bytes":89,"name":"manifest.sig","sha256":"75456707c6f5507a7a98e3edafd59061a4c069f0e4c527e30b57c369376501b9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a5aa5f80d24afe639264f88b3abdf1d71ccf65eb76ce689a50a9d9e74aa069bc"}],"publication_id":"OT-2026-000089148"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089148
OpenTechnical

OT-2026-000089148

Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c7a0b82b6b9d94dee05d98d2fd9d656b04429e506b5becb87ac34096880a71ea

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089148, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089148.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089148" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089148" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089148 Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089148 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089148 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089148 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089148", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19225, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5e4b877e701a5af4478e3ac5ed2f591522b7dd02bd36f99b36c2760719173b99" }, { "bytes": 8741, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8c59128e88b0e7c499a4118ebd2d7b1910d8d010b60e4dc2bab6b3010d089382" }, { "bytes": 8380, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c7a0b82b6b9d94dee05d98d2fd9d656b04429e506b5becb87ac34096880a71ea" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089148/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089148", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7fcb-bf6a-30d291dd8bc3" } nqJSeFInOBACq3IMP1I110eK/WMOa4yg7K//vSRrbTUIUicLtV6f4tFY1rJP1QGJ+oCT7KjtHpUWTozWVEs9CA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: nqJSeFInOBACq3IMP1I110eK/WMOa4yg7K//vSRrbTUIUicLtV6f4tFY1rJP1QGJ+oCT7KjtHpUWTozWVEs9CA== {"files":[{"bytes":18972,"name":"index.html","sha256":"c5f40cd3229a8d8b901204a2b35527ed986f0302354e30949e4afb646c7be27c"},{"bytes":8531,"name":"publication.md","sha256":"f8e9381bdaa9e3fda09071653694e160361ec5253d149edd4a0cf50201696583"},{"bytes":8170,"name":"publication.txt","sha256":"7e0542a45330364e37f62be595b4513ff9b66f4764f3cddc9ab666fb376d0c31"},{"bytes":2920,"name":"manifest.json","sha256":"56e0f3703579ab4546e63f7efb7afddcc3c5d883bc79230694e45989eb644187"},{"bytes":89,"name":"manifest.sig","sha256":"0a60f2b9a8adc9222348883ba6ae897916063a33946abb99171345402c97ac73"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4a2968c6923ccc92216312274657fc0f4880a143584d323e41f3237cf5d7ec2d"}],"publication_id":"OT-2026-000089149"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089149
OpenTechnical

OT-2026-000089149

Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7e0542a45330364e37f62be595b4513ff9b66f4764f3cddc9ab666fb376d0c31

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089149, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089149.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089149" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089149" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089149 Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089149 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089149 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089149 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089149", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1167 }, "figures": [], "files": [ { "bytes": 18972, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c5f40cd3229a8d8b901204a2b35527ed986f0302354e30949e4afb646c7be27c" }, { "bytes": 8531, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f8e9381bdaa9e3fda09071653694e160361ec5253d149edd4a0cf50201696583" }, { "bytes": 8170, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7e0542a45330364e37f62be595b4513ff9b66f4764f3cddc9ab666fb376d0c31" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089149/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089149", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7ac8-8a80-0d8c2cf36670" } wW991uv0Rts74Xa/G5DtZ/Mwmzerwcn9NdyzdI2fxCIhboa/b430PZkEZqMpkXT60QnQpaGLO7Bc3L0lFjEVAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: wW991uv0Rts74Xa/G5DtZ/Mwmzerwcn9NdyzdI2fxCIhboa/b430PZkEZqMpkXT60QnQpaGLO7Bc3L0lFjEVAg== {"files":[{"bytes":18423,"name":"index.html","sha256":"0c8967ec4f11fb68499e2623bc0e31478ffb09b67f4b62e51cdb22bb34345637"},{"bytes":8057,"name":"publication.md","sha256":"02eb5b0c76006c4811f402551e75373b85f7e320c17523bacd9d3123966b244e"},{"bytes":7695,"name":"publication.txt","sha256":"1f700ad9ca3f1c3e48a87b55ea884485204c37afca79918d7da3447928cd27ff"},{"bytes":2915,"name":"manifest.json","sha256":"feeee6425feb663f12a70b1d15477752de098cf3aa75ec3fd23083be3009a7a1"},{"bytes":89,"name":"manifest.sig","sha256":"0dec28629ba233171a4126e3a91b5298d59f7bd0143d676aa0deccea45016155"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9cfd905a83e9aa7da3caf14fb0efecb56ebb153c13877c142eedf32e660157a7"}],"publication_id":"OT-2026-000089150"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089150
OpenTechnical

OT-2026-000089150

Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
1f700ad9ca3f1c3e48a87b55ea884485204c37afca79918d7da3447928cd27ff

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089150, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089150.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089150" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089150" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089150 Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089150 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089150 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089150 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089150", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1096 }, "figures": [], "files": [ { "bytes": 18423, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0c8967ec4f11fb68499e2623bc0e31478ffb09b67f4b62e51cdb22bb34345637" }, { "bytes": 8057, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "02eb5b0c76006c4811f402551e75373b85f7e320c17523bacd9d3123966b244e" }, { "bytes": 7695, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1f700ad9ca3f1c3e48a87b55ea884485204c37afca79918d7da3447928cd27ff" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089150/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089150", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7871-858d-e45f349a2483" } crE93w6J1V350RKhqmEBJO7OQjaJggsB5+tOK1RwVIVZDHwzjpIgC+v1d20RJps8rOAHfyaEkNGLjfOA9QozAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: crE93w6J1V350RKhqmEBJO7OQjaJggsB5+tOK1RwVIVZDHwzjpIgC+v1d20RJps8rOAHfyaEkNGLjfOA9QozAw== {"files":[{"bytes":19229,"name":"index.html","sha256":"3bfb34176eb90db65145720a529ed68c2363ad2b5e2251414e9f7265d06f2b96"},{"bytes":8745,"name":"publication.md","sha256":"77eccf0297291de0b2884988634f196c87294c7c2b01397bb2cde2b5f7b15dc3"},{"bytes":8384,"name":"publication.txt","sha256":"c0d67c3514de166fbaa6bdf23935ecf8ee8686d7fdb7298937dafb756e5b2b46"},{"bytes":2920,"name":"manifest.json","sha256":"78febac94e5adaf6903ec6986790c324b45cfea18cbe6d4ab952b5fafae76b11"},{"bytes":89,"name":"manifest.sig","sha256":"4c29acb6e7ab823f1bd093a28594d0a7adc3b75f93d316343199d60ba5d2772f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e1c66f2d96a965dc02074bbd0a1b23c33e3411ce965c2823ddc2d0cdd6fddb1d"}],"publication_id":"OT-2026-000089151"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089151
OpenTechnical

OT-2026-000089151

Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c0d67c3514de166fbaa6bdf23935ecf8ee8686d7fdb7298937dafb756e5b2b46

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089151, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089151.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089151" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089151" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089151 Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089151 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089151 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089151 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089151", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19229, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3bfb34176eb90db65145720a529ed68c2363ad2b5e2251414e9f7265d06f2b96" }, { "bytes": 8745, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "77eccf0297291de0b2884988634f196c87294c7c2b01397bb2cde2b5f7b15dc3" }, { "bytes": 8384, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c0d67c3514de166fbaa6bdf23935ecf8ee8686d7fdb7298937dafb756e5b2b46" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089151/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089151", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-752f-8236-bc3f45e2e2e0" } pWDqv1YauPB1C6glLqQ+KjliH7mZc5RqFogdod0wLgoHJHVtH1hYKtWNpixFHtuEVwoLn4oxXrqYNhFVig1QAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: pWDqv1YauPB1C6glLqQ+KjliH7mZc5RqFogdod0wLgoHJHVtH1hYKtWNpixFHtuEVwoLn4oxXrqYNhFVig1QAg== {"files":[{"bytes":18976,"name":"index.html","sha256":"c5ab803e3254de8e4f24083c15414b905a321ede5a6b4b8685a13b753be9cab3"},{"bytes":8535,"name":"publication.md","sha256":"d3e241a41e518af5619a8921ca3954732133999853ade2a0c0d0922f99768899"},{"bytes":8174,"name":"publication.txt","sha256":"238ab78af4bcc643fd2b3120f63fb58b6be378bb502f157a1df1f975e1d6d8a7"},{"bytes":2920,"name":"manifest.json","sha256":"6616ea853cc07382e2f226f19ccd1bb008c67f00df7532d1173d375f50624143"},{"bytes":89,"name":"manifest.sig","sha256":"f51443c14605d2c050001f3e8561141953c78ce707bd7dd2f8b36b96b4991cd1"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e0b7a248c91a3ce17f526c5343330b681c5411da68d5834862e8612b7004ef30"}],"publication_id":"OT-2026-000089152"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089152
OpenTechnical

OT-2026-000089152

Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
238ab78af4bcc643fd2b3120f63fb58b6be378bb502f157a1df1f975e1d6d8a7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089152, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089152.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089152" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089152" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089152 Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089152 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089152 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089152 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089152", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1167 }, "figures": [], "files": [ { "bytes": 18976, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c5ab803e3254de8e4f24083c15414b905a321ede5a6b4b8685a13b753be9cab3" }, { "bytes": 8535, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d3e241a41e518af5619a8921ca3954732133999853ade2a0c0d0922f99768899" }, { "bytes": 8174, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "238ab78af4bcc643fd2b3120f63fb58b6be378bb502f157a1df1f975e1d6d8a7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089152/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089152", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-718b-bc1a-1d4630cf6116" } Z4IoYKIMfKpvqSYgQmS2CHaeftRd9UaCealEF7Ny+xzvXZqOsJikT2BEh4/rBA7FYIGrVsBZWsVRFKaT1Kx/BQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Z4IoYKIMfKpvqSYgQmS2CHaeftRd9UaCealEF7Ny+xzvXZqOsJikT2BEh4/rBA7FYIGrVsBZWsVRFKaT1Kx/BQ== {"files":[{"bytes":18596,"name":"index.html","sha256":"dd5fab9a48931df10e971774989c6a5272e6212339d12c6299332838fa700b94"},{"bytes":8202,"name":"publication.md","sha256":"40633cc80fffc49d6920328a23579411eab9313e94fa539ad35137dc77bf78be"},{"bytes":7852,"name":"publication.txt","sha256":"828273036ef6e4e0cc45e48db7b1e3a6f5cd3e65a8e993d6f5d7a981efc39e5a"},{"bytes":2890,"name":"manifest.json","sha256":"3b52a6691414f4f9852b668d359da4cad9924c91f4166d6084f72954d0fb7cfe"},{"bytes":89,"name":"manifest.sig","sha256":"a20c530455fe4b7f45c10bbbcca49b5aac05911345bce0d5a599befa525a81ab"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2be3de5a949a79f813b346ec94b7be694e800e0ec676d72e27ef15ce2419740d"}],"publication_id":"OT-2026-000089153"} Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089153
OpenTechnical

OT-2026-000089153

Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
828273036ef6e4e0cc45e48db7b1e3a6f5cd3e65a8e993d6f5d7a981efc39e5a

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089153, “Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089153.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089153" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089153" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089153 Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089153 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089153 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089153 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089153", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1136 }, "figures": [], "files": [ { "bytes": 18596, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "dd5fab9a48931df10e971774989c6a5272e6212339d12c6299332838fa700b94" }, { "bytes": 8202, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "40633cc80fffc49d6920328a23579411eab9313e94fa539ad35137dc77bf78be" }, { "bytes": 7852, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "828273036ef6e4e0cc45e48db7b1e3a6f5cd3e65a8e993d6f5d7a981efc39e5a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089153/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089153", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7f5a-bcee-620f7ecd1ba0" } micTuQKujvphCC/r4WaRc90CWcDE1ByLMH4KRHgWhEQVAanOHTYAgZKlKegxDFusMKW/xfeIy1Y3MgXMxRX7Dg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: micTuQKujvphCC/r4WaRc90CWcDE1ByLMH4KRHgWhEQVAanOHTYAgZKlKegxDFusMKW/xfeIy1Y3MgXMxRX7Dg== {"files":[{"bytes":19402,"name":"index.html","sha256":"5e708f3884bcf3892b3f27a8b7170cbbc724420b52ee2d148f09b5eba4310fd9"},{"bytes":8890,"name":"publication.md","sha256":"5219bb0fc7a6c2fad02397709452ff230e19b3e39586160b0b8785bebc228fa1"},{"bytes":8541,"name":"publication.txt","sha256":"f9439c5cda7ad0d2862b61fb472d4ea1ee1a93acf15494f8529f090150a5dd81"},{"bytes":2895,"name":"manifest.json","sha256":"a312cd06407432e25d673c0c21f88fbfbe8150b8f683093120311d732e1bbf33"},{"bytes":89,"name":"manifest.sig","sha256":"195456ed5d49f864800f1d71a8d809a42c3d52a0e834f4ea6671d590501633a6"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9aa55f047d5a40e5149ef9bbec84684d9e79bb30ed10683e302a82aed5b01f41"}],"publication_id":"OT-2026-000089154"} Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089154
OpenTechnical

OT-2026-000089154

Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f9439c5cda7ad0d2862b61fb472d4ea1ee1a93acf15494f8529f090150a5dd81

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089154, “Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089154.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089154" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089154" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089154 Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089154 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089154 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089154 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089154", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1242 }, "figures": [], "files": [ { "bytes": 19402, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5e708f3884bcf3892b3f27a8b7170cbbc724420b52ee2d148f09b5eba4310fd9" }, { "bytes": 8890, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5219bb0fc7a6c2fad02397709452ff230e19b3e39586160b0b8785bebc228fa1" }, { "bytes": 8541, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f9439c5cda7ad0d2862b61fb472d4ea1ee1a93acf15494f8529f090150a5dd81" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089154/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089154", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7eb9-8ba7-582be1db0bcf" } XX9t2d1Wqd5j9EW32hyAPdIfA0Gde7XDcnCHHb+gPyEkAakX2U1xLMcSJphZqw3ifzPv65eJVpGkGxe3EuJJAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: XX9t2d1Wqd5j9EW32hyAPdIfA0Gde7XDcnCHHb+gPyEkAakX2U1xLMcSJphZqw3ifzPv65eJVpGkGxe3EuJJAQ== {"files":[{"bytes":19149,"name":"index.html","sha256":"6dffced7aa69d199f1cdcd8f34a1fd01a836cd20971c7ac6c9f3f5adb9437626"},{"bytes":8680,"name":"publication.md","sha256":"5597a45742a529770169be3676e9238ecd8cc2a712960b2c1e3aa17579a44be4"},{"bytes":8331,"name":"publication.txt","sha256":"07766b728301d18b7c3be26f6580bc6e6c6693eaa8d0a82148570db261dc2d96"},{"bytes":2895,"name":"manifest.json","sha256":"09ae83f50b23873a0cc9da7881d19a054f02be8bf5fe0717fbca467f1602d04b"},{"bytes":89,"name":"manifest.sig","sha256":"b96052213776a3a0c5bddd68b4f98e361748e1eddfd8d3e799befcffb84d1b3b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7a0002be16ed85ca4d8f97bc7765ca701a4b6afdd39fe1e3b24a6e401078233c"}],"publication_id":"OT-2026-000089155"} Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089155
OpenTechnical

OT-2026-000089155

Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
07766b728301d18b7c3be26f6580bc6e6c6693eaa8d0a82148570db261dc2d96

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089155, “Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089155.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089155" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089155" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089155 Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089155 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089155 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089155 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089155", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1207 }, "figures": [], "files": [ { "bytes": 19149, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6dffced7aa69d199f1cdcd8f34a1fd01a836cd20971c7ac6c9f3f5adb9437626" }, { "bytes": 8680, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5597a45742a529770169be3676e9238ecd8cc2a712960b2c1e3aa17579a44be4" }, { "bytes": 8331, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "07766b728301d18b7c3be26f6580bc6e6c6693eaa8d0a82148570db261dc2d96" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089155/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089155", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-70ae-8c69-ee65477b6f3a" } V8a5QzuX/K5EjdWSmSPPtOH13EBhfs++jupMX3ct9/1Xxzgc5+chJkQnkLnIPRkq5iI8ip94tsVN0d3MoaCGCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: V8a5QzuX/K5EjdWSmSPPtOH13EBhfs++jupMX3ct9/1Xxzgc5+chJkQnkLnIPRkq5iI8ip94tsVN0d3MoaCGCg== {"files":[{"bytes":18542,"name":"index.html","sha256":"f7482db65f18f513d31c947ae13e476601c1ffdb9a3b2f828230921d7f79f312"},{"bytes":8148,"name":"publication.md","sha256":"9a5f141b7628f97225f4c0169e047d3fd706ecf800ab75b03ef07aba05f55fb2"},{"bytes":7798,"name":"publication.txt","sha256":"7fe73bf63f48183bf1b24095a85e9fd2aaef7c46872fd6857e3503df1fccd913"},{"bytes":2890,"name":"manifest.json","sha256":"8073d6df61e2210fb0ebb00f0d3e2b46901c2f7390925ff3f5bc83d76acc6988"},{"bytes":89,"name":"manifest.sig","sha256":"70442341b0ec4082eacac0a100af060cbbb3a4433c07d940a030d91b3d06f8a9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1b7bdefbab47df92c1b7417f69ce893e734413988ad9b7e2bbe8c865302bca59"}],"publication_id":"OT-2026-000089156"} Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089156
OpenTechnical

OT-2026-000089156

Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
7fe73bf63f48183bf1b24095a85e9fd2aaef7c46872fd6857e3503df1fccd913

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089156, “Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089156.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089156" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089156" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089156 Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089156 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089156 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089156 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089156", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1121 }, "figures": [], "files": [ { "bytes": 18542, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f7482db65f18f513d31c947ae13e476601c1ffdb9a3b2f828230921d7f79f312" }, { "bytes": 8148, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9a5f141b7628f97225f4c0169e047d3fd706ecf800ab75b03ef07aba05f55fb2" }, { "bytes": 7798, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7fe73bf63f48183bf1b24095a85e9fd2aaef7c46872fd6857e3503df1fccd913" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089156/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089156", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-70a7-8604-5e24a20918f6" } Akvs3U0l7y0u+C9N5F6mX6WW5iVE0mQ7EHHG6KmlqCVh+fPrsN9Q9gme1rmXidYyryMSl+qUZRAMCKlZ1N0GDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Akvs3U0l7y0u+C9N5F6mX6WW5iVE0mQ7EHHG6KmlqCVh+fPrsN9Q9gme1rmXidYyryMSl+qUZRAMCKlZ1N0GDQ== {"files":[{"bytes":19348,"name":"index.html","sha256":"ea8f73d7d4161824fc864dce386762bb21397fbb3f8cdbd12c207f4e93162b95"},{"bytes":8836,"name":"publication.md","sha256":"29711398b08d1e83afeff2d9fb70ff436372e7428a571275745d23b05d1bae67"},{"bytes":8487,"name":"publication.txt","sha256":"7eeb0b0f206930d81f2fb93af7d46b5eb44c6165a320e5cf3c2315882d5f9b2d"},{"bytes":2895,"name":"manifest.json","sha256":"1a31fb2bc7fce180ee106ee380bcb21ee46091099157f92350aa9c833c0f4bc2"},{"bytes":89,"name":"manifest.sig","sha256":"670cfed3927e210276b225ca879b3888fa8e42c818d4e22da99743929d2346f9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"34a266155b33789facd90f956c3f45a06eb1e182d89e2f20e805ae8f3fb65a82"}],"publication_id":"OT-2026-000089157"} Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089157
OpenTechnical

OT-2026-000089157

Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7eeb0b0f206930d81f2fb93af7d46b5eb44c6165a320e5cf3c2315882d5f9b2d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089157, “Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089157.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089157" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089157" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089157 Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089157 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089157 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089157 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089157", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1227 }, "figures": [], "files": [ { "bytes": 19348, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ea8f73d7d4161824fc864dce386762bb21397fbb3f8cdbd12c207f4e93162b95" }, { "bytes": 8836, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "29711398b08d1e83afeff2d9fb70ff436372e7428a571275745d23b05d1bae67" }, { "bytes": 8487, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7eeb0b0f206930d81f2fb93af7d46b5eb44c6165a320e5cf3c2315882d5f9b2d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089157/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089157", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7775-90fc-482e03252738" } WfPVs54XF4tTqysemFO6pj35dL5yUhV7MbLfpb/7JIeQ3NC44BVi7R/q3MHsbP8S4t84LlfbJkFETyS3sICqBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: WfPVs54XF4tTqysemFO6pj35dL5yUhV7MbLfpb/7JIeQ3NC44BVi7R/q3MHsbP8S4t84LlfbJkFETyS3sICqBw== {"files":[{"bytes":19095,"name":"index.html","sha256":"297ef0e2da17d706e0c1e8dd5b4b6e8a639b3cf750200b537d2ccf1a7a2419c4"},{"bytes":8626,"name":"publication.md","sha256":"fa3a5ac818f6a6a92757a30a140bcf3ba0ed66b1b132f79c431323508cfb1f51"},{"bytes":8277,"name":"publication.txt","sha256":"740f01026f0b388511bd29247c4526d6252307b71fc5973023079713d7300757"},{"bytes":2895,"name":"manifest.json","sha256":"7deb2b7daa51f12cb818ee92d041cdf7d3754a1160bc75f87c39412b4d105ed9"},{"bytes":89,"name":"manifest.sig","sha256":"19b889ddf55586894aed39c112bfba7b83a64565a56096d6f7bab9893aea7a7b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"de53775eb0545aa721e64c23d964efa699f4fb0b5bd72ee76ea4c198aac373f5"}],"publication_id":"OT-2026-000089158"} Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089158
OpenTechnical

OT-2026-000089158

Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
740f01026f0b388511bd29247c4526d6252307b71fc5973023079713d7300757

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089158, “Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089158.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089158" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089158" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089158 Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089158 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089158 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089158 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089158", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1192 }, "figures": [], "files": [ { "bytes": 19095, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "297ef0e2da17d706e0c1e8dd5b4b6e8a639b3cf750200b537d2ccf1a7a2419c4" }, { "bytes": 8626, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fa3a5ac818f6a6a92757a30a140bcf3ba0ed66b1b132f79c431323508cfb1f51" }, { "bytes": 8277, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "740f01026f0b388511bd29247c4526d6252307b71fc5973023079713d7300757" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089158/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089158", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7060-a738-82d6a97e8a06" } rHQ5iIy69WjcA4aq3lVb+OeaibJF//Euhfk4BG0voWPTF8ea+a6LeGSu64Cv10DCPaecG5K0DPA7tzNV90GPDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: rHQ5iIy69WjcA4aq3lVb+OeaibJF//Euhfk4BG0voWPTF8ea+a6LeGSu64Cv10DCPaecG5K0DPA7tzNV90GPDQ== {"files":[{"bytes":18312,"name":"index.html","sha256":"0fcdc71882e2806b9c264003d767901abad74f094f831ae7c4c95761b5c53cda"},{"bytes":7962,"name":"publication.md","sha256":"5e68231b4588133a79886ab78f54d5ed1dc380c7f7cddb422a63d40fa6d87dcb"},{"bytes":7608,"name":"publication.txt","sha256":"b480f1d94fa58a30a16a532273fcd1fc6e1a15a4a115f8304cb6b489183f64b7"},{"bytes":2907,"name":"manifest.json","sha256":"a7a16c0d8339226f9aff1bdcd275f542fbd01ab84665af870dfdb900a4ec320c"},{"bytes":89,"name":"manifest.sig","sha256":"13e61c6199be5d53062340754441b901662bc89f1be87b263c4b692be32c5e5a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"197b8132a5ba566bcef8224e18c06718e669bc16be40a7f2c3ee3d5d61f713ef"}],"publication_id":"OT-2026-000089159"} Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089159
OpenTechnical

OT-2026-000089159

Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
b480f1d94fa58a30a16a532273fcd1fc6e1a15a4a115f8304cb6b489183f64b7

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089159, “Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089159.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089159" title: "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089159" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089159 Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089159 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089159 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089159 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089159", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1084 }, "figures": [], "files": [ { "bytes": 18312, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0fcdc71882e2806b9c264003d767901abad74f094f831ae7c4c95761b5c53cda" }, { "bytes": 7962, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5e68231b4588133a79886ab78f54d5ed1dc380c7f7cddb422a63d40fa6d87dcb" }, { "bytes": 7608, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b480f1d94fa58a30a16a532273fcd1fc6e1a15a4a115f8304cb6b489183f64b7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089159/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089159", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-724e-920c-b2e79852b329" } V2hk0IaZBQyVfMitmOSAa5X4DVxkVxSiIpLkKJfug2bTbF+kK8KaNqvxJMDMEqJpRpj/6q/iHO+ve7edpcbNDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: V2hk0IaZBQyVfMitmOSAa5X4DVxkVxSiIpLkKJfug2bTbF+kK8KaNqvxJMDMEqJpRpj/6q/iHO+ve7edpcbNDA== {"files":[{"bytes":19118,"name":"index.html","sha256":"b8a9970702c9806226c770f863a8a8f4e59b530c450469f19f4a938309d20ea3"},{"bytes":8650,"name":"publication.md","sha256":"f87c02d2331659eb8d1b73a5350eb258642e229c3fed6aa7359134c996fbdd0e"},{"bytes":8297,"name":"publication.txt","sha256":"99788bf4e75dbbbc9f20086c371b89e1b4978015def84bfcf73a0a4633de220c"},{"bytes":2912,"name":"manifest.json","sha256":"fd0b4273d443174157c6284b214cc184d283774d04ee1cc490d9017883d7520b"},{"bytes":89,"name":"manifest.sig","sha256":"ff055899d6bbcb47383d4dec3cf0091c2ce358312e023da495f0b10977aada77"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0163cb38106ec22da7bcb650a8854399e93f8a89ada3fa806dee4372996f0b3c"}],"publication_id":"OT-2026-000089160"} Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089160
OpenTechnical

OT-2026-000089160

Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
99788bf4e75dbbbc9f20086c371b89e1b4978015def84bfcf73a0a4633de220c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089160, “Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089160.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089160" title: "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089160" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089160 Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089160 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089160 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089160 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089160", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1190 }, "figures": [], "files": [ { "bytes": 19118, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b8a9970702c9806226c770f863a8a8f4e59b530c450469f19f4a938309d20ea3" }, { "bytes": 8650, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f87c02d2331659eb8d1b73a5350eb258642e229c3fed6aa7359134c996fbdd0e" }, { "bytes": 8297, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "99788bf4e75dbbbc9f20086c371b89e1b4978015def84bfcf73a0a4633de220c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089160/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089160", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7964-ad29-399efc14c125" } GV+8YtmQidDnomsGETQ8F0Tybup5TWAW/Yosy9IIqfShx0o+ea15PczUvfM1ILP9KeKT1aM+wawmh8by2++JDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: GV+8YtmQidDnomsGETQ8F0Tybup5TWAW/Yosy9IIqfShx0o+ea15PczUvfM1ILP9KeKT1aM+wawmh8by2++JDg== {"files":[{"bytes":18865,"name":"index.html","sha256":"883d6acf3a2639540ddc347da925281c719bde580091276791381ee4353a7ac7"},{"bytes":8440,"name":"publication.md","sha256":"2c1ffae627eccbd757389228d4fe8ce8af7e88ce3e77dce7686bf5a058ff6bb4"},{"bytes":8087,"name":"publication.txt","sha256":"22d2df1d9a5ec26c1d0e51b852bedd39d1262a332f4906cc06c123ea91052974"},{"bytes":2912,"name":"manifest.json","sha256":"a6b86b4f223d7d72b9251d20c36bfd7f9d5e20c42b6b28daeb2f053c23d92f41"},{"bytes":89,"name":"manifest.sig","sha256":"d6056d40ef48e2feab3df881f5f205cbdcc126e5e2942b28ef3115eeba5ae43b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"835b249a79278356ace5189f6b4e48b9b1a59368d58f687ab08efb27a605393b"}],"publication_id":"OT-2026-000089161"} Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089161
OpenTechnical

OT-2026-000089161

Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
22d2df1d9a5ec26c1d0e51b852bedd39d1262a332f4906cc06c123ea91052974

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089161, “Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089161.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089161" title: "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089161" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089161 Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089161 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089161 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089161 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089161", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1155 }, "figures": [], "files": [ { "bytes": 18865, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "883d6acf3a2639540ddc347da925281c719bde580091276791381ee4353a7ac7" }, { "bytes": 8440, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "2c1ffae627eccbd757389228d4fe8ce8af7e88ce3e77dce7686bf5a058ff6bb4" }, { "bytes": 8087, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "22d2df1d9a5ec26c1d0e51b852bedd39d1262a332f4906cc06c123ea91052974" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089161/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089161", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7e05-b973-678cd2b56512" } mfucwkNkl9cdOy7Z6hG93kS5yikkbenzvjrwaGDj4RyU3+sh/wHRNWPyGN5ffc5xQBgf9PVzc74h6zGjTVg1Dg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: mfucwkNkl9cdOy7Z6hG93kS5yikkbenzvjrwaGDj4RyU3+sh/wHRNWPyGN5ffc5xQBgf9PVzc74h6zGjTVg1Dg== {"files":[{"bytes":18312,"name":"index.html","sha256":"8a9e128053cea005b695ed29c09e05128e9eff2e00e4bc5bbcd8f55dee890692"},{"bytes":7962,"name":"publication.md","sha256":"9649bc6dadc3473ae87aa9ad1596e1799c0983af7fb4bee335d4310f4866d395"},{"bytes":7608,"name":"publication.txt","sha256":"91001cbf40e9281627a6c29085f869b3846074f7c9709766c0cc54c078def063"},{"bytes":2907,"name":"manifest.json","sha256":"25bbb7ce53a47b514113063c913f4e425d556d55e0aa297f83550ba16b2152d7"},{"bytes":89,"name":"manifest.sig","sha256":"fef9794c1873da31d8865943667a9ab28fd400d5070affcaeddd8d4e1aaa145c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"cb34031ca4a1d528ef731ac62127678782f4c2edd76e2543bb2f272cefa536b1"}],"publication_id":"OT-2026-000089162"} Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089162
OpenTechnical

OT-2026-000089162

Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
91001cbf40e9281627a6c29085f869b3846074f7c9709766c0cc54c078def063

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089162, “Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089162.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089162" title: "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089162" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089162 Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089162 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089162 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089162 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089162", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1084 }, "figures": [], "files": [ { "bytes": 18312, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8a9e128053cea005b695ed29c09e05128e9eff2e00e4bc5bbcd8f55dee890692" }, { "bytes": 7962, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9649bc6dadc3473ae87aa9ad1596e1799c0983af7fb4bee335d4310f4866d395" }, { "bytes": 7608, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "91001cbf40e9281627a6c29085f869b3846074f7c9709766c0cc54c078def063" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089162/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089162", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7450-afef-99d4df08667f" } pvMqu9XjUz6OsxXmusY63C1jzG9rrT9PIPxMowxJ2pRTI9HBvP0QCY7NU9RkFpMRLGw0m96fYYFAg5oc4/7cDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: pvMqu9XjUz6OsxXmusY63C1jzG9rrT9PIPxMowxJ2pRTI9HBvP0QCY7NU9RkFpMRLGw0m96fYYFAg5oc4/7cDg== {"files":[{"bytes":19118,"name":"index.html","sha256":"7b369adc958302b5df5fe2bd84a5a8e2b12176b808e9a47a70f582e27e9fcf5a"},{"bytes":8650,"name":"publication.md","sha256":"ecda8d32d7a2c782c0b1a225ef45cdd026d5ef98dd6a2b76ec55b5ce931f832c"},{"bytes":8297,"name":"publication.txt","sha256":"cd7a8c1f3671768b742cca44574072447b1942dce8a78d31267f5c33c5242532"},{"bytes":2912,"name":"manifest.json","sha256":"d11e68d95cd437f3fb7e43d2454f252778363333d4c762d57dd8ed60870fe1f8"},{"bytes":89,"name":"manifest.sig","sha256":"3a69f259fb47947e7effa243165be37a166b8a767c072e81f06cc9c3f8b2708f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ae4f562438ea16387361469a0e1c569cab4ae640e4f9d02f35dfc2557107ca19"}],"publication_id":"OT-2026-000089163"} Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089163
OpenTechnical

OT-2026-000089163

Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cd7a8c1f3671768b742cca44574072447b1942dce8a78d31267f5c33c5242532

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089163, “Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089163.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089163" title: "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089163" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089163 Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089163 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089163 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089163 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089163", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1190 }, "figures": [], "files": [ { "bytes": 19118, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7b369adc958302b5df5fe2bd84a5a8e2b12176b808e9a47a70f582e27e9fcf5a" }, { "bytes": 8650, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ecda8d32d7a2c782c0b1a225ef45cdd026d5ef98dd6a2b76ec55b5ce931f832c" }, { "bytes": 8297, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cd7a8c1f3671768b742cca44574072447b1942dce8a78d31267f5c33c5242532" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089163/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089163", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-743f-9884-9256078be07d" } 5CpygOb2e8AQESa4ShgcQh9o2R6eIeKX0V5lV/0hEz8cnC/HGBRrcISAMI2OMXI6lfl8jsWg5Bt78BSetUcdCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 5CpygOb2e8AQESa4ShgcQh9o2R6eIeKX0V5lV/0hEz8cnC/HGBRrcISAMI2OMXI6lfl8jsWg5Bt78BSetUcdCQ== {"files":[{"bytes":18865,"name":"index.html","sha256":"6bba830cb9d04b318e745ae4b49ec985fb3cacdbbf3546898b682d901f20953b"},{"bytes":8440,"name":"publication.md","sha256":"e7e889522ed6e95c923ad5b945b183857de70a715d40ef074510c9006a40bd11"},{"bytes":8087,"name":"publication.txt","sha256":"418f28fbd9b5335576caf122a4941b26b5a294edc2f86a5f8e06448da6987438"},{"bytes":2912,"name":"manifest.json","sha256":"bd3d74bc1c96bc1715c1e2fae5e32e59c0fa0f6ecc805fb6da1711621eb78d44"},{"bytes":89,"name":"manifest.sig","sha256":"b0494c8559ec3b6444de4fd09aa547835c4d58a567ad1b40288f7900425c8360"},{"bytes":227,"name":"manifest.sig.txt","sha256":"aff7d1bd244a3bb9274f5dbeafeb0546d532725c706f006cd5f6caf84078a019"}],"publication_id":"OT-2026-000089164"} Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089164
OpenTechnical

OT-2026-000089164

Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
418f28fbd9b5335576caf122a4941b26b5a294edc2f86a5f8e06448da6987438

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining three manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089164, “Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089164.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089164" title: "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089164" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089164 Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089164 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining three manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089164 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089164 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one plant vacuum connection, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089164", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1155 }, "figures": [], "files": [ { "bytes": 18865, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6bba830cb9d04b318e745ae4b49ec985fb3cacdbbf3546898b682d901f20953b" }, { "bytes": 8440, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e7e889522ed6e95c923ad5b945b183857de70a715d40ef074510c9006a40bd11" }, { "bytes": 8087, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "418f28fbd9b5335576caf122a4941b26b5a294edc2f86a5f8e06448da6987438" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089164/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089164", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-786e-98cd-670032663271" } B+2uB3nV7DcgjFfYtylDNyQUaSdWtmarrfIIuC53Tpz60paKjL2nkhw7q8ltPY+soOFq16jVctaccUnwbNxTBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: B+2uB3nV7DcgjFfYtylDNyQUaSdWtmarrfIIuC53Tpz60paKjL2nkhw7q8ltPY+soOFq16jVctaccUnwbNxTBA== {"files":[{"bytes":18359,"name":"index.html","sha256":"28e2cf0f392acea0384c9cf63e53233567c505f088d2fd7450d5537faebb4c9b"},{"bytes":7950,"name":"publication.md","sha256":"d18dc9f599c9eebe86e340622495dc2f220f2c1a4823a9e3f904928acce7b9ca"},{"bytes":7615,"name":"publication.txt","sha256":"a0c84ba7e25cab2af355ba6973972b2f53bc8c67534ee9a1f38c948516b78c88"},{"bytes":2864,"name":"manifest.json","sha256":"f5f5605addc7d65e4da578c722d13b786aa261a6a1152795f59b80e72256d864"},{"bytes":89,"name":"manifest.sig","sha256":"eae3519aacd2ede1db46b2f328c5f3fed12cf9320b3bbbe44d029b1eadba87e8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"355b3e66f3bfd7ef4f79576b25fc706b9d03a5b215d9ba6b69633a17e81c3987"}],"publication_id":"OT-2026-000089165"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089165
OpenTechnical

OT-2026-000089165

Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
a0c84ba7e25cab2af355ba6973972b2f53bc8c67534ee9a1f38c948516b78c88

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089165, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089165.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089165" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089165" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089165 Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089165 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089165 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089165 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089165", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1094 }, "figures": [], "files": [ { "bytes": 18359, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "28e2cf0f392acea0384c9cf63e53233567c505f088d2fd7450d5537faebb4c9b" }, { "bytes": 7950, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d18dc9f599c9eebe86e340622495dc2f220f2c1a4823a9e3f904928acce7b9ca" }, { "bytes": 7615, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a0c84ba7e25cab2af355ba6973972b2f53bc8c67534ee9a1f38c948516b78c88" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089165/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089165", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7c81-b43d-7702d2df3946" } eIja6UCtTrHcNx2mffVfB/LAYcO0NrvzHPBoSHw+Cd2bH0VgkUvGfYp90c2Dor68JjvaYHy+fbrLWoQOH15LAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: eIja6UCtTrHcNx2mffVfB/LAYcO0NrvzHPBoSHw+Cd2bH0VgkUvGfYp90c2Dor68JjvaYHy+fbrLWoQOH15LAA== {"files":[{"bytes":19174,"name":"index.html","sha256":"cd5609672a49b9002656e5695462e2fdbb7b4eb6fb67f2c86325bfbde0881e99"},{"bytes":8651,"name":"publication.md","sha256":"42c9046b1f3f8bd1818cfc05d40f185715fff2ea281d4c49f8d208410e70266d"},{"bytes":8310,"name":"publication.txt","sha256":"7908b8c12eed1ff74ef23f35765b762010d4b576dc5ca14d41aeaf1d2a3c1022"},{"bytes":2876,"name":"manifest.json","sha256":"6501047b978c3cb5bce6ed4159c633b8689c768fc43f34882333e64d73309190"},{"bytes":89,"name":"manifest.sig","sha256":"9160f523caa4b46cefca7cdbca64bd79c3afc4a0040db4a24c71a46ea06dff37"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e311884dd006a12d2674c69f2096d15ef7c52e9004333c46a6d98313d0b56b8c"}],"publication_id":"OT-2026-000089166"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089166
OpenTechnical

OT-2026-000089166

Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7908b8c12eed1ff74ef23f35765b762010d4b576dc5ca14d41aeaf1d2a3c1022

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089166, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089166.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089166" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089166" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089166 Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089166 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089166 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089166 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089166", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1200 }, "figures": [], "files": [ { "bytes": 19174, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "cd5609672a49b9002656e5695462e2fdbb7b4eb6fb67f2c86325bfbde0881e99" }, { "bytes": 8651, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "42c9046b1f3f8bd1818cfc05d40f185715fff2ea281d4c49f8d208410e70266d" }, { "bytes": 8310, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7908b8c12eed1ff74ef23f35765b762010d4b576dc5ca14d41aeaf1d2a3c1022" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089166/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089166", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7b23-b16e-3ac57787c976" } 6PwV6C6GTSFd1W63Ndg4BoLqd0hU2qEFQLUORN2zKZtUqtOEg4jcRZ+RkPJCdBycXEmkuz9MIYiD3x/HQVK1AA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 6PwV6C6GTSFd1W63Ndg4BoLqd0hU2qEFQLUORN2zKZtUqtOEg4jcRZ+RkPJCdBycXEmkuz9MIYiD3x/HQVK1AA== {"files":[{"bytes":18921,"name":"index.html","sha256":"182ce11e2bf675051fdc82ce3a5641c8efbc83b7464975f0c31366d2f4cf2af9"},{"bytes":8441,"name":"publication.md","sha256":"390907ffaa3348bf1cc7928f5dfa7f54f73636aa7195d31f7e0f3c9931a4142c"},{"bytes":8100,"name":"publication.txt","sha256":"cffe04e09db1b38e5eff32c19f2d3caa401adf71bfa1f99228a545b11f8584e2"},{"bytes":2876,"name":"manifest.json","sha256":"519eab362e86a6c9ba171612cf4515fe7783c985ead4511fc8eee611546a2828"},{"bytes":89,"name":"manifest.sig","sha256":"b501a97c4e85f24fe1020edca04f99f892088b6882efe6cb5dd3a2f182be6420"},{"bytes":227,"name":"manifest.sig.txt","sha256":"43fcb83e3c3a481b1bba56cf4e9dd7ec08f9b846deb2b9cc16b010070864d732"}],"publication_id":"OT-2026-000089167"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089167
OpenTechnical

OT-2026-000089167

Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cffe04e09db1b38e5eff32c19f2d3caa401adf71bfa1f99228a545b11f8584e2

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089167, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089167.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089167" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089167" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089167 Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089167 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089167 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089167 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089167", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1165 }, "figures": [], "files": [ { "bytes": 18921, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "182ce11e2bf675051fdc82ce3a5641c8efbc83b7464975f0c31366d2f4cf2af9" }, { "bytes": 8441, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "390907ffaa3348bf1cc7928f5dfa7f54f73636aa7195d31f7e0f3c9931a4142c" }, { "bytes": 8100, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cffe04e09db1b38e5eff32c19f2d3caa401adf71bfa1f99228a545b11f8584e2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089167/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089167", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7cb5-924f-7cb2c5b9efd9" } GH4bZMS50QGYyYATdxRl2+DV1qDJp0aN8ISL+5tT6BnfqM1ej4Itry3WVwYxUr0ZMwGTNSpoO7dbOReVgbPqBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: GH4bZMS50QGYyYATdxRl2+DV1qDJp0aN8ISL+5tT6BnfqM1ej4Itry3WVwYxUr0ZMwGTNSpoO7dbOReVgbPqBQ== {"files":[{"bytes":18360,"name":"index.html","sha256":"8ced1169034bbaa72f8f085df8ab32072b141d76bf61fa8e53c7c449c622fc48"},{"bytes":7951,"name":"publication.md","sha256":"dd0b6d509aff97e2f61ffde930945cd991a6d88715c629b32ae82ef84d5f7de9"},{"bytes":7616,"name":"publication.txt","sha256":"7d11c3c751678a780215e14414ca7048cdc65e3031015632119589ec0896e682"},{"bytes":2864,"name":"manifest.json","sha256":"b2e3c1bab61cdcaea0bbe21afad70f4693b28d00479176c447a5df6e1be48118"},{"bytes":89,"name":"manifest.sig","sha256":"0038752fd2eaae734f353f359ba17e06b9a888b23e126c00bbac7b073fbebd8b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"31bc79fafcecc38d6d6af96a24d14e7a7c450bcff22eafc689f7752c5fb4bccf"}],"publication_id":"OT-2026-000089168"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089168
OpenTechnical

OT-2026-000089168

Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
7d11c3c751678a780215e14414ca7048cdc65e3031015632119589ec0896e682

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089168, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089168.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089168" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089168" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089168 Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089168 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089168 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089168 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089168", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1094 }, "figures": [], "files": [ { "bytes": 18360, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8ced1169034bbaa72f8f085df8ab32072b141d76bf61fa8e53c7c449c622fc48" }, { "bytes": 7951, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "dd0b6d509aff97e2f61ffde930945cd991a6d88715c629b32ae82ef84d5f7de9" }, { "bytes": 7616, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7d11c3c751678a780215e14414ca7048cdc65e3031015632119589ec0896e682" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089168/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089168", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-748d-898d-dffeb2adbb89" } QJHYg5nHI6e0vC3AZKtxnsQKNPdVIabh+MRXuAH6s79EQk2YFiadDlLAIAnVUjyxFnglXX5aShXMD39pn/0jAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: QJHYg5nHI6e0vC3AZKtxnsQKNPdVIabh+MRXuAH6s79EQk2YFiadDlLAIAnVUjyxFnglXX5aShXMD39pn/0jAA== {"files":[{"bytes":19175,"name":"index.html","sha256":"7a312cf3c01b4ef5b978ae1f7235f23a91f73c8f638fc5d52173bc9812510690"},{"bytes":8652,"name":"publication.md","sha256":"bddb5017e743694fb46028dfe4c3293a2d5e8517b22f443ccc7c6cc3e740cc9f"},{"bytes":8311,"name":"publication.txt","sha256":"b8d2585f39ab1204d9ce4f6198c218c598dab0529873deb251dcd812e591ea00"},{"bytes":2876,"name":"manifest.json","sha256":"f714aa64bce2cfd417358985299225ceee262a15771211580bb0317bb2b6824b"},{"bytes":89,"name":"manifest.sig","sha256":"099497642de10b91a185eae24862aa7fd5486b91d0527b65c22a62d865ae1419"},{"bytes":227,"name":"manifest.sig.txt","sha256":"cff47e285705b52e39715c3ef084906bb657784e3a84e44d05fae5d1acc3b2de"}],"publication_id":"OT-2026-000089169"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089169
OpenTechnical

OT-2026-000089169

Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
b8d2585f39ab1204d9ce4f6198c218c598dab0529873deb251dcd812e591ea00

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089169, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089169.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089169" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089169" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089169 Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089169 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089169 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089169 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089169", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1200 }, "figures": [], "files": [ { "bytes": 19175, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7a312cf3c01b4ef5b978ae1f7235f23a91f73c8f638fc5d52173bc9812510690" }, { "bytes": 8652, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "bddb5017e743694fb46028dfe4c3293a2d5e8517b22f443ccc7c6cc3e740cc9f" }, { "bytes": 8311, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b8d2585f39ab1204d9ce4f6198c218c598dab0529873deb251dcd812e591ea00" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089169/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089169", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7608-8c1f-ca7ee36fd2d2" } AFSZZ8ereCIDy/S7mpSwg5UXxAICqujC/A5hfr7BLyVLU+hta/Q8ibNriOB+7cJDmH8UkEu2JZ6uJZqxrh1lBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: AFSZZ8ereCIDy/S7mpSwg5UXxAICqujC/A5hfr7BLyVLU+hta/Q8ibNriOB+7cJDmH8UkEu2JZ6uJZqxrh1lBg== {"files":[{"bytes":18922,"name":"index.html","sha256":"d8b295042054493fbf688ed72f3499a7ac42b4d555f9bdbdfe66a8df8d9595f3"},{"bytes":8442,"name":"publication.md","sha256":"571a9cbf5989a30e3f7dffba1da56ec7f4e8161b9bda4211151e8c9244ae022a"},{"bytes":8101,"name":"publication.txt","sha256":"2f214f346fbdaf9162b87ee9f6e61b3683b8e40c12825a8785a20359f84a8db2"},{"bytes":2876,"name":"manifest.json","sha256":"f4a0da37f27e856b098d838c49039959c394051232d1c889c59e0f40e3b0e766"},{"bytes":89,"name":"manifest.sig","sha256":"70458095b164032751b446d6f664048c387c7256f14cf6f839a47bcca88c26c2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7fefa60dac46862b2e389b338afee6ee9b0e6f934c5dac0ad92b5a6dce0376ad"}],"publication_id":"OT-2026-000089170"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089170
OpenTechnical

OT-2026-000089170

Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
2f214f346fbdaf9162b87ee9f6e61b3683b8e40c12825a8785a20359f84a8db2

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089170, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089170.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089170" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089170" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089170 Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089170 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089170 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089170 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089170", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1165 }, "figures": [], "files": [ { "bytes": 18922, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d8b295042054493fbf688ed72f3499a7ac42b4d555f9bdbdfe66a8df8d9595f3" }, { "bytes": 8442, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "571a9cbf5989a30e3f7dffba1da56ec7f4e8161b9bda4211151e8c9244ae022a" }, { "bytes": 8101, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2f214f346fbdaf9162b87ee9f6e61b3683b8e40c12825a8785a20359f84a8db2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089170/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089170", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7c54-a6bb-a0d699adb2bb" } 3XuImgvUTKJGJmNg5XJC9zoqXpBigaeZULr1QbIIbeZMsKnKKQx1Bz5vBCrYK7/daITTIUuOcp2N3B8KtBJqDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 3XuImgvUTKJGJmNg5XJC9zoqXpBigaeZULr1QbIIbeZMsKnKKQx1Bz5vBCrYK7/daITTIUuOcp2N3B8KtBJqDg== {"files":[{"bytes":18364,"name":"index.html","sha256":"04cbeb3466df8a9fc0f3ec46df8cc9800100a6c5c158f93e7ad62a2116dcddae"},{"bytes":7955,"name":"publication.md","sha256":"6339ae191fce7557ed44f7cbee047608602439535e9e57097bd543986683eb93"},{"bytes":7620,"name":"publication.txt","sha256":"d877453c8811724ef4348f47909ff7a8f385998b8eaf1cc4578f4dc2027bd08c"},{"bytes":2864,"name":"manifest.json","sha256":"37bfe2d2afe811e08438bb5d10ffb9c060bc5fbbf6b81755c1d54a8b5810309f"},{"bytes":89,"name":"manifest.sig","sha256":"b1f5b4d67b865bbf0a0057712c3bbf784135ef16179d954bf3e4d4b77ee3044a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"68eddc3701ad6ca61a89f4f25926cd73afdea85a8c8f7aaaea2bd6d3479a766f"}],"publication_id":"OT-2026-000089171"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089171
OpenTechnical

OT-2026-000089171

Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
d877453c8811724ef4348f47909ff7a8f385998b8eaf1cc4578f4dc2027bd08c

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089171, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089171.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089171" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089171" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089171 Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089171 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089171 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089171 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089171", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1094 }, "figures": [], "files": [ { "bytes": 18364, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "04cbeb3466df8a9fc0f3ec46df8cc9800100a6c5c158f93e7ad62a2116dcddae" }, { "bytes": 7955, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "6339ae191fce7557ed44f7cbee047608602439535e9e57097bd543986683eb93" }, { "bytes": 7620, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d877453c8811724ef4348f47909ff7a8f385998b8eaf1cc4578f4dc2027bd08c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089171/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089171", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7f64-ba79-4156fc74f10a" } FnYfCFJVk6kE//itDqCnqi0ycLDGIvA0scy3ZcuJx0Wmqm5lu1YJ2huKiG8V8IkEysFZhSRbnA4Jj7LGoqtxAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: FnYfCFJVk6kE//itDqCnqi0ycLDGIvA0scy3ZcuJx0Wmqm5lu1YJ2huKiG8V8IkEysFZhSRbnA4Jj7LGoqtxAw== {"files":[{"bytes":19179,"name":"index.html","sha256":"b337387477734ac8d58679a358ef30640cde7162a13cc9f91bda272267659304"},{"bytes":8656,"name":"publication.md","sha256":"96af7e2c00b723a6db4836adc623fc56bd3310f6656da1308287667ff3655b58"},{"bytes":8315,"name":"publication.txt","sha256":"f4b0be0bc5384e9a3ec3d8a3e4d50c369f7f064c09209691bbff12276f90b929"},{"bytes":2876,"name":"manifest.json","sha256":"8ef577796b51ac14830c0a5359e389c6ed127b3f0c9598644012d56e354526f1"},{"bytes":89,"name":"manifest.sig","sha256":"0a0c96fb60fa9d74fbb9a32ea624b5919da7cb17cf26021ce24229dea511e5ca"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1188e10b2ea4005b70d5daf4be14709fe4e961ecba4570b2caaecc8dd0e8ddb2"}],"publication_id":"OT-2026-000089172"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089172
OpenTechnical

OT-2026-000089172

Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f4b0be0bc5384e9a3ec3d8a3e4d50c369f7f064c09209691bbff12276f90b929

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089172, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089172.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089172" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089172" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089172 Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089172 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089172 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089172 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089172", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1200 }, "figures": [], "files": [ { "bytes": 19179, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b337387477734ac8d58679a358ef30640cde7162a13cc9f91bda272267659304" }, { "bytes": 8656, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "96af7e2c00b723a6db4836adc623fc56bd3310f6656da1308287667ff3655b58" }, { "bytes": 8315, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f4b0be0bc5384e9a3ec3d8a3e4d50c369f7f064c09209691bbff12276f90b929" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089172/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089172", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7f55-bd49-ae0cdbeb0a81" } vEmsQBabtC7En6B00MpGq4Jit6wJJ3VHeB8Qctw4vaSyxUqKjF3jmRFcxYWDikWwFvwxH979qOynvsfHugkhCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: vEmsQBabtC7En6B00MpGq4Jit6wJJ3VHeB8Qctw4vaSyxUqKjF3jmRFcxYWDikWwFvwxH979qOynvsfHugkhCg== {"files":[{"bytes":18926,"name":"index.html","sha256":"316485cab6a470f461c106b7e82861fe3741d01fbddfb06270ecc3d0e3f42ea3"},{"bytes":8446,"name":"publication.md","sha256":"4c9b774e8335fee8a8f7146d7d05b24e68204eff0d45fb8898abd1fafea0a20d"},{"bytes":8105,"name":"publication.txt","sha256":"1cf0d328b5dbde24a82b662018c8ccdf88d89e6583c5403406ab074e42373af4"},{"bytes":2876,"name":"manifest.json","sha256":"fa3f7f56a7f09e3ed1e684b507c4ce34149b9d1d107cad1d4301d48bfa5774c2"},{"bytes":89,"name":"manifest.sig","sha256":"0c049f2468acd32c2606ddb52cc8726082164de8f505201e14b6e6b368cadbfe"},{"bytes":227,"name":"manifest.sig.txt","sha256":"50e5ff56d01ab3467e2444a6ae9ebeb4e76e34dac5fc89227ec9637a1739cc4c"}],"publication_id":"OT-2026-000089173"} Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089173
OpenTechnical

OT-2026-000089173

Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
1cf0d328b5dbde24a82b662018c8ccdf88d89e6583c5403406ab074e42373af4

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089173, “Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089173.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089173" title: "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089173" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089173 Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089173 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089173 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089173 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089173", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1165 }, "figures": [], "files": [ { "bytes": 18926, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "316485cab6a470f461c106b7e82861fe3741d01fbddfb06270ecc3d0e3f42ea3" }, { "bytes": 8446, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4c9b774e8335fee8a8f7146d7d05b24e68204eff0d45fb8898abd1fafea0a20d" }, { "bytes": 8105, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1cf0d328b5dbde24a82b662018c8ccdf88d89e6583c5403406ab074e42373af4" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089173/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089173", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7870-80bf-5d49f279f265" } z4/IHuCxQ6efIgCBFVEsKZkBiZZTyFegKh5C2htgWn+fK0lz++dfJeIe24lI1eIkExYBpQG4bZQTUa8+MeXzBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: z4/IHuCxQ6efIgCBFVEsKZkBiZZTyFegKh5C2htgWn+fK0lz++dfJeIe24lI1eIkExYBpQG4bZQTUa8+MeXzBA== {"files":[{"bytes":18537,"name":"index.html","sha256":"d92473bd44352f5ce6518a16e0790c3f3d5dc9ebdbfa7e29b2c8500a1c49e59f"},{"bytes":8100,"name":"publication.md","sha256":"e11e68444c8a6e3d553610a65d4383996cec13e33670c6603cd699db877572c8"},{"bytes":7777,"name":"publication.txt","sha256":"96bd881be638502d3602197dcb6d6d4403a9d7a784e4e56531e2e90832d0081c"},{"bytes":2839,"name":"manifest.json","sha256":"594984b6e4f14efd399c50f7f30e369e770d3001491e702f158a5c3ef43d7b7d"},{"bytes":89,"name":"manifest.sig","sha256":"c1704f677be328907a219172ee9e642953668e1a45cf635d23b4a2e6564aed78"},{"bytes":227,"name":"manifest.sig.txt","sha256":"06634fe812520b1a4efb0f01d33eb51ac35ff594808e60fef15dfbda6f25e549"}],"publication_id":"OT-2026-000089174"} Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089174
OpenTechnical

OT-2026-000089174

Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
96bd881be638502d3602197dcb6d6d4403a9d7a784e4e56531e2e90832d0081c

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089174, “Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089174.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089174" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089174" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089174 Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089174 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089174 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089174 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089174", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1134 }, "figures": [], "files": [ { "bytes": 18537, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d92473bd44352f5ce6518a16e0790c3f3d5dc9ebdbfa7e29b2c8500a1c49e59f" }, { "bytes": 8100, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e11e68444c8a6e3d553610a65d4383996cec13e33670c6603cd699db877572c8" }, { "bytes": 7777, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "96bd881be638502d3602197dcb6d6d4403a9d7a784e4e56531e2e90832d0081c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089174/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089174", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7fee-a40b-b9d711eb2a3a" } OFH5pNEo/NqM8G7JHysYXAw9o1A73xNcV0MBpeQTIAe9zJ/yxj+eHKZugbMbMgIIUF9auWTYdB5bc3fm/jFwAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: OFH5pNEo/NqM8G7JHysYXAw9o1A73xNcV0MBpeQTIAe9zJ/yxj+eHKZugbMbMgIIUF9auWTYdB5bc3fm/jFwAQ== {"files":[{"bytes":19352,"name":"index.html","sha256":"f39883379c98e1c9f9f0228ba4125d49624785912ca867d42dfdf7a753478298"},{"bytes":8801,"name":"publication.md","sha256":"027f003511897a487df12a25bca75364c286549c669e59278e8b68400cd081a8"},{"bytes":8472,"name":"publication.txt","sha256":"fe0e90002fa7519e082c2996ab091cde7ea83057e08dc6b09ac9ce7825246362"},{"bytes":2851,"name":"manifest.json","sha256":"8c7ec6d16c0f2d844dc631d5db6f4707260e4b9251642048c41309e53ae9a5f7"},{"bytes":89,"name":"manifest.sig","sha256":"4246d3e0a2e685feb5101f6ed0eefeb37f59c21614405ce4aac04c592319103e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"701edb8d1b43c8b9b02f1c893a38ccc306f645a721f54651b2ec83e3ec1e8197"}],"publication_id":"OT-2026-000089175"} Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089175
OpenTechnical

OT-2026-000089175

Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
fe0e90002fa7519e082c2996ab091cde7ea83057e08dc6b09ac9ce7825246362

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089175, “Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089175.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089175" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089175" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089175 Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089175 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089175 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089175 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089175", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1240 }, "figures": [], "files": [ { "bytes": 19352, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f39883379c98e1c9f9f0228ba4125d49624785912ca867d42dfdf7a753478298" }, { "bytes": 8801, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "027f003511897a487df12a25bca75364c286549c669e59278e8b68400cd081a8" }, { "bytes": 8472, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fe0e90002fa7519e082c2996ab091cde7ea83057e08dc6b09ac9ce7825246362" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089175/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089175", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-78b4-8ef8-063576e2ec00" } 3Y4KHIHHmNdAYAUv+2v5cpB6cOuMrK/z92Sf3SgQeEWDV8MAXh10ZIoQnHVP6dyR85dnSKbSh5PdhX1W0dcQBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 3Y4KHIHHmNdAYAUv+2v5cpB6cOuMrK/z92Sf3SgQeEWDV8MAXh10ZIoQnHVP6dyR85dnSKbSh5PdhX1W0dcQBQ== {"files":[{"bytes":19099,"name":"index.html","sha256":"e860dabb85b381e5968f6263508982688a595a2b5c746e1af6b65be138f889f6"},{"bytes":8591,"name":"publication.md","sha256":"7262136333a0663bbe8a923dd5c9959cdc9da41ac85f4d7ac3cb4721a32af2b7"},{"bytes":8262,"name":"publication.txt","sha256":"c6ef888441deee51dd96a703053e0f236c497ee68945098d87e474fc09e839a8"},{"bytes":2851,"name":"manifest.json","sha256":"aa7c61eae8f64fb1295acfdec4ad32d72d4f7718bcb492efac77cec3f676e99b"},{"bytes":89,"name":"manifest.sig","sha256":"1f3f6d39e6f93e1c9cbcb0dad92ad203566068cdce4870ab6d8c76ca94d72ea6"},{"bytes":227,"name":"manifest.sig.txt","sha256":"69a5f7e3125bd82e4d3f4d23583a61fe52c7a1e3f90492e1feb9b7664274d8c0"}],"publication_id":"OT-2026-000089176"} Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089176
OpenTechnical

OT-2026-000089176

Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c6ef888441deee51dd96a703053e0f236c497ee68945098d87e474fc09e839a8

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089176, “Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089176.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089176" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089176" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089176 Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089176 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089176 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089176 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089176", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19099, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "e860dabb85b381e5968f6263508982688a595a2b5c746e1af6b65be138f889f6" }, { "bytes": 8591, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7262136333a0663bbe8a923dd5c9959cdc9da41ac85f4d7ac3cb4721a32af2b7" }, { "bytes": 8262, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c6ef888441deee51dd96a703053e0f236c497ee68945098d87e474fc09e839a8" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089176/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089176", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-78d5-8869-00dad0233fa0" } b3VDEc3I2pmb3bpHAK7YpnYpOxApkIIuo6zdKfQgj/2+Ue6uCXAa1rmDHZZ96MgcSHqWxsinhA4HZqJwxWLQAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: b3VDEc3I2pmb3bpHAK7YpnYpOxApkIIuo6zdKfQgj/2+Ue6uCXAa1rmDHZZ96MgcSHqWxsinhA4HZqJwxWLQAQ== {"files":[{"bytes":18483,"name":"index.html","sha256":"88847ee3878f07a1e52e1ed1314e5797dc68b8f95acc2054e614bf611ef4c7f4"},{"bytes":8046,"name":"publication.md","sha256":"9cbc0435ce0127fe53b477b50c351e1ef47e1c359f6071283309bfb19542122a"},{"bytes":7723,"name":"publication.txt","sha256":"50649eeac09a247023a628eabd93b097372531a14a17ca3cce7ee9420b7f68ea"},{"bytes":2839,"name":"manifest.json","sha256":"688fcc5e2a43e089f38d0d48293dd3a4620d480e23ea48393cb4fbe1df7d77ca"},{"bytes":89,"name":"manifest.sig","sha256":"561138383fa334649a67dc6a79175fda037ef1bcb9ac40bfbe89f9bbaab889fe"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7b93574ca60fae9e6e265df6795e680d373e0f84c992a2a87ad929f207fba0dc"}],"publication_id":"OT-2026-000089177"} Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089177
OpenTechnical

OT-2026-000089177

Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
50649eeac09a247023a628eabd93b097372531a14a17ca3cce7ee9420b7f68ea

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089177, “Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089177.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089177" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089177" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089177 Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089177 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089177 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089177 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089177", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1119 }, "figures": [], "files": [ { "bytes": 18483, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "88847ee3878f07a1e52e1ed1314e5797dc68b8f95acc2054e614bf611ef4c7f4" }, { "bytes": 8046, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9cbc0435ce0127fe53b477b50c351e1ef47e1c359f6071283309bfb19542122a" }, { "bytes": 7723, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "50649eeac09a247023a628eabd93b097372531a14a17ca3cce7ee9420b7f68ea" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089177/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089177", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-796d-ae2b-ac485f024799" } HQWbq2X3T8X7F7wpimHu2IRzgRukS+bl6ehoU+DlDyUulHyvGo5lj+ozD95RvYhgbTPm05kESz5Ompmd8m5HCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: HQWbq2X3T8X7F7wpimHu2IRzgRukS+bl6ehoU+DlDyUulHyvGo5lj+ozD95RvYhgbTPm05kESz5Ompmd8m5HCw== {"files":[{"bytes":19298,"name":"index.html","sha256":"13b209a2d3e30f67b7e2681cb4c9ea65e660415b21346d0a6e086f7481a77c25"},{"bytes":8747,"name":"publication.md","sha256":"eee7dfd8309b0d5912b0ddf08992a69482509264d28c7a9e690d2f5f4d2424de"},{"bytes":8418,"name":"publication.txt","sha256":"9842d79aa02e41dd798e9860d5a2504f5d6ba88528511c802d1355dbbc259c08"},{"bytes":2851,"name":"manifest.json","sha256":"6b73c875b4d54afbd0ba56a2504d786e36df818522a1c50b7579d758dc2ab0c8"},{"bytes":89,"name":"manifest.sig","sha256":"6abe2146a0e4fe9da0533875f26cb519f7831537253ad95e9f761a00584911b9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"282a710a8274c5ca6a6124e8bbd8583c1b504bb0677f354dc18f76de0daee342"}],"publication_id":"OT-2026-000089178"} Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089178
OpenTechnical

OT-2026-000089178

Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
9842d79aa02e41dd798e9860d5a2504f5d6ba88528511c802d1355dbbc259c08

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089178, “Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089178.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089178" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089178" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089178 Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089178 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089178 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089178 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089178", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1225 }, "figures": [], "files": [ { "bytes": 19298, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "13b209a2d3e30f67b7e2681cb4c9ea65e660415b21346d0a6e086f7481a77c25" }, { "bytes": 8747, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "eee7dfd8309b0d5912b0ddf08992a69482509264d28c7a9e690d2f5f4d2424de" }, { "bytes": 8418, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9842d79aa02e41dd798e9860d5a2504f5d6ba88528511c802d1355dbbc259c08" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089178/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089178", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7158-8239-9241f55e552b" } oXZOArHgWyzvgV+wwbdXrTomV3Zgn/g2CHiF2wrrstnDo1YbcgIViIamUb8/xjH4FgFtLQAYXQ60+7jvm2XdBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: oXZOArHgWyzvgV+wwbdXrTomV3Zgn/g2CHiF2wrrstnDo1YbcgIViIamUb8/xjH4FgFtLQAYXQ60+7jvm2XdBw== {"files":[{"bytes":19045,"name":"index.html","sha256":"5f898714d60e9d75e94671f79bbe33d05a4844e13e20ed53493ba91094ce5a0c"},{"bytes":8537,"name":"publication.md","sha256":"4533d081a037021a1cac0876a3118b53a6d00fbb35ae24dbc1fbcc63816e6fde"},{"bytes":8208,"name":"publication.txt","sha256":"164ee4f1cbde4846898fe237be45e87dc0993aa0b282b4f53db8df488ddeb7ff"},{"bytes":2851,"name":"manifest.json","sha256":"59774ac23756849b51c51761c9cc5e47435b77c513ed5f3a476b44ce7cb637d6"},{"bytes":89,"name":"manifest.sig","sha256":"34b24cba1bbe08e5eafc48e1e418d448261db2098abe10a3110fe5cccb57c789"},{"bytes":227,"name":"manifest.sig.txt","sha256":"fd7d3aedb254a778bdd234308733c40fd4e81dd209f638e0f094b1a28c0fb790"}],"publication_id":"OT-2026-000089179"} Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089179
OpenTechnical

OT-2026-000089179

Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
164ee4f1cbde4846898fe237be45e87dc0993aa0b282b4f53db8df488ddeb7ff

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089179, “Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089179.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089179" title: "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089179" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089179 Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089179 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089179 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089179 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089179", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1190 }, "figures": [], "files": [ { "bytes": 19045, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5f898714d60e9d75e94671f79bbe33d05a4844e13e20ed53493ba91094ce5a0c" }, { "bytes": 8537, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4533d081a037021a1cac0876a3118b53a6d00fbb35ae24dbc1fbcc63816e6fde" }, { "bytes": 8208, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "164ee4f1cbde4846898fe237be45e87dc0993aa0b282b4f53db8df488ddeb7ff" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089179/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089179", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7695-9fbe-2af0e2b66d34" } jpNZWawc7ZnlLQ3VLYjiFE4NSfUxlclqzT2jYpZ4EsQVdNoJjPV0/6JIAevtKKiHVtaZ1ToMChDrKpvSnE5XAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: jpNZWawc7ZnlLQ3VLYjiFE4NSfUxlclqzT2jYpZ4EsQVdNoJjPV0/6JIAevtKKiHVtaZ1ToMChDrKpvSnE5XAA== {"files":[{"bytes":18253,"name":"index.html","sha256":"fd5798d7a1aa2f0bb2bdd4f39ad122f8b4da2c348898c0f1d8faa35e98d4309e"},{"bytes":7860,"name":"publication.md","sha256":"63e3b18d78c3d023eb33ef74e7ebdeac43af07672b2995f95d597fdf2cb917ee"},{"bytes":7533,"name":"publication.txt","sha256":"f8e60e2a9fe144e0b040702f4f8c3566238ad0315378ce43a9e9b9f302abeb67"},{"bytes":2856,"name":"manifest.json","sha256":"391687e03c9b8982f24c7ec84a2c3f38e53c024e0e534d4028b61b3aa1a9d17d"},{"bytes":89,"name":"manifest.sig","sha256":"0b4374ab89198756df5ed63512e9751e6bec2883eba35d3eef7bc8c32add4ef8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b0236d6643d483dad152627192509e955e7704ebf7da780a8a15520792c45b5c"}],"publication_id":"OT-2026-000089180"} Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089180
OpenTechnical

OT-2026-000089180

Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
f8e60e2a9fe144e0b040702f4f8c3566238ad0315378ce43a9e9b9f302abeb67

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089180, “Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089180.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089180" title: "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089180" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089180 Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089180 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089180 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089180 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089180", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1082 }, "figures": [], "files": [ { "bytes": 18253, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "fd5798d7a1aa2f0bb2bdd4f39ad122f8b4da2c348898c0f1d8faa35e98d4309e" }, { "bytes": 7860, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "63e3b18d78c3d023eb33ef74e7ebdeac43af07672b2995f95d597fdf2cb917ee" }, { "bytes": 7533, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f8e60e2a9fe144e0b040702f4f8c3566238ad0315378ce43a9e9b9f302abeb67" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089180/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089180", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-777e-94a9-cf1537db53f5" } /nohLWlZEB+FAlowmZPaVTnPrVCbhfPK1OIKQXOYFF5NGkodoHLfwxpVHLL4Jr/dAngiGNif4Xt/GGRT2A2sCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: /nohLWlZEB+FAlowmZPaVTnPrVCbhfPK1OIKQXOYFF5NGkodoHLfwxpVHLL4Jr/dAngiGNif4Xt/GGRT2A2sCQ== {"files":[{"bytes":19068,"name":"index.html","sha256":"9709a6c1a30aed252c273e5fe35853dcd4fa4d677c775d35893f9812ce8ba125"},{"bytes":8561,"name":"publication.md","sha256":"ee7aa1e7b0da95965441b77c0badf4c338c0ec107f602a7acc8757a71b9882f8"},{"bytes":8228,"name":"publication.txt","sha256":"81e06b0eb3d4e9dc62e5dc9c436759393ad0e51a9cb4aaa79a07e4c7863d47ba"},{"bytes":2868,"name":"manifest.json","sha256":"0e086e09fd02b1699aa40a38cff16631dc469adb567c668b338a28f1daafe96c"},{"bytes":89,"name":"manifest.sig","sha256":"a7c66ef8c7aa216ce7fc5832990751335a7a590ecb9a94fafdc294e8f30a60fe"},{"bytes":227,"name":"manifest.sig.txt","sha256":"95f35715736d0c1746a9d4da086c6f5f384cb7d00663307301a6b2458ef1055e"}],"publication_id":"OT-2026-000089181"} Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089181
OpenTechnical

OT-2026-000089181

Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
81e06b0eb3d4e9dc62e5dc9c436759393ad0e51a9cb4aaa79a07e4c7863d47ba

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089181, “Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089181.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089181" title: "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089181" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089181 Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089181 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089181 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089181 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089181", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1188 }, "figures": [], "files": [ { "bytes": 19068, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9709a6c1a30aed252c273e5fe35853dcd4fa4d677c775d35893f9812ce8ba125" }, { "bytes": 8561, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ee7aa1e7b0da95965441b77c0badf4c338c0ec107f602a7acc8757a71b9882f8" }, { "bytes": 8228, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "81e06b0eb3d4e9dc62e5dc9c436759393ad0e51a9cb4aaa79a07e4c7863d47ba" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089181/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089181", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-749a-8d18-24ceb435c573" } QdHDhRRek0tr4Jl71VHHD2nFuX8YqLrnAKFQt13hZnWdjxlFrR730OATE9+ppQ6cUsOQDNqvUb9UOPcNDwsyAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: QdHDhRRek0tr4Jl71VHHD2nFuX8YqLrnAKFQt13hZnWdjxlFrR730OATE9+ppQ6cUsOQDNqvUb9UOPcNDwsyAQ== {"files":[{"bytes":18815,"name":"index.html","sha256":"d3e49cf71fce240d4027a06f03a45a7a95b1e1bae961314390f75b6e9354c2fb"},{"bytes":8351,"name":"publication.md","sha256":"f5be4d57e0ab06db88416a1376229355fa2fee7141ae6e5b043572a3e38d45f7"},{"bytes":8018,"name":"publication.txt","sha256":"7e394aedc347cfb357d7b4ff1247affd6f7c224a0af8c568bc98ca35b03a4c61"},{"bytes":2868,"name":"manifest.json","sha256":"a705f5b191a9105a84e50f6adf1f1254b29e67cb585d0f7e0bb3cccbbd22f851"},{"bytes":89,"name":"manifest.sig","sha256":"8bff6a8a439fb9a4d2e7a562131fc1490cb718c21381fad87c78ad712ab20cd8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"6a3a7d551b00ffe800a4d6f8cfc112d8bdb5d5fc713185dfd5b2a1ad8cd64977"}],"publication_id":"OT-2026-000089182"} Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089182
OpenTechnical

OT-2026-000089182

Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7e394aedc347cfb357d7b4ff1247affd6f7c224a0af8c568bc98ca35b03a4c61

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089182, “Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089182.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089182" title: "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089182" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089182 Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089182 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089182 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089182 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089182", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1153 }, "figures": [], "files": [ { "bytes": 18815, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d3e49cf71fce240d4027a06f03a45a7a95b1e1bae961314390f75b6e9354c2fb" }, { "bytes": 8351, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f5be4d57e0ab06db88416a1376229355fa2fee7141ae6e5b043572a3e38d45f7" }, { "bytes": 8018, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7e394aedc347cfb357d7b4ff1247affd6f7c224a0af8c568bc98ca35b03a4c61" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089182/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089182", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7b76-9751-1322c29c5ed1" } mbx5ADMzaK8pMzs/NPQrj+StgakMFQzfEIsHzxBJ2CEMPA8rQToz6coLJaUu0Tu/zlcdpcD+L3sBJEc7h1FlAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: mbx5ADMzaK8pMzs/NPQrj+StgakMFQzfEIsHzxBJ2CEMPA8rQToz6coLJaUu0Tu/zlcdpcD+L3sBJEc7h1FlAA== {"files":[{"bytes":18253,"name":"index.html","sha256":"713e502fe58cfdaaf008df1be01550c27fb51999bf1c589478395f8c4697bef5"},{"bytes":7860,"name":"publication.md","sha256":"b891f634789db0d971f7bcac7dd897c1ecc3c78b680ca4a0b33c5b0b5d0f64c6"},{"bytes":7533,"name":"publication.txt","sha256":"ad0bceefcb2d5d9516b23ad2f5e0847e90f76b84d7a8400ad7d689b5beb82ea0"},{"bytes":2856,"name":"manifest.json","sha256":"500fd5261a1165f8e896910796c4cf4f4bbabef5435ab265b936435714a02ffa"},{"bytes":89,"name":"manifest.sig","sha256":"97bdddf429ba06f58a1d23bbf32a7f77ac8dc192374f49c52e88ad96763afe1a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3ed148c375287d32a061208f9f49615d347c033b0e3caa8581191a6e712bc757"}],"publication_id":"OT-2026-000089183"} Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089183
OpenTechnical

OT-2026-000089183

Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
ad0bceefcb2d5d9516b23ad2f5e0847e90f76b84d7a8400ad7d689b5beb82ea0

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089183, “Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089183.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089183" title: "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089183" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089183 Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089183 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089183 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089183 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089183", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1082 }, "figures": [], "files": [ { "bytes": 18253, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "713e502fe58cfdaaf008df1be01550c27fb51999bf1c589478395f8c4697bef5" }, { "bytes": 7860, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b891f634789db0d971f7bcac7dd897c1ecc3c78b680ca4a0b33c5b0b5d0f64c6" }, { "bytes": 7533, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ad0bceefcb2d5d9516b23ad2f5e0847e90f76b84d7a8400ad7d689b5beb82ea0" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089183/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089183", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7567-a164-ea500d8bf6fc" } ALTWUclbk2aWPlTYjlU+XFL0+a4rcqRfbz6hIkK4yBbh17ot2xoP3FXGozVxNmVpFIMknUXSp6knl8Ip+smgCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ALTWUclbk2aWPlTYjlU+XFL0+a4rcqRfbz6hIkK4yBbh17ot2xoP3FXGozVxNmVpFIMknUXSp6knl8Ip+smgCQ== {"files":[{"bytes":19068,"name":"index.html","sha256":"9212bf000d48074f261af56ae9174f91aeb59fb96a531979c31fc453572a505e"},{"bytes":8561,"name":"publication.md","sha256":"e9e717a48da19f1f5abf8c3ffd14420ffe1acbd99b316424e39c3fdb674052c0"},{"bytes":8228,"name":"publication.txt","sha256":"fc69a741deb2008f99776f02fe99545cda7deb6f51268d56b12fb537cb513a4a"},{"bytes":2868,"name":"manifest.json","sha256":"bfd9bc6fd1f1a173c2b9fa2a65e6a794c6331eab0f966b3aa18e08a3f5ee95bd"},{"bytes":89,"name":"manifest.sig","sha256":"56f883386b579edc52d153e26388896029c62cd483a7428fe98832a25197bcd9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e530e371157aa4ab9e3f948acaa529bb274e530af39832ac993656a437975f91"}],"publication_id":"OT-2026-000089184"} Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089184
OpenTechnical

OT-2026-000089184

Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
fc69a741deb2008f99776f02fe99545cda7deb6f51268d56b12fb537cb513a4a

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089184, “Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089184.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089184" title: "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089184" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089184 Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089184 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089184 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089184 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089184", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1188 }, "figures": [], "files": [ { "bytes": 19068, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9212bf000d48074f261af56ae9174f91aeb59fb96a531979c31fc453572a505e" }, { "bytes": 8561, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e9e717a48da19f1f5abf8c3ffd14420ffe1acbd99b316424e39c3fdb674052c0" }, { "bytes": 8228, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fc69a741deb2008f99776f02fe99545cda7deb6f51268d56b12fb537cb513a4a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089184/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089184", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7f11-b151-594c7cb058bb" } sOFXHkmL10+XSRJQUpshij++epQH/+zxrtyqF1r5vw/8QH+FjuazLiM8ys8Ek/8oHTeH7E0/V9u9/iAhCGJ4Dg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: sOFXHkmL10+XSRJQUpshij++epQH/+zxrtyqF1r5vw/8QH+FjuazLiM8ys8Ek/8oHTeH7E0/V9u9/iAhCGJ4Dg== {"files":[{"bytes":18815,"name":"index.html","sha256":"8c4979f711ea8d36d802c2475cf1eebc93d6be19e5e60551172b045a36510909"},{"bytes":8351,"name":"publication.md","sha256":"a3088d98e9412f2d25ac1d5f3f548896245e3862fac54e4902a37460e6e80f4c"},{"bytes":8018,"name":"publication.txt","sha256":"a17a5ba3a2620e66118b96c0ff789e8f7f4f6c1b8f9c56caaa6b6673812a34e8"},{"bytes":2868,"name":"manifest.json","sha256":"bef1363d2f28d72a64ac3dde191c3867428a363e2f136c9540d0f960930eefb5"},{"bytes":89,"name":"manifest.sig","sha256":"17755a67ac684115b6ec5cb681ca120634e311af4c9ca7596526878c55284c36"},{"bytes":227,"name":"manifest.sig.txt","sha256":"df47a958e96cf2ee1a2b11d8e3b630d855a395829dea089705f3005898afc7ae"}],"publication_id":"OT-2026-000089185"} Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089185
OpenTechnical

OT-2026-000089185

Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a17a5ba3a2620e66118b96c0ff789e8f7f4f6c1b8f9c56caaa6b6673812a34e8

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining three manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089185, “Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089185.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089185" title: "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089185" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089185 Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089185 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining three manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089185 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089185 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one vacuum pump, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089185", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1153 }, "figures": [], "files": [ { "bytes": 18815, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8c4979f711ea8d36d802c2475cf1eebc93d6be19e5e60551172b045a36510909" }, { "bytes": 8351, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a3088d98e9412f2d25ac1d5f3f548896245e3862fac54e4902a37460e6e80f4c" }, { "bytes": 8018, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a17a5ba3a2620e66118b96c0ff789e8f7f4f6c1b8f9c56caaa6b6673812a34e8" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089185/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089185", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7f1d-a2db-9b1750db0b80" } W/Z++oPXGbgpI0ypqxmOMuPCx1vxMcyml4ZWhP6DPjJOGFWTfMsVsPFqproWxXwtT7BbFrYmAyH5RyKTLaTYBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: W/Z++oPXGbgpI0ypqxmOMuPCx1vxMcyml4ZWhP6DPjJOGFWTfMsVsPFqproWxXwtT7BbFrYmAyH5RyKTLaTYBg== {"files":[{"bytes":18490,"name":"index.html","sha256":"84d65ca0a33745d349fe749dced948e5b51bd76223e5e2ea0c384fbe83feaf8f"},{"bytes":8057,"name":"publication.md","sha256":"5f0f7cac60bdcaa66a39cc894c95b79c90938914006c22312c67dc3b73b30d11"},{"bytes":7716,"name":"publication.txt","sha256":"19e05fa520956b5b12a01b736a92e12eb8a430fd4b984c5fdb38fa4738453eab"},{"bytes":2860,"name":"manifest.json","sha256":"126fa5decde940f4812beb3352ea315904df340459eca8f0fcc79c133695819a"},{"bytes":89,"name":"manifest.sig","sha256":"2f8498dd1ff0ebe898a7a3f594d5279aeaf537cd2bf468ece83dc070ea931d38"},{"bytes":227,"name":"manifest.sig.txt","sha256":"290fefafaa370ca67316d12df8b73242d618da01c401f6b4d4ff57892f06465e"}],"publication_id":"OT-2026-000089186"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089186
OpenTechnical

OT-2026-000089186

Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
19e05fa520956b5b12a01b736a92e12eb8a430fd4b984c5fdb38fa4738453eab

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089186, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089186.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089186" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089186" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089186 Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089186 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089186 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089186 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089186", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18490, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "84d65ca0a33745d349fe749dced948e5b51bd76223e5e2ea0c384fbe83feaf8f" }, { "bytes": 8057, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5f0f7cac60bdcaa66a39cc894c95b79c90938914006c22312c67dc3b73b30d11" }, { "bytes": 7716, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "19e05fa520956b5b12a01b736a92e12eb8a430fd4b984c5fdb38fa4738453eab" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089186/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089186", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7c14-93ce-e131e6dcfb9a" } oItQBmxakpykfyn+2rlGXGDqHsvHYnijsy+KZcJ735y0UPa98M8ILaAirWr7Nvl1BVF/KP/UpgfGUSt9Uz0JAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: oItQBmxakpykfyn+2rlGXGDqHsvHYnijsy+KZcJ735y0UPa98M8ILaAirWr7Nvl1BVF/KP/UpgfGUSt9Uz0JAw== {"files":[{"bytes":19305,"name":"index.html","sha256":"6d6764e49873feb94720040f588023a91e302a418e93d0851d1c16826c142bb2"},{"bytes":8758,"name":"publication.md","sha256":"9110ef90df3a5c36e3346044ef2a83dacfdc212ab0c42d72b2eb93e501bd4ecf"},{"bytes":8411,"name":"publication.txt","sha256":"e29e02b3ea84cb8b9b0c8143089fcaece4d0502da33794e9ec79ef4750f16eb6"},{"bytes":2872,"name":"manifest.json","sha256":"80934068436618c8a8a5396054363b20d716a4fcbfbca08a346a0eddcf290ee6"},{"bytes":89,"name":"manifest.sig","sha256":"08067f45865f677d0ac35b00d0ecfa590ac374d3557ae54feac52c5b0dea3a32"},{"bytes":227,"name":"manifest.sig.txt","sha256":"47c9db3a059620ace7b17d2c0789219a044f0cd77eb3d6342d0ae4790acedb03"}],"publication_id":"OT-2026-000089187"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089187
OpenTechnical

OT-2026-000089187

Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e29e02b3ea84cb8b9b0c8143089fcaece4d0502da33794e9ec79ef4750f16eb6

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089187, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089187.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089187" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089187" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089187 Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089187 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089187 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089187 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089187", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19305, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6d6764e49873feb94720040f588023a91e302a418e93d0851d1c16826c142bb2" }, { "bytes": 8758, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9110ef90df3a5c36e3346044ef2a83dacfdc212ab0c42d72b2eb93e501bd4ecf" }, { "bytes": 8411, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e29e02b3ea84cb8b9b0c8143089fcaece4d0502da33794e9ec79ef4750f16eb6" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089187/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089187", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7c7d-b0f7-0b82bc4ed18d" } C8KBmhlvQ0GpSuvWRFgUJRxERhEU8H5X7QnaCXp0ZOItUuy2x2vzkblXqcq5DawyQNNzz4koo1WEIF1/GWyOAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: C8KBmhlvQ0GpSuvWRFgUJRxERhEU8H5X7QnaCXp0ZOItUuy2x2vzkblXqcq5DawyQNNzz4koo1WEIF1/GWyOAQ== {"files":[{"bytes":19052,"name":"index.html","sha256":"e6dc6c2453f53838881e84156791669d1249c05f94360ab866fa6ae773a3ff04"},{"bytes":8548,"name":"publication.md","sha256":"26af2504b63fc27024a7ae436346b6d558bfec116644f28340491f3f7e1a4666"},{"bytes":8201,"name":"publication.txt","sha256":"d2c695e3e209d1e8fb456a6e9086739bffc29bca0b834c1922475945bfa8325c"},{"bytes":2872,"name":"manifest.json","sha256":"279b87b6745f9840474e675a74036c207de2f002a95428491632431a2689dfa9"},{"bytes":89,"name":"manifest.sig","sha256":"988391f84f214d860d0cf5cbce52fbd7ca4fad0a7b502ff58b86a01b9f350147"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1f3dfa6fda5ad4d4cbe4aa18a3827d3aff5a67bf4b56c7deb3d1f9c6b830c89f"}],"publication_id":"OT-2026-000089188"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089188
OpenTechnical

OT-2026-000089188

Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
d2c695e3e209d1e8fb456a6e9086739bffc29bca0b834c1922475945bfa8325c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089188, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089188.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089188" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089188" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089188 Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089188 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089188 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089188 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089188", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19052, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "e6dc6c2453f53838881e84156791669d1249c05f94360ab866fa6ae773a3ff04" }, { "bytes": 8548, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "26af2504b63fc27024a7ae436346b6d558bfec116644f28340491f3f7e1a4666" }, { "bytes": 8201, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d2c695e3e209d1e8fb456a6e9086739bffc29bca0b834c1922475945bfa8325c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089188/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089188", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7583-b2bc-215da786c7e4" } 2kIbNeYjbaOX52AmhuMGindEcw5rMNDnvdQDJ97ihSuG+WsmPVt6FarqoUh7/cf8B/245FGVYOLEzMBcn/TmCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 2kIbNeYjbaOX52AmhuMGindEcw5rMNDnvdQDJ97ihSuG+WsmPVt6FarqoUh7/cf8B/245FGVYOLEzMBcn/TmCQ== {"files":[{"bytes":18491,"name":"index.html","sha256":"3e8a02eaf9911fbc660ac1967b4a4b817c309b36281dec00d07863d54ebc6d65"},{"bytes":8058,"name":"publication.md","sha256":"e43ef1ba312db25f4f0ea40783f2f7575cf993aaaaaef6a06246bd1dfac30555"},{"bytes":7717,"name":"publication.txt","sha256":"bda2673e377689e86c6415d34c342a35ad346b0a77c40725de3f3cfe6e16a212"},{"bytes":2860,"name":"manifest.json","sha256":"62a00ef7f630dc5d8e31f1ffd9cf8845509d1c5fadfda486c3f603f8e2d913eb"},{"bytes":89,"name":"manifest.sig","sha256":"64a2b977bb4e579df0181c5e19d401a76a903385f502456eb704fa55a3713299"},{"bytes":227,"name":"manifest.sig.txt","sha256":"931b0c5a29631150aa6e3415f7ef6462f018fdee7ed426e9c025dcaa08398921"}],"publication_id":"OT-2026-000089189"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089189
OpenTechnical

OT-2026-000089189

Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
bda2673e377689e86c6415d34c342a35ad346b0a77c40725de3f3cfe6e16a212

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089189, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089189.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089189" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089189" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089189 Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089189 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089189 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089189 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089189", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18491, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3e8a02eaf9911fbc660ac1967b4a4b817c309b36281dec00d07863d54ebc6d65" }, { "bytes": 8058, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e43ef1ba312db25f4f0ea40783f2f7575cf993aaaaaef6a06246bd1dfac30555" }, { "bytes": 7717, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "bda2673e377689e86c6415d34c342a35ad346b0a77c40725de3f3cfe6e16a212" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089189/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089189", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7bb2-887e-fe3b0adfc46a" } eNJhOg/atbwIG//w3J4zghvWBQVGPLXMg5Ig8fU/XYQPuYQN9DUbrVlarQH/YlAZ/jcGToNcm+5DQ1goHy9KBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: eNJhOg/atbwIG//w3J4zghvWBQVGPLXMg5Ig8fU/XYQPuYQN9DUbrVlarQH/YlAZ/jcGToNcm+5DQ1goHy9KBQ== {"files":[{"bytes":19306,"name":"index.html","sha256":"46ada25867f0fea39aaeab0990d4890334faa91e53b3b234819569a3630adc7a"},{"bytes":8759,"name":"publication.md","sha256":"0ac455c7b387bde21ca90ab91d127284910a454effd7884ad025f32623143a34"},{"bytes":8412,"name":"publication.txt","sha256":"cfef0710a895f7546968bebc6b9417a370b5babc08785f6ce0c11f13e14ae0e7"},{"bytes":2872,"name":"manifest.json","sha256":"310447181370563310359390061c45a8cb1d3eaf651b64546a3014bbe98c393c"},{"bytes":89,"name":"manifest.sig","sha256":"668bb39219cc65f67ebcf7a120fd5d9d25d46491a10bb9cf6aa7ddb1751354b1"},{"bytes":227,"name":"manifest.sig.txt","sha256":"af1318b50be833bea9f99a7f1c07072b7aba8486a8248ad0eb1160e865e6cc84"}],"publication_id":"OT-2026-000089190"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089190
OpenTechnical

OT-2026-000089190

Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cfef0710a895f7546968bebc6b9417a370b5babc08785f6ce0c11f13e14ae0e7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089190, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089190.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089190" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089190" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089190 Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089190 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089190 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089190 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089190", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19306, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "46ada25867f0fea39aaeab0990d4890334faa91e53b3b234819569a3630adc7a" }, { "bytes": 8759, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0ac455c7b387bde21ca90ab91d127284910a454effd7884ad025f32623143a34" }, { "bytes": 8412, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cfef0710a895f7546968bebc6b9417a370b5babc08785f6ce0c11f13e14ae0e7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089190/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089190", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7000-baa8-abe8826e0433" } 9qaXNQZ633xGrpvyG+TrAY58QCLZCHQASkvmmkcoAmM+k/9VER2v/UUCniQS2NsjFJ5vUfJ+bJ+kpKShBGWUCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 9qaXNQZ633xGrpvyG+TrAY58QCLZCHQASkvmmkcoAmM+k/9VER2v/UUCniQS2NsjFJ5vUfJ+bJ+kpKShBGWUCA== {"files":[{"bytes":19053,"name":"index.html","sha256":"857c6c14f79696070f0a98ab01bd6448e2cfdcb80942c1255df0d13174c12008"},{"bytes":8549,"name":"publication.md","sha256":"4b09e3fc4f91c49db25fc739d7879d20ea70eebe43e4a5245c7203864cc9f637"},{"bytes":8202,"name":"publication.txt","sha256":"58a187bea042a51c847dd08cfb6cdab8563775607054ae5d261b7b65b309cb36"},{"bytes":2872,"name":"manifest.json","sha256":"0325d33a4cf41560096c906bdc288691f7e17a154d890eb04117ad237e74c3f0"},{"bytes":89,"name":"manifest.sig","sha256":"d38ef3bf3918d6f18655f64254725bb35224e921967d2c72b75c01db0131a69e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"6dc73240b8c8d19a064c7e5aec6f068c270c35a10805f9ca55350c9f9dbbb8e5"}],"publication_id":"OT-2026-000089191"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089191
OpenTechnical

OT-2026-000089191

Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
58a187bea042a51c847dd08cfb6cdab8563775607054ae5d261b7b65b309cb36

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089191, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089191.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089191" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089191" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089191 Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089191 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089191 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089191 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089191", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19053, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "857c6c14f79696070f0a98ab01bd6448e2cfdcb80942c1255df0d13174c12008" }, { "bytes": 8549, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4b09e3fc4f91c49db25fc739d7879d20ea70eebe43e4a5245c7203864cc9f637" }, { "bytes": 8202, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "58a187bea042a51c847dd08cfb6cdab8563775607054ae5d261b7b65b309cb36" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089191/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089191", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-723f-96b6-dfbe94d8fe8b" } Laae/H+Mn7Ea158gv6oqE/uYuAJCucFS03Pv3eYroMumOlNwLKB6f70dh6kbWgeXHsbdURSjIJe8B/vmqsEbDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Laae/H+Mn7Ea158gv6oqE/uYuAJCucFS03Pv3eYroMumOlNwLKB6f70dh6kbWgeXHsbdURSjIJe8B/vmqsEbDw== {"files":[{"bytes":18495,"name":"index.html","sha256":"a0c07ed5f34eb2bd47e8778d81d2ec68596dc4057ac6886dd3832af175c6bc60"},{"bytes":8062,"name":"publication.md","sha256":"8630df29f3a484dff9ac891ae69ce1fff115079b08ae7b5cc0fd95cc17e68f81"},{"bytes":7721,"name":"publication.txt","sha256":"4577bf64d5790f9bcc07b7706c37457e2b36d34cd7b84968aa1666e329911d9c"},{"bytes":2860,"name":"manifest.json","sha256":"58c51e4b8fd6c7f93e669e86219bfe13c42c69a620a37765b9ca221602d123c6"},{"bytes":89,"name":"manifest.sig","sha256":"a9ac11674684cd0f059edaf5a0bc3710bd2c35c47c61e1e7d6319cff3d58262f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"421157bf21bea9a6810126873254098d8782aff09ad57b28366db3aaa39f0a81"}],"publication_id":"OT-2026-000089192"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089192
OpenTechnical

OT-2026-000089192

Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
4577bf64d5790f9bcc07b7706c37457e2b36d34cd7b84968aa1666e329911d9c

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089192, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089192.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089192" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089192" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089192 Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089192 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089192 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089192 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089192", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18495, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a0c07ed5f34eb2bd47e8778d81d2ec68596dc4057ac6886dd3832af175c6bc60" }, { "bytes": 8062, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8630df29f3a484dff9ac891ae69ce1fff115079b08ae7b5cc0fd95cc17e68f81" }, { "bytes": 7721, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4577bf64d5790f9bcc07b7706c37457e2b36d34cd7b84968aa1666e329911d9c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089192/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089192", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-79c5-aaf9-a46655428076" } AtdTxzdNmWNKSr89TvTorabr1/2TSS06bXIoe05+QmL25EFfjbWaVOQcEwrf15PW6lHWW00A7PVE9R9VFKpsCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: AtdTxzdNmWNKSr89TvTorabr1/2TSS06bXIoe05+QmL25EFfjbWaVOQcEwrf15PW6lHWW00A7PVE9R9VFKpsCw== {"files":[{"bytes":19310,"name":"index.html","sha256":"3f457951ca025bc0c4e67ca6d1d3d1112d73f72ef4a288a9b5ac76c8d8f7bb01"},{"bytes":8763,"name":"publication.md","sha256":"d3c76532b1763a178efe89cb832f6b48d679f1cefd96dd41096b60af13c7b125"},{"bytes":8416,"name":"publication.txt","sha256":"1baeb37d6358a356d049fd59b425dcd6b676f1c5a0f70e12517ae91e2efb7ce5"},{"bytes":2872,"name":"manifest.json","sha256":"75a1425227ef8a551a3999e87c4863e12352a0182373f041954b3d839c3ddc49"},{"bytes":89,"name":"manifest.sig","sha256":"3be40d788cc6973f48dc95984f1c06d25fc3ed3ebf484e553a00fabd40e4ad80"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f51b7f94afdd66521d37e924ebbbe244c9090df04970ef2764d967412c2d693a"}],"publication_id":"OT-2026-000089193"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089193
OpenTechnical

OT-2026-000089193

Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
1baeb37d6358a356d049fd59b425dcd6b676f1c5a0f70e12517ae91e2efb7ce5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089193, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089193.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089193" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089193" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089193 Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089193 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089193 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089193 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089193", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19310, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3f457951ca025bc0c4e67ca6d1d3d1112d73f72ef4a288a9b5ac76c8d8f7bb01" }, { "bytes": 8763, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d3c76532b1763a178efe89cb832f6b48d679f1cefd96dd41096b60af13c7b125" }, { "bytes": 8416, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1baeb37d6358a356d049fd59b425dcd6b676f1c5a0f70e12517ae91e2efb7ce5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089193/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089193", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-71ee-86b2-2b3903b10410" } cSOmq52s80y4tJpx5iQvFoRchP4uSnk1ocj1qLD0sx8+48Wp8Mgv3sPDu1WCTZ4/bo/6TPLHTFU+hH4D4dhxDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: cSOmq52s80y4tJpx5iQvFoRchP4uSnk1ocj1qLD0sx8+48Wp8Mgv3sPDu1WCTZ4/bo/6TPLHTFU+hH4D4dhxDg== {"files":[{"bytes":19057,"name":"index.html","sha256":"beaedd1624025d45cb5c2ee2a56d0dcbf1c5ea115bdb03df99fd8b59819e2c2d"},{"bytes":8553,"name":"publication.md","sha256":"dffb0fb774c05264ed82473d1f87a2d9b041f5dc698afbdf5f9f6ff4826171c6"},{"bytes":8206,"name":"publication.txt","sha256":"a63eb21f54691c4d5eec94ed7c7aa5cc1e43089ff1d08fdee17605b6aa7e6959"},{"bytes":2872,"name":"manifest.json","sha256":"64343c2a1d7152db25d44a163fc36254a4f250241a87daf311bd846c5bc96dc9"},{"bytes":89,"name":"manifest.sig","sha256":"86b4ae0b80325138f332a265318fd7dbce6d23b7013716e0eb4c70dc50ca8430"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ef9484e7872ca90d4574fad02c5a92f7b4959472d33ad8ce6ee3c2ef50abd70d"}],"publication_id":"OT-2026-000089194"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089194
OpenTechnical

OT-2026-000089194

Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a63eb21f54691c4d5eec94ed7c7aa5cc1e43089ff1d08fdee17605b6aa7e6959

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089194, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089194.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089194" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089194" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089194 Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089194 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089194 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089194 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089194", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19057, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "beaedd1624025d45cb5c2ee2a56d0dcbf1c5ea115bdb03df99fd8b59819e2c2d" }, { "bytes": 8553, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "dffb0fb774c05264ed82473d1f87a2d9b041f5dc698afbdf5f9f6ff4826171c6" }, { "bytes": 8206, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a63eb21f54691c4d5eec94ed7c7aa5cc1e43089ff1d08fdee17605b6aa7e6959" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089194/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089194", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-781e-b64e-9658baef29d5" } dB4vVuNogNeycRgoliM6YTtp32Mas1HiHwnXCq+HK7mVcyEuJub3kqHGQKm+oy6Q+Y5EMC1MLhS36pcuYeOSBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: dB4vVuNogNeycRgoliM6YTtp32Mas1HiHwnXCq+HK7mVcyEuJub3kqHGQKm+oy6Q+Y5EMC1MLhS36pcuYeOSBQ== {"files":[{"bytes":18676,"name":"index.html","sha256":"b29662b3c42925426c3e13dac731d4d1393aafb91e1f9c5638e69e6fceafcfa3"},{"bytes":8213,"name":"publication.md","sha256":"3956fb9707f4823f1e5fa06fb3e004945d31406881be14ab96d5b21f100bb755"},{"bytes":7883,"name":"publication.txt","sha256":"4b2646cbc62f08be5142554c6e1ea25eb2ae51b8eeaaad7edcd83ebdb8cf2613"},{"bytes":2837,"name":"manifest.json","sha256":"0d40dcaaf04d3c492f331890a2367c031f5612cd602f4b3cddb6820adae091a5"},{"bytes":89,"name":"manifest.sig","sha256":"16c9f466fc2a22198daa16d36762c18001b1a2fe4fb3578f689574fdeb0d78d4"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3fab62526d1c9e0a450fdaba5f9fe44a30caa5cf76abdd81460b4b9cc054f31f"}],"publication_id":"OT-2026-000089195"} Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089195
OpenTechnical

OT-2026-000089195

Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
4b2646cbc62f08be5142554c6e1ea25eb2ae51b8eeaaad7edcd83ebdb8cf2613

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089195, “Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089195.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089195" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089195" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089195 Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089195 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089195 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089195 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089195", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1151 }, "figures": [], "files": [ { "bytes": 18676, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b29662b3c42925426c3e13dac731d4d1393aafb91e1f9c5638e69e6fceafcfa3" }, { "bytes": 8213, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3956fb9707f4823f1e5fa06fb3e004945d31406881be14ab96d5b21f100bb755" }, { "bytes": 7883, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4b2646cbc62f08be5142554c6e1ea25eb2ae51b8eeaaad7edcd83ebdb8cf2613" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089195/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089195", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7a6d-91e3-d09f0bc6a3c7" } +6/oBznUSbKWrDuwO5sx/kM/XR5HctHmatoWK/IMrm39nXHAKciroVDrVGEGCs4ygyUVMwKv2SP1ZD3/7f8TDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: +6/oBznUSbKWrDuwO5sx/kM/XR5HctHmatoWK/IMrm39nXHAKciroVDrVGEGCs4ygyUVMwKv2SP1ZD3/7f8TDQ== {"files":[{"bytes":19491,"name":"index.html","sha256":"80ca3c9df563126c1dfd0aae7f9e3e8cde6c28f7cfa29f901dffff9fa9cf8b75"},{"bytes":8914,"name":"publication.md","sha256":"21c35ce309731f712b6716169afe86460578acee8074784fa71d7f3eed08d165"},{"bytes":8578,"name":"publication.txt","sha256":"871892166a61644e620a255cbe9b33fdc4ce7bc39f8cebb96369ade77e79b5eb"},{"bytes":2849,"name":"manifest.json","sha256":"e265c8e82a546dd46b893dcec383439907105c655665d50419b116c579808848"},{"bytes":89,"name":"manifest.sig","sha256":"f765bb74b1e41f1bb067c7792f3b6e87147bfd3574d4731fd63f3383196cb579"},{"bytes":227,"name":"manifest.sig.txt","sha256":"24eaa1c84af586de7694293f0ef0158f072e2fab237098850680163e16e76573"}],"publication_id":"OT-2026-000089196"} Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089196
OpenTechnical

OT-2026-000089196

Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
871892166a61644e620a255cbe9b33fdc4ce7bc39f8cebb96369ade77e79b5eb

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089196, “Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089196.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089196" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089196" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089196 Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089196 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089196 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089196 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089196", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1257 }, "figures": [], "files": [ { "bytes": 19491, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "80ca3c9df563126c1dfd0aae7f9e3e8cde6c28f7cfa29f901dffff9fa9cf8b75" }, { "bytes": 8914, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "21c35ce309731f712b6716169afe86460578acee8074784fa71d7f3eed08d165" }, { "bytes": 8578, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "871892166a61644e620a255cbe9b33fdc4ce7bc39f8cebb96369ade77e79b5eb" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089196/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089196", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7a3c-a1bc-c13d4341f1fb" } 5okQ4l34aBnvo12Re5TSw9Pv/xap6E5h1EJYZBgbtRawtmrizhnKDeUR9QqoIEcFJgbgSJR51lWSY6pY/JsHBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 5okQ4l34aBnvo12Re5TSw9Pv/xap6E5h1EJYZBgbtRawtmrizhnKDeUR9QqoIEcFJgbgSJR51lWSY6pY/JsHBw== {"files":[{"bytes":19238,"name":"index.html","sha256":"084debe6322e101fccb80985d3a6505ecd7ce697b44a3e1c3a9d6e5a1434d00b"},{"bytes":8704,"name":"publication.md","sha256":"7966f3133af1748618656e14a037330599c5019cb418c65d2e93421c92fb369e"},{"bytes":8368,"name":"publication.txt","sha256":"1309203f110fb1315c1dfe28de226f1fc2e5491cad52d5f76c2494930b896d90"},{"bytes":2849,"name":"manifest.json","sha256":"04fa62c1a0aa0249039e6e5aaa82cf958e6f119c461bf42fc59d0967c1efa540"},{"bytes":89,"name":"manifest.sig","sha256":"b80fa9e9c7a38faa137478818195578ad7c91e85d5c89702acd84d143ac21f78"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1109442f2e428b2f73bb4588e0a7681865b01459732321638f6316e67477f728"}],"publication_id":"OT-2026-000089197"} Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089197
OpenTechnical

OT-2026-000089197

Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
1309203f110fb1315c1dfe28de226f1fc2e5491cad52d5f76c2494930b896d90

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089197, “Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089197.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089197" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089197" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089197 Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089197 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089197 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089197 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089197", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1222 }, "figures": [], "files": [ { "bytes": 19238, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "084debe6322e101fccb80985d3a6505ecd7ce697b44a3e1c3a9d6e5a1434d00b" }, { "bytes": 8704, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7966f3133af1748618656e14a037330599c5019cb418c65d2e93421c92fb369e" }, { "bytes": 8368, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1309203f110fb1315c1dfe28de226f1fc2e5491cad52d5f76c2494930b896d90" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089197/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089197", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-75a3-bcca-84cced2a1991" } WRH9sbxrc4NhLTnvIFKctwHdn5PKI4MKJQmB9VscZB6F3xg7eWppG9b+HeJmKYLmkWnjU6GL/rLG7JJs2jeECw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: WRH9sbxrc4NhLTnvIFKctwHdn5PKI4MKJQmB9VscZB6F3xg7eWppG9b+HeJmKYLmkWnjU6GL/rLG7JJs2jeECw== {"files":[{"bytes":18622,"name":"index.html","sha256":"1efd519b45339484525d7be6a52145dacb20be4e1939dec1f36b422c732807f0"},{"bytes":8159,"name":"publication.md","sha256":"1c4d93a27af9753e4b1cc2e9a6a0c9556fb8f01f5d84c787208c56133b0d98c0"},{"bytes":7829,"name":"publication.txt","sha256":"2ab700b310e56a0989ce8b29558afaa41ae97b85a81b707abae825da572790db"},{"bytes":2837,"name":"manifest.json","sha256":"50e058fede68060d768b51e9696a47bb4018645c445db2a3d2560f406a852324"},{"bytes":89,"name":"manifest.sig","sha256":"4da93371570ed4e4fed13c04c830d9a326f80f3da554112fa5e7f72b2e3c832f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d3b75b1e6c9f7c0fbc7aeca7f99abba348d14c0ed548d6a1f4742371a4d04ebc"}],"publication_id":"OT-2026-000089198"} Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089198
OpenTechnical

OT-2026-000089198

Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
2ab700b310e56a0989ce8b29558afaa41ae97b85a81b707abae825da572790db

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089198, “Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089198.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089198" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089198" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089198 Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089198 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089198 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089198 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089198", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1136 }, "figures": [], "files": [ { "bytes": 18622, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1efd519b45339484525d7be6a52145dacb20be4e1939dec1f36b422c732807f0" }, { "bytes": 8159, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1c4d93a27af9753e4b1cc2e9a6a0c9556fb8f01f5d84c787208c56133b0d98c0" }, { "bytes": 7829, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2ab700b310e56a0989ce8b29558afaa41ae97b85a81b707abae825da572790db" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089198/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089198", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7e2c-a2ef-4b909e03e86b" } 9f9Y5NS/beSQKse6G7Spu6ikxLyEWKrPsnYyjBpSdgxLA7TvZmS++lbYKQUH4WNqLb1Hppa5VQWRbqq8ommwCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 9f9Y5NS/beSQKse6G7Spu6ikxLyEWKrPsnYyjBpSdgxLA7TvZmS++lbYKQUH4WNqLb1Hppa5VQWRbqq8ommwCA== {"files":[{"bytes":19437,"name":"index.html","sha256":"acc8e90f028268cf8957fbae71dafbf7d29ec5c18a2d37a95309524655ccc83e"},{"bytes":8860,"name":"publication.md","sha256":"e4993222362e81b1320e9439c2cf36ed6dc22da7fee03753adfbf06574094a6c"},{"bytes":8524,"name":"publication.txt","sha256":"12127aa8842d3f16d49ea2adce9f0ef4a0bb30c8dee39fcdb0906fd8ad1fbedb"},{"bytes":2849,"name":"manifest.json","sha256":"2256ee1d2995fe436d588c7cbc19072a89fc587fe31b6f4dc8f019bce44881a3"},{"bytes":89,"name":"manifest.sig","sha256":"0387bb683f1678c2c65bbba25293bd8bba19f493defa41d0b3cff85bbd78d110"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3fedc8ff6ca80bffa28f431189adb2c190b9dac24fedbe2c21222f319140f965"}],"publication_id":"OT-2026-000089199"} Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089199
OpenTechnical

OT-2026-000089199

Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
12127aa8842d3f16d49ea2adce9f0ef4a0bb30c8dee39fcdb0906fd8ad1fbedb

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089199, “Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089199.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089199" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089199" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089199 Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089199 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089199 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089199 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089199", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1242 }, "figures": [], "files": [ { "bytes": 19437, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "acc8e90f028268cf8957fbae71dafbf7d29ec5c18a2d37a95309524655ccc83e" }, { "bytes": 8860, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e4993222362e81b1320e9439c2cf36ed6dc22da7fee03753adfbf06574094a6c" }, { "bytes": 8524, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "12127aa8842d3f16d49ea2adce9f0ef4a0bb30c8dee39fcdb0906fd8ad1fbedb" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089199/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089199", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7241-99f7-68713294b549" } Q44gM+pTWdzd4QR9B/Bl94HltrPt1WV0C1wtXjZDNKzcL9LAVn5VBIz+22enigRvsnipUF9igB12RGZzyls5Aw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Q44gM+pTWdzd4QR9B/Bl94HltrPt1WV0C1wtXjZDNKzcL9LAVn5VBIz+22enigRvsnipUF9igB12RGZzyls5Aw== {"files":[{"bytes":19184,"name":"index.html","sha256":"955ee8f72245f7897fcc75eb58bd14ec3de91fc82b097041582e0db4c3cd9590"},{"bytes":8650,"name":"publication.md","sha256":"fee92c01495df10ff2eeac45c1c4575a1115064495be9dac00441533dbd1100c"},{"bytes":8314,"name":"publication.txt","sha256":"cfab76cba5314f2aa906b5553e2c4c3b11910231a3dbbff230dace3387059a4b"},{"bytes":2849,"name":"manifest.json","sha256":"a0899919bc4eabfefc06adef41bcab8e4bccd4c8faffd58ab672ba3c8d8d1de1"},{"bytes":89,"name":"manifest.sig","sha256":"2413afdfea36826a5fbd4cc88ec92afa0a08adacff41d58af6a96fe896f73455"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a011b23e4244e0896c47ead7f02ffe32a9e9881f363619d1552dfeb2741c6f9d"}],"publication_id":"OT-2026-000089200"} Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089200
OpenTechnical

OT-2026-000089200

Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cfab76cba5314f2aa906b5553e2c4c3b11910231a3dbbff230dace3387059a4b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089200, “Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089200.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089200" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089200" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089200 Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089200 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089200 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089200 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089200", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1207 }, "figures": [], "files": [ { "bytes": 19184, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "955ee8f72245f7897fcc75eb58bd14ec3de91fc82b097041582e0db4c3cd9590" }, { "bytes": 8650, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fee92c01495df10ff2eeac45c1c4575a1115064495be9dac00441533dbd1100c" }, { "bytes": 8314, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cfab76cba5314f2aa906b5553e2c4c3b11910231a3dbbff230dace3387059a4b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089200/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089200", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7dc6-b9ca-3562079ea8cf" } wYVhfN24uQFxsfEaJQrquyuIlGGO1EWKqT4alCNniGkKs+wWDs8lGA6kdYEpJwU6mQn8+SSCIdYEb2Dfc7T9CQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: wYVhfN24uQFxsfEaJQrquyuIlGGO1EWKqT4alCNniGkKs+wWDs8lGA6kdYEpJwU6mQn8+SSCIdYEb2Dfc7T9CQ== {"files":[{"bytes":18384,"name":"index.html","sha256":"f8099184e8d83d7e22effb23f41e36ba05ff3e62e223dcecbb3f731aebb7b6b3"},{"bytes":7967,"name":"publication.md","sha256":"4773ed9f70bd79b33a1c4a9450d463847c1ba7ed67a9116bd8a41727651ce993"},{"bytes":7634,"name":"publication.txt","sha256":"d4e81f181a6d70d29dc4e236cc6195fca9b3bcee04df5edab671344cf66e9cc4"},{"bytes":2852,"name":"manifest.json","sha256":"70c437d677ba78e639e862875a3afac1f51357faf525db29cbcfd6d2d4e67836"},{"bytes":89,"name":"manifest.sig","sha256":"5330375dfff36232e967eed2e9118eec68479a6f73f19d550cd1660a8b29be70"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f612e24bde9ab944d51325e78a1582c1e46c1bd1234025dc70a6b7e5326f0317"}],"publication_id":"OT-2026-000089201"} Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089201
OpenTechnical

OT-2026-000089201

Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
d4e81f181a6d70d29dc4e236cc6195fca9b3bcee04df5edab671344cf66e9cc4

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089201, “Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089201.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089201" title: "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089201" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089201 Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089201 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089201 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089201 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089201", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18384, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f8099184e8d83d7e22effb23f41e36ba05ff3e62e223dcecbb3f731aebb7b6b3" }, { "bytes": 7967, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4773ed9f70bd79b33a1c4a9450d463847c1ba7ed67a9116bd8a41727651ce993" }, { "bytes": 7634, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d4e81f181a6d70d29dc4e236cc6195fca9b3bcee04df5edab671344cf66e9cc4" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089201/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089201", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7f0f-b551-6a241d47e512" } Qc25q08/CNP1IUd/319FpaOyvhWu9QVIFRjBAzGwA2/xhkX8TwYlYvbM0jRU9529iC6+DzdGV1/Kqx9ZWrzcDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Qc25q08/CNP1IUd/319FpaOyvhWu9QVIFRjBAzGwA2/xhkX8TwYlYvbM0jRU9529iC6+DzdGV1/Kqx9ZWrzcDg== {"files":[{"bytes":19199,"name":"index.html","sha256":"07c436869e585b339bc21092669fa9f3738dff6efde3ff4adbe5b7d865db2491"},{"bytes":8668,"name":"publication.md","sha256":"6c70ca3c45aacb08cb11e7302b0f91db4d7f681f8bed250d9154f29cc27a6397"},{"bytes":8329,"name":"publication.txt","sha256":"aae519e4c7029e2cb5c4ece2cd942851da11c6a1fcbbbb6f7b5d43190e027327"},{"bytes":2864,"name":"manifest.json","sha256":"12db5ef683017d2ccef6f5a38f264e2bd726568abf08cb14a823d8ac7d08e781"},{"bytes":89,"name":"manifest.sig","sha256":"cb84dac4804c7704f8ab1e60b542a1d1607d87b45fb1e80e674fdffb2072fceb"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3eb0f2cabcd661bbcb89c3cd4f1252fe72eb52331c461fb169c122a37fa31787"}],"publication_id":"OT-2026-000089202"} Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089202
OpenTechnical

OT-2026-000089202

Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
aae519e4c7029e2cb5c4ece2cd942851da11c6a1fcbbbb6f7b5d43190e027327

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089202, “Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089202.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089202" title: "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089202" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089202 Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089202 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089202 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089202 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089202", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19199, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "07c436869e585b339bc21092669fa9f3738dff6efde3ff4adbe5b7d865db2491" }, { "bytes": 8668, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "6c70ca3c45aacb08cb11e7302b0f91db4d7f681f8bed250d9154f29cc27a6397" }, { "bytes": 8329, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "aae519e4c7029e2cb5c4ece2cd942851da11c6a1fcbbbb6f7b5d43190e027327" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089202/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089202", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-79a3-9df2-52650743625d" } IzUVrjWro6Xdj5w41CKC0kFXwKoE91vl927Q3yXSI2lcR7SvPceuj9fTbg3ynyfB6NJgBaSVz0GO02DAJs0EBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: IzUVrjWro6Xdj5w41CKC0kFXwKoE91vl927Q3yXSI2lcR7SvPceuj9fTbg3ynyfB6NJgBaSVz0GO02DAJs0EBQ== {"files":[{"bytes":18946,"name":"index.html","sha256":"8a1b0ab33e10e099a0bf8b736433c4cd7f1813ba9ec16a42a7718289fba190c9"},{"bytes":8458,"name":"publication.md","sha256":"89d3b92654180efca229a3f6aac333f1e00186f50d107bb17ffe0d8b590631d1"},{"bytes":8119,"name":"publication.txt","sha256":"c02ff212aea40184f64884c9c52f5f7136155324eec5714bee6d97c43afe0271"},{"bytes":2864,"name":"manifest.json","sha256":"0a69a5057078e1aabed72c20f180e075afd6ed7a525d033d9385cd3d44a10138"},{"bytes":89,"name":"manifest.sig","sha256":"5e665e245018567e43c30f7752e9c10991cd5715770a1187ef71d4f45cf0f8e7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"25ce8bdf0c09412c7445c716e2aedd20fcf594c0786fa99db57fb14cae821437"}],"publication_id":"OT-2026-000089203"} Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089203
OpenTechnical

OT-2026-000089203

Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c02ff212aea40184f64884c9c52f5f7136155324eec5714bee6d97c43afe0271

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089203, “Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089203.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089203" title: "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089203" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089203 Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089203 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089203 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089203 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089203", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18946, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8a1b0ab33e10e099a0bf8b736433c4cd7f1813ba9ec16a42a7718289fba190c9" }, { "bytes": 8458, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "89d3b92654180efca229a3f6aac333f1e00186f50d107bb17ffe0d8b590631d1" }, { "bytes": 8119, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c02ff212aea40184f64884c9c52f5f7136155324eec5714bee6d97c43afe0271" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089203/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089203", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-72e4-a369-2b125f3f609e" } c50Aqz5qW+ObwLj817xqOhq3WpglnGiSzrD14LrAdlGZOeFNlghQFGQ26cR1kwFhljdcsZ6pLORToj33KA3PBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: c50Aqz5qW+ObwLj817xqOhq3WpglnGiSzrD14LrAdlGZOeFNlghQFGQ26cR1kwFhljdcsZ6pLORToj33KA3PBA== {"files":[{"bytes":18384,"name":"index.html","sha256":"19ceab8f2db282dfb70faf3a8bcb6dc63f2786318f268b3e59d358c534cb8ec1"},{"bytes":7967,"name":"publication.md","sha256":"a4cd076fd3de080196939ecb15f333fd6d74a7112e046918ed43a19a310aaa0b"},{"bytes":7634,"name":"publication.txt","sha256":"165cebb0ed28bb0a6baa30fd599b0519da6c294009311bcc701efee80fdd6060"},{"bytes":2852,"name":"manifest.json","sha256":"df43b20d39a69fc8d9cf0001fcdfa1a9bcbc496740cfd8ccdddfc5e909625614"},{"bytes":89,"name":"manifest.sig","sha256":"593da1d90a868ac428ff8f4e1602a09007fd9203c558755143dfcf1a0cbdbd39"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3a604ff261e05bb0914945eb0f8c41c3f06d090bcbb6e183405e2a68ee1c33f2"}],"publication_id":"OT-2026-000089204"} Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089204
OpenTechnical

OT-2026-000089204

Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
165cebb0ed28bb0a6baa30fd599b0519da6c294009311bcc701efee80fdd6060

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089204, “Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089204.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089204" title: "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089204" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089204 Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089204 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089204 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089204 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089204", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18384, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "19ceab8f2db282dfb70faf3a8bcb6dc63f2786318f268b3e59d358c534cb8ec1" }, { "bytes": 7967, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a4cd076fd3de080196939ecb15f333fd6d74a7112e046918ed43a19a310aaa0b" }, { "bytes": 7634, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "165cebb0ed28bb0a6baa30fd599b0519da6c294009311bcc701efee80fdd6060" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089204/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089204", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7823-8266-2d354d8d4a14" } q22CmxMWWFvO4Fv08BWzaD4UT5V1XiZvfN/0EsbugypVZX+Fi1M1XFwdXCOSdyiuJbPrM1wrd4RCwrmiGN+8BQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: q22CmxMWWFvO4Fv08BWzaD4UT5V1XiZvfN/0EsbugypVZX+Fi1M1XFwdXCOSdyiuJbPrM1wrd4RCwrmiGN+8BQ== {"files":[{"bytes":19199,"name":"index.html","sha256":"af1a78fb922b4acc15b141fc4358bcf8b5ef4e5499b7f858c5e25495b911dc33"},{"bytes":8668,"name":"publication.md","sha256":"71f41b8f43e564a46031ed4696f9d5edf52efe645e9e3516db141321e91cfd91"},{"bytes":8329,"name":"publication.txt","sha256":"da9f3ad190092a84b2556b3419dd876662949e132c4735dea794682aa661806f"},{"bytes":2864,"name":"manifest.json","sha256":"64bdf6656d45e89c0c55a2fd32c6c2c459d2971f1f84fcabfca7aba0a4b410fb"},{"bytes":89,"name":"manifest.sig","sha256":"716d6de90d9ccb6ee7cb6cc060ec2828e608eaca4e37e7b3bc2fdc6ec68b5e21"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a307c9f8043520ca788d4cb04862341be65cb33299292ca91b305999b5a256ae"}],"publication_id":"OT-2026-000089205"} Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089205
OpenTechnical

OT-2026-000089205

Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
da9f3ad190092a84b2556b3419dd876662949e132c4735dea794682aa661806f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089205, “Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089205.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089205" title: "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089205" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089205 Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089205 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089205 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089205 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089205", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19199, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "af1a78fb922b4acc15b141fc4358bcf8b5ef4e5499b7f858c5e25495b911dc33" }, { "bytes": 8668, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "71f41b8f43e564a46031ed4696f9d5edf52efe645e9e3516db141321e91cfd91" }, { "bytes": 8329, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "da9f3ad190092a84b2556b3419dd876662949e132c4735dea794682aa661806f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089205/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089205", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7951-a83a-7f95a9679d4a" } aVCMALO/8ZlYxy8y5yzZujbLcDHjhM2o6SzngSlhQ0xwdFQuc4e9H9IQpcT5zUe9FAT3fU9YPf/MVVRNs579Ag== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: aVCMALO/8ZlYxy8y5yzZujbLcDHjhM2o6SzngSlhQ0xwdFQuc4e9H9IQpcT5zUe9FAT3fU9YPf/MVVRNs579Ag== {"files":[{"bytes":18946,"name":"index.html","sha256":"5da3bfcda3297d3f39f62c4050affd630e56256f0bafba039520238ce2b91a03"},{"bytes":8458,"name":"publication.md","sha256":"b6e54df50c316240c5a3c8b801579f1187ddb6cd7b4e8d3dbf70023acb70ee88"},{"bytes":8119,"name":"publication.txt","sha256":"b8a9c023814104746a7e7428fbfdf9b9f201df02b064ca92902d81f76e9cc3ec"},{"bytes":2864,"name":"manifest.json","sha256":"65a1fdb2261f1ca8485b3c6d01aeec879baee777472a29d1e663becb1d396322"},{"bytes":89,"name":"manifest.sig","sha256":"69db93030254768e4f145b5c4c2b21433089b98cc2c38ff34f132fe1510f2b2f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b6717a7a4f3da8ed4635431de76cf98865a12170416ad6c8b0d9757a8cf1d492"}],"publication_id":"OT-2026-000089206"} Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089206
OpenTechnical

OT-2026-000089206

Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
b8a9c023814104746a7e7428fbfdf9b9f201df02b064ca92902d81f76e9cc3ec

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089206, “Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089206.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089206" title: "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089206" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089206 Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089206 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089206 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089206 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089206", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18946, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5da3bfcda3297d3f39f62c4050affd630e56256f0bafba039520238ce2b91a03" }, { "bytes": 8458, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b6e54df50c316240c5a3c8b801579f1187ddb6cd7b4e8d3dbf70023acb70ee88" }, { "bytes": 8119, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b8a9c023814104746a7e7428fbfdf9b9f201df02b064ca92902d81f76e9cc3ec" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089206/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089206", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, single stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7989-b170-07f710abd55a" } dsKkM364IG+sQeg90Q2Q49CAgMCp0Vh0+bbie7j5pkeckmGF7EvAHtOyjydJ2BL1i8OiRlL6uKzbWLKe54B7Ag== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: dsKkM364IG+sQeg90Q2Q49CAgMCp0Vh0+bbie7j5pkeckmGF7EvAHtOyjydJ2BL1i8OiRlL6uKzbWLKe54B7Ag== {"files":[{"bytes":18479,"name":"index.html","sha256":"bb19ecd2ed165688a37ddf10447e2d7659258973dae5430b976d598aedb4fc16"},{"bytes":8052,"name":"publication.md","sha256":"31bd8a759dcf5ba6e8185c9455b2d79f8b817a4ff55fd19ce47d21bd5f1b4fbf"},{"bytes":7714,"name":"publication.txt","sha256":"e4662e5d8519250c494ae93ec786ca9aaf1460aa1682707b573de872c8fece13"},{"bytes":2857,"name":"manifest.json","sha256":"8e5d26666ec0a8b3ba6d5672d0216e8da9ee3cad951e113ebf8235b579fa0343"},{"bytes":89,"name":"manifest.sig","sha256":"f32d2cf0cd1dac648fe606537d7a58401be5a1f136b025af9b7c9da4c478297f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"5a7249073c3a4430603ddc647b4e4d406150a5cc23b6b6ea225be82c42361704"}],"publication_id":"OT-2026-000089207"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089207
OpenTechnical

OT-2026-000089207

Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
e4662e5d8519250c494ae93ec786ca9aaf1460aa1682707b573de872c8fece13

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089207, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089207.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089207" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089207" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089207 Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089207 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089207 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089207 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089207", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18479, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bb19ecd2ed165688a37ddf10447e2d7659258973dae5430b976d598aedb4fc16" }, { "bytes": 8052, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "31bd8a759dcf5ba6e8185c9455b2d79f8b817a4ff55fd19ce47d21bd5f1b4fbf" }, { "bytes": 7714, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e4662e5d8519250c494ae93ec786ca9aaf1460aa1682707b573de872c8fece13" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089207/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089207", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7f17-8002-8a6bdac8e963" } MXeWpzCUTIBS+cTZnipUscLCI7qvXItw6N85gYjYmkOsnfwcagvYGIBnpRD2FddZGxpWR5XXf71d/e6jB+evBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: MXeWpzCUTIBS+cTZnipUscLCI7qvXItw6N85gYjYmkOsnfwcagvYGIBnpRD2FddZGxpWR5XXf71d/e6jB+evBA== {"files":[{"bytes":19294,"name":"index.html","sha256":"56a9644944953dc1c9b5b9ae3937de2d1eadd8aca81ad785c99f728fef0aece6"},{"bytes":8753,"name":"publication.md","sha256":"07bd39d6099cb2c3bb3d1861d4b536bc014434c42dd5d3acba6a42e6566b8e61"},{"bytes":8409,"name":"publication.txt","sha256":"467d4bfc345191479a48a169453073dd7a21fe4ca62d2dff168969707371b3f1"},{"bytes":2869,"name":"manifest.json","sha256":"b3d3d24034d81d959e72d4576865a5f2ce44be8f59598674cb05c3439599464b"},{"bytes":89,"name":"manifest.sig","sha256":"ee98c2ce40dac1b878d484c7cefcede441d6211911b1d4f1365d57278640df23"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e92c524e3f8ef04a0200048743dce0890dd45e2c77af24195d787fbec447c689"}],"publication_id":"OT-2026-000089208"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089208
OpenTechnical

OT-2026-000089208

Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
467d4bfc345191479a48a169453073dd7a21fe4ca62d2dff168969707371b3f1

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089208, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089208.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089208" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089208" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089208 Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089208 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089208 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089208 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089208", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19294, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "56a9644944953dc1c9b5b9ae3937de2d1eadd8aca81ad785c99f728fef0aece6" }, { "bytes": 8753, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "07bd39d6099cb2c3bb3d1861d4b536bc014434c42dd5d3acba6a42e6566b8e61" }, { "bytes": 8409, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "467d4bfc345191479a48a169453073dd7a21fe4ca62d2dff168969707371b3f1" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089208/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089208", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-771b-b067-309304a2faca" } 0ttTkVKragVTIDjZVJgGqKqeUY+p+F55uZLzEeA27a9MEkt6L0MnGMWoKbdl2FqHCBRQiSIQdtcgxCljJpwICA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 0ttTkVKragVTIDjZVJgGqKqeUY+p+F55uZLzEeA27a9MEkt6L0MnGMWoKbdl2FqHCBRQiSIQdtcgxCljJpwICA== {"files":[{"bytes":19041,"name":"index.html","sha256":"3963b59a72ebfb15a327ba45d6ce9319b816a5f127033516d2af09ced64079ba"},{"bytes":8543,"name":"publication.md","sha256":"b4baee5a3dcb18f5126de3a80e8f04282f3e276e92a21242fb5c18cfefcbe08e"},{"bytes":8199,"name":"publication.txt","sha256":"cc4d12791c738e924f8e92f171147baa38e5d41263760fa8b6cca723c11b7e8b"},{"bytes":2869,"name":"manifest.json","sha256":"8bd85132329e2c4c972fe0bfc3a93d9b500acc87b021b9082071a6c126809080"},{"bytes":89,"name":"manifest.sig","sha256":"e19d2c68a1b0ab7a2a6319da9718ea6a9f1121aaf95c23df635ebeb0be07b56c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9d2c15bbf7dc40be2156f1c4355060a4906effecea9565fe7c9a8a93d1fa5967"}],"publication_id":"OT-2026-000089209"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089209
OpenTechnical

OT-2026-000089209

Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cc4d12791c738e924f8e92f171147baa38e5d41263760fa8b6cca723c11b7e8b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089209, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089209.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089209" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089209" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089209 Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089209 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089209 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089209 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089209", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19041, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3963b59a72ebfb15a327ba45d6ce9319b816a5f127033516d2af09ced64079ba" }, { "bytes": 8543, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b4baee5a3dcb18f5126de3a80e8f04282f3e276e92a21242fb5c18cfefcbe08e" }, { "bytes": 8199, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cc4d12791c738e924f8e92f171147baa38e5d41263760fa8b6cca723c11b7e8b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089209/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089209", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7a5c-8f2f-3fae56d51b80" } JIWWoEkTHS/L6jAX7aFWH7Ew49LNVugJkjsoBXi11gO8xk0oPtgLjfo8Oez1tqvuJVIrDyS87FYXl/bcRgl6CQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: JIWWoEkTHS/L6jAX7aFWH7Ew49LNVugJkjsoBXi11gO8xk0oPtgLjfo8Oez1tqvuJVIrDyS87FYXl/bcRgl6CQ== {"files":[{"bytes":18480,"name":"index.html","sha256":"aa1c7df91da4fba629ad5c0a771782048584bf625a959c39166d52c1f8cd0067"},{"bytes":8053,"name":"publication.md","sha256":"00b638912b3c4782d2d65702761be1c54dd7519ef9ce5bc3028bf3443bd077c7"},{"bytes":7715,"name":"publication.txt","sha256":"732bbfdb9cf6dfaf744c4a28849c010eefc0752deb0706b121310f8f581074dc"},{"bytes":2857,"name":"manifest.json","sha256":"c24318df34718937716d28fcd324f85b441f3d97ccd02f8a55dad9a848e8c66f"},{"bytes":89,"name":"manifest.sig","sha256":"2c202b17a6af5bdf5b41f91b950025f7584aa0c3f2ef50fba40987a47433056f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0a47cc5b23c74bdc737af878f39bb3a9d493e814a634487ab3e58467cc32dfe3"}],"publication_id":"OT-2026-000089210"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089210
OpenTechnical

OT-2026-000089210

Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
732bbfdb9cf6dfaf744c4a28849c010eefc0752deb0706b121310f8f581074dc

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089210, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089210.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089210" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089210" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089210 Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089210 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089210 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089210 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089210", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18480, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "aa1c7df91da4fba629ad5c0a771782048584bf625a959c39166d52c1f8cd0067" }, { "bytes": 8053, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "00b638912b3c4782d2d65702761be1c54dd7519ef9ce5bc3028bf3443bd077c7" }, { "bytes": 7715, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "732bbfdb9cf6dfaf744c4a28849c010eefc0752deb0706b121310f8f581074dc" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089210/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089210", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-75e5-b74b-031902402e58" } VeIZuZqCtCkjCGKVmz3BB5X2HdiSuxgRxXMEFxKqNglWXsCnBvHwFhDMvFLllSRUPexLyZfkPCCn9xvlcqs9Cg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: VeIZuZqCtCkjCGKVmz3BB5X2HdiSuxgRxXMEFxKqNglWXsCnBvHwFhDMvFLllSRUPexLyZfkPCCn9xvlcqs9Cg== {"files":[{"bytes":19295,"name":"index.html","sha256":"1658408357dc7bd3fc914ec4650edbd684a68d1341694bd3933153337c938434"},{"bytes":8754,"name":"publication.md","sha256":"105481df3a337cf2105d10bd32ad34d64db21cb97bab6754a8f4013bfb4f0a49"},{"bytes":8410,"name":"publication.txt","sha256":"ffdf56223f39e55df15328c3365c7399fdf7bdcd1e9108271ae51b9ad557cf50"},{"bytes":2869,"name":"manifest.json","sha256":"47a23dfdf415480ecd012685b604fb4610a4dec3d89c81ede5c133d68fec12f7"},{"bytes":89,"name":"manifest.sig","sha256":"c2a7b790b20e4f3486c2f9f6f92a064db8933e9d66dc5bda58e91b96a3911000"},{"bytes":227,"name":"manifest.sig.txt","sha256":"cfeb8535578b0115310e2a5bf9de1c524f535b2575f108613c338e71abc81e48"}],"publication_id":"OT-2026-000089211"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089211
OpenTechnical

OT-2026-000089211

Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
ffdf56223f39e55df15328c3365c7399fdf7bdcd1e9108271ae51b9ad557cf50

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089211, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089211.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089211" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089211" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089211 Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089211 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089211 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089211 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089211", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19295, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1658408357dc7bd3fc914ec4650edbd684a68d1341694bd3933153337c938434" }, { "bytes": 8754, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "105481df3a337cf2105d10bd32ad34d64db21cb97bab6754a8f4013bfb4f0a49" }, { "bytes": 8410, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ffdf56223f39e55df15328c3365c7399fdf7bdcd1e9108271ae51b9ad557cf50" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089211/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089211", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7615-a893-d29e55f43dc8" } ZKOEKxCAx4vPDkh7K0JA6ShHwCphG7l/kKJL0E7KG3toDPjOhAM27L5m6F6AnKNIa0xXhQ6VjhSBPAvlhlbvAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ZKOEKxCAx4vPDkh7K0JA6ShHwCphG7l/kKJL0E7KG3toDPjOhAM27L5m6F6AnKNIa0xXhQ6VjhSBPAvlhlbvAg== {"files":[{"bytes":19042,"name":"index.html","sha256":"ab534aa8dd7230c9e80ccbeac4c89009921915663445f2abe1719a892e3cda35"},{"bytes":8544,"name":"publication.md","sha256":"8a68db8c95d6d76ef09bbaef3bcaf8a2377737fded41c6a433ce0c17f5c38c49"},{"bytes":8200,"name":"publication.txt","sha256":"c16ffd6d327c1f5ecdc7d77277cdfdc093a96aafd5a97c02a2ff46e3f2dbe958"},{"bytes":2869,"name":"manifest.json","sha256":"c3099fa372e8cc99b44aaaafbb873f58e08f4693454988d9d8e955c813637b79"},{"bytes":89,"name":"manifest.sig","sha256":"0abe27a5b84a6ff2ba58d6c1792052d4722d034200dd3f0e75175ab0fbbc6b8b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b1c797c3a5a892dc27cd7086cce6d2ecf0062ed38c097eeb9174f8f096d65599"}],"publication_id":"OT-2026-000089212"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089212
OpenTechnical

OT-2026-000089212

Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c16ffd6d327c1f5ecdc7d77277cdfdc093a96aafd5a97c02a2ff46e3f2dbe958

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089212, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089212.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089212" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089212" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089212 Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089212 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089212 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089212 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089212", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19042, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ab534aa8dd7230c9e80ccbeac4c89009921915663445f2abe1719a892e3cda35" }, { "bytes": 8544, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8a68db8c95d6d76ef09bbaef3bcaf8a2377737fded41c6a433ce0c17f5c38c49" }, { "bytes": 8200, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c16ffd6d327c1f5ecdc7d77277cdfdc093a96aafd5a97c02a2ff46e3f2dbe958" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089212/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089212", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7df3-a902-43f02f25af43" } tJvkoaoX0YRu+/5uB6wV3zxyt8VDwdxuiZHJlJ/JYXOQteLqwjnzcqmITYlwBLN0ErzYZmqfEvg47V6PEHgfCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: tJvkoaoX0YRu+/5uB6wV3zxyt8VDwdxuiZHJlJ/JYXOQteLqwjnzcqmITYlwBLN0ErzYZmqfEvg47V6PEHgfCQ== {"files":[{"bytes":18484,"name":"index.html","sha256":"89917e59e8d3fb78f310fa00fce6f7dfde87d1ac30f3b4c339cc5c8371f0697f"},{"bytes":8057,"name":"publication.md","sha256":"5f9f339d627c58e0df18fbb06b1ad006da3dcaed0a6793f704690f2425038d78"},{"bytes":7719,"name":"publication.txt","sha256":"42a50fb7b121bba00f45c0f4d635cd7159f78a7fabc3ae46581794426d7ba78e"},{"bytes":2857,"name":"manifest.json","sha256":"9d46dac9971ffb6db808c9603529a371e5f13f8cfd1e377de356bf1d4442fb7f"},{"bytes":89,"name":"manifest.sig","sha256":"78fac5051c48eef2c9f5b687a649fd43030abef4a40bca2305f29feb62f8e91f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f2080dac1c4cb4e7c14db5c7f09578b25c50fb8cd1c2f099c41f7355e4fb8ac7"}],"publication_id":"OT-2026-000089213"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089213
OpenTechnical

OT-2026-000089213

Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
42a50fb7b121bba00f45c0f4d635cd7159f78a7fabc3ae46581794426d7ba78e

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089213, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089213.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089213" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089213" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089213 Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089213 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089213 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089213 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089213", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18484, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "89917e59e8d3fb78f310fa00fce6f7dfde87d1ac30f3b4c339cc5c8371f0697f" }, { "bytes": 8057, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5f9f339d627c58e0df18fbb06b1ad006da3dcaed0a6793f704690f2425038d78" }, { "bytes": 7719, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "42a50fb7b121bba00f45c0f4d635cd7159f78a7fabc3ae46581794426d7ba78e" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089213/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089213", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-75ef-8d3e-cc0ae3da65cf" } ttbYHRZoftKT3YhfeDMUKnnJo0wE8kwcJLHBSZxNNC6ZH+69AslOqRu3cwK2Tq+XVkAzsyjYDRHpceCt0dckAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ttbYHRZoftKT3YhfeDMUKnnJo0wE8kwcJLHBSZxNNC6ZH+69AslOqRu3cwK2Tq+XVkAzsyjYDRHpceCt0dckAw== {"files":[{"bytes":19299,"name":"index.html","sha256":"bcf78d6213f3b13e0e8e43693d664a39e3439a3c114f76d12a5d869beaa26400"},{"bytes":8758,"name":"publication.md","sha256":"d36878c8c804d114a8dc7ab564fd5a6d0a234718bd5a1db6b7c108aef43cfa33"},{"bytes":8414,"name":"publication.txt","sha256":"885ad3e63d5e001915433c700ec368cee443842bce49f608e9c34809b7ed9b48"},{"bytes":2869,"name":"manifest.json","sha256":"bbd871cfbc17b30e0b376c76fc24411631bad1212d25cb182f2512396215c821"},{"bytes":89,"name":"manifest.sig","sha256":"68ae0c6892ade3525d25074fc999a0106f0dda6614cde677ab3b4aee8aa23b40"},{"bytes":227,"name":"manifest.sig.txt","sha256":"acdbf47bcc533a3b7deefb35652851f1e13906410e93b45c63455d8df99ad0d9"}],"publication_id":"OT-2026-000089214"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089214
OpenTechnical

OT-2026-000089214

Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
885ad3e63d5e001915433c700ec368cee443842bce49f608e9c34809b7ed9b48

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089214, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089214.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089214" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089214" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089214 Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089214 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089214 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089214 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089214", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19299, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bcf78d6213f3b13e0e8e43693d664a39e3439a3c114f76d12a5d869beaa26400" }, { "bytes": 8758, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d36878c8c804d114a8dc7ab564fd5a6d0a234718bd5a1db6b7c108aef43cfa33" }, { "bytes": 8414, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "885ad3e63d5e001915433c700ec368cee443842bce49f608e9c34809b7ed9b48" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089214/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089214", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7338-977a-d27e2cfe91db" } Yycuy4Ckf+ttC1G2diEGfO1w2ik+PM7l0haxQpoJ9lTz2oGyV9RjudSYFYJfZGeC9I/bgvkt3ahhBIaSvDf6Cg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Yycuy4Ckf+ttC1G2diEGfO1w2ik+PM7l0haxQpoJ9lTz2oGyV9RjudSYFYJfZGeC9I/bgvkt3ahhBIaSvDf6Cg== {"files":[{"bytes":19046,"name":"index.html","sha256":"47472c0a16ada4d0e3307ee51397706d25db23b5a1701e98d0798f17c189d573"},{"bytes":8548,"name":"publication.md","sha256":"52c1a5ab00ce48768635851e05f1ae88f15f7c1c2d82879513699500536aa0bb"},{"bytes":8204,"name":"publication.txt","sha256":"23a6e53eca9e4d412a443f142863633ab556e767d000eafb8bb7b33242fa4005"},{"bytes":2869,"name":"manifest.json","sha256":"172a317ef0b4b755a336bdd4e4a2a78bf7acf7df37213e21039ebec79011f5c7"},{"bytes":89,"name":"manifest.sig","sha256":"a1cbbb9254eced1fda982fca683a6e13340c4a3cc7ad587e1969ca95169e4ff0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f8c45d82cf0718ea1f4625383564e44f2a1091d58af2dea0864d43f3363aa1e3"}],"publication_id":"OT-2026-000089215"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089215
OpenTechnical

OT-2026-000089215

Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
23a6e53eca9e4d412a443f142863633ab556e767d000eafb8bb7b33242fa4005

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089215, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089215.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089215" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089215" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089215 Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089215 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089215 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089215 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089215", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19046, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "47472c0a16ada4d0e3307ee51397706d25db23b5a1701e98d0798f17c189d573" }, { "bytes": 8548, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "52c1a5ab00ce48768635851e05f1ae88f15f7c1c2d82879513699500536aa0bb" }, { "bytes": 8204, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "23a6e53eca9e4d412a443f142863633ab556e767d000eafb8bb7b33242fa4005" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089215/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089215", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7ff7-b83c-38d63cd080cf" } xdEy0zmuRv6dAplHi535SSgU34uQtOQhwxkSgXsbGT/ORD0iVpebxhim678ycefGz3u/nHidagdVNFQ4Du1GCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: xdEy0zmuRv6dAplHi535SSgU34uQtOQhwxkSgXsbGT/ORD0iVpebxhim678ycefGz3u/nHidagdVNFQ4Du1GCg== {"files":[{"bytes":18665,"name":"index.html","sha256":"8e43458005f526a95d63e51269b4af837d140ceb1a9250d93984a05d06b60278"},{"bytes":8208,"name":"publication.md","sha256":"afc8a66c4c5f72556dc7d64cc70f00222a0a8c5ebbcdc548664fceea3a0f0ce0"},{"bytes":7881,"name":"publication.txt","sha256":"3a706f68d850f652244a62cd7010a4a9e0c2eac837a77735da5467a67e1208c9"},{"bytes":2834,"name":"manifest.json","sha256":"419496aff556d27dd5db2c1869ed6694ef0d0b49e4bee870c263874e5ac9c9a1"},{"bytes":89,"name":"manifest.sig","sha256":"6050c7bd314be3a6d894bcf82e28dcb106debcc19935a3196fa583a68f216965"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3f2cd22a34625e7845b71f2a8f2039250c3bd97c70fb7416dfe021a9a6d32917"}],"publication_id":"OT-2026-000089216"} Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089216
OpenTechnical

OT-2026-000089216

Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
3a706f68d850f652244a62cd7010a4a9e0c2eac837a77735da5467a67e1208c9

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089216, “Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089216.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089216" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089216" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089216 Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089216 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089216 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089216 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089216", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1151 }, "figures": [], "files": [ { "bytes": 18665, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8e43458005f526a95d63e51269b4af837d140ceb1a9250d93984a05d06b60278" }, { "bytes": 8208, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "afc8a66c4c5f72556dc7d64cc70f00222a0a8c5ebbcdc548664fceea3a0f0ce0" }, { "bytes": 7881, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3a706f68d850f652244a62cd7010a4a9e0c2eac837a77735da5467a67e1208c9" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089216/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089216", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-78c2-84cb-a010546c7cf5" } lNq4x4lTH2U5b2YvFouOpM8/2YtH7MuWlhxvq1KPj/ntzsoLffBqUdKLEbIHRDdElPw6dKOLWSEjj7IoOnHbDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: lNq4x4lTH2U5b2YvFouOpM8/2YtH7MuWlhxvq1KPj/ntzsoLffBqUdKLEbIHRDdElPw6dKOLWSEjj7IoOnHbDw== {"files":[{"bytes":19480,"name":"index.html","sha256":"0a1322551cbae3f4e54c4bdae5e178853d3f1dd8b468ce8e3836d2c75432417f"},{"bytes":8909,"name":"publication.md","sha256":"7046b58fb89ba48dcfaf62a86d3bbba6274daa3e62470bf5f2e3ee4aa46d5c97"},{"bytes":8576,"name":"publication.txt","sha256":"680624bf109cd26c637064cbbff227996b1d54399c6c482b92a37ce1ff0581cd"},{"bytes":2846,"name":"manifest.json","sha256":"58e06df2a2c0e66db0a66e64f83bd49e1b5e9486a215fd8b56fe99a5ac07fcc3"},{"bytes":89,"name":"manifest.sig","sha256":"73408cc6fe5b0b3a4a56524b80bc0783ef2ee38940df54ef09e70ca12168e2df"},{"bytes":227,"name":"manifest.sig.txt","sha256":"5fe9e4292b9db8b09a7929ad7fb5ffadcbb493f5f1658dda3f2c483da8b81395"}],"publication_id":"OT-2026-000089217"} Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089217
OpenTechnical

OT-2026-000089217

Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
680624bf109cd26c637064cbbff227996b1d54399c6c482b92a37ce1ff0581cd

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089217, “Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089217.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089217" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089217" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089217 Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089217 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089217 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089217 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089217", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1257 }, "figures": [], "files": [ { "bytes": 19480, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0a1322551cbae3f4e54c4bdae5e178853d3f1dd8b468ce8e3836d2c75432417f" }, { "bytes": 8909, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7046b58fb89ba48dcfaf62a86d3bbba6274daa3e62470bf5f2e3ee4aa46d5c97" }, { "bytes": 8576, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "680624bf109cd26c637064cbbff227996b1d54399c6c482b92a37ce1ff0581cd" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089217/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089217", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-703f-a638-d5b768d9293d" } bU+ZFvGRik+w6+o1EyBh1RvPGAH1ox7Qz38UPlZLQF02ZbFhkFPAUEI6QbtOdhy6FHUnShfWm+gsD47g/JexBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: bU+ZFvGRik+w6+o1EyBh1RvPGAH1ox7Qz38UPlZLQF02ZbFhkFPAUEI6QbtOdhy6FHUnShfWm+gsD47g/JexBA== {"files":[{"bytes":19227,"name":"index.html","sha256":"ee45131c2c1951844e474cf933200b7aca70baff5a2d1d588a3f3a40362b2894"},{"bytes":8699,"name":"publication.md","sha256":"a7010ec9345286d6c8e98157797f5c62ae85cfccace9ca7d3b80a00abb5391e9"},{"bytes":8366,"name":"publication.txt","sha256":"cbce6741e12cdc67be13748b7171c8eb3a6b9b7c2ea365a14fe58b1db117fc2c"},{"bytes":2846,"name":"manifest.json","sha256":"aebbdd8d5735729079e33d8401a061ed597485e131c2f0a49ad5945b6429a06d"},{"bytes":89,"name":"manifest.sig","sha256":"44556ff58ff0ebaa5896f10bd3f7f2153623a44d48a924ecedfa6f2c2527f476"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a2aaa98aacb9c5ecaf1164affd80e73150dd1d8df6c975efa36d0f900d03cd4a"}],"publication_id":"OT-2026-000089218"} Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089218
OpenTechnical

OT-2026-000089218

Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cbce6741e12cdc67be13748b7171c8eb3a6b9b7c2ea365a14fe58b1db117fc2c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089218, “Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089218.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089218" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089218" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089218 Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089218 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089218 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089218 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089218", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1222 }, "figures": [], "files": [ { "bytes": 19227, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ee45131c2c1951844e474cf933200b7aca70baff5a2d1d588a3f3a40362b2894" }, { "bytes": 8699, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a7010ec9345286d6c8e98157797f5c62ae85cfccace9ca7d3b80a00abb5391e9" }, { "bytes": 8366, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cbce6741e12cdc67be13748b7171c8eb3a6b9b7c2ea365a14fe58b1db117fc2c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089218/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089218", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7521-8a40-4dbd8f0ca5e9" } 2/+uMFlXUX+dKuAqgF87s4HaKOW200KjR7+RU/7rXLIafwtUz6rPnqum9YGKhGe3rNyd3EbaZis7lXV2goKNAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 2/+uMFlXUX+dKuAqgF87s4HaKOW200KjR7+RU/7rXLIafwtUz6rPnqum9YGKhGe3rNyd3EbaZis7lXV2goKNAQ== {"files":[{"bytes":18611,"name":"index.html","sha256":"5480291a0bde3394a2116f3c4a2e606fd8f06cda0301a964ab34d01e97d9b0b9"},{"bytes":8154,"name":"publication.md","sha256":"c1a28e42cd0034c3230d7ad1f99685f98172c457169dab1039b7847078103d72"},{"bytes":7827,"name":"publication.txt","sha256":"6d44161149773585d749fc7adee9afaa9ccdd60b2f048cb038b087d494618285"},{"bytes":2834,"name":"manifest.json","sha256":"279d477139289b8a51c73f2f302b6edb5112881f745d6f31af0332424bc81465"},{"bytes":89,"name":"manifest.sig","sha256":"b297286568d6be447738a416fdd93fdb0cdf6744823da2d5462c5ae6b114cbe4"},{"bytes":227,"name":"manifest.sig.txt","sha256":"000346492f8a1eae37f81400b941175e0ec968541afe1c43206cc21db997ff81"}],"publication_id":"OT-2026-000089219"} Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089219
OpenTechnical

OT-2026-000089219

Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
6d44161149773585d749fc7adee9afaa9ccdd60b2f048cb038b087d494618285

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089219, “Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089219.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089219" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089219" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089219 Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089219 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089219 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089219 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089219", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1136 }, "figures": [], "files": [ { "bytes": 18611, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5480291a0bde3394a2116f3c4a2e606fd8f06cda0301a964ab34d01e97d9b0b9" }, { "bytes": 8154, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c1a28e42cd0034c3230d7ad1f99685f98172c457169dab1039b7847078103d72" }, { "bytes": 7827, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "6d44161149773585d749fc7adee9afaa9ccdd60b2f048cb038b087d494618285" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089219/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089219", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7cf2-ac43-5750c405c235" } i8yvGtzJCWGN8vtMxk7l3qitQatxHzINy9FqzhUrjTPLy3xadVsP5IlCbWrnbBp9kMCwGn6okpUyz8utuQToBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: i8yvGtzJCWGN8vtMxk7l3qitQatxHzINy9FqzhUrjTPLy3xadVsP5IlCbWrnbBp9kMCwGn6okpUyz8utuQToBw== {"files":[{"bytes":19426,"name":"index.html","sha256":"8d2f86542971fba06b7bc04cee249e3fa27e426fd1c6af4614d567867470ab9a"},{"bytes":8855,"name":"publication.md","sha256":"28d758460bc27a9561b3c686e2d4a0fd2965b90f5ab43d450974fcaa8ef1a240"},{"bytes":8522,"name":"publication.txt","sha256":"5fd67657bcc9670e6c3c3b368c0d22d65563c2bceee114cc1e592e2bf45401f7"},{"bytes":2846,"name":"manifest.json","sha256":"73ad28519e89153041801b005d0568cfd5587552b1c8969422d73f826d2e72d4"},{"bytes":89,"name":"manifest.sig","sha256":"844be67b7e1cd6d8caa166836b16b69e48b3ae68599b3b44226a4172e3ef2c7e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"36cc9b12034caa29ca8373f207fbdbf7abdf7358d05acd253c01ca641a101125"}],"publication_id":"OT-2026-000089220"} Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089220
OpenTechnical

OT-2026-000089220

Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
5fd67657bcc9670e6c3c3b368c0d22d65563c2bceee114cc1e592e2bf45401f7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089220, “Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089220.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089220" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089220" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089220 Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089220 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089220 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089220 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089220", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1242 }, "figures": [], "files": [ { "bytes": 19426, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8d2f86542971fba06b7bc04cee249e3fa27e426fd1c6af4614d567867470ab9a" }, { "bytes": 8855, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "28d758460bc27a9561b3c686e2d4a0fd2965b90f5ab43d450974fcaa8ef1a240" }, { "bytes": 8522, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5fd67657bcc9670e6c3c3b368c0d22d65563c2bceee114cc1e592e2bf45401f7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089220/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089220", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-702f-b51e-879dfddc835b" } 7HBkSIwA9AkCNdmc803ct2zZSGVXRpzJP+kadfU6RwyGTqyixGJBU//I6UiwkK5bZy+3xV4+M52+fmQ2uDVBBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 7HBkSIwA9AkCNdmc803ct2zZSGVXRpzJP+kadfU6RwyGTqyixGJBU//I6UiwkK5bZy+3xV4+M52+fmQ2uDVBBw== {"files":[{"bytes":19173,"name":"index.html","sha256":"9f0c4853fd6358b35a92b7d0c2daed1506a577c60015717a1aadfe8be2f63bf9"},{"bytes":8645,"name":"publication.md","sha256":"14a7e41d75252b4eb465139429d9ba6d5f35082346516b5cd4f5a42170363d0e"},{"bytes":8312,"name":"publication.txt","sha256":"02993629b2db2a52fc2eeb1878c92980ca9afe8934a57bbb1d18141c3d37d825"},{"bytes":2846,"name":"manifest.json","sha256":"5393553e72f193b67466596445386206bcc6224eaf4b44c4b1a96b9fb031dce2"},{"bytes":89,"name":"manifest.sig","sha256":"a0daeaf76a127380ef3434212e8a070892b357849102cb6c938ffae6b6a38d63"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3a06d791eb2c1678582625905137ad62055df7b230531223e91e17744d97212b"}],"publication_id":"OT-2026-000089221"} Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089221
OpenTechnical

OT-2026-000089221

Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
02993629b2db2a52fc2eeb1878c92980ca9afe8934a57bbb1d18141c3d37d825

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089221, “Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089221.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089221" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089221" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089221 Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089221 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089221 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089221 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089221", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1207 }, "figures": [], "files": [ { "bytes": 19173, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9f0c4853fd6358b35a92b7d0c2daed1506a577c60015717a1aadfe8be2f63bf9" }, { "bytes": 8645, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "14a7e41d75252b4eb465139429d9ba6d5f35082346516b5cd4f5a42170363d0e" }, { "bytes": 8312, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "02993629b2db2a52fc2eeb1878c92980ca9afe8934a57bbb1d18141c3d37d825" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089221/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089221", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7f11-8b4a-0bf5eb87a848" } L0zMLi3R3BZqYOXdWmi3HPb0LYwe101WF7Im0mmnr4CK0gmxQHF2OO5RPqEb91nTWnj2A8y5iY8TuiA2tJNpBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: L0zMLi3R3BZqYOXdWmi3HPb0LYwe101WF7Im0mmnr4CK0gmxQHF2OO5RPqEb91nTWnj2A8y5iY8TuiA2tJNpBg== {"files":[{"bytes":18373,"name":"index.html","sha256":"fe30b04a91704eb6256989cf79690301de0778522b77d46406907ea37e242feb"},{"bytes":7962,"name":"publication.md","sha256":"514cab9942e788e010bf8e2f679ab0e919e6c9b4fdc812705bb60a25dbd491a0"},{"bytes":7632,"name":"publication.txt","sha256":"589bd37339eb335378b8af453af47fafa5eeaaffe3412418ef74ef01122f55dd"},{"bytes":2849,"name":"manifest.json","sha256":"bf486f1cfff11fb6e24edc0873ae991c6d0fee259faa731b68aae792bfdb66b8"},{"bytes":89,"name":"manifest.sig","sha256":"4d6ad11b74c90bb79f41cad4ecae0d5a0156754cf11fe5aaecf9075c0ac745f7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b6103ef1104f1e9d1f8abcc9d8fa46b66cc252811185b0c1fae99bcf8d0f57a3"}],"publication_id":"OT-2026-000089222"} Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089222
OpenTechnical

OT-2026-000089222

Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
589bd37339eb335378b8af453af47fafa5eeaaffe3412418ef74ef01122f55dd

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089222, “Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089222.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089222" title: "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089222" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089222 Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089222 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089222 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089222 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089222", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18373, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "fe30b04a91704eb6256989cf79690301de0778522b77d46406907ea37e242feb" }, { "bytes": 7962, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "514cab9942e788e010bf8e2f679ab0e919e6c9b4fdc812705bb60a25dbd491a0" }, { "bytes": 7632, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "589bd37339eb335378b8af453af47fafa5eeaaffe3412418ef74ef01122f55dd" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089222/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089222", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-78ff-b959-d07d0254eb81" } UKQmYd1lABQfYiPBvEcO/+isnmOasSVZob0zBJZbra0yYE4gQtY69aidbwZFElCbsK4E8Ybc4If6Wl078H93DA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: UKQmYd1lABQfYiPBvEcO/+isnmOasSVZob0zBJZbra0yYE4gQtY69aidbwZFElCbsK4E8Ybc4If6Wl078H93DA== {"files":[{"bytes":19188,"name":"index.html","sha256":"931a3997ff26c9d04f472098690f929bdfe05b7f336a51425e8ce3beffb4d9bf"},{"bytes":8663,"name":"publication.md","sha256":"6b516117cda579aea6abeccd1cb9d55e2aa2b4f6bee51456eb029b06a2ea5d4d"},{"bytes":8327,"name":"publication.txt","sha256":"88890c08416b21e766979bb20909993c1bc8475b2260395575af14ee4449a7d5"},{"bytes":2861,"name":"manifest.json","sha256":"a48bdd4c1437601cfcad38cbc5557669963e64db4e34f87d4bfe92b6f7947586"},{"bytes":89,"name":"manifest.sig","sha256":"c1742b82b7563e23fdc697dc15fb5aecb2da742fcc4ca8f8f12e1678b3a501e4"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3e3a7237e67833108b1ea8d11b99b8403ac88ac1cbe174e3e048c0198753a195"}],"publication_id":"OT-2026-000089223"} Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089223
OpenTechnical

OT-2026-000089223

Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
88890c08416b21e766979bb20909993c1bc8475b2260395575af14ee4449a7d5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089223, “Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089223.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089223" title: "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089223" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089223 Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089223 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089223 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089223 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089223", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19188, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "931a3997ff26c9d04f472098690f929bdfe05b7f336a51425e8ce3beffb4d9bf" }, { "bytes": 8663, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "6b516117cda579aea6abeccd1cb9d55e2aa2b4f6bee51456eb029b06a2ea5d4d" }, { "bytes": 8327, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "88890c08416b21e766979bb20909993c1bc8475b2260395575af14ee4449a7d5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089223/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089223", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7dd3-99b4-4d546e9f3b07" } imShGrnX6FOMZ4q+PO7qPNtvDNX5tO6ZBTsqtllH1GRhNJlYF8njRAvYvpp9JXtF2Y+4TxVTPqD2XsiaI8kXCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: imShGrnX6FOMZ4q+PO7qPNtvDNX5tO6ZBTsqtllH1GRhNJlYF8njRAvYvpp9JXtF2Y+4TxVTPqD2XsiaI8kXCA== {"files":[{"bytes":18935,"name":"index.html","sha256":"0069e7a59e13a61571e9bd3d0eb7db8c4e5b9863636511ad66ec90a2df4b10e7"},{"bytes":8453,"name":"publication.md","sha256":"f0d360939bf4bc0feebcefc8c71eb3c7186a451ae69e0b1a5b8aa1d5239e2700"},{"bytes":8117,"name":"publication.txt","sha256":"69c6fa56efc2c24c21ee4ec7e37f4bc7062fb004b52a7d14207e62a11370fa76"},{"bytes":2861,"name":"manifest.json","sha256":"9a43543bf3bc20b560da9c0171cc5685d080f2063a8a5e9560b7dac377faaed1"},{"bytes":89,"name":"manifest.sig","sha256":"f7b225a2bf021054ce2d54a586f17ade6313d4c2ef89d833638055009ce85e83"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2db8af6479ff1d3aa81bdc9db93cfa839e7ca6a925da42a92370bc8ab9161404"}],"publication_id":"OT-2026-000089224"} Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089224
OpenTechnical

OT-2026-000089224

Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
69c6fa56efc2c24c21ee4ec7e37f4bc7062fb004b52a7d14207e62a11370fa76

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089224, “Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089224.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089224" title: "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089224" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089224 Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089224 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089224 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089224 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089224", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18935, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0069e7a59e13a61571e9bd3d0eb7db8c4e5b9863636511ad66ec90a2df4b10e7" }, { "bytes": 8453, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f0d360939bf4bc0feebcefc8c71eb3c7186a451ae69e0b1a5b8aa1d5239e2700" }, { "bytes": 8117, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "69c6fa56efc2c24c21ee4ec7e37f4bc7062fb004b52a7d14207e62a11370fa76" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089224/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089224", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7192-8a9e-0c65c53afed7" } CYQhlK14ooWG6YtVrJEaIjq/yRaR9bN08S6xu4hLIkRCIOeQy5GhXNSBwdzC4o5MeaJ2qBt3036b8cwUb1uoDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: CYQhlK14ooWG6YtVrJEaIjq/yRaR9bN08S6xu4hLIkRCIOeQy5GhXNSBwdzC4o5MeaJ2qBt3036b8cwUb1uoDQ== {"files":[{"bytes":18373,"name":"index.html","sha256":"6fdfaac0d3d51e8eb1d80c5b39785048ab9a835bc52d8c6a605c59e5ecb008af"},{"bytes":7962,"name":"publication.md","sha256":"a2eb44953a748a82421c2effd253f2e0b186cd63bebf73124d9eca45cbfd21aa"},{"bytes":7632,"name":"publication.txt","sha256":"93664092a1e0e8a3e48cccef1b572a6a74ee02b20049ef94f7b6b303169c101f"},{"bytes":2849,"name":"manifest.json","sha256":"180d735b635c342491c31235529f1ada7ec5cfeb12b2917e0942f890f1a9276f"},{"bytes":89,"name":"manifest.sig","sha256":"52c35ceef164060641964897896e08ec0220ac3d7faf98ecb25d0005d80fd67a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1f14a99d7f4c0b08f6a2d6acb7083aed59b358ceddbf3eb99bca89465d8f4825"}],"publication_id":"OT-2026-000089225"} Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089225
OpenTechnical

OT-2026-000089225

Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
93664092a1e0e8a3e48cccef1b572a6a74ee02b20049ef94f7b6b303169c101f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089225, “Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089225.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089225" title: "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089225" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089225 Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089225 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089225 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089225 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089225", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18373, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6fdfaac0d3d51e8eb1d80c5b39785048ab9a835bc52d8c6a605c59e5ecb008af" }, { "bytes": 7962, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a2eb44953a748a82421c2effd253f2e0b186cd63bebf73124d9eca45cbfd21aa" }, { "bytes": 7632, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "93664092a1e0e8a3e48cccef1b572a6a74ee02b20049ef94f7b6b303169c101f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089225/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089225", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-72ea-9fb7-5f38f111a9ee" } qr09ZY770zLWA2qLB1voNPPNi3S9/dQctWurErIN+ID1acpn3wsmprV4rzt3aQnSJ2N0ChXiS5xKuubAEfMICQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: qr09ZY770zLWA2qLB1voNPPNi3S9/dQctWurErIN+ID1acpn3wsmprV4rzt3aQnSJ2N0ChXiS5xKuubAEfMICQ== {"files":[{"bytes":19188,"name":"index.html","sha256":"10962c66bd324cbb5d9d5f8a9dcb9b99c683d7a4d8644174025e1fcd1058f54e"},{"bytes":8663,"name":"publication.md","sha256":"70a4dbb889db93fe9032c33dba77a05c97ce6fd629081a0a841ed4863cf48323"},{"bytes":8327,"name":"publication.txt","sha256":"fa223c8eca443a46a26eb04458b0e679415966bd753a42abe2e16c2db37b729d"},{"bytes":2861,"name":"manifest.json","sha256":"b8cf89c7143c82d6e7e038bd8875ad5f805d5d25e370c6db82fa536e3fe0efb6"},{"bytes":89,"name":"manifest.sig","sha256":"46585d3549641394e18d163e9d92ebfccd4d9c8ec99961603835b610a4b0b0d5"},{"bytes":227,"name":"manifest.sig.txt","sha256":"48ada4f23d14743b6c21c76b247d2ad7ed0b02acb264391e6e8b4de27234fdf6"}],"publication_id":"OT-2026-000089226"} Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089226
OpenTechnical

OT-2026-000089226

Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
fa223c8eca443a46a26eb04458b0e679415966bd753a42abe2e16c2db37b729d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089226, “Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089226.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089226" title: "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089226" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089226 Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089226 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089226 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089226 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089226", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19188, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "10962c66bd324cbb5d9d5f8a9dcb9b99c683d7a4d8644174025e1fcd1058f54e" }, { "bytes": 8663, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "70a4dbb889db93fe9032c33dba77a05c97ce6fd629081a0a841ed4863cf48323" }, { "bytes": 8327, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fa223c8eca443a46a26eb04458b0e679415966bd753a42abe2e16c2db37b729d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089226/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089226", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-748a-b2d1-5de0b11fb7c7" } RCk21fNGLEz/8VMP7GMjozbeRrUK6m7Hodc4oc2a2E0Stry8R4jgzWw6RGKcUQJeWDPKUqcimx4h+4qPY7LkAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: RCk21fNGLEz/8VMP7GMjozbeRrUK6m7Hodc4oc2a2E0Stry8R4jgzWw6RGKcUQJeWDPKUqcimx4h+4qPY7LkAQ== {"files":[{"bytes":18935,"name":"index.html","sha256":"7eb8327c42226a68a0633dadaf8f867dbaeed18da256d728f1b1a275462d6ff5"},{"bytes":8453,"name":"publication.md","sha256":"971dc22b353f2b7e1dddda8fbcf73c9d6e64de0a57f002dc56c33cc640dbf89d"},{"bytes":8117,"name":"publication.txt","sha256":"e283b1648dc7ac626f440c74dcf8f14a7d9188440980e0f4f13dc3f069c3ecee"},{"bytes":2861,"name":"manifest.json","sha256":"840e26d94f885afcc0e4ec9cb6b43ef47287f6d10343a61dc4bbe3db41f158b5"},{"bytes":89,"name":"manifest.sig","sha256":"5ebb25c1f55a1e1b1cdbf8b26e24d60bf83e96749bd466175cbab8ccdb5f6685"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4abeef550072511c6a116363d7065fd46e43e54932853e90ff0a626f5274de90"}],"publication_id":"OT-2026-000089227"} Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089227
OpenTechnical

OT-2026-000089227

Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e283b1648dc7ac626f440c74dcf8f14a7d9188440980e0f4f13dc3f069c3ecee

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089227, “Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089227.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089227" title: "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089227" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089227 Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089227 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089227 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089227 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089227", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18935, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7eb8327c42226a68a0633dadaf8f867dbaeed18da256d728f1b1a275462d6ff5" }, { "bytes": 8453, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "971dc22b353f2b7e1dddda8fbcf73c9d6e64de0a57f002dc56c33cc640dbf89d" }, { "bytes": 8117, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e283b1648dc7ac626f440c74dcf8f14a7d9188440980e0f4f13dc3f069c3ecee" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089227/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089227", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, two stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-760a-9019-26f16c130fcf" } 9rF1FFAxbPRQ0iI6CFfP1894GRfhnYDSeSibA3cLkIfWtIbi44Gsu+ii3ePtxgeYFA5UrlRQDiQlM1A9g5PwAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 9rF1FFAxbPRQ0iI6CFfP1894GRfhnYDSeSibA3cLkIfWtIbi44Gsu+ii3ePtxgeYFA5UrlRQDiQlM1A9g5PwAQ== {"files":[{"bytes":18491,"name":"index.html","sha256":"945639791c22f78eeb51a5684fdbd7c32e2269fbeb3d2e70aadae5c14e3e2c94"},{"bytes":8060,"name":"publication.md","sha256":"08e825688c557020ec2bb44d07048671cab1d98b3e728407611fc9d9696afb09"},{"bytes":7720,"name":"publication.txt","sha256":"7a00596741d6b9eeb1e273c27a8e0e8b777380d7f1f970fa89e7b2e74cbefddf"},{"bytes":2859,"name":"manifest.json","sha256":"b3e9143b0f988238339fff3f6903a66edd29a740af5c43e5968803b2bb8c2bc2"},{"bytes":89,"name":"manifest.sig","sha256":"de061a96fb7b712f8e60e504fc300758c31adcd3880387815a25e3bda9088e8a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"91b06d2d283473c0b94fea931954430879c79c2b6dea22083d9ee28a895ef935"}],"publication_id":"OT-2026-000089228"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089228
OpenTechnical

OT-2026-000089228

Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
7a00596741d6b9eeb1e273c27a8e0e8b777380d7f1f970fa89e7b2e74cbefddf

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089228, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089228.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089228" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089228" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089228 Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089228 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089228 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089228 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089228", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18491, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "945639791c22f78eeb51a5684fdbd7c32e2269fbeb3d2e70aadae5c14e3e2c94" }, { "bytes": 8060, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "08e825688c557020ec2bb44d07048671cab1d98b3e728407611fc9d9696afb09" }, { "bytes": 7720, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7a00596741d6b9eeb1e273c27a8e0e8b777380d7f1f970fa89e7b2e74cbefddf" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089228/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089228", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7ec1-84be-8f49ace39d0b" } nIWCheOZD1y39+a0OEiqFgg7wNjufBJxS+b15OPIY6OKUqXEQ2McAq10tDAv3XgQsztMETpNGkBY9RTl2CBGBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: nIWCheOZD1y39+a0OEiqFgg7wNjufBJxS+b15OPIY6OKUqXEQ2McAq10tDAv3XgQsztMETpNGkBY9RTl2CBGBg== {"files":[{"bytes":19306,"name":"index.html","sha256":"c7aee94ab3c9cc271d89aa84855283a40509205c5029b5411a993552b29a2e05"},{"bytes":8761,"name":"publication.md","sha256":"5201cec47104905592622c7aab38a43520706849a468afbc79a45f7e2a260312"},{"bytes":8415,"name":"publication.txt","sha256":"906a6626e6a8aa3800d270fe376a84e4dd695b38758f1208305286f7238447ae"},{"bytes":2871,"name":"manifest.json","sha256":"584598e7be1c0c2778e4bbe240bbd3e6944f32b7b6b661760813ce44452db6cf"},{"bytes":89,"name":"manifest.sig","sha256":"a0b13706084d699ce1bca755133022dea3c1d332166dcabd4f236234db902ed8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ba79420e5bdb330fe54b381368b2a9cb06088a4a48423980372ce3b98c348b76"}],"publication_id":"OT-2026-000089229"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089229
OpenTechnical

OT-2026-000089229

Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
906a6626e6a8aa3800d270fe376a84e4dd695b38758f1208305286f7238447ae

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089229, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089229.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089229" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089229" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089229 Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089229 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089229 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089229 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089229", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19306, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c7aee94ab3c9cc271d89aa84855283a40509205c5029b5411a993552b29a2e05" }, { "bytes": 8761, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5201cec47104905592622c7aab38a43520706849a468afbc79a45f7e2a260312" }, { "bytes": 8415, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "906a6626e6a8aa3800d270fe376a84e4dd695b38758f1208305286f7238447ae" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089229/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089229", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7dbf-8744-143513f90024" } j0icM3QB9ARpkQx/RGclb6W4uz4P0Al3tlTbRRC7ib5lYHSiBHCPoxgD8DKB1LL/+nwbGea30dj4ADoeyYKhDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: j0icM3QB9ARpkQx/RGclb6W4uz4P0Al3tlTbRRC7ib5lYHSiBHCPoxgD8DKB1LL/+nwbGea30dj4ADoeyYKhDA== {"files":[{"bytes":19053,"name":"index.html","sha256":"2c54ef01531fad25aecc8de30d370c84cfc6f8b9ae265d593316602d27918f66"},{"bytes":8551,"name":"publication.md","sha256":"75f06618bba1a036f252cf2280ca0229b8782a9b41aa2f6ce79a8c8c5f1311c6"},{"bytes":8205,"name":"publication.txt","sha256":"0e234ceba05d91cdf3dc3cc1b4e6d5e90822e7bd6025503c857216309e4a626c"},{"bytes":2871,"name":"manifest.json","sha256":"3500cd934601e628151c3ff09a171b88fc4f41e05bb6dfa66a9cfbb70f4cb70e"},{"bytes":89,"name":"manifest.sig","sha256":"59f9a490993f49ffd6f5a12eebda54c62c3b573b5950128501ef0b1e3aa23d4c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a6420e6661ed3ed179fa0dcf6a1225fbdf02e30f2e77d2d172279adccc801832"}],"publication_id":"OT-2026-000089230"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089230
OpenTechnical

OT-2026-000089230

Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
0e234ceba05d91cdf3dc3cc1b4e6d5e90822e7bd6025503c857216309e4a626c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089230, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089230.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089230" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089230" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089230 Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089230 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089230 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089230 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089230", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19053, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2c54ef01531fad25aecc8de30d370c84cfc6f8b9ae265d593316602d27918f66" }, { "bytes": 8551, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "75f06618bba1a036f252cf2280ca0229b8782a9b41aa2f6ce79a8c8c5f1311c6" }, { "bytes": 8205, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0e234ceba05d91cdf3dc3cc1b4e6d5e90822e7bd6025503c857216309e4a626c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089230/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089230", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7d1f-bbfb-52c34d7c5218" } U/6eiPiPfeeEt1Gnj+EyD+ODulbYj9TVGeNaYBTTJqLCYYy35yzlYBqvVkUjEXuATDSK/41em66+L3rVdtrsAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: U/6eiPiPfeeEt1Gnj+EyD+ODulbYj9TVGeNaYBTTJqLCYYy35yzlYBqvVkUjEXuATDSK/41em66+L3rVdtrsAQ== {"files":[{"bytes":18492,"name":"index.html","sha256":"c8e8e16178b96246e062118a13c8b305c0831be09c76e9e6f3403ac20ae018f4"},{"bytes":8061,"name":"publication.md","sha256":"24493d72515caa504126eb3d66b9311459061e639194c12ab84c201c28eb2c0d"},{"bytes":7721,"name":"publication.txt","sha256":"bc89c480bdbf0e05a39d7339dbfaa815b2cd83f5c92ac6bd2de27f51f36ecf97"},{"bytes":2859,"name":"manifest.json","sha256":"3df93910d7e946f6c94073844f4befb8f96f85ea469e98afb030586c5f2e49a8"},{"bytes":89,"name":"manifest.sig","sha256":"22d53754c2f26a04827cd1ae1db3376bfd51ce4fa9a3a87085dbb1bd8df281c0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"435e1a4642e4929a3cd2446ff4491c2573d9b01d74dc991bddfeb9f627ef8921"}],"publication_id":"OT-2026-000089231"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089231
OpenTechnical

OT-2026-000089231

Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
bc89c480bdbf0e05a39d7339dbfaa815b2cd83f5c92ac6bd2de27f51f36ecf97

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089231, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089231.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089231" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089231" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089231 Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089231 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089231 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089231 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089231", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18492, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c8e8e16178b96246e062118a13c8b305c0831be09c76e9e6f3403ac20ae018f4" }, { "bytes": 8061, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "24493d72515caa504126eb3d66b9311459061e639194c12ab84c201c28eb2c0d" }, { "bytes": 7721, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "bc89c480bdbf0e05a39d7339dbfaa815b2cd83f5c92ac6bd2de27f51f36ecf97" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089231/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089231", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7a4a-9c15-a4b4ac480caa" } irxRB9k95OSK3O7GC6dE4ielzFJ8eafuy88qekR4O9EpJe6LBx/qrRnV8X0Ov4ocyKnljq9XJpLoEK2NIzkYDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: irxRB9k95OSK3O7GC6dE4ielzFJ8eafuy88qekR4O9EpJe6LBx/qrRnV8X0Ov4ocyKnljq9XJpLoEK2NIzkYDA== {"files":[{"bytes":19307,"name":"index.html","sha256":"0dc4e0ba401fc8119f6f1a36c5521cdfedab549b5d790bf3d317e4156655c98b"},{"bytes":8762,"name":"publication.md","sha256":"00d2ee7f46715c7fd30e805802728f3b688b546c03465cea98b87dc6f75ac5a4"},{"bytes":8416,"name":"publication.txt","sha256":"2dabc53a0613fac5e98d37f7ec3a0f38e69418b485f29de9bfce251c55d8be2d"},{"bytes":2871,"name":"manifest.json","sha256":"ed1dd47e79831832922088c535e6d29d3da419588ca9896c7c2d648eeb81a6da"},{"bytes":89,"name":"manifest.sig","sha256":"fbfdd2fdb7213448c964b548af666c1e0e7924a97741bb4217ba36ede5fb5a67"},{"bytes":227,"name":"manifest.sig.txt","sha256":"6e9c1663a4806287a04387e2fa05570916926bc9351c20a162565ffd91a64012"}],"publication_id":"OT-2026-000089232"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089232
OpenTechnical

OT-2026-000089232

Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
2dabc53a0613fac5e98d37f7ec3a0f38e69418b485f29de9bfce251c55d8be2d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089232, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089232.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089232" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089232" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089232 Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089232 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089232 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089232 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089232", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19307, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0dc4e0ba401fc8119f6f1a36c5521cdfedab549b5d790bf3d317e4156655c98b" }, { "bytes": 8762, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "00d2ee7f46715c7fd30e805802728f3b688b546c03465cea98b87dc6f75ac5a4" }, { "bytes": 8416, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2dabc53a0613fac5e98d37f7ec3a0f38e69418b485f29de9bfce251c55d8be2d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089232/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089232", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7047-9be8-d825d8b970bf" } 2wsX7WYERgAHKfKlrLvBX+nAqJiQKeSq+HZAaMGAW4jyz7F0gOj8Df1m09luNtvjCwk8/sqmKOF7NrKzBur7DA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 2wsX7WYERgAHKfKlrLvBX+nAqJiQKeSq+HZAaMGAW4jyz7F0gOj8Df1m09luNtvjCwk8/sqmKOF7NrKzBur7DA== {"files":[{"bytes":19054,"name":"index.html","sha256":"b069014323a717fc10633385d551e11e7a5523c6523238b5a8635cd2196ecdef"},{"bytes":8552,"name":"publication.md","sha256":"fd92ddeb6a728fb37edd909be16add39a6ec6fa7062e6d1e7d800ade40ec37c3"},{"bytes":8206,"name":"publication.txt","sha256":"201b8bd15975e2e52a6a74691dbaa8653edad4b21744258e5d0c9ff08759fb3f"},{"bytes":2871,"name":"manifest.json","sha256":"dc42601d92cbcc75a2adaa75305d4f7e5185a9d15222ebb14a207ad4e955007f"},{"bytes":89,"name":"manifest.sig","sha256":"a15cbeda580ad3655a862f9dab00d40854790d42f63ef5a625472fbae696c36d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ad9b64697f1c0fc01eb90687d332804a4a5317353035c462fa192f10cf164e50"}],"publication_id":"OT-2026-000089233"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089233
OpenTechnical

OT-2026-000089233

Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
201b8bd15975e2e52a6a74691dbaa8653edad4b21744258e5d0c9ff08759fb3f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089233, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089233.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089233" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089233" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089233 Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089233 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089233 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089233 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089233", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19054, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b069014323a717fc10633385d551e11e7a5523c6523238b5a8635cd2196ecdef" }, { "bytes": 8552, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fd92ddeb6a728fb37edd909be16add39a6ec6fa7062e6d1e7d800ade40ec37c3" }, { "bytes": 8206, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "201b8bd15975e2e52a6a74691dbaa8653edad4b21744258e5d0c9ff08759fb3f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089233/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089233", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7def-a756-23a88ce38163" } iZjpqnefge2sGi8UXrt83KQMldX0NYqiPCRji3gVFH2KuQ1PQodWl5uMI4v3crh/iykaBpCqKcTzcGQAySz9BA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: iZjpqnefge2sGi8UXrt83KQMldX0NYqiPCRji3gVFH2KuQ1PQodWl5uMI4v3crh/iykaBpCqKcTzcGQAySz9BA== {"files":[{"bytes":18496,"name":"index.html","sha256":"72d065c41cc8d5979cd870a6201cbd7b87d8734b430b3fe9baf109f309c9dd76"},{"bytes":8065,"name":"publication.md","sha256":"8f1d61857312f8487491ad71def9c6332fc4997315643675f732dce446ec0abc"},{"bytes":7725,"name":"publication.txt","sha256":"743f8fd23a808fe87b07223f6e3d75dfc825bb155666d3a83175decf833b57b5"},{"bytes":2859,"name":"manifest.json","sha256":"8c26f0fe6f43471c9a41af4263e61dec98eec30361ecab7329657ac0811084f2"},{"bytes":89,"name":"manifest.sig","sha256":"032fd5e3fe381fc03b768822d54a91b89a30eb3a2b869d17322b2e95f5534478"},{"bytes":227,"name":"manifest.sig.txt","sha256":"de70a04d11ea6bf6dd93e1e16909b28a7f912f3083e44aa8a9f1acb828b249e4"}],"publication_id":"OT-2026-000089234"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089234
OpenTechnical

OT-2026-000089234

Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
743f8fd23a808fe87b07223f6e3d75dfc825bb155666d3a83175decf833b57b5

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089234, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089234.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089234" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089234" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089234 Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089234 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089234 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089234 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089234", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1111 }, "figures": [], "files": [ { "bytes": 18496, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "72d065c41cc8d5979cd870a6201cbd7b87d8734b430b3fe9baf109f309c9dd76" }, { "bytes": 8065, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8f1d61857312f8487491ad71def9c6332fc4997315643675f732dce446ec0abc" }, { "bytes": 7725, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "743f8fd23a808fe87b07223f6e3d75dfc825bb155666d3a83175decf833b57b5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089234/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089234", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-73e2-b4d1-9200ae350924" } NLhKOx0YbUq4EdtFivCB62K7FFY1PTRisXYFXtxOegjeWnCpqdXKvhvBjgJYqhXSkjh9n1CXEnkVm/pgwLzfDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: NLhKOx0YbUq4EdtFivCB62K7FFY1PTRisXYFXtxOegjeWnCpqdXKvhvBjgJYqhXSkjh9n1CXEnkVm/pgwLzfDg== {"files":[{"bytes":19311,"name":"index.html","sha256":"c0c88c5476bb4c4bc3b74ed0ce89973167103d805a65f3094a1d9920ec376fef"},{"bytes":8766,"name":"publication.md","sha256":"60bfab16890482e46d6667ec51e3cb5ff3c9b313f129ebdacff10a7e311197fe"},{"bytes":8420,"name":"publication.txt","sha256":"f4d7d34f8569cdb9ac2440469bbe2482e3a54f5afe6d57d0c892a1905f9ae041"},{"bytes":2871,"name":"manifest.json","sha256":"9dda7ae44c8b6842696cecf7e9dc6dd16d57c02693e12bf05dcf926d264278e1"},{"bytes":89,"name":"manifest.sig","sha256":"60a5d009ddf6a1d2c34d5dc45f03b942a7c64fe2e003e6270e5a5d17f0543bdc"},{"bytes":227,"name":"manifest.sig.txt","sha256":"09f2e3148ed6651aad40537ffddce96bd214bbe544c562c8efa7ede19a53c2a8"}],"publication_id":"OT-2026-000089235"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089235
OpenTechnical

OT-2026-000089235

Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f4d7d34f8569cdb9ac2440469bbe2482e3a54f5afe6d57d0c892a1905f9ae041

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089235, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089235.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089235" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089235" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089235 Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089235 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089235 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089235 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089235", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1217 }, "figures": [], "files": [ { "bytes": 19311, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c0c88c5476bb4c4bc3b74ed0ce89973167103d805a65f3094a1d9920ec376fef" }, { "bytes": 8766, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "60bfab16890482e46d6667ec51e3cb5ff3c9b313f129ebdacff10a7e311197fe" }, { "bytes": 8420, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f4d7d34f8569cdb9ac2440469bbe2482e3a54f5afe6d57d0c892a1905f9ae041" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089235/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089235", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7def-9a01-b0a523f59876" } u1D8JvDB4t0DDztmBLd57U0LIHtC3ST/1fXkvaPEwP5E0E1QtepBDYCLf8TnPMJpXz7wiDSRcAzHcq2t6HB+Cg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: u1D8JvDB4t0DDztmBLd57U0LIHtC3ST/1fXkvaPEwP5E0E1QtepBDYCLf8TnPMJpXz7wiDSRcAzHcq2t6HB+Cg== {"files":[{"bytes":19058,"name":"index.html","sha256":"afbc74e30ad7ff5088906d322d4a4fa1cc7800b598439fc1cc69fe266319484b"},{"bytes":8556,"name":"publication.md","sha256":"5b52404e017d7d7b98372b2c0378bad83ba3caded9e445b802362f6b8de1f983"},{"bytes":8210,"name":"publication.txt","sha256":"4fcf6542fc50e31ab77bca47689f30c62e7ae1251b95386cb55f5e7c16ff5a86"},{"bytes":2871,"name":"manifest.json","sha256":"ba89d449ce8394813e3dee550a5172c218dd6cae7b9d904532576257e4d10024"},{"bytes":89,"name":"manifest.sig","sha256":"4b5036300bc10a7f6e8955347a1840b13ab7d0118c07256d789186773802b544"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d1fb03905b3b6d725b9b1b92b3b0cb0999c57dbf31cc46cdc0781f4e91f315bd"}],"publication_id":"OT-2026-000089236"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089236
OpenTechnical

OT-2026-000089236

Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
4fcf6542fc50e31ab77bca47689f30c62e7ae1251b95386cb55f5e7c16ff5a86

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089236, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089236.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089236" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089236" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089236 Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089236 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089236 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089236 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089236", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1182 }, "figures": [], "files": [ { "bytes": 19058, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "afbc74e30ad7ff5088906d322d4a4fa1cc7800b598439fc1cc69fe266319484b" }, { "bytes": 8556, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5b52404e017d7d7b98372b2c0378bad83ba3caded9e445b802362f6b8de1f983" }, { "bytes": 8210, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4fcf6542fc50e31ab77bca47689f30c62e7ae1251b95386cb55f5e7c16ff5a86" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089236/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089236", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7cac-b160-b9206a48105a" } Hgo8+CoGS/St6gId/3572rCnNSsPeNBudUNGXH2Q2Hmaea1A7tAL6i77P5lxEKdqtnn5Z/FwQxY4mzgTMxeLBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Hgo8+CoGS/St6gId/3572rCnNSsPeNBudUNGXH2Q2Hmaea1A7tAL6i77P5lxEKdqtnn5Z/FwQxY4mzgTMxeLBw== {"files":[{"bytes":18677,"name":"index.html","sha256":"bb0ef91b39b17e7bbac864e23ffdeec07e39af9c2d58b58fd5162a253b47e3ab"},{"bytes":8216,"name":"publication.md","sha256":"0b9d5621b8b06972d7d04edfb085abc956fa07017980309329efa7f8377bd748"},{"bytes":7887,"name":"publication.txt","sha256":"c58ac0877fcb9bb48e8d117184031e06b74d4abc8d3ed7846cec0af0dd73bf10"},{"bytes":2836,"name":"manifest.json","sha256":"8406907b9dc36687995e26493c1613bfa3892dc3e60ccb161f857c52b1ce2b88"},{"bytes":89,"name":"manifest.sig","sha256":"6fbae73a115a6f5ae9194ffe2cb21a5316df2c9ee2876ffeafb49fa6eda76aa0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"61f9fbfd066c34d934c2ee63e872ada33cf0706a32a17b93f79dbdbcfaea0d9a"}],"publication_id":"OT-2026-000089237"} Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089237
OpenTechnical

OT-2026-000089237

Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
c58ac0877fcb9bb48e8d117184031e06b74d4abc8d3ed7846cec0af0dd73bf10

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089237, “Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089237.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089237" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089237" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089237 Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089237 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089237 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089237 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089237", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1151 }, "figures": [], "files": [ { "bytes": 18677, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bb0ef91b39b17e7bbac864e23ffdeec07e39af9c2d58b58fd5162a253b47e3ab" }, { "bytes": 8216, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0b9d5621b8b06972d7d04edfb085abc956fa07017980309329efa7f8377bd748" }, { "bytes": 7887, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c58ac0877fcb9bb48e8d117184031e06b74d4abc8d3ed7846cec0af0dd73bf10" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089237/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089237", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-70e0-a14b-c0c7589a5ef3" } ntA5ga8bCqnERyI003Wuasd87R3htBkPi2OkryLfMl81hBKhypLaG2IR28Kega+Wjld6zzW2xe4yaDOGolJcBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ntA5ga8bCqnERyI003Wuasd87R3htBkPi2OkryLfMl81hBKhypLaG2IR28Kega+Wjld6zzW2xe4yaDOGolJcBA== {"files":[{"bytes":19492,"name":"index.html","sha256":"39533b4f3a27c0b6dd1f1a8d6500a39622d66a0c959520fb8c8a1711dd6c1221"},{"bytes":8917,"name":"publication.md","sha256":"faf0762543087318ea32b819dbc6ff9d85b0e66fc642d41eb8ccd1b2e1aa3bd9"},{"bytes":8582,"name":"publication.txt","sha256":"23d6c95d4ad1c71882c31d636c0235ef24bc870cee13f7323fa1e93d51e3f8de"},{"bytes":2848,"name":"manifest.json","sha256":"f4dffa0c7377772ed04ab1e13a6f7908e920931b0be9791d2d95840cc8ea0162"},{"bytes":89,"name":"manifest.sig","sha256":"7d2e3a03f2e3c19ba49c35cb2b73b06f2980522d3b7644b920cad45e558d9e80"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f01569a7fdf085305f4150908cac89077ff4f5fb942e0ace35525a9b951ba030"}],"publication_id":"OT-2026-000089238"} Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089238
OpenTechnical

OT-2026-000089238

Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
23d6c95d4ad1c71882c31d636c0235ef24bc870cee13f7323fa1e93d51e3f8de

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089238, “Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089238.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089238" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089238" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089238 Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089238 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089238 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089238 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089238", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1257 }, "figures": [], "files": [ { "bytes": 19492, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "39533b4f3a27c0b6dd1f1a8d6500a39622d66a0c959520fb8c8a1711dd6c1221" }, { "bytes": 8917, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "faf0762543087318ea32b819dbc6ff9d85b0e66fc642d41eb8ccd1b2e1aa3bd9" }, { "bytes": 8582, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "23d6c95d4ad1c71882c31d636c0235ef24bc870cee13f7323fa1e93d51e3f8de" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089238/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089238", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-73aa-963e-88522c5f456b" } WiyYLVY0/6eOFnJ42oTnotDqD/jLjDzLlYML0RLPEHRkRmHovTT0x3HAxpu7sFaJ4CbI28JAVY1ij6uO6HGgDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: WiyYLVY0/6eOFnJ42oTnotDqD/jLjDzLlYML0RLPEHRkRmHovTT0x3HAxpu7sFaJ4CbI28JAVY1ij6uO6HGgDQ== {"files":[{"bytes":19239,"name":"index.html","sha256":"ef0137809a31814cee1e846e51e29e423479a4764ce12260e11d7aad972f1dcf"},{"bytes":8707,"name":"publication.md","sha256":"221fbc04dab945eb1308973cc9c6bc44a3133f1570b0d6324b7413458c863b73"},{"bytes":8372,"name":"publication.txt","sha256":"e61605b603caaf8c4be0c80ce414a6a580323cba5347ebe463eb4d36ea53be82"},{"bytes":2848,"name":"manifest.json","sha256":"4f486e1b08f010496798bb89842779003200ce7fd57c99eaa016b1ecdccf0ba8"},{"bytes":89,"name":"manifest.sig","sha256":"e82c1fa37457547c4f2158ca83e22409c6e303a21f35cacca819f46f523f22e8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"51db86f51559ede02da2308704c2a83cdb38c03e351598a0a22f25bcee5fc4fd"}],"publication_id":"OT-2026-000089239"} Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089239
OpenTechnical

OT-2026-000089239

Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e61605b603caaf8c4be0c80ce414a6a580323cba5347ebe463eb4d36ea53be82

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089239, “Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089239.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089239" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089239" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089239 Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089239 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089239 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089239 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089239", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1222 }, "figures": [], "files": [ { "bytes": 19239, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ef0137809a31814cee1e846e51e29e423479a4764ce12260e11d7aad972f1dcf" }, { "bytes": 8707, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "221fbc04dab945eb1308973cc9c6bc44a3133f1570b0d6324b7413458c863b73" }, { "bytes": 8372, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e61605b603caaf8c4be0c80ce414a6a580323cba5347ebe463eb4d36ea53be82" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089239/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089239", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7564-acb7-05eda7b5f7c6" } +js2Rxoqi66R75KfobC6EdUGiYiaxGM9oDl4OpqZjTX9qJE4BFFpqxgZ7l72xbqH69k1MU1ymRglMjFqYKJRDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: +js2Rxoqi66R75KfobC6EdUGiYiaxGM9oDl4OpqZjTX9qJE4BFFpqxgZ7l72xbqH69k1MU1ymRglMjFqYKJRDA== {"files":[{"bytes":18623,"name":"index.html","sha256":"73f05b6cc3cf88805437dbb34cae2c8e825d624328c494d51b312068960d8a6b"},{"bytes":8162,"name":"publication.md","sha256":"a25c2d43a3af644a5c21efd5ddeae81cb8299f1b44b7c1dcfb4616999042c666"},{"bytes":7833,"name":"publication.txt","sha256":"040c8586d4904384285a7ea118cff04ed3e59a6ce6954fc495848bbd74483e60"},{"bytes":2836,"name":"manifest.json","sha256":"a215db3a8f4526d21110f38f79ba1b278443270182961aa4aa1906cc672535ff"},{"bytes":89,"name":"manifest.sig","sha256":"3793a273a50da0f327ed614f6e34798c7f047d8123d305392b6c3881345a0dae"},{"bytes":227,"name":"manifest.sig.txt","sha256":"609011392d2991dd2079a4bbc699837ffd7663c1258033ebcebcd28e2ac6806a"}],"publication_id":"OT-2026-000089240"} Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089240
OpenTechnical

OT-2026-000089240

Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
040c8586d4904384285a7ea118cff04ed3e59a6ce6954fc495848bbd74483e60

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089240, “Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089240.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089240" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089240" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089240 Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089240 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089240 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089240 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089240", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1136 }, "figures": [], "files": [ { "bytes": 18623, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "73f05b6cc3cf88805437dbb34cae2c8e825d624328c494d51b312068960d8a6b" }, { "bytes": 8162, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a25c2d43a3af644a5c21efd5ddeae81cb8299f1b44b7c1dcfb4616999042c666" }, { "bytes": 7833, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "040c8586d4904384285a7ea118cff04ed3e59a6ce6954fc495848bbd74483e60" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089240/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089240", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-771b-b95d-11edb3e8c1f2" } TvCql3qJlng8BggjmiMmiVMT+2XapDZjMz5kBzzm59RB5bYUUAjcq/8bt/rt9XZS7UywsokMYfBeNAP7YLtGBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: TvCql3qJlng8BggjmiMmiVMT+2XapDZjMz5kBzzm59RB5bYUUAjcq/8bt/rt9XZS7UywsokMYfBeNAP7YLtGBw== {"files":[{"bytes":19438,"name":"index.html","sha256":"d5aafc0f96f93621791e06a8fa94f9ef55b1aa239abc8e7e958f0649b9ffdc95"},{"bytes":8863,"name":"publication.md","sha256":"f4c227f232c0f781be44cc9e875b0a3c8e3e96afd19edc5fc9598269ab88561e"},{"bytes":8528,"name":"publication.txt","sha256":"c4387f3ead1aeca48bfeeff48fbcb1aba165e47192429f27bc9fb842348cd360"},{"bytes":2848,"name":"manifest.json","sha256":"047fdf2be0ae98116bd22b3aeeba929dc189157c641741ce783ea890ee82a757"},{"bytes":89,"name":"manifest.sig","sha256":"3bb6e20b5fb592746364486e343af93d2752ef58bc357ce236c64d4bc4e5908e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"36c290965c908478509bb6658a6efa092a7dba3acb84a4864c93d904bd228fe9"}],"publication_id":"OT-2026-000089241"} Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089241
OpenTechnical

OT-2026-000089241

Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c4387f3ead1aeca48bfeeff48fbcb1aba165e47192429f27bc9fb842348cd360

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089241, “Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089241.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089241" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089241" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089241 Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089241 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089241 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089241 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089241", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1242 }, "figures": [], "files": [ { "bytes": 19438, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d5aafc0f96f93621791e06a8fa94f9ef55b1aa239abc8e7e958f0649b9ffdc95" }, { "bytes": 8863, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f4c227f232c0f781be44cc9e875b0a3c8e3e96afd19edc5fc9598269ab88561e" }, { "bytes": 8528, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c4387f3ead1aeca48bfeeff48fbcb1aba165e47192429f27bc9fb842348cd360" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089241/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089241", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7af0-b4c2-19e4989f37e9" } TXeN2+wMw1CYCmL9yfGx0ZEXn68p7qUfKjShq/xMhKGoELgpTaQhs0oOVRFdGzuiFcaR1hWfZsrZHhjy6UXWDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: TXeN2+wMw1CYCmL9yfGx0ZEXn68p7qUfKjShq/xMhKGoELgpTaQhs0oOVRFdGzuiFcaR1hWfZsrZHhjy6UXWDA== {"files":[{"bytes":19185,"name":"index.html","sha256":"68027e7e93a9baec38d8c8265ddf4298a7775ea1a02b57d9c9bec4f4c993c98d"},{"bytes":8653,"name":"publication.md","sha256":"c61d1419d8a6b0895b1c605cbff0abfeb68a0ca405dbd4980fed991384cdbf4b"},{"bytes":8318,"name":"publication.txt","sha256":"a84f484f0c996255be9685c874d773e5416007b547899727618b9639b9f3d8d0"},{"bytes":2848,"name":"manifest.json","sha256":"59e5e526cc301a90e30c9d70a06a890655dd9e3c967f7e61ca2ed4796f5d13f4"},{"bytes":89,"name":"manifest.sig","sha256":"6b1fb59fdf40719c967eb781a9945f0e046bb6eded4c0a64416ce15ec4ef0cef"},{"bytes":227,"name":"manifest.sig.txt","sha256":"77aa02c84b6f288731f4f7ee12ba440f0bc9940448d63c76a6f46d9f5edf4025"}],"publication_id":"OT-2026-000089242"} Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089242
OpenTechnical

OT-2026-000089242

Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a84f484f0c996255be9685c874d773e5416007b547899727618b9639b9f3d8d0

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089242, “Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089242.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089242" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089242" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089242 Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089242 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089242 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089242 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089242", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1207 }, "figures": [], "files": [ { "bytes": 19185, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "68027e7e93a9baec38d8c8265ddf4298a7775ea1a02b57d9c9bec4f4c993c98d" }, { "bytes": 8653, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c61d1419d8a6b0895b1c605cbff0abfeb68a0ca405dbd4980fed991384cdbf4b" }, { "bytes": 8318, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a84f484f0c996255be9685c874d773e5416007b547899727618b9639b9f3d8d0" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089242/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089242", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7907-9d67-e301a83e1ad9" } qFYhB8Kurw0Jcir/CM8++0gBMS9+mApwDtP4inKEe4ICdVQn9J/eQcSokibnl0ISomGTMb24DbFzc9s8noXeDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: qFYhB8Kurw0Jcir/CM8++0gBMS9+mApwDtP4inKEe4ICdVQn9J/eQcSokibnl0ISomGTMb24DbFzc9s8noXeDA== {"files":[{"bytes":18385,"name":"index.html","sha256":"53caab65a89f923615837467e3c2b872c008a932796033e3570225763ec8574b"},{"bytes":7970,"name":"publication.md","sha256":"b2eb040f48b32116cc010aabe8033d21b5131989b945f29d643a204fe928e47d"},{"bytes":7638,"name":"publication.txt","sha256":"d699af494fe1a13af3a753069e45a1f8f6ecba2626bab6c54a379a59b82db8ea"},{"bytes":2851,"name":"manifest.json","sha256":"4e9a87103f89585c912538ccab0ae4f0a74c6fd09ad16787976a67d4a97fcb5a"},{"bytes":89,"name":"manifest.sig","sha256":"777fc411059cf4de4178606146536e99f205c1cdadbcaa68c54eda6e615779ab"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f625c7a8fc59150d67f1c6819131fa4918c766132b416ea0e8dbd2a7211d2fe8"}],"publication_id":"OT-2026-000089243"} Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089243
OpenTechnical

OT-2026-000089243

Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
d699af494fe1a13af3a753069e45a1f8f6ecba2626bab6c54a379a59b82db8ea

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089243, “Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089243.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089243" title: "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089243" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089243 Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089243 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089243 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089243 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089243", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18385, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "53caab65a89f923615837467e3c2b872c008a932796033e3570225763ec8574b" }, { "bytes": 7970, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b2eb040f48b32116cc010aabe8033d21b5131989b945f29d643a204fe928e47d" }, { "bytes": 7638, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d699af494fe1a13af3a753069e45a1f8f6ecba2626bab6c54a379a59b82db8ea" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089243/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089243", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-757a-b1fa-205af0c18dbd" } BBrAofz9TqHgX7iktsBra72XZUlihB/dT2F5I8qrJHAlfTGTiSz3PP+7jfTGCXV9SlUdM3OT+c1L/pivkYNQCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: BBrAofz9TqHgX7iktsBra72XZUlihB/dT2F5I8qrJHAlfTGTiSz3PP+7jfTGCXV9SlUdM3OT+c1L/pivkYNQCg== {"files":[{"bytes":19200,"name":"index.html","sha256":"ba994a134f16c04fef825389fa000b42f9821bf9773463037c5b6f5470d2c37a"},{"bytes":8671,"name":"publication.md","sha256":"503aed0783a7cd37ddc4fe655e4094bd8368d3977e71e2de1a335bbbbf1bc5d3"},{"bytes":8333,"name":"publication.txt","sha256":"e59ed699fc176897378378ab1c3032578ff272a6fad4dec3b16300d42d8d537c"},{"bytes":2863,"name":"manifest.json","sha256":"d83365bff6ec8780f9c3be609f417caad951d1d0bbc97579872b3827d41eaa34"},{"bytes":89,"name":"manifest.sig","sha256":"4620cca39ab5620bd9478459436d7fd5ad25a435571037545963625fde2b6d9b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2396064e3f068e3be340d3dd6e25fc152e7fa2774e33cc417a36fd90b93a4e8d"}],"publication_id":"OT-2026-000089244"} Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089244
OpenTechnical

OT-2026-000089244

Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e59ed699fc176897378378ab1c3032578ff272a6fad4dec3b16300d42d8d537c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089244, “Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089244.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089244" title: "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089244" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089244 Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089244 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089244 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089244 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089244", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19200, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ba994a134f16c04fef825389fa000b42f9821bf9773463037c5b6f5470d2c37a" }, { "bytes": 8671, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "503aed0783a7cd37ddc4fe655e4094bd8368d3977e71e2de1a335bbbbf1bc5d3" }, { "bytes": 8333, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e59ed699fc176897378378ab1c3032578ff272a6fad4dec3b16300d42d8d537c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089244/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089244", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7967-a54d-9f5f81d5e3b1" } MjHgqPR3JR3eAgZS/5eCm7KHloLlIY3ul4DUq5YJF4M4EUa1JBsMFEqgDb+0cPIoNCDI1FWVbLsWe8kKyb0PAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: MjHgqPR3JR3eAgZS/5eCm7KHloLlIY3ul4DUq5YJF4M4EUa1JBsMFEqgDb+0cPIoNCDI1FWVbLsWe8kKyb0PAg== {"files":[{"bytes":18947,"name":"index.html","sha256":"99f3ff4ebc5bb8d26ed4788e78787d10542d4e1b705fc5c9c61692f1cd4f135c"},{"bytes":8461,"name":"publication.md","sha256":"525a3bc7f3a5798e2fe96c541ce12d02b12262fa9be9ac9bba6e6883d43be947"},{"bytes":8123,"name":"publication.txt","sha256":"5fdf60299cadba1eab464d6b33a7bc095a6bfca0d6cb59168e62f4d82fc30c36"},{"bytes":2863,"name":"manifest.json","sha256":"d8d8cbca0b84b2c2be74570e6ba2f5ec1e9071319a7d20788f29848fb3c53ab0"},{"bytes":89,"name":"manifest.sig","sha256":"16e9019f6a8fd3b6dbf908c7152dfc0e96ec58ec161698a9b03013e5428272cb"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a14463385431e94cbb17cafa688746e695ea5110507c82ac7958b9639c6576a4"}],"publication_id":"OT-2026-000089245"} Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089245
OpenTechnical

OT-2026-000089245

Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
5fdf60299cadba1eab464d6b33a7bc095a6bfca0d6cb59168e62f4d82fc30c36

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089245, “Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089245.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089245" title: "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089245" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089245 Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089245 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089245 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089245 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089245", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18947, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "99f3ff4ebc5bb8d26ed4788e78787d10542d4e1b705fc5c9c61692f1cd4f135c" }, { "bytes": 8461, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "525a3bc7f3a5798e2fe96c541ce12d02b12262fa9be9ac9bba6e6883d43be947" }, { "bytes": 8123, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5fdf60299cadba1eab464d6b33a7bc095a6bfca0d6cb59168e62f4d82fc30c36" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089245/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089245", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7c15-b640-e1cf5fea9fc3" } ax+iu6xaqTuoO2hCj732MpphQ2Go8j4UohZK95waPtxR2FrpnFq8w9xpmfuOmR2xVjncIAu14xJ+MHS/XfocCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ax+iu6xaqTuoO2hCj732MpphQ2Go8j4UohZK95waPtxR2FrpnFq8w9xpmfuOmR2xVjncIAu14xJ+MHS/XfocCA== {"files":[{"bytes":18385,"name":"index.html","sha256":"ad00e4861f15fbd5ccbba0d8857d2401eb62699b0dee01abc25692f09d288216"},{"bytes":7970,"name":"publication.md","sha256":"82897a4344473ac4e13c6efb760d4e53f7c0dfed093940722a10b05c90f7dbb9"},{"bytes":7638,"name":"publication.txt","sha256":"c540737fdaa72fe1b918a1d2e08a5114c397778a853c079693c25fd78ad5bc7f"},{"bytes":2851,"name":"manifest.json","sha256":"e8909045e6cfeda42836dd2df71a1948af24d29abe9f4ec73df1d94b2a0f39e5"},{"bytes":89,"name":"manifest.sig","sha256":"602d654152c5321c102ec37c9622a172f65bf85519d058fced7efd550185826b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c8983ac235a299e67f289e25647d1d058ca62c6c6d1cf2f97aa14cde564f5fd1"}],"publication_id":"OT-2026-000089246"} Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089246
OpenTechnical

OT-2026-000089246

Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
c540737fdaa72fe1b918a1d2e08a5114c397778a853c079693c25fd78ad5bc7f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089246, “Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089246.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089246" title: "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089246" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089246 Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089246 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089246 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089246 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089246", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1099 }, "figures": [], "files": [ { "bytes": 18385, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ad00e4861f15fbd5ccbba0d8857d2401eb62699b0dee01abc25692f09d288216" }, { "bytes": 7970, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "82897a4344473ac4e13c6efb760d4e53f7c0dfed093940722a10b05c90f7dbb9" }, { "bytes": 7638, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c540737fdaa72fe1b918a1d2e08a5114c397778a853c079693c25fd78ad5bc7f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089246/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089246", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7dff-bd08-59096f548d1f" } 6hzq/Fj8f8MrB9PNLVBDfIoiFLh9Rl/KVJMH7R2iZBChoy5RpQ3Q3tOB+AbMqtTddVzKIpH5mTTOEuXpeSVqCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 6hzq/Fj8f8MrB9PNLVBDfIoiFLh9Rl/KVJMH7R2iZBChoy5RpQ3Q3tOB+AbMqtTddVzKIpH5mTTOEuXpeSVqCA== {"files":[{"bytes":19200,"name":"index.html","sha256":"f72d1f1a745e72cf06bb664cd6ade65c5202ddcd2764c2bccf34883e70553f0c"},{"bytes":8671,"name":"publication.md","sha256":"fd676409629aca9c8e5cc4436779b9007086e150c362d33a55e258ad60b927b6"},{"bytes":8333,"name":"publication.txt","sha256":"d786738e96f14472307e2474eff7d2b3c7b81345326ba08d9a6067e841520d7d"},{"bytes":2863,"name":"manifest.json","sha256":"00d3a65b5c16271ea6980c4b747dd8f1205e4c398c6d6a46be5894bb19c709f7"},{"bytes":89,"name":"manifest.sig","sha256":"174d572201a78199d0ba214ceccce7153d07bfda4e10ce0f172a44d5c63d4f78"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3ba67f38208af7276bdbc00b04ae8520fc862ea80245a24ac5f4e0e01be3dc73"}],"publication_id":"OT-2026-000089247"} Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089247
OpenTechnical

OT-2026-000089247

Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
d786738e96f14472307e2474eff7d2b3c7b81345326ba08d9a6067e841520d7d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089247, “Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089247.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089247" title: "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089247" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089247 Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089247 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089247 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089247 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089247", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19200, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f72d1f1a745e72cf06bb664cd6ade65c5202ddcd2764c2bccf34883e70553f0c" }, { "bytes": 8671, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fd676409629aca9c8e5cc4436779b9007086e150c362d33a55e258ad60b927b6" }, { "bytes": 8333, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d786738e96f14472307e2474eff7d2b3c7b81345326ba08d9a6067e841520d7d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089247/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089247", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7d37-bad9-33877756ecf1" } q/TMoZmY1Z8dZlgoxgFo/n6oB9KiPjZq32o2idf/K3dQQrNJwrA8xZNkVUhpvu/5BJGeRFDgQBwjfqdRUBX5Bw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: q/TMoZmY1Z8dZlgoxgFo/n6oB9KiPjZq32o2idf/K3dQQrNJwrA8xZNkVUhpvu/5BJGeRFDgQBwjfqdRUBX5Bw== {"files":[{"bytes":18947,"name":"index.html","sha256":"5387db26b2a9c23bd3415badde096b1afdf8106f19abbc3a4b77877be443eb8c"},{"bytes":8461,"name":"publication.md","sha256":"bfbda611b65b0c15c63f4e5336046cf3cd08bc1fac538a97fe472373d3870a21"},{"bytes":8123,"name":"publication.txt","sha256":"ddb62516cf47457ec063eb1c6435f4aa12534a3f5da516f973ffa38e50391c25"},{"bytes":2863,"name":"manifest.json","sha256":"0397559bb32aea6257044d380654d6e5f81399f01fee630a947a6761a8a58ca3"},{"bytes":89,"name":"manifest.sig","sha256":"fc28430c1bb78a5f9f2ed4d12da11cc5a52ccab5316733cc4469b493b43e5fd7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"37370edf183ddc3a34fbdf9279f68ce2623f1d1fda25d1c77ac221ff41c3c91e"}],"publication_id":"OT-2026-000089248"} Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089248
OpenTechnical

OT-2026-000089248

Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
ddb62516cf47457ec063eb1c6435f4aa12534a3f5da516f973ffa38e50391c25

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089248, “Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089248.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089248" title: "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089248" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089248 Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089248 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the ejector and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089248 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089248 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one ejector, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089248", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1170 }, "figures": [], "files": [ { "bytes": 18947, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5387db26b2a9c23bd3415badde096b1afdf8106f19abbc3a4b77877be443eb8c" }, { "bytes": 8461, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "bfbda611b65b0c15c63f4e5336046cf3cd08bc1fac538a97fe472373d3870a21" }, { "bytes": 8123, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ddb62516cf47457ec063eb1c6435f4aa12534a3f5da516f973ffa38e50391c25" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089248/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089248", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, three stage ejector, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-74c8-8b80-14e9d0aa3b3c" } bq3IkncN6BB8ZwI4LiOF/tutxrZ8QgvOO7bOJcXWjQCtN6wi/w/povE7jw0M2jt5l5vELpn3n8FEsFK63iWxDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: bq3IkncN6BB8ZwI4LiOF/tutxrZ8QgvOO7bOJcXWjQCtN6wi/w/povE7jw0M2jt5l5vELpn3n8FEsFK63iWxDA== {"files":[{"bytes":18398,"name":"index.html","sha256":"ca27c4933ac0aa5d44b874b29b39d3390807eba9b88f31c4564a897338049bf3"},{"bytes":8036,"name":"publication.md","sha256":"d2185dbca20a5be75afac2bda10e5228b7851f4edf76f32360f6079783e22ec5"},{"bytes":7676,"name":"publication.txt","sha256":"2d0071b77064acf79ad39e98e9a3cda8269cccd273fa835aeb467800e510e322"},{"bytes":2911,"name":"manifest.json","sha256":"7817ac2730b69f5e571916a1b52b5047df14fd964baf697730fea6ef85cd0634"},{"bytes":89,"name":"manifest.sig","sha256":"df1bfd5a6a90a6305e39a4294c42225e83607e18a0eb3205c310b021e281cb3a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"fe8f2c0d5d6779327a5dfb1a301202a9ca9cca9ac52dab4d00edfd3ec7a9e44c"}],"publication_id":"OT-2026-000089249"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089249
OpenTechnical

OT-2026-000089249

Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
2d0071b77064acf79ad39e98e9a3cda8269cccd273fa835aeb467800e510e322

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089249, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089249.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089249" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089249" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089249 Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089249 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089249 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089249 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089249", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1096 }, "figures": [], "files": [ { "bytes": 18398, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ca27c4933ac0aa5d44b874b29b39d3390807eba9b88f31c4564a897338049bf3" }, { "bytes": 8036, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d2185dbca20a5be75afac2bda10e5228b7851f4edf76f32360f6079783e22ec5" }, { "bytes": 7676, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2d0071b77064acf79ad39e98e9a3cda8269cccd273fa835aeb467800e510e322" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089249/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089249", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7af3-9662-e45fdad1eb18" } y++WXyExD19T8FH1XUX/5gs5+sUTljwtdxQoTv3r5IhQbvHLUK5Vu08uSuaD7F031tfq/QY2oWsHTkOTjfCwCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: y++WXyExD19T8FH1XUX/5gs5+sUTljwtdxQoTv3r5IhQbvHLUK5Vu08uSuaD7F031tfq/QY2oWsHTkOTjfCwCA== {"files":[{"bytes":19204,"name":"index.html","sha256":"5ff1df5612c3037d64890bc9de6206476e1f88cec7ffe0c3230077d914b910e6"},{"bytes":8724,"name":"publication.md","sha256":"3e613aa9017c807bdfc830ab06c952ff394bc38efc2f82bc5f389aa0da8685ca"},{"bytes":8365,"name":"publication.txt","sha256":"156666c029d2b60621fa91c917ee1fb78386e7cf9bba12ce7087b15e60ff2ccf"},{"bytes":2916,"name":"manifest.json","sha256":"6607c3f57589c943e10f7427b93ec585e71e06fc2cedbc1943fa6ce9947f9273"},{"bytes":89,"name":"manifest.sig","sha256":"9e8e459dd6e27cc40e1209258097ba4b8694bda04383531610fe3cdc530df06e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a437ffb0da640e1caa441a4add50c93c84cbda74b8f124f01432c63206c7303e"}],"publication_id":"OT-2026-000089250"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089250
OpenTechnical

OT-2026-000089250

Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
156666c029d2b60621fa91c917ee1fb78386e7cf9bba12ce7087b15e60ff2ccf

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089250, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089250.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089250" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089250" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089250 Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089250 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089250 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089250 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089250", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19204, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5ff1df5612c3037d64890bc9de6206476e1f88cec7ffe0c3230077d914b910e6" }, { "bytes": 8724, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3e613aa9017c807bdfc830ab06c952ff394bc38efc2f82bc5f389aa0da8685ca" }, { "bytes": 8365, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "156666c029d2b60621fa91c917ee1fb78386e7cf9bba12ce7087b15e60ff2ccf" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089250/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089250", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7589-841d-139127ea6767" } aEk21K1MEurQHEbiEnf3PJqBAo26AZxq9PtZC3ylSIWqH9C1qVgemuSErGzFbTOFN9ZXEokuSwHFNDwZ6GabDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: aEk21K1MEurQHEbiEnf3PJqBAo26AZxq9PtZC3ylSIWqH9C1qVgemuSErGzFbTOFN9ZXEokuSwHFNDwZ6GabDg== {"files":[{"bytes":18951,"name":"index.html","sha256":"bbb92c6b6dc0fb4c00444c30dcf190b42cba16c46350bc7defd28bf9fc6eb8cd"},{"bytes":8514,"name":"publication.md","sha256":"78117ce2521b607d90d9c519ffa9036b644a5926dd311a45982e6ed41e06acc8"},{"bytes":8155,"name":"publication.txt","sha256":"3be38d7e120db7dfa8d4b9614e287d3d1fbc5b010a7d504e2cb823b1b09abeb5"},{"bytes":2916,"name":"manifest.json","sha256":"d28b6eda06f835e516c5b17d2c7eedab2fba2604ba7a1b0d0cdc6b795e7e8c9f"},{"bytes":89,"name":"manifest.sig","sha256":"2c27109d7ce33d7ca095287d3cc648d30f9155d14aee0b72ad743a886a699bed"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d9e115111006f51dbf4dd846cb4e771faeba47db0758a1b8e805c6e5070c20e3"}],"publication_id":"OT-2026-000089251"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089251
OpenTechnical

OT-2026-000089251

Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
3be38d7e120db7dfa8d4b9614e287d3d1fbc5b010a7d504e2cb823b1b09abeb5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089251, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089251.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089251" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089251" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089251 Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089251 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089251 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089251 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089251", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1167 }, "figures": [], "files": [ { "bytes": 18951, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bbb92c6b6dc0fb4c00444c30dcf190b42cba16c46350bc7defd28bf9fc6eb8cd" }, { "bytes": 8514, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "78117ce2521b607d90d9c519ffa9036b644a5926dd311a45982e6ed41e06acc8" }, { "bytes": 8155, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3be38d7e120db7dfa8d4b9614e287d3d1fbc5b010a7d504e2cb823b1b09abeb5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089251/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089251", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7c6b-b8fa-10b350a068da" } sfozFdUC8nTtLAOCqs0nrd3KamhXYRv40bL76UpTWrlqJid6mNCXN2Yi+cyZ0K2ozKIRKTt3RY45ksYQ4ANYDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: sfozFdUC8nTtLAOCqs0nrd3KamhXYRv40bL76UpTWrlqJid6mNCXN2Yi+cyZ0K2ozKIRKTt3RY45ksYQ4ANYDQ== {"files":[{"bytes":18399,"name":"index.html","sha256":"f6855fa0784689f532464ec85fedcd8349a423bc5bd7ecd129a7ff28959cb639"},{"bytes":8037,"name":"publication.md","sha256":"6431ed2d81afac497c3b46c406afd25c814e5e7e6a6122a26360fbf2fcc7f95a"},{"bytes":7677,"name":"publication.txt","sha256":"8670eb54f2b5d3fef7d39d66ba119fa027918dd6e71b3a39f0567c951a077bf7"},{"bytes":2911,"name":"manifest.json","sha256":"28ef6c2f14332f848d505ac6abfdfea3dfa813654a69a06351cce31afbc700d0"},{"bytes":89,"name":"manifest.sig","sha256":"5e3dc4185ed4942d62413cd6bfe3ac27390a4501d560cb27da786323459f0309"},{"bytes":227,"name":"manifest.sig.txt","sha256":"317553219a7071a8fa809dcfc3afaed0f2d80621fc06247db567f4dbb73fce6f"}],"publication_id":"OT-2026-000089252"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089252
OpenTechnical

OT-2026-000089252

Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
8670eb54f2b5d3fef7d39d66ba119fa027918dd6e71b3a39f0567c951a077bf7

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089252, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089252.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089252" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089252" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089252 Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089252 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089252 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089252 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089252", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1096 }, "figures": [], "files": [ { "bytes": 18399, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f6855fa0784689f532464ec85fedcd8349a423bc5bd7ecd129a7ff28959cb639" }, { "bytes": 8037, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "6431ed2d81afac497c3b46c406afd25c814e5e7e6a6122a26360fbf2fcc7f95a" }, { "bytes": 7677, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8670eb54f2b5d3fef7d39d66ba119fa027918dd6e71b3a39f0567c951a077bf7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089252/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089252", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7aba-a52d-c30d3569ebe0" } oOTzT2h19WUHtEfCaXvjcXvmypPFOEvBWf3YrDJk/5CaUj99Xbk6toosftgS7b1bnW/KywBh2DxrfzPovQhVBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: oOTzT2h19WUHtEfCaXvjcXvmypPFOEvBWf3YrDJk/5CaUj99Xbk6toosftgS7b1bnW/KywBh2DxrfzPovQhVBw== {"files":[{"bytes":19205,"name":"index.html","sha256":"bd08d0674818f97c06be07c22d35eacf086ca05b474811837dc9e018a61c7d2d"},{"bytes":8725,"name":"publication.md","sha256":"e74faa2a6e4b7dac40c25e4cd64ec87b18eeb0f51be948adf945baa5bcd16ec1"},{"bytes":8366,"name":"publication.txt","sha256":"9f81f59b5db63c9f6b133245ff8b6da1a952054757f733784d92bd27920bfbc3"},{"bytes":2916,"name":"manifest.json","sha256":"51c4361faff12cc1c1c7e99226c696ced1f3f67749aa22209aa2167653b7ba40"},{"bytes":89,"name":"manifest.sig","sha256":"f7d76b56b0ca0e3826b650c3add53745ef4609e5f8ea7b92f703bfbeb6b2cfee"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3fe1ac6d3aeaa2c712c9d0fc622694e8c3e27e76de3f45aaa8cc864390fe3405"}],"publication_id":"OT-2026-000089253"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089253
OpenTechnical

OT-2026-000089253

Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
9f81f59b5db63c9f6b133245ff8b6da1a952054757f733784d92bd27920bfbc3

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089253, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089253.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089253" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089253" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089253 Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089253 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089253 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089253 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089253", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19205, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bd08d0674818f97c06be07c22d35eacf086ca05b474811837dc9e018a61c7d2d" }, { "bytes": 8725, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e74faa2a6e4b7dac40c25e4cd64ec87b18eeb0f51be948adf945baa5bcd16ec1" }, { "bytes": 8366, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9f81f59b5db63c9f6b133245ff8b6da1a952054757f733784d92bd27920bfbc3" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089253/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089253", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7f28-a992-755844571942" } XxbZlfxyCElKRqhd9hhu0fDyTw453OfASNV9xF/EwpiOQQIbItB8NajFeHaHtLyxkEsd+m+oAG6uWas/yKDzBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: XxbZlfxyCElKRqhd9hhu0fDyTw453OfASNV9xF/EwpiOQQIbItB8NajFeHaHtLyxkEsd+m+oAG6uWas/yKDzBQ== {"files":[{"bytes":18952,"name":"index.html","sha256":"6848f0e8dbb8f0b6087e371eb8d907cc1e0359afe5395be8205f6a7403668a0c"},{"bytes":8515,"name":"publication.md","sha256":"6efbe83036759882f0db32fe10419470b61cf1616a84e161e9c48c2e5092650d"},{"bytes":8156,"name":"publication.txt","sha256":"3e4e8456f79e310781e6fc1573b70fc0d52a3444ea4c83c50f94d87856126cd7"},{"bytes":2916,"name":"manifest.json","sha256":"782623fdf37b0d44adc0453e0793794dd37a192a59f41c515e7edeb64e33b615"},{"bytes":89,"name":"manifest.sig","sha256":"24cffd0ce6e9663769609308a4c0e09e8e3eac3736f4ba77d2a10432f9f54d8e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"37d79f14cd1d80e40fb045409f80c7d25d578fe4c42f8d137b80cc71f6900a64"}],"publication_id":"OT-2026-000089254"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089254
OpenTechnical

OT-2026-000089254

Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
3e4e8456f79e310781e6fc1573b70fc0d52a3444ea4c83c50f94d87856126cd7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089254, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089254.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089254" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089254" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089254 Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089254 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089254 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089254 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089254", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1167 }, "figures": [], "files": [ { "bytes": 18952, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6848f0e8dbb8f0b6087e371eb8d907cc1e0359afe5395be8205f6a7403668a0c" }, { "bytes": 8515, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "6efbe83036759882f0db32fe10419470b61cf1616a84e161e9c48c2e5092650d" }, { "bytes": 8156, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3e4e8456f79e310781e6fc1573b70fc0d52a3444ea4c83c50f94d87856126cd7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089254/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089254", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-767f-9863-ed80dee0df0f" } Qgpne2Njb9qrgYeMoAcXRaIplErLh7yJh13yF56o4CwgooVDpDFSXe1fOm3Xald9zlT/5PksOmmRQbtYUoCeBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Qgpne2Njb9qrgYeMoAcXRaIplErLh7yJh13yF56o4CwgooVDpDFSXe1fOm3Xald9zlT/5PksOmmRQbtYUoCeBQ== {"files":[{"bytes":18403,"name":"index.html","sha256":"dc57332ac707b7f7828e6280f5a2e3a2aaa7e09af908fc16a80810be52b1a927"},{"bytes":8041,"name":"publication.md","sha256":"d06433b54725de52f8f3c8bdd3ffc3e55e6e98fc0db5edf60f209a712c13a113"},{"bytes":7681,"name":"publication.txt","sha256":"87937814dd18619c15b7dab06eb90a6160b9d7810fc83481913888d0795a2077"},{"bytes":2911,"name":"manifest.json","sha256":"de9245dcaa08f62ae2e9fae27c3855f1a795dba0db29a347c13c2f0bac7afaee"},{"bytes":89,"name":"manifest.sig","sha256":"eb49d141758839bce992a47faf1858c0b8aa2157db466d4e2b2a728b92666a74"},{"bytes":227,"name":"manifest.sig.txt","sha256":"cdf2f527e369354d7adf2ceae4ad891052f8f785d7b6bb287d9a200977d6f8b7"}],"publication_id":"OT-2026-000089255"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089255
OpenTechnical

OT-2026-000089255

Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
87937814dd18619c15b7dab06eb90a6160b9d7810fc83481913888d0795a2077

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089255, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089255.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089255" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089255" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089255 Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089255 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089255 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089255 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089255", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1096 }, "figures": [], "files": [ { "bytes": 18403, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "dc57332ac707b7f7828e6280f5a2e3a2aaa7e09af908fc16a80810be52b1a927" }, { "bytes": 8041, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d06433b54725de52f8f3c8bdd3ffc3e55e6e98fc0db5edf60f209a712c13a113" }, { "bytes": 7681, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "87937814dd18619c15b7dab06eb90a6160b9d7810fc83481913888d0795a2077" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089255/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089255", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7ca5-b270-52c64fe7f828" } OfFaImKg3LpKASCX5eIgC19eV0jC+Na4WP8KTLwADjraflWYOCh/DVg4RW6KLjYuZzetdhvFAPBPfc9RTRo2AQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: OfFaImKg3LpKASCX5eIgC19eV0jC+Na4WP8KTLwADjraflWYOCh/DVg4RW6KLjYuZzetdhvFAPBPfc9RTRo2AQ== {"files":[{"bytes":19209,"name":"index.html","sha256":"d266ea68e6c61982ff74d718775d84125f0d0e6bcb142c2679f6721deafbf2dd"},{"bytes":8729,"name":"publication.md","sha256":"876d46d12ce1f200058fd80a3732c97468d9f2f858f8e35dee3506f9d6c21f1a"},{"bytes":8370,"name":"publication.txt","sha256":"bf164f9190a47b2c085921e8223f23ab2fa67fae49ed2443bd58393e551cc77f"},{"bytes":2916,"name":"manifest.json","sha256":"be5dd1d0af90957bbd744f70d7042bcb8a87c86bdb37753938ccd8f7f0f0712d"},{"bytes":89,"name":"manifest.sig","sha256":"701aaaa92acad3d825b7bdb033a89777f206d0ab71a3ca585f55dab50eaa7ec2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"5134b77318094c7dc59111da537f5c542e94f5d57cf534f0d30d55634c275ae5"}],"publication_id":"OT-2026-000089256"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089256
OpenTechnical

OT-2026-000089256

Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
bf164f9190a47b2c085921e8223f23ab2fa67fae49ed2443bd58393e551cc77f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089256, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089256.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089256" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089256" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089256 Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089256 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089256 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089256 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089256", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19209, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d266ea68e6c61982ff74d718775d84125f0d0e6bcb142c2679f6721deafbf2dd" }, { "bytes": 8729, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "876d46d12ce1f200058fd80a3732c97468d9f2f858f8e35dee3506f9d6c21f1a" }, { "bytes": 8370, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "bf164f9190a47b2c085921e8223f23ab2fa67fae49ed2443bd58393e551cc77f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089256/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089256", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7627-9702-ce6b7156908e" } Nmloqhvv5qRrahgajCVCRYzKxyptal7dfc9iYYVVpOynU51HKiauRWufdXA6ZKiBba5a03F3WR9Lk3v6avRHAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Nmloqhvv5qRrahgajCVCRYzKxyptal7dfc9iYYVVpOynU51HKiauRWufdXA6ZKiBba5a03F3WR9Lk3v6avRHAg== {"files":[{"bytes":18956,"name":"index.html","sha256":"241127dd9980b3e5bcfa32bff1a7e744c42f64c2a028e54d1041b013d804139d"},{"bytes":8519,"name":"publication.md","sha256":"de53f52dd554a43366273d9405c95b468ffca9de7ce316c71b2c641d89c3b9f5"},{"bytes":8160,"name":"publication.txt","sha256":"b06bc926469ffc4bad104b259f16810f61f21be9aebdaac970f6576874c5cca0"},{"bytes":2916,"name":"manifest.json","sha256":"e69f9ab6ea75790a7a36bad6c8a90f2ed51acec4cc1c555b7fb51bdb9e17cb57"},{"bytes":89,"name":"manifest.sig","sha256":"46d0939fdf35458d5d8bd695a3dea38ef75fa6c177fb3c2514ab98108022533d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"599f0929ef1529180eaef5674aebd2e0ef504391503f0963a8e0ef1ae5dbf92c"}],"publication_id":"OT-2026-000089257"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089257
OpenTechnical

OT-2026-000089257

Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
b06bc926469ffc4bad104b259f16810f61f21be9aebdaac970f6576874c5cca0

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089257, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089257.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089257" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089257" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089257 Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089257 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089257 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089257 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089257", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1167 }, "figures": [], "files": [ { "bytes": 18956, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "241127dd9980b3e5bcfa32bff1a7e744c42f64c2a028e54d1041b013d804139d" }, { "bytes": 8519, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "de53f52dd554a43366273d9405c95b468ffca9de7ce316c71b2c641d89c3b9f5" }, { "bytes": 8160, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b06bc926469ffc4bad104b259f16810f61f21be9aebdaac970f6576874c5cca0" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089257/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089257", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7f78-b28a-f9c041b558a8" } mK13a74Z5zvAl9UBqP9n7QnTJHBNCpQE8VN27W+f42jaKjR2f2aQgB/QNtqrMa6nvMgtxO66bC96vnnXLktiAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: mK13a74Z5zvAl9UBqP9n7QnTJHBNCpQE8VN27W+f42jaKjR2f2aQgB/QNtqrMa6nvMgtxO66bC96vnnXLktiAQ== {"files":[{"bytes":18584,"name":"index.html","sha256":"8b6eb82485b986ca16b3307a7b505ee67bb98abed4f62c428feb4c1e610a4c20"},{"bytes":8192,"name":"publication.md","sha256":"90d9e56301ceabe55315c05af7b46ea8deefcf96f6d58d328ad4ad0b75c7a4cb"},{"bytes":7843,"name":"publication.txt","sha256":"9260a13e275b58dbe050f2cacad307e6b78cf53f71a2199bfcbf01333887c5ed"},{"bytes":2888,"name":"manifest.json","sha256":"83f9d2ef83d767c91ae857ba7784b4f1a69423f1c773d109241df8e7599a91d6"},{"bytes":89,"name":"manifest.sig","sha256":"38dfc7f1622b7c356e7b62bbbeb8d4343703fafcff03e185b5b8bb2c7d24c34d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4ff069be1b44f9799315746bb956e2605920cfe83e0d7eb607fcae3ebb4f2136"}],"publication_id":"OT-2026-000089258"} Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089258
OpenTechnical

OT-2026-000089258

Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
9260a13e275b58dbe050f2cacad307e6b78cf53f71a2199bfcbf01333887c5ed

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089258, “Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089258.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089258" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089258" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089258 Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089258 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089258 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089258 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089258", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1136 }, "figures": [], "files": [ { "bytes": 18584, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8b6eb82485b986ca16b3307a7b505ee67bb98abed4f62c428feb4c1e610a4c20" }, { "bytes": 8192, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "90d9e56301ceabe55315c05af7b46ea8deefcf96f6d58d328ad4ad0b75c7a4cb" }, { "bytes": 7843, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9260a13e275b58dbe050f2cacad307e6b78cf53f71a2199bfcbf01333887c5ed" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089258/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089258", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-766f-b487-a16a3641b9f2" } I4l01ANCm6zv8Bh4k5B6eSsrWax7jcqYk16aPINiBggkYZ/+sL4PA5ekXIVYuN1ib12mDgmobl3JM68KZ8ZjAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: I4l01ANCm6zv8Bh4k5B6eSsrWax7jcqYk16aPINiBggkYZ/+sL4PA5ekXIVYuN1ib12mDgmobl3JM68KZ8ZjAw== {"files":[{"bytes":19390,"name":"index.html","sha256":"f6c9acf807b1a964fa3ea02afd19b3d80831626c1a3338e738322039121dd8f4"},{"bytes":8880,"name":"publication.md","sha256":"cc0117faf4cccf0519932b1266334b11254b5bbcd421f32d4dd6827d4caec73d"},{"bytes":8532,"name":"publication.txt","sha256":"eddf1e2c455beac4a431b152590650fd15749cd91884936f5fc61a1692b49889"},{"bytes":2893,"name":"manifest.json","sha256":"d4d0e8778a6d3e42084c0a030b6fb29badd57d03f584fe5be565ff48fec120f5"},{"bytes":89,"name":"manifest.sig","sha256":"5b10e965ab4996f44d746ed0c7b9338cae347de26707087ee445e412fa03d377"},{"bytes":227,"name":"manifest.sig.txt","sha256":"6af7c64fc363f7e2d4e67c00e30f18b85216a9ea1efae8cb6ab1e68efee1b8fb"}],"publication_id":"OT-2026-000089259"} Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089259
OpenTechnical

OT-2026-000089259

Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
eddf1e2c455beac4a431b152590650fd15749cd91884936f5fc61a1692b49889

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089259, “Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089259.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089259" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089259" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089259 Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089259 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089259 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089259 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089259", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1242 }, "figures": [], "files": [ { "bytes": 19390, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f6c9acf807b1a964fa3ea02afd19b3d80831626c1a3338e738322039121dd8f4" }, { "bytes": 8880, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cc0117faf4cccf0519932b1266334b11254b5bbcd421f32d4dd6827d4caec73d" }, { "bytes": 8532, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "eddf1e2c455beac4a431b152590650fd15749cd91884936f5fc61a1692b49889" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089259/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089259", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7614-8fb8-81a755094f82" } R7TLQsxRKnM1H1SyduqitICEBVqDQJU3R9g/TZoYXtQCPwwNhzUGCsRaB5XRJMXnGxcsQSzE53lDo6wQhuRkCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: R7TLQsxRKnM1H1SyduqitICEBVqDQJU3R9g/TZoYXtQCPwwNhzUGCsRaB5XRJMXnGxcsQSzE53lDo6wQhuRkCA== {"files":[{"bytes":19137,"name":"index.html","sha256":"365244562f1712635fef69a55db8050bdc1a4b6b0f600b0c0f4f2845ea01ff6c"},{"bytes":8670,"name":"publication.md","sha256":"e927f587bffe3a0ae47494d4bb5d4df2b5e86ea8b30ad2acb24f2ee858522039"},{"bytes":8322,"name":"publication.txt","sha256":"65ddd0aff4961256b6100056d1665f1e64bde92d70e0347b9df60181d1c6f91c"},{"bytes":2893,"name":"manifest.json","sha256":"4d7ad36f2610014263310898fe13fc3b176cd7b645ae12c5530446a900098a24"},{"bytes":89,"name":"manifest.sig","sha256":"ddf3ea5804334152b38010847078bd75c49c5396a9b7fb18df80dd2efc0cd275"},{"bytes":227,"name":"manifest.sig.txt","sha256":"97019643084a8bc118df72556ac5ff0099f0889d40df9d1df27cfdcd02a36f8c"}],"publication_id":"OT-2026-000089260"} Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089260
OpenTechnical

OT-2026-000089260

Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
65ddd0aff4961256b6100056d1665f1e64bde92d70e0347b9df60181d1c6f91c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089260, “Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089260.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089260" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089260" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089260 Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089260 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089260 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089260 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089260", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1207 }, "figures": [], "files": [ { "bytes": 19137, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "365244562f1712635fef69a55db8050bdc1a4b6b0f600b0c0f4f2845ea01ff6c" }, { "bytes": 8670, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e927f587bffe3a0ae47494d4bb5d4df2b5e86ea8b30ad2acb24f2ee858522039" }, { "bytes": 8322, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "65ddd0aff4961256b6100056d1665f1e64bde92d70e0347b9df60181d1c6f91c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089260/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089260", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7126-aca4-cbb3a0a10f70" } zPi2MH3G122l6wjFMRsUYnVVmGQOIvGSwyUyUVqcydgdmqBBT23XPiXxR3KMpXC4Y4AjhFdXu2PUGvlaONLDAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: zPi2MH3G122l6wjFMRsUYnVVmGQOIvGSwyUyUVqcydgdmqBBT23XPiXxR3KMpXC4Y4AjhFdXu2PUGvlaONLDAQ== {"files":[{"bytes":18530,"name":"index.html","sha256":"4f08d584c5e0f44b36d9393b9515368a63d639f882f8b04d23161a17f0195097"},{"bytes":8138,"name":"publication.md","sha256":"620b87ef2b776819bbddc9e04de9669326f1f4c968a6d35841f1c4e69bfda855"},{"bytes":7789,"name":"publication.txt","sha256":"ba0f2bc65bd3f03e5b64ca7a6e11984edd3524a85aed6f9c54ef637e645428fa"},{"bytes":2888,"name":"manifest.json","sha256":"9297268bb34fc867b171da2527d584e7d8e221a1e38601ee3bbdfd96603e8a13"},{"bytes":89,"name":"manifest.sig","sha256":"cdea28387871464e2a379635b9048b97325a1ec514896bb44ae2933cd91d66ca"},{"bytes":227,"name":"manifest.sig.txt","sha256":"48125d15440ba7784c6feb58c9070b002c782d6faa2598af1048a35bc3e8351a"}],"publication_id":"OT-2026-000089261"} Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089261
OpenTechnical

OT-2026-000089261

Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
ba0f2bc65bd3f03e5b64ca7a6e11984edd3524a85aed6f9c54ef637e645428fa

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089261, “Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089261.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089261" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089261" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089261 Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089261 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089261 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089261 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089261", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1121 }, "figures": [], "files": [ { "bytes": 18530, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4f08d584c5e0f44b36d9393b9515368a63d639f882f8b04d23161a17f0195097" }, { "bytes": 8138, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "620b87ef2b776819bbddc9e04de9669326f1f4c968a6d35841f1c4e69bfda855" }, { "bytes": 7789, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ba0f2bc65bd3f03e5b64ca7a6e11984edd3524a85aed6f9c54ef637e645428fa" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089261/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089261", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7cfc-9739-b3adacbfebb7" } /mx1QrkNzMo4WadtAWpDTIYeBHaQp/lRtWa5V44ccZd8SNlaocJo/L516ZOOVUiRWKh28Bh4HWDeuVeHePhzCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: /mx1QrkNzMo4WadtAWpDTIYeBHaQp/lRtWa5V44ccZd8SNlaocJo/L516ZOOVUiRWKh28Bh4HWDeuVeHePhzCg== {"files":[{"bytes":19336,"name":"index.html","sha256":"b1b7dcc0600190512a770f6c4b3491e4619a961131b1ba3053d0d883b00b51fa"},{"bytes":8826,"name":"publication.md","sha256":"0a5b3c2831f0ba5272655faffd00ee98f555e2c20485dbd53ea2bf0e012d65f4"},{"bytes":8478,"name":"publication.txt","sha256":"04943f0a5619316f8c38fb288bb809a1831ea4f8ff660201cecfc24358c27097"},{"bytes":2893,"name":"manifest.json","sha256":"f113c95090b5756671baaae6bae81030c4bb54b646735e9ca7455ca20c356ca2"},{"bytes":89,"name":"manifest.sig","sha256":"c9067b50550a7165607ee7f369e3896d8f7e53399e3069b15685a18b99a801dc"},{"bytes":227,"name":"manifest.sig.txt","sha256":"bdf99372959ea87e6e7b97f89d65c9e1dc1434dd16555cb5c07452ab71a4c7c4"}],"publication_id":"OT-2026-000089262"} Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089262
OpenTechnical

OT-2026-000089262

Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
04943f0a5619316f8c38fb288bb809a1831ea4f8ff660201cecfc24358c27097

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089262, “Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089262.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089262" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089262" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089262 Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089262 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089262 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089262 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089262", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1227 }, "figures": [], "files": [ { "bytes": 19336, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b1b7dcc0600190512a770f6c4b3491e4619a961131b1ba3053d0d883b00b51fa" }, { "bytes": 8826, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0a5b3c2831f0ba5272655faffd00ee98f555e2c20485dbd53ea2bf0e012d65f4" }, { "bytes": 8478, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "04943f0a5619316f8c38fb288bb809a1831ea4f8ff660201cecfc24358c27097" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089262/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089262", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7eef-a9be-65c1daa88523" } z91GosHac41jBzUyH1bZRHOR+JXHFTeFetNu9dwl64RcuamQzip5v68kPxVi99jGA0bgflWTBOChHXKI5pfXCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: z91GosHac41jBzUyH1bZRHOR+JXHFTeFetNu9dwl64RcuamQzip5v68kPxVi99jGA0bgflWTBOChHXKI5pfXCw== {"files":[{"bytes":19083,"name":"index.html","sha256":"0cda0a4b33fa4fe9726530a02a4531106400a9a2612eec28bdf6804c99972904"},{"bytes":8616,"name":"publication.md","sha256":"98a542f8402f0ed9df62b0f7799ddfd281a194b8d7189cfaa153c30e78cd58bc"},{"bytes":8268,"name":"publication.txt","sha256":"62a7095d7646b7394471e9f9f4df302682ba1ae1100c4e08284c361856f1eb06"},{"bytes":2893,"name":"manifest.json","sha256":"78532fb0e70e37a10141b822a0fbcf0e2de885f4581cc0c9d3b961ce676e332a"},{"bytes":89,"name":"manifest.sig","sha256":"6d9c74fe8e0f426ed12525f11be4dca7fff83e1687368915e05b4f04ba19b139"},{"bytes":227,"name":"manifest.sig.txt","sha256":"593498458c9ed27f60d000364240368ad215829d1846fc0f8a292a7879e39fe2"}],"publication_id":"OT-2026-000089263"} Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089263
OpenTechnical

OT-2026-000089263

Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
62a7095d7646b7394471e9f9f4df302682ba1ae1100c4e08284c361856f1eb06

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089263, “Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089263.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089263" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089263" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089263 Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089263 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089263 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089263 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089263", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1192 }, "figures": [], "files": [ { "bytes": 19083, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0cda0a4b33fa4fe9726530a02a4531106400a9a2612eec28bdf6804c99972904" }, { "bytes": 8616, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "98a542f8402f0ed9df62b0f7799ddfd281a194b8d7189cfaa153c30e78cd58bc" }, { "bytes": 8268, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "62a7095d7646b7394471e9f9f4df302682ba1ae1100c4e08284c361856f1eb06" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089263/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089263", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7445-9699-0026d65de612" } Wlo1cCdXXNMNulzuurOlqacXM1LE2jvOVWd8FkaFXAErKDOCfkcWIGfrIoUg/AygOPvtfUBM/3o8XS+17YgsAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Wlo1cCdXXNMNulzuurOlqacXM1LE2jvOVWd8FkaFXAErKDOCfkcWIGfrIoUg/AygOPvtfUBM/3o8XS+17YgsAg== {"files":[{"bytes":18292,"name":"index.html","sha256":"098592227f172934a2a00baef280e4b7a82840a2d15b0c08e37e1cfa70c0d566"},{"bytes":7946,"name":"publication.md","sha256":"8fdec2f3310ae1b3d987eefbf291f6f94b368fb1089e352fa689f193cc548eb3"},{"bytes":7594,"name":"publication.txt","sha256":"afc33055e61e63372e52781368c04381edb1e389bbb6a9907013a06582479551"},{"bytes":2903,"name":"manifest.json","sha256":"ed14881200538bd651caa0bcdcc11e3ecf057f2ddf508e89e53eeae4bc93abb9"},{"bytes":89,"name":"manifest.sig","sha256":"e9a71a88b308d152beff6032e84a6bd9ce4acbb409203f7793b9ff04b93e6e6d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"56a9767663705d259ee9c7245cccc574dc9d101b00a872799590b73937ed0d2c"}],"publication_id":"OT-2026-000089264"} Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089264
OpenTechnical

OT-2026-000089264

Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
afc33055e61e63372e52781368c04381edb1e389bbb6a9907013a06582479551

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089264, “Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089264.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089264" title: "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089264" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089264 Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089264 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089264 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089264 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089264", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1084 }, "figures": [], "files": [ { "bytes": 18292, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "098592227f172934a2a00baef280e4b7a82840a2d15b0c08e37e1cfa70c0d566" }, { "bytes": 7946, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8fdec2f3310ae1b3d987eefbf291f6f94b368fb1089e352fa689f193cc548eb3" }, { "bytes": 7594, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "afc33055e61e63372e52781368c04381edb1e389bbb6a9907013a06582479551" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089264/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089264", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db00-7628-a1e9-573d4d2c1a9e" } Au3dKMeXEKXvMYyuqXLJXpuMmGooqtnFlvgXC6jg01fe9RUgu41sshyCgk6QM2jjRwmWbMBWIq5VPZdtCJZIDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Au3dKMeXEKXvMYyuqXLJXpuMmGooqtnFlvgXC6jg01fe9RUgu41sshyCgk6QM2jjRwmWbMBWIq5VPZdtCJZIDQ== {"files":[{"bytes":19098,"name":"index.html","sha256":"4b96fa3ac7e8379faad86f19067c24477a5b21626db87c9ef15ca681d543c5c3"},{"bytes":8634,"name":"publication.md","sha256":"19e98bac43919e49137b295155c7ddadc1573f3881740d4d0d32568f8a24a30a"},{"bytes":8283,"name":"publication.txt","sha256":"0f3cde69d8b9589dc82d7ca9b085f9d2cd9035212801465777e2de939d57a1d7"},{"bytes":2908,"name":"manifest.json","sha256":"27d3646bcc5af7bdd97a7514918e4d1f344f4c04aa2bf045768639bfd675db93"},{"bytes":89,"name":"manifest.sig","sha256":"617fe09c07183a2c049a2daf402c84ba3ef4c26b40a379b82dd610010a56e00b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d2bdd8821733977dd5535a081fdf6a1a0620b262f418ff18d9f64e316c0c943b"}],"publication_id":"OT-2026-000089265"} Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089265
OpenTechnical

OT-2026-000089265

Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
0f3cde69d8b9589dc82d7ca9b085f9d2cd9035212801465777e2de939d57a1d7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089265, “Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089265.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089265" title: "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089265" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089265 Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089265 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089265 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089265 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089265", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1190 }, "figures": [], "files": [ { "bytes": 19098, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4b96fa3ac7e8379faad86f19067c24477a5b21626db87c9ef15ca681d543c5c3" }, { "bytes": 8634, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "19e98bac43919e49137b295155c7ddadc1573f3881740d4d0d32568f8a24a30a" }, { "bytes": 8283, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0f3cde69d8b9589dc82d7ca9b085f9d2cd9035212801465777e2de939d57a1d7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089265/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089265", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7325-9eff-0e115634153f" } t04mxkiHwvooF3lwxqwx0MpQEcXwcG1t4m47KQrLPvo6Vox+LRmgPquEsrmusqUdGwiHku9AJYol//1Hg0IJBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: t04mxkiHwvooF3lwxqwx0MpQEcXwcG1t4m47KQrLPvo6Vox+LRmgPquEsrmusqUdGwiHku9AJYol//1Hg0IJBQ== {"files":[{"bytes":18845,"name":"index.html","sha256":"c8dceddd7435a0b3905c8b7aa9bc3e4150d24e0aafe13cc10da7aa81cbe2eb93"},{"bytes":8424,"name":"publication.md","sha256":"d0b355fd00e6a6f2adff250d9f6a1afbf99feb4bbb9a9d2e9c66dc4ac437d478"},{"bytes":8073,"name":"publication.txt","sha256":"e38e041c580618ba49fa205d2fca45f6c026184253ab12c6a95d6960d8f388c1"},{"bytes":2908,"name":"manifest.json","sha256":"276a07031c4d00657188c51079e8b271cd6eff9bcb0bfe92b58cea4476f1ea5d"},{"bytes":89,"name":"manifest.sig","sha256":"e6bc1d3ed9e2e84684100c5237dddc228159020931b71a014f68bcb4c6ef8256"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e5fd356036f589ebf3091f4d0a1fcfcca04faae8ae5827ebe09e06c44093755a"}],"publication_id":"OT-2026-000089266"} Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089266
OpenTechnical

OT-2026-000089266

Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e38e041c580618ba49fa205d2fca45f6c026184253ab12c6a95d6960d8f388c1

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089266, “Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089266.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089266" title: "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089266" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089266 Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089266 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089266 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089266 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089266", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1155 }, "figures": [], "files": [ { "bytes": 18845, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c8dceddd7435a0b3905c8b7aa9bc3e4150d24e0aafe13cc10da7aa81cbe2eb93" }, { "bytes": 8424, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d0b355fd00e6a6f2adff250d9f6a1afbf99feb4bbb9a9d2e9c66dc4ac437d478" }, { "bytes": 8073, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e38e041c580618ba49fa205d2fca45f6c026184253ab12c6a95d6960d8f388c1" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089266/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089266", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db00-7483-b97e-37494531fb69" } s1kYVWEA6mfssRx/1PBZfJjb0lJzBM/Fe2cv6NmPil291pKteaL+ioNfMD7qoQpDYz7DD+IAhLrHKSeXWyvADA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: s1kYVWEA6mfssRx/1PBZfJjb0lJzBM/Fe2cv6NmPil291pKteaL+ioNfMD7qoQpDYz7DD+IAhLrHKSeXWyvADA== {"files":[{"bytes":18292,"name":"index.html","sha256":"50b07fd21d1867479e4428053878c1efec69d81f80f7b9c477431e1d4200a88a"},{"bytes":7946,"name":"publication.md","sha256":"0b64a0fcb2f8ef0f61c830d9563575d1a3b7be896066d1630465205a6676b383"},{"bytes":7594,"name":"publication.txt","sha256":"ef8f260e3df6adf26453f7fd4c461270c385c7bc3adbd8f1e2aa1309c72125b8"},{"bytes":2903,"name":"manifest.json","sha256":"25325c496e9ea2904c5153367c3a135bfe4bdd76294040847f9b48749f491c56"},{"bytes":89,"name":"manifest.sig","sha256":"e54d89c4d8a39d5f10af6b4ecd4151f7e6fe690504d259c1df2718b5c459ca63"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c5d58d6d0889a38ce427d9d5ca52fbf63c2478d6baef12e098a1bc8ae3eb3135"}],"publication_id":"OT-2026-000089267"} Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089267
OpenTechnical

OT-2026-000089267

Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
ef8f260e3df6adf26453f7fd4c461270c385c7bc3adbd8f1e2aa1309c72125b8

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089267, “Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089267.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089267" title: "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089267" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089267 Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089267 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089267 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089267 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089267", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1084 }, "figures": [], "files": [ { "bytes": 18292, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "50b07fd21d1867479e4428053878c1efec69d81f80f7b9c477431e1d4200a88a" }, { "bytes": 7946, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0b64a0fcb2f8ef0f61c830d9563575d1a3b7be896066d1630465205a6676b383" }, { "bytes": 7594, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ef8f260e3df6adf26453f7fd4c461270c385c7bc3adbd8f1e2aa1309c72125b8" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089267/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089267", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-77fc-aa71-3a71717716f2" } 547O9GMe0BkK7a9gIvREnuIAn6iYTQHpP2e6W+L8ezbfqzdfej2dZInM+vXhWD50Tc3bByK/FsRFLv0bJhZ5DQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 547O9GMe0BkK7a9gIvREnuIAn6iYTQHpP2e6W+L8ezbfqzdfej2dZInM+vXhWD50Tc3bByK/FsRFLv0bJhZ5DQ== {"files":[{"bytes":19098,"name":"index.html","sha256":"3b5b06f4547fa1a8f5abc82803fc11153b3510528ff71b2ad6776e8db911535c"},{"bytes":8634,"name":"publication.md","sha256":"746f51a180b287aee9b0551c85224963343849ffbb8f248c0e91864d07edc73d"},{"bytes":8283,"name":"publication.txt","sha256":"25b964b35ab29fac85f9de40ed147612ddbface6db3d8259ef40882dd8a90608"},{"bytes":2908,"name":"manifest.json","sha256":"6c05f5f59367f559ed2967d54e35eae831b7fc806bcaa0c177c3db93ee89d302"},{"bytes":89,"name":"manifest.sig","sha256":"0924e67ffc511b03b1bdf66da335fd88dcc630ab14be2ec16bebdb72758d68d5"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ef61cd64eb5322ecd161a23a8cbdb663484d938953f13e0056d01b629a9ea439"}],"publication_id":"OT-2026-000089268"} Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089268
OpenTechnical

OT-2026-000089268

Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
25b964b35ab29fac85f9de40ed147612ddbface6db3d8259ef40882dd8a90608

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089268, “Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089268.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089268" title: "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089268" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089268 Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089268 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089268 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089268 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089268", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1190 }, "figures": [], "files": [ { "bytes": 19098, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3b5b06f4547fa1a8f5abc82803fc11153b3510528ff71b2ad6776e8db911535c" }, { "bytes": 8634, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "746f51a180b287aee9b0551c85224963343849ffbb8f248c0e91864d07edc73d" }, { "bytes": 8283, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "25b964b35ab29fac85f9de40ed147612ddbface6db3d8259ef40882dd8a90608" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089268/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089268", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-79e8-af8e-13ff0200f1c1" } rHD1FvVhHKrXdU1uwXFkyO3af9bZyez+2sCPOaNWWZj66xOhndu7QUSbhLg3IChy095b1MG8Mo1IzCsycnyrDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: rHD1FvVhHKrXdU1uwXFkyO3af9bZyez+2sCPOaNWWZj66xOhndu7QUSbhLg3IChy095b1MG8Mo1IzCsycnyrDA== {"files":[{"bytes":18845,"name":"index.html","sha256":"c6429591718e2479a8daa91889106077980b4f57aa0e3d37c8aa1ef9c542ca1b"},{"bytes":8424,"name":"publication.md","sha256":"9b8df00a409808e8d9bb63f7063dd2edeeff8d87b012e2412829b477fd816422"},{"bytes":8073,"name":"publication.txt","sha256":"7fd2cb053ed6dcb563a5a90d071cad0de2ba3321fc0e0f7e6eecfa75c323939c"},{"bytes":2908,"name":"manifest.json","sha256":"cc61b6575bd930f60e9539c9f24be242315c6d50bc717b795f4c16e1429268a0"},{"bytes":89,"name":"manifest.sig","sha256":"c8c39d23b59f54f1d5e529d30f1decc56701d442c332c005b87656f36525ee51"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8931e56282a13e3cfe4a2b71d0b3747429b67e19289396a3c835e59fb0da224b"}],"publication_id":"OT-2026-000089269"} Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089269
OpenTechnical

OT-2026-000089269

Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7fd2cb053ed6dcb563a5a90d071cad0de2ba3321fc0e0f7e6eecfa75c323939c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining two manifold outlets are plugged and carry no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089269, “Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089269.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089269" title: "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089269" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089269 Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089269 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the line between the plant vacuum connection and the distribution and reads the pressure of the whole circuit. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining two manifold outlets are plugged and carry no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089269 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089269 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one plant vacuum connection, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089269", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1155 }, "figures": [], "files": [ { "bytes": 18845, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c6429591718e2479a8daa91889106077980b4f57aa0e3d37c8aa1ef9c542ca1b" }, { "bytes": 8424, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9b8df00a409808e8d9bb63f7063dd2edeeff8d87b012e2412829b477fd816422" }, { "bytes": 8073, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7fd2cb053ed6dcb563a5a90d071cad0de2ba3321fc0e0f7e6eecfa75c323939c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089269/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089269", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, plant vacuum fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7304-a2c5-5f4e6ebb01ef" } btVkQP581HJUO4H5wiyUB9K/d9f5ZGbIVJ9FJPHz9J9Wd1/8Jb9+DuwP85+mJf8bUWuS3/t6WTNCbZG2f+kODw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: btVkQP581HJUO4H5wiyUB9K/d9f5ZGbIVJ9FJPHz9J9Wd1/8Jb9+DuwP85+mJf8bUWuS3/t6WTNCbZG2f+kODw== {"files":[{"bytes":18339,"name":"index.html","sha256":"a9dbb476cf955837391d233f27d91d75d2f7b9b6fe8ac1a3d9d4daeed4437087"},{"bytes":7934,"name":"publication.md","sha256":"714feca3d614e31dd0455c75ece09411b88f737a2f7b69e3e6a03d0ceded8f95"},{"bytes":7601,"name":"publication.txt","sha256":"1e2a1a9cc70aea597700f3d856eb885a34e250101cf0b82af3f8b5ac381da5d8"},{"bytes":2860,"name":"manifest.json","sha256":"2c9a72245eed49f691b42420ffdeb6db367fb64d53eec33d43de1483f99fd4eb"},{"bytes":89,"name":"manifest.sig","sha256":"2969ef8498d800b6f4f4966265c4a2b84779b27a8dbcb4c11f3e68b885aa9119"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7155fe4ed9ae20c3ca5f42d4adcca5323916a794944ed51f73d184bd9e4e1b69"}],"publication_id":"OT-2026-000089270"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089270
OpenTechnical

OT-2026-000089270

Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
1e2a1a9cc70aea597700f3d856eb885a34e250101cf0b82af3f8b5ac381da5d8

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089270, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089270.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089270" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089270" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089270 Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089270 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089270 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089270 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089270", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1094 }, "figures": [], "files": [ { "bytes": 18339, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a9dbb476cf955837391d233f27d91d75d2f7b9b6fe8ac1a3d9d4daeed4437087" }, { "bytes": 7934, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "714feca3d614e31dd0455c75ece09411b88f737a2f7b69e3e6a03d0ceded8f95" }, { "bytes": 7601, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1e2a1a9cc70aea597700f3d856eb885a34e250101cf0b82af3f8b5ac381da5d8" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089270/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089270", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-70df-9a55-dfda0ccf0368" } 5AknbuvmDvdlXYheEpF3YT17dJ7vPyc1ThSCg+KocvB9GHB/tMVylGZ+4IefAKDlZpbpDjbzSMCc3YtCnTe/BA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 5AknbuvmDvdlXYheEpF3YT17dJ7vPyc1ThSCg+KocvB9GHB/tMVylGZ+4IefAKDlZpbpDjbzSMCc3YtCnTe/BA== {"files":[{"bytes":19154,"name":"index.html","sha256":"b4787d3f828cfef22c9738e8db6bbdaca4282851d489e82fe933686f4e3866f6"},{"bytes":8635,"name":"publication.md","sha256":"1c62a8b603584495b1ce8b777b8c977d81af40ddd2ca1046092351739d5e1998"},{"bytes":8296,"name":"publication.txt","sha256":"673cda5e77e6a49780ac3c7f1e81c10b7c4e9b03d1cebd16b8d92d78123c6488"},{"bytes":2872,"name":"manifest.json","sha256":"3a55d4f5af52596cc761f8c39e7286e171b4c84c899de254cafc9a88ec41fbc1"},{"bytes":89,"name":"manifest.sig","sha256":"e4326c0796248e6c4ef39c2d85ee53df8273be0bff92c213d9ba0648c08382ea"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4d2f160f43ec9098cd41dc46a01f512f2ce223f5b32e7158fda4ab3ec2e59ee2"}],"publication_id":"OT-2026-000089271"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089271
OpenTechnical

OT-2026-000089271

Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
673cda5e77e6a49780ac3c7f1e81c10b7c4e9b03d1cebd16b8d92d78123c6488

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089271, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089271.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089271" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089271" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089271 Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089271 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089271 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089271 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089271", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1200 }, "figures": [], "files": [ { "bytes": 19154, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b4787d3f828cfef22c9738e8db6bbdaca4282851d489e82fe933686f4e3866f6" }, { "bytes": 8635, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1c62a8b603584495b1ce8b777b8c977d81af40ddd2ca1046092351739d5e1998" }, { "bytes": 8296, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "673cda5e77e6a49780ac3c7f1e81c10b7c4e9b03d1cebd16b8d92d78123c6488" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089271/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089271", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-73a2-ae31-da85690451d1" } 5bQQ9DgnePq6xQNfKmR0t3DIFeXtImtVBZAbcoe6lX+zN3SWVRnt+vm/qAwdkOiBf6yCLFn6D/aXtn9DXCHOCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 5bQQ9DgnePq6xQNfKmR0t3DIFeXtImtVBZAbcoe6lX+zN3SWVRnt+vm/qAwdkOiBf6yCLFn6D/aXtn9DXCHOCg== {"files":[{"bytes":18901,"name":"index.html","sha256":"5ff5023a0ca22dfbc842dc403c5cb41f51c4e4c287e04a0b21fcf1ac343f8c17"},{"bytes":8425,"name":"publication.md","sha256":"226685b973ae8a078159229cec1eee49b78016a7e8e9ad9206f101a367b19f34"},{"bytes":8086,"name":"publication.txt","sha256":"f5a09e6dbd0091016be27691df1bf72abda0225c834355680a23619d74c8cba3"},{"bytes":2872,"name":"manifest.json","sha256":"fefd77bec836d3d31725f8777e03dacb006022f980f23a50d3ac038d9479a430"},{"bytes":89,"name":"manifest.sig","sha256":"2d84a51439fc6001b888d878158b2f29d237018c718c2cbf2526e4d9784c9e66"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b744b47da6556a56b05ccbb182c86c4f2767c90342cbf7aac96b6086452bea31"}],"publication_id":"OT-2026-000089272"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089272
OpenTechnical

OT-2026-000089272

Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f5a09e6dbd0091016be27691df1bf72abda0225c834355680a23619d74c8cba3

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089272, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089272.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089272" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089272" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089272 Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089272 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089272 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089272 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089272", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1165 }, "figures": [], "files": [ { "bytes": 18901, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5ff5023a0ca22dfbc842dc403c5cb41f51c4e4c287e04a0b21fcf1ac343f8c17" }, { "bytes": 8425, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "226685b973ae8a078159229cec1eee49b78016a7e8e9ad9206f101a367b19f34" }, { "bytes": 8086, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f5a09e6dbd0091016be27691df1bf72abda0225c834355680a23619d74c8cba3" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089272/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089272", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7ca9-a7a6-58f818ddab45" } sZN5f+n0VxsB7ITvYGaHqq1tArhXhQfpzskKesIWW8ZopvKBfA4HWGfzotYFs0vgQHSSfjiFCIK24i1yk8qTCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: sZN5f+n0VxsB7ITvYGaHqq1tArhXhQfpzskKesIWW8ZopvKBfA4HWGfzotYFs0vgQHSSfjiFCIK24i1yk8qTCg== {"files":[{"bytes":18340,"name":"index.html","sha256":"f646dd26a1814694467370b64a891323ebbdc840b0464f6a1b950838254956d3"},{"bytes":7935,"name":"publication.md","sha256":"30e873f56a00d4fc58c36b63d0f52fa65ca2a4a78dced15936e84aa5f887f6e4"},{"bytes":7602,"name":"publication.txt","sha256":"ecd761fda505b412f31e2e3b03de6206ab224e5fba16ba66bd84043a12ee4a04"},{"bytes":2860,"name":"manifest.json","sha256":"7d03433f7298d4bbe7846b07e2cd938883889d23f82d5086c2fa6df8b3312551"},{"bytes":89,"name":"manifest.sig","sha256":"b16ccee16fe9886d6f8332306e4ac0299e02459cdea2d2aba9ef7a091318b36e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"29ac33668a4b9b853fda71e64c0f2c9ce46cd905cc9512cbd820a61ab1ffce69"}],"publication_id":"OT-2026-000089273"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089273
OpenTechnical

OT-2026-000089273

Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
ecd761fda505b412f31e2e3b03de6206ab224e5fba16ba66bd84043a12ee4a04

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089273, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089273.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089273" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089273" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089273 Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089273 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089273 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089273 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089273", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1094 }, "figures": [], "files": [ { "bytes": 18340, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f646dd26a1814694467370b64a891323ebbdc840b0464f6a1b950838254956d3" }, { "bytes": 7935, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "30e873f56a00d4fc58c36b63d0f52fa65ca2a4a78dced15936e84aa5f887f6e4" }, { "bytes": 7602, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ecd761fda505b412f31e2e3b03de6206ab224e5fba16ba66bd84043a12ee4a04" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089273/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089273", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7374-9c3c-c2df03774e51" } nMrEkL1w+tervtSTQNvv5yMeV8iIpzk02kdB9qIqji6/q41hMuH2vr9mdHefuTJnYbz+m6afPbDVeqTPKkt3Cg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: nMrEkL1w+tervtSTQNvv5yMeV8iIpzk02kdB9qIqji6/q41hMuH2vr9mdHefuTJnYbz+m6afPbDVeqTPKkt3Cg== {"files":[{"bytes":19155,"name":"index.html","sha256":"0e492c95d4e6722fbad26f9b0469ac3177d5142ae117b117be57aa47df9145f9"},{"bytes":8636,"name":"publication.md","sha256":"d38d521aa7dac2df70cb84532b98045a44c1d2062111c046a598159accbb8fac"},{"bytes":8297,"name":"publication.txt","sha256":"e5a1b33208d75901e514bcf2b99a7aae971335b78836b064ce02594e489db455"},{"bytes":2872,"name":"manifest.json","sha256":"5f83292c75fa2fda65bf084baf54922fd9bea39913811872143055feb42aa8d3"},{"bytes":89,"name":"manifest.sig","sha256":"b1301ad274370a17c1bc33bbd66ded9c5c4d302319593866c6a1070d30697d64"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f913a1f97a16ed3d7a4f3f5a989a2377f1a3fcc9bc5deac5f75436e3d5877af5"}],"publication_id":"OT-2026-000089274"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089274
OpenTechnical

OT-2026-000089274

Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e5a1b33208d75901e514bcf2b99a7aae971335b78836b064ce02594e489db455

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089274, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089274.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089274" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089274" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089274 Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089274 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089274 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089274 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089274", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1200 }, "figures": [], "files": [ { "bytes": 19155, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0e492c95d4e6722fbad26f9b0469ac3177d5142ae117b117be57aa47df9145f9" }, { "bytes": 8636, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d38d521aa7dac2df70cb84532b98045a44c1d2062111c046a598159accbb8fac" }, { "bytes": 8297, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e5a1b33208d75901e514bcf2b99a7aae971335b78836b064ce02594e489db455" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089274/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089274", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7378-b796-e9153f131bbb" } ouw7ha2/VMYvMR5FJfEMiY7FuOMbyIzV5XSO85Xb86hvmqgNTttVEvRbIKJ9WLKn0maBXQoih1O5hLEvqfcvCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ouw7ha2/VMYvMR5FJfEMiY7FuOMbyIzV5XSO85Xb86hvmqgNTttVEvRbIKJ9WLKn0maBXQoih1O5hLEvqfcvCw== {"files":[{"bytes":18902,"name":"index.html","sha256":"1bf75f52b533607726ef75eee2052a7d67b5e94631897f8ee540b4e2ee60866a"},{"bytes":8426,"name":"publication.md","sha256":"7c72066b72e267be789a4e35f461a2740cfc14c86c833165a885509f0f8ed9ce"},{"bytes":8087,"name":"publication.txt","sha256":"8bb0f9f1ee59652e0e01a67cb2ea0d4418945b1a1c70b73c60f08b9eae6da43d"},{"bytes":2872,"name":"manifest.json","sha256":"14809ed9c8ba60dd9c577700c73f056518953c8355d8e86831d9cd8f4204858e"},{"bytes":89,"name":"manifest.sig","sha256":"4f7ce108080ba4fe5f6ed13be9c07a2de5144c6148ee99b1260822da98583c76"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1f506c52e157ca4ea11ab8e0a0c0f780dbbbb143fa297b664f041fc7cbf7936e"}],"publication_id":"OT-2026-000089275"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089275
OpenTechnical

OT-2026-000089275

Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8bb0f9f1ee59652e0e01a67cb2ea0d4418945b1a1c70b73c60f08b9eae6da43d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089275, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089275.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089275" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089275" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089275 Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089275 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089275 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089275 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089275", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1165 }, "figures": [], "files": [ { "bytes": 18902, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1bf75f52b533607726ef75eee2052a7d67b5e94631897f8ee540b4e2ee60866a" }, { "bytes": 8426, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7c72066b72e267be789a4e35f461a2740cfc14c86c833165a885509f0f8ed9ce" }, { "bytes": 8087, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8bb0f9f1ee59652e0e01a67cb2ea0d4418945b1a1c70b73c60f08b9eae6da43d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089275/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089275", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7e28-81a5-587ce5fa484c" } mrFU6ZAS6J/rEmbc/PqqNM6ecB+qbIdxBnQ89uhn1/dpRyjKDA19XqCFsYrq4x6LGmpJC8s3PCZRDasbiA+QCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: mrFU6ZAS6J/rEmbc/PqqNM6ecB+qbIdxBnQ89uhn1/dpRyjKDA19XqCFsYrq4x6LGmpJC8s3PCZRDasbiA+QCQ== {"files":[{"bytes":18344,"name":"index.html","sha256":"196dc8a7ce0f0a72f7dab58869c201fbd552afaf7761798359f10541053f9862"},{"bytes":7939,"name":"publication.md","sha256":"d21b5f061cf919089ec6526798735f1a87979aba148b8f7d71f364702a0d1af0"},{"bytes":7606,"name":"publication.txt","sha256":"21e97108b661e2e03ee9a250bdf06eaa341b233807f515e9b1194484053c6eb6"},{"bytes":2860,"name":"manifest.json","sha256":"72096999ebbf178bff43e90e14ef8c6a883672aae73043f1041cb0e717450b18"},{"bytes":89,"name":"manifest.sig","sha256":"9d499d2dd61d677c70813fe06b4b6a415080bf767c27f1b96b839d19f0827589"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2826d318c6fdfd73166018aee12e282ca97ffd7e1c46193329dbda9d95ab8e10"}],"publication_id":"OT-2026-000089276"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089276
OpenTechnical

OT-2026-000089276

Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
21e97108b661e2e03ee9a250bdf06eaa341b233807f515e9b1194484053c6eb6

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089276, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089276.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089276" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089276" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089276 Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089276 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089276 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089276 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089276", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1094 }, "figures": [], "files": [ { "bytes": 18344, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "196dc8a7ce0f0a72f7dab58869c201fbd552afaf7761798359f10541053f9862" }, { "bytes": 7939, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d21b5f061cf919089ec6526798735f1a87979aba148b8f7d71f364702a0d1af0" }, { "bytes": 7606, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "21e97108b661e2e03ee9a250bdf06eaa341b233807f515e9b1194484053c6eb6" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089276/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089276", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-748d-a2bb-808a6c0e1141" } j8MvCmYT+Q1HOacrO7XVoB0rsRuJU6vxnehS1gkAPKqIQU5xH56Dn/m9SXkmTiQxF+th3pwOGwrUw1hJwpIBCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: j8MvCmYT+Q1HOacrO7XVoB0rsRuJU6vxnehS1gkAPKqIQU5xH56Dn/m9SXkmTiQxF+th3pwOGwrUw1hJwpIBCQ== {"files":[{"bytes":19159,"name":"index.html","sha256":"23f10e299f8294c0076a1514d0ed548b7ad38a669dd6fb15af6bb941b2216804"},{"bytes":8640,"name":"publication.md","sha256":"a189f66ac8dbdb52c53523a0b9f9e2d721497e4c84faa938ad5bc8f19a9a7286"},{"bytes":8301,"name":"publication.txt","sha256":"2ca4a5e168735ce2b6b22618046e203e33273fe0ea45d6e0eb4ba79cec1f0f28"},{"bytes":2872,"name":"manifest.json","sha256":"874b9c01a538bf857eadbd8c8380b3902a1a344271f43b1260bac9ec64f17dcc"},{"bytes":89,"name":"manifest.sig","sha256":"1f3c2be6d956ca241518d81b3b7de50e6dc89ec54070b198a5048dba1357a5b2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3f6f5b2ebcccda74154c4ac2dd7caafa73fe10c6a99d070a01410033f0ba8f9e"}],"publication_id":"OT-2026-000089277"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089277
OpenTechnical

OT-2026-000089277

Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
2ca4a5e168735ce2b6b22618046e203e33273fe0ea45d6e0eb4ba79cec1f0f28

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089277, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089277.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089277" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089277" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089277 Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089277 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089277 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089277 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089277", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1200 }, "figures": [], "files": [ { "bytes": 19159, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "23f10e299f8294c0076a1514d0ed548b7ad38a669dd6fb15af6bb941b2216804" }, { "bytes": 8640, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a189f66ac8dbdb52c53523a0b9f9e2d721497e4c84faa938ad5bc8f19a9a7286" }, { "bytes": 8301, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2ca4a5e168735ce2b6b22618046e203e33273fe0ea45d6e0eb4ba79cec1f0f28" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089277/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089277", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-706c-b428-f1a73a26dadf" } T9TJqqzCJm5fId73kwSWAwx4CcoQsncvzgWwiXd8M4VU7HLGfh/w35taO8L2n4Lf2nrVcD/WUqL06ZF85oz+Bw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: T9TJqqzCJm5fId73kwSWAwx4CcoQsncvzgWwiXd8M4VU7HLGfh/w35taO8L2n4Lf2nrVcD/WUqL06ZF85oz+Bw== {"files":[{"bytes":18906,"name":"index.html","sha256":"8e923a3a115e914657293f0ef08fc3323ea8bf1d9559a228502c95d75118a4e3"},{"bytes":8430,"name":"publication.md","sha256":"b712520c33fc6cfef37ad06c38f78e6c9239c46ad691463144c6cf69f503f2a6"},{"bytes":8091,"name":"publication.txt","sha256":"7b36545e84a8a93653333f453d576e36657592a3de178044f150a5b1344b9e63"},{"bytes":2872,"name":"manifest.json","sha256":"4d46972f5dfa7f257c71cf0e44c4f74a6f21dc1c4393db6ec427899270663184"},{"bytes":89,"name":"manifest.sig","sha256":"443de41bf864dee4f07d750150a4d436d5d06801fe3b603be867dc866737af66"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b1ce0f60d330859ce8fc8071319f20f91579051e7ec682267cab50ac04dc0a3f"}],"publication_id":"OT-2026-000089278"} Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089278
OpenTechnical

OT-2026-000089278

Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7b36545e84a8a93653333f453d576e36657592a3de178044f150a5b1344b9e63

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089278, “Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089278.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089278" title: "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089278" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089278 Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089278 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of four follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089278 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089278 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four bellows cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089278", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1165 }, "figures": [], "files": [ { "bytes": 18906, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8e923a3a115e914657293f0ef08fc3323ea8bf1d9559a228502c95d75118a4e3" }, { "bytes": 8430, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b712520c33fc6cfef37ad06c38f78e6c9239c46ad691463144c6cf69f503f2a6" }, { "bytes": 8091, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7b36545e84a8a93653333f453d576e36657592a3de178044f150a5b1344b9e63" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089278/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089278", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four bellows cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-719f-8b31-3dba39bd922d" } oT4yaND6ZkJHO57Ru9bPvlY6wB/NXHpiLCel0/cfvHpAcluCRxtJ8SiuqDMkIEP4EOZjwWFF9T6ks6zSuSS3BQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: oT4yaND6ZkJHO57Ru9bPvlY6wB/NXHpiLCel0/cfvHpAcluCRxtJ8SiuqDMkIEP4EOZjwWFF9T6ks6zSuSS3BQ== {"files":[{"bytes":18525,"name":"index.html","sha256":"8b1b094316007d9d0c6a045603a6a5af684269ba49367632b26d07624c029f8f"},{"bytes":8090,"name":"publication.md","sha256":"9e22c117cb238c72e423edceda82e756e7470eade438b49158632c3323896b50"},{"bytes":7768,"name":"publication.txt","sha256":"b0cd59a3a9b19dc2119222e8fce4c6817eb2279c2978ae63efdd6030c15ef768"},{"bytes":2837,"name":"manifest.json","sha256":"0b2151533c52fb20bda35e07743c01998fd36c4243fced93a4e86577b2d2bf4c"},{"bytes":89,"name":"manifest.sig","sha256":"fae5da3b51873e89e2606c8e6932dfad8be05c1fb354ca15e5fb97ef688be9d0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7155e49b1f57e99db0df6b92f1911fa3b9eebe1092bcc85cc0b76f1e2fd0098e"}],"publication_id":"OT-2026-000089279"} Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089279
OpenTechnical

OT-2026-000089279

Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
b0cd59a3a9b19dc2119222e8fce4c6817eb2279c2978ae63efdd6030c15ef768

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089279, “Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089279.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089279" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089279" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089279 Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089279 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089279 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089279 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089279", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1134 }, "figures": [], "files": [ { "bytes": 18525, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8b1b094316007d9d0c6a045603a6a5af684269ba49367632b26d07624c029f8f" }, { "bytes": 8090, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9e22c117cb238c72e423edceda82e756e7470eade438b49158632c3323896b50" }, { "bytes": 7768, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b0cd59a3a9b19dc2119222e8fce4c6817eb2279c2978ae63efdd6030c15ef768" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089279/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089279", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7c7b-9bcb-dccbfdc3bd1d" } yKjdGRM5H1cmQ+Hkw4JHTu7jWLsXvexHYedpvvitdMBhEnH099P3L2Y9PqTUJaT4vBOFI9oV+6HD3S7ScrhfCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: yKjdGRM5H1cmQ+Hkw4JHTu7jWLsXvexHYedpvvitdMBhEnH099P3L2Y9PqTUJaT4vBOFI9oV+6HD3S7ScrhfCg== {"files":[{"bytes":19340,"name":"index.html","sha256":"1e54ca1ec957030d2ed4af1cee7d809f0c3abf375ab11415e08eeee7411dcc33"},{"bytes":8791,"name":"publication.md","sha256":"bb18a2c6f5d02a263406970bd44e1c13d6d3646f2e931efcfa83b30ef84b5852"},{"bytes":8463,"name":"publication.txt","sha256":"a881376b2edc85b9d73027364b2498ec9be6b1c28ebdd5d8fae25e6ba3ad7240"},{"bytes":2849,"name":"manifest.json","sha256":"5b00af109111dd58eb3e94a02ae50317385607fc966f5d5933db6e2575ebeb4b"},{"bytes":89,"name":"manifest.sig","sha256":"e7faa3f60d68f64edd3c5f15468bc924e76ea10adbdb037b6acd25c5410f0379"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c1b3f1d51f3eb8286bb47f72411efec85a09e3c8204ef38a063a549841d8285b"}],"publication_id":"OT-2026-000089280"} Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089280
OpenTechnical

OT-2026-000089280

Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a881376b2edc85b9d73027364b2498ec9be6b1c28ebdd5d8fae25e6ba3ad7240

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089280, “Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089280.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089280" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089280" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089280 Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089280 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089280 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089280 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089280", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1240 }, "figures": [], "files": [ { "bytes": 19340, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1e54ca1ec957030d2ed4af1cee7d809f0c3abf375ab11415e08eeee7411dcc33" }, { "bytes": 8791, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "bb18a2c6f5d02a263406970bd44e1c13d6d3646f2e931efcfa83b30ef84b5852" }, { "bytes": 8463, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a881376b2edc85b9d73027364b2498ec9be6b1c28ebdd5d8fae25e6ba3ad7240" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089280/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089280", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7c32-8808-b91e465db37d" } aSOSLvXVUt+X1FRYRrlalbrxw0/cikvUrX4Qn9VhsaoTcBv5T2Fp1Q7pvi3PwBPSU/VbybTB+cewd++nJaOLBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: aSOSLvXVUt+X1FRYRrlalbrxw0/cikvUrX4Qn9VhsaoTcBv5T2Fp1Q7pvi3PwBPSU/VbybTB+cewd++nJaOLBA== {"files":[{"bytes":19087,"name":"index.html","sha256":"a1d877b40e746c3d5f74b3d03c9ed03e96e4a6334015f678db65d17ec3c62b97"},{"bytes":8581,"name":"publication.md","sha256":"fe4b17e8de660039c70ea7e67ad2c09069523f8250054f93d4a05b8f3c022a85"},{"bytes":8253,"name":"publication.txt","sha256":"8daaf8a6793dadcbf0b2bc22029ad3ff7293a4cb4710f7d9741cc26a805833ac"},{"bytes":2849,"name":"manifest.json","sha256":"934ba54bb203f3c5a18ca657c1c035ce7dcf6363bf2e0af36d9701abce43f263"},{"bytes":89,"name":"manifest.sig","sha256":"be1a8b152e2f2961a3e7b4371cbb30f0aa2dcc69f4a9c7e96a7f399bf91583b3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"857b3faa905f1d48f299d4398ce6e14e52176b401ecb6c38af6b6ff6c9a96f8b"}],"publication_id":"OT-2026-000089281"} Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089281
OpenTechnical

OT-2026-000089281

Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8daaf8a6793dadcbf0b2bc22029ad3ff7293a4cb4710f7d9741cc26a805833ac

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089281, “Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089281.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089281" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089281" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089281 Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089281 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089281 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089281 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089281", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1205 }, "figures": [], "files": [ { "bytes": 19087, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a1d877b40e746c3d5f74b3d03c9ed03e96e4a6334015f678db65d17ec3c62b97" }, { "bytes": 8581, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fe4b17e8de660039c70ea7e67ad2c09069523f8250054f93d4a05b8f3c022a85" }, { "bytes": 8253, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8daaf8a6793dadcbf0b2bc22029ad3ff7293a4cb4710f7d9741cc26a805833ac" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089281/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089281", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7fbc-9692-022154f0b549" } C4ChDETDlnezjPwny2Xasm3N6YrU9Rn0CETRLsEgtgBclqd0lLAP+mCLHSDD9xQE/IMjMsv8rIzj84xQdrqjDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: C4ChDETDlnezjPwny2Xasm3N6YrU9Rn0CETRLsEgtgBclqd0lLAP+mCLHSDD9xQE/IMjMsv8rIzj84xQdrqjDw== {"files":[{"bytes":18471,"name":"index.html","sha256":"dc749cb36d4d4ea48b4eb45aff1d648e5b051dee7fab9de6eec87c39dcb0a285"},{"bytes":8036,"name":"publication.md","sha256":"d5ffa161a34d12c162b9c139c17b9096020aee6ba0f79bbac3f9c989ffdb0927"},{"bytes":7714,"name":"publication.txt","sha256":"827e1d727e476c20790d0984dc633361f9c65c6a16fb4572bc6711b355fbc270"},{"bytes":2837,"name":"manifest.json","sha256":"bacb804f51a3f14af96e7c21f35b07f115737bac7f4d6124ec8c5c6929b11215"},{"bytes":89,"name":"manifest.sig","sha256":"6cc7f50ceb36ec16e7071a757472cb0740ea8056ee3c6cfc4e00982ad105535c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"122eed8e451b2e82344b21a1fe40d93357e4a024c1c4c3de9692e70a35486767"}],"publication_id":"OT-2026-000089282"} Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089282
OpenTechnical

OT-2026-000089282

Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
827e1d727e476c20790d0984dc633361f9c65c6a16fb4572bc6711b355fbc270

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089282, “Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089282.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089282" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089282" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089282 Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089282 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089282 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089282 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089282", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1119 }, "figures": [], "files": [ { "bytes": 18471, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "dc749cb36d4d4ea48b4eb45aff1d648e5b051dee7fab9de6eec87c39dcb0a285" }, { "bytes": 8036, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d5ffa161a34d12c162b9c139c17b9096020aee6ba0f79bbac3f9c989ffdb0927" }, { "bytes": 7714, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "827e1d727e476c20790d0984dc633361f9c65c6a16fb4572bc6711b355fbc270" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089282/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089282", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7c45-b626-dda8e4d50df5" } MEHNiCevljkMD7EMO933wVedhB9zQuZTnwTQ3kj+iOI9NrHo7IkyGf244YF8Rlaetv9DeNG0RxM+IWttp8y3BQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: MEHNiCevljkMD7EMO933wVedhB9zQuZTnwTQ3kj+iOI9NrHo7IkyGf244YF8Rlaetv9DeNG0RxM+IWttp8y3BQ== {"files":[{"bytes":19286,"name":"index.html","sha256":"148c49f5e798afa58cca0720769a8b50a83583eeb8efc7fcc8bcfdd187c8d917"},{"bytes":8737,"name":"publication.md","sha256":"bc7c68a72505d7750ec4c28d177fd7eedc39242027916bd9f4470143857687f5"},{"bytes":8409,"name":"publication.txt","sha256":"063b16c39edb0da5438a703bac4c60c001d8223abe8e488dfac60a6c6c96518b"},{"bytes":2849,"name":"manifest.json","sha256":"517e081c178ca07df18ea748c2bee0ab2d44aca6a0599fcfec2594b40f89b4a7"},{"bytes":89,"name":"manifest.sig","sha256":"24809d7cf56a950c20986861f03de18dc7e80083e6b41aad119ba0f0b0d39ecd"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9389c07ea52bc910292ed9656a2c27467915c96b96b8b1df1b41030dd7926f8e"}],"publication_id":"OT-2026-000089283"} Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089283
OpenTechnical

OT-2026-000089283

Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
063b16c39edb0da5438a703bac4c60c001d8223abe8e488dfac60a6c6c96518b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089283, “Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089283.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089283" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089283" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089283 Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089283 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089283 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089283 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089283", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1225 }, "figures": [], "files": [ { "bytes": 19286, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "148c49f5e798afa58cca0720769a8b50a83583eeb8efc7fcc8bcfdd187c8d917" }, { "bytes": 8737, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "bc7c68a72505d7750ec4c28d177fd7eedc39242027916bd9f4470143857687f5" }, { "bytes": 8409, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "063b16c39edb0da5438a703bac4c60c001d8223abe8e488dfac60a6c6c96518b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089283/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089283", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7427-8e1a-0c96ff9369f0" } PkSBOcYTHcYEUhN0J55o+uoQwN12SWzSIHLkQTWM+NpFLxbIzDHJxC66mNlU1KkweMrN0rRq7OJlWl8NWPztCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: PkSBOcYTHcYEUhN0J55o+uoQwN12SWzSIHLkQTWM+NpFLxbIzDHJxC66mNlU1KkweMrN0rRq7OJlWl8NWPztCA== {"files":[{"bytes":19033,"name":"index.html","sha256":"2d1db0415a2f79fe494e9ec768dcf9c634823e8c00d726ce60cfa82a10ebc119"},{"bytes":8527,"name":"publication.md","sha256":"fe66eb990b4f2832c12d4b50760a546d9eb380302e266059e6bed7ffdc660dec"},{"bytes":8199,"name":"publication.txt","sha256":"a96efbcb59106f3dcceae3568f90a2ee9cf7877e82a3e8146680eb8d9484c2d1"},{"bytes":2849,"name":"manifest.json","sha256":"6df1d5df5d5bcafded942f8bf53248dcbd0c906fbbc3b6f6698a2a97f3448dde"},{"bytes":89,"name":"manifest.sig","sha256":"b95fd67b5e1971ec169d6d685d86745a9baecdd0bbd0a5275860756dc47f8291"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d008abbe998ad51a4cb2edb8cb5866c2a9420afca5f90eaab9dbf64d938cab2c"}],"publication_id":"OT-2026-000089284"} Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089284
OpenTechnical

OT-2026-000089284

Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a96efbcb59106f3dcceae3568f90a2ee9cf7877e82a3e8146680eb8d9484c2d1

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089284, “Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089284.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089284" title: "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089284" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089284 Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089284 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089284 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089284 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089284", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1190 }, "figures": [], "files": [ { "bytes": 19033, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2d1db0415a2f79fe494e9ec768dcf9c634823e8c00d726ce60cfa82a10ebc119" }, { "bytes": 8527, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fe66eb990b4f2832c12d4b50760a546d9eb380302e266059e6bed7ffdc660dec" }, { "bytes": 8199, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a96efbcb59106f3dcceae3568f90a2ee9cf7877e82a3e8146680eb8d9484c2d1" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089284/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089284", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7fe5-bfdb-dbb795dca548" } vOM28TkiFWT1b3/iSaBgiaWKKE+2+kVyleNmTdMg0Fbwx0aoWW6KGFNvARRVdDKN5TE4CaniGNx0aha8Pxu8AA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: vOM28TkiFWT1b3/iSaBgiaWKKE+2+kVyleNmTdMg0Fbwx0aoWW6KGFNvARRVdDKN5TE4CaniGNx0aha8Pxu8AA== {"files":[{"bytes":18233,"name":"index.html","sha256":"6353e7fe966e6349d6b399d41e7a52d698d82702bb6a0e6f2dea491bb22c7623"},{"bytes":7844,"name":"publication.md","sha256":"78558aa9fd20dde17357183078074ff42695bcfbf8c5e3d4136511dd513208f5"},{"bytes":7519,"name":"publication.txt","sha256":"39f915360168925ef5c9658591af6c85bb2b222ddc2fd228dfed674ba9ca1c34"},{"bytes":2852,"name":"manifest.json","sha256":"7c8b5010d36d3b433f41e73e122ac902c9a18c4b0b3e3d46a176962aeb5b88d9"},{"bytes":89,"name":"manifest.sig","sha256":"1240ea630da711d41d21a97482f4e8eb36951f41059b257c0d0e2b85b734828d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ba254327c4fa5705da3ed3e07f1617462543d373cf51b9b83b1fe1653e6fe70b"}],"publication_id":"OT-2026-000089285"} Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089285
OpenTechnical

OT-2026-000089285

Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
39f915360168925ef5c9658591af6c85bb2b222ddc2fd228dfed674ba9ca1c34

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089285, “Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089285.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089285" title: "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089285" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089285 Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089285 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089285 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089285 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089285", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1082 }, "figures": [], "files": [ { "bytes": 18233, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6353e7fe966e6349d6b399d41e7a52d698d82702bb6a0e6f2dea491bb22c7623" }, { "bytes": 7844, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "78558aa9fd20dde17357183078074ff42695bcfbf8c5e3d4136511dd513208f5" }, { "bytes": 7519, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "39f915360168925ef5c9658591af6c85bb2b222ddc2fd228dfed674ba9ca1c34" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089285/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089285", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7579-9e06-83955edbd68f" } dgV5YCD/tb07BVCPB/3f/7yffdSiD6c3aXg4ysqyd6ys0DwBffmeYvhQnc2vLSmaYWU1dCpkwFr8SeNMBZDzDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: dgV5YCD/tb07BVCPB/3f/7yffdSiD6c3aXg4ysqyd6ys0DwBffmeYvhQnc2vLSmaYWU1dCpkwFr8SeNMBZDzDg== {"files":[{"bytes":19048,"name":"index.html","sha256":"e098682f227399a6739aebe420bf2c74d0ac4963a607be3d8599fe6a3f99c32b"},{"bytes":8545,"name":"publication.md","sha256":"854c8007aec3c55e28601854bde782d0af70837c1776b6bf7e7472832ed1cb02"},{"bytes":8214,"name":"publication.txt","sha256":"520735f45e77f74692ea271131da35b6a8073459d79d23b4f8c96ae3873eae3d"},{"bytes":2864,"name":"manifest.json","sha256":"fbbe3e31cf3f5b466f6c9b8e368c0023e1a44e5fcc849496e1b9c953a734ac26"},{"bytes":89,"name":"manifest.sig","sha256":"76ae4e7014bcf438ea841bde123da8abd356717ec1ddc8d0785cb4f07feee8d8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"23bd0e6667feb3158f6628aa4ba577b78e44a6993047b0d54842f9a314c15030"}],"publication_id":"OT-2026-000089286"} Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089286
OpenTechnical

OT-2026-000089286

Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
520735f45e77f74692ea271131da35b6a8073459d79d23b4f8c96ae3873eae3d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089286, “Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089286.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089286" title: "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089286" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089286 Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089286 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089286 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089286 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089286", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1188 }, "figures": [], "files": [ { "bytes": 19048, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "e098682f227399a6739aebe420bf2c74d0ac4963a607be3d8599fe6a3f99c32b" }, { "bytes": 8545, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "854c8007aec3c55e28601854bde782d0af70837c1776b6bf7e7472832ed1cb02" }, { "bytes": 8214, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "520735f45e77f74692ea271131da35b6a8073459d79d23b4f8c96ae3873eae3d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089286/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089286", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-777a-8015-37cbf418115f" } pcxJz7aApGk6CH+wZsYaW4Xfal1D51M0NgVV8wPYi1V+tEfRg5OeOZE3YAfFqH28fbTYiBVceg1BYCN1OzoyDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: pcxJz7aApGk6CH+wZsYaW4Xfal1D51M0NgVV8wPYi1V+tEfRg5OeOZE3YAfFqH28fbTYiBVceg1BYCN1OzoyDQ== {"files":[{"bytes":18795,"name":"index.html","sha256":"9eae0585b5ef798c26dc283aeb477e0a7cdeba0694709735b2c64cef5dc093d6"},{"bytes":8335,"name":"publication.md","sha256":"af4a3879fd83e117cced23ae9d13be2d34c4e0caa7604d8b5abcecb835e5c1ea"},{"bytes":8004,"name":"publication.txt","sha256":"fe9deafcd174e4c8f2ed127ad4e05dae199bbc2c8aaf3c7e3d80e7b3f3c05c53"},{"bytes":2864,"name":"manifest.json","sha256":"5c0e21664745c6f6ca2c90514e60308cd62da2a684311965f4b46e2e50ad337b"},{"bytes":89,"name":"manifest.sig","sha256":"468c8d4f42bda87df5c6aca25e8e43d3ad67cb89d16d847574cb5ab4e63301eb"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9c94f2b1729b0af2d242ddaf2183f26360d23d0d73742e16e08d65f9910f97bd"}],"publication_id":"OT-2026-000089287"} Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089287
OpenTechnical

OT-2026-000089287

Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
fe9deafcd174e4c8f2ed127ad4e05dae199bbc2c8aaf3c7e3d80e7b3f3c05c53

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089287, “Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089287.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089287" title: "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089287" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089287 Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089287 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089287 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089287 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089287", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1153 }, "figures": [], "files": [ { "bytes": 18795, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9eae0585b5ef798c26dc283aeb477e0a7cdeba0694709735b2c64cef5dc093d6" }, { "bytes": 8335, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "af4a3879fd83e117cced23ae9d13be2d34c4e0caa7604d8b5abcecb835e5c1ea" }, { "bytes": 8004, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fe9deafcd174e4c8f2ed127ad4e05dae199bbc2c8aaf3c7e3d80e7b3f3c05c53" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089287/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089287", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7527-ac48-bbec59f02b1b" } 1Yg9YMKCRaY7QZYeEDZr1mqDF+8Zl9LGHTcrU9PWIQtaQC62nvY1LrkcGBQfgfGBzp9dR5Lpn/NcjF5bFMSWAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 1Yg9YMKCRaY7QZYeEDZr1mqDF+8Zl9LGHTcrU9PWIQtaQC62nvY1LrkcGBQfgfGBzp9dR5Lpn/NcjF5bFMSWAQ== {"files":[{"bytes":18233,"name":"index.html","sha256":"d7ee743a07328c7829949691a08815788ad435f9c123cdd4b5807a0779573668"},{"bytes":7844,"name":"publication.md","sha256":"ad7417c7e23eb8fddce3fa29248030493f82c364a8f2b438100fc1750a0559b8"},{"bytes":7519,"name":"publication.txt","sha256":"9f45fc1aea31c748ba13d50f70d0521a99c9cce5eaf633537a7ef602e2e954ce"},{"bytes":2852,"name":"manifest.json","sha256":"11723bf4d35231cb73d0a3f841b9244e1b849a8a17e300baa4205720671a28a3"},{"bytes":89,"name":"manifest.sig","sha256":"ac5c3e7769b611acf2999beea1f08897f9a686b67276818bb5790122c880accf"},{"bytes":227,"name":"manifest.sig.txt","sha256":"47b81b8a7a65e9bf7152e5d4a32daa5de9f0e1157139bcbd24c0dcbdcbcc1901"}],"publication_id":"OT-2026-000089288"} Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089288
OpenTechnical

OT-2026-000089288

Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
9f45fc1aea31c748ba13d50f70d0521a99c9cce5eaf633537a7ef602e2e954ce

Abstract

A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089288, “Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089288.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089288" title: "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089288" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089288 Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089288 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089288 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089288 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089288", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1082 }, "figures": [], "files": [ { "bytes": 18233, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d7ee743a07328c7829949691a08815788ad435f9c123cdd4b5807a0779573668" }, { "bytes": 7844, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ad7417c7e23eb8fddce3fa29248030493f82c364a8f2b438100fc1750a0559b8" }, { "bytes": 7519, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9f45fc1aea31c748ba13d50f70d0521a99c9cce5eaf633537a7ef602e2e954ce" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089288/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089288", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7692-bf76-d495d475d039" } K8KJSZtMsU0glQ15m8jfUVXgqdx/U0Byv5YdQFnNXIjLcds+N0V42zYRrF0paSxtN+fTbIqekCeUnlcsoUfFCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: K8KJSZtMsU0glQ15m8jfUVXgqdx/U0Byv5YdQFnNXIjLcds+N0V42zYRrF0paSxtN+fTbIqekCeUnlcsoUfFCQ== {"files":[{"bytes":19048,"name":"index.html","sha256":"4f6e2080f3887aad27f6eaccdcaf660477e66f6dba9962b8f161413af4ecf764"},{"bytes":8545,"name":"publication.md","sha256":"307edeb8b84f752f27dfea740820e93ac06eaa362e41a54073ac49c2b7315b5e"},{"bytes":8214,"name":"publication.txt","sha256":"0ec9904e877be9af2a22d0c5039a802c4c5ae45297577992c6aaf2cdd156052f"},{"bytes":2864,"name":"manifest.json","sha256":"7b16112bc440e71ba4eb41a6c3198ba2bf77b005eeaa660fcd55882f4716d23d"},{"bytes":89,"name":"manifest.sig","sha256":"1695fcccb15d5c7e515877f827de615cb64630dcd6aefc762b1d2f65600540ad"},{"bytes":227,"name":"manifest.sig.txt","sha256":"904b27912ac5fa8c7af431a65ef37dcbb70926b56f617d2a836bacf6369cf301"}],"publication_id":"OT-2026-000089289"} Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089289
OpenTechnical

OT-2026-000089289

Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
0ec9904e877be9af2a22d0c5039a802c4c5ae45297577992c6aaf2cdd156052f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089289, “Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089289.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089289" title: "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089289" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089289 Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089289 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089289 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089289 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089289", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1188 }, "figures": [], "files": [ { "bytes": 19048, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4f6e2080f3887aad27f6eaccdcaf660477e66f6dba9962b8f161413af4ecf764" }, { "bytes": 8545, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "307edeb8b84f752f27dfea740820e93ac06eaa362e41a54073ac49c2b7315b5e" }, { "bytes": 8214, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0ec9904e877be9af2a22d0c5039a802c4c5ae45297577992c6aaf2cdd156052f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089289/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089289", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7965-af0f-25c8a82e0215" } +ViL41jkYwobiekCuBIHtyMj2KZiOxQu8RBKVatnynReI30bRsLIutt9tbvAXdYBlzXY24bRZ3UiIa4VuJxXCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: +ViL41jkYwobiekCuBIHtyMj2KZiOxQu8RBKVatnynReI30bRsLIutt9tbvAXdYBlzXY24bRZ3UiIa4VuJxXCQ== {"files":[{"bytes":18795,"name":"index.html","sha256":"4e466d90e0b72cc077604132cd534c5d7d25c7b5f63c1743ee02ac34cdcbff7b"},{"bytes":8335,"name":"publication.md","sha256":"7252d5fa2166abceb18e8867614f3c0802251f2704989b2b9a4486dcd734c2fd"},{"bytes":8004,"name":"publication.txt","sha256":"0c6b95652525bd9c83791ebaa9502d1c9208c33d66ee3afe44441880b37561eb"},{"bytes":2864,"name":"manifest.json","sha256":"75ed36e93ad261f5752c87ab6f48783552c75f96927943734fbae3123880a667"},{"bytes":89,"name":"manifest.sig","sha256":"63564f517be6274b772feb194a83d8eb587887d5ecb79bcee15a5414c717c663"},{"bytes":227,"name":"manifest.sig.txt","sha256":"6558f3c2e214562fe9c8aed1b2691f2ade1b91bc9b340b9b2633e9423209383e"}],"publication_id":"OT-2026-000089290"} Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089290
OpenTechnical

OT-2026-000089290

Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
0c6b95652525bd9c83791ebaa9502d1c9208c33d66ee3afe44441880b37561eb

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets.

[0006]Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining two manifold outlets are plugged and carry no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089290, “Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089290.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089290" title: "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089290" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Four suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] **Four zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089290 Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089290 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: four suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Four suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of four follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has six outlets. [0006] Four zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of four follows from the arrangement: one branch per zone. The distribution is divided into four zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured in the supply line. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the four zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the line between the vacuum pump and the distribution and reads the pressure of the whole circuit. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining two manifold outlets are plugged and carry no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the common supply line) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: six (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: four (sets how much of the face can be treated separately); placement of the pressure sensor: in the supply line (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089290 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089290 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, four suction cups, one vacuum pump, one manifold, four zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089290", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1153 }, "figures": [], "files": [ { "bytes": 18795, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4e466d90e0b72cc077604132cd534c5d7d25c7b5f63c1743ee02ac34cdcbff7b" }, { "bytes": 8335, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7252d5fa2166abceb18e8867614f3c0802251f2704989b2b9a4486dcd734c2fd" }, { "bytes": 8004, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0c6b95652525bd9c83791ebaa9502d1c9208c33d66ee3afe44441880b37561eb" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089290/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089290", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Four cup vacuum gripper, four zone face, six outlet manifold, pump fed, supply line pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-72b9-9bcb-b8a25ec71402" } 2uAFblPC6JFHEzXrWDQPXzd6UOwwJdNdNzDMZL3s+MfDpPwLIdC4os7mQJcizrFuYgWn6XAKAjGqZu18bxlXDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 2uAFblPC6JFHEzXrWDQPXzd6UOwwJdNdNzDMZL3s+MfDpPwLIdC4os7mQJcizrFuYgWn6XAKAjGqZu18bxlXDg== {"files":[{"bytes":18297,"name":"index.html","sha256":"68f8a983fe3b49aaa84e241046b183618752540e5b1e4249caf64c3e96d6c52d"},{"bytes":7917,"name":"publication.md","sha256":"66376bd4a424268c6a400c73d401c430c87abe49238663998e45deb5419acf1d"},{"bytes":7581,"name":"publication.txt","sha256":"059eb587762f1db40e2165c251dfef7a7e0a9254c2a8838347342ddafbcf393b"},{"bytes":2853,"name":"manifest.json","sha256":"09fc00504bf2d3dde7d2c856e1e04f02f59ac61f8985861fd243681a0bc42ef0"},{"bytes":89,"name":"manifest.sig","sha256":"cf247a97bd9c2092986073d8986da3d99010313c2394095998fc45feff9ca50a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"272626d30802af83628b72d0b8495c898903fc7987195015326ee06a321aade0"}],"publication_id":"OT-2026-000089291"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089291
OpenTechnical

OT-2026-000089291

Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
059eb587762f1db40e2165c251dfef7a7e0a9254c2a8838347342ddafbcf393b

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089291, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089291.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089291" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089291" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089291 Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089291 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089291 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089291 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089291", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18297, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "68f8a983fe3b49aaa84e241046b183618752540e5b1e4249caf64c3e96d6c52d" }, { "bytes": 7917, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "66376bd4a424268c6a400c73d401c430c87abe49238663998e45deb5419acf1d" }, { "bytes": 7581, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "059eb587762f1db40e2165c251dfef7a7e0a9254c2a8838347342ddafbcf393b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089291/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089291", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-77a0-b820-6c0067d37b3c" } nFKPjEQBIISs8iTCCbllCZ91DpZ1117Q8qn0CbrfutYdIB/RxLN3g9f6dGgKdt2zNhOGG5hEOgJtNALI6wiGDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: nFKPjEQBIISs8iTCCbllCZ91DpZ1117Q8qn0CbrfutYdIB/RxLN3g9f6dGgKdt2zNhOGG5hEOgJtNALI6wiGDg== {"files":[{"bytes":19112,"name":"index.html","sha256":"f5ca24800415c1c69a7f7033588f016745adaaa297d214768eef27b3d501d5ca"},{"bytes":8618,"name":"publication.md","sha256":"49368c1bfd35d087695db9315f882ac704cf81503278954aa2ef08b44c6e943c"},{"bytes":8276,"name":"publication.txt","sha256":"38373a5a3a475b0aef0e4a44e6e81c31997f4a35c7c7eac5fef433a0bd28e06f"},{"bytes":2865,"name":"manifest.json","sha256":"9ca2fecdcaef039d0b931a6748e8a54ebc47adf337c77c6d9999ef7f55b055a6"},{"bytes":89,"name":"manifest.sig","sha256":"7ad7a4e6a1e4d50239cdea267f72453d2a8c78e0ce9040bcf0875d4e03a73316"},{"bytes":227,"name":"manifest.sig.txt","sha256":"6a207231f7aba95d3f55f95b766e293bb27c2df9fe81dd5c3c798c7bdfcbc001"}],"publication_id":"OT-2026-000089292"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089292
OpenTechnical

OT-2026-000089292

Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
38373a5a3a475b0aef0e4a44e6e81c31997f4a35c7c7eac5fef433a0bd28e06f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089292, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089292.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089292" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089292" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089292 Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089292 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089292 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089292 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089292", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19112, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f5ca24800415c1c69a7f7033588f016745adaaa297d214768eef27b3d501d5ca" }, { "bytes": 8618, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "49368c1bfd35d087695db9315f882ac704cf81503278954aa2ef08b44c6e943c" }, { "bytes": 8276, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "38373a5a3a475b0aef0e4a44e6e81c31997f4a35c7c7eac5fef433a0bd28e06f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089292/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089292", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7856-b762-866877676c2f" } EU5aUB1iG2Xr0ZGjirvCyvcWUf0MrEcEL6n8yiwOvad9qxL7ul+IlBizzICU96W6RjCR9W/bpGZGKAkjQlZNAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: EU5aUB1iG2Xr0ZGjirvCyvcWUf0MrEcEL6n8yiwOvad9qxL7ul+IlBizzICU96W6RjCR9W/bpGZGKAkjQlZNAQ== {"files":[{"bytes":18859,"name":"index.html","sha256":"3f467d12d6741b8f88665506401014b4a0517ce7bfb05be3323485545d2818ad"},{"bytes":8408,"name":"publication.md","sha256":"f337030dc332a3023231de1aaa8d151d2977ed85253cc95be69c4d0e6e54b2f7"},{"bytes":8066,"name":"publication.txt","sha256":"5d2cd1e862ad55df892682ec2c426ad607499895c5a48d6e9eb6b4a67b16f3da"},{"bytes":2865,"name":"manifest.json","sha256":"57de47fd01fa7a637ccee313bdc37e34c39919fb11e661d0dc1aeda52a5aae63"},{"bytes":89,"name":"manifest.sig","sha256":"5aec9046b75697e6bf80d8ce7b603cec42752f02ac0b4336d92e199a53825a75"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e074d9e1b098cafb2419db4e9dc60cdb69ba0897c56ee932f6ee347c1d278749"}],"publication_id":"OT-2026-000089293"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089293
OpenTechnical

OT-2026-000089293

Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
5d2cd1e862ad55df892682ec2c426ad607499895c5a48d6e9eb6b4a67b16f3da

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089293, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089293.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089293" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089293" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089293 Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089293 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089293 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089293 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089293", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18859, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3f467d12d6741b8f88665506401014b4a0517ce7bfb05be3323485545d2818ad" }, { "bytes": 8408, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f337030dc332a3023231de1aaa8d151d2977ed85253cc95be69c4d0e6e54b2f7" }, { "bytes": 8066, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5d2cd1e862ad55df892682ec2c426ad607499895c5a48d6e9eb6b4a67b16f3da" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089293/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089293", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7813-a856-dbd6c473c46e" } hoj5YI0pqHGnPLI2qBI96siua/E/bzAUcH+ZPHNCdG83bVUYVisKRREJ7gdBiOKVebdwTZKaMfnbju4Mu+PQDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: hoj5YI0pqHGnPLI2qBI96siua/E/bzAUcH+ZPHNCdG83bVUYVisKRREJ7gdBiOKVebdwTZKaMfnbju4Mu+PQDA== {"files":[{"bytes":18298,"name":"index.html","sha256":"c5fd4b29dcb19ded1fee5160ec2074ee13d971d8d970719a2e04f219f7e67bd0"},{"bytes":7918,"name":"publication.md","sha256":"f7449a232cd859b9c93f2fc12f9b046c08fa14a47f1026cbd7eb1b35c017151d"},{"bytes":7582,"name":"publication.txt","sha256":"dfd66ad1e5fd6f2f042059ecac367a5680bf63f6f371f1a889a4e71dd6293ae2"},{"bytes":2853,"name":"manifest.json","sha256":"3650e003b61b8405232b5e6bd623332e53948e98a3fd43b2c68379e3a56f9148"},{"bytes":89,"name":"manifest.sig","sha256":"b2819440c971d88057f485d0458b34ba3f3fcc27394b65a8b7e827438cb75587"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ff6f01a5c2533691b2745e2de896734bc2154c48ee0cd53b5fdf212ab25b0a36"}],"publication_id":"OT-2026-000089294"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089294
OpenTechnical

OT-2026-000089294

Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
dfd66ad1e5fd6f2f042059ecac367a5680bf63f6f371f1a889a4e71dd6293ae2

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089294, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089294.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089294" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089294" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089294 Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089294 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089294 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089294 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089294", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18298, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c5fd4b29dcb19ded1fee5160ec2074ee13d971d8d970719a2e04f219f7e67bd0" }, { "bytes": 7918, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f7449a232cd859b9c93f2fc12f9b046c08fa14a47f1026cbd7eb1b35c017151d" }, { "bytes": 7582, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "dfd66ad1e5fd6f2f042059ecac367a5680bf63f6f371f1a889a4e71dd6293ae2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089294/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089294", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7eca-9e31-1197c179c0ea" } bi74LDsUUH9D2/tnesIq4D1qYo5SWDfSej4VZ4IgtCgPoc7MzFBtQYMWx60Eua8iYIZytMcbod9knHrZECZ8Cg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: bi74LDsUUH9D2/tnesIq4D1qYo5SWDfSej4VZ4IgtCgPoc7MzFBtQYMWx60Eua8iYIZytMcbod9knHrZECZ8Cg== {"files":[{"bytes":19113,"name":"index.html","sha256":"a9b7d40bf0f39fb833bcf0e34663215ad94672e775710980ed83c1035935d38f"},{"bytes":8619,"name":"publication.md","sha256":"9aa095c01973b845b9a7e952a08b1444eea1d54c5ab0488941ae5ff502743bc6"},{"bytes":8277,"name":"publication.txt","sha256":"b2b9cda846ba5a3b0f06edaa2d17f37aeee16955fb3fd23aa54d6ab7bfe57270"},{"bytes":2865,"name":"manifest.json","sha256":"6370a17921f6ddc77ba65ff3f18b4871e288244f2882e53ac773ae5883edcbe1"},{"bytes":89,"name":"manifest.sig","sha256":"e2cb5c1d37a77ef3bdd05f8482d767d51248f1555bdaecb1f5297f1f1b13dfe9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1c000f80e814ca3b253c35b071c599c335fb4aca5a518d13672aa559a39ebce2"}],"publication_id":"OT-2026-000089295"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089295
OpenTechnical

OT-2026-000089295

Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
b2b9cda846ba5a3b0f06edaa2d17f37aeee16955fb3fd23aa54d6ab7bfe57270

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089295, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089295.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089295" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089295" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089295 Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089295 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089295 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089295 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089295", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19113, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a9b7d40bf0f39fb833bcf0e34663215ad94672e775710980ed83c1035935d38f" }, { "bytes": 8619, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9aa095c01973b845b9a7e952a08b1444eea1d54c5ab0488941ae5ff502743bc6" }, { "bytes": 8277, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b2b9cda846ba5a3b0f06edaa2d17f37aeee16955fb3fd23aa54d6ab7bfe57270" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089295/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089295", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7836-9051-e48087338fc5" } 2TMRTdzUP3LIQuv+8pdPV9BTKMdZ3Zqxj7+nWGGVJmalZuxGsXdemgVk6tmdcHU9jKZl8HPVmyJVgMOm3DehBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 2TMRTdzUP3LIQuv+8pdPV9BTKMdZ3Zqxj7+nWGGVJmalZuxGsXdemgVk6tmdcHU9jKZl8HPVmyJVgMOm3DehBQ== {"files":[{"bytes":18860,"name":"index.html","sha256":"0a192a58d63bb6ff9f104e437553d1c2be257da86ada09f0c846f1fd09e1eefe"},{"bytes":8409,"name":"publication.md","sha256":"18c6ec9c49bb90ccb5565bbc677a824ab6cadaddd84d4d6bc3fa8fe8ce1c3e63"},{"bytes":8067,"name":"publication.txt","sha256":"674bf1ca188449c46550fa4248f8d41b55c35cf55a6694be985f98932a3ef6c6"},{"bytes":2865,"name":"manifest.json","sha256":"ee6c18dafa1c340521984c65f202019f10ffc61f3f8dc216526e5786a1928708"},{"bytes":89,"name":"manifest.sig","sha256":"3e9d85cbab9888a38965a4a84480f4b3232a206e1155f057683e489eec0afe7c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f0d448fa0e4d93d193799ab18a8d5a23df4c1f3394284c2044a7088142c294fa"}],"publication_id":"OT-2026-000089296"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089296
OpenTechnical

OT-2026-000089296

Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
674bf1ca188449c46550fa4248f8d41b55c35cf55a6694be985f98932a3ef6c6

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089296, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089296.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089296" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089296" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089296 Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089296 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089296 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089296 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089296", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18860, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0a192a58d63bb6ff9f104e437553d1c2be257da86ada09f0c846f1fd09e1eefe" }, { "bytes": 8409, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "18c6ec9c49bb90ccb5565bbc677a824ab6cadaddd84d4d6bc3fa8fe8ce1c3e63" }, { "bytes": 8067, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "674bf1ca188449c46550fa4248f8d41b55c35cf55a6694be985f98932a3ef6c6" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089296/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089296", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7b24-94bd-1e2e39417221" } 96ENRGrT9N008rNSf4BzRTpNryDBYm6oBGCIXm8rM8ogHqaPpnRIVyvjWf7Rf/EC5uHU7BrQkZSgAhnlOP3SDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 96ENRGrT9N008rNSf4BzRTpNryDBYm6oBGCIXm8rM8ogHqaPpnRIVyvjWf7Rf/EC5uHU7BrQkZSgAhnlOP3SDw== {"files":[{"bytes":18302,"name":"index.html","sha256":"4b0cd5bcdb696fe1d7ebd71c9598b7abcb7c38619d86f965795fe3ec9b65dc55"},{"bytes":7922,"name":"publication.md","sha256":"aae004e4206a6d4746c717a29f27f4a34cfac60368f7886b8dd19d7591beb32f"},{"bytes":7586,"name":"publication.txt","sha256":"6b54e2543900d0689518d2d750c5beb1c5cb5e9401e49b6c7e8409ee248adb04"},{"bytes":2853,"name":"manifest.json","sha256":"b72c07155997fc55cb8f776e09c05eb1a2085ead6103d10a70d5e57b67a4d616"},{"bytes":89,"name":"manifest.sig","sha256":"45da2da86eda839df371083d8d8138c6948d62395db56538d4f387d10729ac14"},{"bytes":227,"name":"manifest.sig.txt","sha256":"05a8ffb91789c990b2c33e9e0a8d46452d617691cbf5afef1109ec24e2da917e"}],"publication_id":"OT-2026-000089297"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089297
OpenTechnical

OT-2026-000089297

Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
6b54e2543900d0689518d2d750c5beb1c5cb5e9401e49b6c7e8409ee248adb04

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089297, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089297.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089297" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089297" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089297 Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089297 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089297 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089297 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089297", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18302, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4b0cd5bcdb696fe1d7ebd71c9598b7abcb7c38619d86f965795fe3ec9b65dc55" }, { "bytes": 7922, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "aae004e4206a6d4746c717a29f27f4a34cfac60368f7886b8dd19d7591beb32f" }, { "bytes": 7586, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "6b54e2543900d0689518d2d750c5beb1c5cb5e9401e49b6c7e8409ee248adb04" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089297/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089297", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7336-b838-d424422533cc" } zSfbeuKwAkrdzGblWsbGJVBjLFAe7faFjWm6o8vaRG2XUyAw7k00rsY/W+hPRUz6CylueBOZ6iJh3CsYc59qAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: zSfbeuKwAkrdzGblWsbGJVBjLFAe7faFjWm6o8vaRG2XUyAw7k00rsY/W+hPRUz6CylueBOZ6iJh3CsYc59qAg== {"files":[{"bytes":19117,"name":"index.html","sha256":"96d14d2e90777d029041e19d2278351c1654b703a58ed4165a3b94646c21f7b0"},{"bytes":8623,"name":"publication.md","sha256":"cc534e9bd5306503aaf63ce7046590e3e479216b9695dfc963e017ad92cc8bb4"},{"bytes":8281,"name":"publication.txt","sha256":"a753f5df91aaab79a2d178b7a3dee7c50dc9995ef1aeeabbb9396caa146e7d99"},{"bytes":2865,"name":"manifest.json","sha256":"8d125e6842d0b9e3f4d08ce9ba6e8da4302f593a3bc9e63f35d06cd19d6e1089"},{"bytes":89,"name":"manifest.sig","sha256":"2e56e393c3fd59f513c5c72c071c9225b4b727e5a94362a946446b939c28895a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e1ef5e605551044e7321130e7b32eee43e851bd68d6782702aae220968b43db2"}],"publication_id":"OT-2026-000089298"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089298
OpenTechnical

OT-2026-000089298

Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a753f5df91aaab79a2d178b7a3dee7c50dc9995ef1aeeabbb9396caa146e7d99

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089298, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089298.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089298" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089298" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089298 Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089298 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089298 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089298 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089298", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19117, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "96d14d2e90777d029041e19d2278351c1654b703a58ed4165a3b94646c21f7b0" }, { "bytes": 8623, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cc534e9bd5306503aaf63ce7046590e3e479216b9695dfc963e017ad92cc8bb4" }, { "bytes": 8281, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a753f5df91aaab79a2d178b7a3dee7c50dc9995ef1aeeabbb9396caa146e7d99" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089298/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089298", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7272-b897-642d3b4f6d7d" } 4UYghCkag9NISvAGILuRF0d3AZgYoiqfQk6Nv+K7f41eruNluteZoxzVOAgMgPxOJtjPAk+H309wBZHtP102Bw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 4UYghCkag9NISvAGILuRF0d3AZgYoiqfQk6Nv+K7f41eruNluteZoxzVOAgMgPxOJtjPAk+H309wBZHtP102Bw== {"files":[{"bytes":18864,"name":"index.html","sha256":"bbd77603fe3c7782b11b14ed824e8e3157b99ccecec6c708616b6aa2b8915c0f"},{"bytes":8413,"name":"publication.md","sha256":"7b72bacb5cff1af8f1afd7ff45bd9dc6f00e2bedfc501c916f72ada42b39de93"},{"bytes":8071,"name":"publication.txt","sha256":"259cb4d4269743540fb477e45ce8e9ee28dc799f604ac0237bbfac1b7eeb7bec"},{"bytes":2865,"name":"manifest.json","sha256":"5f427c00c453f76682edf5d6e6ca447096299484c75bbf9938030980616f40f6"},{"bytes":89,"name":"manifest.sig","sha256":"68580c966d101d6231d25b6b6efcc58c20eb4011024d9072dca650bd69d8254e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"41800acb0bf60d3805fa377d4f92ec89e51e64833945f92bbbf7e9a82100e4e4"}],"publication_id":"OT-2026-000089299"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089299
OpenTechnical

OT-2026-000089299

Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
259cb4d4269743540fb477e45ce8e9ee28dc799f604ac0237bbfac1b7eeb7bec

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089299, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089299.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089299" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089299" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089299 Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089299 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089299 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089299 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089299", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18864, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bbd77603fe3c7782b11b14ed824e8e3157b99ccecec6c708616b6aa2b8915c0f" }, { "bytes": 8413, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7b72bacb5cff1af8f1afd7ff45bd9dc6f00e2bedfc501c916f72ada42b39de93" }, { "bytes": 8071, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "259cb4d4269743540fb477e45ce8e9ee28dc799f604ac0237bbfac1b7eeb7bec" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089299/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089299", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-71f7-95be-6490345c1a01" } W9V1XlU0ZUU0pKJ9Wqu0dWH7F1w07mSfB5kIHiFVVTgdE2e4kiDAgBKaeuiwIIId0SfbKb59BEsRCa8O/kumBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: W9V1XlU0ZUU0pKJ9Wqu0dWH7F1w07mSfB5kIHiFVVTgdE2e4kiDAgBKaeuiwIIId0SfbKb59BEsRCa8O/kumBQ== {"files":[{"bytes":19189,"name":"index.html","sha256":"7d747b6c492afa32ed0ed4b086dc415a64920a6aacbfda5ead587c844df637c1"},{"bytes":8730,"name":"publication.md","sha256":"d71174cdae39605c885ab98ba1b1944dceba9622d220c223f1e4887295fcd8ca"},{"bytes":8386,"name":"publication.txt","sha256":"38a530e354c36ab09a1d11390448cae7f67a91d56fef33b65abdc7c9833ac376"},{"bytes":2888,"name":"manifest.json","sha256":"871db0fe919fb0ac4233e89dde3d0e830aeeb28925d1ec47e1000a5e29edf3a4"},{"bytes":89,"name":"manifest.sig","sha256":"4ab996ca3ec54d45f5e06d21a6ab991cbd8b52669c95b1be270433216e348eaa"},{"bytes":227,"name":"manifest.sig.txt","sha256":"72f83af548be82ae30d5851410e53780062d43c0f5653e01895d9c0a9553c1e5"}],"publication_id":"OT-2026-000089300"} Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089300
OpenTechnical

OT-2026-000089300

Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
38a530e354c36ab09a1d11390448cae7f67a91d56fef33b65abdc7c9833ac376

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0019]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089300, “Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089300.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089300" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089300" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089300 Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089300 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089300 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089300 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089300", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1220 }, "figures": [], "files": [ { "bytes": 19189, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7d747b6c492afa32ed0ed4b086dc415a64920a6aacbfda5ead587c844df637c1" }, { "bytes": 8730, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d71174cdae39605c885ab98ba1b1944dceba9622d220c223f1e4887295fcd8ca" }, { "bytes": 8386, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "38a530e354c36ab09a1d11390448cae7f67a91d56fef33b65abdc7c9833ac376" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089300/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089300", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7196-8b0e-1c6ba465df20" } K41tiR1Yz4c2FDRwIYb1qs7kk/lVFzcIonPvGkpDheX6ZKwsqT1tL9oxC9NKPBReF14VHbX3d1wB9ipKMfFKDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: K41tiR1Yz4c2FDRwIYb1qs7kk/lVFzcIonPvGkpDheX6ZKwsqT1tL9oxC9NKPBReF14VHbX3d1wB9ipKMfFKDA== {"files":[{"bytes":18936,"name":"index.html","sha256":"8e6ddc81fe854b913b52ff551891dfaaa581915287ce10213e8d6f75ef132338"},{"bytes":8520,"name":"publication.md","sha256":"934beabb9fd569b11bff2c343424834ea12e67724cb0655c1d12ab27574c43cd"},{"bytes":8176,"name":"publication.txt","sha256":"3042e92101b4458672c0eda29b8a40627d0722d73247805a9e89d8c492880c59"},{"bytes":2888,"name":"manifest.json","sha256":"0405a0322e662a84e24713de4d5757baa61776b6cb68ebaba52de6e2b976dc8b"},{"bytes":89,"name":"manifest.sig","sha256":"07dc71f118f8026c3ca5ae966588fe6cd48765cc1fea0646380ed8f42ab28436"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d16523d5bb34c41febfc6ae7909119f962f99133cf267b914ffed1c86b1c1ae5"}],"publication_id":"OT-2026-000089301"} Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089301
OpenTechnical

OT-2026-000089301

Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
3042e92101b4458672c0eda29b8a40627d0722d73247805a9e89d8c492880c59

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089301, “Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089301.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089301" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089301" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089301 Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089301 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089301 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089301 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089301", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1185 }, "figures": [], "files": [ { "bytes": 18936, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8e6ddc81fe854b913b52ff551891dfaaa581915287ce10213e8d6f75ef132338" }, { "bytes": 8520, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "934beabb9fd569b11bff2c343424834ea12e67724cb0655c1d12ab27574c43cd" }, { "bytes": 8176, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3042e92101b4458672c0eda29b8a40627d0722d73247805a9e89d8c492880c59" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089301/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089301", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-773e-b88f-163929b34c1a" } rISrcEvQQfkX3qNsrDBpL6y94QSYBZOcCunPFwqRaMimz3deUMlGlEAailS+Ty/7396Z09Kfz9wq92Nps6bNAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: rISrcEvQQfkX3qNsrDBpL6y94QSYBZOcCunPFwqRaMimz3deUMlGlEAailS+Ty/7396Z09Kfz9wq92Nps6bNAA== {"files":[{"bytes":18329,"name":"index.html","sha256":"1a4935c4211553b712f3ac49332b8d570b183d3384bd00c5be6222178ceef0c4"},{"bytes":7988,"name":"publication.md","sha256":"e072a6b645b926cfe05b815c5ec8e6ce566de6727918e39669e9682a820b34a1"},{"bytes":7643,"name":"publication.txt","sha256":"5972ca13a7632873fe90df45f13192999e63d5ca461c56d4f098459ac8a33198"},{"bytes":2883,"name":"manifest.json","sha256":"568e65e66c1f70dd02923bfee3f734e2c99f9ab7fbe69e28c7b2bb9bc4ea34ae"},{"bytes":89,"name":"manifest.sig","sha256":"fe0e3ffed52816f8f5c3be66cdf15b6fac1c157cf0cc21c755ca6d3a33220e90"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e4e1751cd946663d62931a3b31fe97cf618ac6224c5ffbc1694a833a661fb023"}],"publication_id":"OT-2026-000089302"} Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089302
OpenTechnical

OT-2026-000089302

Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
5972ca13a7632873fe90df45f13192999e63d5ca461c56d4f098459ac8a33198

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089302, “Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089302.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089302" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089302" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089302 Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089302 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089302 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089302 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089302", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1099 }, "figures": [], "files": [ { "bytes": 18329, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1a4935c4211553b712f3ac49332b8d570b183d3384bd00c5be6222178ceef0c4" }, { "bytes": 7988, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e072a6b645b926cfe05b815c5ec8e6ce566de6727918e39669e9682a820b34a1" }, { "bytes": 7643, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5972ca13a7632873fe90df45f13192999e63d5ca461c56d4f098459ac8a33198" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089302/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089302", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-728c-9cc8-7816be64c50e" } wqyX3gLnSHukO3w9fw0mSEbeh5tbUrP2wV+hs/cIoETqljjuVKlzcGZwQVLCbnKUNcAeNwjW+jsv4xc8Rj7KCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: wqyX3gLnSHukO3w9fw0mSEbeh5tbUrP2wV+hs/cIoETqljjuVKlzcGZwQVLCbnKUNcAeNwjW+jsv4xc8Rj7KCg== {"files":[{"bytes":19135,"name":"index.html","sha256":"30dc02dd9ec0597754fce56da6c3bc799b2a2aec5e7145b7c026eab40b2717af"},{"bytes":8676,"name":"publication.md","sha256":"8cd3f94a38a0f0914e8d02974a98887fd3306c2b9efbccd1f3dbb30e697017e5"},{"bytes":8332,"name":"publication.txt","sha256":"189b517bd45cea427027e16095a5e243c830ca6b8277724db592f27431cb0c5d"},{"bytes":2888,"name":"manifest.json","sha256":"9916d8e753f6d92b0512659399691334988ad2831905b248e581e13dd77c4cc5"},{"bytes":89,"name":"manifest.sig","sha256":"1f8d161b5271a6985561bec2e52b67731d7865af679f9ec6fa77d3de2582cac6"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3e67cb24e2bb390de2fb4d94dc4d5bd39495644547aff327f5e8fa6f17ffa0d5"}],"publication_id":"OT-2026-000089303"} Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089303
OpenTechnical

OT-2026-000089303

Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
189b517bd45cea427027e16095a5e243c830ca6b8277724db592f27431cb0c5d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0019]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089303, “Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089303.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089303" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089303" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089303 Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089303 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089303 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089303 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089303", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1205 }, "figures": [], "files": [ { "bytes": 19135, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "30dc02dd9ec0597754fce56da6c3bc799b2a2aec5e7145b7c026eab40b2717af" }, { "bytes": 8676, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8cd3f94a38a0f0914e8d02974a98887fd3306c2b9efbccd1f3dbb30e697017e5" }, { "bytes": 8332, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "189b517bd45cea427027e16095a5e243c830ca6b8277724db592f27431cb0c5d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089303/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089303", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-774d-9fe9-91999d42dc41" } VoHSccJCCNcfDqFS96EN4aCFxRC+di+MODKo0j2E5Ngwf7YB5AgDHRCcGfv+UlEv4NhfOlAB1a3MKmMdswWKCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: VoHSccJCCNcfDqFS96EN4aCFxRC+di+MODKo0j2E5Ngwf7YB5AgDHRCcGfv+UlEv4NhfOlAB1a3MKmMdswWKCw== {"files":[{"bytes":18882,"name":"index.html","sha256":"967e22939a1ff6cd60016698f5a0712a519d9df2286720ae734ea8f0fa5a74f7"},{"bytes":8466,"name":"publication.md","sha256":"e7bd70247500422fc12fd6ca971185f5885a70d4f4606e82cbd947f8388ea505"},{"bytes":8122,"name":"publication.txt","sha256":"120a732ad513f5d6acbfaf47ff0fd86e2b1df4aee7cf63d515f08588c266d944"},{"bytes":2888,"name":"manifest.json","sha256":"2caa6c28182a8c0c042849d647d643813444002bb7c0f726485141195f8146c3"},{"bytes":89,"name":"manifest.sig","sha256":"0a3299b6ae58e52ffdbe1336cd9ecfdd34b2f7141078bd7ebbd9c0e7e87a850a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"45ae6c27b9c48dc6164fb641a4fa2426bfcaaf771c10553b51ea249b33ef8dbc"}],"publication_id":"OT-2026-000089304"} Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089304
OpenTechnical

OT-2026-000089304

Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
120a732ad513f5d6acbfaf47ff0fd86e2b1df4aee7cf63d515f08588c266d944

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089304, “Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089304.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089304" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089304" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089304 Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089304 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089304 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089304 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089304", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1170 }, "figures": [], "files": [ { "bytes": 18882, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "967e22939a1ff6cd60016698f5a0712a519d9df2286720ae734ea8f0fa5a74f7" }, { "bytes": 8466, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e7bd70247500422fc12fd6ca971185f5885a70d4f4606e82cbd947f8388ea505" }, { "bytes": 8122, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "120a732ad513f5d6acbfaf47ff0fd86e2b1df4aee7cf63d515f08588c266d944" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089304/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089304", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-78bc-beb1-783fd6b64682" } Sv/2r+hH+WialPAqt99KRmqoTwP3lZMSW1jbAyD9iOqqgyrSXeR98DWOxpZl/NPpXrcuyCSokhetRXVfGPEtDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Sv/2r+hH+WialPAqt99KRmqoTwP3lZMSW1jbAyD9iOqqgyrSXeR98DWOxpZl/NPpXrcuyCSokhetRXVfGPEtDw== {"files":[{"bytes":18083,"name":"index.html","sha256":"dde39002235310e0091ae44b7dc4f09f0da5f44fe1bdcfc73d90208a7659af2c"},{"bytes":7790,"name":"publication.md","sha256":"93a5842bdb7ca0f678054602cebe27a1a18ccec4389f733b21dbc0fbf8d288fa"},{"bytes":7443,"name":"publication.txt","sha256":"b961a159c0348cd55b6289c27799f16427f2478df96ffef1370142a891e909bd"},{"bytes":2896,"name":"manifest.json","sha256":"5b6f08657e230df3bebaa050ab9f8d8e7d5379328f7e9611487b193185b9af82"},{"bytes":89,"name":"manifest.sig","sha256":"5ce3addc5169e397fe9efd378d4e7f7592f83918730340cd57b7a1ebc45fa212"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9dc81d3be63fe4f363bd5e99183233368f20ee41ef90bb9a85eac2cbf09cc24b"}],"publication_id":"OT-2026-000089305"} Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089305
OpenTechnical

OT-2026-000089305

Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
b961a159c0348cd55b6289c27799f16427f2478df96ffef1370142a891e909bd

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0029]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0030]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089305, “Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089305.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089305" title: "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089305" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0030] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089305 Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089305 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0030] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089305 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089305 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089305", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 30, "words": 1062 }, "figures": [], "files": [ { "bytes": 18083, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "dde39002235310e0091ae44b7dc4f09f0da5f44fe1bdcfc73d90208a7659af2c" }, { "bytes": 7790, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "93a5842bdb7ca0f678054602cebe27a1a18ccec4389f733b21dbc0fbf8d288fa" }, { "bytes": 7443, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b961a159c0348cd55b6289c27799f16427f2478df96ffef1370142a891e909bd" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089305/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089305", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-765a-91c3-14192eb80960" } FF04HvIJ7bmF7lMeu1rpuYX/YsvbfOxhpYbnWm4l+Fxdp5hps5qmsFiuxEpTgFyfj9WteDtYzgEX9jnWIdXuCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: FF04HvIJ7bmF7lMeu1rpuYX/YsvbfOxhpYbnWm4l+Fxdp5hps5qmsFiuxEpTgFyfj9WteDtYzgEX9jnWIdXuCQ== {"files":[{"bytes":18889,"name":"index.html","sha256":"7d04bf55a63d45b3a06ed2990770cf311ffcc1f3042729e5bc7d6055110acb2e"},{"bytes":8478,"name":"publication.md","sha256":"3171199b10fe6fee8c8f73e365b969319c159413c1872a75ec76aa8f9390dcdc"},{"bytes":8132,"name":"publication.txt","sha256":"796f8281afb34225a2c7403544ed72ead1fe7b2e584298f492fb8a6433eaffc7"},{"bytes":2901,"name":"manifest.json","sha256":"d3bced75a031c41e77f9c4e32a92d499496f199891d0aa35705c7164decc1d57"},{"bytes":89,"name":"manifest.sig","sha256":"56b153388a59fa39be746721ea6053e3216008b740e3ba4859e629f1ff2e322d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"be25416b04f8a301a3809a49a0efaab6fa6c24b2ab634e85406f5cfdf164d062"}],"publication_id":"OT-2026-000089306"} Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089306
OpenTechnical

OT-2026-000089306

Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
796f8281afb34225a2c7403544ed72ead1fe7b2e584298f492fb8a6433eaffc7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0019]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089306, “Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089306.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089306" title: "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089306" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089306 Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089306 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089306 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089306 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089306", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1168 }, "figures": [], "files": [ { "bytes": 18889, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7d04bf55a63d45b3a06ed2990770cf311ffcc1f3042729e5bc7d6055110acb2e" }, { "bytes": 8478, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3171199b10fe6fee8c8f73e365b969319c159413c1872a75ec76aa8f9390dcdc" }, { "bytes": 8132, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "796f8281afb34225a2c7403544ed72ead1fe7b2e584298f492fb8a6433eaffc7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089306/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089306", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7f18-a250-aa230e346199" } ArzhwEKEA4IW8ULo+MNRcd5EY+SyaKtf9tQzU5onlEWvCVlgFbB8xGXf4xS6nXPSKlmS5LbgCpm51z28/qjfCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ArzhwEKEA4IW8ULo+MNRcd5EY+SyaKtf9tQzU5onlEWvCVlgFbB8xGXf4xS6nXPSKlmS5LbgCpm51z28/qjfCg== {"files":[{"bytes":18636,"name":"index.html","sha256":"4f1752a7a5621c53afd51615fe5438c57da838c811a8d5cba401322b2bcea1b1"},{"bytes":8268,"name":"publication.md","sha256":"f9eab14ed9dcb552293b697c07b71b3d884f2042d004ee620c82f8c3d777e553"},{"bytes":7922,"name":"publication.txt","sha256":"5d12014ba067234db9296a967fba27072b4c50004838cf27e8adf8231a5e7380"},{"bytes":2901,"name":"manifest.json","sha256":"00eec6e30806afa5fa799a60849c5f393ef6c1403fb234a7a7f2f1c18d9a9d04"},{"bytes":89,"name":"manifest.sig","sha256":"70995753b79c97fa2a06d5f3fbf3d3f067dbfc89edd07d65cc5fa750609f22ef"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1fe03c5241f2d777ef5fb69452f495cb2c0258a358f61c3cf5403f061b3d8288"}],"publication_id":"OT-2026-000089307"} Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089307
OpenTechnical

OT-2026-000089307

Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
5d12014ba067234db9296a967fba27072b4c50004838cf27e8adf8231a5e7380

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0029]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089307, “Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089307.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089307" title: "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089307" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089307 Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089307 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089307 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089307 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089307", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1133 }, "figures": [], "files": [ { "bytes": 18636, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4f1752a7a5621c53afd51615fe5438c57da838c811a8d5cba401322b2bcea1b1" }, { "bytes": 8268, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f9eab14ed9dcb552293b697c07b71b3d884f2042d004ee620c82f8c3d777e553" }, { "bytes": 7922, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5d12014ba067234db9296a967fba27072b4c50004838cf27e8adf8231a5e7380" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089307/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089307", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7239-bfcc-c6009a22adf0" } e4NXWNy097SjUpBubA4XzRE+xD4LIfymMccX3p5EpUiLpYPobDhPcV0dICXGPrAD2YFtit+NuN9M6D2Upv+iDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: e4NXWNy097SjUpBubA4XzRE+xD4LIfymMccX3p5EpUiLpYPobDhPcV0dICXGPrAD2YFtit+NuN9M6D2Upv+iDw== {"files":[{"bytes":18083,"name":"index.html","sha256":"8c73b4e0047f920bc5fea90a1b5352e12f57b4efa0d0df100c41be46cb330254"},{"bytes":7790,"name":"publication.md","sha256":"19e6ea7cda19430600cd6e78d855f8f6d84e2d1bdd22f6116198fa346d66448d"},{"bytes":7443,"name":"publication.txt","sha256":"6f79dc0cd23d6fb48df9d14a59a4143b8127e507baf992656ef43418e174106f"},{"bytes":2896,"name":"manifest.json","sha256":"9f14cd2d6edd363acc9e04a2df98366a05d155ddebfed11c27b6765c2bdd987d"},{"bytes":89,"name":"manifest.sig","sha256":"4fc2b8756bbd40e517f85fa149eacaaf1fe7c2c9cdbb85204ad6c3879a9a3938"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ada5b4c22cb0ed07fb7781501df4d12f66bbe90773ac40bc6a3ed2059b8cc43c"}],"publication_id":"OT-2026-000089308"} Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089308
OpenTechnical

OT-2026-000089308

Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
6f79dc0cd23d6fb48df9d14a59a4143b8127e507baf992656ef43418e174106f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0029]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0030]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089308, “Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089308.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089308" title: "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089308" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0030] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089308 Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089308 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0030] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089308 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089308 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089308", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 30, "words": 1062 }, "figures": [], "files": [ { "bytes": 18083, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8c73b4e0047f920bc5fea90a1b5352e12f57b4efa0d0df100c41be46cb330254" }, { "bytes": 7790, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "19e6ea7cda19430600cd6e78d855f8f6d84e2d1bdd22f6116198fa346d66448d" }, { "bytes": 7443, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "6f79dc0cd23d6fb48df9d14a59a4143b8127e507baf992656ef43418e174106f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089308/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089308", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7497-a34f-f2cd525845a9" } G4MPsU1fVyKC3yVD7tgUM3/UalKZgL/Er5famQCKd1UFPpG0DzooXPmDi0HROJC8JlqkF/MFwDkqZg+doX2DBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: G4MPsU1fVyKC3yVD7tgUM3/UalKZgL/Er5famQCKd1UFPpG0DzooXPmDi0HROJC8JlqkF/MFwDkqZg+doX2DBQ== {"files":[{"bytes":18889,"name":"index.html","sha256":"b13548681e53d72f0237209f443bc4e721bcf28519a21971a8d2f9cbbdea8608"},{"bytes":8478,"name":"publication.md","sha256":"eb766eca0abfdcdb424a629fa85c330eada4b511a815bfa25964172d6533b3af"},{"bytes":8132,"name":"publication.txt","sha256":"de54e1cb9046ca3cf0c6bb538417a907a9833d127e551b6e13ab0d67aaa217e5"},{"bytes":2901,"name":"manifest.json","sha256":"dec9d47595f5fe8d37261044743b9592f7ad1bc9e8c1ef7b5fca17b721f56980"},{"bytes":89,"name":"manifest.sig","sha256":"8d9cdcc83ec86801d8c8f63038fde0ccecf0069d0208e3d97a03359ad9b7a988"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c48c3df69f09fe661f24b112936a3da380d6bf4571bf073cde7ce0ced04c1f5e"}],"publication_id":"OT-2026-000089309"} Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089309
OpenTechnical

OT-2026-000089309

Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
de54e1cb9046ca3cf0c6bb538417a907a9833d127e551b6e13ab0d67aaa217e5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0019]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089309, “Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089309.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089309" title: "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089309" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089309 Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089309 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089309 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089309 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089309", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1168 }, "figures": [], "files": [ { "bytes": 18889, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b13548681e53d72f0237209f443bc4e721bcf28519a21971a8d2f9cbbdea8608" }, { "bytes": 8478, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "eb766eca0abfdcdb424a629fa85c330eada4b511a815bfa25964172d6533b3af" }, { "bytes": 8132, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "de54e1cb9046ca3cf0c6bb538417a907a9833d127e551b6e13ab0d67aaa217e5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089309/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089309", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7d08-85be-2029c70c439b" } txnLfHq7rzZHLMvS5in977NaB8wBFjX9wmW6viTs4yUbaGkJtS6phV/1aqPk0m4KEDwVeYSPPrdZ3QO+vjVKAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: txnLfHq7rzZHLMvS5in977NaB8wBFjX9wmW6viTs4yUbaGkJtS6phV/1aqPk0m4KEDwVeYSPPrdZ3QO+vjVKAQ== {"files":[{"bytes":18636,"name":"index.html","sha256":"76a77ced15bf5f99a5ff2314bea946de33a05e1fc74ad1c0d99ecb741948bc2e"},{"bytes":8268,"name":"publication.md","sha256":"07993b05d1b801a45bf8540a6bd0c36ebb014fa172d68e870ab94873df545bd2"},{"bytes":7922,"name":"publication.txt","sha256":"b258e1866d6217181e82e554dbea3a6511741cc2a6e7933088f40adee8656bac"},{"bytes":2901,"name":"manifest.json","sha256":"8a1da87f8ade479bacd8a6e30b5a8f2abf7cf13d80850623c09311f9eda2912c"},{"bytes":89,"name":"manifest.sig","sha256":"0acc8054b77f74e0479d000e1c5994b6cac662d065278724b9360ea074cb6835"},{"bytes":227,"name":"manifest.sig.txt","sha256":"08a360e2fdf773761478facb55d03ed8c9e8c102da55a2948cbae2e4b66205fd"}],"publication_id":"OT-2026-000089310"} Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089310
OpenTechnical

OT-2026-000089310

Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
b258e1866d6217181e82e554dbea3a6511741cc2a6e7933088f40adee8656bac

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0029]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089310, “Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089310.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089310" title: "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089310" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089310 Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089310 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089310 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089310 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089310", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1133 }, "figures": [], "files": [ { "bytes": 18636, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "76a77ced15bf5f99a5ff2314bea946de33a05e1fc74ad1c0d99ecb741948bc2e" }, { "bytes": 8268, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "07993b05d1b801a45bf8540a6bd0c36ebb014fa172d68e870ab94873df545bd2" }, { "bytes": 7922, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b258e1866d6217181e82e554dbea3a6511741cc2a6e7933088f40adee8656bac" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089310/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089310", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7fff-baeb-f2af4786c9e8" } F2eop/sFWX+/vP5Cla5f9mbuUB659xMEmSGO/dCIgMVcE1nsi40IwF9LHple5geRZtEU/tFma7WUpxMsqGRpDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: F2eop/sFWX+/vP5Cla5f9mbuUB659xMEmSGO/dCIgMVcE1nsi40IwF9LHple5geRZtEU/tFma7WUpxMsqGRpDg== {"files":[{"bytes":18142,"name":"index.html","sha256":"a22246e1ff83c760d065b70462458687aec2f9fa6a6fd988d82c56c3d3be0682"},{"bytes":7790,"name":"publication.md","sha256":"db7a267b1003096079aad98945da94d1e17a7a8e614dedb69e86507fa9ff4562"},{"bytes":7462,"name":"publication.txt","sha256":"e58eacaf6c3254ba4bd2c24b470bc731ba24b6a80dbf45af7f5453efca64a990"},{"bytes":2853,"name":"manifest.json","sha256":"7286822cffe5b8361e249f727c29a3740b9a466e129f9baf6de22482f17d7b70"},{"bytes":89,"name":"manifest.sig","sha256":"a87835b06d4c6b38830d8f5fcc121e2a4d106e1f88cf71c5e3ea6a612ef65d8e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f8e942cd15640b31c02c7246c4511bf290e31c6266144186c96763fe79341db6"}],"publication_id":"OT-2026-000089311"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089311
OpenTechnical

OT-2026-000089311

Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
e58eacaf6c3254ba4bd2c24b470bc731ba24b6a80dbf45af7f5453efca64a990

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089311, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089311.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089311" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089311" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089311 Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089311 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089311 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089311 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089311", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1073 }, "figures": [], "files": [ { "bytes": 18142, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a22246e1ff83c760d065b70462458687aec2f9fa6a6fd988d82c56c3d3be0682" }, { "bytes": 7790, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "db7a267b1003096079aad98945da94d1e17a7a8e614dedb69e86507fa9ff4562" }, { "bytes": 7462, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e58eacaf6c3254ba4bd2c24b470bc731ba24b6a80dbf45af7f5453efca64a990" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089311/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089311", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-77b5-a525-07340db1b5e3" } wSzUb8sljX9tGBfXQDVzrqW+/XfFHVkTiC6AUNvAbaXtJWwSe8wNbU5obiNEfj8HzGT5WejVPFOu1xecysyhAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: wSzUb8sljX9tGBfXQDVzrqW+/XfFHVkTiC6AUNvAbaXtJWwSe8wNbU5obiNEfj8HzGT5WejVPFOu1xecysyhAg== {"files":[{"bytes":18957,"name":"index.html","sha256":"f885b715227b9abfdd4358d7da4af1780d2d2ee2bddaa5be046fa6d99959ff69"},{"bytes":8491,"name":"publication.md","sha256":"fc428db30645894c39d0394d61d6c5dbb6eb9403969adb6e8e6fc2adbf6b80bb"},{"bytes":8157,"name":"publication.txt","sha256":"8f15cdc07dcc80c07ec93c77f2e65bcc1eaf36ceb7223c5a0d5c502eebad3531"},{"bytes":2865,"name":"manifest.json","sha256":"e20ccd53dd80c2bdc3a2ad6636e61336d257aa09095ffe5525d83dc8d0d5387e"},{"bytes":89,"name":"manifest.sig","sha256":"406f3e30af00f812bdc0558f117a650f59847e854e59e2f8eb542b32de2ad407"},{"bytes":227,"name":"manifest.sig.txt","sha256":"838e2347e0c1543a5cb3c1bfff55fc8e0e69ff01d9435af88e7ddac6dd39901c"}],"publication_id":"OT-2026-000089312"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089312
OpenTechnical

OT-2026-000089312

Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8f15cdc07dcc80c07ec93c77f2e65bcc1eaf36ceb7223c5a0d5c502eebad3531

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089312, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089312.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089312" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089312" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089312 Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089312 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089312 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089312 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089312", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1179 }, "figures": [], "files": [ { "bytes": 18957, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f885b715227b9abfdd4358d7da4af1780d2d2ee2bddaa5be046fa6d99959ff69" }, { "bytes": 8491, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fc428db30645894c39d0394d61d6c5dbb6eb9403969adb6e8e6fc2adbf6b80bb" }, { "bytes": 8157, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8f15cdc07dcc80c07ec93c77f2e65bcc1eaf36ceb7223c5a0d5c502eebad3531" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089312/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089312", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7f1c-a7a3-ef426bb4d69c" } b3+lAbiaVeKIim+17XZgrMc5ISr6eR/lxs4p7ZOGz0A0zcutLDcVhZlrh2FzD4tr1ZyHmnumgy50w2si81U5AQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: b3+lAbiaVeKIim+17XZgrMc5ISr6eR/lxs4p7ZOGz0A0zcutLDcVhZlrh2FzD4tr1ZyHmnumgy50w2si81U5AQ== {"files":[{"bytes":18704,"name":"index.html","sha256":"12bbb4a56f77a6c9e3e79134427b70cb6187cf722ca00d9b1d18f785a9b1cb6d"},{"bytes":8281,"name":"publication.md","sha256":"7eccedc998fd871cd534b71917582e99788eaf8c657afa76110a28ce57c76adf"},{"bytes":7947,"name":"publication.txt","sha256":"f231e9115d6b0d673e436a6c3625667d51d61814577709e903a76168cc6e2a4a"},{"bytes":2865,"name":"manifest.json","sha256":"b719f77cbdca4706690cde8b0848a9fd7ec9948fdde5fb8e84aaf16b62c025fd"},{"bytes":89,"name":"manifest.sig","sha256":"0f8f658a29b693d6c4cacc4d306125e498a6fff8d75cd0af19910a5feb53c459"},{"bytes":227,"name":"manifest.sig.txt","sha256":"744f58081b5abca072628b64733428fe162436c2857f83388a45a125d5cd52b9"}],"publication_id":"OT-2026-000089313"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089313
OpenTechnical

OT-2026-000089313

Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f231e9115d6b0d673e436a6c3625667d51d61814577709e903a76168cc6e2a4a

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089313, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089313.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089313" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089313" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089313 Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089313 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089313 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089313 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089313", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1144 }, "figures": [], "files": [ { "bytes": 18704, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "12bbb4a56f77a6c9e3e79134427b70cb6187cf722ca00d9b1d18f785a9b1cb6d" }, { "bytes": 8281, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7eccedc998fd871cd534b71917582e99788eaf8c657afa76110a28ce57c76adf" }, { "bytes": 7947, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f231e9115d6b0d673e436a6c3625667d51d61814577709e903a76168cc6e2a4a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089313/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089313", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7db9-8f04-fb4c72617e95" } cdRpiz8hsrMAwrP0x1ZZMFjkcs8EsMHP6ImOjzKryKvrWYCLlkgHsiXDgT8ndo1Nl5Qg8hF19dW5rm/wA1KSCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: cdRpiz8hsrMAwrP0x1ZZMFjkcs8EsMHP6ImOjzKryKvrWYCLlkgHsiXDgT8ndo1Nl5Qg8hF19dW5rm/wA1KSCA== {"files":[{"bytes":18143,"name":"index.html","sha256":"27d5f6c2f95ab0629f79096a111e2aa4bcdcbfa1c0d00b0a8e0e1dcdb96ef205"},{"bytes":7791,"name":"publication.md","sha256":"92ba2688a777e66c5082f14435c1bc834cadf2e100a90a1a18bcb871b5bd6713"},{"bytes":7463,"name":"publication.txt","sha256":"2f1ca3713159380690bbdfd4c0eda6ce423f2c17fbf88f23220c5f907a030f9f"},{"bytes":2853,"name":"manifest.json","sha256":"6419576fd56ac5ec2cd0ec10e5f15a714309576fa57105e074cff3b4537640f6"},{"bytes":89,"name":"manifest.sig","sha256":"6e5f9a8de4c165829e3f0f5d91f19d7363f3b82d35a1efec12e99561fbad06c7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"68f77d1eaa1dd55a3dafce0e1f8168598ecc8e0223519136398a50d0165529f8"}],"publication_id":"OT-2026-000089314"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089314
OpenTechnical

OT-2026-000089314

Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
2f1ca3713159380690bbdfd4c0eda6ce423f2c17fbf88f23220c5f907a030f9f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089314, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089314.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089314" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089314" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089314 Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089314 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089314 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089314 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089314", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1073 }, "figures": [], "files": [ { "bytes": 18143, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "27d5f6c2f95ab0629f79096a111e2aa4bcdcbfa1c0d00b0a8e0e1dcdb96ef205" }, { "bytes": 7791, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "92ba2688a777e66c5082f14435c1bc834cadf2e100a90a1a18bcb871b5bd6713" }, { "bytes": 7463, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2f1ca3713159380690bbdfd4c0eda6ce423f2c17fbf88f23220c5f907a030f9f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089314/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089314", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7bad-bf7d-43f5fc650b66" } B+au6ecUvkxpdF8ZB8ezOhGGaoZwCfmWM6Oo80UtlmQb8VmK8EfKv7eIqKkeCuBKZsL0SUa8oLO6GVJGDINiDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: B+au6ecUvkxpdF8ZB8ezOhGGaoZwCfmWM6Oo80UtlmQb8VmK8EfKv7eIqKkeCuBKZsL0SUa8oLO6GVJGDINiDg== {"files":[{"bytes":18958,"name":"index.html","sha256":"6ceaa0f0af0e8f01e13b3cc7248c718a621f9d1a2d9a83a755efdcb3008fec1a"},{"bytes":8492,"name":"publication.md","sha256":"7395b4e552069a3a0fcfc50f33b4fc4d396a2ac5b51173f7e101f48e3e273b89"},{"bytes":8158,"name":"publication.txt","sha256":"d4fa1131b02806a3c93d6d8d5db3248558dd6243cfb1ff977619ddba1510a03a"},{"bytes":2865,"name":"manifest.json","sha256":"88ce3c205e1a135f532722e9683cf4424306f66f72c62f5def9b30f29e3f579c"},{"bytes":89,"name":"manifest.sig","sha256":"611a1e5e7297efd25609949850fe9063b9d528e414e5cfc876d496139ce69d9c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2d04b64a308c99ff43ea6ea5215f6e48eee712f28ee5e6e33539dd74b457358e"}],"publication_id":"OT-2026-000089315"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089315
OpenTechnical

OT-2026-000089315

Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
d4fa1131b02806a3c93d6d8d5db3248558dd6243cfb1ff977619ddba1510a03a

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089315, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089315.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089315" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089315" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089315 Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089315 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089315 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089315 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089315", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1179 }, "figures": [], "files": [ { "bytes": 18958, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6ceaa0f0af0e8f01e13b3cc7248c718a621f9d1a2d9a83a755efdcb3008fec1a" }, { "bytes": 8492, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7395b4e552069a3a0fcfc50f33b4fc4d396a2ac5b51173f7e101f48e3e273b89" }, { "bytes": 8158, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d4fa1131b02806a3c93d6d8d5db3248558dd6243cfb1ff977619ddba1510a03a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089315/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089315", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-70c4-8daf-8f014445c649" } ThTeEgFnxh6bbzB+k5CkqyLgviAP6TK2kPbM4wclv1/PzKNQmK0CQ3hyb86bIT7eNTqX+IRvj9aZ9ComMuhlAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ThTeEgFnxh6bbzB+k5CkqyLgviAP6TK2kPbM4wclv1/PzKNQmK0CQ3hyb86bIT7eNTqX+IRvj9aZ9ComMuhlAg== {"files":[{"bytes":18705,"name":"index.html","sha256":"ae4c21a6d32a56ec0217ea56c84afdc588572e565dab88fcd2c9f10a33dcfce3"},{"bytes":8282,"name":"publication.md","sha256":"1eb3f9d1bbc6f26badab839cb8066d1a1bf025e6eae49264a69acb72aba25f62"},{"bytes":7948,"name":"publication.txt","sha256":"57e04209c50457b776baa1ef4495e76b4a899e2933935a2170c7fd6238d86e76"},{"bytes":2865,"name":"manifest.json","sha256":"fb56912e702fb00a0973d61fa1d6e04d23b2993a5c31721c115d7103ce931e6d"},{"bytes":89,"name":"manifest.sig","sha256":"83ecc79cad1dac30acb0b863671375548308203d9171dfe7a0934f203a2ea11d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"10356a44e33c681d5c1a30499ca2c1b4123aef6fb6d58f64bda69796277144b3"}],"publication_id":"OT-2026-000089316"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089316
OpenTechnical

OT-2026-000089316

Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
57e04209c50457b776baa1ef4495e76b4a899e2933935a2170c7fd6238d86e76

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089316, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089316.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089316" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089316" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089316 Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089316 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089316 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089316 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089316", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1144 }, "figures": [], "files": [ { "bytes": 18705, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ae4c21a6d32a56ec0217ea56c84afdc588572e565dab88fcd2c9f10a33dcfce3" }, { "bytes": 8282, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1eb3f9d1bbc6f26badab839cb8066d1a1bf025e6eae49264a69acb72aba25f62" }, { "bytes": 7948, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "57e04209c50457b776baa1ef4495e76b4a899e2933935a2170c7fd6238d86e76" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089316/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089316", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7ae6-afd1-d2e7e3f1b441" } bvu97eRDhHYZ+XOyxMz0p/L/jJsys85qadnh+8FecVc8D2IN0WAgka6eM/dbZVNN5iSv8qct1r9OekRvt38FAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: bvu97eRDhHYZ+XOyxMz0p/L/jJsys85qadnh+8FecVc8D2IN0WAgka6eM/dbZVNN5iSv8qct1r9OekRvt38FAQ== {"files":[{"bytes":18147,"name":"index.html","sha256":"bbaf7186447cf0e43b49ae51d82fd90aa49c2aa241edfc5076109696ceaebd9b"},{"bytes":7795,"name":"publication.md","sha256":"f629f75250ca37c56f39e47865effd1bc016ae50c8c22142204c2ddc6104cf6b"},{"bytes":7467,"name":"publication.txt","sha256":"9dd9d35a6e40967081405b22e59e96d7d1fa9e8b1c3139812907ac8cbb54b810"},{"bytes":2853,"name":"manifest.json","sha256":"f384b62ddef228a7010ae9b8a465b3647e03a92c5c7be99420deefde02785a76"},{"bytes":89,"name":"manifest.sig","sha256":"c4e6903532b730cd79e292cf19cb532271e2010036a03d05d7f2dd2b8d3ff391"},{"bytes":227,"name":"manifest.sig.txt","sha256":"474f0fa84f785e147c9ee3b605c884fa6481412900bd0daa82b1777d9a33d39d"}],"publication_id":"OT-2026-000089317"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089317
OpenTechnical

OT-2026-000089317

Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
9dd9d35a6e40967081405b22e59e96d7d1fa9e8b1c3139812907ac8cbb54b810

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089317, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089317.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089317" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089317" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089317 Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089317 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089317 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089317 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089317", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1073 }, "figures": [], "files": [ { "bytes": 18147, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bbaf7186447cf0e43b49ae51d82fd90aa49c2aa241edfc5076109696ceaebd9b" }, { "bytes": 7795, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f629f75250ca37c56f39e47865effd1bc016ae50c8c22142204c2ddc6104cf6b" }, { "bytes": 7467, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9dd9d35a6e40967081405b22e59e96d7d1fa9e8b1c3139812907ac8cbb54b810" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089317/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089317", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7398-bebd-eba80ae1de2d" } mjJ8z8GkeA66LNzWdPxikSPWCU7FDAeDx5BkM9l+4lZC6GFz1L1+OWz8IVm/8Yfc/McJKI4M75GlT6aMgHstAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: mjJ8z8GkeA66LNzWdPxikSPWCU7FDAeDx5BkM9l+4lZC6GFz1L1+OWz8IVm/8Yfc/McJKI4M75GlT6aMgHstAw== {"files":[{"bytes":18962,"name":"index.html","sha256":"80809df289564ddc87340123615a780a649637f72eb43a11f67b41b1c74bca62"},{"bytes":8496,"name":"publication.md","sha256":"01d8aba534dbcb47225ca5839ea49c138d4f33f055b2957ada5f23489959b852"},{"bytes":8162,"name":"publication.txt","sha256":"ff6181284b8600839dd6d4627acd761587510ef06a0c422be184f96923bf1ddc"},{"bytes":2865,"name":"manifest.json","sha256":"b27d88bd0d760b76adb015462e4c48311ab6853a1be4305be1242333d469b26e"},{"bytes":89,"name":"manifest.sig","sha256":"413f0ce92fc3ed349ecaf3b1e8c7b0672bc69354d603d7cb92691e3269a947a2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"66a8d1b4503262f54b6cdfd9828f210648f30984c75b31020f152899f7b200db"}],"publication_id":"OT-2026-000089318"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089318
OpenTechnical

OT-2026-000089318

Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
ff6181284b8600839dd6d4627acd761587510ef06a0c422be184f96923bf1ddc

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089318, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089318.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089318" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089318" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089318 Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089318 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089318 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089318 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089318", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1179 }, "figures": [], "files": [ { "bytes": 18962, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "80809df289564ddc87340123615a780a649637f72eb43a11f67b41b1c74bca62" }, { "bytes": 8496, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "01d8aba534dbcb47225ca5839ea49c138d4f33f055b2957ada5f23489959b852" }, { "bytes": 8162, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ff6181284b8600839dd6d4627acd761587510ef06a0c422be184f96923bf1ddc" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089318/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089318", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7206-8f4a-5d5c4f1324c1" } VTP/jm+Ym+jRWw/Vn93xCxr0fFRye9fCuM78Sk1x2tv4gyyPjmAPDp2f6mRTO/Y/HSY+/04EhYbEYQp6hVboAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: VTP/jm+Ym+jRWw/Vn93xCxr0fFRye9fCuM78Sk1x2tv4gyyPjmAPDp2f6mRTO/Y/HSY+/04EhYbEYQp6hVboAg== {"files":[{"bytes":18709,"name":"index.html","sha256":"f34d7f444ce273bab7d662b91707ec6420fe46aeeeae9c30dc62308af86bd3ce"},{"bytes":8286,"name":"publication.md","sha256":"610dc5e62856ab20640c4c61693a269303f5842b904c60cb7dc2e309029f270d"},{"bytes":7952,"name":"publication.txt","sha256":"f43e9548e39231981a4928557493cb3aa779ec4aea801785e78d88e91eed32bd"},{"bytes":2865,"name":"manifest.json","sha256":"9322fc201b4ba96731cd9ad9061b9800fced713ecb64fc58a21270916db42e09"},{"bytes":89,"name":"manifest.sig","sha256":"fba63219e48e72067003cb322b3edf46856236ad0a41b152ed822e29331a9f0d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"fca4a510f6443c8c58bd22f0dccf6c28d0058183c8de67c762e7989239bb3b10"}],"publication_id":"OT-2026-000089319"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089319
OpenTechnical

OT-2026-000089319

Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f43e9548e39231981a4928557493cb3aa779ec4aea801785e78d88e91eed32bd

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089319, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089319.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089319" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089319" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089319 Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089319 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089319 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089319 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089319", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1144 }, "figures": [], "files": [ { "bytes": 18709, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f34d7f444ce273bab7d662b91707ec6420fe46aeeeae9c30dc62308af86bd3ce" }, { "bytes": 8286, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "610dc5e62856ab20640c4c61693a269303f5842b904c60cb7dc2e309029f270d" }, { "bytes": 7952, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f43e9548e39231981a4928557493cb3aa779ec4aea801785e78d88e91eed32bd" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089319/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089319", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7c0a-9886-e17651d3c49e" } 9j77a8ZnIDMiJSr71Bj4YC/1SVZ7er2X1kxNnlbflxigzgj4jBNT3SF73+lCS7ZOWWLU/tmY4tD70YPgsTmADg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 9j77a8ZnIDMiJSr71Bj4YC/1SVZ7er2X1kxNnlbflxigzgj4jBNT3SF73+lCS7ZOWWLU/tmY4tD70YPgsTmADg== {"files":[{"bytes":18336,"name":"index.html","sha256":"41e5b8182c8361935dcda941ac947fbde5d715dc09a287e8fe5e5644ee06c2a8"},{"bytes":7952,"name":"publication.md","sha256":"ca0fbf691e2674afe654da39bf46cb90f6ce8c6167a53c3075ed395a3145c578"},{"bytes":7634,"name":"publication.txt","sha256":"20cb06c50c2715c49c4a0fa2d265a603b6caed44b55944403af9abb47d0bc0e6"},{"bytes":2832,"name":"manifest.json","sha256":"28d4f0de0ab0d537f0fe954560b26a8f43077a1d421ef9487be264b7bb852d19"},{"bytes":89,"name":"manifest.sig","sha256":"66171210dd06aef6393577aa026b7ba90ffb42980c5836db2b9d7ce3f50d43ef"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b4902f9f649d7d6d7fafbb8cd44234edc4d130d79b3f4438fbb3d4f38bf448cb"}],"publication_id":"OT-2026-000089320"} Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089320
OpenTechnical

OT-2026-000089320

Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
20cb06c50c2715c49c4a0fa2d265a603b6caed44b55944403af9abb47d0bc0e6

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089320, “Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089320.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089320" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089320" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089320 Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089320 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089320 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089320 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089320", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1113 }, "figures": [], "files": [ { "bytes": 18336, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "41e5b8182c8361935dcda941ac947fbde5d715dc09a287e8fe5e5644ee06c2a8" }, { "bytes": 7952, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ca0fbf691e2674afe654da39bf46cb90f6ce8c6167a53c3075ed395a3145c578" }, { "bytes": 7634, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "20cb06c50c2715c49c4a0fa2d265a603b6caed44b55944403af9abb47d0bc0e6" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089320/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089320", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7d0e-993c-4d65417ddbf9" } SkXPOpPozefFbmrvB0RXAH/ILNt1RO3yDDk5wgIWYEostCr7wZITFzysvVnHe+QHIs13mh69SaIPifnrXKrhCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: SkXPOpPozefFbmrvB0RXAH/ILNt1RO3yDDk5wgIWYEostCr7wZITFzysvVnHe+QHIs13mh69SaIPifnrXKrhCQ== {"files":[{"bytes":19151,"name":"index.html","sha256":"c718a9f8c9a40c6bc90639320dfe8882deaf1a6510000c6ad532534b0f550aae"},{"bytes":8653,"name":"publication.md","sha256":"ae79fd1fcadf418cf6f16a28e63e46009ac71d7a83ef7da114e65df03f83ba26"},{"bytes":8329,"name":"publication.txt","sha256":"6320d103e4a7736ab31cbadd6d6d3bdb1e11ad7a9ab6878a674a3ca8ef078a93"},{"bytes":2844,"name":"manifest.json","sha256":"eafed296fc7feb754ae86a14226a7bd7bd7adf3cad3c9fe6c3304a95f04414c6"},{"bytes":89,"name":"manifest.sig","sha256":"0b99714a26e36e8d2302a294ad368af9f6dcf942bc1f8161af898f742ba08740"},{"bytes":227,"name":"manifest.sig.txt","sha256":"150a45765e71ef20a789ad7584a2ccfcf4e2c547ef9c98ffca642f0cb4e458cd"}],"publication_id":"OT-2026-000089321"} Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089321
OpenTechnical

OT-2026-000089321

Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
6320d103e4a7736ab31cbadd6d6d3bdb1e11ad7a9ab6878a674a3ca8ef078a93

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089321, “Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089321.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089321" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089321" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089321 Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089321 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089321 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089321 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089321", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1219 }, "figures": [], "files": [ { "bytes": 19151, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c718a9f8c9a40c6bc90639320dfe8882deaf1a6510000c6ad532534b0f550aae" }, { "bytes": 8653, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ae79fd1fcadf418cf6f16a28e63e46009ac71d7a83ef7da114e65df03f83ba26" }, { "bytes": 8329, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "6320d103e4a7736ab31cbadd6d6d3bdb1e11ad7a9ab6878a674a3ca8ef078a93" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089321/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089321", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7465-b26d-872db2a7ccd9" } pkX9kg1MyrlQp8/xPjWOra5JhwC6yeO0ukDbTSqFOmVjvnTJnFca6Bju1B5duMsKu1q/pjUBRRGw1vDvJq2gBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: pkX9kg1MyrlQp8/xPjWOra5JhwC6yeO0ukDbTSqFOmVjvnTJnFca6Bju1B5duMsKu1q/pjUBRRGw1vDvJq2gBw== {"files":[{"bytes":18898,"name":"index.html","sha256":"7797b7389c202db8587f7e4b6e44a0fe2b771d1e295dce8d8bb0f7a39d9ec286"},{"bytes":8443,"name":"publication.md","sha256":"38d63574662bfa781b592e11e2eadf8077eec1114793cc961d30bcb8d9505bf0"},{"bytes":8119,"name":"publication.txt","sha256":"9c2a3e4e22f9b897a74492bf2b39a42cc673298f8845a36df081cc3720f72467"},{"bytes":2844,"name":"manifest.json","sha256":"5b20a1eaddbcde1cbeb198bf193ebbcc450aaa84af755bb6e0736ee4c8e46d6f"},{"bytes":89,"name":"manifest.sig","sha256":"6ab396170003c3e11bfcc40fb9d59bc7754a8edcba75b8971d1e6763a328b884"},{"bytes":227,"name":"manifest.sig.txt","sha256":"56f6ea84700d20bdba73a6a744761a2d124fbd35fd7eed7a234e0097b865aacc"}],"publication_id":"OT-2026-000089322"} Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089322
OpenTechnical

OT-2026-000089322

Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
9c2a3e4e22f9b897a74492bf2b39a42cc673298f8845a36df081cc3720f72467

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089322, “Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089322.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089322" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089322" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089322 Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089322 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089322 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089322 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089322", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1184 }, "figures": [], "files": [ { "bytes": 18898, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7797b7389c202db8587f7e4b6e44a0fe2b771d1e295dce8d8bb0f7a39d9ec286" }, { "bytes": 8443, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "38d63574662bfa781b592e11e2eadf8077eec1114793cc961d30bcb8d9505bf0" }, { "bytes": 8119, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9c2a3e4e22f9b897a74492bf2b39a42cc673298f8845a36df081cc3720f72467" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089322/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089322", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7b04-9087-8dfcba8b6b0e" } xuVHrFA/HvhKTcGu8iomwJDDqlXLGNqzVOr5yKE8fHwYfLiQXN+7SYFeRLaOWYlhZRZP0yXD8hv0xaDh1ncoBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: xuVHrFA/HvhKTcGu8iomwJDDqlXLGNqzVOr5yKE8fHwYfLiQXN+7SYFeRLaOWYlhZRZP0yXD8hv0xaDh1ncoBw== {"files":[{"bytes":18282,"name":"index.html","sha256":"2019538f1eaaad4895fac646b22419b256a54a5e9185a096c925f34709508a33"},{"bytes":7898,"name":"publication.md","sha256":"bdcb9ef44d98e71565c6baa622432a6ff70dfcc7b55141e5338a157ec5981c47"},{"bytes":7580,"name":"publication.txt","sha256":"36b617a181b9aed7a587e3c31b5e800727aa590810f3cb791dea5f299318d808"},{"bytes":2832,"name":"manifest.json","sha256":"ebba2d18008bf6ad4a305b683ebcaeccfa6e3bc3a30f183bb0c3c4688762fa63"},{"bytes":89,"name":"manifest.sig","sha256":"d0b70b9cea2284ded97f035bb3b7ad5aed24cb59630a4e046c6090739bc9282f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e584335b692ead1a1ae88e005106856ef0c50540856d0d33b315dd7ea31147ee"}],"publication_id":"OT-2026-000089323"} Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089323
OpenTechnical

OT-2026-000089323

Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
36b617a181b9aed7a587e3c31b5e800727aa590810f3cb791dea5f299318d808

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089323, “Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089323.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089323" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089323" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089323 Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089323 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089323 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089323 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089323", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1098 }, "figures": [], "files": [ { "bytes": 18282, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2019538f1eaaad4895fac646b22419b256a54a5e9185a096c925f34709508a33" }, { "bytes": 7898, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "bdcb9ef44d98e71565c6baa622432a6ff70dfcc7b55141e5338a157ec5981c47" }, { "bytes": 7580, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "36b617a181b9aed7a587e3c31b5e800727aa590810f3cb791dea5f299318d808" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089323/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089323", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-71fe-9c39-ef8ac9e5125c" } h15S54JOVW9iDUCWWErZgX7mqRJBsk1I6YO00hHsdudXxlnn3565PjHu37XJLnp0FBOtBlnhNOcVq3jKgrrAAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: h15S54JOVW9iDUCWWErZgX7mqRJBsk1I6YO00hHsdudXxlnn3565PjHu37XJLnp0FBOtBlnhNOcVq3jKgrrAAA== {"files":[{"bytes":19097,"name":"index.html","sha256":"1081729236f751efdf0f8c9631f6eb328101083cd923e521c15f5567ab9fb41b"},{"bytes":8599,"name":"publication.md","sha256":"38d4487aebd98be8527d919d5abd3bf98b5509f7acda4daaa4c1bd6dd40c3196"},{"bytes":8275,"name":"publication.txt","sha256":"a34d216c7fad6137d3f68172051806566683ff867115023d5bdf6b310883089c"},{"bytes":2844,"name":"manifest.json","sha256":"11fca408f339d350a88a7747f11909e81b9a2991a087df9a045e1be08de7072c"},{"bytes":89,"name":"manifest.sig","sha256":"ab0f392db8149065e3eb1b34448c8fc533bfddde8afaa095c03251710e7a1a7f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a7e98b4f2ba995ea5a7cfda8d56a54324404dcf3211988d5436ca74010d7caae"}],"publication_id":"OT-2026-000089324"} Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089324
OpenTechnical

OT-2026-000089324

Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a34d216c7fad6137d3f68172051806566683ff867115023d5bdf6b310883089c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089324, “Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089324.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089324" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089324" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089324 Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089324 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089324 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089324 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089324", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1204 }, "figures": [], "files": [ { "bytes": 19097, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1081729236f751efdf0f8c9631f6eb328101083cd923e521c15f5567ab9fb41b" }, { "bytes": 8599, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "38d4487aebd98be8527d919d5abd3bf98b5509f7acda4daaa4c1bd6dd40c3196" }, { "bytes": 8275, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a34d216c7fad6137d3f68172051806566683ff867115023d5bdf6b310883089c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089324/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089324", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7c5d-946e-8431ac111cb7" } bXEy00j4hDJJI1ZxUau4Cc5F+2kol+tm5tbO4tL9K3MhOq1dzRCwdTPgURzHImBSIOaf81OLGGldnxdYiV0XAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: bXEy00j4hDJJI1ZxUau4Cc5F+2kol+tm5tbO4tL9K3MhOq1dzRCwdTPgURzHImBSIOaf81OLGGldnxdYiV0XAw== {"files":[{"bytes":18844,"name":"index.html","sha256":"814bbc7915a39aa6513cf42b257cb7b11b374ac61522ad6bbeee4c9815f266d4"},{"bytes":8389,"name":"publication.md","sha256":"cbc30b3ac03de244a87f9d3cdab8d986f4503bac7cf55e9cea688dfda3b4ccbc"},{"bytes":8065,"name":"publication.txt","sha256":"8178c31863095f318cef1cdabe240485b82b7173fba689309a28ea7e24667e5b"},{"bytes":2844,"name":"manifest.json","sha256":"64008bb1cbfc390a37f6d4134f882253db3cfde62c8b8c3d6a73d63d1b468b2b"},{"bytes":89,"name":"manifest.sig","sha256":"23cd1b14de17b23a7aac28afe66d82bd20e06bc5ccca0d7614e7b700678dbbd5"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3edf1ec6ae062f885082e0375c6101fed164dbebfea7103005da52f38a4e5049"}],"publication_id":"OT-2026-000089325"} Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089325
OpenTechnical

OT-2026-000089325

Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8178c31863095f318cef1cdabe240485b82b7173fba689309a28ea7e24667e5b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089325, “Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089325.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089325" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089325" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089325 Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089325 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089325 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089325 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089325", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1169 }, "figures": [], "files": [ { "bytes": 18844, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "814bbc7915a39aa6513cf42b257cb7b11b374ac61522ad6bbeee4c9815f266d4" }, { "bytes": 8389, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cbc30b3ac03de244a87f9d3cdab8d986f4503bac7cf55e9cea688dfda3b4ccbc" }, { "bytes": 8065, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8178c31863095f318cef1cdabe240485b82b7173fba689309a28ea7e24667e5b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089325/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089325", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7b35-9d81-e9e26354d87c" } qrjLWUlQQNaxt4t+bbHsTn/hVubmExXuPaMalpOGFygr0EWE5eTsKG/7S+sIe+YlHmgCJxnMzqgvV0HT676pAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: qrjLWUlQQNaxt4t+bbHsTn/hVubmExXuPaMalpOGFygr0EWE5eTsKG/7S+sIe+YlHmgCJxnMzqgvV0HT676pAg== {"files":[{"bytes":18036,"name":"index.html","sha256":"b517cdff1ea7e6fed2f9fbda96645cac3bcec72124db12c0228b021794f09dbf"},{"bytes":7700,"name":"publication.md","sha256":"25b65b927b2ffa7273e75af8dd70015dce3ff990bd0c94c1cbc88e8199ae96ac"},{"bytes":7380,"name":"publication.txt","sha256":"0724428971675de0e1309a3c7875cd24aa0cb491f9d942ac73719b46a885347e"},{"bytes":2845,"name":"manifest.json","sha256":"e8eec27fab792adb5de30725941198c0c341a884f21579067f8deba5dbbacc5a"},{"bytes":89,"name":"manifest.sig","sha256":"3717e77200f9e875ce3be23b15943490e2f8867ea1804d1534931611c2b3a507"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b7fc5b5039661ae9ee8106d5b8477f24f85bf8b9f295b77ed99f08c7be32370a"}],"publication_id":"OT-2026-000089326"} Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089326
OpenTechnical

OT-2026-000089326

Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
0724428971675de0e1309a3c7875cd24aa0cb491f9d942ac73719b46a885347e

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089326, “Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089326.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089326" title: "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089326" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089326 Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089326 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089326 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089326 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089326", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1061 }, "figures": [], "files": [ { "bytes": 18036, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b517cdff1ea7e6fed2f9fbda96645cac3bcec72124db12c0228b021794f09dbf" }, { "bytes": 7700, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "25b65b927b2ffa7273e75af8dd70015dce3ff990bd0c94c1cbc88e8199ae96ac" }, { "bytes": 7380, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0724428971675de0e1309a3c7875cd24aa0cb491f9d942ac73719b46a885347e" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089326/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089326", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7106-b2c1-9617b1dc5607" } 4zppR+v/IgmUmzQjqp8h3452LOYeFRR/7mXKmD3UlobJxzoX1bfyBKxH6+lW/DScTRXh0rfKa/7XlXnT0hYFBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 4zppR+v/IgmUmzQjqp8h3452LOYeFRR/7mXKmD3UlobJxzoX1bfyBKxH6+lW/DScTRXh0rfKa/7XlXnT0hYFBg== {"files":[{"bytes":18851,"name":"index.html","sha256":"6de8a618142b6d608609044635147052955a485cb541eb5a1a8cdc14596ce375"},{"bytes":8401,"name":"publication.md","sha256":"702349200453b015fd5cdb8be67d2716e556a49dcb68c0cee29311453288f344"},{"bytes":8075,"name":"publication.txt","sha256":"05a8d75d996fada134bf28efcd914b76759f57aaf661e6a0c83f0a3da51507f5"},{"bytes":2857,"name":"manifest.json","sha256":"66e2da9cf40e4f12015391dbd2fe10c75f9147516d02f68b799cd62cd978da71"},{"bytes":89,"name":"manifest.sig","sha256":"1477917464acf7eb90c180a7b758e79d440b5613f05f666f047e0f0d77df8838"},{"bytes":227,"name":"manifest.sig.txt","sha256":"95ebe58abf7e4f9905e8484dbe49b670c4e0c212ef54237357db9f9a7babb045"}],"publication_id":"OT-2026-000089327"} Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089327
OpenTechnical

OT-2026-000089327

Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
05a8d75d996fada134bf28efcd914b76759f57aaf661e6a0c83f0a3da51507f5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089327, “Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089327.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089327" title: "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089327" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089327 Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089327 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089327 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089327 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089327", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1167 }, "figures": [], "files": [ { "bytes": 18851, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6de8a618142b6d608609044635147052955a485cb541eb5a1a8cdc14596ce375" }, { "bytes": 8401, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "702349200453b015fd5cdb8be67d2716e556a49dcb68c0cee29311453288f344" }, { "bytes": 8075, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "05a8d75d996fada134bf28efcd914b76759f57aaf661e6a0c83f0a3da51507f5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089327/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089327", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7d0e-9dd4-4cb2fd044f9a" } 3ohNt/1by6ihNYFH7HG9swa+61AC1kUYmFmN32JJlaFrp0VIeQXFvqQBW/KeknZ+WdajlzVFIDDTHXWU4zXQCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 3ohNt/1by6ihNYFH7HG9swa+61AC1kUYmFmN32JJlaFrp0VIeQXFvqQBW/KeknZ+WdajlzVFIDDTHXWU4zXQCA== {"files":[{"bytes":18598,"name":"index.html","sha256":"bb274186bd16f2cdb665c37cac64050ab8c32a021fe4cd3f696fba031becdef1"},{"bytes":8191,"name":"publication.md","sha256":"9282c9dc508dc61b4fc26c96a7d1f80d0c4534b39574f96a8d0697d378276f4a"},{"bytes":7865,"name":"publication.txt","sha256":"45bb7de3a090cd6337f83432716b286736425f59c5a768ee93c9e24cb1526e8a"},{"bytes":2857,"name":"manifest.json","sha256":"66e03af08a6a6430c60543dea3d1fe068632cc3b19951ce61a0bbb93c1e6bafd"},{"bytes":89,"name":"manifest.sig","sha256":"aa4e23dd09e2d8fbddab3357e5cd7d20aba5ccc40709b9dcc3a98fbd2d27849c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c2666dff3dff0da01443d216b52305c6a32535520cae5119115985dbc49d8559"}],"publication_id":"OT-2026-000089328"} Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089328
OpenTechnical

OT-2026-000089328

Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
45bb7de3a090cd6337f83432716b286736425f59c5a768ee93c9e24cb1526e8a

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089328, “Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089328.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089328" title: "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089328" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089328 Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089328 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089328 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089328 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089328", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1132 }, "figures": [], "files": [ { "bytes": 18598, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bb274186bd16f2cdb665c37cac64050ab8c32a021fe4cd3f696fba031becdef1" }, { "bytes": 8191, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9282c9dc508dc61b4fc26c96a7d1f80d0c4534b39574f96a8d0697d378276f4a" }, { "bytes": 7865, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "45bb7de3a090cd6337f83432716b286736425f59c5a768ee93c9e24cb1526e8a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089328/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089328", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-79c3-ae38-4326cdb13b3e" } LO6boyd8V6qtS6Lp6qRW3Duh/oGPCgwEYzU0TbWRJDMOUzMpTDDhngQEIda8EogADcX7sjUcBILpvXiomKbDBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: LO6boyd8V6qtS6Lp6qRW3Duh/oGPCgwEYzU0TbWRJDMOUzMpTDDhngQEIda8EogADcX7sjUcBILpvXiomKbDBQ== {"files":[{"bytes":18036,"name":"index.html","sha256":"0c2338a2e4b0fd4d6d814c3915b41c886e8408002a6a65a655104e8da0a953f8"},{"bytes":7700,"name":"publication.md","sha256":"c5550ecfec1445793818e769a337b01b42221d59ea30f64d9f7c90fd252a14cb"},{"bytes":7380,"name":"publication.txt","sha256":"cd9539dc3afb3c2293ac7057e007db7d8537de6bbdd8d02dbc2fa8a46afb66c9"},{"bytes":2845,"name":"manifest.json","sha256":"574cdc990b39b31183acbd3cb99ba98cdae8e4940da533cb30d545cacf6dbcb9"},{"bytes":89,"name":"manifest.sig","sha256":"7edccf5e791f8de19627850b7892a5f36161b2aa7e5f69ea0d223051caa45992"},{"bytes":227,"name":"manifest.sig.txt","sha256":"91817d03bbf4f1602bbe83d8ea2ea2e58d3542fd9ca45598dfa43f6bf262018e"}],"publication_id":"OT-2026-000089329"} Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089329
OpenTechnical

OT-2026-000089329

Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
cd9539dc3afb3c2293ac7057e007db7d8537de6bbdd8d02dbc2fa8a46afb66c9

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089329, “Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089329.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089329" title: "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089329" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089329 Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089329 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089329 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089329 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089329", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1061 }, "figures": [], "files": [ { "bytes": 18036, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0c2338a2e4b0fd4d6d814c3915b41c886e8408002a6a65a655104e8da0a953f8" }, { "bytes": 7700, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c5550ecfec1445793818e769a337b01b42221d59ea30f64d9f7c90fd252a14cb" }, { "bytes": 7380, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cd9539dc3afb3c2293ac7057e007db7d8537de6bbdd8d02dbc2fa8a46afb66c9" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089329/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089329", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7905-a1eb-b3b1c073d773" } akm/HVxqzbtr0jjvmtX/5C6fnCxWIghPIcBIMD5L3V33vtfDEaS9FGTS7Z5eBPTtb8h2S8IqINo3EcrtsShaBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: akm/HVxqzbtr0jjvmtX/5C6fnCxWIghPIcBIMD5L3V33vtfDEaS9FGTS7Z5eBPTtb8h2S8IqINo3EcrtsShaBA== {"files":[{"bytes":18851,"name":"index.html","sha256":"74e2ecd80e29c7bc803de5eb00a51fc59b0e04cf34d44dac5cfcf55a1bf23159"},{"bytes":8401,"name":"publication.md","sha256":"a9a6c740399d6fed6f00efd2468467a7e3a92b18d5720dce5edcac0ebbd24fca"},{"bytes":8075,"name":"publication.txt","sha256":"c5ff5f9e9552ad492b828e1fa5f9f37c9c39bcfe3b3a77f3b3549153bd4b55de"},{"bytes":2857,"name":"manifest.json","sha256":"58f53800634848278aa1db6a968d6e191b4ee5ae947b29b97d709e749b66b56e"},{"bytes":89,"name":"manifest.sig","sha256":"a73f5300f28a1f381cf24b49db5b43b2a8236164a2834069776c460d5f4f4b45"},{"bytes":227,"name":"manifest.sig.txt","sha256":"77999d174e395c528c62c8ec4eb23bfcdcd7cd1afeed1a0b0a0702054e67741d"}],"publication_id":"OT-2026-000089330"} Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089330
OpenTechnical

OT-2026-000089330

Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c5ff5f9e9552ad492b828e1fa5f9f37c9c39bcfe3b3a77f3b3549153bd4b55de

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089330, “Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089330.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089330" title: "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089330" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089330 Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089330 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089330 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089330 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089330", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1167 }, "figures": [], "files": [ { "bytes": 18851, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "74e2ecd80e29c7bc803de5eb00a51fc59b0e04cf34d44dac5cfcf55a1bf23159" }, { "bytes": 8401, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a9a6c740399d6fed6f00efd2468467a7e3a92b18d5720dce5edcac0ebbd24fca" }, { "bytes": 8075, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c5ff5f9e9552ad492b828e1fa5f9f37c9c39bcfe3b3a77f3b3549153bd4b55de" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089330/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089330", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7945-aaec-5517935fcc74" } yzcvmiTwPQlVx21AKJjx5/enfxnvzsok7U0idJPHAab5qU6QIgeMJJQWUMOaasRtTlithIPWc2DvvJjBuN4YAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: yzcvmiTwPQlVx21AKJjx5/enfxnvzsok7U0idJPHAab5qU6QIgeMJJQWUMOaasRtTlithIPWc2DvvJjBuN4YAg== {"files":[{"bytes":18598,"name":"index.html","sha256":"7f1d2c95d099a5c6a0903d7b620f6eebd1a210b1c95a451d7ea73b33942f0162"},{"bytes":8191,"name":"publication.md","sha256":"0a9d7ab38a1a144267697bb2268801683ed75df870717d78bc61d84926172205"},{"bytes":7865,"name":"publication.txt","sha256":"5a3d6db5bbace4f6e4580bc178835ea5dbb67b4fff5afea439688aafa9f63b1f"},{"bytes":2857,"name":"manifest.json","sha256":"495ddbb438fd54d8a67853dcc3fddc9fba75545d9c6b84f425820f3a145f7bc3"},{"bytes":89,"name":"manifest.sig","sha256":"cd7fd50bf6b0d25d8792ee9954ad26844474877eee1c27c3dc068a33eecef493"},{"bytes":227,"name":"manifest.sig.txt","sha256":"72e58fc013aa4deb741d54afed85c888030c6249cdd8b3491da6df206fbfad52"}],"publication_id":"OT-2026-000089331"} Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089331
OpenTechnical

OT-2026-000089331

Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
5a3d6db5bbace4f6e4580bc178835ea5dbb67b4fff5afea439688aafa9f63b1f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089331, “Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089331.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089331" title: "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089331" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089331 Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089331 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089331 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089331 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089331", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1132 }, "figures": [], "files": [ { "bytes": 18598, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7f1d2c95d099a5c6a0903d7b620f6eebd1a210b1c95a451d7ea73b33942f0162" }, { "bytes": 8191, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0a9d7ab38a1a144267697bb2268801683ed75df870717d78bc61d84926172205" }, { "bytes": 7865, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5a3d6db5bbace4f6e4580bc178835ea5dbb67b4fff5afea439688aafa9f63b1f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089331/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089331", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-72ec-a799-66038bec0cc8" } z5IxOKqqvOwmb7U4HJfnIpAwR0gN7ETEKPykRVH1LZmdTwkqaBu6MLM5pAkPP9cHDs5ExIJJ8jJDJ9BUM4fAAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: z5IxOKqqvOwmb7U4HJfnIpAwR0gN7ETEKPykRVH1LZmdTwkqaBu6MLM5pAkPP9cHDs5ExIJJ8jJDJ9BUM4fAAg== {"files":[{"bytes":18426,"name":"index.html","sha256":"bf61958dfbab36d5b723575a1cdb08712906dafcf849a9c81794ab65baa22f2b"},{"bytes":7999,"name":"publication.md","sha256":"601ac3ae7ef26b33aa8ce299ee00ef9a9d6b9e17fdc1ff465967d57d8444f95a"},{"bytes":7661,"name":"publication.txt","sha256":"7418d06de71c64eb1d89ae6f9c0586e51d6d67c59c1a7bb12dc2f43cc9f7327a"},{"bytes":2855,"name":"manifest.json","sha256":"6d2ebd3e16a2bb8a92e6ced9081266f66ce6ab2457cadc7d392dc4c455f841cb"},{"bytes":89,"name":"manifest.sig","sha256":"cb9a72ea2f115ee2de8cfa7dff6c571c2a36729751303eeead82dfaa6aad06b3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b4f5d2e0067520460f7cd326a737aeeadca6329ac25fc1cde893b97f3cb9f1bd"}],"publication_id":"OT-2026-000089332"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089332
OpenTechnical

OT-2026-000089332

Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
7418d06de71c64eb1d89ae6f9c0586e51d6d67c59c1a7bb12dc2f43cc9f7327a

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089332, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089332.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089332" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089332" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089332 Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089332 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089332 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089332 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089332", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1102 }, "figures": [], "files": [ { "bytes": 18426, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bf61958dfbab36d5b723575a1cdb08712906dafcf849a9c81794ab65baa22f2b" }, { "bytes": 7999, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "601ac3ae7ef26b33aa8ce299ee00ef9a9d6b9e17fdc1ff465967d57d8444f95a" }, { "bytes": 7661, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7418d06de71c64eb1d89ae6f9c0586e51d6d67c59c1a7bb12dc2f43cc9f7327a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089332/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089332", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-797e-bc3f-204c95a0135d" } VQvi3DvZshvxjNDvAZPC6IgXkhPAduHYwAIBACfFeV4BfnKIM7EpDMu0jwINdDgrOcSLqFqmzhL9owESPh/bCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: VQvi3DvZshvxjNDvAZPC6IgXkhPAduHYwAIBACfFeV4BfnKIM7EpDMu0jwINdDgrOcSLqFqmzhL9owESPh/bCA== {"files":[{"bytes":19241,"name":"index.html","sha256":"6ec3d141ffedfe65fcba043c197a0ce3acadfeee235c1a0d12d64fc6960a99fa"},{"bytes":8700,"name":"publication.md","sha256":"1373ec90552877d53fd19d86408b1ed99173ddfd703e4c768bbd3480f22f35dd"},{"bytes":8356,"name":"publication.txt","sha256":"76d45f15a8be95c7e01a16051260745cced720baf2b277ffeb269b6c2d708d22"},{"bytes":2867,"name":"manifest.json","sha256":"b26e41c7df7c05e35f04fcf5e54d8b45d6401ba687ad073e86cf0e6df7e71953"},{"bytes":89,"name":"manifest.sig","sha256":"8a69c076f4485cfa968d1ef80a64c4dd23bfcccfd671113ee3df213d9b55398c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9ebe5f4e923dbbaf601e597b7b44c9a3426751c5385b7d02e3357aa61f025fb4"}],"publication_id":"OT-2026-000089333"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089333
OpenTechnical

OT-2026-000089333

Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
76d45f15a8be95c7e01a16051260745cced720baf2b277ffeb269b6c2d708d22

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089333, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089333.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089333" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089333" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089333 Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089333 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089333 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089333 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089333", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1208 }, "figures": [], "files": [ { "bytes": 19241, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6ec3d141ffedfe65fcba043c197a0ce3acadfeee235c1a0d12d64fc6960a99fa" }, { "bytes": 8700, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1373ec90552877d53fd19d86408b1ed99173ddfd703e4c768bbd3480f22f35dd" }, { "bytes": 8356, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "76d45f15a8be95c7e01a16051260745cced720baf2b277ffeb269b6c2d708d22" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089333/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089333", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-73d5-a7be-fc0ec58c97ce" } OtKO8r+TPbkDYabnCW+FTn+ToA93xTZB+p3XagGH10yECKfW0NzwpsPwQgw9pbRmhI12DMqbJ3GV1YLrShYwAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: OtKO8r+TPbkDYabnCW+FTn+ToA93xTZB+p3XagGH10yECKfW0NzwpsPwQgw9pbRmhI12DMqbJ3GV1YLrShYwAA== {"files":[{"bytes":18988,"name":"index.html","sha256":"9368d7a6c51d3d2fc28cf8b1483ec188151cec289f157377e77e13b0fae28127"},{"bytes":8490,"name":"publication.md","sha256":"e9c045638ed0b9bb37cd707aea421838d2c5207a1143163eed5160a3bed33398"},{"bytes":8146,"name":"publication.txt","sha256":"6b2f0f5a9a7f9cb6f19d905cdaa64dd38991d26000015e242b98475438804a31"},{"bytes":2867,"name":"manifest.json","sha256":"c1deebdc6c4f9235a574304d53eb9ac67014b05dfa9be0eaf52e6cc947ab3b0c"},{"bytes":89,"name":"manifest.sig","sha256":"f6f2adfbc9d83f1d75c246e0ca38160cb1adbad21ff2fd6e96742fca54229825"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a97defbdcb4551574f06a2f723dd202ebb023663959c7ec21e759e836eef1c23"}],"publication_id":"OT-2026-000089334"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089334
OpenTechnical

OT-2026-000089334

Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
6b2f0f5a9a7f9cb6f19d905cdaa64dd38991d26000015e242b98475438804a31

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089334, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089334.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089334" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089334" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089334 Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089334 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089334 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089334 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089334", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1173 }, "figures": [], "files": [ { "bytes": 18988, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9368d7a6c51d3d2fc28cf8b1483ec188151cec289f157377e77e13b0fae28127" }, { "bytes": 8490, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e9c045638ed0b9bb37cd707aea421838d2c5207a1143163eed5160a3bed33398" }, { "bytes": 8146, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "6b2f0f5a9a7f9cb6f19d905cdaa64dd38991d26000015e242b98475438804a31" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089334/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089334", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7b56-aacf-89303ef9dad2" } 7o7Sv1NNfp3Fr839sh412OG4skZZx2Lhv+b6TQZWbL6ca0M76Wu2hDBri4A3BjHoQmUkM1f/sdyrWFYHQOVfDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 7o7Sv1NNfp3Fr839sh412OG4skZZx2Lhv+b6TQZWbL6ca0M76Wu2hDBri4A3BjHoQmUkM1f/sdyrWFYHQOVfDg== {"files":[{"bytes":18427,"name":"index.html","sha256":"ef46db960fec8918960f3348411228678b4b01ade9ff0b6778e385ab2e1d682b"},{"bytes":8000,"name":"publication.md","sha256":"12ccdad8a5088c3134e08f606035737f9e9a4fb447b99c0b21f9ac13c6e3a6d1"},{"bytes":7662,"name":"publication.txt","sha256":"91e3ab8eb5c7ac4766f9d1414f975e4b53d10f842617d04edf6ca2e78e3a45bb"},{"bytes":2855,"name":"manifest.json","sha256":"879e8fde60b31b1e2f81fced8ae73c0bf9c9cc39f30874bb003fee73d35de937"},{"bytes":89,"name":"manifest.sig","sha256":"b97a3a33ef47d2666fbd91298e191a54a2ce1dbbfa1e093fa4389d1a0c500447"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8c9bdd084a4a45668226729a5f7e9a56563622795f8a09bf1f1d3d8bc03136c2"}],"publication_id":"OT-2026-000089335"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089335
OpenTechnical

OT-2026-000089335

Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
91e3ab8eb5c7ac4766f9d1414f975e4b53d10f842617d04edf6ca2e78e3a45bb

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089335, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089335.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089335" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089335" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089335 Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089335 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089335 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089335 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089335", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1102 }, "figures": [], "files": [ { "bytes": 18427, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ef46db960fec8918960f3348411228678b4b01ade9ff0b6778e385ab2e1d682b" }, { "bytes": 8000, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "12ccdad8a5088c3134e08f606035737f9e9a4fb447b99c0b21f9ac13c6e3a6d1" }, { "bytes": 7662, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "91e3ab8eb5c7ac4766f9d1414f975e4b53d10f842617d04edf6ca2e78e3a45bb" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089335/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089335", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7c28-8466-39df41db5956" } j5XWaTyEyHBF4fhILm/A107lYCCOjBEB1Rz950cUz5/+vLJrqJxzFg/ScKq/yGSrEuEn6A9uJD+Eo382+Ta5DA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: j5XWaTyEyHBF4fhILm/A107lYCCOjBEB1Rz950cUz5/+vLJrqJxzFg/ScKq/yGSrEuEn6A9uJD+Eo382+Ta5DA== {"files":[{"bytes":19242,"name":"index.html","sha256":"87f3e807fb1559e037be86f7485900d89c26cf137722e0c262ec6f23695e3320"},{"bytes":8701,"name":"publication.md","sha256":"a8ffb6b55ef7eb0d599fe7e51eaeee8a76ae743d8b7bb8cd2174db6aa6aae71b"},{"bytes":8357,"name":"publication.txt","sha256":"d51d6b4d1097462bf54c88d32bd054822c403d1a3bb0987e284dfea357c5f869"},{"bytes":2867,"name":"manifest.json","sha256":"7fad59d6123e751424e4c77dbec7a1215dcdbc485e7afb69bbc53260574060f9"},{"bytes":89,"name":"manifest.sig","sha256":"7b16081ec1af61d3400b68171aa2fcac27fc9a90f9caeddfe477ab6639bc7894"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8658f0ad33ce5f35c8750d44d41d21d0b7692a0df24c45f5a058acc7739b766f"}],"publication_id":"OT-2026-000089336"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089336
OpenTechnical

OT-2026-000089336

Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
d51d6b4d1097462bf54c88d32bd054822c403d1a3bb0987e284dfea357c5f869

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089336, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089336.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089336" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089336" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089336 Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089336 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089336 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089336 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089336", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1208 }, "figures": [], "files": [ { "bytes": 19242, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "87f3e807fb1559e037be86f7485900d89c26cf137722e0c262ec6f23695e3320" }, { "bytes": 8701, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a8ffb6b55ef7eb0d599fe7e51eaeee8a76ae743d8b7bb8cd2174db6aa6aae71b" }, { "bytes": 8357, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d51d6b4d1097462bf54c88d32bd054822c403d1a3bb0987e284dfea357c5f869" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089336/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089336", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7286-9971-77f97162e24e" } PAcRw00HoDI+yox9aXu2MlnehDGDfEfEaHRlScGj21fjhDdrezNLgOPZvffNhx7UkTM6r9xQlH0ni5B0ScCDDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: PAcRw00HoDI+yox9aXu2MlnehDGDfEfEaHRlScGj21fjhDdrezNLgOPZvffNhx7UkTM6r9xQlH0ni5B0ScCDDg== {"files":[{"bytes":18989,"name":"index.html","sha256":"f136bf513b71e7b413c4826f6bd7937b07d4498dad85708060adf99934adb067"},{"bytes":8491,"name":"publication.md","sha256":"7ceef5369632d90f25e31dc69e7b63e82023805e6db40c734122e027da6f64a4"},{"bytes":8147,"name":"publication.txt","sha256":"62d4806d063156beb4b2a8addd14b0a0f5ee27ea02e4ebf20a84c9e61e1b3fe4"},{"bytes":2867,"name":"manifest.json","sha256":"0a9af39219bed09f2eae85e1dc87465c7ae84f73b914f6560fcb730f19cb2d54"},{"bytes":89,"name":"manifest.sig","sha256":"c37cf8603af612109237501678ec14087573fa2936925dbdf009dac25d65b291"},{"bytes":227,"name":"manifest.sig.txt","sha256":"944b70a5bc356dff1e8dcc0b24f9deb1149aae94ec28f8773dfeec9cd8a32ca5"}],"publication_id":"OT-2026-000089337"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089337
OpenTechnical

OT-2026-000089337

Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
62d4806d063156beb4b2a8addd14b0a0f5ee27ea02e4ebf20a84c9e61e1b3fe4

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089337, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089337.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089337" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089337" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089337 Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089337 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089337 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089337 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089337", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1173 }, "figures": [], "files": [ { "bytes": 18989, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f136bf513b71e7b413c4826f6bd7937b07d4498dad85708060adf99934adb067" }, { "bytes": 8491, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7ceef5369632d90f25e31dc69e7b63e82023805e6db40c734122e027da6f64a4" }, { "bytes": 8147, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "62d4806d063156beb4b2a8addd14b0a0f5ee27ea02e4ebf20a84c9e61e1b3fe4" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089337/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089337", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7fbc-aa0b-84c41532469f" } uTQaC3hWey7CP3rzUyonvYmqTeG6sT3R6dOS19o+Ug+ZDgSr2EIjyS0gquLOTkHOH5r8xasHL5WUVmps38WcBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: uTQaC3hWey7CP3rzUyonvYmqTeG6sT3R6dOS19o+Ug+ZDgSr2EIjyS0gquLOTkHOH5r8xasHL5WUVmps38WcBQ== {"files":[{"bytes":18431,"name":"index.html","sha256":"12f72f7e22f74807fc382eb99620515654cac57610d7e2d421802aa65e68366e"},{"bytes":8004,"name":"publication.md","sha256":"1626c5d5c8306d83a7a09f2577358b8dc9e116fbf5f61677045b0cce1c5b6261"},{"bytes":7666,"name":"publication.txt","sha256":"dc6d816f363c5ff185718aafee94a5c6b5a8b4a0f29445ef5a4eac64a1981531"},{"bytes":2855,"name":"manifest.json","sha256":"9b97da4563d9be90769d2ad5b93ecd0f72f4bbb51c9590537a2f8ff0e3bbb71f"},{"bytes":89,"name":"manifest.sig","sha256":"6eb16677cc07425b3ef9b60510a46d6b74e95b6f8ee1cb43af5ff46e070f9bd2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8a58a3c4b40ab4a1684129749c88570d5202a3e1d5167d1c868c954d13da4eff"}],"publication_id":"OT-2026-000089338"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089338
OpenTechnical

OT-2026-000089338

Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
dc6d816f363c5ff185718aafee94a5c6b5a8b4a0f29445ef5a4eac64a1981531

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089338, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089338.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089338" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089338" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089338 Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089338 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089338 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089338 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089338", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1102 }, "figures": [], "files": [ { "bytes": 18431, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "12f72f7e22f74807fc382eb99620515654cac57610d7e2d421802aa65e68366e" }, { "bytes": 8004, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1626c5d5c8306d83a7a09f2577358b8dc9e116fbf5f61677045b0cce1c5b6261" }, { "bytes": 7666, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "dc6d816f363c5ff185718aafee94a5c6b5a8b4a0f29445ef5a4eac64a1981531" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089338/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089338", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-75a6-b6a3-3765c78c62a9" } Cv95lZy5izlMgl/cn6ml+JxCibJp8uMYJKC4Lo4WFctVgYUXdD/jrIMxmtiP6avJ2EoY5UJQHNVjO9MYtbt5Cg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Cv95lZy5izlMgl/cn6ml+JxCibJp8uMYJKC4Lo4WFctVgYUXdD/jrIMxmtiP6avJ2EoY5UJQHNVjO9MYtbt5Cg== {"files":[{"bytes":19246,"name":"index.html","sha256":"c45d688e50f9ee2390aecf89251505456cce1f0f4c879576fe7ebbf1c9b5b1a2"},{"bytes":8705,"name":"publication.md","sha256":"1b57e3258f8835e01b977b428cf4e10983c8e086b43c281fb29690a9c7a7ee09"},{"bytes":8361,"name":"publication.txt","sha256":"07d4b618f73a80481ae77a89139d54ca0b09e8aea925a7cc879a22e6960442e4"},{"bytes":2867,"name":"manifest.json","sha256":"639f90f31f0084f0eb8406eeb73f52219ba10183f3bff8b07cad5b40ab362158"},{"bytes":89,"name":"manifest.sig","sha256":"708fbfc970aaf5e6a2c57f0baf38d049750c1279a4b157617fc164ec7814b033"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c52f50f9132ea8fd435cdc7673bd1750a7faff0bb17fd8ccec43580f9760dfc4"}],"publication_id":"OT-2026-000089339"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089339
OpenTechnical

OT-2026-000089339

Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
07d4b618f73a80481ae77a89139d54ca0b09e8aea925a7cc879a22e6960442e4

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089339, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089339.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089339" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089339" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089339 Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089339 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089339 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089339 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089339", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1208 }, "figures": [], "files": [ { "bytes": 19246, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c45d688e50f9ee2390aecf89251505456cce1f0f4c879576fe7ebbf1c9b5b1a2" }, { "bytes": 8705, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1b57e3258f8835e01b977b428cf4e10983c8e086b43c281fb29690a9c7a7ee09" }, { "bytes": 8361, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "07d4b618f73a80481ae77a89139d54ca0b09e8aea925a7cc879a22e6960442e4" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089339/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089339", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7ae5-b8c3-d287cd335733" } uiGPoLaB9i2YV4Rc9LHJdZZwsnDj4x1joJYR8TkUNS5QDqiu0nLaKxZAK+6CJha+Ki5lJ1fd4cmZ9l1adNsXCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: uiGPoLaB9i2YV4Rc9LHJdZZwsnDj4x1joJYR8TkUNS5QDqiu0nLaKxZAK+6CJha+Ki5lJ1fd4cmZ9l1adNsXCQ== {"files":[{"bytes":18993,"name":"index.html","sha256":"1f8ee65a9714e00ba0609220cc52b84cbf0c9120640b07eb7ba81068f8b84013"},{"bytes":8495,"name":"publication.md","sha256":"af8dd848f8feca5a45c027d92a8ceb59bb29ac2191f5da1f5e0502c5a40626df"},{"bytes":8151,"name":"publication.txt","sha256":"a05dbf9cc078e11a0bea37d2f8dcc9c8c720bc2d97c571491a865d5c7f4b7fe9"},{"bytes":2867,"name":"manifest.json","sha256":"f794284c07cbe2008d7af24c4a13e7f69a5b57bbef611f46827ecdf339f2e628"},{"bytes":89,"name":"manifest.sig","sha256":"932809197746bb5d54d72f1b9657cc3c48396ba82897a728d0c96eab68c1be91"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e5bb14f091fc14ec36d726bb61b4ddfe0c46f03e99b8a18196d202d1405357e6"}],"publication_id":"OT-2026-000089340"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089340
OpenTechnical

OT-2026-000089340

Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a05dbf9cc078e11a0bea37d2f8dcc9c8c720bc2d97c571491a865d5c7f4b7fe9

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089340, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089340.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089340" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089340" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089340 Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089340 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089340 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089340 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089340", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1173 }, "figures": [], "files": [ { "bytes": 18993, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1f8ee65a9714e00ba0609220cc52b84cbf0c9120640b07eb7ba81068f8b84013" }, { "bytes": 8495, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "af8dd848f8feca5a45c027d92a8ceb59bb29ac2191f5da1f5e0502c5a40626df" }, { "bytes": 8151, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a05dbf9cc078e11a0bea37d2f8dcc9c8c720bc2d97c571491a865d5c7f4b7fe9" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089340/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089340", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-730a-815f-3f382a889eb4" } pYHY99gx+UJ41REM/lg8yNQCqz0xNXSMcnXMSYci0Zb3ANPW1H9xutqwalx4BKfGxd9FJuLGG8QRUP8NV0dyBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: pYHY99gx+UJ41REM/lg8yNQCqz0xNXSMcnXMSYci0Zb3ANPW1H9xutqwalx4BKfGxd9FJuLGG8QRUP8NV0dyBA== {"files":[{"bytes":18620,"name":"index.html","sha256":"8022675750dbabad17f37234aa7e3f3d82a19b3263cc8c2564de9112fd6a5524"},{"bytes":8161,"name":"publication.md","sha256":"793c245a1312db174fc1866a22c6ac9d62d8bed294fb1f90f215c2c38a25657f"},{"bytes":7833,"name":"publication.txt","sha256":"ea90789801fa00a81628a9d237453013f6082deaf2780083fafdf91935767cc4"},{"bytes":2834,"name":"manifest.json","sha256":"de116a8954594fd7b5f5fadab5d7df0775aadaf1ed95976e65d5ee37fac787b5"},{"bytes":89,"name":"manifest.sig","sha256":"39c825600a0fc409fcc7b1d8747c1fbf61912bfdea351c2c0e1e556ca51510e5"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a4fbd626b4eaf9631c004d0007ab5bd2b1cad55373e43b0b154505ee419932c8"}],"publication_id":"OT-2026-000089341"} Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089341
OpenTechnical

OT-2026-000089341

Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
ea90789801fa00a81628a9d237453013f6082deaf2780083fafdf91935767cc4

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089341, “Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089341.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089341" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089341" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089341 Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089341 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089341 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089341 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089341", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1142 }, "figures": [], "files": [ { "bytes": 18620, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8022675750dbabad17f37234aa7e3f3d82a19b3263cc8c2564de9112fd6a5524" }, { "bytes": 8161, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "793c245a1312db174fc1866a22c6ac9d62d8bed294fb1f90f215c2c38a25657f" }, { "bytes": 7833, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ea90789801fa00a81628a9d237453013f6082deaf2780083fafdf91935767cc4" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089341/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089341", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-76ab-bbd0-3432e3e5915e" } 20cC0t7kZaxkckrqL3RZDPaTAajCtsuJ6uVrWVNG22LoFNVvGYHaaUDZMVpJ2nKMykrSy07q+sDIYxZF9UPNBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 20cC0t7kZaxkckrqL3RZDPaTAajCtsuJ6uVrWVNG22LoFNVvGYHaaUDZMVpJ2nKMykrSy07q+sDIYxZF9UPNBA== {"files":[{"bytes":19435,"name":"index.html","sha256":"3d881391d6d70ee2aa45bf38b0edc304570de65511a807447ae9eb1d43256697"},{"bytes":8862,"name":"publication.md","sha256":"ebaefeb508f3361b6eac19d52ecc1e051dab4db27fa6c9afe83f2c0dafba4edc"},{"bytes":8528,"name":"publication.txt","sha256":"e17e50cffbafa32ac80009b1577b686aa5fe990a60d4a4c47f2372a8ba8831a7"},{"bytes":2846,"name":"manifest.json","sha256":"f6b9643f9a4fed666e85e008a26c96d95f73977642e1f8375666b2b1069b1baf"},{"bytes":89,"name":"manifest.sig","sha256":"a0ba70fa859ed76ccd89c1a6b0bfec305b93d01904f5c26d64e3854ffae9357e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ab524b282a90086cdd7f45e403b74a5beb726157fec8e89b47fdcb4f5721e15d"}],"publication_id":"OT-2026-000089342"} Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089342
OpenTechnical

OT-2026-000089342

Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e17e50cffbafa32ac80009b1577b686aa5fe990a60d4a4c47f2372a8ba8831a7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089342, “Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089342.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089342" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089342" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089342 Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089342 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089342 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089342 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089342", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1248 }, "figures": [], "files": [ { "bytes": 19435, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3d881391d6d70ee2aa45bf38b0edc304570de65511a807447ae9eb1d43256697" }, { "bytes": 8862, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ebaefeb508f3361b6eac19d52ecc1e051dab4db27fa6c9afe83f2c0dafba4edc" }, { "bytes": 8528, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e17e50cffbafa32ac80009b1577b686aa5fe990a60d4a4c47f2372a8ba8831a7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089342/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089342", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-75c1-8185-a1d56ee8965d" } yXCZhce8rmLDqACRU8Nor0Fim6tfaBM/z6PefUkwa1/RijRBbREom7XuNDoh45TyNuF1HoyjDpH2PWpIGILLCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: yXCZhce8rmLDqACRU8Nor0Fim6tfaBM/z6PefUkwa1/RijRBbREom7XuNDoh45TyNuF1HoyjDpH2PWpIGILLCg== {"files":[{"bytes":19182,"name":"index.html","sha256":"8a3ab799f4318dd7e903be88064a2742049116ca84e928ba2e6a45d8c77303c2"},{"bytes":8652,"name":"publication.md","sha256":"b38fee0eb5dc6bb9767499051529c3414b5ccd8d89888f4732186363c571532c"},{"bytes":8318,"name":"publication.txt","sha256":"047e9269806ee91b665ff8e44a65f0629c942958ed01bd674fee48ee0d5910f8"},{"bytes":2846,"name":"manifest.json","sha256":"9992f16070fd70938561582ab1822b4323194ad030c8475eb1221917782f4d0e"},{"bytes":89,"name":"manifest.sig","sha256":"d5a47e12b3d3cbd1c9cf0a880e797bead2a31375f715b16f0d81866ab90eda91"},{"bytes":227,"name":"manifest.sig.txt","sha256":"751f0d5517dcbf4350d33d0ff44428a3b7e5928cec7eb93b08f256431b6e07ea"}],"publication_id":"OT-2026-000089343"} Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089343
OpenTechnical

OT-2026-000089343

Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
047e9269806ee91b665ff8e44a65f0629c942958ed01bd674fee48ee0d5910f8

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089343, “Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089343.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089343" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089343" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089343 Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089343 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089343 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089343 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089343", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1213 }, "figures": [], "files": [ { "bytes": 19182, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8a3ab799f4318dd7e903be88064a2742049116ca84e928ba2e6a45d8c77303c2" }, { "bytes": 8652, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b38fee0eb5dc6bb9767499051529c3414b5ccd8d89888f4732186363c571532c" }, { "bytes": 8318, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "047e9269806ee91b665ff8e44a65f0629c942958ed01bd674fee48ee0d5910f8" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089343/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089343", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-705a-a5d5-ab38dbb3857f" } RPdt2Q45pwx8qffacai++1u58o0z2tBNziozBuO65KP3se3ReM8zQRVHzQvQhJC6Fmx8eNuO1GfAx8QRixoPBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: RPdt2Q45pwx8qffacai++1u58o0z2tBNziozBuO65KP3se3ReM8zQRVHzQvQhJC6Fmx8eNuO1GfAx8QRixoPBw== {"files":[{"bytes":18566,"name":"index.html","sha256":"c97c602dbb8c34e4a3741b0515cf6519cfbb138a59c009006e1d3f1912cb67c1"},{"bytes":8107,"name":"publication.md","sha256":"c4598447a1b8054e0b9a63d9c5fc601607f0ac360b0c0288c31d73f0b7db8851"},{"bytes":7779,"name":"publication.txt","sha256":"06655ed8a72009c50e0123a11dd70238490d6ff48b18a36e088f9898bd718d36"},{"bytes":2834,"name":"manifest.json","sha256":"4173b8ad0ad7b09db0ea66a1df330630c640308e1cf9e5311da82068cf693584"},{"bytes":89,"name":"manifest.sig","sha256":"e3ef305bd950e35f17b0477f30e6e868e6eb268a705164d7f3bd1087814f8ce5"},{"bytes":227,"name":"manifest.sig.txt","sha256":"be3886c862b874832aa71b8bd4be4b5c014355ab1708c8565f1788229a685d32"}],"publication_id":"OT-2026-000089344"} Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089344
OpenTechnical

OT-2026-000089344

Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
06655ed8a72009c50e0123a11dd70238490d6ff48b18a36e088f9898bd718d36

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089344, “Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089344.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089344" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089344" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089344 Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089344 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089344 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089344 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089344", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1127 }, "figures": [], "files": [ { "bytes": 18566, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c97c602dbb8c34e4a3741b0515cf6519cfbb138a59c009006e1d3f1912cb67c1" }, { "bytes": 8107, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c4598447a1b8054e0b9a63d9c5fc601607f0ac360b0c0288c31d73f0b7db8851" }, { "bytes": 7779, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "06655ed8a72009c50e0123a11dd70238490d6ff48b18a36e088f9898bd718d36" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089344/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089344", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7941-9d64-4f9217464462" } bTLWdOEu6O+OuFsZErYdBCcWhiOM1/nFdRu9Pv2Bf1HZILIdJFU3LgzDLE2oNicP8bJgV8f0a3ny7rilniRDBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: bTLWdOEu6O+OuFsZErYdBCcWhiOM1/nFdRu9Pv2Bf1HZILIdJFU3LgzDLE2oNicP8bJgV8f0a3ny7rilniRDBg== {"files":[{"bytes":19381,"name":"index.html","sha256":"641d348ee3a65398546ddca23d4154a0e2771b6eb4c5835146137548dc31b85a"},{"bytes":8808,"name":"publication.md","sha256":"b1cca6b27fb16d6c8e970760029db6fd8af773087d4f4c8fd896390cebc64e02"},{"bytes":8474,"name":"publication.txt","sha256":"d3d8693ea8ce008ed06a5c5e433360d065eae5dd6b4f22604014d29d13de418f"},{"bytes":2846,"name":"manifest.json","sha256":"f1a008e9f331b2c960a8ed4058af4592d42fcd882600d66284b695da692c2361"},{"bytes":89,"name":"manifest.sig","sha256":"d690f597368141019e08b9936acc49fed2c4ba07b8ec15ad0d722ff72356321f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"32ef2cb9fc9eb3c7d701a99ca6c497c8509c09b9561d7ce373966fb7a25665fa"}],"publication_id":"OT-2026-000089345"} Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089345
OpenTechnical

OT-2026-000089345

Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
d3d8693ea8ce008ed06a5c5e433360d065eae5dd6b4f22604014d29d13de418f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089345, “Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089345.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089345" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089345" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089345 Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089345 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089345 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089345 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089345", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1233 }, "figures": [], "files": [ { "bytes": 19381, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "641d348ee3a65398546ddca23d4154a0e2771b6eb4c5835146137548dc31b85a" }, { "bytes": 8808, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b1cca6b27fb16d6c8e970760029db6fd8af773087d4f4c8fd896390cebc64e02" }, { "bytes": 8474, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d3d8693ea8ce008ed06a5c5e433360d065eae5dd6b4f22604014d29d13de418f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089345/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089345", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7c84-ac12-a4dd8902d571" } lgKHQwd17ZejKnMicS54d+xFEhPz0cZcdvy3VxxKdyvWhMXWIKTxr2vWqrP44WtEgGa4SL5W4QrMu68q+CZtAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: lgKHQwd17ZejKnMicS54d+xFEhPz0cZcdvy3VxxKdyvWhMXWIKTxr2vWqrP44WtEgGa4SL5W4QrMu68q+CZtAw== {"files":[{"bytes":19128,"name":"index.html","sha256":"a20caae6b97eb76508e3395dca8154ae578a8ddc811964407f4b9c4ba8affb7b"},{"bytes":8598,"name":"publication.md","sha256":"b0899889c6d07dfce61c3ae9fb74942657dd9bcd069b9c788dbd679d581b4634"},{"bytes":8264,"name":"publication.txt","sha256":"8941e6f0d56d43e36327c8ac7da1fba0f3eb237dd1063eb0dbae709f61377a67"},{"bytes":2846,"name":"manifest.json","sha256":"af357a0de369cce2ed30d9528281ff9b7e46471e0a7339f104e6f3a2a070e4c2"},{"bytes":89,"name":"manifest.sig","sha256":"0ad04f71d38a3173ac5dcdc0cfb78d937960845820b54c4d0ce4441ca276fc32"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1cefe6b58ce4908322926f968a942604df40beac1e9b3e570c0e8d81afa6c629"}],"publication_id":"OT-2026-000089346"} Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089346
OpenTechnical

OT-2026-000089346

Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8941e6f0d56d43e36327c8ac7da1fba0f3eb237dd1063eb0dbae709f61377a67

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089346, “Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089346.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089346" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089346" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089346 Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089346 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089346 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089346 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089346", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1198 }, "figures": [], "files": [ { "bytes": 19128, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a20caae6b97eb76508e3395dca8154ae578a8ddc811964407f4b9c4ba8affb7b" }, { "bytes": 8598, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b0899889c6d07dfce61c3ae9fb74942657dd9bcd069b9c788dbd679d581b4634" }, { "bytes": 8264, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8941e6f0d56d43e36327c8ac7da1fba0f3eb237dd1063eb0dbae709f61377a67" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089346/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089346", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7db2-9463-d0a2838a9604" } axOz27+IyLgmFmWopm82K1oZXIfGcQK34Xq+aZuGuq5l9i3Uz2l0MozO8ng2wOb1pr17nIc7gqexUjUijca3Dw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: axOz27+IyLgmFmWopm82K1oZXIfGcQK34Xq+aZuGuq5l9i3Uz2l0MozO8ng2wOb1pr17nIc7gqexUjUijca3Dw== {"files":[{"bytes":18320,"name":"index.html","sha256":"aa09f6fa23d21a580533f51f5206bc9e017383a4eeff275379e453e597e0b021"},{"bytes":7909,"name":"publication.md","sha256":"74c3d378d4e32424d28a26e8927972662eecd9edde605621d522a759322e2b2e"},{"bytes":7579,"name":"publication.txt","sha256":"a72c4307f2adce75b3d68be151a3dc4dd59a0d4bc80fdcc6955a6c0c8033f07f"},{"bytes":2847,"name":"manifest.json","sha256":"5e57b5e436f81e96385dd8097f97ec0a5199820484e5fe3e470306265a130283"},{"bytes":89,"name":"manifest.sig","sha256":"004ab6ac3ae8c5edbbdc188a656c035eac1aabbbc87de82f3a5cf4f4afaa5823"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e8128875a11704d858ce94019f7811b7da53ac5b12e813ece5b836326a5e4a55"}],"publication_id":"OT-2026-000089347"} Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089347
OpenTechnical

OT-2026-000089347

Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
a72c4307f2adce75b3d68be151a3dc4dd59a0d4bc80fdcc6955a6c0c8033f07f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089347, “Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089347.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089347" title: "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089347" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089347 Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089347 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089347 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089347 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089347", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1090 }, "figures": [], "files": [ { "bytes": 18320, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "aa09f6fa23d21a580533f51f5206bc9e017383a4eeff275379e453e597e0b021" }, { "bytes": 7909, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "74c3d378d4e32424d28a26e8927972662eecd9edde605621d522a759322e2b2e" }, { "bytes": 7579, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a72c4307f2adce75b3d68be151a3dc4dd59a0d4bc80fdcc6955a6c0c8033f07f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089347/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089347", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7291-8936-f5421b0c0e93" } /twd182nl0X8oDgrLvFIM8okxEjh3SnvRsvopff9q+6L8+hnb5gC1KBJzZ7EpEFrn2dIAYf/bjtC0kJZcxlpAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: /twd182nl0X8oDgrLvFIM8okxEjh3SnvRsvopff9q+6L8+hnb5gC1KBJzZ7EpEFrn2dIAYf/bjtC0kJZcxlpAg== {"files":[{"bytes":19135,"name":"index.html","sha256":"bda7b424cb38dd040735086498a58b335486dfb890cb92bfda9165e5f4edb2c8"},{"bytes":8610,"name":"publication.md","sha256":"5764436d3b5c3df5333beaf3dbb60ceb4b7432807725a7a0a33615ac11d025bb"},{"bytes":8274,"name":"publication.txt","sha256":"cf346b9b6f698a4764e4aece31df786ee22963fe3b21966eac21581167d59edf"},{"bytes":2859,"name":"manifest.json","sha256":"8385e5173dc53c6fcfec57674cf3ef34886589f669124f7af6885b3adb23a96e"},{"bytes":89,"name":"manifest.sig","sha256":"3f164389d0bb8d47f8b70b637656fbae7d17fad2d5e97654a1bcdb4afff81a13"},{"bytes":227,"name":"manifest.sig.txt","sha256":"cf173e03c87b1deef43ce85cd13a9fd18189c671bc6f7d5d981c6a2c512e4a3e"}],"publication_id":"OT-2026-000089348"} Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089348
OpenTechnical

OT-2026-000089348

Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cf346b9b6f698a4764e4aece31df786ee22963fe3b21966eac21581167d59edf

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089348, “Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089348.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089348" title: "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089348" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089348 Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089348 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089348 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089348 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089348", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1196 }, "figures": [], "files": [ { "bytes": 19135, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bda7b424cb38dd040735086498a58b335486dfb890cb92bfda9165e5f4edb2c8" }, { "bytes": 8610, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5764436d3b5c3df5333beaf3dbb60ceb4b7432807725a7a0a33615ac11d025bb" }, { "bytes": 8274, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cf346b9b6f698a4764e4aece31df786ee22963fe3b21966eac21581167d59edf" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089348/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089348", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7638-826e-273fb31e16b8" } QObnMqYYIezE2qGNfYcKsX3wsu1s7jh5ddmmm3pvQRgxvnGmIkWKIqItZj38FCdEyqpjUanuPIY98kpIxpVfBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: QObnMqYYIezE2qGNfYcKsX3wsu1s7jh5ddmmm3pvQRgxvnGmIkWKIqItZj38FCdEyqpjUanuPIY98kpIxpVfBQ== {"files":[{"bytes":18882,"name":"index.html","sha256":"6e3cadee0bd888545e0eaa05d7662b55541ff9ba5cbcb69e6305d7ebdcfce464"},{"bytes":8400,"name":"publication.md","sha256":"6ce6061293c00276be87179c6537b53d812521135335c7a909f32e9ac1ef3716"},{"bytes":8064,"name":"publication.txt","sha256":"ef4d017acfff2240c58b6997bae9e31f0309bc64e48f41513397e79d0e5e5f9c"},{"bytes":2859,"name":"manifest.json","sha256":"43cc7a1606de7b10d0f2d177713441181302fbb114daa5471dcd5bf72d8c35d5"},{"bytes":89,"name":"manifest.sig","sha256":"69162ec56c2d4c0a4991eb25b0e603709b0da0312e16fb97826c9f1bca8ed24b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4b33dc6a6c380d68489eba4027afbcbbca217abcd34ed11ecfccb9ae38ce9e11"}],"publication_id":"OT-2026-000089349"} Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089349
OpenTechnical

OT-2026-000089349

Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
ef4d017acfff2240c58b6997bae9e31f0309bc64e48f41513397e79d0e5e5f9c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089349, “Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089349.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089349" title: "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089349" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089349 Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089349 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089349 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089349 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089349", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1161 }, "figures": [], "files": [ { "bytes": 18882, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6e3cadee0bd888545e0eaa05d7662b55541ff9ba5cbcb69e6305d7ebdcfce464" }, { "bytes": 8400, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "6ce6061293c00276be87179c6537b53d812521135335c7a909f32e9ac1ef3716" }, { "bytes": 8064, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ef4d017acfff2240c58b6997bae9e31f0309bc64e48f41513397e79d0e5e5f9c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089349/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089349", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7d79-bbe9-fa94afad061d" } E4SVp8F6oSLqVFuNn0WzFdZ5TVZSyRT0XwCYA2CFZm1a7/wi+qmlC+PTaQZuNFxgcJEYUTozOTCylCk2lGSBAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: E4SVp8F6oSLqVFuNn0WzFdZ5TVZSyRT0XwCYA2CFZm1a7/wi+qmlC+PTaQZuNFxgcJEYUTozOTCylCk2lGSBAw== {"files":[{"bytes":18320,"name":"index.html","sha256":"655037dbd890a05a48df7638e35a9b68e77efa24eb4b3bb2dbb3761f1b5cdff1"},{"bytes":7909,"name":"publication.md","sha256":"729bb0265537f1c3714eac3c9bb7d58f368dbe4319372ff333f585501daf6825"},{"bytes":7579,"name":"publication.txt","sha256":"ef8711e5b45c6fc46300da4712c7a5e49b4efd63d64535c723c6f5100d943f3f"},{"bytes":2847,"name":"manifest.json","sha256":"0c01dd3f8fe0419097c3079ddff0e034389414b4aff77d37c0078ef3405610dc"},{"bytes":89,"name":"manifest.sig","sha256":"878cdbf8093ecb16511c1385e067525afd3ad6f2a7920ac24b7308eb7e02ea1a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9bc3a22fbe2e2d48a502a040b62616f0a2da976f9a02b953f7d97642c755d313"}],"publication_id":"OT-2026-000089350"} Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089350
OpenTechnical

OT-2026-000089350

Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
ef8711e5b45c6fc46300da4712c7a5e49b4efd63d64535c723c6f5100d943f3f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089350, “Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089350.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089350" title: "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089350" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089350 Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089350 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089350 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089350 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089350", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1090 }, "figures": [], "files": [ { "bytes": 18320, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "655037dbd890a05a48df7638e35a9b68e77efa24eb4b3bb2dbb3761f1b5cdff1" }, { "bytes": 7909, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "729bb0265537f1c3714eac3c9bb7d58f368dbe4319372ff333f585501daf6825" }, { "bytes": 7579, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ef8711e5b45c6fc46300da4712c7a5e49b4efd63d64535c723c6f5100d943f3f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089350/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089350", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7f6b-9040-678d2af756c1" } Y5rVz00u08+tIrmm3KlhBtSQVygsjRKS5JWJKN86d5tvXyxVbSXe56NxawyCxUSJEVAGGgRFX30yN8rtWIP5DQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Y5rVz00u08+tIrmm3KlhBtSQVygsjRKS5JWJKN86d5tvXyxVbSXe56NxawyCxUSJEVAGGgRFX30yN8rtWIP5DQ== {"files":[{"bytes":19135,"name":"index.html","sha256":"23e8f6581596edd8021a36e1006a214598f9aefe1bcf527a59cc3e9726e2380d"},{"bytes":8610,"name":"publication.md","sha256":"27654e900ca19173791110def58f20c075f779165b7e54bc246a7d17f1e07ac5"},{"bytes":8274,"name":"publication.txt","sha256":"4abe0d37b1bb781ccfc00259f8c09058000381007f67e4c5a398b39de02736e6"},{"bytes":2859,"name":"manifest.json","sha256":"eee5eea67f2d386e3f3bc5ac49cb6bcfbd978b756c73765f6f61e324977a3c5d"},{"bytes":89,"name":"manifest.sig","sha256":"961ea0a53cd5891591bffd7ae7f3fae29e76d9b2a2db91eaac76835cf1cf68a3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b6a6a45d97bedff5df79d927655b7f9796677dfcf0a2d34b46ef2a6f82d00b0d"}],"publication_id":"OT-2026-000089351"} Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089351
OpenTechnical

OT-2026-000089351

Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
4abe0d37b1bb781ccfc00259f8c09058000381007f67e4c5a398b39de02736e6

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089351, “Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089351.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089351" title: "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089351" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089351 Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089351 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089351 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089351 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089351", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1196 }, "figures": [], "files": [ { "bytes": 19135, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "23e8f6581596edd8021a36e1006a214598f9aefe1bcf527a59cc3e9726e2380d" }, { "bytes": 8610, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "27654e900ca19173791110def58f20c075f779165b7e54bc246a7d17f1e07ac5" }, { "bytes": 8274, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4abe0d37b1bb781ccfc00259f8c09058000381007f67e4c5a398b39de02736e6" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089351/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089351", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7d7d-9d54-3886fb685794" } bNHiaTy47YyrVNck4vfUyhI63eRbLry88fjqUpQ5E5/31NyGukxVIy9+O1isIexNpyRyFzCb7KiRESDHdR1KAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: bNHiaTy47YyrVNck4vfUyhI63eRbLry88fjqUpQ5E5/31NyGukxVIy9+O1isIexNpyRyFzCb7KiRESDHdR1KAg== {"files":[{"bytes":18882,"name":"index.html","sha256":"f7c9816bade90c9fa9ed08dd5ef2823c20407d51d0637c8d024af34d6f77f5db"},{"bytes":8400,"name":"publication.md","sha256":"fe44b404ff8f2da33fe281525da38976ec43c10553f9c3ea5020acbf2c2d6ed7"},{"bytes":8064,"name":"publication.txt","sha256":"4b58038492e8d021c1ccd32bc1291d683d35f3bea140653dd9fa3b496cb03c3f"},{"bytes":2859,"name":"manifest.json","sha256":"7b3a3d572423fc4759ba6894c4f31deecfc86dc881970061724ba3a8e67984c3"},{"bytes":89,"name":"manifest.sig","sha256":"724283a86a3fb2d189b8915effe54628c93b4aa0c66ee6d13918b2dea099d1c1"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7f2f2387d8e1416dba6437100e457c50f068dce90e4bead77476bf708f3c5496"}],"publication_id":"OT-2026-000089352"} Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089352
OpenTechnical

OT-2026-000089352

Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
4b58038492e8d021c1ccd32bc1291d683d35f3bea140653dd9fa3b496cb03c3f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089352, “Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089352.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089352" title: "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089352" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089352 Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089352 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089352 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089352 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089352", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1161 }, "figures": [], "files": [ { "bytes": 18882, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f7c9816bade90c9fa9ed08dd5ef2823c20407d51d0637c8d024af34d6f77f5db" }, { "bytes": 8400, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fe44b404ff8f2da33fe281525da38976ec43c10553f9c3ea5020acbf2c2d6ed7" }, { "bytes": 8064, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4b58038492e8d021c1ccd32bc1291d683d35f3bea140653dd9fa3b496cb03c3f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089352/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089352", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-71f1-8025-e20db4877a2e" } pg2kLQ/l6USU86ipCMEImQ180yyMPbRFz4f7AJB8MbBRrPBvtGPOrBJzbkGOis3expTudKqKx/n9D2uUHxx4Bg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: pg2kLQ/l6USU86ipCMEImQ180yyMPbRFz4f7AJB8MbBRrPBvtGPOrBJzbkGOis3expTudKqKx/n9D2uUHxx4Bg== {"files":[{"bytes":18415,"name":"index.html","sha256":"f140dc0a5110ea887d09a589234cbca6d636d3c9d7a7a09ded27a391da9a018f"},{"bytes":7994,"name":"publication.md","sha256":"a315011fbed33711bb201c83e4c13452ab8077c98761c355de2b26ee919efdc9"},{"bytes":7659,"name":"publication.txt","sha256":"e62429efd19fd68f552f1a186f24ebd7d9eac010cbc484c86b80e6328585cd19"},{"bytes":2852,"name":"manifest.json","sha256":"8e80ea8f7c6b1ebccba0e051921c7655204f0865d260cdd7a7ef9b485ec65814"},{"bytes":89,"name":"manifest.sig","sha256":"3d89a616d5e0912354a56bfa5f9b70df88f95b3f32987acadd18e07b20117f41"},{"bytes":227,"name":"manifest.sig.txt","sha256":"895e8ba4d02f571b3ba48431e33f6b229d39d1cd924a4c408db81bcbeb6f3946"}],"publication_id":"OT-2026-000089353"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089353
OpenTechnical

OT-2026-000089353

Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
e62429efd19fd68f552f1a186f24ebd7d9eac010cbc484c86b80e6328585cd19

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089353, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089353.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089353" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089353" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089353 Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089353 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089353 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089353 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089353", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1102 }, "figures": [], "files": [ { "bytes": 18415, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f140dc0a5110ea887d09a589234cbca6d636d3c9d7a7a09ded27a391da9a018f" }, { "bytes": 7994, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a315011fbed33711bb201c83e4c13452ab8077c98761c355de2b26ee919efdc9" }, { "bytes": 7659, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e62429efd19fd68f552f1a186f24ebd7d9eac010cbc484c86b80e6328585cd19" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089353/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089353", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7368-85f6-8d112bbedcb9" } YK+3m2kJaPmwNF70R3/5WBsqRX/1Rg0DaFleWUsdoAz4FLQlKzfiFaRnfv2MoO4lU6esAX1M3kLFjuJumsfWAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: YK+3m2kJaPmwNF70R3/5WBsqRX/1Rg0DaFleWUsdoAz4FLQlKzfiFaRnfv2MoO4lU6esAX1M3kLFjuJumsfWAg== {"files":[{"bytes":19230,"name":"index.html","sha256":"48a42f18deb39b14c5a4ce7023e7692817fab6ea15c648a5bf6b6de491e74cf1"},{"bytes":8695,"name":"publication.md","sha256":"df15190c49cede277c6888add65f9273018c090a23eb2938a7608e2b6317f5ef"},{"bytes":8354,"name":"publication.txt","sha256":"9ea4992139c023cdf373fa8868146006e3f13db991a4ad3adef93b91e6a52a02"},{"bytes":2864,"name":"manifest.json","sha256":"ee0ff44818a4cd9bf2f706d9eaecf39c7d9da483aa6f09449de4ff1f42bea450"},{"bytes":89,"name":"manifest.sig","sha256":"a00e059f7d2b6f522f94ab92727cec75d5f9fab80164aea95a437a8f3955a802"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f1b11b8853728e4ce3d6c322232feb551eed63779e61fe63055108f0ddfe5330"}],"publication_id":"OT-2026-000089354"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089354
OpenTechnical

OT-2026-000089354

Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
9ea4992139c023cdf373fa8868146006e3f13db991a4ad3adef93b91e6a52a02

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089354, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089354.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089354" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089354" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089354 Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089354 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089354 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089354 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089354", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1208 }, "figures": [], "files": [ { "bytes": 19230, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "48a42f18deb39b14c5a4ce7023e7692817fab6ea15c648a5bf6b6de491e74cf1" }, { "bytes": 8695, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "df15190c49cede277c6888add65f9273018c090a23eb2938a7608e2b6317f5ef" }, { "bytes": 8354, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9ea4992139c023cdf373fa8868146006e3f13db991a4ad3adef93b91e6a52a02" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089354/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089354", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7929-a714-4bcdc0392949" } SjZpInOk5KmOgG22Fq+Myt/cPkI6mSGjBhlRxQL7dI6XB47gDQBlvycPeMK8cDnRzdqPvuKZT7wGpI9ks4MMBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: SjZpInOk5KmOgG22Fq+Myt/cPkI6mSGjBhlRxQL7dI6XB47gDQBlvycPeMK8cDnRzdqPvuKZT7wGpI9ks4MMBQ== {"files":[{"bytes":18977,"name":"index.html","sha256":"592d70fd50bea06021c6c53607ced4ac39f981be23d0ac5406db3c04ce353202"},{"bytes":8485,"name":"publication.md","sha256":"e5e6840786ad364199b00653e61e32d4b64eb442dcbcf621b0a862640c34f6c4"},{"bytes":8144,"name":"publication.txt","sha256":"0d075be31996c75d3b00d9f1143c02aa6ce5105f7df5693c941227d38566b21e"},{"bytes":2864,"name":"manifest.json","sha256":"7968bd26778e1b701a061fff341be38fca5284d6f91169794f4d19ffacfa7244"},{"bytes":89,"name":"manifest.sig","sha256":"014807a8bcec502f021bffadfb211f4a44c70248473ba4a12b78be3d3bdcdc17"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3f968150db2e5d18bf3db31ed6ca717436c5046430c9718fe224ad67a8162a43"}],"publication_id":"OT-2026-000089355"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089355
OpenTechnical

OT-2026-000089355

Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
0d075be31996c75d3b00d9f1143c02aa6ce5105f7df5693c941227d38566b21e

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089355, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089355.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089355" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089355" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089355 Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089355 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089355 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089355 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089355", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1173 }, "figures": [], "files": [ { "bytes": 18977, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "592d70fd50bea06021c6c53607ced4ac39f981be23d0ac5406db3c04ce353202" }, { "bytes": 8485, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e5e6840786ad364199b00653e61e32d4b64eb442dcbcf621b0a862640c34f6c4" }, { "bytes": 8144, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0d075be31996c75d3b00d9f1143c02aa6ce5105f7df5693c941227d38566b21e" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089355/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089355", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7baf-b5c7-25ac636b6bdd" } tM2yJWi7Z9iyEWrjh7wePK0uV2XkHV7DRjNewwdgFa42arsvesXWOv9Bkyt5rzN7gUabhRFTm/y4rzfA1CkxBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: tM2yJWi7Z9iyEWrjh7wePK0uV2XkHV7DRjNewwdgFa42arsvesXWOv9Bkyt5rzN7gUabhRFTm/y4rzfA1CkxBw== {"files":[{"bytes":18416,"name":"index.html","sha256":"d2d85f3f392c42d18bad4b06e431ed3794862a6fe82c16827effe6a9961d8f37"},{"bytes":7995,"name":"publication.md","sha256":"2f002e4b9972cd9d189752f1e2ca57735823d00ac70503ba9241b6a7cafbc17c"},{"bytes":7660,"name":"publication.txt","sha256":"15c9870ff3f92b2c297f3c0f9c4d58c46cfe0e2ef83ed1e4743dc2c1dd139741"},{"bytes":2852,"name":"manifest.json","sha256":"ac0d8c2172419d644cab145d3c5a44b564f8e11aeba99886defac3ab96d140bf"},{"bytes":89,"name":"manifest.sig","sha256":"282ad01789ff4664cad131704838e29004d9198381cdb8f752b2cf39220af680"},{"bytes":227,"name":"manifest.sig.txt","sha256":"af5f0bed8ef61f99781d729beff62eed9162392db8c8a3bc39aa2f1df7399a6f"}],"publication_id":"OT-2026-000089356"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089356
OpenTechnical

OT-2026-000089356

Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
15c9870ff3f92b2c297f3c0f9c4d58c46cfe0e2ef83ed1e4743dc2c1dd139741

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089356, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089356.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089356" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089356" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089356 Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089356 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089356 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089356 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089356", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1102 }, "figures": [], "files": [ { "bytes": 18416, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d2d85f3f392c42d18bad4b06e431ed3794862a6fe82c16827effe6a9961d8f37" }, { "bytes": 7995, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "2f002e4b9972cd9d189752f1e2ca57735823d00ac70503ba9241b6a7cafbc17c" }, { "bytes": 7660, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "15c9870ff3f92b2c297f3c0f9c4d58c46cfe0e2ef83ed1e4743dc2c1dd139741" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089356/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089356", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7499-aa27-4ba96cf96cfe" } I1Lg3SBul7tRPJsCe8CLVLZ+aRQHR3BS1sR/na8tqvdK1kqWAFbsDcXG7nlDQRYGjKNF5rYftRpeNES/zQcLDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: I1Lg3SBul7tRPJsCe8CLVLZ+aRQHR3BS1sR/na8tqvdK1kqWAFbsDcXG7nlDQRYGjKNF5rYftRpeNES/zQcLDw== {"files":[{"bytes":19231,"name":"index.html","sha256":"d17b97d42dc728c239c9a9cb0cfe91209816cc97f4490e75046262907e1f48c7"},{"bytes":8696,"name":"publication.md","sha256":"fc0ab8b76984c721b31459a8fb2cbc7c4ec8b29cbadc550ebdf9ebee74ab02c9"},{"bytes":8355,"name":"publication.txt","sha256":"29d330543e049783ff905119ce7c2cf585e06a3f72c54354c0a99d5813a91abc"},{"bytes":2864,"name":"manifest.json","sha256":"3bac9856ce64badb033958a80ee624639160a41cd537ac1cfa93432b6fe4d859"},{"bytes":89,"name":"manifest.sig","sha256":"3ed9ae7dbc2c6d2c67417b20b9e4c01cb99fd63de602afaaf5eeeca81372af8c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"36dd51343af1802b35349d332356df5431c209c6cf119da60735eb83d995cd3c"}],"publication_id":"OT-2026-000089357"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089357
OpenTechnical

OT-2026-000089357

Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
29d330543e049783ff905119ce7c2cf585e06a3f72c54354c0a99d5813a91abc

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089357, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089357.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089357" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089357" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089357 Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089357 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089357 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089357 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089357", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1208 }, "figures": [], "files": [ { "bytes": 19231, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d17b97d42dc728c239c9a9cb0cfe91209816cc97f4490e75046262907e1f48c7" }, { "bytes": 8696, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fc0ab8b76984c721b31459a8fb2cbc7c4ec8b29cbadc550ebdf9ebee74ab02c9" }, { "bytes": 8355, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "29d330543e049783ff905119ce7c2cf585e06a3f72c54354c0a99d5813a91abc" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089357/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089357", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7cc1-b5fc-1bc82ce3bcda" } Y4U+7tkMA5AoQX5N3R0S6sFO34GEmsLxkC8zeiWG+Vx+Oyi/TLhwRfFDNNKEzY3tZ8oYeq4eIRUO8bChxnjAAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Y4U+7tkMA5AoQX5N3R0S6sFO34GEmsLxkC8zeiWG+Vx+Oyi/TLhwRfFDNNKEzY3tZ8oYeq4eIRUO8bChxnjAAA== {"files":[{"bytes":18978,"name":"index.html","sha256":"8c3b146cefa3032dc614c5fa761697a50be1de43a03004bd792f2e5208c4381b"},{"bytes":8486,"name":"publication.md","sha256":"71a56b3af4e6f2ec98e020c52c9f8475e2c295a6b7185e74090142e2a8507a6e"},{"bytes":8145,"name":"publication.txt","sha256":"ee506f3f4f6f860476f9a371447d972a81aaf66a308a08d0ac89d91593f86133"},{"bytes":2864,"name":"manifest.json","sha256":"c7b5f62834351c414834afd2fc8f3f69cd1c9aafeab15097b52c88b5c24858ed"},{"bytes":89,"name":"manifest.sig","sha256":"39856851945e96dc6a9c3fe714d4d0c45e587d59c43e5466a96ea10145d252ed"},{"bytes":227,"name":"manifest.sig.txt","sha256":"83de66545bf8e92ee0874c89ec0774d24ff7492bb8d2474852e84d19d337aeed"}],"publication_id":"OT-2026-000089358"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089358
OpenTechnical

OT-2026-000089358

Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
ee506f3f4f6f860476f9a371447d972a81aaf66a308a08d0ac89d91593f86133

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089358, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089358.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089358" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089358" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089358 Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089358 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089358 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089358 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089358", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1173 }, "figures": [], "files": [ { "bytes": 18978, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8c3b146cefa3032dc614c5fa761697a50be1de43a03004bd792f2e5208c4381b" }, { "bytes": 8486, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "71a56b3af4e6f2ec98e020c52c9f8475e2c295a6b7185e74090142e2a8507a6e" }, { "bytes": 8145, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ee506f3f4f6f860476f9a371447d972a81aaf66a308a08d0ac89d91593f86133" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089358/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089358", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-77fd-90ff-bc61e28e1d77" } JKB3foIl3hG+Gs+7wr4OwBgeb/fFLP3J1uf7C/Sca5uhdAwMpSXEalWQyKLWLeD1w/RUsq3gTzL8VQ5AGdtxAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: JKB3foIl3hG+Gs+7wr4OwBgeb/fFLP3J1uf7C/Sca5uhdAwMpSXEalWQyKLWLeD1w/RUsq3gTzL8VQ5AGdtxAw== {"files":[{"bytes":18420,"name":"index.html","sha256":"b0682bc22a141fe6ca23ec325185b90fbb55b5675b63beda25122172b6ea006c"},{"bytes":7999,"name":"publication.md","sha256":"424d67b66b26b2b23896c0cc12a438f3f25a6981bc97e40924cde2c6f9846541"},{"bytes":7664,"name":"publication.txt","sha256":"9f022b8828befa1fee1ab84486a14655fe870dfe0ff37ad392c96d7b6312b83f"},{"bytes":2852,"name":"manifest.json","sha256":"c12a758f7e7f84b5dc29ed944a80740b4579f190759623d896928b5b8864efff"},{"bytes":89,"name":"manifest.sig","sha256":"307b592998e2101e0280a95b86c1eb51cdf948468d3d4ce8d80c23f5e4262af1"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a87224c5c4063c54a3be5bbc3fc9086002a0fe8bc9cc93e3d0863e6730333bb6"}],"publication_id":"OT-2026-000089359"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089359
OpenTechnical

OT-2026-000089359

Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
9f022b8828befa1fee1ab84486a14655fe870dfe0ff37ad392c96d7b6312b83f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089359, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089359.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089359" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089359" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089359 Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089359 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089359 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089359 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089359", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1102 }, "figures": [], "files": [ { "bytes": 18420, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b0682bc22a141fe6ca23ec325185b90fbb55b5675b63beda25122172b6ea006c" }, { "bytes": 7999, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "424d67b66b26b2b23896c0cc12a438f3f25a6981bc97e40924cde2c6f9846541" }, { "bytes": 7664, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9f022b8828befa1fee1ab84486a14655fe870dfe0ff37ad392c96d7b6312b83f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089359/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089359", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7d24-9b61-feeda8a3a5e0" } 3N1RD6lUUqggPAy/3HMS5zwMLWOG216zz6P91jwPntSgbMk8ppPDuVyVYvIyFnHQPg7t+Na4FrcFThaF7RXaDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 3N1RD6lUUqggPAy/3HMS5zwMLWOG216zz6P91jwPntSgbMk8ppPDuVyVYvIyFnHQPg7t+Na4FrcFThaF7RXaDg== {"files":[{"bytes":19235,"name":"index.html","sha256":"44d4d8fc60de0513764f8e2ae4d06a9809bc27f3ae67306c7f10dd21cc997e5a"},{"bytes":8700,"name":"publication.md","sha256":"b57333aabadc95c6e16fff634c799eea4b29c639611304e0954f3cc40b2f9b1b"},{"bytes":8359,"name":"publication.txt","sha256":"bddeb4cb3ebbef533494df7aab817cd3983497e4562e7b2c04f3d8d9662d33b5"},{"bytes":2864,"name":"manifest.json","sha256":"3710a58aab8cba3037ce5425194a0be67004ffb6d6f63fc3fc0bbe89901347cc"},{"bytes":89,"name":"manifest.sig","sha256":"9ef5dc3be0086175522279c2d80afe286927bd091e10e14e634b3f31d809373d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"85e19a12e380a072f279982252ba8de9cb2ce6e15a1b9a2151ef1381e5d9eae2"}],"publication_id":"OT-2026-000089360"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089360
OpenTechnical

OT-2026-000089360

Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
bddeb4cb3ebbef533494df7aab817cd3983497e4562e7b2c04f3d8d9662d33b5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089360, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089360.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089360" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089360" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089360 Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089360 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089360 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089360 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089360", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1208 }, "figures": [], "files": [ { "bytes": 19235, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "44d4d8fc60de0513764f8e2ae4d06a9809bc27f3ae67306c7f10dd21cc997e5a" }, { "bytes": 8700, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b57333aabadc95c6e16fff634c799eea4b29c639611304e0954f3cc40b2f9b1b" }, { "bytes": 8359, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "bddeb4cb3ebbef533494df7aab817cd3983497e4562e7b2c04f3d8d9662d33b5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089360/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089360", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7f09-a2f3-0e7e00267cfd" } +R03P1r5DqV7+6M+V6DBJblIVrWBc2m7qhaUBSVP/FGeayYBOlOd/sIQqr0Vz5fog4FAn5GvNqsJ1z+oDK08DQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: +R03P1r5DqV7+6M+V6DBJblIVrWBc2m7qhaUBSVP/FGeayYBOlOd/sIQqr0Vz5fog4FAn5GvNqsJ1z+oDK08DQ== {"files":[{"bytes":18982,"name":"index.html","sha256":"4be406364fe6d261745bf8d53000041150e9911a0e67e7f3698f642d756cab97"},{"bytes":8490,"name":"publication.md","sha256":"63f7170318e8e66e18a13239634ab7202270038e0a77ac8ad00d1ddbd92d5f2e"},{"bytes":8149,"name":"publication.txt","sha256":"ccc4d15864a034b5b60e53a683c7883a052d5f0d5b707fd298a8cd9355d96454"},{"bytes":2864,"name":"manifest.json","sha256":"de34ddbb97b68668b9a16859b6deef81af66acc413d0209d81bd336eaff55d56"},{"bytes":89,"name":"manifest.sig","sha256":"3e96d4599446e38100552ad41becc3d5f3556d386e8c56101dcfe8c997b7f6b7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d0f8cc907643d32af1e8485de1f3bd9c4e31e84b1f62da5f84456313e1c09a44"}],"publication_id":"OT-2026-000089361"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089361
OpenTechnical

OT-2026-000089361

Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
ccc4d15864a034b5b60e53a683c7883a052d5f0d5b707fd298a8cd9355d96454

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089361, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089361.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089361" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089361" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089361 Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089361 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089361 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089361 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089361", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1173 }, "figures": [], "files": [ { "bytes": 18982, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4be406364fe6d261745bf8d53000041150e9911a0e67e7f3698f642d756cab97" }, { "bytes": 8490, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "63f7170318e8e66e18a13239634ab7202270038e0a77ac8ad00d1ddbd92d5f2e" }, { "bytes": 8149, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ccc4d15864a034b5b60e53a683c7883a052d5f0d5b707fd298a8cd9355d96454" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089361/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089361", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7ada-a8f3-011b8e9935f0" } nKYA983p9qG8UMsqA5OnRqXEDqzC9IUy553LJSQHC8FcZUB4C2bQl5V24yulj7ER5/P4UzlQwE8bkgCMVM6rAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: nKYA983p9qG8UMsqA5OnRqXEDqzC9IUy553LJSQHC8FcZUB4C2bQl5V24yulj7ER5/P4UzlQwE8bkgCMVM6rAA== {"files":[{"bytes":18609,"name":"index.html","sha256":"0f002c82ebf8e111fd571eed0a9886b78dac835c245821764999b44dba514e6b"},{"bytes":8156,"name":"publication.md","sha256":"38f3ce92c80ea3906441d25dd7722e2bd8ca1b25be79a8b810404323e8b34f0c"},{"bytes":7831,"name":"publication.txt","sha256":"f1de61a85fc95b8acd0f8a2fcc408ed1c50805dd5a1f0f925fe9f2266b1c6586"},{"bytes":2831,"name":"manifest.json","sha256":"57209c7b13ca935af9bf4aea741943eb59f686764dff3e16ecb5b9dde2225b7a"},{"bytes":89,"name":"manifest.sig","sha256":"308b13cca3d4e4e37a563e8b32d881350d0cc0992ce236b6cbc94fcfcbef2586"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f8acba6aecc7c7dabbd19b2a687f30223a3158fb8109af9f34c117075bad79bb"}],"publication_id":"OT-2026-000089362"} Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089362
OpenTechnical

OT-2026-000089362

Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
f1de61a85fc95b8acd0f8a2fcc408ed1c50805dd5a1f0f925fe9f2266b1c6586

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089362, “Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089362.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089362" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089362" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089362 Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089362 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089362 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089362 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089362", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1142 }, "figures": [], "files": [ { "bytes": 18609, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0f002c82ebf8e111fd571eed0a9886b78dac835c245821764999b44dba514e6b" }, { "bytes": 8156, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "38f3ce92c80ea3906441d25dd7722e2bd8ca1b25be79a8b810404323e8b34f0c" }, { "bytes": 7831, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f1de61a85fc95b8acd0f8a2fcc408ed1c50805dd5a1f0f925fe9f2266b1c6586" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089362/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089362", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-719b-b385-b01ee9bd3b47" } hV7lda1nd4uBN0C8gTL5xkvGXyf+9JVHEEY3x5n+l7oAKVlYp4jLw9pd+5/MJKD/sziOvGFdQ7F5mdNgdlOMAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: hV7lda1nd4uBN0C8gTL5xkvGXyf+9JVHEEY3x5n+l7oAKVlYp4jLw9pd+5/MJKD/sziOvGFdQ7F5mdNgdlOMAg== {"files":[{"bytes":19424,"name":"index.html","sha256":"4213e5e8b926219095ab8b5ffb6c2b987902b0b1026e9e8bdefbc42ddf5cd69a"},{"bytes":8857,"name":"publication.md","sha256":"e718c2489b73d53c0f172bdd29df0389d4537bdc3561390c82d51061f1cf838a"},{"bytes":8526,"name":"publication.txt","sha256":"b784a5176a007418abdeee0c6ab3e750a3c01d9d1da83d43fd7a67bc3b254efe"},{"bytes":2843,"name":"manifest.json","sha256":"13f6df769c9cd43d638428c282055ceda350cc06b583247bcd5d5955bcbd723f"},{"bytes":89,"name":"manifest.sig","sha256":"a2cf81a044fe13b10ddc4a0c00c39288f6b5f26f41b5091d8ed44a7b851e1ea5"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3880a0490284cad341c0c87e4cb86425b6778f87d243e183d0143857e8602d11"}],"publication_id":"OT-2026-000089363"} Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089363
OpenTechnical

OT-2026-000089363

Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
b784a5176a007418abdeee0c6ab3e750a3c01d9d1da83d43fd7a67bc3b254efe

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089363, “Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089363.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089363" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089363" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089363 Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089363 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089363 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089363 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089363", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1248 }, "figures": [], "files": [ { "bytes": 19424, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4213e5e8b926219095ab8b5ffb6c2b987902b0b1026e9e8bdefbc42ddf5cd69a" }, { "bytes": 8857, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e718c2489b73d53c0f172bdd29df0389d4537bdc3561390c82d51061f1cf838a" }, { "bytes": 8526, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b784a5176a007418abdeee0c6ab3e750a3c01d9d1da83d43fd7a67bc3b254efe" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089363/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089363", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7fbb-89fd-cfdcf18418ae" } L6ninzGEp02NAS2aKlkvDk+vHRhvM1Xbcv1eTwr46b1JBVOlW1HGAu2YH87cpsXCJyiHC+LMuSGy3EIE8fP1DQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: L6ninzGEp02NAS2aKlkvDk+vHRhvM1Xbcv1eTwr46b1JBVOlW1HGAu2YH87cpsXCJyiHC+LMuSGy3EIE8fP1DQ== {"files":[{"bytes":18491,"name":"index.html","sha256":"5753b2bf9343fce29157541ebb97971b0dded674880b6829727646c75f1fa681"},{"bytes":8079,"name":"publication.md","sha256":"a3fc5bd56af38fa3690000d9ea2e2353c1cbeeecac9dd0b75d06deef99e8b765"},{"bytes":7753,"name":"publication.txt","sha256":"975a5c72d340326ce217a2990f9e8f451e5397bae512ded4dc1abdeccf65b278"},{"bytes":2832,"name":"manifest.json","sha256":"083f752d86e91ac0cee599ee2b140381ab470f0cc26411b7ca8f447ec504829b"},{"bytes":89,"name":"manifest.sig","sha256":"626432f19b2eb387df8385980a459480a17110775bcb1d74ebd106271bd6e4c9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"34d39a370a1178afefb259b4c855542e732198f19b2eda7113c3273391663f13"}],"publication_id":"OT-2026-000089364"} Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089364
OpenTechnical

OT-2026-000089364

Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
975a5c72d340326ce217a2990f9e8f451e5397bae512ded4dc1abdeccf65b278

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089364, “Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089364.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089364" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089364" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089364 Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089364 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089364 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089364 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089364", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1131 }, "figures": [], "files": [ { "bytes": 18491, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5753b2bf9343fce29157541ebb97971b0dded674880b6829727646c75f1fa681" }, { "bytes": 8079, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a3fc5bd56af38fa3690000d9ea2e2353c1cbeeecac9dd0b75d06deef99e8b765" }, { "bytes": 7753, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "975a5c72d340326ce217a2990f9e8f451e5397bae512ded4dc1abdeccf65b278" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089364/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089364", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-72e4-b481-0d55e1358e1b" } Fdmv0ePdX7B2L6NopEGYaA/d4fIYXE1E2bONYxrsl8+QFK8IkHeDzjVhfiqy64OvpZRQrqwUPHy2ZV/mrap9AQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Fdmv0ePdX7B2L6NopEGYaA/d4fIYXE1E2bONYxrsl8+QFK8IkHeDzjVhfiqy64OvpZRQrqwUPHy2ZV/mrap9AQ== {"files":[{"bytes":19306,"name":"index.html","sha256":"4ae79fd80913d76e9015f2ff812fd5f268584a6d03a6c69affcab4d9eec19c9b"},{"bytes":8780,"name":"publication.md","sha256":"a92174105a658d004df4208192dde1435e62d007ba27c4ff4ce12e002ed525f9"},{"bytes":8448,"name":"publication.txt","sha256":"f7d8ff57ebd444c1bde1a8f6dc592ea1bbdb555d783097f5adac07505d277131"},{"bytes":2844,"name":"manifest.json","sha256":"184658cde3145df4a17310507b0a2eff06a3f6009caf01d6eb6d20bf19e5d4a2"},{"bytes":89,"name":"manifest.sig","sha256":"00f7fd8c1d675e1c42b554f6b7c88a3e9ba5db746e4834c827324248432408eb"},{"bytes":227,"name":"manifest.sig.txt","sha256":"620fca148da4b15c06c4a2eabba6e93d9be853049ebf0ea29bd450b956481023"}],"publication_id":"OT-2026-000089365"} Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089365
OpenTechnical

OT-2026-000089365

Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f7d8ff57ebd444c1bde1a8f6dc592ea1bbdb555d783097f5adac07505d277131

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089365, “Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089365.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089365" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089365" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089365 Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089365 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089365 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089365 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089365", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1237 }, "figures": [], "files": [ { "bytes": 19306, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4ae79fd80913d76e9015f2ff812fd5f268584a6d03a6c69affcab4d9eec19c9b" }, { "bytes": 8780, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a92174105a658d004df4208192dde1435e62d007ba27c4ff4ce12e002ed525f9" }, { "bytes": 8448, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f7d8ff57ebd444c1bde1a8f6dc592ea1bbdb555d783097f5adac07505d277131" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089365/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089365", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7c6d-bc9f-9a03175d13cc" } X2yDxFd2d8kp8vJONSdcea6wsU/MZeUbNjMjGIGhZh0yuWD5XstVAX7O/Sp6CEyLXdalKVZYjEAzK/s2qPPhBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: X2yDxFd2d8kp8vJONSdcea6wsU/MZeUbNjMjGIGhZh0yuWD5XstVAX7O/Sp6CEyLXdalKVZYjEAzK/s2qPPhBw== {"files":[{"bytes":19053,"name":"index.html","sha256":"917e79342264513093397b408b357490e3d6b73b57369771a1426830d6608304"},{"bytes":8570,"name":"publication.md","sha256":"06049a594270425b04f4b93f28c37d7be1f7db56f001ce16f4b8f4d924000510"},{"bytes":8238,"name":"publication.txt","sha256":"a8f200ada7568d41fe46dc87d07582de0060cba03e393d6f1116e93b617403be"},{"bytes":2844,"name":"manifest.json","sha256":"c9092fc549cd8dd1a834286646d2c328dc118b76c5de3d976c2ccc51dc4a4d43"},{"bytes":89,"name":"manifest.sig","sha256":"d4fbcc8cc1b783010c0895feb9519be22048790f97bc3b9ccd8e5b07b47093e6"},{"bytes":227,"name":"manifest.sig.txt","sha256":"fad40c2563aaa918c25734e78eaf9c6005dc1082e2c417722da0b63d65f0a0d0"}],"publication_id":"OT-2026-000089366"} Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089366
OpenTechnical

OT-2026-000089366

Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a8f200ada7568d41fe46dc87d07582de0060cba03e393d6f1116e93b617403be

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089366, “Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089366.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089366" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089366" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089366 Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089366 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089366 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089366 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089366", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19053, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "917e79342264513093397b408b357490e3d6b73b57369771a1426830d6608304" }, { "bytes": 8570, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "06049a594270425b04f4b93f28c37d7be1f7db56f001ce16f4b8f4d924000510" }, { "bytes": 8238, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a8f200ada7568d41fe46dc87d07582de0060cba03e393d6f1116e93b617403be" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089366/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089366", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-776e-8f91-3f74dd4d8632" } zE1nRjM5wsj6ee4ICf09S7+N/XmrW0Pp+jsKXLAkm3aZ8kqhH99ry0HBgpwfrYidiiePGcvqKEbOCA6wzpYQBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: zE1nRjM5wsj6ee4ICf09S7+N/XmrW0Pp+jsKXLAkm3aZ8kqhH99ry0HBgpwfrYidiiePGcvqKEbOCA6wzpYQBQ== {"files":[{"bytes":18437,"name":"index.html","sha256":"5e7f466afb79efa9166462f49a1f0aa544a5539e9a587f9f40d68f85f86e3160"},{"bytes":8025,"name":"publication.md","sha256":"7c67f951cb173cca0e4d89a602ccad3f3dea2480997e6b4ee3e16a991c6fe1f8"},{"bytes":7699,"name":"publication.txt","sha256":"620a3c7eb9a7b1c78bfb6587a9fd270fc8c0ff24ea7a7e43e46136fa459d2028"},{"bytes":2832,"name":"manifest.json","sha256":"0e8cee112d67c992645cfcfd98d58241883af9072ab166bfd4fdfefda95b9d42"},{"bytes":89,"name":"manifest.sig","sha256":"4d813f47a73cb569f4a57d95a383866b67a0036e7a3c255bc4b5fa254c5e129d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"12876cba755c3571984e0447151ab076b510475c2943d120d7117b07ed26cc9d"}],"publication_id":"OT-2026-000089367"} Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089367
OpenTechnical

OT-2026-000089367

Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
620a3c7eb9a7b1c78bfb6587a9fd270fc8c0ff24ea7a7e43e46136fa459d2028

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089367, “Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089367.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089367" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089367" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089367 Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089367 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089367 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089367 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089367", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1116 }, "figures": [], "files": [ { "bytes": 18437, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5e7f466afb79efa9166462f49a1f0aa544a5539e9a587f9f40d68f85f86e3160" }, { "bytes": 8025, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7c67f951cb173cca0e4d89a602ccad3f3dea2480997e6b4ee3e16a991c6fe1f8" }, { "bytes": 7699, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "620a3c7eb9a7b1c78bfb6587a9fd270fc8c0ff24ea7a7e43e46136fa459d2028" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089367/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089367", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7a91-9430-f12cabbd12d7" } mSDWxCRXglIt+QYwMKLOMA7+vO6AbRwjMQLxMBCajzGuYF45peCnTfcEOtg6KRhdSt9eZRTBc/eQskkEq9OtCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: mSDWxCRXglIt+QYwMKLOMA7+vO6AbRwjMQLxMBCajzGuYF45peCnTfcEOtg6KRhdSt9eZRTBc/eQskkEq9OtCg== {"files":[{"bytes":19252,"name":"index.html","sha256":"97ff793753b5ad0d028a27eff2d4b7a9c07c9a9ad3b9ddc41bad61b79ff4cb44"},{"bytes":8726,"name":"publication.md","sha256":"1596213fcc845126d90cea3abbe2749d08a3d47c82009097dea11b2727e4ba5a"},{"bytes":8394,"name":"publication.txt","sha256":"c5b698cfee512c6366031623cb9aa73d18e088bda13a4c09add8b6126327eba4"},{"bytes":2844,"name":"manifest.json","sha256":"f226f78043dd9a4e78d330be3bee39e31fe442cc79b815705bd4003dca55bdaa"},{"bytes":89,"name":"manifest.sig","sha256":"fb6e6c7b815ad940a9325b9bd970f21d7eae161d25b9de78fce66799d4cd7614"},{"bytes":227,"name":"manifest.sig.txt","sha256":"db50bedee0efeb6893b99024e7f9362a1328c9f87a46eb93cc0c7fd745e0af15"}],"publication_id":"OT-2026-000089368"} Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089368
OpenTechnical

OT-2026-000089368

Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c5b698cfee512c6366031623cb9aa73d18e088bda13a4c09add8b6126327eba4

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089368, “Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089368.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089368" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089368" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089368 Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089368 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089368 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089368 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089368", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1222 }, "figures": [], "files": [ { "bytes": 19252, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "97ff793753b5ad0d028a27eff2d4b7a9c07c9a9ad3b9ddc41bad61b79ff4cb44" }, { "bytes": 8726, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1596213fcc845126d90cea3abbe2749d08a3d47c82009097dea11b2727e4ba5a" }, { "bytes": 8394, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c5b698cfee512c6366031623cb9aa73d18e088bda13a4c09add8b6126327eba4" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089368/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089368", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7f93-a139-08e7e37468eb" } aewpsN/EXxapf6by45CWWoLgXNbrBEarMyP08mzhoWeH2qZ25AIGJyCMj8igiH/llOn7etyaa9u8zkARmBnCAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: aewpsN/EXxapf6by45CWWoLgXNbrBEarMyP08mzhoWeH2qZ25AIGJyCMj8igiH/llOn7etyaa9u8zkARmBnCAA== {"files":[{"bytes":18999,"name":"index.html","sha256":"5a57a5860f6b795566331d584b515562b9b44d07df81256278cb660b256a4156"},{"bytes":8516,"name":"publication.md","sha256":"8fb3fc49f57e24d293e272cedfdfd9d0d068dcd2f214c01fcc861d0c6584fd94"},{"bytes":8184,"name":"publication.txt","sha256":"54c66dd792cc504d081c301a53f0429ce91d0d2e0f209c395ed2797f57d9893b"},{"bytes":2844,"name":"manifest.json","sha256":"27d12f82a34f50f5adf24eee1a3e46a0ee38cc6d678595122f2b472af7022920"},{"bytes":89,"name":"manifest.sig","sha256":"423760502569ac163fc5f63b499db85a67a65005610518bccb3e95d64f434285"},{"bytes":227,"name":"manifest.sig.txt","sha256":"fc0e9e99f258d20f4590a063edfa212401575a0a105977aa465bb8526f3726ce"}],"publication_id":"OT-2026-000089369"} Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089369
OpenTechnical

OT-2026-000089369

Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
54c66dd792cc504d081c301a53f0429ce91d0d2e0f209c395ed2797f57d9893b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089369, “Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089369.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089369" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089369" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089369 Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089369 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089369 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089369 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089369", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1187 }, "figures": [], "files": [ { "bytes": 18999, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5a57a5860f6b795566331d584b515562b9b44d07df81256278cb660b256a4156" }, { "bytes": 8516, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8fb3fc49f57e24d293e272cedfdfd9d0d068dcd2f214c01fcc861d0c6584fd94" }, { "bytes": 8184, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "54c66dd792cc504d081c301a53f0429ce91d0d2e0f209c395ed2797f57d9893b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089369/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089369", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-758c-9bc4-dac6ec60f209" } nhwhwo5XpBGXeYqW9lYvV3n0XHf/Nl48nwPkXjHjteL2q4m15clW2Uro6ByMVYi/XIKBfEiod2KkNLQwuKrJCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: nhwhwo5XpBGXeYqW9lYvV3n0XHf/Nl48nwPkXjHjteL2q4m15clW2Uro6ByMVYi/XIKBfEiod2KkNLQwuKrJCw== {"files":[{"bytes":18191,"name":"index.html","sha256":"7435880f4773442623ba0897ab1da9599e813747d9c1330e624003aed556f650"},{"bytes":7827,"name":"publication.md","sha256":"4a9461f9cb88d099d9fc3a89e9455988f1bc6ef9c42f9956f8a00b7f54b5e9e4"},{"bytes":7499,"name":"publication.txt","sha256":"b2987a355ee22872be923113e215f3ac58f3d7558d15b8b4796ec6dd8c420a87"},{"bytes":2845,"name":"manifest.json","sha256":"6c1e6e77d135da95481ae26943259a731c99a7309e4828b126f5fb44719ac604"},{"bytes":89,"name":"manifest.sig","sha256":"16df8f373e4dbf610c86237d1d276e89194cd1ad4e1857dd9188df5cdf6361f3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"115882da607b6b1e2785e66f64b36fffc2f8b7a7b7b12b61980b02e570268e74"}],"publication_id":"OT-2026-000089370"} Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089370
OpenTechnical

OT-2026-000089370

Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
b2987a355ee22872be923113e215f3ac58f3d7558d15b8b4796ec6dd8c420a87

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089370, “Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089370.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089370" title: "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089370" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089370 Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089370 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089370 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089370 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089370", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1079 }, "figures": [], "files": [ { "bytes": 18191, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7435880f4773442623ba0897ab1da9599e813747d9c1330e624003aed556f650" }, { "bytes": 7827, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4a9461f9cb88d099d9fc3a89e9455988f1bc6ef9c42f9956f8a00b7f54b5e9e4" }, { "bytes": 7499, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b2987a355ee22872be923113e215f3ac58f3d7558d15b8b4796ec6dd8c420a87" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089370/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089370", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7674-88ed-42fdd3e5be4c" } DEHYBUcCoLqq13txVoovLzY4MzKp2VSlsXdB0yZAWEvJngvboIzIOvcWfPT3tD4wn8MT23kiDl9oLoYD5wahCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: DEHYBUcCoLqq13txVoovLzY4MzKp2VSlsXdB0yZAWEvJngvboIzIOvcWfPT3tD4wn8MT23kiDl9oLoYD5wahCw== {"files":[{"bytes":19006,"name":"index.html","sha256":"2fea2854a40a725a45380bebeae3b160682ccaafc56cbe08b672c2c0d5063991"},{"bytes":8528,"name":"publication.md","sha256":"abf5c31b2d72a6d541a9317cf7ea39dc64e03ec39ac186471bb461c9acd333aa"},{"bytes":8194,"name":"publication.txt","sha256":"5a253c2f6a4f36e33acd014290e5cdfd8521fbb2ebc3adb0c2f48310ad08e221"},{"bytes":2857,"name":"manifest.json","sha256":"74d17347c7061b60fe0ce81126451f96ddf6b0ea28b45cf78127f22600455de6"},{"bytes":89,"name":"manifest.sig","sha256":"392b649763f1b10af5cfd605b2d62e42e3dfff0e1066e7eb03ef3d5409ded9fe"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d5aea7d6c069ee5a10eec8ab4c7abc112d208d404a3b8e289c15be8f8b745c4e"}],"publication_id":"OT-2026-000089371"} Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089371
OpenTechnical

OT-2026-000089371

Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
5a253c2f6a4f36e33acd014290e5cdfd8521fbb2ebc3adb0c2f48310ad08e221

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089371, “Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089371.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089371" title: "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089371" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089371 Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089371 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089371 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089371 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089371", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1185 }, "figures": [], "files": [ { "bytes": 19006, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2fea2854a40a725a45380bebeae3b160682ccaafc56cbe08b672c2c0d5063991" }, { "bytes": 8528, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "abf5c31b2d72a6d541a9317cf7ea39dc64e03ec39ac186471bb461c9acd333aa" }, { "bytes": 8194, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5a253c2f6a4f36e33acd014290e5cdfd8521fbb2ebc3adb0c2f48310ad08e221" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089371/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089371", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7bb0-869e-3a95cc38db41" } A6cFQd9mwBRNphoRQp4+paUf9CkMDDBr/76mGS30p/yI0JMIvJUmAiqQ1GDMzR8f3ltSap0Iq5M/68XJZPmKAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: A6cFQd9mwBRNphoRQp4+paUf9CkMDDBr/76mGS30p/yI0JMIvJUmAiqQ1GDMzR8f3ltSap0Iq5M/68XJZPmKAg== {"files":[{"bytes":18753,"name":"index.html","sha256":"1c8d23e08bab7012f21a89dd9aaca26f97e9e4cbe8270a1f9bbb6df95e93f82a"},{"bytes":8318,"name":"publication.md","sha256":"9c6b9896733ac5d6d2c5e6ba8d16c26fe67b5e487c87a2e880aac05c45ac7618"},{"bytes":7984,"name":"publication.txt","sha256":"64d6147ca549725cc05ab340dbe7d6cd2afefee24cfa0e0e0d5abd96a6a27dd6"},{"bytes":2857,"name":"manifest.json","sha256":"db9570d9bf1ca69ab793de4c379943acfb408f61fd45220fcd2b354d179c1f99"},{"bytes":89,"name":"manifest.sig","sha256":"342b1b89f04a9fc1d8fcda790e6aa22a8b67bd510fcc6e950997a2efa597dd22"},{"bytes":227,"name":"manifest.sig.txt","sha256":"13e1a0e23e987a07f622b5a5c3bbfa7ab2ebd3abd67b04a4a641b25c5c494f3b"}],"publication_id":"OT-2026-000089372"} Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089372
OpenTechnical

OT-2026-000089372

Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
64d6147ca549725cc05ab340dbe7d6cd2afefee24cfa0e0e0d5abd96a6a27dd6

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089372, “Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089372.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089372" title: "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089372" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089372 Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089372 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089372 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089372 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089372", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1150 }, "figures": [], "files": [ { "bytes": 18753, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1c8d23e08bab7012f21a89dd9aaca26f97e9e4cbe8270a1f9bbb6df95e93f82a" }, { "bytes": 8318, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9c6b9896733ac5d6d2c5e6ba8d16c26fe67b5e487c87a2e880aac05c45ac7618" }, { "bytes": 7984, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "64d6147ca549725cc05ab340dbe7d6cd2afefee24cfa0e0e0d5abd96a6a27dd6" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089372/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089372", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7d2e-94f4-d9f4afdd659c" } 4GL6zIVaBRYnCXPfAjw8V+f6bA68us23iD7KEYwGYFzdEVIZ0iMqYugpvoFHJ35aXJ2uaR5kbf+U/tk5zCPABA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 4GL6zIVaBRYnCXPfAjw8V+f6bA68us23iD7KEYwGYFzdEVIZ0iMqYugpvoFHJ35aXJ2uaR5kbf+U/tk5zCPABA== {"files":[{"bytes":18191,"name":"index.html","sha256":"6834b2c9444f4be23c86737a54ea8b257cfc463e04f603b4e89490ddd42d2660"},{"bytes":7827,"name":"publication.md","sha256":"a8fd0bfb36875b519eff7e15d01fcbb89bf6dc12c7d8ca4ad1dbb617d2dbcbfb"},{"bytes":7499,"name":"publication.txt","sha256":"5cdfd08efe48e0fffaf903ecfb36ef8acd0675e52cd9d67c19311af8452bd44b"},{"bytes":2845,"name":"manifest.json","sha256":"01a0d816af4b89ba940b17632460e863e9995ad36a7342c20a49a5ca444bd140"},{"bytes":89,"name":"manifest.sig","sha256":"0d113a54bcb7b24bba4108db6144181b1d35a0e9e5b4ff4861555e95f3bffb1e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"df9c675c078de387612ed38bf8f7979f6d7f48b74227fdcf74ffc309ffa226a6"}],"publication_id":"OT-2026-000089373"} Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089373
OpenTechnical

OT-2026-000089373

Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
5cdfd08efe48e0fffaf903ecfb36ef8acd0675e52cd9d67c19311af8452bd44b

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089373, “Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089373.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089373" title: "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089373" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089373 Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089373 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089373 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089373 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089373", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1079 }, "figures": [], "files": [ { "bytes": 18191, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6834b2c9444f4be23c86737a54ea8b257cfc463e04f603b4e89490ddd42d2660" }, { "bytes": 7827, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a8fd0bfb36875b519eff7e15d01fcbb89bf6dc12c7d8ca4ad1dbb617d2dbcbfb" }, { "bytes": 7499, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5cdfd08efe48e0fffaf903ecfb36ef8acd0675e52cd9d67c19311af8452bd44b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089373/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089373", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-76b0-9280-102d6248712f" } c85Cr3sEuVj877pOhvAT25C9HRSJZK7e1yzC7tk43eyA1nxG6Dd93U8QeCByITk9TFIfd3Mm1xyBZ0zEd3G8BA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: c85Cr3sEuVj877pOhvAT25C9HRSJZK7e1yzC7tk43eyA1nxG6Dd93U8QeCByITk9TFIfd3Mm1xyBZ0zEd3G8BA== {"files":[{"bytes":19006,"name":"index.html","sha256":"12257e1cca5c347eb204f92f9f8580510209c5916d6165b8fb289347a40b0375"},{"bytes":8528,"name":"publication.md","sha256":"16b3fc05e10652d1ffc656eaf148a7600a0b41f78294b1c8057cef00781ffb01"},{"bytes":8194,"name":"publication.txt","sha256":"0d4eb2fc1640aec1b7f1652471988d23893b9edd3b00b9cacebe85efb4ace4a5"},{"bytes":2857,"name":"manifest.json","sha256":"4e17fff962f92f6b329cc71cca4e3d517dc181e8dd7e04773c0109c8962b1aaf"},{"bytes":89,"name":"manifest.sig","sha256":"36f02868cd805d4255460bfbebbec286fedf26d01ec6e00c823fb9f2ea0a8129"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a5e091fcddfa034cb3a8b8708a03a9dda246d0d6a0b8dcd847c66bb405e316f0"}],"publication_id":"OT-2026-000089374"} Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089374
OpenTechnical

OT-2026-000089374

Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
0d4eb2fc1640aec1b7f1652471988d23893b9edd3b00b9cacebe85efb4ace4a5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089374, “Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089374.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089374" title: "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089374" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089374 Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089374 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089374 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089374 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089374", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1185 }, "figures": [], "files": [ { "bytes": 19006, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "12257e1cca5c347eb204f92f9f8580510209c5916d6165b8fb289347a40b0375" }, { "bytes": 8528, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "16b3fc05e10652d1ffc656eaf148a7600a0b41f78294b1c8057cef00781ffb01" }, { "bytes": 8194, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0d4eb2fc1640aec1b7f1652471988d23893b9edd3b00b9cacebe85efb4ace4a5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089374/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089374", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-766a-8965-cad8410053fb" } L78hybNudI91wiaQ5ehRaWh94V9kK2PRozbfgLWveijsuzdjtFXHvMF6/MI32REqBlbEhz4GTa7cAvJBJCMZDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: L78hybNudI91wiaQ5ehRaWh94V9kK2PRozbfgLWveijsuzdjtFXHvMF6/MI32REqBlbEhz4GTa7cAvJBJCMZDQ== {"files":[{"bytes":18753,"name":"index.html","sha256":"3aa6aa28ed6dbc32033236a25cb42ac68d3c7ff837d30cc8c7f92bb77746e687"},{"bytes":8318,"name":"publication.md","sha256":"4edd86a9d65a5f5f1b3f501a1be17566ed3bd976cc13216ea1f94eeb91b26c66"},{"bytes":7984,"name":"publication.txt","sha256":"837e8f041e8c2a946e43601340dd86e5cbed495f31a60653e7c5003450ef5947"},{"bytes":2857,"name":"manifest.json","sha256":"ef511c115ce09e46437d46df97382a66c727153f2dab05122c075ac2a80ea6fb"},{"bytes":89,"name":"manifest.sig","sha256":"c36a554485632d213a66f0e25966efa88df6c232fe6202db47ae0f4f6f370d4d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c6be7721ca1a5527efeaca61d8ba90131211348f8559480e31bfef8b2dbc94b2"}],"publication_id":"OT-2026-000089375"} Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089375
OpenTechnical

OT-2026-000089375

Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
837e8f041e8c2a946e43601340dd86e5cbed495f31a60653e7c5003450ef5947

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089375, “Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089375.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089375" title: "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089375" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089375 Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089375 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089375 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089375 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089375", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1150 }, "figures": [], "files": [ { "bytes": 18753, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3aa6aa28ed6dbc32033236a25cb42ac68d3c7ff837d30cc8c7f92bb77746e687" }, { "bytes": 8318, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4edd86a9d65a5f5f1b3f501a1be17566ed3bd976cc13216ea1f94eeb91b26c66" }, { "bytes": 7984, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "837e8f041e8c2a946e43601340dd86e5cbed495f31a60653e7c5003450ef5947" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089375/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089375", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-78f3-bfc8-da2977dc1ed1" } AZGbqmK7xoja+mhgRe2nJdltpqllh1l56s/MpOiEIulkSvbyBykbizovihYK6bo+QueJOCb05xiHPMrTl8/PAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: AZGbqmK7xoja+mhgRe2nJdltpqllh1l56s/MpOiEIulkSvbyBykbizovihYK6bo+QueJOCb05xiHPMrTl8/PAw== {"files":[{"bytes":18286,"name":"index.html","sha256":"a22b174eadd0329799e83c20ee50546a16e552ff71cb1c6e7f69372680cb9eca"},{"bytes":7912,"name":"publication.md","sha256":"a80c585ebe3d3d90406dec9b74aaa1717744b71c76caea07499887dd0f4acf2c"},{"bytes":7579,"name":"publication.txt","sha256":"9bf9e14e01c863c7c4ebd5f062d70c28a15270da186102936b0db8e78b89e973"},{"bytes":2850,"name":"manifest.json","sha256":"6894b07658a5c4afb0440ce5e1c1806ecbef10e603815504845a1e1ed4f8801a"},{"bytes":89,"name":"manifest.sig","sha256":"3a7995d84d9c4ebd18335144336ed638e35aa28f387b8852aa3989de6fdebf60"},{"bytes":227,"name":"manifest.sig.txt","sha256":"063ae50691e68367947c2823cc0c7e780c75e29c3be32cb48221532a51a3c936"}],"publication_id":"OT-2026-000089376"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089376
OpenTechnical

OT-2026-000089376

Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
9bf9e14e01c863c7c4ebd5f062d70c28a15270da186102936b0db8e78b89e973

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089376, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089376.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089376" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089376" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089376 Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089376 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089376 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089376 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089376", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18286, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a22b174eadd0329799e83c20ee50546a16e552ff71cb1c6e7f69372680cb9eca" }, { "bytes": 7912, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a80c585ebe3d3d90406dec9b74aaa1717744b71c76caea07499887dd0f4acf2c" }, { "bytes": 7579, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9bf9e14e01c863c7c4ebd5f062d70c28a15270da186102936b0db8e78b89e973" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089376/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089376", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7780-8831-af1c57b8a8a0" } 7SCxytXgajk8Vi5IKZr56Dl1hCUwiBbCp1YqeuWkH95etWP6cuC+4q5mf+9MGvURBNrIzhSsFtUDop3V2oQJBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 7SCxytXgajk8Vi5IKZr56Dl1hCUwiBbCp1YqeuWkH95etWP6cuC+4q5mf+9MGvURBNrIzhSsFtUDop3V2oQJBg== {"files":[{"bytes":19101,"name":"index.html","sha256":"5b14db826f3fff3aedc1d099ba9949601ccd329ca5f92eaa8b0dda951477a7d4"},{"bytes":8613,"name":"publication.md","sha256":"00f8cf1c9675dd7350a7df07214b3e02726ab67a19dc27d0489655bba7adbd14"},{"bytes":8274,"name":"publication.txt","sha256":"84271582d7681c4eefe1ae2b0f9a9b1b4818e622a62c6bf341fe7c5c84800a02"},{"bytes":2862,"name":"manifest.json","sha256":"dfe0aa486ceeaa3b2987e7a4f774caff9c2347e7558c195a124ed76f962fc965"},{"bytes":89,"name":"manifest.sig","sha256":"321fe434932b9065b6d63437837c7c82b3c76b4054089a1b23515045f5662c4c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c38ecdc538dde82864fbc7efaf3b3b16fc72504a6a6e9534b2b5dbedd94d8e64"}],"publication_id":"OT-2026-000089377"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089377
OpenTechnical

OT-2026-000089377

Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
84271582d7681c4eefe1ae2b0f9a9b1b4818e622a62c6bf341fe7c5c84800a02

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089377, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089377.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089377" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089377" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089377 Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089377 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089377 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089377 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089377", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19101, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5b14db826f3fff3aedc1d099ba9949601ccd329ca5f92eaa8b0dda951477a7d4" }, { "bytes": 8613, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "00f8cf1c9675dd7350a7df07214b3e02726ab67a19dc27d0489655bba7adbd14" }, { "bytes": 8274, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "84271582d7681c4eefe1ae2b0f9a9b1b4818e622a62c6bf341fe7c5c84800a02" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089377/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089377", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7cd3-949b-0452b2d08cc1" } ibcSnzS0ZUIuhl7lqV6yGHC30HnSO8SS6ePrewMVH6fW+5roVDaV3X7/2XO7derlbS7DqFAu/QPPguoEgwZ7DA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ibcSnzS0ZUIuhl7lqV6yGHC30HnSO8SS6ePrewMVH6fW+5roVDaV3X7/2XO7derlbS7DqFAu/QPPguoEgwZ7DA== {"files":[{"bytes":18848,"name":"index.html","sha256":"42c3b7460bc04551a071746cbc7aea7a02364531676a6939f92ddf50f8c6ceca"},{"bytes":8403,"name":"publication.md","sha256":"df75e64b9e7d2501a8b54d1066d51a658df098b8b11e3cd17aa6298138b68f1c"},{"bytes":8064,"name":"publication.txt","sha256":"8402591aa6938ee95c3e3d30e58e31b6e9532c00134fe8f6c2696a565c5cd739"},{"bytes":2862,"name":"manifest.json","sha256":"5f1dd1282f035b87f0211e9712b803f3e14c64c0965160237d6921d39c68801c"},{"bytes":89,"name":"manifest.sig","sha256":"64ea21c82aeee3ce59b1357c0ed6b6f0271af9314a944ea4979125118c2f433a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ba829f592ec9256dcdb7a3d2584e21123326850cd60c97671436f0e8ff9f6568"}],"publication_id":"OT-2026-000089378"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089378
OpenTechnical

OT-2026-000089378

Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8402591aa6938ee95c3e3d30e58e31b6e9532c00134fe8f6c2696a565c5cd739

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089378, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089378.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089378" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089378" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089378 Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089378 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089378 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089378 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089378", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18848, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "42c3b7460bc04551a071746cbc7aea7a02364531676a6939f92ddf50f8c6ceca" }, { "bytes": 8403, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "df75e64b9e7d2501a8b54d1066d51a658df098b8b11e3cd17aa6298138b68f1c" }, { "bytes": 8064, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8402591aa6938ee95c3e3d30e58e31b6e9532c00134fe8f6c2696a565c5cd739" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089378/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089378", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7ae7-8938-1ece5f5d2751" } pLQr5T81TZ8XVeoYfNLhUSUWL146fad6Pr4JA1rvoeUKpVBmnftniQEw/EyFRlIzNzgt1SWfgiZnQ6lP7e1ZCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: pLQr5T81TZ8XVeoYfNLhUSUWL146fad6Pr4JA1rvoeUKpVBmnftniQEw/EyFRlIzNzgt1SWfgiZnQ6lP7e1ZCQ== {"files":[{"bytes":18287,"name":"index.html","sha256":"ee911038b009bdf8bcf851e6563b3f8fcbeedfd866c85bc81832fe8acc9ad2f5"},{"bytes":7913,"name":"publication.md","sha256":"47e758913d367db8187cc7608d64c8d59f1f9fd782a53eca2ee29c1c247f610e"},{"bytes":7580,"name":"publication.txt","sha256":"77e35dc80912dc80ba758bdf4666efb807f08771554e6ad913dbe0e07ce7ba79"},{"bytes":2850,"name":"manifest.json","sha256":"9670a0cee981d53e3a981396bac86f23499624d3290a7a013a4ba243533d423c"},{"bytes":89,"name":"manifest.sig","sha256":"0e3b7865256d9bc548398b623213a5ea8554021ed0d9450d5d42ee2ca7adaecc"},{"bytes":227,"name":"manifest.sig.txt","sha256":"892869aa41401df0f4248ad77405c82c642677a384799d0f6a1b56c0776ae1a3"}],"publication_id":"OT-2026-000089379"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089379
OpenTechnical

OT-2026-000089379

Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
77e35dc80912dc80ba758bdf4666efb807f08771554e6ad913dbe0e07ce7ba79

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089379, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089379.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089379" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089379" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089379 Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089379 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089379 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089379 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089379", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18287, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ee911038b009bdf8bcf851e6563b3f8fcbeedfd866c85bc81832fe8acc9ad2f5" }, { "bytes": 7913, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "47e758913d367db8187cc7608d64c8d59f1f9fd782a53eca2ee29c1c247f610e" }, { "bytes": 7580, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "77e35dc80912dc80ba758bdf4666efb807f08771554e6ad913dbe0e07ce7ba79" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089379/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089379", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7220-b204-9d06afbe68e6" } 8tFqz4cs535q9tDkXgBzSy4WSznr+2dZgHAWEARc88uiL6SpznSy9AgE+mjKmBgDL1vBhl5G/BV8o+0JdqoQBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 8tFqz4cs535q9tDkXgBzSy4WSznr+2dZgHAWEARc88uiL6SpznSy9AgE+mjKmBgDL1vBhl5G/BV8o+0JdqoQBg== {"files":[{"bytes":19102,"name":"index.html","sha256":"13da29f46b7d76b39890c85bf03475c621615669d6e9e8d6078cbd0aab20f747"},{"bytes":8614,"name":"publication.md","sha256":"061932be1d4ee0c75f5cdb8f93aad732283da9e59613d0532c610dcdcb7a0586"},{"bytes":8275,"name":"publication.txt","sha256":"2ef0d57e11a7a45c28169750435946a7d89b6da873ef50ca72b2d6ce351fc9e7"},{"bytes":2862,"name":"manifest.json","sha256":"fe1ead528eac5d75c624d35e72473fb1b3878929accb66217e8496b4b168e765"},{"bytes":89,"name":"manifest.sig","sha256":"98a8139d29c71e5ca9a359d1b723c36e6f374f4bf8077a005061a94292ff09df"},{"bytes":227,"name":"manifest.sig.txt","sha256":"35592127f28105779f644244574b0b17edc4a3f6ed36b8090de1388ba80193d8"}],"publication_id":"OT-2026-000089380"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089380
OpenTechnical

OT-2026-000089380

Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
2ef0d57e11a7a45c28169750435946a7d89b6da873ef50ca72b2d6ce351fc9e7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089380, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089380.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089380" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089380" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089380 Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089380 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089380 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089380 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089380", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19102, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "13da29f46b7d76b39890c85bf03475c621615669d6e9e8d6078cbd0aab20f747" }, { "bytes": 8614, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "061932be1d4ee0c75f5cdb8f93aad732283da9e59613d0532c610dcdcb7a0586" }, { "bytes": 8275, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2ef0d57e11a7a45c28169750435946a7d89b6da873ef50ca72b2d6ce351fc9e7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089380/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089380", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-751f-a257-9db386fba8e3" } QkLeZS+5+845KkbpQyEKQebzAOSM61Y7V+ZvohyNsh85uttvigGThwhz0dw5w7TcgRnNf+rxZQHSoiquY8z9AA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: QkLeZS+5+845KkbpQyEKQebzAOSM61Y7V+ZvohyNsh85uttvigGThwhz0dw5w7TcgRnNf+rxZQHSoiquY8z9AA== {"files":[{"bytes":18849,"name":"index.html","sha256":"6d7e5f39e4198f5f84e269c316e9dd1deb7f6ad9b240088e65fa93583210b740"},{"bytes":8404,"name":"publication.md","sha256":"aaac1403edfd6c2c4bb6de64060623b277025214ca1e73434c8fffa6fe43988b"},{"bytes":8065,"name":"publication.txt","sha256":"3669d81804a736b9b9ed0217e40b5fa74235fd96d7a2fd9b7e8e3a8b0722c3f2"},{"bytes":2862,"name":"manifest.json","sha256":"c193410444e8c8ea41e99cdef69385f37c4639e48754afce4d4c343a2d290ba8"},{"bytes":89,"name":"manifest.sig","sha256":"1cb47f326e57aa167c5a143a987359dcd980b3c5292f8bf0d91b8582f69816b4"},{"bytes":227,"name":"manifest.sig.txt","sha256":"982d5a56d9e3ce4af0e62de36b10a38f8d1278a8aa6d1b113b36a50ea43e0d98"}],"publication_id":"OT-2026-000089381"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089381
OpenTechnical

OT-2026-000089381

Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
3669d81804a736b9b9ed0217e40b5fa74235fd96d7a2fd9b7e8e3a8b0722c3f2

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089381, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089381.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089381" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089381" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089381 Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089381 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089381 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089381 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089381", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18849, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6d7e5f39e4198f5f84e269c316e9dd1deb7f6ad9b240088e65fa93583210b740" }, { "bytes": 8404, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "aaac1403edfd6c2c4bb6de64060623b277025214ca1e73434c8fffa6fe43988b" }, { "bytes": 8065, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3669d81804a736b9b9ed0217e40b5fa74235fd96d7a2fd9b7e8e3a8b0722c3f2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089381/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089381", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7ece-be06-2987f110df72" } AOSDG3sIamJRAeZOsk5AHYznH3/2oYQ2yecC0gwIhn76hwNFcPspAVrwWR3kwv8gMH3PBUiCKEzzfQl7Z+x1BA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: AOSDG3sIamJRAeZOsk5AHYznH3/2oYQ2yecC0gwIhn76hwNFcPspAVrwWR3kwv8gMH3PBUiCKEzzfQl7Z+x1BA== {"files":[{"bytes":18291,"name":"index.html","sha256":"d10de3c70a6b30e88494b77039c58fa18801277e64858a722919943fa134c1af"},{"bytes":7917,"name":"publication.md","sha256":"3098445dac3318224407e49d617554a90fb11e1ec49541cb752cfa3c3969f404"},{"bytes":7584,"name":"publication.txt","sha256":"b03e4e2478717ec4a07304fc0fb9ad00556b83ce722119d32afef7c1ef2df677"},{"bytes":2850,"name":"manifest.json","sha256":"8ceeaa1d0232bc1a149ba415aec4e82cac5e9c73f938004a7f6eac6bd740d437"},{"bytes":89,"name":"manifest.sig","sha256":"68d7147ca384e85d6a1ac1f6eb0ffa544dfe65d9f3a10249b115bc3171e8a53e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"79ee3479b087d62662e19cb5917d8f63ad66e4faf8e1189468502ba48b2dc9dd"}],"publication_id":"OT-2026-000089382"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089382
OpenTechnical

OT-2026-000089382

Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
b03e4e2478717ec4a07304fc0fb9ad00556b83ce722119d32afef7c1ef2df677

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089382, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089382.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089382" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089382" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089382 Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089382 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089382 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089382 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089382", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18291, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d10de3c70a6b30e88494b77039c58fa18801277e64858a722919943fa134c1af" }, { "bytes": 7917, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3098445dac3318224407e49d617554a90fb11e1ec49541cb752cfa3c3969f404" }, { "bytes": 7584, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b03e4e2478717ec4a07304fc0fb9ad00556b83ce722119d32afef7c1ef2df677" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089382/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089382", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7a5c-b297-6687cec305ae" } DfouQ56PtKr5YYP8CRLXN8/7Wh9PgG5k6JT8Am6buYfOpEUmKl12bm1fVV5ulF2lnet2mx4uVqwuHs1LGveWBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: DfouQ56PtKr5YYP8CRLXN8/7Wh9PgG5k6JT8Am6buYfOpEUmKl12bm1fVV5ulF2lnet2mx4uVqwuHs1LGveWBQ== {"files":[{"bytes":19106,"name":"index.html","sha256":"2392fa3ee1213661ab672ba538101f50fd17cf046f94735dcb23b64610cec37c"},{"bytes":8618,"name":"publication.md","sha256":"8fa745fe551319b09cc0f1828c67ebe739b02e75439c4b35739f39943dd9f8a4"},{"bytes":8279,"name":"publication.txt","sha256":"85f25d237f1f15f02ab8a4845ea94b05a89053f5616f93e6cc10b757d554d34a"},{"bytes":2862,"name":"manifest.json","sha256":"4b164c974b105c334bb1d7d8d2b132917737a419dcc1f9957c445dcdeed59b14"},{"bytes":89,"name":"manifest.sig","sha256":"9fc110dd47a32931dec1d15381eb1ba5bb19d84e1ff390afa689b2a5348f8a9e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"35305f693fed4cb14501e29eb7eeb35ae9d8ece91e69a9a96e5e158a840e63b1"}],"publication_id":"OT-2026-000089383"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089383
OpenTechnical

OT-2026-000089383

Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
85f25d237f1f15f02ab8a4845ea94b05a89053f5616f93e6cc10b757d554d34a

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089383, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089383.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089383" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089383" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089383 Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089383 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089383 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089383 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089383", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19106, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2392fa3ee1213661ab672ba538101f50fd17cf046f94735dcb23b64610cec37c" }, { "bytes": 8618, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8fa745fe551319b09cc0f1828c67ebe739b02e75439c4b35739f39943dd9f8a4" }, { "bytes": 8279, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "85f25d237f1f15f02ab8a4845ea94b05a89053f5616f93e6cc10b757d554d34a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089383/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089383", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7a40-8f39-8d6dbc2b2da3" } UUZAtqthcge/I55u2v+0zSnAImVguYYSTd28b4rldk+iMaI7Cy7Bp8+z4E3SifMpJK7YzSZr3+ERIgTx1DmZDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: UUZAtqthcge/I55u2v+0zSnAImVguYYSTd28b4rldk+iMaI7Cy7Bp8+z4E3SifMpJK7YzSZr3+ERIgTx1DmZDw== {"files":[{"bytes":18853,"name":"index.html","sha256":"d5ef2efba12762fe93a6fa2627496f3b24a8c2f7012b232dc0a3378af11cf770"},{"bytes":8408,"name":"publication.md","sha256":"2a7b10c31f7374fdf19719382b470781ffa2d4eccb81fbdbde1a258e9bc1c032"},{"bytes":8069,"name":"publication.txt","sha256":"e692cdd62bab13ef4fa628ee3639fda97d86bbf1a8fcb3a9a3a295f7713e74b2"},{"bytes":2862,"name":"manifest.json","sha256":"474f9a57fc1395b4153b9aaa4abe95111256c4beff8e473d507f3d73701eee72"},{"bytes":89,"name":"manifest.sig","sha256":"9c35f78f4f5be3e32195e4182288887322b50c28b01612bd4375c85c052d0419"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e7ebcfbd07a5eea577d04d67b232fdb2e8e12b50ac0f2924bc8f60de39bc96bf"}],"publication_id":"OT-2026-000089384"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089384
OpenTechnical

OT-2026-000089384

Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e692cdd62bab13ef4fa628ee3639fda97d86bbf1a8fcb3a9a3a295f7713e74b2

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089384, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089384.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089384" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089384" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089384 Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089384 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089384 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089384 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089384", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18853, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d5ef2efba12762fe93a6fa2627496f3b24a8c2f7012b232dc0a3378af11cf770" }, { "bytes": 8408, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "2a7b10c31f7374fdf19719382b470781ffa2d4eccb81fbdbde1a258e9bc1c032" }, { "bytes": 8069, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e692cdd62bab13ef4fa628ee3639fda97d86bbf1a8fcb3a9a3a295f7713e74b2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089384/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089384", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7e05-8968-379ecc080f76" } cFqFjIL6Q+3VayUcq0PPQ5PEKoOqL3JxikSjJWwoAu8n7SEI71SUWZFU1cDSiVevwH8+vIBTjoyhGkDmM6maDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: cFqFjIL6Q+3VayUcq0PPQ5PEKoOqL3JxikSjJWwoAu8n7SEI71SUWZFU1cDSiVevwH8+vIBTjoyhGkDmM6maDA== {"files":[{"bytes":18480,"name":"index.html","sha256":"170c6f92dddb26db51b919a0d63947ba6de5c15a17375c1d26fc0658bcfb176e"},{"bytes":8074,"name":"publication.md","sha256":"6105ed2d8ef0e0650270eba711220053e58c9903c0cccb3c79d5ed80296763b4"},{"bytes":7751,"name":"publication.txt","sha256":"f11ebb6c82669a740a18dcdb7feb2fe077b6bead3338895dc7c66eafb3f1322a"},{"bytes":2829,"name":"manifest.json","sha256":"972b92fb7ff4145a584571d801b04cc6f9d022d6c0c56ec09b74bab90ae8880a"},{"bytes":89,"name":"manifest.sig","sha256":"3a59dada38e883301ad08a1b5c10cd8e8c5af685528b72a3d0bf3004d2468f79"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7bef136b4a0efafaa1bac6639b74ed9cae7b2ae1f154a9a30143fe7c339c41e1"}],"publication_id":"OT-2026-000089385"} Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089385
OpenTechnical

OT-2026-000089385

Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
f11ebb6c82669a740a18dcdb7feb2fe077b6bead3338895dc7c66eafb3f1322a

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089385, “Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089385.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089385" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089385" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089385 Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089385 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089385 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089385 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089385", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1131 }, "figures": [], "files": [ { "bytes": 18480, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "170c6f92dddb26db51b919a0d63947ba6de5c15a17375c1d26fc0658bcfb176e" }, { "bytes": 8074, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "6105ed2d8ef0e0650270eba711220053e58c9903c0cccb3c79d5ed80296763b4" }, { "bytes": 7751, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f11ebb6c82669a740a18dcdb7feb2fe077b6bead3338895dc7c66eafb3f1322a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089385/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089385", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7a9f-8d5e-17bccce102d6" } 2lSNt3Vs6ACYpqaT1zgwXedcMpBhJUPi43V/xJRKamQn4wvqC9Dg/jBuzkvtm5eDhxJ+hm0VEUgVchuNL/aYCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 2lSNt3Vs6ACYpqaT1zgwXedcMpBhJUPi43V/xJRKamQn4wvqC9Dg/jBuzkvtm5eDhxJ+hm0VEUgVchuNL/aYCg== {"files":[{"bytes":19295,"name":"index.html","sha256":"42f036f84fdf0a19ae5b67bdcf2de16382a9335daa458cf3c628a1c20384b0bc"},{"bytes":8775,"name":"publication.md","sha256":"ee72944080c21b9746495de9b429859d5f8363f76f75e522b856c8c724321781"},{"bytes":8446,"name":"publication.txt","sha256":"408af31f9cde8fe2d9ccf5d7b96f3ba35e68c4f0b58623e4b385caf05a8b9486"},{"bytes":2841,"name":"manifest.json","sha256":"179129e0450c251216b7495eab8c4a104051cbb1a8105bdaf275b32610fdfb56"},{"bytes":89,"name":"manifest.sig","sha256":"6bf1423a4070619663850121b3280cf50ebab3bbb4f6b570e976c167d0d49725"},{"bytes":227,"name":"manifest.sig.txt","sha256":"43657f282c46dd0a979785058c0ad83093e1c424b3b26b0c58c3dca2660513c0"}],"publication_id":"OT-2026-000089386"} Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089386
OpenTechnical

OT-2026-000089386

Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
408af31f9cde8fe2d9ccf5d7b96f3ba35e68c4f0b58623e4b385caf05a8b9486

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089386, “Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089386.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089386" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089386" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089386 Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089386 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089386 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089386 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089386", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1237 }, "figures": [], "files": [ { "bytes": 19295, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "42f036f84fdf0a19ae5b67bdcf2de16382a9335daa458cf3c628a1c20384b0bc" }, { "bytes": 8775, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ee72944080c21b9746495de9b429859d5f8363f76f75e522b856c8c724321781" }, { "bytes": 8446, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "408af31f9cde8fe2d9ccf5d7b96f3ba35e68c4f0b58623e4b385caf05a8b9486" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089386/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089386", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7ed1-916f-b931f3ad9bda" } Xe+TbbUBLcswAUvsYLiLrewR1biEaoteSJ8dg1WBqM1MXi12HyozcZPMd3CRbH1GVqhQfakbTSkYgO6TLNyuCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Xe+TbbUBLcswAUvsYLiLrewR1biEaoteSJ8dg1WBqM1MXi12HyozcZPMd3CRbH1GVqhQfakbTSkYgO6TLNyuCQ== {"files":[{"bytes":19042,"name":"index.html","sha256":"5d05942ea8e08f05f2a6c0b6b1617fa0aa705cfe783dbdd073575a42e739c5e1"},{"bytes":8565,"name":"publication.md","sha256":"0c86884ef9b6f99ed4ca6460dc470ef3b4edfe9eef2b3616fe34b1ce57948b3e"},{"bytes":8236,"name":"publication.txt","sha256":"98ec08d74211776c828cd57073117dafe969bb7121746ade553d90694fcc29bd"},{"bytes":2841,"name":"manifest.json","sha256":"1462bfdc7f5487b40ea97127a45f1dc06fada6365df4130224574c6ccba34ef8"},{"bytes":89,"name":"manifest.sig","sha256":"d2c814b0b707dbd663c73d2b3412cae0d1a981d7b0b18f35fa7483a629a70ce4"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8ee9d83615750462903d3a20f650f969850783d7e4c57c735a411c4c55a9e115"}],"publication_id":"OT-2026-000089387"} Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089387
OpenTechnical

OT-2026-000089387

Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
98ec08d74211776c828cd57073117dafe969bb7121746ade553d90694fcc29bd

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089387, “Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089387.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089387" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089387" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089387 Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089387 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089387 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089387 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089387", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19042, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5d05942ea8e08f05f2a6c0b6b1617fa0aa705cfe783dbdd073575a42e739c5e1" }, { "bytes": 8565, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0c86884ef9b6f99ed4ca6460dc470ef3b4edfe9eef2b3616fe34b1ce57948b3e" }, { "bytes": 8236, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "98ec08d74211776c828cd57073117dafe969bb7121746ade553d90694fcc29bd" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089387/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089387", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7100-939f-1bea1099b39e" } ppY6q6k14W711ccS6aYLvnX2KACoMrrcdsjhh3wZVZYpds3GQikP88GaF4e2t/c/9cwtMXJNN8FOuDsyjGIYDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ppY6q6k14W711ccS6aYLvnX2KACoMrrcdsjhh3wZVZYpds3GQikP88GaF4e2t/c/9cwtMXJNN8FOuDsyjGIYDA== {"files":[{"bytes":18426,"name":"index.html","sha256":"54d278fd2289ae2aa7b6647764a44ad099a87aac16db449cb4d1a9acded43aac"},{"bytes":8020,"name":"publication.md","sha256":"f130f40e173d706a133cec9bfb2c77952fa30e2ae7f8dc4981853ea5e2562c84"},{"bytes":7697,"name":"publication.txt","sha256":"3aede7f74b93dfad174e9769409586063cfcbc2dadbcf31b3463da73156b4c5c"},{"bytes":2829,"name":"manifest.json","sha256":"8b397b247dc1730086d589162bc381577b0e4cd945bccd90d06825f73cfa46b8"},{"bytes":89,"name":"manifest.sig","sha256":"6f83e722d74f2df4a4b2149342d4e87bf05dadf92df9e2937e7feb4107a13ae1"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c422a8ea06653cbb03e9149c5e4e98763439123aee27c43834a3c697cf5b8112"}],"publication_id":"OT-2026-000089388"} Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089388
OpenTechnical

OT-2026-000089388

Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
3aede7f74b93dfad174e9769409586063cfcbc2dadbcf31b3463da73156b4c5c

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089388, “Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089388.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089388" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089388" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089388 Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089388 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089388 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089388 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089388", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1116 }, "figures": [], "files": [ { "bytes": 18426, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "54d278fd2289ae2aa7b6647764a44ad099a87aac16db449cb4d1a9acded43aac" }, { "bytes": 8020, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f130f40e173d706a133cec9bfb2c77952fa30e2ae7f8dc4981853ea5e2562c84" }, { "bytes": 7697, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3aede7f74b93dfad174e9769409586063cfcbc2dadbcf31b3463da73156b4c5c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089388/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089388", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7e1f-9192-4c3bbd01192d" } 6Pxp29bCh2zRZTALmGovqPHVXHbO5KKQChwnlPuktxu16rd0kABSawojRz2EygVWo32T9uRlUG3qfXjNIpDOAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 6Pxp29bCh2zRZTALmGovqPHVXHbO5KKQChwnlPuktxu16rd0kABSawojRz2EygVWo32T9uRlUG3qfXjNIpDOAg== {"files":[{"bytes":19241,"name":"index.html","sha256":"a6ec2dcef7c0d5af7dad880a798d91be62d20f0adb5072e48078a9836e0f07e0"},{"bytes":8721,"name":"publication.md","sha256":"72c9ce8247ebb5e0ef31aff6773aa55821369df7f79d99cdfdc702fdc7539d4d"},{"bytes":8392,"name":"publication.txt","sha256":"ae00f053aa20bbd16097feeeaab548c256e864ad8f74f69c7a74ba8a1a6920f4"},{"bytes":2841,"name":"manifest.json","sha256":"d6e062a6cda1f37c8cfb65ac89ef9d641a69476e0e94d43cea53a9638c0dec23"},{"bytes":89,"name":"manifest.sig","sha256":"036db770f2e209a9fed1736d27b2c487f66639d5c7cfa199e769b5666c41b31c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"000b0d9854075eeff215cb787ed67fbebd40a2de6f48dfd5499dad487e6a369a"}],"publication_id":"OT-2026-000089389"} Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089389
OpenTechnical

OT-2026-000089389

Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
ae00f053aa20bbd16097feeeaab548c256e864ad8f74f69c7a74ba8a1a6920f4

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089389, “Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089389.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089389" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089389" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089389 Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089389 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089389 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089389 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089389", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1222 }, "figures": [], "files": [ { "bytes": 19241, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a6ec2dcef7c0d5af7dad880a798d91be62d20f0adb5072e48078a9836e0f07e0" }, { "bytes": 8721, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "72c9ce8247ebb5e0ef31aff6773aa55821369df7f79d99cdfdc702fdc7539d4d" }, { "bytes": 8392, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ae00f053aa20bbd16097feeeaab548c256e864ad8f74f69c7a74ba8a1a6920f4" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089389/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089389", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7401-bef8-871185120ab2" } Uibr7vaIOHBGrrpJMAy1fs7D/OCu12dRUzJn4mK6juGJc7tNfcpLRGMWhTrK/RrOS/OppnimyQl5t57YXKS7AA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Uibr7vaIOHBGrrpJMAy1fs7D/OCu12dRUzJn4mK6juGJc7tNfcpLRGMWhTrK/RrOS/OppnimyQl5t57YXKS7AA== {"files":[{"bytes":18988,"name":"index.html","sha256":"fd39d601ebc1265f02e7ce9e3909b58ab9b58039edd9a5ac3e1420db34434710"},{"bytes":8511,"name":"publication.md","sha256":"dfdf4c89082f2a4aef8464344eda9bfd58b6087c434fababb097e3cbf3c05ff4"},{"bytes":8182,"name":"publication.txt","sha256":"8837d35157d7dff9e382e9f1e5ce650eef7a7b062b4fd4fe7a37c43db8195b67"},{"bytes":2841,"name":"manifest.json","sha256":"4d701a3dc975e4a8c7bd80037c5492901da8071ab1db3d2e3577e308fb1dc2e0"},{"bytes":89,"name":"manifest.sig","sha256":"75ed01c1799029abc1026ba89ea6ec9ae4d68bd0b3557e01376cf40a29c2c9bb"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ca1de2197fdac9d9b015ee70326ff2cbc05f7484a71f92f7cfd4cf172c8a3f7c"}],"publication_id":"OT-2026-000089390"} Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089390
OpenTechnical

OT-2026-000089390

Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8837d35157d7dff9e382e9f1e5ce650eef7a7b062b4fd4fe7a37c43db8195b67

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089390, “Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089390.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089390" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089390" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089390 Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089390 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089390 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089390 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089390", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1187 }, "figures": [], "files": [ { "bytes": 18988, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "fd39d601ebc1265f02e7ce9e3909b58ab9b58039edd9a5ac3e1420db34434710" }, { "bytes": 8511, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "dfdf4c89082f2a4aef8464344eda9bfd58b6087c434fababb097e3cbf3c05ff4" }, { "bytes": 8182, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8837d35157d7dff9e382e9f1e5ce650eef7a7b062b4fd4fe7a37c43db8195b67" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089390/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089390", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-78af-9123-51c73a22bab9" } EnQPZGLblRuO5GwZTknHjbah6NAX1a6TXdu5YcFcaG+kxXMw2dJ8N5h7d3UtCw183Y/uJjbNxijC2kKdhmEHDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: EnQPZGLblRuO5GwZTknHjbah6NAX1a6TXdu5YcFcaG+kxXMw2dJ8N5h7d3UtCw183Y/uJjbNxijC2kKdhmEHDA== {"files":[{"bytes":18180,"name":"index.html","sha256":"d40087153e2f03a42c21b51487d68628d2c74662f6d69f06e7214490479b5f94"},{"bytes":7822,"name":"publication.md","sha256":"8398a8944d4eb2770b7f1335332a662db81ce40376ad2217f431f9421648b843"},{"bytes":7497,"name":"publication.txt","sha256":"fa48f11b08c9114c939e27f3e91517b0864807010343c32523b0122f00fbb255"},{"bytes":2842,"name":"manifest.json","sha256":"cb7c6618e64dbaf511539d60cbb86913246812f2a5816d3a0d5c403e4785ad85"},{"bytes":89,"name":"manifest.sig","sha256":"425f281a0136d00d4fa0f030d46f62ec2e1cd1660170675d3c203f0f8d35fbbd"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ad60c8739dd1eba54f90a08763e517e496fa808ade2fa8b3c0047847b969d879"}],"publication_id":"OT-2026-000089391"} Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089391
OpenTechnical

OT-2026-000089391

Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
fa48f11b08c9114c939e27f3e91517b0864807010343c32523b0122f00fbb255

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089391, “Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089391.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089391" title: "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089391" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089391 Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089391 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089391 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089391 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089391", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1079 }, "figures": [], "files": [ { "bytes": 18180, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d40087153e2f03a42c21b51487d68628d2c74662f6d69f06e7214490479b5f94" }, { "bytes": 7822, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8398a8944d4eb2770b7f1335332a662db81ce40376ad2217f431f9421648b843" }, { "bytes": 7497, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fa48f11b08c9114c939e27f3e91517b0864807010343c32523b0122f00fbb255" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089391/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089391", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-71b1-b34a-ac9ec80bdf0e" } qsLGytYQDqpTuCZsNCZas6/D5AM0o7dhxZmrDjEcUiDZtw/ibSJ9/y74z276W1RpaZMhNBpZER+9K4sV7qwTCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: qsLGytYQDqpTuCZsNCZas6/D5AM0o7dhxZmrDjEcUiDZtw/ibSJ9/y74z276W1RpaZMhNBpZER+9K4sV7qwTCA== {"files":[{"bytes":18995,"name":"index.html","sha256":"f59f0422fd92ec11ab3fd6a1f24dc76f0e8b96def8f61651595bf7935636ee35"},{"bytes":8523,"name":"publication.md","sha256":"430bb4ede64ef01aac41a0718b1539ba7b5d54ebb64f098bdd0fee1f947fd5ad"},{"bytes":8192,"name":"publication.txt","sha256":"64da08bd7d89a96b7231897df257a0856356c041953c7cefbe43c5203b750b2d"},{"bytes":2854,"name":"manifest.json","sha256":"a1d3441fa14319ff8f408bbb934e2541598e3276a19c0ac6b2be3fdd73d9a96c"},{"bytes":89,"name":"manifest.sig","sha256":"afb6d29598808c79ed53db746d0f13d140d44b733510b0542915f3b6af2e7d06"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b933ec91ec4bb0a51f5985672b4b9d83892a7e29da34919007dfbc0e9d948c2c"}],"publication_id":"OT-2026-000089392"} Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089392
OpenTechnical

OT-2026-000089392

Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
64da08bd7d89a96b7231897df257a0856356c041953c7cefbe43c5203b750b2d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089392, “Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089392.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089392" title: "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089392" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089392 Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089392 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089392 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089392 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089392", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1185 }, "figures": [], "files": [ { "bytes": 18995, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f59f0422fd92ec11ab3fd6a1f24dc76f0e8b96def8f61651595bf7935636ee35" }, { "bytes": 8523, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "430bb4ede64ef01aac41a0718b1539ba7b5d54ebb64f098bdd0fee1f947fd5ad" }, { "bytes": 8192, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "64da08bd7d89a96b7231897df257a0856356c041953c7cefbe43c5203b750b2d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089392/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089392", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-730b-98a2-5c9ab3a3126f" } eABS9KEvZ1J1QpvIjIJvnogfGUPXoyDlTf2mk+0rxZrUJfCirOX7dYtfYZCRGFdJEdR7RssocSukZFjUzq1HBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: eABS9KEvZ1J1QpvIjIJvnogfGUPXoyDlTf2mk+0rxZrUJfCirOX7dYtfYZCRGFdJEdR7RssocSukZFjUzq1HBQ== {"files":[{"bytes":18742,"name":"index.html","sha256":"c71b960640874a39369b8e7de15be4b89125f1c8123650126450b1cb122c019a"},{"bytes":8313,"name":"publication.md","sha256":"cb36b701835b29dafc9507a82e2b7cde7b2ebc445432743f813e7af8ed65e8db"},{"bytes":7982,"name":"publication.txt","sha256":"4aaf1800ba6e6af7d91f7691251a2c22c3468bde639bcfd603b2f98334426adb"},{"bytes":2854,"name":"manifest.json","sha256":"4c04b5073ad1d6c21aeb78ec6fb2b331aa208408f3ce504bbddcfe45235fc8f0"},{"bytes":89,"name":"manifest.sig","sha256":"20db04ae59e7a9626999a14419a0d009c6a296e875c4a6acba64192f9c8936f2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"bf4bf3a14349d91a3f1c1ef5c71a3fcecaa16f222128838d83f481e74514f088"}],"publication_id":"OT-2026-000089393"} Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089393
OpenTechnical

OT-2026-000089393

Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
4aaf1800ba6e6af7d91f7691251a2c22c3468bde639bcfd603b2f98334426adb

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089393, “Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089393.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089393" title: "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089393" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089393 Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089393 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089393 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089393 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089393", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1150 }, "figures": [], "files": [ { "bytes": 18742, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c71b960640874a39369b8e7de15be4b89125f1c8123650126450b1cb122c019a" }, { "bytes": 8313, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cb36b701835b29dafc9507a82e2b7cde7b2ebc445432743f813e7af8ed65e8db" }, { "bytes": 7982, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4aaf1800ba6e6af7d91f7691251a2c22c3468bde639bcfd603b2f98334426adb" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089393/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089393", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7a95-9951-4cb0d54f8783" } oej0+UqJegOHRgR7Yf8xvUcZmxof6zFubMf45rAYVJhfOZNXg3YEEHRVd/n+DgxtQ/AXJLj6G9V1mkQIlJDRBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: oej0+UqJegOHRgR7Yf8xvUcZmxof6zFubMf45rAYVJhfOZNXg3YEEHRVd/n+DgxtQ/AXJLj6G9V1mkQIlJDRBw== {"files":[{"bytes":18180,"name":"index.html","sha256":"92e55ca5170fcc68f612c30cfd7ce5392aae0026b72a18cafbf5730950aff89b"},{"bytes":7822,"name":"publication.md","sha256":"57b7b713b14f92776feb56d4293a577b3e2ecedca801b445b0b7f918dedade8b"},{"bytes":7497,"name":"publication.txt","sha256":"ac68effe61b0e0e63f3760eaadf4008485e486174a9fb3e0a991a0f510ad9405"},{"bytes":2842,"name":"manifest.json","sha256":"41f93b8cb0d0bfdbc5cae54faf320a0acf3c6075e2449c830fe988f00453e126"},{"bytes":89,"name":"manifest.sig","sha256":"72d879feceec636ff51856bf48eab6a220006b0ef23bedd8147bcf75e650be74"},{"bytes":227,"name":"manifest.sig.txt","sha256":"6d31eb0aef7b45c6e165ed56def09678846a0105385db31fd7f17e0a46a5f33b"}],"publication_id":"OT-2026-000089394"} Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089394
OpenTechnical

OT-2026-000089394

Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
ac68effe61b0e0e63f3760eaadf4008485e486174a9fb3e0a991a0f510ad9405

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089394, “Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089394.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089394" title: "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089394" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089394 Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089394 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089394 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089394 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089394", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1079 }, "figures": [], "files": [ { "bytes": 18180, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "92e55ca5170fcc68f612c30cfd7ce5392aae0026b72a18cafbf5730950aff89b" }, { "bytes": 7822, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "57b7b713b14f92776feb56d4293a577b3e2ecedca801b445b0b7f918dedade8b" }, { "bytes": 7497, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ac68effe61b0e0e63f3760eaadf4008485e486174a9fb3e0a991a0f510ad9405" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089394/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089394", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-740d-98a8-6d462a386df7" } ZNrlKli+TYIpTwkApF7fK8QcHrt8hKBI2MhrAHXBk1YRcLJM9lkBzmcHsc4HzHz0NDugB1EnXH76B1wILFVSBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ZNrlKli+TYIpTwkApF7fK8QcHrt8hKBI2MhrAHXBk1YRcLJM9lkBzmcHsc4HzHz0NDugB1EnXH76B1wILFVSBQ== {"files":[{"bytes":18995,"name":"index.html","sha256":"cc2b56e7bcdf939eea7020dea767ab9253b98259160a0acddfc3e1330525a824"},{"bytes":8523,"name":"publication.md","sha256":"fcd7fbe596f6541e646dca1a9ba0664c695e4bdd7f6b506d82fbdc47f668f0a8"},{"bytes":8192,"name":"publication.txt","sha256":"e7c0eba3dce2305524040be9b6605726017b7055fca1f02bb33783a7df9f3031"},{"bytes":2854,"name":"manifest.json","sha256":"8b3f83c1f97b42c2e12c373f859bbc9488e942b9cf17412927319e66cdcb22e9"},{"bytes":89,"name":"manifest.sig","sha256":"92cc18c106393a63d1271759593b61bf0930a9c9647070e70a54501542856679"},{"bytes":227,"name":"manifest.sig.txt","sha256":"5573d8c1dcde39bc7a123113ad193b0388042b29741fc1c1829dcc7fbc271462"}],"publication_id":"OT-2026-000089395"} Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089395
OpenTechnical

OT-2026-000089395

Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e7c0eba3dce2305524040be9b6605726017b7055fca1f02bb33783a7df9f3031

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089395, “Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089395.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089395" title: "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089395" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089395 Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089395 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089395 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089395 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089395", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1185 }, "figures": [], "files": [ { "bytes": 18995, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "cc2b56e7bcdf939eea7020dea767ab9253b98259160a0acddfc3e1330525a824" }, { "bytes": 8523, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fcd7fbe596f6541e646dca1a9ba0664c695e4bdd7f6b506d82fbdc47f668f0a8" }, { "bytes": 8192, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e7c0eba3dce2305524040be9b6605726017b7055fca1f02bb33783a7df9f3031" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089395/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089395", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7f2d-9d2b-6fb6516dd6b7" } TQec8/HeXiNbxhYB/E+Vnueoo5QD6D0FikOAEsgcqO0P8uqAS99jbhG7fjwHn/Air2t8d+y28+vDJ7HXU0RHAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: TQec8/HeXiNbxhYB/E+Vnueoo5QD6D0FikOAEsgcqO0P8uqAS99jbhG7fjwHn/Air2t8d+y28+vDJ7HXU0RHAg== {"files":[{"bytes":18742,"name":"index.html","sha256":"44d56725d1cee10bf09b9d4ad7d8636bc3475be80e3ab73eb037abf6dd8bb9ab"},{"bytes":8313,"name":"publication.md","sha256":"562ae2219cfe3e44d314a0d85a9bd371524ac7487e519d183aec911440d402fb"},{"bytes":7982,"name":"publication.txt","sha256":"cadec49b95a140307717403107b85a74207c0429f8d81ba80753d2d9bd57df67"},{"bytes":2854,"name":"manifest.json","sha256":"0d38d712a05f9bf0360145b9de4f4fff6d9c9f5640bf12c9cff2a545975c7f49"},{"bytes":89,"name":"manifest.sig","sha256":"c6fa1c49aff4cd755c639ad97c27ddb32aff402c92fa4c4c07be1cb7cc553c93"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9a8bc2375f4a93b223314c6baf31ce1f30345213b74f6852bb97f19b8f90e9ba"}],"publication_id":"OT-2026-000089396"} Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089396
OpenTechnical

OT-2026-000089396

Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cadec49b95a140307717403107b85a74207c0429f8d81ba80753d2d9bd57df67

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089396, “Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089396.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089396" title: "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089396" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089396 Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089396 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089396 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089396 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089396", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1150 }, "figures": [], "files": [ { "bytes": 18742, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "44d56725d1cee10bf09b9d4ad7d8636bc3475be80e3ab73eb037abf6dd8bb9ab" }, { "bytes": 8313, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "562ae2219cfe3e44d314a0d85a9bd371524ac7487e519d183aec911440d402fb" }, { "bytes": 7982, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cadec49b95a140307717403107b85a74207c0429f8d81ba80753d2d9bd57df67" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089396/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089396", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-77da-917a-b810c4dd11e0" } MbfSfHah26Bh2jqcTCYSkCWtnCIjQtB6zxdesaIUjmUlg+AZhCCM12Ulssg3CDoqvxGgFxsSIZQsdG5y6JcyCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: MbfSfHah26Bh2jqcTCYSkCWtnCIjQtB6zxdesaIUjmUlg+AZhCCM12Ulssg3CDoqvxGgFxsSIZQsdG5y6JcyCg== {"files":[{"bytes":18298,"name":"index.html","sha256":"b1be88a583c7f97f48bc679d43eb1a114125590c464cc7ba1e962657ea92720f"},{"bytes":7920,"name":"publication.md","sha256":"8957ccb26e19ba35a986f5418671d47080241d75cd6123ebd74935324de9ad3e"},{"bytes":7585,"name":"publication.txt","sha256":"925b66a832e5e64c6b936723365c186744c657ed27a8d383f0e70c79eca35799"},{"bytes":2852,"name":"manifest.json","sha256":"afcdf31ca8a2875cb07615bb24026cfc73d62b07322cff68760efe8966f23ca7"},{"bytes":89,"name":"manifest.sig","sha256":"d5c2b21a31428bf8d52b7177facf5c3de19f00f891185875f11584217313eb92"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f92d2cf74eaf6ce399f787221b43ddfdcbb05426fccfa589f41df7779f522765"}],"publication_id":"OT-2026-000089397"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089397
OpenTechnical

OT-2026-000089397

Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
925b66a832e5e64c6b936723365c186744c657ed27a8d383f0e70c79eca35799

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089397, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089397.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089397" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089397" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089397 Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089397 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089397 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089397 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089397", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18298, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b1be88a583c7f97f48bc679d43eb1a114125590c464cc7ba1e962657ea92720f" }, { "bytes": 7920, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8957ccb26e19ba35a986f5418671d47080241d75cd6123ebd74935324de9ad3e" }, { "bytes": 7585, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "925b66a832e5e64c6b936723365c186744c657ed27a8d383f0e70c79eca35799" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089397/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089397", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7f82-b909-6a42e89bde52" } IJ0dpHu2VzP40Gxz96gKXMlZoKL/wGzk3LffBXTevEdsRp2nsmc7oByEH3mVC389AxtZvyC1Wr1hUHoDDnRNCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: IJ0dpHu2VzP40Gxz96gKXMlZoKL/wGzk3LffBXTevEdsRp2nsmc7oByEH3mVC389AxtZvyC1Wr1hUHoDDnRNCw== {"files":[{"bytes":19113,"name":"index.html","sha256":"d88268ae2927c116ca38e06a6bf9559637ffe44c20fe9b85e61b5a617ac1999c"},{"bytes":8621,"name":"publication.md","sha256":"a7b8a759aaa6cc30f8398425ffc0b389ad0cc45fc633f45b4d27acbbcfad80f2"},{"bytes":8280,"name":"publication.txt","sha256":"82dd26009fb4135f9d1d369a4672d710fa65ef527c5c5d84504df3262e3ebe34"},{"bytes":2864,"name":"manifest.json","sha256":"bcc5a5eec9acc1ad36f33e94dad8c48cc60c0b0a11902310edbb2677d2af2c84"},{"bytes":89,"name":"manifest.sig","sha256":"12cb6db0452f1c263acbcd3cb4df7bc9ac788ddba477ccdbdb8866d14a9d4389"},{"bytes":227,"name":"manifest.sig.txt","sha256":"03b07d02ef36eb5e46d6f565ced6ce46aa7e2325d95768a5b89d76bd9ebcabc1"}],"publication_id":"OT-2026-000089398"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089398
OpenTechnical

OT-2026-000089398

Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
82dd26009fb4135f9d1d369a4672d710fa65ef527c5c5d84504df3262e3ebe34

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089398, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089398.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089398" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089398" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089398 Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089398 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089398 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089398 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089398", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19113, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d88268ae2927c116ca38e06a6bf9559637ffe44c20fe9b85e61b5a617ac1999c" }, { "bytes": 8621, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a7b8a759aaa6cc30f8398425ffc0b389ad0cc45fc633f45b4d27acbbcfad80f2" }, { "bytes": 8280, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "82dd26009fb4135f9d1d369a4672d710fa65ef527c5c5d84504df3262e3ebe34" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089398/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089398", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-779a-9b5c-718c2cb22a94" } 04/J0rMxoANWkf66wkfAcFKAoLDW2LtxNjGCvm0RLj8jbAfLbtW98csdkqRICy/kzSK6DEMp1jLbeDC2Cw5uBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 04/J0rMxoANWkf66wkfAcFKAoLDW2LtxNjGCvm0RLj8jbAfLbtW98csdkqRICy/kzSK6DEMp1jLbeDC2Cw5uBg== {"files":[{"bytes":18860,"name":"index.html","sha256":"b264a223812abb6aee7a25bf89f8c9db8fb46a097939fd437e28c61e63bea1cf"},{"bytes":8411,"name":"publication.md","sha256":"c0d1ec8727f493ffb2997b11db2a0b1d78d51bf6c5095278b9b3099f397ede2c"},{"bytes":8070,"name":"publication.txt","sha256":"cefbfb86695b7c5b243a70225a6fd2373407a1c62fb881863ee5e0b444f4889d"},{"bytes":2864,"name":"manifest.json","sha256":"de26ea5b3b4ee1aca48b9c5697f746db7a63d2ccb007f3889db8907ce3be9c12"},{"bytes":89,"name":"manifest.sig","sha256":"0c0dd762228d51d8845007444a4630f2958bc0a562e7c99634528f412adb2a5a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4ff216b9e512020a63384f62c294d1956f620e7da330015df9c13c7aef30cc88"}],"publication_id":"OT-2026-000089399"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089399
OpenTechnical

OT-2026-000089399

Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cefbfb86695b7c5b243a70225a6fd2373407a1c62fb881863ee5e0b444f4889d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089399, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089399.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089399" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089399" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089399 Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089399 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089399 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089399 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089399", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18860, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b264a223812abb6aee7a25bf89f8c9db8fb46a097939fd437e28c61e63bea1cf" }, { "bytes": 8411, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c0d1ec8727f493ffb2997b11db2a0b1d78d51bf6c5095278b9b3099f397ede2c" }, { "bytes": 8070, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cefbfb86695b7c5b243a70225a6fd2373407a1c62fb881863ee5e0b444f4889d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089399/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089399", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-75b9-9ead-0a6650ff3588" } 5LIFQpZPAGyXq/yz1U7Yat8+EOGJF4xXpAa0De6XlH9s6WEWXM2RzrNFFuFHxraC5TcKuCgDtLqk6BbL2IHaAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 5LIFQpZPAGyXq/yz1U7Yat8+EOGJF4xXpAa0De6XlH9s6WEWXM2RzrNFFuFHxraC5TcKuCgDtLqk6BbL2IHaAQ== {"files":[{"bytes":18299,"name":"index.html","sha256":"e450dd38bee036e27cdbdea4cbf6e28e8f6128986402489ba96aa5af013de8ef"},{"bytes":7921,"name":"publication.md","sha256":"7ed12a1e268527f599600f10e2aa33e64f07c49cc0b0e8f490300e3e6752e41e"},{"bytes":7586,"name":"publication.txt","sha256":"72b3297a3238f7db152cafb675c6c93195b2539f3bb7f0e9fc769da5b7525900"},{"bytes":2852,"name":"manifest.json","sha256":"84e89df42d124c913c20748c1e57b07520cad4b12b68ba72158e82d20264a335"},{"bytes":89,"name":"manifest.sig","sha256":"2e4ca204d6510d44b72da082590309b873e13d0246d015b3d147a588fc9a5305"},{"bytes":227,"name":"manifest.sig.txt","sha256":"37d6d2a801d91bb297c7d004db149d8d7e052a7452da59ff35a6f4ae048f538c"}],"publication_id":"OT-2026-000089400"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089400
OpenTechnical

OT-2026-000089400

Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
72b3297a3238f7db152cafb675c6c93195b2539f3bb7f0e9fc769da5b7525900

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089400, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089400.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089400" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089400" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089400 Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089400 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089400 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089400 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089400", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18299, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "e450dd38bee036e27cdbdea4cbf6e28e8f6128986402489ba96aa5af013de8ef" }, { "bytes": 7921, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7ed12a1e268527f599600f10e2aa33e64f07c49cc0b0e8f490300e3e6752e41e" }, { "bytes": 7586, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "72b3297a3238f7db152cafb675c6c93195b2539f3bb7f0e9fc769da5b7525900" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089400/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089400", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-751c-80fe-19578356086b" } l5fqrYRyrJ69KWDV1qH0KDqfi8SzJS9aRETKymMY2g4yYZKWw8Fc0iukGRz0ef+V8VTMG3da5UesVrDEuYExCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: l5fqrYRyrJ69KWDV1qH0KDqfi8SzJS9aRETKymMY2g4yYZKWw8Fc0iukGRz0ef+V8VTMG3da5UesVrDEuYExCg== {"files":[{"bytes":19114,"name":"index.html","sha256":"091686e695ffd225f1fa84e0aedac8deafde4c78fd49db6c25a877d87a7ca4bb"},{"bytes":8622,"name":"publication.md","sha256":"e53b2a471e4898ed5e64ef58e001ca28fd01c05506b3644605d5a7efb6a59642"},{"bytes":8281,"name":"publication.txt","sha256":"63c3adccff2d1cb4f25df1129a74c1fd4786a02237ae84a3c932cd36c32e7d77"},{"bytes":2864,"name":"manifest.json","sha256":"48faf24aac4c6c91230ae9071f33f380e9fefe50cf2a05b212bdec1c18c3c705"},{"bytes":89,"name":"manifest.sig","sha256":"b463bc2d6effbf8b28a06c36a52d5a83993926effee9300d916d52f191e8f6f3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d93a77b94243b84179a784e474624e4bdad443e63aca213c73519c91dd5ef0ca"}],"publication_id":"OT-2026-000089401"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089401
OpenTechnical

OT-2026-000089401

Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
63c3adccff2d1cb4f25df1129a74c1fd4786a02237ae84a3c932cd36c32e7d77

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089401, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089401.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089401" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089401" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089401 Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089401 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089401 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089401 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089401", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19114, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "091686e695ffd225f1fa84e0aedac8deafde4c78fd49db6c25a877d87a7ca4bb" }, { "bytes": 8622, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e53b2a471e4898ed5e64ef58e001ca28fd01c05506b3644605d5a7efb6a59642" }, { "bytes": 8281, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "63c3adccff2d1cb4f25df1129a74c1fd4786a02237ae84a3c932cd36c32e7d77" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089401/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089401", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-791e-a97b-0d92e3db778a" } /BOFBoe0BoFJ9+seIjMs6dpujZObywDYdrfJw/ZvlwBzTPI6jFRrFWi0cRB/fg2omglwZtPOwqHrLZKUAc39Cw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: /BOFBoe0BoFJ9+seIjMs6dpujZObywDYdrfJw/ZvlwBzTPI6jFRrFWi0cRB/fg2omglwZtPOwqHrLZKUAc39Cw== {"files":[{"bytes":18861,"name":"index.html","sha256":"48aed402fe5f19c1a6bab9504c3a8400616d920326bf8e54a0c5fe48d67d5173"},{"bytes":8412,"name":"publication.md","sha256":"8476da26cb3a69997850987ea8e8a893b9c96b9a2ab6fdd8955e1158ad5804ed"},{"bytes":8071,"name":"publication.txt","sha256":"b20b84cb7f2a5b81642a636d83f3b6a72479ec676c1c18f40ce232c5d71699dd"},{"bytes":2864,"name":"manifest.json","sha256":"4d8d5a14f4b8dbf1326b0d61669418648f074a9b1333b7ee0b5823a1e7b0733e"},{"bytes":89,"name":"manifest.sig","sha256":"9e71f78023fd891f70aef9225fb3faa4dea3b9350dbefcd328db840f75e56aff"},{"bytes":227,"name":"manifest.sig.txt","sha256":"bacef2315f8bed2901e4628de0070775ab36456616fb5af1c95a8252ca50392d"}],"publication_id":"OT-2026-000089402"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089402
OpenTechnical

OT-2026-000089402

Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
b20b84cb7f2a5b81642a636d83f3b6a72479ec676c1c18f40ce232c5d71699dd

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089402, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089402.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089402" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089402" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089402 Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089402 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089402 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089402 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089402", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18861, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "48aed402fe5f19c1a6bab9504c3a8400616d920326bf8e54a0c5fe48d67d5173" }, { "bytes": 8412, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8476da26cb3a69997850987ea8e8a893b9c96b9a2ab6fdd8955e1158ad5804ed" }, { "bytes": 8071, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b20b84cb7f2a5b81642a636d83f3b6a72479ec676c1c18f40ce232c5d71699dd" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089402/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089402", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7d62-8557-4ee35f7957e2" } j2abDG6de3w5410BRlK4Fex6phJjdT/XKjDE/jVe+NQiRw4Y+OpnV6VK6fRWirOTvcXgzVP9q5usuvF3B8XLBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: j2abDG6de3w5410BRlK4Fex6phJjdT/XKjDE/jVe+NQiRw4Y+OpnV6VK6fRWirOTvcXgzVP9q5usuvF3B8XLBg== {"files":[{"bytes":18303,"name":"index.html","sha256":"25cf92f2263c48781a36d25313c1cb899f2007baff6ef50b144a080cd7214612"},{"bytes":7925,"name":"publication.md","sha256":"c2715f6da33da6e71155d5947e2ae62f7f5cfc615597b7033c0d03c34ef96b31"},{"bytes":7590,"name":"publication.txt","sha256":"c69c1afff2aaaa17d0532857a1a97ae740ccfa4edf7d32fdf9fa3bb052a1ccc4"},{"bytes":2852,"name":"manifest.json","sha256":"d03d55488b3ab288dc6ce1fad3bb67805558112b84d01d8896b07c224c557564"},{"bytes":89,"name":"manifest.sig","sha256":"c972ea6290bc71fb35d4bcbc5614d1e32d354cfa8bdfa69e7ba0ba0d1e4478b3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"97812e719d0f526494282f46a9ab5c77c520e4c2d8e83259a43c073ba67d8cef"}],"publication_id":"OT-2026-000089403"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089403
OpenTechnical

OT-2026-000089403

Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
c69c1afff2aaaa17d0532857a1a97ae740ccfa4edf7d32fdf9fa3bb052a1ccc4

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089403, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089403.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089403" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089403" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089403 Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089403 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089403 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089403 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089403", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18303, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "25cf92f2263c48781a36d25313c1cb899f2007baff6ef50b144a080cd7214612" }, { "bytes": 7925, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c2715f6da33da6e71155d5947e2ae62f7f5cfc615597b7033c0d03c34ef96b31" }, { "bytes": 7590, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c69c1afff2aaaa17d0532857a1a97ae740ccfa4edf7d32fdf9fa3bb052a1ccc4" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089403/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089403", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7af0-870d-5e722bc811ea" } 5xMOkdUnxnck9qaR0d0igw5uH0xUYveRtMyAyOw3Pzk7Rub/sLEvc5agfSiFC05uWT/acFy5u22mrP5tkHLRBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 5xMOkdUnxnck9qaR0d0igw5uH0xUYveRtMyAyOw3Pzk7Rub/sLEvc5agfSiFC05uWT/acFy5u22mrP5tkHLRBw== {"files":[{"bytes":19118,"name":"index.html","sha256":"755e7497adcf492363df63d63559414f0177868de05e559bc14b75b4a8074f0d"},{"bytes":8626,"name":"publication.md","sha256":"b0caedb279481cb6231c36e42ac623cc3679ddae9e15837469c72fa264058b85"},{"bytes":8285,"name":"publication.txt","sha256":"c7edb60031666026c1297ed4d39978cb107f121dfa067a18a95a398aa87ce065"},{"bytes":2864,"name":"manifest.json","sha256":"1dbd5acfdd0b4f0b0a8fbdafcac6488f2e7fa02894b916e3d03f558b298b23a9"},{"bytes":89,"name":"manifest.sig","sha256":"e22f48ed648d7233ba74680a570f02edf62b7b8195da0fa8a7b92705e85db3b2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"dcfef6d7a4e3cfb1296144112a992da921df40795f746021d20883b128cf15ae"}],"publication_id":"OT-2026-000089404"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089404
OpenTechnical

OT-2026-000089404

Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c7edb60031666026c1297ed4d39978cb107f121dfa067a18a95a398aa87ce065

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089404, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089404.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089404" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089404" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089404 Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089404 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089404 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089404 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089404", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19118, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "755e7497adcf492363df63d63559414f0177868de05e559bc14b75b4a8074f0d" }, { "bytes": 8626, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b0caedb279481cb6231c36e42ac623cc3679ddae9e15837469c72fa264058b85" }, { "bytes": 8285, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c7edb60031666026c1297ed4d39978cb107f121dfa067a18a95a398aa87ce065" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089404/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089404", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7bdd-b14a-49f2e86f2709" } 8Qce/pb/Ja2sf6++N/o8GRHlFT6Ppu2Xs6efbPxApBMyfWYIUFdDKxMw56fTdXISvvQbcIllps+QExWAtleuDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 8Qce/pb/Ja2sf6++N/o8GRHlFT6Ppu2Xs6efbPxApBMyfWYIUFdDKxMw56fTdXISvvQbcIllps+QExWAtleuDQ== {"files":[{"bytes":18865,"name":"index.html","sha256":"9f7326eae3aa731241ea165fc436bf8c431919cdf55be9bbf63c7fbf1e8bf809"},{"bytes":8416,"name":"publication.md","sha256":"5cbff8d02c4aef472d4f6de0e88ea12f80c2b90dd832be372d58de6ed1c4ce2e"},{"bytes":8075,"name":"publication.txt","sha256":"351b9cb892232ee1a7ca7fa740b85fd98471767e10ea657f3df4a30219305a54"},{"bytes":2864,"name":"manifest.json","sha256":"bd81164e4fde6e04cbc3e3833369a137d980e35a38c723113a178d61d6d089b7"},{"bytes":89,"name":"manifest.sig","sha256":"0e1e536a3638a759cc7a3b36b257aebf27467ffd9d3ae52472d96b84223388dc"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3e48623f5e1b79845131768b0244da71f12cbba6486cccb44f2944bb739be7ee"}],"publication_id":"OT-2026-000089405"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089405
OpenTechnical

OT-2026-000089405

Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
351b9cb892232ee1a7ca7fa740b85fd98471767e10ea657f3df4a30219305a54

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089405, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089405.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089405" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089405" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089405 Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089405 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089405 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089405 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089405", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18865, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9f7326eae3aa731241ea165fc436bf8c431919cdf55be9bbf63c7fbf1e8bf809" }, { "bytes": 8416, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5cbff8d02c4aef472d4f6de0e88ea12f80c2b90dd832be372d58de6ed1c4ce2e" }, { "bytes": 8075, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "351b9cb892232ee1a7ca7fa740b85fd98471767e10ea657f3df4a30219305a54" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089405/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089405", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-78fc-a47d-bb2f254824b5" } v7WbUTJhErEl0rNQWgCGD155/2vOGqh4DTkyXaHLhFLj+K5pH938NfnEgWPb6oPCkJORf+lLyEw21MfVQJquAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: v7WbUTJhErEl0rNQWgCGD155/2vOGqh4DTkyXaHLhFLj+K5pH938NfnEgWPb6oPCkJORf+lLyEw21MfVQJquAQ== {"files":[{"bytes":18492,"name":"index.html","sha256":"c29a4ad8636083eb6e80d3abf949392b10549ad53f10e24f1e662a9a5d713dca"},{"bytes":8082,"name":"publication.md","sha256":"71bf66e5d4ebb21ff467b475a0f7bbc39d4ef570f9c12b9d3110742525f26043"},{"bytes":7757,"name":"publication.txt","sha256":"963f0f1f77efa4f97de691c65eadff49cb1430315c7609165a515080b9d8240f"},{"bytes":2831,"name":"manifest.json","sha256":"ead77219c1e224de52ddbef7f7fb3c8c02f7b5afe3e5489653a3711d25786199"},{"bytes":89,"name":"manifest.sig","sha256":"2aaf5d8669ae6652ba27ef5182b7f19d715e8f3f579ae95fb6bc662153267302"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9b1ad0e7270acb5c97ca3dd936d89844bdcff9a5b9a98068188c8c9158c0cc7b"}],"publication_id":"OT-2026-000089406"} Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089406
OpenTechnical

OT-2026-000089406

Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
963f0f1f77efa4f97de691c65eadff49cb1430315c7609165a515080b9d8240f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089406, “Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089406.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089406" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089406" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089406 Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089406 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089406 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089406 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089406", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1131 }, "figures": [], "files": [ { "bytes": 18492, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c29a4ad8636083eb6e80d3abf949392b10549ad53f10e24f1e662a9a5d713dca" }, { "bytes": 8082, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "71bf66e5d4ebb21ff467b475a0f7bbc39d4ef570f9c12b9d3110742525f26043" }, { "bytes": 7757, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "963f0f1f77efa4f97de691c65eadff49cb1430315c7609165a515080b9d8240f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089406/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089406", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7878-b777-09e9388df68b" } SB99Hm0J4OeFO4RbV0vCc9nzYkAOecGikgrOecV7PH6mPKxwbp/32/DNuQkcbrgbkWqVilGaCiyL1/ncXwA+AA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: SB99Hm0J4OeFO4RbV0vCc9nzYkAOecGikgrOecV7PH6mPKxwbp/32/DNuQkcbrgbkWqVilGaCiyL1/ncXwA+AA== {"files":[{"bytes":19307,"name":"index.html","sha256":"940fd7b8e59ddc9e32ae504089fb1b31f6795086b158f9da2a75b8f64c2a7b5f"},{"bytes":8783,"name":"publication.md","sha256":"9bda32c083fc9b0d803ebbf18c0774ae5812e222f8ff6acc151ec502ded96804"},{"bytes":8452,"name":"publication.txt","sha256":"0fa74cb26a35d3076e5802ca490e9afbf2a04a3237137647de183c8afe579f9d"},{"bytes":2843,"name":"manifest.json","sha256":"42fefd73d09e444ce4bfaf617eee9d388e2008a1b576ab3d678a64b0fce1d263"},{"bytes":89,"name":"manifest.sig","sha256":"2b4d8f119edc9ea6b307ec7c80a551e41294f83bbaba079669676296f1d7e405"},{"bytes":227,"name":"manifest.sig.txt","sha256":"abcb1d15d6157651320325c53cc746b8eb39c2a7178f74d463992f36223d11a0"}],"publication_id":"OT-2026-000089407"} Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089407
OpenTechnical

OT-2026-000089407

Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
0fa74cb26a35d3076e5802ca490e9afbf2a04a3237137647de183c8afe579f9d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089407, “Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089407.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089407" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089407" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089407 Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089407 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089407 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089407 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089407", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1237 }, "figures": [], "files": [ { "bytes": 19307, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "940fd7b8e59ddc9e32ae504089fb1b31f6795086b158f9da2a75b8f64c2a7b5f" }, { "bytes": 8783, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9bda32c083fc9b0d803ebbf18c0774ae5812e222f8ff6acc151ec502ded96804" }, { "bytes": 8452, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0fa74cb26a35d3076e5802ca490e9afbf2a04a3237137647de183c8afe579f9d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089407/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089407", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7413-ba3e-37dfcca01101" } WgRogS4i9ZaoENimS7oydHhnf2loh5exC88Hc+H9gbhcuF71iIpSEE6Vf59xuMf3CQv/+YBBtvfeSbzkLc9iCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: WgRogS4i9ZaoENimS7oydHhnf2loh5exC88Hc+H9gbhcuF71iIpSEE6Vf59xuMf3CQv/+YBBtvfeSbzkLc9iCQ== {"files":[{"bytes":19054,"name":"index.html","sha256":"56f0a8a5f8b434c50bd938f89d4c931a97a0d0b409b3fa4974c4203fc2e2c6da"},{"bytes":8573,"name":"publication.md","sha256":"8801e448007b8ce305699015552b9d0eb7ee951fa05fc6eb2a5ffe123eb6d69a"},{"bytes":8242,"name":"publication.txt","sha256":"3de8ca4a473ff166d5051e4e0ac628da18222eabdd4cce24098eeb1582592813"},{"bytes":2843,"name":"manifest.json","sha256":"d1730db15df532fd5016d9bd10c6ae9760b3478e41a2ce4dd2a87d9072faee5d"},{"bytes":89,"name":"manifest.sig","sha256":"0788e307447f0016b7b171031d0c9b2200c6fd85f2f98946925e71ed67d67809"},{"bytes":227,"name":"manifest.sig.txt","sha256":"88316e516114b3496003e8e634e3dc4956aadcb5c4a29722cbe788cb0be51323"}],"publication_id":"OT-2026-000089408"} Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089408
OpenTechnical

OT-2026-000089408

Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
3de8ca4a473ff166d5051e4e0ac628da18222eabdd4cce24098eeb1582592813

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089408, “Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089408.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089408" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089408" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089408 Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089408 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089408 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089408 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089408", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19054, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "56f0a8a5f8b434c50bd938f89d4c931a97a0d0b409b3fa4974c4203fc2e2c6da" }, { "bytes": 8573, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8801e448007b8ce305699015552b9d0eb7ee951fa05fc6eb2a5ffe123eb6d69a" }, { "bytes": 8242, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3de8ca4a473ff166d5051e4e0ac628da18222eabdd4cce24098eeb1582592813" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089408/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089408", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-70cd-adb6-046d2e24f1e1" } 3v8D3cRaJvPAN5SJDrUDlMfkPsZhAZ30jRkRhv1yBd2QwKXKTBC/yn87nSZ66xUFlInp3pqew/9NroX+ng31AQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 3v8D3cRaJvPAN5SJDrUDlMfkPsZhAZ30jRkRhv1yBd2QwKXKTBC/yn87nSZ66xUFlInp3pqew/9NroX+ng31AQ== {"files":[{"bytes":18438,"name":"index.html","sha256":"085f277198176797776f9c8c237b5b8aace049446c893d0897c84ae7bc683021"},{"bytes":8028,"name":"publication.md","sha256":"f00d95f3d55fe3760cceb4482306548714333c60da1998dc0b4976c8c4618739"},{"bytes":7703,"name":"publication.txt","sha256":"d3537ced382b710110b302b34ee7a4a8052d250f9ab57aef20400bc182ec1c04"},{"bytes":2831,"name":"manifest.json","sha256":"3b499ddb058934f2b0f182029c55b38d49c06cdf7f553a3e6f8a4d900afa6e4e"},{"bytes":89,"name":"manifest.sig","sha256":"e653e28521cbda2b18b74cd3d118301415fe557d25a9b75c6ad5720cf53ec950"},{"bytes":227,"name":"manifest.sig.txt","sha256":"14553695a14c564c73fb0838c66c059748738079b0c2deb52b443a0903018670"}],"publication_id":"OT-2026-000089409"} Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089409
OpenTechnical

OT-2026-000089409

Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
d3537ced382b710110b302b34ee7a4a8052d250f9ab57aef20400bc182ec1c04

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089409, “Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089409.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089409" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089409" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089409 Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089409 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089409 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089409 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089409", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1116 }, "figures": [], "files": [ { "bytes": 18438, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "085f277198176797776f9c8c237b5b8aace049446c893d0897c84ae7bc683021" }, { "bytes": 8028, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f00d95f3d55fe3760cceb4482306548714333c60da1998dc0b4976c8c4618739" }, { "bytes": 7703, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d3537ced382b710110b302b34ee7a4a8052d250f9ab57aef20400bc182ec1c04" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089409/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089409", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7bc9-9c5c-3077cef17486" } +3o9gt39N3DXLc+13qW1WBwMkpH5zHFpUF2dFrigjkvhjC50zDowwDHdhYpBBS/xw1Ib/M/AUQtCdSVtITxhDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: +3o9gt39N3DXLc+13qW1WBwMkpH5zHFpUF2dFrigjkvhjC50zDowwDHdhYpBBS/xw1Ib/M/AUQtCdSVtITxhDg== {"files":[{"bytes":19253,"name":"index.html","sha256":"214dd514e9ec95e7458c918c498a2c19869539f00a0a02d5927915bfc712791e"},{"bytes":8729,"name":"publication.md","sha256":"3274198af9897aaf4021f2278f4b8649e70c8c5552e89105b20aed11a93b2ec2"},{"bytes":8398,"name":"publication.txt","sha256":"87725fd9e892c694207b5eb5278108980f41880acb5a6bb5b7084d84895d30f7"},{"bytes":2843,"name":"manifest.json","sha256":"1506eeb9d96653673923e345b02168e735e879002218964509d471a1b18475f9"},{"bytes":89,"name":"manifest.sig","sha256":"09d3dd08351e97a003ba1da6fb4c8e277e7c07043d5ffa27ae9c39a710986e94"},{"bytes":227,"name":"manifest.sig.txt","sha256":"bdcd0e020c45a47c725c7070bcac7dadd689d1fbe181ae715adaeb28654294c6"}],"publication_id":"OT-2026-000089410"} Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089410
OpenTechnical

OT-2026-000089410

Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
87725fd9e892c694207b5eb5278108980f41880acb5a6bb5b7084d84895d30f7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089410, “Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089410.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089410" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089410" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089410 Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089410 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089410 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089410 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089410", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1222 }, "figures": [], "files": [ { "bytes": 19253, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "214dd514e9ec95e7458c918c498a2c19869539f00a0a02d5927915bfc712791e" }, { "bytes": 8729, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3274198af9897aaf4021f2278f4b8649e70c8c5552e89105b20aed11a93b2ec2" }, { "bytes": 8398, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "87725fd9e892c694207b5eb5278108980f41880acb5a6bb5b7084d84895d30f7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089410/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089410", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7009-a6d4-83c77792b17b" } YPomXjCKCHF87grI3EzsULZtTBuT1Es3vFc+8o+gHP1H/dgmIPbf9hM+4BmhminC267YIKNvktJGEJBba4WlBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: YPomXjCKCHF87grI3EzsULZtTBuT1Es3vFc+8o+gHP1H/dgmIPbf9hM+4BmhminC267YIKNvktJGEJBba4WlBQ== {"files":[{"bytes":19000,"name":"index.html","sha256":"b37a4fbfbaa9e9c9c5b84ac848f5271aba658591240f30950ca29e90d915d629"},{"bytes":8519,"name":"publication.md","sha256":"27c1d5c33757a9190549ea06c02677a63f4ddf3afbf169818766be5ac547b54c"},{"bytes":8188,"name":"publication.txt","sha256":"faf92ab6bfd0e74981c0091f605b6fb2a6ad600ed2edb33114a29ca3977ecf1e"},{"bytes":2843,"name":"manifest.json","sha256":"444ff8f78f889c7d1deb048ba53603f235d27ea8123ad19870953064396000e6"},{"bytes":89,"name":"manifest.sig","sha256":"6af793b6cfad92cd4c502e7d729c0123ccaabcedd598cfde405ea3c5814e5cf9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2100f5f552ef685674d2bddb69042d47813f85bd8758e73e026f1e6987dba13f"}],"publication_id":"OT-2026-000089411"} Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089411
OpenTechnical

OT-2026-000089411

Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
faf92ab6bfd0e74981c0091f605b6fb2a6ad600ed2edb33114a29ca3977ecf1e

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089411, “Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089411.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089411" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089411" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089411 Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089411 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089411 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089411 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089411", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1187 }, "figures": [], "files": [ { "bytes": 19000, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b37a4fbfbaa9e9c9c5b84ac848f5271aba658591240f30950ca29e90d915d629" }, { "bytes": 8519, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "27c1d5c33757a9190549ea06c02677a63f4ddf3afbf169818766be5ac547b54c" }, { "bytes": 8188, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "faf92ab6bfd0e74981c0091f605b6fb2a6ad600ed2edb33114a29ca3977ecf1e" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089411/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089411", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7e41-ae53-bee9c81cdc64" } SgN3p2Ol1yzBohwP6U6e3RBYzIBIzNP+0iRZN8LTgQDZgGu9se3Z+ZKcD5ZRwXGDhZpv4AfPSelQ8lRvz1FhBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: SgN3p2Ol1yzBohwP6U6e3RBYzIBIzNP+0iRZN8LTgQDZgGu9se3Z+ZKcD5ZRwXGDhZpv4AfPSelQ8lRvz1FhBw== {"files":[{"bytes":18192,"name":"index.html","sha256":"932e9a2299aa0c0ede3e525bc3fb94179f02cfa8e34d58066a45c6f17a644f75"},{"bytes":7830,"name":"publication.md","sha256":"5ea0a4658e900363ad3e4c9b1a59875addb4e158b5d1b50e96972b721be44124"},{"bytes":7503,"name":"publication.txt","sha256":"7a4350dccddc6347e665048cbc1eb271e8536c725c87030974fa5a9d0450099b"},{"bytes":2844,"name":"manifest.json","sha256":"d9a53198ecbe3adef1ccf21f92ca6ced8ab7c499c7ac805160e7252c41e6ae3c"},{"bytes":89,"name":"manifest.sig","sha256":"d9308aec5dee3c0d9aba49f15cbf27d0580d3fc7e279e7d3677bfa852cf64adb"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a5c8aa7ad6f025fd56e6f64e6c8c76b63cb198e94f74f1e0870e89a0d910f1cc"}],"publication_id":"OT-2026-000089412"} Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089412
OpenTechnical

OT-2026-000089412

Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
7a4350dccddc6347e665048cbc1eb271e8536c725c87030974fa5a9d0450099b

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089412, “Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089412.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089412" title: "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089412" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089412 Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089412 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089412 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089412 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089412", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1079 }, "figures": [], "files": [ { "bytes": 18192, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "932e9a2299aa0c0ede3e525bc3fb94179f02cfa8e34d58066a45c6f17a644f75" }, { "bytes": 7830, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5ea0a4658e900363ad3e4c9b1a59875addb4e158b5d1b50e96972b721be44124" }, { "bytes": 7503, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7a4350dccddc6347e665048cbc1eb271e8536c725c87030974fa5a9d0450099b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089412/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089412", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-7fd2-bac2-2679a21b0b08" } hShgWBFSoTeRvd1G8zpG+XaEANFjRTULEeO4OR7LyQnXX4DKIw56uJiWkC8kGHwHteGOBz6yfklKtYRZAySkAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: hShgWBFSoTeRvd1G8zpG+XaEANFjRTULEeO4OR7LyQnXX4DKIw56uJiWkC8kGHwHteGOBz6yfklKtYRZAySkAQ== {"files":[{"bytes":19007,"name":"index.html","sha256":"a25e304b6706db9ca46b26e1ba98048ce98767eb44f072e7e56ebbaa7f41139d"},{"bytes":8531,"name":"publication.md","sha256":"2dd3c4969bcc26d838b90eee83c04247c74ea6ec713f54c264fc4c19992bce9e"},{"bytes":8198,"name":"publication.txt","sha256":"944331e68f1fb533c4ed725b9b095c7271e9b0e22cd17b95d546324f25826787"},{"bytes":2856,"name":"manifest.json","sha256":"3e5c1ac4ffbad0c49bf583b8568dbff14c8abb75c75c1e5d890ccc9ec82e7795"},{"bytes":89,"name":"manifest.sig","sha256":"29b9af0de23cb96550fd17c93d0d5a3ab5a8ccac71da7f56151fd1e0e91816d3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d00c346778e16eab7fc5d2c26068f68829b554ef3fecdfe275f050c6c089306d"}],"publication_id":"OT-2026-000089413"} Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089413
OpenTechnical

OT-2026-000089413

Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
944331e68f1fb533c4ed725b9b095c7271e9b0e22cd17b95d546324f25826787

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089413, “Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089413.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089413" title: "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089413" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089413 Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089413 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089413 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089413 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089413", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1185 }, "figures": [], "files": [ { "bytes": 19007, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a25e304b6706db9ca46b26e1ba98048ce98767eb44f072e7e56ebbaa7f41139d" }, { "bytes": 8531, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "2dd3c4969bcc26d838b90eee83c04247c74ea6ec713f54c264fc4c19992bce9e" }, { "bytes": 8198, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "944331e68f1fb533c4ed725b9b095c7271e9b0e22cd17b95d546324f25826787" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089413/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089413", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7abd-8e3e-c511bebb2ba1" } tCI36JO1qvtEP/rlv3hahhqUKNM4mromV3+rlPXeM2kD+r/pGzhd87kPgyxpysRL1PMM44BvDtS++X8CCx3hCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: tCI36JO1qvtEP/rlv3hahhqUKNM4mromV3+rlPXeM2kD+r/pGzhd87kPgyxpysRL1PMM44BvDtS++X8CCx3hCQ== {"files":[{"bytes":18754,"name":"index.html","sha256":"228de07c31750ced33759a56a20c16f151e7ce32e86295e1d98bc627cf518563"},{"bytes":8321,"name":"publication.md","sha256":"b71c7c2bdc5edcbc3fe9ecdd6d1c7369fc6f4e7d77d5d02b6d567b4594f8e56f"},{"bytes":7988,"name":"publication.txt","sha256":"2d54ccc2948fa229e47b462aca5d776e158ca0b4dc6fdc3f1e326a9a49f2ba47"},{"bytes":2856,"name":"manifest.json","sha256":"9ae1b3e56193918606444dfa7dda1cedf61e55824cf53ab263c9d5f86af5ce4a"},{"bytes":89,"name":"manifest.sig","sha256":"4d577c56ad0ba295dc701854a3be73fedd53f14739e0681e7b874743a4c1e5d0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"07180b4278c5b6a1afe3d27cacfe1bab204c35af6ec99d1b6d56b75e9abe97bb"}],"publication_id":"OT-2026-000089414"} Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089414
OpenTechnical

OT-2026-000089414

Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
2d54ccc2948fa229e47b462aca5d776e158ca0b4dc6fdc3f1e326a9a49f2ba47

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089414, “Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089414.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089414" title: "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089414" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089414 Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089414 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089414 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089414 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089414", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1150 }, "figures": [], "files": [ { "bytes": 18754, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "228de07c31750ced33759a56a20c16f151e7ce32e86295e1d98bc627cf518563" }, { "bytes": 8321, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b71c7c2bdc5edcbc3fe9ecdd6d1c7369fc6f4e7d77d5d02b6d567b4594f8e56f" }, { "bytes": 7988, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2d54ccc2948fa229e47b462aca5d776e158ca0b4dc6fdc3f1e326a9a49f2ba47" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089414/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089414", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7b6c-ba53-6ea2a4a2cb34" } E8YV2EvnhskScQeiTvYVrwlvXDkVEwdX13GN/JPC8edOkfO3q4h49bthKakxxcZZHbmvmFfOXU4X4pVTjQosBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: E8YV2EvnhskScQeiTvYVrwlvXDkVEwdX13GN/JPC8edOkfO3q4h49bthKakxxcZZHbmvmFfOXU4X4pVTjQosBg== {"files":[{"bytes":18192,"name":"index.html","sha256":"95bdd117a5b849ee72f2203e3cd85ca6e890f56caedccf3c3818647994e200ed"},{"bytes":7830,"name":"publication.md","sha256":"2060f0be1d05d5db1dcd211e3caf4822afcc930f2dac126c79c52ad2e3d2a8c8"},{"bytes":7503,"name":"publication.txt","sha256":"07e0b7908f2321f93c9fefc5295151f271e2476675e642196d647f5e2c9f137b"},{"bytes":2844,"name":"manifest.json","sha256":"f545741e61d4f7530410257c46dbbc16de96c5c34f249a5a5b2f0738906fcddd"},{"bytes":89,"name":"manifest.sig","sha256":"c2f1757329da50b6aa956bffc69b02d119c282da9ae2902f7275a930ea43a2c7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b155bb7078e8bee97626180a6f5ec1bf6f613968aec7a81934596aa2aff49c4d"}],"publication_id":"OT-2026-000089415"} Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089415
OpenTechnical

OT-2026-000089415

Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
07e0b7908f2321f93c9fefc5295151f271e2476675e642196d647f5e2c9f137b

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089415, “Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089415.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089415" title: "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089415" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089415 Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089415 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089415 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089415 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089415", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1079 }, "figures": [], "files": [ { "bytes": 18192, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "95bdd117a5b849ee72f2203e3cd85ca6e890f56caedccf3c3818647994e200ed" }, { "bytes": 7830, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "2060f0be1d05d5db1dcd211e3caf4822afcc930f2dac126c79c52ad2e3d2a8c8" }, { "bytes": 7503, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "07e0b7908f2321f93c9fefc5295151f271e2476675e642196d647f5e2c9f137b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089415/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089415", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db01-73cf-bb1d-d63a0854c9a8" } cdi4/hTwEyqs+iOVlhqxpM8O5+ouSTvqqcDbm/Guxlgb0COgsrrSv4aPKU4FV4KvO/koAsMmPVa1Wjcku7IXAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: cdi4/hTwEyqs+iOVlhqxpM8O5+ouSTvqqcDbm/Guxlgb0COgsrrSv4aPKU4FV4KvO/koAsMmPVa1Wjcku7IXAQ== {"files":[{"bytes":19007,"name":"index.html","sha256":"292b7ba9943a5c7ae1d7099224306ecad6b68aa4a5f2672eb95781bd903b06e1"},{"bytes":8531,"name":"publication.md","sha256":"3044180240d9555b25243402f444fc0f87e1cb329087a88e704d101044209a49"},{"bytes":8198,"name":"publication.txt","sha256":"c3b136fa0895a01ae98d8bebd1abf01699c0f65a55d11e5d848613f3210136e3"},{"bytes":2856,"name":"manifest.json","sha256":"6ca29cc16e0add9f0716ddf1b2b4e2ec249d1e982639eae61e01903922a78aa6"},{"bytes":89,"name":"manifest.sig","sha256":"b35727d7dcd51d0336927af96a414a775fa86ed54ec20661b54f52a86de57405"},{"bytes":227,"name":"manifest.sig.txt","sha256":"55972f1156fb99a3eeb962a454996fa5c1c5405679045a55316e769bb285c61a"}],"publication_id":"OT-2026-000089416"} Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089416
OpenTechnical

OT-2026-000089416

Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c3b136fa0895a01ae98d8bebd1abf01699c0f65a55d11e5d848613f3210136e3

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089416, “Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089416.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089416" title: "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089416" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089416 Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089416 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089416 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089416 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089416", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1185 }, "figures": [], "files": [ { "bytes": 19007, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "292b7ba9943a5c7ae1d7099224306ecad6b68aa4a5f2672eb95781bd903b06e1" }, { "bytes": 8531, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3044180240d9555b25243402f444fc0f87e1cb329087a88e704d101044209a49" }, { "bytes": 8198, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c3b136fa0895a01ae98d8bebd1abf01699c0f65a55d11e5d848613f3210136e3" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089416/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089416", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-7519-bcbc-f6e2e0244bf3" } o6QrPyOMo1mvdly95XQiE8Ev/Wu2WY7ylCsTfNMEceVWaGwZQoJM9DQT/mQ/YXjyajuzVykaYhBAalpDk3ZSDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: o6QrPyOMo1mvdly95XQiE8Ev/Wu2WY7ylCsTfNMEceVWaGwZQoJM9DQT/mQ/YXjyajuzVykaYhBAalpDk3ZSDA== {"files":[{"bytes":18754,"name":"index.html","sha256":"63c1215747df5dc79ca8b14bf43d0d5ab43ce91dd4b1ef4173d65144ff10adf2"},{"bytes":8321,"name":"publication.md","sha256":"c43d41de6f89571aab2c18e628ca26f347338db289ddd555d6a74825e7ccc626"},{"bytes":7988,"name":"publication.txt","sha256":"1379000b6ffb5e90269bbba28f177edd371845c0a85326b4b7106be942e8d3a2"},{"bytes":2856,"name":"manifest.json","sha256":"a72ca079144b7d02e27381ede7e1ff8a19a653c20b9ca372c9d01ff003d52732"},{"bytes":89,"name":"manifest.sig","sha256":"4f7844485fc1b82a7db158b07f2b8f2228dce1f34044753c36973b1f9117c6c5"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9f5b3f4db21457bfd1ae06abacd4ddc4562a2e4018bf76cf32207c33c70f7c32"}],"publication_id":"OT-2026-000089417"} Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089417
OpenTechnical

OT-2026-000089417

Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
1379000b6ffb5e90269bbba28f177edd371845c0a85326b4b7106be942e8d3a2

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089417, “Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089417.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089417" title: "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089417" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089417 Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089417 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089417 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089417 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089417", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1150 }, "figures": [], "files": [ { "bytes": 18754, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "63c1215747df5dc79ca8b14bf43d0d5ab43ce91dd4b1ef4173d65144ff10adf2" }, { "bytes": 8321, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c43d41de6f89571aab2c18e628ca26f347338db289ddd555d6a74825e7ccc626" }, { "bytes": 7988, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1379000b6ffb5e90269bbba28f177edd371845c0a85326b4b7106be942e8d3a2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089417/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089417", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, two outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db01-70cd-8ca9-7a10404713b3" } pYeCbwQGRaeoyRDMzUUUHo8/bYf94cBsSZ9bKBSr3V/elmF0k5sh/msNNjDgFErBO7BT7+o4eiOtnjZOGKf3Dg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: pYeCbwQGRaeoyRDMzUUUHo8/bYf94cBsSZ9bKBSr3V/elmF0k5sh/msNNjDgFErBO7BT7+o4eiOtnjZOGKf3Dg== {"files":[{"bytes":18189,"name":"index.html","sha256":"e8480849e2fab3aff428cce3284348e140b35d090fe5d7b37fb8c7f0fc92f0c1"},{"bytes":7880,"name":"publication.md","sha256":"aa16a32e9cc911a28bc961421fc3f55dfdd8e76f661fa043e3c8904a66f18e5c"},{"bytes":7525,"name":"publication.txt","sha256":"7bc91eb5f5175d5b1f061549dceb21fa9058c01516cad8d8258ce7b0f09f16a9"},{"bytes":2904,"name":"manifest.json","sha256":"b2e7a23672bd22a4b3ea60c00322099d3b3d9ac6ef74808d095c8cb5ada5ceb6"},{"bytes":89,"name":"manifest.sig","sha256":"8567de4936fd515d96da2cfae5c6997f0d524c5cc52aac193e16bee3a29920c2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1ac3b5531e19c2036c319c042179bc7badc40c4623342db1260fb15182fa3ee1"}],"publication_id":"OT-2026-000089418"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089418
OpenTechnical

OT-2026-000089418

Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
7bc91eb5f5175d5b1f061549dceb21fa9058c01516cad8d8258ce7b0f09f16a9

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0029]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0030]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089418, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089418.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089418" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089418" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0030] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089418 Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089418 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0030] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089418 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089418 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089418", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 30, "words": 1074 }, "figures": [], "files": [ { "bytes": 18189, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "e8480849e2fab3aff428cce3284348e140b35d090fe5d7b37fb8c7f0fc92f0c1" }, { "bytes": 7880, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "aa16a32e9cc911a28bc961421fc3f55dfdd8e76f661fa043e3c8904a66f18e5c" }, { "bytes": 7525, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7bc91eb5f5175d5b1f061549dceb21fa9058c01516cad8d8258ce7b0f09f16a9" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089418/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089418", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-761a-83fd-25f989ec6ecc" } r8H3D2tPo8QnxPB4bU2CjBoE0/c/VICdZoPwEUtslvwvZOCm45ftzh8tdIt8uBGjVwk5BB4muHRAx5CIEBOFAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: r8H3D2tPo8QnxPB4bU2CjBoE0/c/VICdZoPwEUtslvwvZOCm45ftzh8tdIt8uBGjVwk5BB4muHRAx5CIEBOFAQ== {"files":[{"bytes":18995,"name":"index.html","sha256":"95a146e98bd3c5c2ace2e3074cea92683d2de8559ecfe3cf5cf76399f3fd85a9"},{"bytes":8568,"name":"publication.md","sha256":"abd3b2e0b119985d5d0209b7a610629743195c3eb3254fe72e182f2f864cbf56"},{"bytes":8214,"name":"publication.txt","sha256":"d2b86d29413d78ce6f321c0fd8b646ecc79e9433b6fbc14ebcbb98bcada4188e"},{"bytes":2909,"name":"manifest.json","sha256":"769ac558dc9aa07e86a216af2d8e9c9be96d30f5cb4648dd565c38c4e319bf6c"},{"bytes":89,"name":"manifest.sig","sha256":"e83260477f362c35a45bfb019b2b2505741882a602de8a3ac1e0ca09c608eb14"},{"bytes":227,"name":"manifest.sig.txt","sha256":"fb995a62089311ae5472b8b27cf5092a7cd789babec06c6f9bf82d42f98605e0"}],"publication_id":"OT-2026-000089419"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089419
OpenTechnical

OT-2026-000089419

Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
d2b86d29413d78ce6f321c0fd8b646ecc79e9433b6fbc14ebcbb98bcada4188e

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0019]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089419, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089419.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089419" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089419" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089419 Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089419 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089419 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089419 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089419", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1180 }, "figures": [], "files": [ { "bytes": 18995, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "95a146e98bd3c5c2ace2e3074cea92683d2de8559ecfe3cf5cf76399f3fd85a9" }, { "bytes": 8568, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "abd3b2e0b119985d5d0209b7a610629743195c3eb3254fe72e182f2f864cbf56" }, { "bytes": 8214, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d2b86d29413d78ce6f321c0fd8b646ecc79e9433b6fbc14ebcbb98bcada4188e" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089419/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089419", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-72ec-9855-54adae1a65fe" } a/fki1PWwOaId7UeXkWDoHiRR/8T5ZMhAKAwJTaj59S5jBLX9qZuhOeEM8MrVgJy5lounC8LnTnE9KjORGBEAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: a/fki1PWwOaId7UeXkWDoHiRR/8T5ZMhAKAwJTaj59S5jBLX9qZuhOeEM8MrVgJy5lounC8LnTnE9KjORGBEAA== {"files":[{"bytes":18742,"name":"index.html","sha256":"f11a3e5405b4c694d9f8a29d9208cf9a50f4d3c43942f7d6c81f751ca003a2d9"},{"bytes":8358,"name":"publication.md","sha256":"e8eb2224d535b16d876a15448bdfc7e5b798c4db888ca9f710f62abc267a346e"},{"bytes":8004,"name":"publication.txt","sha256":"67d9ae5e35597fab8d77ec785f71cb2bc55382ec2b85836a4a537ad2cd6acaaf"},{"bytes":2909,"name":"manifest.json","sha256":"6f3c1feb4d44ecfca915c24c2b71517f2d4333189a801b7b2992d42c36ec81a0"},{"bytes":89,"name":"manifest.sig","sha256":"70465d5bd4ad4b84595c3ce85541fc56c24d131c31abef5a1564e09c07e2d5ef"},{"bytes":227,"name":"manifest.sig.txt","sha256":"98379c7f214d50996dd97593181be563061d292753002ea0e2314bdcdd772a35"}],"publication_id":"OT-2026-000089420"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089420
OpenTechnical

OT-2026-000089420

Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
67d9ae5e35597fab8d77ec785f71cb2bc55382ec2b85836a4a537ad2cd6acaaf

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0029]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089420, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089420.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089420" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089420" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089420 Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089420 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089420 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089420 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089420", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1145 }, "figures": [], "files": [ { "bytes": 18742, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f11a3e5405b4c694d9f8a29d9208cf9a50f4d3c43942f7d6c81f751ca003a2d9" }, { "bytes": 8358, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e8eb2224d535b16d876a15448bdfc7e5b798c4db888ca9f710f62abc267a346e" }, { "bytes": 8004, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "67d9ae5e35597fab8d77ec785f71cb2bc55382ec2b85836a4a537ad2cd6acaaf" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089420/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089420", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7076-aaa5-6bea24cae774" } hM5KE+RwROwRGLbXtqz7OuxmfUIoXMWkdhQPL4FKY0crJIhcgAz7YyHpcMPVNeeU5sGjiHf8wsNZrxku0kDACA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: hM5KE+RwROwRGLbXtqz7OuxmfUIoXMWkdhQPL4FKY0crJIhcgAz7YyHpcMPVNeeU5sGjiHf8wsNZrxku0kDACA== {"files":[{"bytes":18190,"name":"index.html","sha256":"232de67fd11878d6e15f7bf3ae7941b7b668d43a7cb9cb9bae92a313324dc770"},{"bytes":7881,"name":"publication.md","sha256":"00a406c3c71625136f3bf49dab5ba2191c41eb3d3b391004d7369789e7f1a16d"},{"bytes":7526,"name":"publication.txt","sha256":"5df5c30fcf6993c0feb14ddbfb596c014af51b48477c7bda885ae500036f075f"},{"bytes":2904,"name":"manifest.json","sha256":"2799bcec7c7c01252779dfefea015d61ab151565e1209862734b2c954660799f"},{"bytes":89,"name":"manifest.sig","sha256":"5aa7c22ed31cd6d1a0b0d2bded76d002714efa60d50f30fae85829feec8d5217"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ebb6e9ac12396eb13f6586a452c0ab86a50483a13eaf557c97450e7144001edf"}],"publication_id":"OT-2026-000089421"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089421
OpenTechnical

OT-2026-000089421

Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
5df5c30fcf6993c0feb14ddbfb596c014af51b48477c7bda885ae500036f075f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0029]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0030]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089421, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089421.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089421" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089421" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0030] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089421 Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089421 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0030] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089421 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089421 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089421", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 30, "words": 1074 }, "figures": [], "files": [ { "bytes": 18190, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "232de67fd11878d6e15f7bf3ae7941b7b668d43a7cb9cb9bae92a313324dc770" }, { "bytes": 7881, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "00a406c3c71625136f3bf49dab5ba2191c41eb3d3b391004d7369789e7f1a16d" }, { "bytes": 7526, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5df5c30fcf6993c0feb14ddbfb596c014af51b48477c7bda885ae500036f075f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089421/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089421", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-73a2-b0f9-cd4315f6c4b9" } b4pHUtZVNurHwinwT+/avxYWNJZ2Uh9Uw4y6RUj5XcxHzEfp4PkOuNJeZ8VdW7zpjiTTe41nyqpFAd4SawXgCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: b4pHUtZVNurHwinwT+/avxYWNJZ2Uh9Uw4y6RUj5XcxHzEfp4PkOuNJeZ8VdW7zpjiTTe41nyqpFAd4SawXgCg== {"files":[{"bytes":18996,"name":"index.html","sha256":"579e00c47a218f64ebf479ac9cda22bb4503ac38f66af3cee2b1f7a86b36fd62"},{"bytes":8569,"name":"publication.md","sha256":"888ed9efce44d18b2f7032f1a96d6b103ad4adac67a5192fdf728118a32095b6"},{"bytes":8215,"name":"publication.txt","sha256":"95d0e1ed91a5a875a19ec3aa71dda7acacf74215aaae1d44a3dd8e50ed85f342"},{"bytes":2909,"name":"manifest.json","sha256":"10ef189ed2ce3b2d5f25687c4e5a174dd3248da00be8db49a866a0a7e5e06026"},{"bytes":89,"name":"manifest.sig","sha256":"8d127990dbc526294ea4075c8930b84f5f5b0e9454870043ec1ac684f455906e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"20437196eaf48fad49530cd8f486db10a60d015470ebb43acdfb7ac5f700af3e"}],"publication_id":"OT-2026-000089422"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089422
OpenTechnical

OT-2026-000089422

Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
95d0e1ed91a5a875a19ec3aa71dda7acacf74215aaae1d44a3dd8e50ed85f342

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0019]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089422, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089422.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089422" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089422" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089422 Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089422 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089422 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089422 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089422", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1180 }, "figures": [], "files": [ { "bytes": 18996, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "579e00c47a218f64ebf479ac9cda22bb4503ac38f66af3cee2b1f7a86b36fd62" }, { "bytes": 8569, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "888ed9efce44d18b2f7032f1a96d6b103ad4adac67a5192fdf728118a32095b6" }, { "bytes": 8215, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "95d0e1ed91a5a875a19ec3aa71dda7acacf74215aaae1d44a3dd8e50ed85f342" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089422/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089422", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-71ba-8df8-b3f2fd9a2c6d" } VRCtoUow2udNRtkRzKxsaxQp9j6KZRaR1RFdaaE26DsITsQWVlbKm1TFhOoSu8qeNn94325lIfrGV6rBVdlVCg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: VRCtoUow2udNRtkRzKxsaxQp9j6KZRaR1RFdaaE26DsITsQWVlbKm1TFhOoSu8qeNn94325lIfrGV6rBVdlVCg== {"files":[{"bytes":18743,"name":"index.html","sha256":"f2b30d9362d7a6cb80d921941c4b40e3bea7d72e082f6762f3e88803ededf62f"},{"bytes":8359,"name":"publication.md","sha256":"3743549e15b2d1ec3394cce21d12c164837fd7f32b247e57e239cf655a3055ae"},{"bytes":8005,"name":"publication.txt","sha256":"5c68444b25f7d159c75a2b2cd0edc95183eea000e004abda37bd6be29c4726df"},{"bytes":2909,"name":"manifest.json","sha256":"729de723c805aca5a3a00f93abd5c5ef5a26595c6d27c7cf6dbe7a7ad8d16516"},{"bytes":89,"name":"manifest.sig","sha256":"2e4d8f3c970b8c7122781d45b430f04d3d013bb8ba58d9f1f030809cf320b05e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3a2f3e97e6607e8dc2e072fc2d31c0326d99832eb0fd053e6e031fe0c5731e9e"}],"publication_id":"OT-2026-000089423"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089423
OpenTechnical

OT-2026-000089423

Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
5c68444b25f7d159c75a2b2cd0edc95183eea000e004abda37bd6be29c4726df

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0029]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089423, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089423.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089423" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089423" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089423 Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089423 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089423 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089423 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089423", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1145 }, "figures": [], "files": [ { "bytes": 18743, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f2b30d9362d7a6cb80d921941c4b40e3bea7d72e082f6762f3e88803ededf62f" }, { "bytes": 8359, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3743549e15b2d1ec3394cce21d12c164837fd7f32b247e57e239cf655a3055ae" }, { "bytes": 8005, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5c68444b25f7d159c75a2b2cd0edc95183eea000e004abda37bd6be29c4726df" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089423/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089423", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7257-a841-400ad269fbbc" } yyWgAQANTK7TQ55K3ABbKFJJ12qcMkrO2waA+xjNILtiI3D15eGfV238MlqAeXTxO2dHQPTMDcg6ajEeERJYDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: yyWgAQANTK7TQ55K3ABbKFJJ12qcMkrO2waA+xjNILtiI3D15eGfV238MlqAeXTxO2dHQPTMDcg6ajEeERJYDA== {"files":[{"bytes":18194,"name":"index.html","sha256":"656ae9ca82eaec383a64999f749270ecd205e854d187e144ad2e2fcbe7b38145"},{"bytes":7885,"name":"publication.md","sha256":"76c7177ccfc877f6c2cd0d1ef65301fc754691fbc6095eaddba78fc0bf22804f"},{"bytes":7530,"name":"publication.txt","sha256":"b4a682121e889a97dac90cdb49141f842bbaf86ba83f958297707aea8fff28d4"},{"bytes":2904,"name":"manifest.json","sha256":"1d15906a55e3fd62ecffc7d410ff54dccfb09b90ec3db06dbd59c25f44525ac2"},{"bytes":89,"name":"manifest.sig","sha256":"0a91b20004d1064887e1edc8984c89b7b373d76e5ef7e1a6b22026dc345d794f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"cb7a6a2d7db433e4000d2e15990943cce7f536f0cdd01255259185fe8bf67fde"}],"publication_id":"OT-2026-000089424"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089424
OpenTechnical

OT-2026-000089424

Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
b4a682121e889a97dac90cdb49141f842bbaf86ba83f958297707aea8fff28d4

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0029]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0030]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089424, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089424.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089424" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089424" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0030] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089424 Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089424 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0030] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089424 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089424 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089424", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 30, "words": 1074 }, "figures": [], "files": [ { "bytes": 18194, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "656ae9ca82eaec383a64999f749270ecd205e854d187e144ad2e2fcbe7b38145" }, { "bytes": 7885, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "76c7177ccfc877f6c2cd0d1ef65301fc754691fbc6095eaddba78fc0bf22804f" }, { "bytes": 7530, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b4a682121e889a97dac90cdb49141f842bbaf86ba83f958297707aea8fff28d4" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089424/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089424", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-79b9-8097-6d7861902f3a" } lST5BwEiQEnvFQC/HSK0Ya6nDWjTOXH2EdYvSZOfiXLtQf5o3hpDbJk3Slytp/51vc5hz9L5Jk2oTwo3RaHNAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: lST5BwEiQEnvFQC/HSK0Ya6nDWjTOXH2EdYvSZOfiXLtQf5o3hpDbJk3Slytp/51vc5hz9L5Jk2oTwo3RaHNAw== {"files":[{"bytes":19000,"name":"index.html","sha256":"a924abc304421cb14474f72787e812e838def616ff505554cedb2f11cb1eb6b8"},{"bytes":8573,"name":"publication.md","sha256":"20d19686c0da552a42cd57d217d9ecdb96dfcf9717761045552a69bd764100eb"},{"bytes":8219,"name":"publication.txt","sha256":"7807f4b4476c934ce8fe87ce39ef0d80d613640fbbe5725bce8452632c4796da"},{"bytes":2909,"name":"manifest.json","sha256":"9d4a34567d1db79015d0f7385b10685e6acfae645ce3863d69164731cbbc206a"},{"bytes":89,"name":"manifest.sig","sha256":"fae1cb46a01456d591d1313248f572bba3d8a2ea5608ee9e4193857a72807c62"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f505a465b66abb1ca99499215d98eb514f2ed3861a23584a945ec3cd4f14acc9"}],"publication_id":"OT-2026-000089425"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089425
OpenTechnical

OT-2026-000089425

Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7807f4b4476c934ce8fe87ce39ef0d80d613640fbbe5725bce8452632c4796da

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0019]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089425, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089425.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089425" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089425" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089425 Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089425 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0019] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089425 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089425 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089425", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1180 }, "figures": [], "files": [ { "bytes": 19000, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a924abc304421cb14474f72787e812e838def616ff505554cedb2f11cb1eb6b8" }, { "bytes": 8573, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "20d19686c0da552a42cd57d217d9ecdb96dfcf9717761045552a69bd764100eb" }, { "bytes": 8219, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7807f4b4476c934ce8fe87ce39ef0d80d613640fbbe5725bce8452632c4796da" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089425/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089425", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7e8b-91c0-221c34051be0" } 1crw66fH0b0q5nf4Nt/Uz2dD04GzKPufAFEtyDf1mbXukw0F/4KQMC2IFi7NEIINCP4J/zuqrv7qZyx/I4D7Cg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 1crw66fH0b0q5nf4Nt/Uz2dD04GzKPufAFEtyDf1mbXukw0F/4KQMC2IFi7NEIINCP4J/zuqrv7qZyx/I4D7Cg== {"files":[{"bytes":18747,"name":"index.html","sha256":"6c8b14fe04e6d20e3a62f2b28e021b05dba8163b40cdda50037d9c1e5449d715"},{"bytes":8363,"name":"publication.md","sha256":"66c1170e8ff64add0f970ee1bc059faeff206da78bcf338c28f7706f696d9b23"},{"bytes":8009,"name":"publication.txt","sha256":"014615d286f7cc15f7a5866b9a7b2104dfdbd8af73713d535ed9f9180d995541"},{"bytes":2909,"name":"manifest.json","sha256":"d40999aa8f339c1308ac47519e4478c8b7b6237d2f3b6d559fa409c379353abc"},{"bytes":89,"name":"manifest.sig","sha256":"063cfb175090f1e0210e4562923a8e963747d803d8c73c5da95ae5b314494d50"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ef1213e1f87313e739b3848a93928b58b2907be8db0c9fe6875f774f1f56d5e1"}],"publication_id":"OT-2026-000089426"} Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089426
OpenTechnical

OT-2026-000089426

Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
014615d286f7cc15f7a5866b9a7b2104dfdbd8af73713d535ed9f9180d995541

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0029]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089426, “Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089426.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089426" title: "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089426" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089426 Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089426 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0029] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089426 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089426 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089426", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1145 }, "figures": [], "files": [ { "bytes": 18747, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6c8b14fe04e6d20e3a62f2b28e021b05dba8163b40cdda50037d9c1e5449d715" }, { "bytes": 8363, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "66c1170e8ff64add0f970ee1bc059faeff206da78bcf338c28f7706f696d9b23" }, { "bytes": 8009, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "014615d286f7cc15f7a5866b9a7b2104dfdbd8af73713d535ed9f9180d995541" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089426/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089426", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7c58-883b-cf55645a47d8" } OcVL50pvnVGE2vnUzW/2C0PlSgTdrFUSkWENmc2xNMs/ZH4nf7tjY7Skegp+krxEqzawyFteTPQviov1W8bfBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: OcVL50pvnVGE2vnUzW/2C0PlSgTdrFUSkWENmc2xNMs/ZH4nf7tjY7Skegp+krxEqzawyFteTPQviov1W8bfBQ== {"files":[{"bytes":18383,"name":"index.html","sha256":"06d6f8bff85befb2f6b81e91889e95040f795760e0554f489c96a99050f0b673"},{"bytes":8042,"name":"publication.md","sha256":"10859397e1b7392c559f5c1da8178d1ecfc1fae171989853516c84f3f6919dda"},{"bytes":7697,"name":"publication.txt","sha256":"64417c56fa64c528ecd76ab73335799010a90bb5fcae61492a5cae67a83f5b26"},{"bytes":2883,"name":"manifest.json","sha256":"65979e3f1c18c5a7fbe0ee9c5a3056b41fcf9fbeb7eb0b40726697523365f141"},{"bytes":89,"name":"manifest.sig","sha256":"0cdfc2c98e945171373ce0d0ac6568290cfa4d40e2c6f14ea5fdee16f30d731c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c32ba15cbaa6f79315603e4621e06f4712bd8b631c59a73dc3a5fce95a145b7d"}],"publication_id":"OT-2026-000089427"} Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089427
OpenTechnical

OT-2026-000089427

Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
64417c56fa64c528ecd76ab73335799010a90bb5fcae61492a5cae67a83f5b26

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The blow-off valve is fed from the compressed air supply of the cell.

[0018]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0019]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0020]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0021]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0022]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0023]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0024]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0025]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0026]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0027]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0028]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089427, “Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089427.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089427" title: "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089427" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089427 Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089427 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has two outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The blow-off valve is fed from the compressed air supply of the cell. [0018] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0019] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0020] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0021] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0022] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0023] - The workpiece is held until the blow-off valve has opened the circuit. [0024] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0025] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: two (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0026] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0027] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0028] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089427 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089427 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089427", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1114 }, "figures": [], "files": [ { "bytes": 18383, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "06d6f8bff85befb2f6b81e91889e95040f795760e0554f489c96a99050f0b673" }, { "bytes": 8042, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "10859397e1b7392c559f5c1da8178d1ecfc1fae171989853516c84f3f6919dda" }, { "bytes": 7697, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "64417c56fa64c528ecd76ab73335799010a90bb5fcae61492a5cae67a83f5b26" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089427/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089427", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, two outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-75da-a787-3349edf6c842" } +R/B6TPpquG6U6JM8dLbwGA45/0fpZyG5Cj0BxICVygPtA0mvZSQX7wAh+puyMqb6hh/YP466g45KGp5e42NCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: +R/B6TPpquG6U6JM8dLbwGA45/0fpZyG5Cj0BxICVygPtA0mvZSQX7wAh+puyMqb6hh/YP466g45KGp5e42NCA== {"files":[{"bytes":19171,"name":"index.html","sha256":"54351ed8e7e9797ad8d275a4140808894c06fab9bdbc0f7f3c75103602c02f07"},{"bytes":8647,"name":"publication.md","sha256":"7c545030918d41429fcdc8658112cd7c2edea1d8075049e6e54e8397728860c0"},{"bytes":8316,"name":"publication.txt","sha256":"6214eef256f4e848e06908fee316d8eb3cf63bfa9f5904c1c707b8dfd61d3d0f"},{"bytes":2843,"name":"manifest.json","sha256":"65490c5454dc11fb3c9cf1aff4aada0a0abd08c012223bd46544405271d4d847"},{"bytes":89,"name":"manifest.sig","sha256":"9eb265a7b912caf3a5954951485891bd3b0c6282ad0cc8a41c6fcc8f506ea88e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ed755f84452b827233704f72ebc2268f98fb49d1861486f91af7d55e78a3cda0"}],"publication_id":"OT-2026-000089428"} Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089428
OpenTechnical

OT-2026-000089428

Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
6214eef256f4e848e06908fee316d8eb3cf63bfa9f5904c1c707b8dfd61d3d0f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089428, “Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089428.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089428" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089428" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089428 Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089428 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089428 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089428 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089428", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1213 }, "figures": [], "files": [ { "bytes": 19171, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "54351ed8e7e9797ad8d275a4140808894c06fab9bdbc0f7f3c75103602c02f07" }, { "bytes": 8647, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7c545030918d41429fcdc8658112cd7c2edea1d8075049e6e54e8397728860c0" }, { "bytes": 8316, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "6214eef256f4e848e06908fee316d8eb3cf63bfa9f5904c1c707b8dfd61d3d0f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089428/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089428", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7d46-a691-802bc238ca9e" } JvbUobEK1epgK4UuDuFKZQLwPbkik2Z9vGDqg7lbzLro7azFC9qX52/Z4/awIpcjtJD2l0i+oFvOS3xFQ6thDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: JvbUobEK1epgK4UuDuFKZQLwPbkik2Z9vGDqg7lbzLro7azFC9qX52/Z4/awIpcjtJD2l0i+oFvOS3xFQ6thDg== {"files":[{"bytes":18555,"name":"index.html","sha256":"e2e940db6ea13e79d01d67edce76df3c47c4f5136eb9303a541a3aeacde17b85"},{"bytes":8102,"name":"publication.md","sha256":"f6dea93d72e5f84c8e0318530dfacbb5788a998ce1c3a2caa395a274872bb6fa"},{"bytes":7777,"name":"publication.txt","sha256":"3319ccaa53d9995ae24eaf08dfd0b97f22a1ecb48e1abddf4d1665f55b8701a7"},{"bytes":2831,"name":"manifest.json","sha256":"80840111ad3a054ac0c7accd136cc45ffe505d9d248ccbac4348b1077072f811"},{"bytes":89,"name":"manifest.sig","sha256":"b991dc54f45edbbd0591199ffb3b670e7f871b535b9d87c7f231a3cddca40ee9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"92ddcfb29db02fe1855a1178bfd4bf7d72cbba1abf37c014fd8e798fc596dd09"}],"publication_id":"OT-2026-000089429"} Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089429
OpenTechnical

OT-2026-000089429

Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
3319ccaa53d9995ae24eaf08dfd0b97f22a1ecb48e1abddf4d1665f55b8701a7

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089429, “Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089429.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089429" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089429" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089429 Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089429 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089429 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089429 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089429", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1127 }, "figures": [], "files": [ { "bytes": 18555, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "e2e940db6ea13e79d01d67edce76df3c47c4f5136eb9303a541a3aeacde17b85" }, { "bytes": 8102, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f6dea93d72e5f84c8e0318530dfacbb5788a998ce1c3a2caa395a274872bb6fa" }, { "bytes": 7777, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3319ccaa53d9995ae24eaf08dfd0b97f22a1ecb48e1abddf4d1665f55b8701a7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089429/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089429", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-794f-ae66-ecd69b74d9d0" } 9J86s9h5wi9DfklU9PCyKV1686JcHHXqN3yBR4fjy9S8jOGNnk9y39IaxiHSPkLta+RjVkplLBoCDNO9Y1gRBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 9J86s9h5wi9DfklU9PCyKV1686JcHHXqN3yBR4fjy9S8jOGNnk9y39IaxiHSPkLta+RjVkplLBoCDNO9Y1gRBw== {"files":[{"bytes":19370,"name":"index.html","sha256":"52b6ffadb280e482b847c9631dfa4464454f1740114e331ef3c5cac10d8d7319"},{"bytes":8803,"name":"publication.md","sha256":"bf5f0860e5fbe636c4545611fc529aaca900b5b397e57192bb049a1cdba31f9f"},{"bytes":8472,"name":"publication.txt","sha256":"8ec6b9e4f8c173090bc82066b98b3a51b90da98267074ad4c8fe73ca7e64fec8"},{"bytes":2843,"name":"manifest.json","sha256":"c4be3fc02609c62e962c348e5a7ecf0d15317c993c0be4e11b9ee886ea48cb59"},{"bytes":89,"name":"manifest.sig","sha256":"b6827f633afe9b3e4c087c5fb4f24417ce81f35ff9939f90d8b90232c10d8f0a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2b79d814f00b67aeef55eb68bbd740d6752127a4780febe7d08f21dbb41a3fcf"}],"publication_id":"OT-2026-000089430"} Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089430
OpenTechnical

OT-2026-000089430

Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8ec6b9e4f8c173090bc82066b98b3a51b90da98267074ad4c8fe73ca7e64fec8

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089430, “Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089430.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089430" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089430" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089430 Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089430 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089430 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089430 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089430", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1233 }, "figures": [], "files": [ { "bytes": 19370, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "52b6ffadb280e482b847c9631dfa4464454f1740114e331ef3c5cac10d8d7319" }, { "bytes": 8803, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "bf5f0860e5fbe636c4545611fc529aaca900b5b397e57192bb049a1cdba31f9f" }, { "bytes": 8472, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8ec6b9e4f8c173090bc82066b98b3a51b90da98267074ad4c8fe73ca7e64fec8" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089430/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089430", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7442-8226-11e24f9e70b1" } UhjdqcYihg3RgUjyPNr3jL3lFSTWTauIZiIZVoR9axMPcHsR2KJw6k5eJ+eUdWcnXJe3QrhvHDDncHAamJnhBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: UhjdqcYihg3RgUjyPNr3jL3lFSTWTauIZiIZVoR9axMPcHsR2KJw6k5eJ+eUdWcnXJe3QrhvHDDncHAamJnhBA== {"files":[{"bytes":19117,"name":"index.html","sha256":"c61f4e3b7b1ff1ea53b0ea9becee402c482bd4534f8868dfc4c616aef48e19de"},{"bytes":8593,"name":"publication.md","sha256":"13d9dea0519c6feb524e07a484f4a8a326473a98d5f987934a2149365eeaa9e8"},{"bytes":8262,"name":"publication.txt","sha256":"ccb44e7ff0453bbf48a1fefce05663a14a73edae5a89a48dbce0cdc9b9924c6e"},{"bytes":2843,"name":"manifest.json","sha256":"c116a08c1c5a545bb818dba1786f34a48baec7db02ec2f35fd9f79b6f7110b61"},{"bytes":89,"name":"manifest.sig","sha256":"b10db57734282fb345dfc09267c7db8ba53c4957668f6212606bbacb72d01df6"},{"bytes":227,"name":"manifest.sig.txt","sha256":"daf955eb6f082001472796af706264945ebfa4fe2459957bb94bab52db010a90"}],"publication_id":"OT-2026-000089431"} Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089431
OpenTechnical

OT-2026-000089431

Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
ccb44e7ff0453bbf48a1fefce05663a14a73edae5a89a48dbce0cdc9b9924c6e

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089431, “Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089431.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089431" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089431" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089431 Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089431 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089431 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089431 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089431", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1198 }, "figures": [], "files": [ { "bytes": 19117, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c61f4e3b7b1ff1ea53b0ea9becee402c482bd4534f8868dfc4c616aef48e19de" }, { "bytes": 8593, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "13d9dea0519c6feb524e07a484f4a8a326473a98d5f987934a2149365eeaa9e8" }, { "bytes": 8262, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "ccb44e7ff0453bbf48a1fefce05663a14a73edae5a89a48dbce0cdc9b9924c6e" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089431/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089431", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7329-a7e4-4f927a826c42" } YxT6fDLhpXQIe9QVzmDc4uW4ApmZAjS1TiAd2hEMixZzGIVU0poaE6o/uDvTb1lrSfX2a0KLhFYdpJkxHTpzCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: YxT6fDLhpXQIe9QVzmDc4uW4ApmZAjS1TiAd2hEMixZzGIVU0poaE6o/uDvTb1lrSfX2a0KLhFYdpJkxHTpzCA== {"files":[{"bytes":18309,"name":"index.html","sha256":"516e6cb35eaef9e1253a49b3995a7c869355e9959d80048064993bfddd3a3b9c"},{"bytes":7904,"name":"publication.md","sha256":"ddb7ffc922773c0fea2a61c9185083baa2cb27f2f2a4223efc85dc33f661a6c1"},{"bytes":7577,"name":"publication.txt","sha256":"fc13ad473ccfdf93ee859fef48a2e9aa0d806124597cc83ca1c3189173c89f14"},{"bytes":2844,"name":"manifest.json","sha256":"c42dce53e0387ef0b2f587a43a2d4e7416f853eaa64c0a7c47cf3c0ac2a80f66"},{"bytes":89,"name":"manifest.sig","sha256":"b945097800f218c19ad16a8273714f0af5ee0b06cafb930bfb35e1ed4f8bf676"},{"bytes":227,"name":"manifest.sig.txt","sha256":"5f4b6f87195f21188799d789404944ac76250ac51901e654c712138871a6da08"}],"publication_id":"OT-2026-000089432"} Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089432
OpenTechnical

OT-2026-000089432

Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
fc13ad473ccfdf93ee859fef48a2e9aa0d806124597cc83ca1c3189173c89f14

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089432, “Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089432.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089432" title: "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089432" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089432 Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089432 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089432 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089432 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089432", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1090 }, "figures": [], "files": [ { "bytes": 18309, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "516e6cb35eaef9e1253a49b3995a7c869355e9959d80048064993bfddd3a3b9c" }, { "bytes": 7904, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ddb7ffc922773c0fea2a61c9185083baa2cb27f2f2a4223efc85dc33f661a6c1" }, { "bytes": 7577, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fc13ad473ccfdf93ee859fef48a2e9aa0d806124597cc83ca1c3189173c89f14" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089432/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089432", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7ca4-9c21-5cb948a4ae94" } O77dzVa/gYA8rm+rIZpja/tZMsCOgLE5XgBJhbfi/BxutrD+N/cC+SEElQoSTTyya3CJvce/iO6piOim6eoLBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: O77dzVa/gYA8rm+rIZpja/tZMsCOgLE5XgBJhbfi/BxutrD+N/cC+SEElQoSTTyya3CJvce/iO6piOim6eoLBw== {"files":[{"bytes":19124,"name":"index.html","sha256":"203a94caf7effc3820c7d09a5858ce908a921b60691b7b50693944737c217b4a"},{"bytes":8605,"name":"publication.md","sha256":"ca82575e167f82fb3f8c3070dc1fc63980495e142b2c7f1653c2c4619534d4fd"},{"bytes":8272,"name":"publication.txt","sha256":"1a46b67da51ad28f8b98ca69cf7c0bb538e37786cd10fa212f302815a5be4f86"},{"bytes":2856,"name":"manifest.json","sha256":"39594855d6250553e50f15718cd4c51144864a6ffb417f29738e53a7db39a77a"},{"bytes":89,"name":"manifest.sig","sha256":"cf421540ef28fab9fe02bf29e09f98fc9d468cf3fa55c0c814f31f8fb048eaf2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"992454412bb7fdb6ff00b94a859e41f78da06e03a5cf22eb62a8aa5a959aebac"}],"publication_id":"OT-2026-000089433"} Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089433
OpenTechnical

OT-2026-000089433

Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
1a46b67da51ad28f8b98ca69cf7c0bb538e37786cd10fa212f302815a5be4f86

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089433, “Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089433.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089433" title: "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089433" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089433 Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089433 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089433 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089433 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089433", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1196 }, "figures": [], "files": [ { "bytes": 19124, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "203a94caf7effc3820c7d09a5858ce908a921b60691b7b50693944737c217b4a" }, { "bytes": 8605, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ca82575e167f82fb3f8c3070dc1fc63980495e142b2c7f1653c2c4619534d4fd" }, { "bytes": 8272, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1a46b67da51ad28f8b98ca69cf7c0bb538e37786cd10fa212f302815a5be4f86" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089433/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089433", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7546-8421-1da00d09fc59" } 41Bxmv3u4fNFPbPnKjRhyVDxxAtKWSp4nNoEqS+WIj2JSccY1pBXzIscs9byXuqErvYmh1xm+FQEkuXCMKLgCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 41Bxmv3u4fNFPbPnKjRhyVDxxAtKWSp4nNoEqS+WIj2JSccY1pBXzIscs9byXuqErvYmh1xm+FQEkuXCMKLgCQ== {"files":[{"bytes":18871,"name":"index.html","sha256":"09a78978a4351f65e13328adf0c4a6fc8488dab92ee24c205ba095d2932f3e17"},{"bytes":8395,"name":"publication.md","sha256":"a88ac109c938a3ec8a7be9157ae0d03a57c943391ecfa9998883f707c4807006"},{"bytes":8062,"name":"publication.txt","sha256":"9e43c5d7e83ca241e899eaad7a3ad732d077c0b551df5f56cdfad3164ee49d81"},{"bytes":2856,"name":"manifest.json","sha256":"351bb71ecf2210824b4b545e7e93ef9af0dbae9786cab2b1fb2577caf47e7074"},{"bytes":89,"name":"manifest.sig","sha256":"57ec43a97b8b668ee841496b0403c0f84132c5c37aca234b13b54f62f4126e59"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8f64745d45ed83d895111900e89c5596121373da37405e1c4a6fcebc39c9eec8"}],"publication_id":"OT-2026-000089434"} Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089434
OpenTechnical

OT-2026-000089434

Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
9e43c5d7e83ca241e899eaad7a3ad732d077c0b551df5f56cdfad3164ee49d81

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089434, “Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089434.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089434" title: "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089434" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089434 Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089434 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089434 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089434 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089434", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1161 }, "figures": [], "files": [ { "bytes": 18871, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "09a78978a4351f65e13328adf0c4a6fc8488dab92ee24c205ba095d2932f3e17" }, { "bytes": 8395, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a88ac109c938a3ec8a7be9157ae0d03a57c943391ecfa9998883f707c4807006" }, { "bytes": 8062, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9e43c5d7e83ca241e899eaad7a3ad732d077c0b551df5f56cdfad3164ee49d81" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089434/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089434", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7fae-b53a-1bc7aa6af144" } DR1xFMvbOO9o/V+Moht64Aw9tBPR2ndgiNTApWgN4YfSgGgs+UDiVj6xopKFEGvX2YtYxkMRbeV8G9cm/DctAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: DR1xFMvbOO9o/V+Moht64Aw9tBPR2ndgiNTApWgN4YfSgGgs+UDiVj6xopKFEGvX2YtYxkMRbeV8G9cm/DctAQ== {"files":[{"bytes":18309,"name":"index.html","sha256":"7d7073f864a39e934580f003804ede01ce6f6120494dc70e644088c5973ff5e5"},{"bytes":7904,"name":"publication.md","sha256":"1487b0fa2f126d55e1565be379db5b9657dba6cf19c4fe5a7b900c132ecd0381"},{"bytes":7577,"name":"publication.txt","sha256":"c04c0c35dd61a30c2f2fa46176881b590ac3657121132700889399471fd2a157"},{"bytes":2844,"name":"manifest.json","sha256":"7aae0f38d2e299f59541750c276e5425086311f83759c62db4ec7a8f529967ec"},{"bytes":89,"name":"manifest.sig","sha256":"1d8909ccbe6901fc6c94d0c8395d19cd29d8360442dd01d604e32925a3aaa3bd"},{"bytes":227,"name":"manifest.sig.txt","sha256":"dd51c100e02ec216edf9f6b3ea2be947e9b39ca783ad6b29770cd446fbbcb9fb"}],"publication_id":"OT-2026-000089435"} Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089435
OpenTechnical

OT-2026-000089435

Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
c04c0c35dd61a30c2f2fa46176881b590ac3657121132700889399471fd2a157

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089435, “Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089435.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089435" title: "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089435" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089435 Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089435 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089435 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089435 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089435", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1090 }, "figures": [], "files": [ { "bytes": 18309, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7d7073f864a39e934580f003804ede01ce6f6120494dc70e644088c5973ff5e5" }, { "bytes": 7904, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1487b0fa2f126d55e1565be379db5b9657dba6cf19c4fe5a7b900c132ecd0381" }, { "bytes": 7577, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c04c0c35dd61a30c2f2fa46176881b590ac3657121132700889399471fd2a157" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089435/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089435", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-78d7-9987-a84eeb9a6bf8" } EB0qJOuf5v2tCNCV5M5fnlR+mfn2FjIi8QKIw7cCTqz1oseEksDhZD9kNvHRpFSs/1BOCacPUJmJTXASI2k8CA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: EB0qJOuf5v2tCNCV5M5fnlR+mfn2FjIi8QKIw7cCTqz1oseEksDhZD9kNvHRpFSs/1BOCacPUJmJTXASI2k8CA== {"files":[{"bytes":19124,"name":"index.html","sha256":"cd9c0314987b0082646d802219c07b62f015340d1d3f3a7cfd1ecbdaea3c04c7"},{"bytes":8605,"name":"publication.md","sha256":"0d40039515a319bf1720da094cae0329a5a2cf77d4c2d6c519d9387dfae8c8ae"},{"bytes":8272,"name":"publication.txt","sha256":"8a37a5e6909cd8e84e4051e9df9ef46a49439bb6a642f0e488e9f30dcd879d6a"},{"bytes":2856,"name":"manifest.json","sha256":"6eb877299dc3ec569bbe600096dead4e8a4ea315ac60df1f137873d68bbcaab2"},{"bytes":89,"name":"manifest.sig","sha256":"6ac77d5de86559075f0ae9908e6b2a3ce9345b0f96baebcf43e5fc8d8d51c9c7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e7d46b7d15a4dc4f7f662aec265c0ac680827a6725f62181e7bc280812f799e5"}],"publication_id":"OT-2026-000089436"} Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089436
OpenTechnical

OT-2026-000089436

Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8a37a5e6909cd8e84e4051e9df9ef46a49439bb6a642f0e488e9f30dcd879d6a

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089436, “Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089436.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089436" title: "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089436" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089436 Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089436 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089436 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089436 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089436", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1196 }, "figures": [], "files": [ { "bytes": 19124, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "cd9c0314987b0082646d802219c07b62f015340d1d3f3a7cfd1ecbdaea3c04c7" }, { "bytes": 8605, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0d40039515a319bf1720da094cae0329a5a2cf77d4c2d6c519d9387dfae8c8ae" }, { "bytes": 8272, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8a37a5e6909cd8e84e4051e9df9ef46a49439bb6a642f0e488e9f30dcd879d6a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089436/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089436", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7a69-b9f7-279dd1101e30" } CC94j+hp6Sky9t1lIgom7vg6EIIiTFZ5A2R/Mmni8w3eIY3DrIxlAkqB+Y/KxRA/PwoFpKsc1ykg2cjH8aU7BA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: CC94j+hp6Sky9t1lIgom7vg6EIIiTFZ5A2R/Mmni8w3eIY3DrIxlAkqB+Y/KxRA/PwoFpKsc1ykg2cjH8aU7BA== {"files":[{"bytes":18871,"name":"index.html","sha256":"4f683596c476e0e7403df45c4920e24e4de54f79110190bf6e1073e000052ca1"},{"bytes":8395,"name":"publication.md","sha256":"e2db490c5f4ac216883f0160e36e98c7bb7a9b9c77941271caa6dc04400a661b"},{"bytes":8062,"name":"publication.txt","sha256":"2eabf2b657d75e79ec7e4edc3148d1819c58ac77efffb541e57f2fe0ec8911e9"},{"bytes":2856,"name":"manifest.json","sha256":"085e17b3e18bd9f03d41e723f8f3cbc6da5188fef9d2da985bbf2e86e7ba8b97"},{"bytes":89,"name":"manifest.sig","sha256":"d78990dd5d5474bbbd52b15a680708b4610c14c3c73967c9ff357e8c2283e3d8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"cbbc4df923deb05acf5943bb78bd45199e04a1f021a36339f5a9978efd2a258e"}],"publication_id":"OT-2026-000089437"} Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089437
OpenTechnical

OT-2026-000089437

Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
2eabf2b657d75e79ec7e4edc3148d1819c58ac77efffb541e57f2fe0ec8911e9

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089437, “Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089437.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089437" title: "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089437" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089437 Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089437 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089437 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089437 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089437", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1161 }, "figures": [], "files": [ { "bytes": 18871, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4f683596c476e0e7403df45c4920e24e4de54f79110190bf6e1073e000052ca1" }, { "bytes": 8395, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e2db490c5f4ac216883f0160e36e98c7bb7a9b9c77941271caa6dc04400a661b" }, { "bytes": 8062, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2eabf2b657d75e79ec7e4edc3148d1819c58ac77efffb541e57f2fe0ec8911e9" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089437/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089437", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7c35-a1d4-91a7af10f27c" } F71mjpedFX4VCTKMClZcfxDzbkVh2xVpztt2+zVqchtcLgpleO4EmtJddsgkubxZFF/mixQwBZcms5k9AsQRAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: F71mjpedFX4VCTKMClZcfxDzbkVh2xVpztt2+zVqchtcLgpleO4EmtJddsgkubxZFF/mixQwBZcms5k9AsQRAA== {"files":[{"bytes":18427,"name":"index.html","sha256":"82de6cd8bbfac389c6d6eb0d0a0b5969a57ac0892170c35fb4024766f565c6b0"},{"bytes":8002,"name":"publication.md","sha256":"66e5643b3f769dade66367760328e9327cfe88beaeea47cfc952c77926af1828"},{"bytes":7665,"name":"publication.txt","sha256":"e06a2c4fef45cfccee14c61fc0e58f9dad035ceaf7733dad8efd0eced5fb6926"},{"bytes":2854,"name":"manifest.json","sha256":"9d31a461587068dbecc088a7f4b2f91ca54920d98a94d84d9e755cc48682709e"},{"bytes":89,"name":"manifest.sig","sha256":"d9a6e9ec417d8a8334d203415577d2eae61cf4034c7302ddeb3ee2dfed838272"},{"bytes":227,"name":"manifest.sig.txt","sha256":"87919b4d3eef1f2a70179c46a64da00f639e5db5ded005e3425fef9d95e172a7"}],"publication_id":"OT-2026-000089438"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089438
OpenTechnical

OT-2026-000089438

Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
e06a2c4fef45cfccee14c61fc0e58f9dad035ceaf7733dad8efd0eced5fb6926

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089438, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089438.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089438" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089438" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089438 Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089438 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089438 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089438 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089438", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1102 }, "figures": [], "files": [ { "bytes": 18427, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "82de6cd8bbfac389c6d6eb0d0a0b5969a57ac0892170c35fb4024766f565c6b0" }, { "bytes": 8002, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "66e5643b3f769dade66367760328e9327cfe88beaeea47cfc952c77926af1828" }, { "bytes": 7665, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e06a2c4fef45cfccee14c61fc0e58f9dad035ceaf7733dad8efd0eced5fb6926" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089438/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089438", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-751a-9c4b-df449a8da6ee" } qDMpgyUIGGzg5lscTZ52sE1Jc6baLzxLrgRq9JG1wJQUnUMFXuy18VV2qsJsWeb0qaEHiAYWNIWMODAL1/vgBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: qDMpgyUIGGzg5lscTZ52sE1Jc6baLzxLrgRq9JG1wJQUnUMFXuy18VV2qsJsWeb0qaEHiAYWNIWMODAL1/vgBg== {"files":[{"bytes":19242,"name":"index.html","sha256":"2d1b00ec20da30f5620f209873f427f61ebe3d9e966acdbedd52a697e7744d4e"},{"bytes":8703,"name":"publication.md","sha256":"b4a1a6deb395d475f69a2c90cfcce221555a7952fab13e4d8a8c9fea2cbbec3e"},{"bytes":8360,"name":"publication.txt","sha256":"bd15189d31f73d9e48e49b82eeb9fb944bfceaab5c3df6f1fef1163ea4daf329"},{"bytes":2866,"name":"manifest.json","sha256":"6d0241c85607e2e1b302807eaf7bc9c50072a2173354afbeb74c063fef7b071d"},{"bytes":89,"name":"manifest.sig","sha256":"75b2c4b19252d04c38b5f2a046029722688b2d6b213f1e55f8bfa720fc90d44a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e6ae34202792dd627aee2444f635cbc9676c2371bb20c5be6cc71676f71542f7"}],"publication_id":"OT-2026-000089439"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089439
OpenTechnical

OT-2026-000089439

Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
bd15189d31f73d9e48e49b82eeb9fb944bfceaab5c3df6f1fef1163ea4daf329

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089439, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089439.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089439" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089439" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089439 Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089439 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089439 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089439 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089439", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1208 }, "figures": [], "files": [ { "bytes": 19242, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2d1b00ec20da30f5620f209873f427f61ebe3d9e966acdbedd52a697e7744d4e" }, { "bytes": 8703, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b4a1a6deb395d475f69a2c90cfcce221555a7952fab13e4d8a8c9fea2cbbec3e" }, { "bytes": 8360, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "bd15189d31f73d9e48e49b82eeb9fb944bfceaab5c3df6f1fef1163ea4daf329" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089439/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089439", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7d08-88cf-046bfdd424f7" } RF1nU2AbJDNxLoW35rR3MAAdMwHaWYeDHHEwoyeHMNXQOBwhjeRVm2Kds95jpBTawRy12B7ShVoIa+LceOV2Dg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: RF1nU2AbJDNxLoW35rR3MAAdMwHaWYeDHHEwoyeHMNXQOBwhjeRVm2Kds95jpBTawRy12B7ShVoIa+LceOV2Dg== {"files":[{"bytes":18989,"name":"index.html","sha256":"685d58163a71801a446d8f81104d4657e690fee1b8a616ff6ebd05bab6bd5683"},{"bytes":8493,"name":"publication.md","sha256":"38477b72212a34b73e8e292c44de72040908a64e12beba6b32b5c2259a28d6be"},{"bytes":8150,"name":"publication.txt","sha256":"fc4effd8ff5dc56650e4aa597b65b40e973fa49575184651c61a39998f53979e"},{"bytes":2866,"name":"manifest.json","sha256":"aefa2124913e7871ae308fce7d59a992cf4a127d132391065f8f4835024d3585"},{"bytes":89,"name":"manifest.sig","sha256":"42393a1d95ef4480584a1bc0bdd9432b83b9993ce659f0f17b1379cb95f7f56d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"12cfe89e598e55daebeeccef3bafdc20c0aa98260ad4c6adbaad2895eef63378"}],"publication_id":"OT-2026-000089440"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089440
OpenTechnical

OT-2026-000089440

Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
fc4effd8ff5dc56650e4aa597b65b40e973fa49575184651c61a39998f53979e

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089440, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089440.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089440" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089440" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089440 Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089440 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089440 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089440 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089440", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1173 }, "figures": [], "files": [ { "bytes": 18989, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "685d58163a71801a446d8f81104d4657e690fee1b8a616ff6ebd05bab6bd5683" }, { "bytes": 8493, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "38477b72212a34b73e8e292c44de72040908a64e12beba6b32b5c2259a28d6be" }, { "bytes": 8150, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fc4effd8ff5dc56650e4aa597b65b40e973fa49575184651c61a39998f53979e" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089440/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089440", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-75b8-ad05-8f0da0cc42fd" } VqniE2GC+RPeIXzyrRk8I7qJiSUa3PKlDp5MH7TqENxvlfIma8h+Nix7L+U8CdJ1swMPANFdLBph7ilfYMvJDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: VqniE2GC+RPeIXzyrRk8I7qJiSUa3PKlDp5MH7TqENxvlfIma8h+Nix7L+U8CdJ1swMPANFdLBph7ilfYMvJDA== {"files":[{"bytes":18428,"name":"index.html","sha256":"1940db5e3ff2abdc7270032b6955abb70437e7333d45c66b9d2009e0980b22f1"},{"bytes":8003,"name":"publication.md","sha256":"7c917ec39fe842d6a06cb0fe067b9e5ac14d6ad4a254fa6a5153740c21a0db20"},{"bytes":7666,"name":"publication.txt","sha256":"3dd6529901d646bd81bfba77f7103facf64c834860613ebd7a5072186cc20dd7"},{"bytes":2854,"name":"manifest.json","sha256":"b69660b31fa1db31835a1eca99e91b7948f99c1e30989aa1cf75729870746c54"},{"bytes":89,"name":"manifest.sig","sha256":"a450e73d57da534f9f3436eabc8ff10d40817a085217a2039a3bee8336c9fad2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2b38d9d5cfb1069932ec20ff0e1231f02e56a9b7ce776a4716c4b77afbd65b44"}],"publication_id":"OT-2026-000089441"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089441
OpenTechnical

OT-2026-000089441

Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
3dd6529901d646bd81bfba77f7103facf64c834860613ebd7a5072186cc20dd7

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089441, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089441.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089441" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089441" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089441 Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089441 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089441 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089441 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089441", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1102 }, "figures": [], "files": [ { "bytes": 18428, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1940db5e3ff2abdc7270032b6955abb70437e7333d45c66b9d2009e0980b22f1" }, { "bytes": 8003, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7c917ec39fe842d6a06cb0fe067b9e5ac14d6ad4a254fa6a5153740c21a0db20" }, { "bytes": 7666, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3dd6529901d646bd81bfba77f7103facf64c834860613ebd7a5072186cc20dd7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089441/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089441", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7de5-85b1-8ed5acbc6c98" } xB2RLn9bqiU1C846i6b8Yv6+YkmHP2awCR0jL7PbF60bOlPjRfhjLZP8ZI0Nn0o7JQAaG8qw+/RUhQR/1nJGCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: xB2RLn9bqiU1C846i6b8Yv6+YkmHP2awCR0jL7PbF60bOlPjRfhjLZP8ZI0Nn0o7JQAaG8qw+/RUhQR/1nJGCw== {"files":[{"bytes":19243,"name":"index.html","sha256":"6a661b2711099869b9b69c9b863980b07268000c02559f30b81e3e2a0f1b25d7"},{"bytes":8704,"name":"publication.md","sha256":"7de1fdacfc5fcbf3588726b05c34d21cdf06606b3fc3782f771e6dc41f5a93a5"},{"bytes":8361,"name":"publication.txt","sha256":"39d83fe26c6b62d2e20fa2e19729280ed5694cf35e7f35991551bc1d037f66f0"},{"bytes":2866,"name":"manifest.json","sha256":"e1532efb34e8ff7ff2eb06de0bd8914c225e8aed5731620c493ad7ccf96adf2e"},{"bytes":89,"name":"manifest.sig","sha256":"309fd8632577335f27af5492d2b8e8f732a347765cfb82f050852e22759ba109"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d7da0d7c55fbb38397cb17e15c476f4fff1415664831482961d03b014fba08dd"}],"publication_id":"OT-2026-000089442"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089442
OpenTechnical

OT-2026-000089442

Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
39d83fe26c6b62d2e20fa2e19729280ed5694cf35e7f35991551bc1d037f66f0

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089442, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089442.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089442" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089442" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089442 Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089442 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089442 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089442 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089442", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1208 }, "figures": [], "files": [ { "bytes": 19243, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6a661b2711099869b9b69c9b863980b07268000c02559f30b81e3e2a0f1b25d7" }, { "bytes": 8704, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7de1fdacfc5fcbf3588726b05c34d21cdf06606b3fc3782f771e6dc41f5a93a5" }, { "bytes": 8361, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "39d83fe26c6b62d2e20fa2e19729280ed5694cf35e7f35991551bc1d037f66f0" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089442/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089442", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-70f4-83bc-4d1c58bdfa56" } NWTHzIEEyzZCfpOUIPh8FpGmhrl06j/9qJcp1MYVnOIfMvQG0TrhvneWsPF9xhZFDDN8AChq3sDeOqHTPHr2Cw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: NWTHzIEEyzZCfpOUIPh8FpGmhrl06j/9qJcp1MYVnOIfMvQG0TrhvneWsPF9xhZFDDN8AChq3sDeOqHTPHr2Cw== {"files":[{"bytes":18990,"name":"index.html","sha256":"28b698a3fe3a3492d3bf37fff7e7194718d366a08ef93481ed5958d1a79d6893"},{"bytes":8494,"name":"publication.md","sha256":"5087e69ec4313997a18f1b3fc967dc9102cb4029c994d355dba0eed97f1eb35d"},{"bytes":8151,"name":"publication.txt","sha256":"c50d3240cd58a70c29df4cadf5754d507453f4edef87928403f9e3a368c8a3d9"},{"bytes":2866,"name":"manifest.json","sha256":"c583efb3f530e6132435520dd65cbf3b5529111a859a4e9c58bd78a35d024e3b"},{"bytes":89,"name":"manifest.sig","sha256":"7913af0f36596a8146333bd5f529d68ff85c4dbff7b89f6515b498c4ce4463d3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"adce200f8483e9c901c8827cca017ef4649716d35be205d73a447657593631c5"}],"publication_id":"OT-2026-000089443"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089443
OpenTechnical

OT-2026-000089443

Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c50d3240cd58a70c29df4cadf5754d507453f4edef87928403f9e3a368c8a3d9

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089443, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089443.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089443" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089443" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089443 Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089443 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089443 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089443 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089443", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1173 }, "figures": [], "files": [ { "bytes": 18990, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "28b698a3fe3a3492d3bf37fff7e7194718d366a08ef93481ed5958d1a79d6893" }, { "bytes": 8494, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5087e69ec4313997a18f1b3fc967dc9102cb4029c994d355dba0eed97f1eb35d" }, { "bytes": 8151, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c50d3240cd58a70c29df4cadf5754d507453f4edef87928403f9e3a368c8a3d9" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089443/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089443", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7e38-a465-d0821362d25d" } MpzVvHi8RTsO8k5G6x8qXQAXskGM7Fw+7K15qSoJ+C9BGIONG9rLI9rDC3N36qTWFX3XIBXKwq5/OXfEIlMxDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: MpzVvHi8RTsO8k5G6x8qXQAXskGM7Fw+7K15qSoJ+C9BGIONG9rLI9rDC3N36qTWFX3XIBXKwq5/OXfEIlMxDA== {"files":[{"bytes":18432,"name":"index.html","sha256":"ae4b5c31000ed43f566ca8a8c3f543d8e84c23bee6ebfbefcac78003b9ca21fc"},{"bytes":8007,"name":"publication.md","sha256":"887f033353d137afcc3066ed436ebaec80eb8e549e8d8753ac3728c52e8512f1"},{"bytes":7670,"name":"publication.txt","sha256":"defdcc5c7df1664b107d85658822e6da8d4639487dcdb017637faee6abe71d88"},{"bytes":2854,"name":"manifest.json","sha256":"550f6e67a638e1740e5553b4d468123e2a4dec24cc848348ab7cca72280b6ab6"},{"bytes":89,"name":"manifest.sig","sha256":"169bc857439619b858ca3eaa0c73b939ece0d2f53679784331acd66ddc4ee1ad"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c7311c2ff515fbbfb61412d3b26b67302261a52b45e78655bcfaa3e67b096f77"}],"publication_id":"OT-2026-000089444"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089444
OpenTechnical

OT-2026-000089444

Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
defdcc5c7df1664b107d85658822e6da8d4639487dcdb017637faee6abe71d88

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089444, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089444.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089444" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089444" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089444 Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089444 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089444 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089444 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089444", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1102 }, "figures": [], "files": [ { "bytes": 18432, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ae4b5c31000ed43f566ca8a8c3f543d8e84c23bee6ebfbefcac78003b9ca21fc" }, { "bytes": 8007, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "887f033353d137afcc3066ed436ebaec80eb8e549e8d8753ac3728c52e8512f1" }, { "bytes": 7670, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "defdcc5c7df1664b107d85658822e6da8d4639487dcdb017637faee6abe71d88" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089444/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089444", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-75cf-88b2-56261a8e688a" } eKjQPaFWKITfzwGfkzOKULHb78DusUqjk+GIh8b7Kazxqx2RsXe1lAdfdFFFFUwwpc2qNHhcZHUUVIhAp14kAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: eKjQPaFWKITfzwGfkzOKULHb78DusUqjk+GIh8b7Kazxqx2RsXe1lAdfdFFFFUwwpc2qNHhcZHUUVIhAp14kAQ== {"files":[{"bytes":19247,"name":"index.html","sha256":"69bbc5c415175aa63775c77b045fa04f7895b8a59bc5cb6a2b71d4017d118664"},{"bytes":8708,"name":"publication.md","sha256":"6c8bc342b1be1038d921005467c83f42c10f8cd20d4483e27453c2db1f055003"},{"bytes":8365,"name":"publication.txt","sha256":"db5e6c6b4ece6dbef309e964ae82b3d6f2acf2611d90f340506c40ad7e7adf74"},{"bytes":2866,"name":"manifest.json","sha256":"ac9b7afb7a6a2e21893badbeacd389ba890aeda47aa28848860369db1c9a1c12"},{"bytes":89,"name":"manifest.sig","sha256":"143b5afb7125b293655e9289da940d9e5835f9b5c705c50d5bef741f837e3b17"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f70455fbd471ac5f788d7fe9310f1fc39e532b263cbcd06430c81c85733d9eb9"}],"publication_id":"OT-2026-000089445"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089445
OpenTechnical

OT-2026-000089445

Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
db5e6c6b4ece6dbef309e964ae82b3d6f2acf2611d90f340506c40ad7e7adf74

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089445, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089445.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089445" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089445" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089445 Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089445 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089445 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089445 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089445", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1208 }, "figures": [], "files": [ { "bytes": 19247, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "69bbc5c415175aa63775c77b045fa04f7895b8a59bc5cb6a2b71d4017d118664" }, { "bytes": 8708, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "6c8bc342b1be1038d921005467c83f42c10f8cd20d4483e27453c2db1f055003" }, { "bytes": 8365, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "db5e6c6b4ece6dbef309e964ae82b3d6f2acf2611d90f340506c40ad7e7adf74" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089445/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089445", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7ced-a99a-1c055f464bc2" } PCeC8B/0dPmQmt9mJoFPrsZCzE9qK6+PdzJOtkMgjAsX9K0J8Ql63KdGxvV4E4/4i+8LL5Sb8thkpoY79gIHBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: PCeC8B/0dPmQmt9mJoFPrsZCzE9qK6+PdzJOtkMgjAsX9K0J8Ql63KdGxvV4E4/4i+8LL5Sb8thkpoY79gIHBg== {"files":[{"bytes":18994,"name":"index.html","sha256":"a98352a10755acdfa4c0691c57a01b932468759fe4bc723e52543d66c3aeeb9d"},{"bytes":8498,"name":"publication.md","sha256":"cb955981e7870bb26bb3f6218eac716a11d906801881a111d0cb596226010422"},{"bytes":8155,"name":"publication.txt","sha256":"c7e67c7dfe831fc19dcafdfc166a097318062ae68a642a2206aefbdf717870f2"},{"bytes":2866,"name":"manifest.json","sha256":"f1a041ff83f29bb4ba641285c95741a3b8c30e5a5e1778c53666fa71e94477a4"},{"bytes":89,"name":"manifest.sig","sha256":"2da9b8397a09799026eab01693695124b9db0d06f764e36b6e6a92d3137eb688"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f2121c7ba34a28577600c94c33584a1364605d3938211862c5a8e3bd53712b53"}],"publication_id":"OT-2026-000089446"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089446
OpenTechnical

OT-2026-000089446

Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c7e67c7dfe831fc19dcafdfc166a097318062ae68a642a2206aefbdf717870f2

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089446, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089446.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089446" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089446" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089446 Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089446 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089446 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089446 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089446", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1173 }, "figures": [], "files": [ { "bytes": 18994, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a98352a10755acdfa4c0691c57a01b932468759fe4bc723e52543d66c3aeeb9d" }, { "bytes": 8498, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cb955981e7870bb26bb3f6218eac716a11d906801881a111d0cb596226010422" }, { "bytes": 8155, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c7e67c7dfe831fc19dcafdfc166a097318062ae68a642a2206aefbdf717870f2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089446/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089446", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-735d-8afa-97474a19f86c" } 8Y2qnV4pfcQqfC+wDYR96RdMFKbKNsBCkvzNPMH1tztxwJbM3GgEWk/mTUT51VYOjkOPyWUOcXjY9Tap1QhSAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 8Y2qnV4pfcQqfC+wDYR96RdMFKbKNsBCkvzNPMH1tztxwJbM3GgEWk/mTUT51VYOjkOPyWUOcXjY9Tap1QhSAA== {"files":[{"bytes":18621,"name":"index.html","sha256":"880c0e1658036b161316c41d30962cd030a37bfa90fac03a8f317f018ecfe5d3"},{"bytes":8164,"name":"publication.md","sha256":"c4895133ff4fbf978d62c7fe911fdf867fef0a64bcf0337d02c10aa90d99f15a"},{"bytes":7837,"name":"publication.txt","sha256":"409a445068d626597d79dfb1889271337ff4c9b7e011c5edb426fd90d2faae59"},{"bytes":2833,"name":"manifest.json","sha256":"7ce8d265d2b5939e4198d34a222afd8508b89f4524cc0b75828ae33892d392e1"},{"bytes":89,"name":"manifest.sig","sha256":"10df4303cbd970b9a7b8b993e9dbc621467e9f1fb1a982fc1acfbec8e36219b7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1e03cab9359ea2ddf442ffb8af2eec4dd5a06a5327a75f7ee5b2a64a328473d6"}],"publication_id":"OT-2026-000089447"} Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089447
OpenTechnical

OT-2026-000089447

Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
409a445068d626597d79dfb1889271337ff4c9b7e011c5edb426fd90d2faae59

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089447, “Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089447.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089447" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089447" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089447 Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089447 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089447 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089447 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089447", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1142 }, "figures": [], "files": [ { "bytes": 18621, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "880c0e1658036b161316c41d30962cd030a37bfa90fac03a8f317f018ecfe5d3" }, { "bytes": 8164, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c4895133ff4fbf978d62c7fe911fdf867fef0a64bcf0337d02c10aa90d99f15a" }, { "bytes": 7837, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "409a445068d626597d79dfb1889271337ff4c9b7e011c5edb426fd90d2faae59" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089447/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089447", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-778e-a0cc-c3152b0d1fc4" } VxdHg/py6jmLsr86J9otvWqq4JpjYVc9+0v7kzX0H7Z6O3MDg0JtDM+UIsxJFO4KL1kCLb6rJP9ThvMWYLBhAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: VxdHg/py6jmLsr86J9otvWqq4JpjYVc9+0v7kzX0H7Z6O3MDg0JtDM+UIsxJFO4KL1kCLb6rJP9ThvMWYLBhAw== {"files":[{"bytes":19436,"name":"index.html","sha256":"30a7b63faa7cc0be4b9081850a490fa0c8c9f42d761317f5dd3bbbcad25b2edc"},{"bytes":8865,"name":"publication.md","sha256":"939bfd36d771baabeb2dfb4b6ef1f2ea46a6bd874ea3b93f71feae94529e3323"},{"bytes":8532,"name":"publication.txt","sha256":"36c78a2938cb13b88937ef7890e716182597f5c1d068d6bcbaad43f3aa52fb5a"},{"bytes":2845,"name":"manifest.json","sha256":"108d6470ce184680053786721a0fbd5659133427578c3851d4f7f819f905f12c"},{"bytes":89,"name":"manifest.sig","sha256":"7d9d1322336770cfc20abc292be3217c07c872e6abde0728cdeb441ecc8b9301"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f2aa3d5a96393df2aed603338a5c67284ec59f3c73fc7ef7ff117293dc1ecbbd"}],"publication_id":"OT-2026-000089448"} Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089448
OpenTechnical

OT-2026-000089448

Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
36c78a2938cb13b88937ef7890e716182597f5c1d068d6bcbaad43f3aa52fb5a

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089448, “Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089448.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089448" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089448" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089448 Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089448 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089448 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089448 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089448", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1248 }, "figures": [], "files": [ { "bytes": 19436, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "30a7b63faa7cc0be4b9081850a490fa0c8c9f42d761317f5dd3bbbcad25b2edc" }, { "bytes": 8865, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "939bfd36d771baabeb2dfb4b6ef1f2ea46a6bd874ea3b93f71feae94529e3323" }, { "bytes": 8532, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "36c78a2938cb13b88937ef7890e716182597f5c1d068d6bcbaad43f3aa52fb5a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089448/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089448", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-75b9-ac7a-dde5a39596f7" } kvQ8WjYeTp41ISWsnwOhYVELrQrqEYEKh0pdk660wOIBs2LHO/tLv8nvEW0X3++MtlWUflRSudubGQZZFJfzDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: kvQ8WjYeTp41ISWsnwOhYVELrQrqEYEKh0pdk660wOIBs2LHO/tLv8nvEW0X3++MtlWUflRSudubGQZZFJfzDg== {"files":[{"bytes":19183,"name":"index.html","sha256":"20ef48cdb73897e3d6b8430568e3827f6fdfc186a33a32e6aee57100f1290180"},{"bytes":8655,"name":"publication.md","sha256":"520bf7f36990601af59f2c1376ede953daf1861ac1158d9f79e082bd0e2eb432"},{"bytes":8322,"name":"publication.txt","sha256":"444e41e176ad47b3208053f2250d5b9e9258cc23dfba03bf7a72929c797c1cda"},{"bytes":2845,"name":"manifest.json","sha256":"c29e62d6af253745f55ee29bc0abafb2a2cab07bbff0d457013456ec27b92b8e"},{"bytes":89,"name":"manifest.sig","sha256":"7d5337c16431de4855d70c6b9389351dc10f5af7b11f4e4981e0271914fbebc2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"98c5a1ffab55d7707758d1a9f816835a6afbd47a5dbe8598919d6456fdf963e3"}],"publication_id":"OT-2026-000089449"} Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089449
OpenTechnical

OT-2026-000089449

Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
444e41e176ad47b3208053f2250d5b9e9258cc23dfba03bf7a72929c797c1cda

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089449, “Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089449.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089449" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089449" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089449 Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089449 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089449 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089449 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089449", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1213 }, "figures": [], "files": [ { "bytes": 19183, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "20ef48cdb73897e3d6b8430568e3827f6fdfc186a33a32e6aee57100f1290180" }, { "bytes": 8655, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "520bf7f36990601af59f2c1376ede953daf1861ac1158d9f79e082bd0e2eb432" }, { "bytes": 8322, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "444e41e176ad47b3208053f2250d5b9e9258cc23dfba03bf7a72929c797c1cda" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089449/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089449", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-70eb-bd66-310559de9587" } n5my9Ok/THOgjlUAgYmhO8meF5Ivj3RQ0dr7nWmB4lR9qO27y7THC4WSI4Ni0MMnYtFudxCXgfL3AJ2d7AR6Ag== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: n5my9Ok/THOgjlUAgYmhO8meF5Ivj3RQ0dr7nWmB4lR9qO27y7THC4WSI4Ni0MMnYtFudxCXgfL3AJ2d7AR6Ag== {"files":[{"bytes":18567,"name":"index.html","sha256":"ffdc6c44f667f817820158465aba8259bf2632b7b9da0f20a981958db38b6eca"},{"bytes":8110,"name":"publication.md","sha256":"8036cf73d0666ae88befadf42b712b418cfcc5cef9cef843d904d80a1cfdbdee"},{"bytes":7783,"name":"publication.txt","sha256":"0234ab4dac50b8584095e9d002ee078bdeeb24da0fd1744c47e388f29db7694f"},{"bytes":2833,"name":"manifest.json","sha256":"3baceb2e185f1d5e7bf3cb300e0bd4cb04d840a74caddda89ad8a22204662717"},{"bytes":89,"name":"manifest.sig","sha256":"1cb45aca1220b648659ae09d05723615cfa8ffac62b0f82963f6b6758b168af8"},{"bytes":227,"name":"manifest.sig.txt","sha256":"56cf2e710267ad441c00c9ab76bb606643ffa28638c661064455992797d185ec"}],"publication_id":"OT-2026-000089450"} Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089450
OpenTechnical

OT-2026-000089450

Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
0234ab4dac50b8584095e9d002ee078bdeeb24da0fd1744c47e388f29db7694f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089450, “Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089450.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089450" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089450" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089450 Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089450 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089450 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089450 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089450", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1127 }, "figures": [], "files": [ { "bytes": 18567, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ffdc6c44f667f817820158465aba8259bf2632b7b9da0f20a981958db38b6eca" }, { "bytes": 8110, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8036cf73d0666ae88befadf42b712b418cfcc5cef9cef843d904d80a1cfdbdee" }, { "bytes": 7783, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0234ab4dac50b8584095e9d002ee078bdeeb24da0fd1744c47e388f29db7694f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089450/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089450", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7240-bd7d-42a3a3ce55ca" } HuCwiqecIYNdFjCDTELPKDfpYfnXCXju5tlkEofXqsrYfpWlIJUQ8tlsVo/5k6LoWGG3pUPP21AKIP7wIkLyCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: HuCwiqecIYNdFjCDTELPKDfpYfnXCXju5tlkEofXqsrYfpWlIJUQ8tlsVo/5k6LoWGG3pUPP21AKIP7wIkLyCA== {"files":[{"bytes":19382,"name":"index.html","sha256":"9514fbcbdda1f3734ef404c73cb93f7c90b987f26209e97038029e9cec71d41a"},{"bytes":8811,"name":"publication.md","sha256":"a3553fc9a7363769152945a3a44f8d40b1c70e6c078bd605a2aa426471147cbe"},{"bytes":8478,"name":"publication.txt","sha256":"f9a6e8030c959c21199ae28a69a963b9719cd11e0c3856bccafec169e418014c"},{"bytes":2845,"name":"manifest.json","sha256":"94cb3744c00174d8069f2299595434ef66bd1c65b5d193bc277c0ae70d11df1a"},{"bytes":89,"name":"manifest.sig","sha256":"576444fc21a4f7c178adcae3d5e73a38c6aa9d542137d4766ed407ac0e4956a9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0a7e21ff411e31b8fb5bd803f37f1c96e7270e3eb3922107bcf36d8b005e2722"}],"publication_id":"OT-2026-000089451"} Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089451
OpenTechnical

OT-2026-000089451

Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f9a6e8030c959c21199ae28a69a963b9719cd11e0c3856bccafec169e418014c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089451, “Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089451.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089451" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089451" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089451 Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089451 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089451 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089451 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089451", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1233 }, "figures": [], "files": [ { "bytes": 19382, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9514fbcbdda1f3734ef404c73cb93f7c90b987f26209e97038029e9cec71d41a" }, { "bytes": 8811, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a3553fc9a7363769152945a3a44f8d40b1c70e6c078bd605a2aa426471147cbe" }, { "bytes": 8478, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f9a6e8030c959c21199ae28a69a963b9719cd11e0c3856bccafec169e418014c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089451/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089451", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-78a2-bbec-0147e7faa3b2" } yTa3gewGG/bT+V85Ka5Q2CZOrxDXoh4PHXQkC5tf8cDBg5/ndv8DuXBhoGCpkZSsSM+gixCw7VY0k/sN6UsfDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: yTa3gewGG/bT+V85Ka5Q2CZOrxDXoh4PHXQkC5tf8cDBg5/ndv8DuXBhoGCpkZSsSM+gixCw7VY0k/sN6UsfDw== {"files":[{"bytes":19129,"name":"index.html","sha256":"b25edcfc553539c924b26cc12f2127f78483beaf2c4c88e75ff23ce92ae013c1"},{"bytes":8601,"name":"publication.md","sha256":"34cf68139f778af26f3c9c2997ad36285a443b29b69f28af99979e9f59d40b7e"},{"bytes":8268,"name":"publication.txt","sha256":"1b21030b625e4e5a2fe897e13aa204b703e48ee5bf61e5598450e55e340ae2a2"},{"bytes":2845,"name":"manifest.json","sha256":"25d976f75b84c9c4fcf5baedef2d0912db9dc95fd2c48ea7d31a48b58677fab0"},{"bytes":89,"name":"manifest.sig","sha256":"b77d7638dd3bb056d1104b1a90fbd23985d6d0b54ee522cb464d12963e43839d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"099d6d25f3b860211f1879724d6dc24d7bf94551c7498b3bba38415ad81d28a6"}],"publication_id":"OT-2026-000089452"} Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089452
OpenTechnical

OT-2026-000089452

Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
1b21030b625e4e5a2fe897e13aa204b703e48ee5bf61e5598450e55e340ae2a2

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089452, “Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089452.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089452" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089452" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089452 Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089452 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089452 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089452 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089452", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1198 }, "figures": [], "files": [ { "bytes": 19129, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b25edcfc553539c924b26cc12f2127f78483beaf2c4c88e75ff23ce92ae013c1" }, { "bytes": 8601, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "34cf68139f778af26f3c9c2997ad36285a443b29b69f28af99979e9f59d40b7e" }, { "bytes": 8268, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1b21030b625e4e5a2fe897e13aa204b703e48ee5bf61e5598450e55e340ae2a2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089452/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089452", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7640-b2ef-62fbd7dd9e58" } qxRa7ePmRsVYHIWW/TJiqunImRZPiHxzPnQpesWh5wwHjDpvH7tyANDMES8O6V54FqtEn3po56GPOxoCOeSQCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: qxRa7ePmRsVYHIWW/TJiqunImRZPiHxzPnQpesWh5wwHjDpvH7tyANDMES8O6V54FqtEn3po56GPOxoCOeSQCA== {"files":[{"bytes":18321,"name":"index.html","sha256":"823dcac6edd7fba7489663d97e60b5f44bcf73143941fbb951c9d3c0e42e6bc7"},{"bytes":7912,"name":"publication.md","sha256":"c7002966576dd74402989a64e3eeba20d1a5d200ba25689f77a78a0494dfcec1"},{"bytes":7583,"name":"publication.txt","sha256":"1ee44ef063b590fe44aefc27396706b125acf0ca1a323bb43a88bf9a9d24bb5e"},{"bytes":2846,"name":"manifest.json","sha256":"203b11544108b028dbd4741a876b286370612cf1bc6d6f0e0fab6d15e6b29512"},{"bytes":89,"name":"manifest.sig","sha256":"963317eaf21bcd97153bca3f3ab649ff157d1b3d62dd6caebde60d17f4c67f02"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f6eaabc9b62f497c10053f98eeb09eb8eae833f79af6123d9afdb779ffe66e8a"}],"publication_id":"OT-2026-000089453"} Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089453
OpenTechnical

OT-2026-000089453

Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
1ee44ef063b590fe44aefc27396706b125acf0ca1a323bb43a88bf9a9d24bb5e

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089453, “Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089453.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089453" title: "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089453" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089453 Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089453 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089453 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089453 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089453", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1090 }, "figures": [], "files": [ { "bytes": 18321, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "823dcac6edd7fba7489663d97e60b5f44bcf73143941fbb951c9d3c0e42e6bc7" }, { "bytes": 7912, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c7002966576dd74402989a64e3eeba20d1a5d200ba25689f77a78a0494dfcec1" }, { "bytes": 7583, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1ee44ef063b590fe44aefc27396706b125acf0ca1a323bb43a88bf9a9d24bb5e" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089453/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089453", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7d42-99b6-666eceb50d1a" } DOqSTypBJrOC9x58TI1g+kmqqIM+JtqqKnuRjTQbVrpEq2xsg82tMXoYb80S7vmP+88r8klZMeXyMAe8PmTrBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: DOqSTypBJrOC9x58TI1g+kmqqIM+JtqqKnuRjTQbVrpEq2xsg82tMXoYb80S7vmP+88r8klZMeXyMAe8PmTrBw== {"files":[{"bytes":19136,"name":"index.html","sha256":"2af9d7624cee306c0afc48632d0cbced31396221f183193771775bec7a74b913"},{"bytes":8613,"name":"publication.md","sha256":"442fe0e3077285422c4304e659e61f9c531b6b058b17bfd2473de2e26c186a29"},{"bytes":8278,"name":"publication.txt","sha256":"f96b5fba8db0e56ffeba8718c1de4bf83f6a566e20f0388679223cf8d171cd4d"},{"bytes":2858,"name":"manifest.json","sha256":"d883b6f887b40b0dcb5b5283b5561b7bcb6eed425afd16f714d2c8fa1b2d64a4"},{"bytes":89,"name":"manifest.sig","sha256":"4bdc263302f932ec29218bea483161830ae2cf0491aadb9657e3eae9d645e8e1"},{"bytes":227,"name":"manifest.sig.txt","sha256":"843c49fbe5cd90d158f6c4d8f386dff81851f3af3d492eba442442fec20e09c8"}],"publication_id":"OT-2026-000089454"} Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089454
OpenTechnical

OT-2026-000089454

Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f96b5fba8db0e56ffeba8718c1de4bf83f6a566e20f0388679223cf8d171cd4d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089454, “Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089454.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089454" title: "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089454" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089454 Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089454 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089454 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089454 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089454", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1196 }, "figures": [], "files": [ { "bytes": 19136, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2af9d7624cee306c0afc48632d0cbced31396221f183193771775bec7a74b913" }, { "bytes": 8613, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "442fe0e3077285422c4304e659e61f9c531b6b058b17bfd2473de2e26c186a29" }, { "bytes": 8278, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f96b5fba8db0e56ffeba8718c1de4bf83f6a566e20f0388679223cf8d171cd4d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089454/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089454", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7cde-99e7-a473e2ba21a1" } /CVAnQ+X4mJ2qicwL2japJavdczmaof5GZ6fgyWVANjmEA2MHMDaBp0Ec24rMaigwuQ4o7fz+M9/vuVkP+sMAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: /CVAnQ+X4mJ2qicwL2japJavdczmaof5GZ6fgyWVANjmEA2MHMDaBp0Ec24rMaigwuQ4o7fz+M9/vuVkP+sMAw== {"files":[{"bytes":18883,"name":"index.html","sha256":"a0e32b99cbf59a296d94db73455d2826880b05aed619cd9d5ea6c29b57715edb"},{"bytes":8403,"name":"publication.md","sha256":"d8917f8d4104c6dd7d48efc345bc6823022e1dacc657921f4a1a2b9f1c9cfe70"},{"bytes":8068,"name":"publication.txt","sha256":"c7d48997f15bcfa14cf60fae90b8ad64f7e32373f5eb6b53b9dadc403929209c"},{"bytes":2858,"name":"manifest.json","sha256":"78207db78e33a53f221445cb940cbdcb3c5b04dfb11bd634bbeb09db58a50cd5"},{"bytes":89,"name":"manifest.sig","sha256":"b144778cf802ded9941bf83b4e946b56caa46cd0cd42da9ce1ba7ff48ec7a449"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7351b9d90ce327369eb0bbc12506a551e8c5868f55aed3bf1c14db9b946a725c"}],"publication_id":"OT-2026-000089455"} Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089455
OpenTechnical

OT-2026-000089455

Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c7d48997f15bcfa14cf60fae90b8ad64f7e32373f5eb6b53b9dadc403929209c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089455, “Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089455.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089455" title: "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089455" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089455 Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089455 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089455 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089455 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089455", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1161 }, "figures": [], "files": [ { "bytes": 18883, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a0e32b99cbf59a296d94db73455d2826880b05aed619cd9d5ea6c29b57715edb" }, { "bytes": 8403, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d8917f8d4104c6dd7d48efc345bc6823022e1dacc657921f4a1a2b9f1c9cfe70" }, { "bytes": 8068, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c7d48997f15bcfa14cf60fae90b8ad64f7e32373f5eb6b53b9dadc403929209c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089455/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089455", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7c77-ad54-cf160e68599f" } KDm0ACR1v/YrdMDOfiOWZP2peBhxGbgzVbODorDKpNW87T+vJ6+3GOnA2M7aR6xxwWFhgiOMPsLLRGrp64rTAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: KDm0ACR1v/YrdMDOfiOWZP2peBhxGbgzVbODorDKpNW87T+vJ6+3GOnA2M7aR6xxwWFhgiOMPsLLRGrp64rTAQ== {"files":[{"bytes":18321,"name":"index.html","sha256":"aabf6299ea251d6ab03118b8b4fe787f2b9d1f0c368d1d092556ecb1453dba2c"},{"bytes":7912,"name":"publication.md","sha256":"1c2e2e1f77ea1f3a8f83d63abdc644a6bbd3e1385f051bae042732d250a48713"},{"bytes":7583,"name":"publication.txt","sha256":"65ff77a991eb7ddea2063c3ad6cbddb7d4d7b62927ada02494cd96b402732b7d"},{"bytes":2846,"name":"manifest.json","sha256":"5e0312a2509ef5bee601864da2c2829ac353b3d31f3bd14b5aab16277320bd76"},{"bytes":89,"name":"manifest.sig","sha256":"5492f48b861b74e488fd0864728404a13f0cd7952e0583038bb43b3c6eb23d55"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f461ebbbf535af6844b5454b292ca42283787ef2f3f09e533a484b0d13984325"}],"publication_id":"OT-2026-000089456"} Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089456
OpenTechnical

OT-2026-000089456

Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
65ff77a991eb7ddea2063c3ad6cbddb7d4d7b62927ada02494cd96b402732b7d

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089456, “Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089456.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089456" title: "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089456" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089456 Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089456 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089456 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089456 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089456", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1090 }, "figures": [], "files": [ { "bytes": 18321, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "aabf6299ea251d6ab03118b8b4fe787f2b9d1f0c368d1d092556ecb1453dba2c" }, { "bytes": 7912, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1c2e2e1f77ea1f3a8f83d63abdc644a6bbd3e1385f051bae042732d250a48713" }, { "bytes": 7583, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "65ff77a991eb7ddea2063c3ad6cbddb7d4d7b62927ada02494cd96b402732b7d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089456/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089456", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7d08-bdaa-f38ea8928b28" } pp+oEhXA6B4704e3Fh+N9jJgLq++wc7L9uR/JJYuAjYkw2GkbzXpNAgnlldy+lx6SBj87GqMVnBX/Z8G1DuuCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: pp+oEhXA6B4704e3Fh+N9jJgLq++wc7L9uR/JJYuAjYkw2GkbzXpNAgnlldy+lx6SBj87GqMVnBX/Z8G1DuuCA== {"files":[{"bytes":19136,"name":"index.html","sha256":"0b84f757d119c8056ee45c20fe32a4249363f9870d6b1e8a3bba112f02fc5cdc"},{"bytes":8613,"name":"publication.md","sha256":"a749e87801681a88f8b3fb4a4d19b0e02c293438782420da7519faafe323e2b1"},{"bytes":8278,"name":"publication.txt","sha256":"5726d69689c8a1c78e9f0bbd7d21878030428a77e1ed5df6fecc9869cf1fd2c5"},{"bytes":2858,"name":"manifest.json","sha256":"7c123fb293330159faf87deccc5989d8d14b6ef1011743856c1c28be1569f39b"},{"bytes":89,"name":"manifest.sig","sha256":"acf05bff137854941246a7bf201534d3c2813499161cda9b581ba5c472142403"},{"bytes":227,"name":"manifest.sig.txt","sha256":"17ed0ac15184db037af5bc669eeff8e0cad294875dc272f3e2d33bee6d0fac81"}],"publication_id":"OT-2026-000089457"} Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089457
OpenTechnical

OT-2026-000089457

Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
5726d69689c8a1c78e9f0bbd7d21878030428a77e1ed5df6fecc9869cf1fd2c5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089457, “Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089457.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089457" title: "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089457" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089457 Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089457 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089457 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089457 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089457", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1196 }, "figures": [], "files": [ { "bytes": 19136, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "0b84f757d119c8056ee45c20fe32a4249363f9870d6b1e8a3bba112f02fc5cdc" }, { "bytes": 8613, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a749e87801681a88f8b3fb4a4d19b0e02c293438782420da7519faafe323e2b1" }, { "bytes": 8278, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5726d69689c8a1c78e9f0bbd7d21878030428a77e1ed5df6fecc9869cf1fd2c5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089457/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089457", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7563-83d8-344ff21e2644" } j4WhIdDRWK3u1gl+NEtO9NiENBr6KHTO/cyj3l0vmzjHrVnVl8n7uwv1yVFDsH7+KSmye1pJ2wWhZNg+gltkCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: j4WhIdDRWK3u1gl+NEtO9NiENBr6KHTO/cyj3l0vmzjHrVnVl8n7uwv1yVFDsH7+KSmye1pJ2wWhZNg+gltkCw== {"files":[{"bytes":18883,"name":"index.html","sha256":"94468cd07c832212b92cce3343e00a9c1244a0ad020f884a446029a8fe952dec"},{"bytes":8403,"name":"publication.md","sha256":"732db33a96570883d496081a2f880f40957710481147142e1fd20ca4bf74bd11"},{"bytes":8068,"name":"publication.txt","sha256":"cab5b08cfce413f716292037e04668a8c9baa0fcf27db097f26c45f1e6ee478d"},{"bytes":2858,"name":"manifest.json","sha256":"aa7520f2e49c87e5878e40df4467228922fabdbf8bbd11126e3089cc47dffb8e"},{"bytes":89,"name":"manifest.sig","sha256":"5f4ad73569c9139f385be44c758e8580420145b6ce34a81e77c76acadf5e44a2"},{"bytes":227,"name":"manifest.sig.txt","sha256":"2938741567e43f9863ad7f76d4197bfc0dd96f299152d9665a0b1c999bd492ec"}],"publication_id":"OT-2026-000089458"} Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089458
OpenTechnical

OT-2026-000089458

Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
cab5b08cfce413f716292037e04668a8c9baa0fcf27db097f26c45f1e6ee478d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089458, “Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089458.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089458" title: "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089458" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089458 Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089458 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has three stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: three (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089458 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089458 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one ejector, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089458", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1161 }, "figures": [], "files": [ { "bytes": 18883, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "94468cd07c832212b92cce3343e00a9c1244a0ad020f884a446029a8fe952dec" }, { "bytes": 8403, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "732db33a96570883d496081a2f880f40957710481147142e1fd20ca4bf74bd11" }, { "bytes": 8068, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "cab5b08cfce413f716292037e04668a8c9baa0fcf27db097f26c45f1e6ee478d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089458/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089458", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, three stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-75e5-b0d9-64280516fa60" } uP67TWUbvPZjebVhWjplZRYoJyxEjG0TqE3v299DmUtCcMYFvGDXX11i484S8J2yukFUIHIqfT8YXUAo7IAsBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: uP67TWUbvPZjebVhWjplZRYoJyxEjG0TqE3v299DmUtCcMYFvGDXX11i484S8J2yukFUIHIqfT8YXUAo7IAsBQ== {"files":[{"bytes":18318,"name":"index.html","sha256":"dbda8203f8a0151201dcdff989c2e6a40953f23e12611b15995de6b293cb0c85"},{"bytes":7962,"name":"publication.md","sha256":"057f69c49b672f39b666a16c90aa86aafc8702d53e8e537d714e35ac72a83461"},{"bytes":7605,"name":"publication.txt","sha256":"f775bc0a276ed4f2c54632c4bcd869ee692c1acc8cf733fa1205e88abfc88f19"},{"bytes":2906,"name":"manifest.json","sha256":"5ffcb26ae96cd157ca8a4b8245db3a7c02c61b77686f946e86a91be9416a5bb3"},{"bytes":89,"name":"manifest.sig","sha256":"1ce317eb1fd88c6fa2d10ddf67cc737b9a017728dec5b46c4143c4fca0f01375"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8169f42729768673fc33ff2950ccf16f3de218af1d0fbe3953372089dc09a962"}],"publication_id":"OT-2026-000089459"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089459
OpenTechnical

OT-2026-000089459

Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
f775bc0a276ed4f2c54632c4bcd869ee692c1acc8cf733fa1205e88abfc88f19

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089459, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089459.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089459" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089459" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089459 Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089459 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089459 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089459 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089459", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1085 }, "figures": [], "files": [ { "bytes": 18318, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "dbda8203f8a0151201dcdff989c2e6a40953f23e12611b15995de6b293cb0c85" }, { "bytes": 7962, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "057f69c49b672f39b666a16c90aa86aafc8702d53e8e537d714e35ac72a83461" }, { "bytes": 7605, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f775bc0a276ed4f2c54632c4bcd869ee692c1acc8cf733fa1205e88abfc88f19" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089459/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089459", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7bd5-b2cc-ca7808ce653d" } MYGFikyi6EZoJgWdAI5cBnUrl+V4HCutiTN/+wAQdoNnMLDYT0aN41V3eQe+sMw4FAaXMcLs2Mll2ZILaxIEDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: MYGFikyi6EZoJgWdAI5cBnUrl+V4HCutiTN/+wAQdoNnMLDYT0aN41V3eQe+sMw4FAaXMcLs2Mll2ZILaxIEDw== {"files":[{"bytes":19124,"name":"index.html","sha256":"e120ff1e327862a39e619f4d231b94c437c0e5d6a97de78e08f837499b199313"},{"bytes":8650,"name":"publication.md","sha256":"cbb6ad5d346eaa5bad236f0b97e9ce5a45ed5b7ad24259e2151f3c6f3ffeb7c9"},{"bytes":8294,"name":"publication.txt","sha256":"7ca847169cbbe8f206a7902330b0fe88c35ac59ded9877f7085d30e1e1b1aa09"},{"bytes":2911,"name":"manifest.json","sha256":"b81dbef8104f35f2cf1c20c2bb78722aded19157a6cc87f99b786dee6dfead0a"},{"bytes":89,"name":"manifest.sig","sha256":"8e8089d7b02ada6cd12c0f5bf433f04350a5e9f49eefd5625f2e88fd1f4ffcf0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7c77aa92538488705bbe9563630c0acbcf6b18d352eb759d27d92b53c6ed83b5"}],"publication_id":"OT-2026-000089460"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089460
OpenTechnical

OT-2026-000089460

Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7ca847169cbbe8f206a7902330b0fe88c35ac59ded9877f7085d30e1e1b1aa09

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089460, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089460.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089460" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089460" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089460 Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089460 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089460 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089460 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089460", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1191 }, "figures": [], "files": [ { "bytes": 19124, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "e120ff1e327862a39e619f4d231b94c437c0e5d6a97de78e08f837499b199313" }, { "bytes": 8650, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "cbb6ad5d346eaa5bad236f0b97e9ce5a45ed5b7ad24259e2151f3c6f3ffeb7c9" }, { "bytes": 8294, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7ca847169cbbe8f206a7902330b0fe88c35ac59ded9877f7085d30e1e1b1aa09" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089460/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089460", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7bf1-b8ae-3c4bc13b1d1e" } cIyN9ZsrN8UFIzcYp/4q6EX6k0vHW/49P+b7KLt+AvaXaMp/n3PxE1DYPKcoeXzPVGCDA53akwVnvlixzRnaAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: cIyN9ZsrN8UFIzcYp/4q6EX6k0vHW/49P+b7KLt+AvaXaMp/n3PxE1DYPKcoeXzPVGCDA53akwVnvlixzRnaAw== {"files":[{"bytes":18871,"name":"index.html","sha256":"2c483422e7d08425cf99fbb04c6d9891972a7d1a84db346cb049e025ab79e765"},{"bytes":8440,"name":"publication.md","sha256":"8256151489aa0a0d0987512589738c8d3df4b6724b406af38bf516a28e7f2845"},{"bytes":8084,"name":"publication.txt","sha256":"47fe50e3ca835e4bf589d5b8dbaebeb264c59fd400d949c103c502b543c6e36b"},{"bytes":2911,"name":"manifest.json","sha256":"40a2b3c6752e1ded4c7a753f8d80af78a1b0787feb8534cdbe7c5c06d0ca5569"},{"bytes":89,"name":"manifest.sig","sha256":"bc5e81a6740f41dc2c918f524463185b485cd73106e0b4c2accb2f9bb43753fd"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1c2c5758da0a5675d441dac7b699faead4f8ad66176bdb9fe462f50c1d18c16e"}],"publication_id":"OT-2026-000089461"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089461
OpenTechnical

OT-2026-000089461

Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
47fe50e3ca835e4bf589d5b8dbaebeb264c59fd400d949c103c502b543c6e36b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089461, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089461.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089461" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089461" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089461 Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089461 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089461 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089461 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089461", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1156 }, "figures": [], "files": [ { "bytes": 18871, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2c483422e7d08425cf99fbb04c6d9891972a7d1a84db346cb049e025ab79e765" }, { "bytes": 8440, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8256151489aa0a0d0987512589738c8d3df4b6724b406af38bf516a28e7f2845" }, { "bytes": 8084, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "47fe50e3ca835e4bf589d5b8dbaebeb264c59fd400d949c103c502b543c6e36b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089461/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089461", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7c09-8893-ec19eac9684b" } rZ5B3HqGdP5fLs749dgVBEog29FWeL0qkSHTIZZ+KRKVUJTHB9nSZmA4xN3mMubYiZgeyJjU1DfBu4i/DoB8AQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: rZ5B3HqGdP5fLs749dgVBEog29FWeL0qkSHTIZZ+KRKVUJTHB9nSZmA4xN3mMubYiZgeyJjU1DfBu4i/DoB8AQ== {"files":[{"bytes":18319,"name":"index.html","sha256":"26854bff694c1ccc428eee35054ca4b36ba7159d02419bf1b0319efc579fb00b"},{"bytes":7963,"name":"publication.md","sha256":"09c0881cfa77b532477a39f349382984eb1451c321e38d3c2613949aa590f312"},{"bytes":7606,"name":"publication.txt","sha256":"befa64882b3fd0f15c9e20214238eb722ece6514d73761c8c8ec90e6c0a73e93"},{"bytes":2906,"name":"manifest.json","sha256":"4a5896b890c476495ccc3efc51c4a4a5b57335825e4bf04bbca87a208558643a"},{"bytes":89,"name":"manifest.sig","sha256":"d08137688b95fbdab0e53081b11a03da3e3db66c34522c7c422807fd33f89340"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a9538e562cdc9e9de7a986ac100002fc7e864b5cc8b8785cad36b2ec1dc9c8df"}],"publication_id":"OT-2026-000089462"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089462
OpenTechnical

OT-2026-000089462

Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
befa64882b3fd0f15c9e20214238eb722ece6514d73761c8c8ec90e6c0a73e93

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089462, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089462.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089462" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089462" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089462 Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089462 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089462 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089462 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089462", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1085 }, "figures": [], "files": [ { "bytes": 18319, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "26854bff694c1ccc428eee35054ca4b36ba7159d02419bf1b0319efc579fb00b" }, { "bytes": 7963, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "09c0881cfa77b532477a39f349382984eb1451c321e38d3c2613949aa590f312" }, { "bytes": 7606, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "befa64882b3fd0f15c9e20214238eb722ece6514d73761c8c8ec90e6c0a73e93" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089462/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089462", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7e27-a4ea-42ec332374be" } LssqOf5dZR41slnS8tsX6/w6NbPD/VK+rE8pmlX4OgAQ5ZzAx12FMXuDOAnaVz7LW1ahMFXgVteZp3GwMtaaAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: LssqOf5dZR41slnS8tsX6/w6NbPD/VK+rE8pmlX4OgAQ5ZzAx12FMXuDOAnaVz7LW1ahMFXgVteZp3GwMtaaAg== {"files":[{"bytes":19125,"name":"index.html","sha256":"a9e35a0c3b4b0c5d8d7057fe1103664aace625006cbc949b3543d9cc52c5aec8"},{"bytes":8651,"name":"publication.md","sha256":"e362cbbf2a06c8efc473b5cb7e65e20d995337218dc6a3a6d5e67ad74b356713"},{"bytes":8295,"name":"publication.txt","sha256":"d7d7c7b3857f917652a77f393b4c69b83923f66c11722609f99b2ccc379eb2bc"},{"bytes":2911,"name":"manifest.json","sha256":"072792345ec8bad1d70c3445bb3259921f2883dede87d72252c3733a02c1b558"},{"bytes":89,"name":"manifest.sig","sha256":"803328ba035859bc39a100f8a8258043a45dce2128a928d24c3c17e534125d7e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0858997d64946ff0be2da289aee579baec49ad82b525596ad6b993a6599c2726"}],"publication_id":"OT-2026-000089463"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089463
OpenTechnical

OT-2026-000089463

Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
d7d7c7b3857f917652a77f393b4c69b83923f66c11722609f99b2ccc379eb2bc

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089463, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089463.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089463" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089463" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089463 Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089463 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089463 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089463 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089463", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1191 }, "figures": [], "files": [ { "bytes": 19125, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a9e35a0c3b4b0c5d8d7057fe1103664aace625006cbc949b3543d9cc52c5aec8" }, { "bytes": 8651, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e362cbbf2a06c8efc473b5cb7e65e20d995337218dc6a3a6d5e67ad74b356713" }, { "bytes": 8295, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d7d7c7b3857f917652a77f393b4c69b83923f66c11722609f99b2ccc379eb2bc" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089463/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089463", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7018-9e0a-8ba7f7906142" } POvW17IHgVn4N+85L+0h69dvIVVCkdEFI5ACttRNoYmAKa/XsFkCfN2IrZ0zLeUdbRwavB3XowATBys5G47hDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: POvW17IHgVn4N+85L+0h69dvIVVCkdEFI5ACttRNoYmAKa/XsFkCfN2IrZ0zLeUdbRwavB3XowATBys5G47hDg== {"files":[{"bytes":18872,"name":"index.html","sha256":"f8f329ea9eb6e86c4e8b6ebee692decbe731740894fe343588badbcbf544c25e"},{"bytes":8441,"name":"publication.md","sha256":"49cd7b5bb94287164a290f2e3f12258ea4dce3d9dd2e34b9ba41ca8b0509fac3"},{"bytes":8085,"name":"publication.txt","sha256":"b37ed9b30b476ae0dce122804ea30d24e07afe567264232ccc5bb5053a554600"},{"bytes":2911,"name":"manifest.json","sha256":"95b6bbf4abd132b34c80f023e967d4abbe88fdd9a946d555171fca60ee6a9163"},{"bytes":89,"name":"manifest.sig","sha256":"a0c497d4fbd259962db624c03272ab9ca9c66e1405933fd41e17d9756f6fcd3b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"dc7c7a1e432ac18b22378afa4bfce759b421020d44816cb9c4d15636acef04ac"}],"publication_id":"OT-2026-000089464"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089464
OpenTechnical

OT-2026-000089464

Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
b37ed9b30b476ae0dce122804ea30d24e07afe567264232ccc5bb5053a554600

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089464, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089464.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089464" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089464" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089464 Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089464 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089464 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089464 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089464", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1156 }, "figures": [], "files": [ { "bytes": 18872, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f8f329ea9eb6e86c4e8b6ebee692decbe731740894fe343588badbcbf544c25e" }, { "bytes": 8441, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "49cd7b5bb94287164a290f2e3f12258ea4dce3d9dd2e34b9ba41ca8b0509fac3" }, { "bytes": 8085, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b37ed9b30b476ae0dce122804ea30d24e07afe567264232ccc5bb5053a554600" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089464/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089464", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7221-b2c6-e3b8a51985e4" } dr33Ukf2tziCyOScG35Rjf5LscswP/xBeAQSxUBJcGpxiuzGV9FI/cnW1Sg3Ogj99jKzJZZIEpz+Ih3lywjeCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: dr33Ukf2tziCyOScG35Rjf5LscswP/xBeAQSxUBJcGpxiuzGV9FI/cnW1Sg3Ogj99jKzJZZIEpz+Ih3lywjeCQ== {"files":[{"bytes":18323,"name":"index.html","sha256":"1d7a80d4370d5a6e0c0af317488312697602c8444cca1c83f88ea9126dd63627"},{"bytes":7967,"name":"publication.md","sha256":"0241edc650da9b7b4c15d5b7484a6814e00d58bd480216b655aeb30b3a5a474a"},{"bytes":7610,"name":"publication.txt","sha256":"9295f4457d23cadc11ab765445a9436e1a1597b1d3c77032fc575e7909ee4ba1"},{"bytes":2906,"name":"manifest.json","sha256":"f53875ac1a742a7e923e689859ed2c9e30a5a9134035dfbe8d45418a8fb04e8b"},{"bytes":89,"name":"manifest.sig","sha256":"47815cb84d8026b55bb07b01d1c39212e54de115ff1fe15ff9fa458905305131"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e25fed11b5aba7b60618e35167df572111fd5538fed1392461dde92e65c6c438"}],"publication_id":"OT-2026-000089465"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089465
OpenTechnical

OT-2026-000089465

Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
9295f4457d23cadc11ab765445a9436e1a1597b1d3c77032fc575e7909ee4ba1

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089465, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089465.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089465" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089465" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089465 Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089465 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089465 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089465 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089465", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1085 }, "figures": [], "files": [ { "bytes": 18323, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1d7a80d4370d5a6e0c0af317488312697602c8444cca1c83f88ea9126dd63627" }, { "bytes": 7967, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0241edc650da9b7b4c15d5b7484a6814e00d58bd480216b655aeb30b3a5a474a" }, { "bytes": 7610, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9295f4457d23cadc11ab765445a9436e1a1597b1d3c77032fc575e7909ee4ba1" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089465/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089465", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7486-9b7a-01b8954040ab" } GFSqmdLBjrAtzFTaNiz7WTPTfyZpNGrb749XrMOCVPUeaAK1TfNkCffx5p3lH+Gx/RBpvjiDLXEj+GMCNOsgAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: GFSqmdLBjrAtzFTaNiz7WTPTfyZpNGrb749XrMOCVPUeaAK1TfNkCffx5p3lH+Gx/RBpvjiDLXEj+GMCNOsgAg== {"files":[{"bytes":19129,"name":"index.html","sha256":"1236ca2a768bd820edf30889fdd587204a9c75559549ec0871b49bc4e9ad0eed"},{"bytes":8655,"name":"publication.md","sha256":"6a44adf3cde115a2c35495a952164963f3a7890a9dca1d3fbc13d956608f7039"},{"bytes":8299,"name":"publication.txt","sha256":"0a128e60407056c48ca24800b4e0668194ce95777338c40e42f452a442519d3c"},{"bytes":2911,"name":"manifest.json","sha256":"b06e1347f7e5abf3eede8fdafd6f61f39058376ce6cabdf3d2309f5f3efa25a0"},{"bytes":89,"name":"manifest.sig","sha256":"eaa7f18c3fa9e81783ef98fdc18f86f9c8df56cf24f2615ddced902b2b4ba863"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ead9632fb31c004c42501a921013ff39f5ebac643eae3d6fc6455fa700145af9"}],"publication_id":"OT-2026-000089466"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089466
OpenTechnical

OT-2026-000089466

Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
0a128e60407056c48ca24800b4e0668194ce95777338c40e42f452a442519d3c

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089466, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089466.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089466" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089466" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089466 Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089466 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089466 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089466 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089466", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1191 }, "figures": [], "files": [ { "bytes": 19129, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1236ca2a768bd820edf30889fdd587204a9c75559549ec0871b49bc4e9ad0eed" }, { "bytes": 8655, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "6a44adf3cde115a2c35495a952164963f3a7890a9dca1d3fbc13d956608f7039" }, { "bytes": 8299, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "0a128e60407056c48ca24800b4e0668194ce95777338c40e42f452a442519d3c" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089466/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089466", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7b63-b460-2ebe938f8ada" } 2Mx1KLKbFpXvhuIn0oqmtZzziF/sBWwN0BQPTd3mbPUu1ywDE0hrebdtrbxkP5E3AtS0NM7jTqxNtjAqr0p4CA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 2Mx1KLKbFpXvhuIn0oqmtZzziF/sBWwN0BQPTd3mbPUu1ywDE0hrebdtrbxkP5E3AtS0NM7jTqxNtjAqr0p4CA== {"files":[{"bytes":18876,"name":"index.html","sha256":"531bbc14791118476638928eb63350cb7a72bb9578050b4a86b7d67607468194"},{"bytes":8445,"name":"publication.md","sha256":"14d6f15c14907aee07bdf80d070a1cc718c001b81dcc06c81c68436d67b0fea0"},{"bytes":8089,"name":"publication.txt","sha256":"6026cbde4bd6385eec7b9ddc022baab86e99d0cb641f8493b897be760e97e98e"},{"bytes":2911,"name":"manifest.json","sha256":"79a3b29c09d74517beb0eb61bcc0a44f10d67d2c53575de6694b891a927fd65b"},{"bytes":89,"name":"manifest.sig","sha256":"6e9e100722d09a0525a7849543ed80d484889ef508ec806ab8c11c2dd5cec3ec"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4b105949fb7db84a8c691f8549de558d1df93e2c5b5b54b8d43053ea554c406f"}],"publication_id":"OT-2026-000089467"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089467
OpenTechnical

OT-2026-000089467

Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
6026cbde4bd6385eec7b9ddc022baab86e99d0cb641f8493b897be760e97e98e

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089467, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089467.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089467" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089467" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089467 Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089467 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089467 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089467 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089467", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1156 }, "figures": [], "files": [ { "bytes": 18876, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "531bbc14791118476638928eb63350cb7a72bb9578050b4a86b7d67607468194" }, { "bytes": 8445, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "14d6f15c14907aee07bdf80d070a1cc718c001b81dcc06c81c68436d67b0fea0" }, { "bytes": 8089, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "6026cbde4bd6385eec7b9ddc022baab86e99d0cb641f8493b897be760e97e98e" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089467/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089467", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-717c-8d2e-27227563b99f" } uFRWH4M6NNyCqZT8iaFv9QLc4cL+n8MeFTbR6/5lECTAQnNNxyxD0wPLDS1yAloLB4HMObIkGzMRQQqLgmpWDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: uFRWH4M6NNyCqZT8iaFv9QLc4cL+n8MeFTbR6/5lECTAQnNNxyxD0wPLDS1yAloLB4HMObIkGzMRQQqLgmpWDA== {"files":[{"bytes":18512,"name":"index.html","sha256":"bfdc8460519b71ab07597c88b62d8e3cc11cf50f34764aba8c411dde39f9dc26"},{"bytes":8124,"name":"publication.md","sha256":"854d7f16145a17e70f88a8b7c71fc84c117bec9a0cb49165b3f55f679686acc0"},{"bytes":7777,"name":"publication.txt","sha256":"6081cc49b81ab8b81cb9090d710a77bb065e2cd371879d05c184ee52aea10d56"},{"bytes":2885,"name":"manifest.json","sha256":"c3f675cf2bd6124eaf2566f81f70a82a4ce498b4158646644f3dc9fe7c357ba5"},{"bytes":89,"name":"manifest.sig","sha256":"3c04ab0a1da7dee898c3715fc79d89a657dcaa1b79d70cf1f3d92d4f221a8f3e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9e407b663da7eee96c116f963c21cfc7cac4d3ac9990d4cc6c610bfa77b99a2e"}],"publication_id":"OT-2026-000089468"} Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089468
OpenTechnical

OT-2026-000089468

Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
6081cc49b81ab8b81cb9090d710a77bb065e2cd371879d05c184ee52aea10d56

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089468, “Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089468.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089468" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089468" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089468 Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089468 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089468 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089468 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089468", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1125 }, "figures": [], "files": [ { "bytes": 18512, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bfdc8460519b71ab07597c88b62d8e3cc11cf50f34764aba8c411dde39f9dc26" }, { "bytes": 8124, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "854d7f16145a17e70f88a8b7c71fc84c117bec9a0cb49165b3f55f679686acc0" }, { "bytes": 7777, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "6081cc49b81ab8b81cb9090d710a77bb065e2cd371879d05c184ee52aea10d56" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089468/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089468", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7a2b-a266-f32e9f5f3e64" } /vbnXKzoexQaFDEM3IHlnaemWlQy1eg81vxCtch/VYo16b0+FUvB9W2W4dfr3hvrAFVPg36WCYnqoitPX52PAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: /vbnXKzoexQaFDEM3IHlnaemWlQy1eg81vxCtch/VYo16b0+FUvB9W2W4dfr3hvrAFVPg36WCYnqoitPX52PAg== {"files":[{"bytes":19318,"name":"index.html","sha256":"a435759e7b4335ebf1a85959089387e86a2b8adf029b03e7a271f433a1208613"},{"bytes":8812,"name":"publication.md","sha256":"e2559a350962591584000a3649b74c4f934096579f0211d6e82c51bc705e65f0"},{"bytes":8466,"name":"publication.txt","sha256":"82787dc42b0233a86878a4f6ac32e08d34d21a92597b55c7f98723d5ade06976"},{"bytes":2890,"name":"manifest.json","sha256":"62ddaf60ca1f9ceff5e0672630819729acbd7d05c0945efdacf6a1a06391ec08"},{"bytes":89,"name":"manifest.sig","sha256":"e5069288a0d9fc2bc21830c0cd5c465d063a693d8431270497b4e5e69b7860b7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"948f2e4878e251183b141db1fa7920b0d6fc9f3ce40f4826af8c4d7b6eeb4746"}],"publication_id":"OT-2026-000089469"} Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089469
OpenTechnical

OT-2026-000089469

Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
82787dc42b0233a86878a4f6ac32e08d34d21a92597b55c7f98723d5ade06976

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089469, “Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089469.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089469" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089469" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089469 Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089469 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089469 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089469 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089469", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1231 }, "figures": [], "files": [ { "bytes": 19318, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a435759e7b4335ebf1a85959089387e86a2b8adf029b03e7a271f433a1208613" }, { "bytes": 8812, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e2559a350962591584000a3649b74c4f934096579f0211d6e82c51bc705e65f0" }, { "bytes": 8466, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "82787dc42b0233a86878a4f6ac32e08d34d21a92597b55c7f98723d5ade06976" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089469/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089469", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7d31-a4be-d138bbebce44" } njN7bIRYdKmyeLpJKeRVYfB6A1SAXhscrCC8GpcxkC7+cJU3AFJ5xp3TNV16P+owVa0CB4FnOyvdj0+VlzqBDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: njN7bIRYdKmyeLpJKeRVYfB6A1SAXhscrCC8GpcxkC7+cJU3AFJ5xp3TNV16P+owVa0CB4FnOyvdj0+VlzqBDg== {"files":[{"bytes":19065,"name":"index.html","sha256":"27cf752375d1875baa3a2f7a6c576492cab58845f34f8a58fd32f728f37a2213"},{"bytes":8602,"name":"publication.md","sha256":"17919bf65f2cb779b7df8bca208438c4e54502fe39dea8780a60d598e4a101be"},{"bytes":8256,"name":"publication.txt","sha256":"53c3c8defd5bcaefc829329259f3d14196ae1ed79bac0a9d4d826c6eb05fd15b"},{"bytes":2890,"name":"manifest.json","sha256":"0d55ae6784c3363979eca887d01b36e48f395637a1d06feb7ea15b7ac5ab89ad"},{"bytes":89,"name":"manifest.sig","sha256":"58088b821faf09cc93ce3dc0520da4edebad599aa82b6cbcdec36b6004327d3c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"308a25a5b98adaab5aa0bfd596e6136048a99eb25858e02f7c974d6327dc59d2"}],"publication_id":"OT-2026-000089470"} Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089470
OpenTechnical

OT-2026-000089470

Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
53c3c8defd5bcaefc829329259f3d14196ae1ed79bac0a9d4d826c6eb05fd15b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089470, “Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089470.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089470" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089470" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089470 Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089470 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089470 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089470 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089470", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1196 }, "figures": [], "files": [ { "bytes": 19065, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "27cf752375d1875baa3a2f7a6c576492cab58845f34f8a58fd32f728f37a2213" }, { "bytes": 8602, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "17919bf65f2cb779b7df8bca208438c4e54502fe39dea8780a60d598e4a101be" }, { "bytes": 8256, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "53c3c8defd5bcaefc829329259f3d14196ae1ed79bac0a9d4d826c6eb05fd15b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089470/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089470", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-72e8-bda4-889c5bae64e6" } sOVCxP9j/0HYs+aa6QE7ZLssnKEgCcBeyEn1SfqDyKcClZw5bgAcdXTcTRyfrD3fzEU2ykpS5k8wbtyyDBIKDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: sOVCxP9j/0HYs+aa6QE7ZLssnKEgCcBeyEn1SfqDyKcClZw5bgAcdXTcTRyfrD3fzEU2ykpS5k8wbtyyDBIKDw== {"files":[{"bytes":18458,"name":"index.html","sha256":"807ad64062599d9f8e0ca14c7d310a93440f3e7272ffc7cb04c778ab8c4c9d38"},{"bytes":8070,"name":"publication.md","sha256":"a01610ead00df890de15445ef2b93fa81d9bff8d8ee01b8e18435fd38701c224"},{"bytes":7723,"name":"publication.txt","sha256":"2a92e04b714af3f3fb194ecb1d1bab01785971ba0f048ae83a2826ab69ae46db"},{"bytes":2885,"name":"manifest.json","sha256":"9ed4034bf6640ff95f867f7b99649f933e4826d6e213a921619ae0f173bab3cb"},{"bytes":89,"name":"manifest.sig","sha256":"645f075e72e0143a6b6ac1c4efcde39de58735e6e462f63defb450426f6c8326"},{"bytes":227,"name":"manifest.sig.txt","sha256":"5215fc5398d24d173aeb9ad2eee23b8d2b9d0adb525a47041e13f76612c2d36b"}],"publication_id":"OT-2026-000089471"} Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089471
OpenTechnical

OT-2026-000089471

Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
2a92e04b714af3f3fb194ecb1d1bab01785971ba0f048ae83a2826ab69ae46db

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089471, “Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089471.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089471" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089471" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089471 Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089471 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089471 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089471 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089471", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1110 }, "figures": [], "files": [ { "bytes": 18458, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "807ad64062599d9f8e0ca14c7d310a93440f3e7272ffc7cb04c778ab8c4c9d38" }, { "bytes": 8070, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a01610ead00df890de15445ef2b93fa81d9bff8d8ee01b8e18435fd38701c224" }, { "bytes": 7723, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "2a92e04b714af3f3fb194ecb1d1bab01785971ba0f048ae83a2826ab69ae46db" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089471/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089471", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7d93-95eb-07284913bf7d" } vhyb7BcEcVNyHzYhAKP65HMeC01xM+zBo4vrYIlInsUSBo6Xo3dBfrOjUm/N5nbCgEBUg3u8ZlUvmGx/LaveAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: vhyb7BcEcVNyHzYhAKP65HMeC01xM+zBo4vrYIlInsUSBo6Xo3dBfrOjUm/N5nbCgEBUg3u8ZlUvmGx/LaveAQ== {"files":[{"bytes":19264,"name":"index.html","sha256":"13938b825b142a3a2490ee767a1098b638285ce0bc4c62054e29810f4eee4c4b"},{"bytes":8758,"name":"publication.md","sha256":"8a586bdb0db50119453d9810ed8c0844c4af4687e15d3fd47d552a20f9708a57"},{"bytes":8412,"name":"publication.txt","sha256":"770fc3a0dc47c76647e522c720371151e940a21945aee6104c534eddbfd898fe"},{"bytes":2890,"name":"manifest.json","sha256":"ed9aed2570ace6b84ce34a3a4bf89e8e23e182ba63ff4f53a7ae427bf902ea6d"},{"bytes":89,"name":"manifest.sig","sha256":"ff1b04b7437411396cb8af7fc5e5a8f52876cbbbd427e9f1b87d165e500972fc"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3acfea565ee0186ba1a4bd45fad71c1812a378f57d8c29a35b3a707347cc599b"}],"publication_id":"OT-2026-000089472"} Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089472
OpenTechnical

OT-2026-000089472

Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
770fc3a0dc47c76647e522c720371151e940a21945aee6104c534eddbfd898fe

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089472, “Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089472.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089472" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089472" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089472 Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089472 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089472 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089472 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089472", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1216 }, "figures": [], "files": [ { "bytes": 19264, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "13938b825b142a3a2490ee767a1098b638285ce0bc4c62054e29810f4eee4c4b" }, { "bytes": 8758, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "8a586bdb0db50119453d9810ed8c0844c4af4687e15d3fd47d552a20f9708a57" }, { "bytes": 8412, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "770fc3a0dc47c76647e522c720371151e940a21945aee6104c534eddbfd898fe" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089472/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089472", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7063-9de0-286049b4ac57" } JP9Wdx3+2bKx0VIDBeXuXyiMRNBR0ko8gAHYEEIIDPlbP7YOQ3+lVM4ZBdzqdk5BrN322tlmks+ghSXxDfg9DQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: JP9Wdx3+2bKx0VIDBeXuXyiMRNBR0ko8gAHYEEIIDPlbP7YOQ3+lVM4ZBdzqdk5BrN322tlmks+ghSXxDfg9DQ== {"files":[{"bytes":19011,"name":"index.html","sha256":"d66f3a212d61d7d8df40c9a455f6eb72ae6981683c4946233c69971b0fc12f55"},{"bytes":8548,"name":"publication.md","sha256":"c23fcc3fb0ef3d90ac944ceabc11888886849837db03ddf4b8b7122c7c885eb0"},{"bytes":8202,"name":"publication.txt","sha256":"51e95d771f0165f223b0347d61f9e30a75acc8ad5a760808ded41fa3f9d7ab61"},{"bytes":2890,"name":"manifest.json","sha256":"19868df982a529f2279fcc03e8106cf95ccc745a283af6a22913aec5504af8be"},{"bytes":89,"name":"manifest.sig","sha256":"de69e457fdb8aa1e28597bba3e2e42550829be47c687cb62b627ab365cf509d4"},{"bytes":227,"name":"manifest.sig.txt","sha256":"238da4cbf2b9b5679b83209fe58a804798fedb4de70f3003a758559cd71e37ce"}],"publication_id":"OT-2026-000089473"} Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089473
OpenTechnical

OT-2026-000089473

Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
51e95d771f0165f223b0347d61f9e30a75acc8ad5a760808ded41fa3f9d7ab61

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089473, “Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089473.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089473" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089473" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089473 Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089473 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10259123-B2, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089473 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089473 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089473", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1181 }, "figures": [], "files": [ { "bytes": 19011, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d66f3a212d61d7d8df40c9a455f6eb72ae6981683c4946233c69971b0fc12f55" }, { "bytes": 8548, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c23fcc3fb0ef3d90ac944ceabc11888886849837db03ddf4b8b7122c7c885eb0" }, { "bytes": 8202, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "51e95d771f0165f223b0347d61f9e30a75acc8ad5a760808ded41fa3f9d7ab61" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089473/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089473", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7f9d-9001-a5a99b22ff44" } B0gAd25f9Z4xeNwvlDgLLhCLFL2wOnMxr1qOpnHbxZ30dbWYwxoJ/y6sCM/JKGTjawJyyd2PYi+33tclFcAgCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: B0gAd25f9Z4xeNwvlDgLLhCLFL2wOnMxr1qOpnHbxZ30dbWYwxoJ/y6sCM/JKGTjawJyyd2PYi+33tclFcAgCQ== {"files":[{"bytes":18212,"name":"index.html","sha256":"b5c230deec888a9322df9f2ee452a8cdc3b275f8d9d38f2df20bd23159c8154f"},{"bytes":7872,"name":"publication.md","sha256":"29408ae2b08c04e750aa03f684bb3126b3ca71c33c791086eb1ff478847395e6"},{"bytes":7523,"name":"publication.txt","sha256":"bc5320c730e53f1ecfd65135282a029c41fc06bd9a401a3f163138b83d9bb018"},{"bytes":2898,"name":"manifest.json","sha256":"482d06c1c1a5c2a59996d1f98c60af6684d52d64749c1be5bdad6f1d7f734a5c"},{"bytes":89,"name":"manifest.sig","sha256":"52cc9873781e9de54fd12b227f3637a33b417797089f873e3cb750e3b710858c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7bb07deeac64487893dfe0d2f543924e6faf9b7776fb43ee077706075f4a7f94"}],"publication_id":"OT-2026-000089474"} Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089474
OpenTechnical

OT-2026-000089474

Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
bc5320c730e53f1ecfd65135282a029c41fc06bd9a401a3f163138b83d9bb018

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089474, “Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089474.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089474" title: "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089474" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089474 Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089474 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089474 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089474 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089474", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1073 }, "figures": [], "files": [ { "bytes": 18212, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b5c230deec888a9322df9f2ee452a8cdc3b275f8d9d38f2df20bd23159c8154f" }, { "bytes": 7872, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "29408ae2b08c04e750aa03f684bb3126b3ca71c33c791086eb1ff478847395e6" }, { "bytes": 7523, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "bc5320c730e53f1ecfd65135282a029c41fc06bd9a401a3f163138b83d9bb018" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089474/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089474", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-753a-a14b-7417d02527a0" } HmAa2FKGkAbzTUjPaiYffFHqOoDHDT2eSmrTR5z/sNcq6J/E4/LOl1yQuemho19QVPEgUZ4+2L9rDiuYEqqODg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: HmAa2FKGkAbzTUjPaiYffFHqOoDHDT2eSmrTR5z/sNcq6J/E4/LOl1yQuemho19QVPEgUZ4+2L9rDiuYEqqODg== {"files":[{"bytes":19018,"name":"index.html","sha256":"42a79cbd60eeca7973bd622b94e959a24de4dee6844c45b6152189105e45f102"},{"bytes":8560,"name":"publication.md","sha256":"b506be2944111e918e4718c176e16b0d4893fda5a61086013b81a6e1fb4ba9d8"},{"bytes":8212,"name":"publication.txt","sha256":"656a77955f7c65fa2d31b8df24a1e6aa490bf83de721d65c6fb1a1463f33a9fa"},{"bytes":2903,"name":"manifest.json","sha256":"115d0e45d9b9747a856cac06025139dc311c9f59d5fd043d6ff936d2649a5293"},{"bytes":89,"name":"manifest.sig","sha256":"224aa7eb259783016ab466cf8fed143306a3ef23977567051241422748195d94"},{"bytes":227,"name":"manifest.sig.txt","sha256":"31f53aafa0f31eaeb75466752c8a494b47f9144d0a02433e75ccd7e8280551da"}],"publication_id":"OT-2026-000089475"} Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089475
OpenTechnical

OT-2026-000089475

Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
656a77955f7c65fa2d31b8df24a1e6aa490bf83de721d65c6fb1a1463f33a9fa

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089475, “Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089475.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089475" title: "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089475" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089475 Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089475 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089475 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089475 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089475", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1179 }, "figures": [], "files": [ { "bytes": 19018, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "42a79cbd60eeca7973bd622b94e959a24de4dee6844c45b6152189105e45f102" }, { "bytes": 8560, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b506be2944111e918e4718c176e16b0d4893fda5a61086013b81a6e1fb4ba9d8" }, { "bytes": 8212, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "656a77955f7c65fa2d31b8df24a1e6aa490bf83de721d65c6fb1a1463f33a9fa" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089475/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089475", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-77a1-a203-f930fe3be89d" } YWJ+DBNmxNR9iqDszHK9AMZaSv0Xmy7KvXAbkJE1Elh7zpw/MK2jX39rPRe1VvpGWT7xaqIm8zjXLm2dmLNrCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: YWJ+DBNmxNR9iqDszHK9AMZaSv0Xmy7KvXAbkJE1Elh7zpw/MK2jX39rPRe1VvpGWT7xaqIm8zjXLm2dmLNrCA== {"files":[{"bytes":18765,"name":"index.html","sha256":"8ebe72e6bca0cfa849d0dc1294d3136bc44a197d38e8863dfe10a8ea256e8d5a"},{"bytes":8350,"name":"publication.md","sha256":"2be740e1ff12e50413871e41583ca528a76a8c029a058046984b30cc82a27a9e"},{"bytes":8002,"name":"publication.txt","sha256":"df45e8f34fd7ad42d5ca90f73ea73f7d9a838fce559160b8e64c0ffa473b18c1"},{"bytes":2903,"name":"manifest.json","sha256":"3549502a37ab87e6e45f6cebdf9578e6df0814862061a62fe0c8c433f6371ae7"},{"bytes":89,"name":"manifest.sig","sha256":"176e6ace8f8160a863499fc0aa5c477795810631a16401553cdcdaf11bc0c4f9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f1f0aed19424d1702471ffc76279fc29c59f445b8516ee7b9027da55509f5151"}],"publication_id":"OT-2026-000089476"} Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089476
OpenTechnical

OT-2026-000089476

Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
df45e8f34fd7ad42d5ca90f73ea73f7d9a838fce559160b8e64c0ffa473b18c1

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089476, “Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089476.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089476" title: "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089476" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089476 Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089476 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089476 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089476 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089476", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1144 }, "figures": [], "files": [ { "bytes": 18765, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8ebe72e6bca0cfa849d0dc1294d3136bc44a197d38e8863dfe10a8ea256e8d5a" }, { "bytes": 8350, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "2be740e1ff12e50413871e41583ca528a76a8c029a058046984b30cc82a27a9e" }, { "bytes": 8002, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "df45e8f34fd7ad42d5ca90f73ea73f7d9a838fce559160b8e64c0ffa473b18c1" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089476/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089476", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7740-b81e-8507e5fd8116" } h3S9P8kdOTmaYIb8CEIWbHIpikmWsqavMFpPwPPJrVSMBmnkfjgNSiakvQWPDR0WLgA8AgU0mqC4Cdf7i7M6Cg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: h3S9P8kdOTmaYIb8CEIWbHIpikmWsqavMFpPwPPJrVSMBmnkfjgNSiakvQWPDR0WLgA8AgU0mqC4Cdf7i7M6Cg== {"files":[{"bytes":18212,"name":"index.html","sha256":"fee1b60aa7092b93dc3a9c82454c8d952da7e082c82cef89feccb89666f5fedf"},{"bytes":7872,"name":"publication.md","sha256":"5ffa70c00e267c7ab74467e8d579be4153954451dafae962e01b71182fc37687"},{"bytes":7523,"name":"publication.txt","sha256":"940cad74ffdb95afd24d709630a7807276da55ed228b37f024e68016b46affd3"},{"bytes":2898,"name":"manifest.json","sha256":"2b72be4ee363437f01a847aa0263645db3fab3757287baefbebc8e46f413ecaa"},{"bytes":89,"name":"manifest.sig","sha256":"d8030eb475a290b1b6327de4008086a0777c8a63dffdc95878bb3afdf3d76a75"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4826ee31985e24d3228ac29426c5529e5f16f4cf02f2dceaefd157dbec164ba0"}],"publication_id":"OT-2026-000089477"} Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089477
OpenTechnical

OT-2026-000089477

Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Supply
Document SHA-256
940cad74ffdb95afd24d709630a7807276da55ed228b37f024e68016b46affd3

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the mounting flange is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089477, “Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089477.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089477" title: "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089477" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089477 Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089477 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the mounting flange is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089477 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089477 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089477", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-components-safety-infrastructure/plant-utilities/vacuum-supply" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1073 }, "figures": [], "files": [ { "bytes": 18212, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "fee1b60aa7092b93dc3a9c82454c8d952da7e082c82cef89feccb89666f5fedf" }, { "bytes": 7872, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5ffa70c00e267c7ab74467e8d579be4153954451dafae962e01b71182fc37687" }, { "bytes": 7523, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "940cad74ffdb95afd24d709630a7807276da55ed228b37f024e68016b46affd3" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089477/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089477", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7982-ad89-1c64e50f8102" } Zvt/86C7UTviIOlLpFDVcCCmoJq7ACTH6qN0mtcd2PH0OdTwYUQin2QMjRL4DJ/xI+A+u919yX+6slgZVwunDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Zvt/86C7UTviIOlLpFDVcCCmoJq7ACTH6qN0mtcd2PH0OdTwYUQin2QMjRL4DJ/xI+A+u919yX+6slgZVwunDA== {"files":[{"bytes":19018,"name":"index.html","sha256":"6aa26115ab2235b952ed85e4593a936dbd83d4faa8c9475ddb0cc2ab592f71c4"},{"bytes":8560,"name":"publication.md","sha256":"f3abca91914c191e62899f74ef3b703e4a71365619311b7623d1ebd1c36cb09c"},{"bytes":8212,"name":"publication.txt","sha256":"8c424e9f33c0c7eb7b06f0b99594c1b48a4c754181c9c02eac878d284d8737f7"},{"bytes":2903,"name":"manifest.json","sha256":"bf4fce13eb358d09dca1ab118d4abbc10186b56d907c16f508fae1bc1aa48611"},{"bytes":89,"name":"manifest.sig","sha256":"93a256f4e7d247f0617964534d70fbacd4389b663348e073e19484106579f10b"},{"bytes":227,"name":"manifest.sig.txt","sha256":"183ea38fb65c5def1cd849efac05000c073605d65718483afeb3925414f7d9de"}],"publication_id":"OT-2026-000089478"} Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089478
OpenTechnical

OT-2026-000089478

Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8c424e9f33c0c7eb7b06f0b99594c1b48a4c754181c9c02eac878d284d8737f7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0020]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089478, “Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089478.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089478" title: "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089478" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089478 Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089478 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0020] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089478 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089478 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089478", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1179 }, "figures": [], "files": [ { "bytes": 19018, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6aa26115ab2235b952ed85e4593a936dbd83d4faa8c9475ddb0cc2ab592f71c4" }, { "bytes": 8560, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "f3abca91914c191e62899f74ef3b703e4a71365619311b7623d1ebd1c36cb09c" }, { "bytes": 8212, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8c424e9f33c0c7eb7b06f0b99594c1b48a4c754181c9c02eac878d284d8737f7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089478/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089478", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-75ae-9d92-bd229768f9a7" } 5Dg5ap/ZBGRM9GhEFYin5zXVdo4jur5LTGD1RCERFf7/sS/jFLitGXzdLmEeVfc9miZsMG221W399JvUmcqnAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 5Dg5ap/ZBGRM9GhEFYin5zXVdo4jur5LTGD1RCERFf7/sS/jFLitGXzdLmEeVfc9miZsMG221W399JvUmcqnAg== {"files":[{"bytes":18765,"name":"index.html","sha256":"51dcea9aba91f5406e9a56c905decc59d01f018f75b6120e3646105097d40043"},{"bytes":8350,"name":"publication.md","sha256":"3ad095411b465c2fc696efb4dcf50cc430591ed263c4f28e512dc72a8f8dff97"},{"bytes":8002,"name":"publication.txt","sha256":"265bc5abbc9085fc6b9248ac827058b2ac4fc333afb1196fc4a509ebfe225962"},{"bytes":2903,"name":"manifest.json","sha256":"2afe5a604bd845fc20355b91e60926f9f0bbe9d5dfa02575149e4d7a28418a3f"},{"bytes":89,"name":"manifest.sig","sha256":"eea490129a90569059d36d868455e25349e1adc5028753ef55c1386046ca203f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"4ef50c7b9abd726dfe5facb6cf17fc26bd7981db88e70d31161120ca64365ad4"}],"publication_id":"OT-2026-000089479"} Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089479
OpenTechnical

OT-2026-000089479

Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
265bc5abbc9085fc6b9248ac827058b2ac4fc333afb1196fc4a509ebfe225962

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold.

[0012]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0013]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0014]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0015]The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face.

[0016]The robot side of the tool-change interface is bolted to the robot flange.

[0017]The remaining one manifold outlet is plugged and carries no line.

[0018]The blow-off valve is fed from the compressed air supply of the cell.

[0019]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0020]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection.

[0021]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0022]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0023]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0024]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0025]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0026]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0027]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0028]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0029]The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089479, “Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089479.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089479" title: "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089479" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "plant vacuum connection" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One plant vacuum connection.** The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089479 Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089479 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a plant vacuum connection. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One plant vacuum connection. The plant vacuum connection takes vacuum from the plant line, so the tool carries no generator of its own. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The manifold inlet is connected to the plant vacuum connection, which supplies every outlet of the manifold. [0012] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0013] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0014] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0015] The blow-off valve is connected to the circuit at the plant vacuum connection, so that compressed air can be driven back through the circuit to the face. [0016] The robot side of the tool-change interface is bolted to the robot flange. [0017] The remaining one manifold outlet is plugged and carries no line. [0018] The blow-off valve is fed from the compressed air supply of the cell. [0019] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0020] - When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. [0021] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0022] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0023] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0024] - The workpiece is held until the blow-off valve has opened the circuit. [0025] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0026] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0027] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0028] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0029] The tool carries no valve between the plant line and the face, so the plant vacuum is applied to the face whenever the plant line is live; release relies on the release element alone. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10259123-B2, US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089479 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089479 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one plant vacuum connection, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the plant vacuum connection. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089479", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1144 }, "figures": [], "files": [ { "bytes": 18765, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "51dcea9aba91f5406e9a56c905decc59d01f018f75b6120e3646105097d40043" }, { "bytes": 8350, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3ad095411b465c2fc696efb4dcf50cc430591ed263c4f28e512dc72a8f8dff97" }, { "bytes": 8002, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "265bc5abbc9085fc6b9248ac827058b2ac4fc333afb1196fc4a509ebfe225962" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089479/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "plant vacuum connection", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089479", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, plant vacuum fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7f7f-8817-c9f9bee84716" } GsLuKDjEobiAQATVLdfqGIAia8zv9LFvMgAvE312zqhnDI6gUWNzD7b1koa1xrto6Sn2nohaSCuOmkWzpW2lAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: GsLuKDjEobiAQATVLdfqGIAia8zv9LFvMgAvE312zqhnDI6gUWNzD7b1koa1xrto6Sn2nohaSCuOmkWzpW2lAg== {"files":[{"bytes":18271,"name":"index.html","sha256":"9cedb61721c5d32b5aa96ebf0ebb5a99d5d16c4d289b60312bc33d6dc9101f86"},{"bytes":7872,"name":"publication.md","sha256":"220cc0f83727244e9c7466476c2d8a612a070dc462dcf1641f2ccfff4d9219e2"},{"bytes":7542,"name":"publication.txt","sha256":"81023ce270b34150b396dca4b359c4e3ae536b92714dd24fcf6a331ac816cf35"},{"bytes":2855,"name":"manifest.json","sha256":"62c874beef354288d92702002875b3f892365415f50dcf103538077dc6d1d1e0"},{"bytes":89,"name":"manifest.sig","sha256":"ee1829ff9a3bdf04100ea5b2991dfcda5fa5c5b1cc74eddd7659733d3c8eee64"},{"bytes":227,"name":"manifest.sig.txt","sha256":"37aa886ee7d4c55375a355a758f69125033b9802381a2c82a3d3c9a703ff6891"}],"publication_id":"OT-2026-000089480"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089480
OpenTechnical

OT-2026-000089480

Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
81023ce270b34150b396dca4b359c4e3ae536b92714dd24fcf6a331ac816cf35

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089480, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089480.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089480" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089480" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089480 Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089480 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089480 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089480 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089480", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1084 }, "figures": [], "files": [ { "bytes": 18271, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "9cedb61721c5d32b5aa96ebf0ebb5a99d5d16c4d289b60312bc33d6dc9101f86" }, { "bytes": 7872, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "220cc0f83727244e9c7466476c2d8a612a070dc462dcf1641f2ccfff4d9219e2" }, { "bytes": 7542, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "81023ce270b34150b396dca4b359c4e3ae536b92714dd24fcf6a331ac816cf35" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089480/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089480", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7bf0-94b6-9813f643a2e2" } F1hlwGgb5dm7pdBhYfjmHDftM4r4Do2v0SdtLt+/zXT2S5R5VU5vEAB0LMzmn+xvwjiNulAxlK1WZJtQ50EtBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: F1hlwGgb5dm7pdBhYfjmHDftM4r4Do2v0SdtLt+/zXT2S5R5VU5vEAB0LMzmn+xvwjiNulAxlK1WZJtQ50EtBw== {"files":[{"bytes":19086,"name":"index.html","sha256":"ae441e0315dc65492772456d9a2dbe55c38e88a9054d7d520508f74d3165de34"},{"bytes":8573,"name":"publication.md","sha256":"45dee89f3de9deb9eb25ca07104e56329917f6cc8e5f9cfef5b65c6b17653f5e"},{"bytes":8237,"name":"publication.txt","sha256":"5f49ebad6ce56c712431c7cdc248738906e224fe0680862e5acfdbd81e8d4914"},{"bytes":2867,"name":"manifest.json","sha256":"dbdcffe5950e7e3af34796bd6f4fd7985ccc89c27a58ec1ff1608ced03c72f8d"},{"bytes":89,"name":"manifest.sig","sha256":"2ccd0c8c4e4c7169ef614fee912952be7288da2c6dba7e3336eb18059670fd7e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b4744375778e4061b65b725727bdc9aa94f8573aca0b0ed1ec665711d60f9d46"}],"publication_id":"OT-2026-000089481"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089481
OpenTechnical

OT-2026-000089481

Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
5f49ebad6ce56c712431c7cdc248738906e224fe0680862e5acfdbd81e8d4914

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089481, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089481.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089481" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089481" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089481 Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089481 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089481 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089481 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089481", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1190 }, "figures": [], "files": [ { "bytes": 19086, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ae441e0315dc65492772456d9a2dbe55c38e88a9054d7d520508f74d3165de34" }, { "bytes": 8573, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "45dee89f3de9deb9eb25ca07104e56329917f6cc8e5f9cfef5b65c6b17653f5e" }, { "bytes": 8237, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "5f49ebad6ce56c712431c7cdc248738906e224fe0680862e5acfdbd81e8d4914" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089481/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089481", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-78f8-bae8-79da592ddd10" } aGmdQLLGPTaAPS37+k1ZXw/xoaraCtno146Sc5rZUHY+nidIejklAnQWfq81PPgVUTgl/gsVGnVKRoh1qp0eBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: aGmdQLLGPTaAPS37+k1ZXw/xoaraCtno146Sc5rZUHY+nidIejklAnQWfq81PPgVUTgl/gsVGnVKRoh1qp0eBg== {"files":[{"bytes":18833,"name":"index.html","sha256":"82a6c7f12edc08d84149cfcc81c164971269a6cdbf3d72893b06210891767697"},{"bytes":8363,"name":"publication.md","sha256":"9c82d41810ce491e08a6be3bedb2b92c61723f54d9043be69674c85d180876ca"},{"bytes":8027,"name":"publication.txt","sha256":"f841caa0abd9fe5c59f4395b918d32754282d3817d79bb3db4d7ab9b186018ea"},{"bytes":2867,"name":"manifest.json","sha256":"3665e1023c3d5a7d525bb9ddf48e9c3ff096e1b248ae30556fac39b992ba9edd"},{"bytes":89,"name":"manifest.sig","sha256":"cd97d77854868a335079fd710a44ec2d7a259e2bd833fa94f53026ce65b1c5c7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e3c7e7657018cdc52e56116c873411565105650b8cb959c497e32be015ae82ad"}],"publication_id":"OT-2026-000089482"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089482
OpenTechnical

OT-2026-000089482

Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f841caa0abd9fe5c59f4395b918d32754282d3817d79bb3db4d7ab9b186018ea

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089482, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089482.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089482" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089482" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089482 Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089482 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089482 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089482 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089482", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1155 }, "figures": [], "files": [ { "bytes": 18833, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "82a6c7f12edc08d84149cfcc81c164971269a6cdbf3d72893b06210891767697" }, { "bytes": 8363, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "9c82d41810ce491e08a6be3bedb2b92c61723f54d9043be69674c85d180876ca" }, { "bytes": 8027, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f841caa0abd9fe5c59f4395b918d32754282d3817d79bb3db4d7ab9b186018ea" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089482/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089482", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-785c-8ff2-9b57d232ce82" } 6yY93skmtpnwOctwbRSsR1pDWpjY0Kn/8VnX6hQY7FdXjyONs2gw/46a5HDypH8ZwXrQF7zoT7as5FfeJ4PEAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 6yY93skmtpnwOctwbRSsR1pDWpjY0Kn/8VnX6hQY7FdXjyONs2gw/46a5HDypH8ZwXrQF7zoT7as5FfeJ4PEAQ== {"files":[{"bytes":18272,"name":"index.html","sha256":"8ba2cad4326500f7cd2d974c10c705a10d8151d332198d3df6980c27b8d40736"},{"bytes":7873,"name":"publication.md","sha256":"34e81fa0c3106b474f705511275aa9358a921422db8ae8872ed5ce7c3e1639b3"},{"bytes":7543,"name":"publication.txt","sha256":"b5f5be68c3370e04c2e8609fea7911372c938a1090dc724d541b9fa19e5176f1"},{"bytes":2855,"name":"manifest.json","sha256":"92b59274f5755524b1f719cade32baaea58d81a8504c6ccd99d6bac95bf7ae00"},{"bytes":89,"name":"manifest.sig","sha256":"100fac1270d2b9e652d3edbd9229227baeb37f7a4a7a76e8cfba1f5f1f1af137"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b611ee7311a746a6ab7b451cf1f8aaeab9b09f3b3b8b300e5ed52903bca54778"}],"publication_id":"OT-2026-000089483"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089483
OpenTechnical

OT-2026-000089483

Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
b5f5be68c3370e04c2e8609fea7911372c938a1090dc724d541b9fa19e5176f1

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089483, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089483.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089483" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089483" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089483 Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089483 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089483 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089483 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089483", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1084 }, "figures": [], "files": [ { "bytes": 18272, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8ba2cad4326500f7cd2d974c10c705a10d8151d332198d3df6980c27b8d40736" }, { "bytes": 7873, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "34e81fa0c3106b474f705511275aa9358a921422db8ae8872ed5ce7c3e1639b3" }, { "bytes": 7543, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b5f5be68c3370e04c2e8609fea7911372c938a1090dc724d541b9fa19e5176f1" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089483/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089483", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7bc4-a5bd-a6a4389a6487" } IXetCDi4UL8ii5eSHojPPCeUSc0LYrbJTFi1iRT0SqovhPp0RCEub8y5xVw8sjE88CMsgr+qpEN5Cl5xlOCsAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: IXetCDi4UL8ii5eSHojPPCeUSc0LYrbJTFi1iRT0SqovhPp0RCEub8y5xVw8sjE88CMsgr+qpEN5Cl5xlOCsAw== {"files":[{"bytes":19087,"name":"index.html","sha256":"4021cc4c2d236c9fbc1814d4b2dc7526f1bcf004bd1a302424cc4c2fe6a4e19f"},{"bytes":8574,"name":"publication.md","sha256":"83321cb65fee70552cc6a6bd2d2e3b6998e2aad8987e329d8ba67415d6f22d02"},{"bytes":8238,"name":"publication.txt","sha256":"aeced56e356eb9d7a452ed605488526da86a7b916daa7ceb88a94b90617e0754"},{"bytes":2867,"name":"manifest.json","sha256":"03c84d75501f69ebb530d6c5e7a7709a7d6f9b864d00bd37450ac84ab4214b05"},{"bytes":89,"name":"manifest.sig","sha256":"765563bc61deca75cecfb845dde7cf6e86ab4d947aa5f9250001c275c65f6620"},{"bytes":227,"name":"manifest.sig.txt","sha256":"81f246c73a4dc4b5b6922972267a7e91eb1155874f856f3844d617d08d62654c"}],"publication_id":"OT-2026-000089484"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089484
OpenTechnical

OT-2026-000089484

Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
aeced56e356eb9d7a452ed605488526da86a7b916daa7ceb88a94b90617e0754

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089484, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089484.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089484" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089484" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089484 Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089484 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089484 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089484 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089484", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1190 }, "figures": [], "files": [ { "bytes": 19087, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "4021cc4c2d236c9fbc1814d4b2dc7526f1bcf004bd1a302424cc4c2fe6a4e19f" }, { "bytes": 8574, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "83321cb65fee70552cc6a6bd2d2e3b6998e2aad8987e329d8ba67415d6f22d02" }, { "bytes": 8238, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "aeced56e356eb9d7a452ed605488526da86a7b916daa7ceb88a94b90617e0754" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089484/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089484", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-728c-9e3d-a9a0d1da7ae6" } 6+EAXPNxWmSjmI7xHUyrqMtIo97awag358rlhjP7bYLmklCUshDx3OoH0b3lH9QMOk26HdgChLIVa2xtQ76fAg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 6+EAXPNxWmSjmI7xHUyrqMtIo97awag358rlhjP7bYLmklCUshDx3OoH0b3lH9QMOk26HdgChLIVa2xtQ76fAg== {"files":[{"bytes":18834,"name":"index.html","sha256":"d255cfd91082709c43e33b389ce61a5e37eff191cb348de67c5d806f4d61ffb3"},{"bytes":8364,"name":"publication.md","sha256":"fb631932d71930b97ce80e30b02ad97ecd7776c58e2414d6d389586a5fbbaa75"},{"bytes":8028,"name":"publication.txt","sha256":"8a756c3fe860cc732907e5573619341c1b07ace5ddd842f796d8a80315f0c6a4"},{"bytes":2867,"name":"manifest.json","sha256":"0c75d5faceecc67217365b6aeb0189ce740fef2f9f4639921796f32cb3ed6ff1"},{"bytes":89,"name":"manifest.sig","sha256":"50c41d29215c163dd0f18b5c15ac13c990e4b864adb82c483188446089c200de"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9c44da4a50ccbbb3b0dba81a5b65e848f65dde4e70344a2e99c2bd597f4bf5f6"}],"publication_id":"OT-2026-000089485"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089485
OpenTechnical

OT-2026-000089485

Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8a756c3fe860cc732907e5573619341c1b07ace5ddd842f796d8a80315f0c6a4

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089485, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089485.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089485" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089485" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089485 Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089485 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089485 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089485 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089485", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1155 }, "figures": [], "files": [ { "bytes": 18834, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d255cfd91082709c43e33b389ce61a5e37eff191cb348de67c5d806f4d61ffb3" }, { "bytes": 8364, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fb631932d71930b97ce80e30b02ad97ecd7776c58e2414d6d389586a5fbbaa75" }, { "bytes": 8028, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8a756c3fe860cc732907e5573619341c1b07ace5ddd842f796d8a80315f0c6a4" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089485/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089485", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7efc-901b-9b4163e9dc97" } sj/wlVMxzChXVof31NI2MaagxXMcaehFmLywOwua2kx6ndEdueqjub60LRnyKEKhXtRK0pYGt0DDXugPuKGqCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: sj/wlVMxzChXVof31NI2MaagxXMcaehFmLywOwua2kx6ndEdueqjub60LRnyKEKhXtRK0pYGt0DDXugPuKGqCw== {"files":[{"bytes":18276,"name":"index.html","sha256":"8e3b5c5ac3dc6f8144a61e0cffd03b226ccc9dc1fd4e8d27f93e589bb3038def"},{"bytes":7877,"name":"publication.md","sha256":"fb248fb31ed99f2988af7a068874449f98e98aef0af42d84b2b9e80e90efddf8"},{"bytes":7547,"name":"publication.txt","sha256":"9b097063a99c0328fdefa55a4affcbe6763437bf855bac418c801d29da9e1a4f"},{"bytes":2855,"name":"manifest.json","sha256":"bfe33154fe4776be84d4c6425c70ed517db67066ee66430c0bcd4b489b912fde"},{"bytes":89,"name":"manifest.sig","sha256":"78e7ca7682f38b9fc489f5fde2ef4e29b2142e00a7d11e95a18b39f0d1db7391"},{"bytes":227,"name":"manifest.sig.txt","sha256":"59e1cef548e0f7d1843a706005eaa6d64093102d5f0b99a8b1f54eed947da262"}],"publication_id":"OT-2026-000089486"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089486
OpenTechnical

OT-2026-000089486

Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
9b097063a99c0328fdefa55a4affcbe6763437bf855bac418c801d29da9e1a4f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089486, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089486.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089486" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089486" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089486 Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089486 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089486 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089486 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089486", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1084 }, "figures": [], "files": [ { "bytes": 18276, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8e3b5c5ac3dc6f8144a61e0cffd03b226ccc9dc1fd4e8d27f93e589bb3038def" }, { "bytes": 7877, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fb248fb31ed99f2988af7a068874449f98e98aef0af42d84b2b9e80e90efddf8" }, { "bytes": 7547, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9b097063a99c0328fdefa55a4affcbe6763437bf855bac418c801d29da9e1a4f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089486/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089486", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7dba-bada-e3b585ef7120" } DedKzRafK38/mcKxx5WY6/k8u8XBHHlXtW0GOE6OAOrdbwLkwsWHfeLgryhF3F5RLdWJIyzqsNm9Ymu9ML7YCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: DedKzRafK38/mcKxx5WY6/k8u8XBHHlXtW0GOE6OAOrdbwLkwsWHfeLgryhF3F5RLdWJIyzqsNm9Ymu9ML7YCw== {"files":[{"bytes":19091,"name":"index.html","sha256":"e67f03a7096f0538e47f426f3ec59a0f114387d88ebaffa0548088b93676552e"},{"bytes":8578,"name":"publication.md","sha256":"59ac5f47f3d0053bcc949661896792bf6cf27b3393e9b7a8ccbbbfb89c731f65"},{"bytes":8242,"name":"publication.txt","sha256":"a7a0045f01ba742b284c2bc1b155da48e58e0b8370f5d7c9805ad382e4c241f5"},{"bytes":2867,"name":"manifest.json","sha256":"cc172da80d728255acbc1e1d71c3300027f64bf48e71acd28f3deca0aac71c0f"},{"bytes":89,"name":"manifest.sig","sha256":"0d081cded8a9349ea4a0b063e2f820119060298defffb0b02520700fe98ca944"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0014c2567e236e2c6d2705c5a31d93cc81ce3a4a967707309431d3e9f2150086"}],"publication_id":"OT-2026-000089487"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089487
OpenTechnical

OT-2026-000089487

Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a7a0045f01ba742b284c2bc1b155da48e58e0b8370f5d7c9805ad382e4c241f5

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089487, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089487.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089487" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089487" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089487 Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089487 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089487 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089487 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089487", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1190 }, "figures": [], "files": [ { "bytes": 19091, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "e67f03a7096f0538e47f426f3ec59a0f114387d88ebaffa0548088b93676552e" }, { "bytes": 8578, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "59ac5f47f3d0053bcc949661896792bf6cf27b3393e9b7a8ccbbbfb89c731f65" }, { "bytes": 8242, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a7a0045f01ba742b284c2bc1b155da48e58e0b8370f5d7c9805ad382e4c241f5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089487/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089487", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7c93-b136-15f5c50b8ca9" } OYCCNS9EhSepfD8oy7ZAZAI32HtvVt2XQm/0DxCQgPmCo9AMgEhNjJ0K6ldaguZDCatsc27WIf5W/9Nx5domCA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: OYCCNS9EhSepfD8oy7ZAZAI32HtvVt2XQm/0DxCQgPmCo9AMgEhNjJ0K6ldaguZDCatsc27WIf5W/9Nx5domCA== {"files":[{"bytes":18838,"name":"index.html","sha256":"df38c8933b5414303e718603a4102c3543bb2a5633de4b58ba20f635657999a4"},{"bytes":8368,"name":"publication.md","sha256":"13cd56b5c698bee7388b457af5b01915ead3c104f3970a5c189d9065d13cda2d"},{"bytes":8032,"name":"publication.txt","sha256":"769ea0ddc9e69951b58e0340e53a449fa832b3b4592aa349b25fc379d12501b2"},{"bytes":2867,"name":"manifest.json","sha256":"66d5e56904bfdf45485f25896b8e5b142fd9fb5cb006f9e4e53e3f62c70a3134"},{"bytes":89,"name":"manifest.sig","sha256":"69a0ab7bbb31141a113094c2d03936589b5d08a5c139276a05597cbffbf5117a"},{"bytes":227,"name":"manifest.sig.txt","sha256":"25c31e343e6b932b7bca468bafceb5f97b4fede83a8acc35950f3724fa27db3c"}],"publication_id":"OT-2026-000089488"} Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089488
OpenTechnical

OT-2026-000089488

Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
769ea0ddc9e69951b58e0340e53a449fa832b3b4592aa349b25fc379d12501b2

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089488, “Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089488.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089488" title: "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089488" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089488 Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089488 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two bellows cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of two follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089488 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089488 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two bellows cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089488", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1155 }, "figures": [], "files": [ { "bytes": 18838, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "df38c8933b5414303e718603a4102c3543bb2a5633de4b58ba20f635657999a4" }, { "bytes": 8368, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "13cd56b5c698bee7388b457af5b01915ead3c104f3970a5c189d9065d13cda2d" }, { "bytes": 8032, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "769ea0ddc9e69951b58e0340e53a449fa832b3b4592aa349b25fc379d12501b2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089488/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089488", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two bellows cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7f34-b81e-0b04ec29dfd8" } QXQ4T+D5FEaDPsGZbYjg0LQmGH80CWZ1S7iZBFO0/2mgVy3pTtDFY/kxusOnK9qwZJU2SnvtZtP2re2gEOO+Bw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: QXQ4T+D5FEaDPsGZbYjg0LQmGH80CWZ1S7iZBFO0/2mgVy3pTtDFY/kxusOnK9qwZJU2SnvtZtP2re2gEOO+Bw== {"files":[{"bytes":18465,"name":"index.html","sha256":"b3bf8c36953084d361fecf5bfabafdc2387e86707c190ef23fb3739e876e3251"},{"bytes":8034,"name":"publication.md","sha256":"398572ad621708b12cf8e4c2df3ce636424aa61cb54efa1ae2aba876ae126038"},{"bytes":7714,"name":"publication.txt","sha256":"1d816d5d90d371a0238202712afa66c64edaa0e6dcdfd501c0ac9a77d66aee14"},{"bytes":2834,"name":"manifest.json","sha256":"657b4e26bbcc829afc8c0e4ed835510259193576995b746de9ca3fb5e47de23e"},{"bytes":89,"name":"manifest.sig","sha256":"4051027648c95b8f95568ecd381b5cdcd63fbecf3c7c542de5c0e7add3ccb7f1"},{"bytes":227,"name":"manifest.sig.txt","sha256":"79ca0b2544d4d1e41e4a951d9415e2a26fca2468991c2bb281f82690e13295ad"}],"publication_id":"OT-2026-000089489"} Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089489
OpenTechnical

OT-2026-000089489

Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
1d816d5d90d371a0238202712afa66c64edaa0e6dcdfd501c0ac9a77d66aee14

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089489, “Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089489.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089489" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089489" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089489 Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089489 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089489 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089489 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089489", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1124 }, "figures": [], "files": [ { "bytes": 18465, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b3bf8c36953084d361fecf5bfabafdc2387e86707c190ef23fb3739e876e3251" }, { "bytes": 8034, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "398572ad621708b12cf8e4c2df3ce636424aa61cb54efa1ae2aba876ae126038" }, { "bytes": 7714, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1d816d5d90d371a0238202712afa66c64edaa0e6dcdfd501c0ac9a77d66aee14" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089489/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089489", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-77b6-a739-728b12990c5f" } H8bBiUnsNc6ypWzlpwGcAU1x0BAzA4csA+2Qk2pAa8lSHW/aJhSLutmNkbmfdOpWCKw94wGhWYmUMfuORgacCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: H8bBiUnsNc6ypWzlpwGcAU1x0BAzA4csA+2Qk2pAa8lSHW/aJhSLutmNkbmfdOpWCKw94wGhWYmUMfuORgacCQ== {"files":[{"bytes":19280,"name":"index.html","sha256":"b82c17682f4f1d8fa8797043235b5077127ac30ddf9606e9afab3d1508a10373"},{"bytes":8735,"name":"publication.md","sha256":"b72a9be7ca01fb2155f3735a83e087e7cfbfaa295cad8bcd1595ab3d1ca4f940"},{"bytes":8409,"name":"publication.txt","sha256":"84d8a08e6d24818b12d89716d63058eb00b046ae7b44f738adc10115099bccef"},{"bytes":2846,"name":"manifest.json","sha256":"83be511f93e24ca10583e174c99aec5a3592c17be149106ada075fe8dd5f2d7a"},{"bytes":89,"name":"manifest.sig","sha256":"d052ba1b0f153df32fbfdee06ac0b8a807f3f9e65fea89b35446440e06d4a742"},{"bytes":227,"name":"manifest.sig.txt","sha256":"61f68d1ed0f932bbeb0c29608d7cff6e468757046aa4be297c1801c4b7bf2d63"}],"publication_id":"OT-2026-000089490"} Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089490
OpenTechnical

OT-2026-000089490

Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
84d8a08e6d24818b12d89716d63058eb00b046ae7b44f738adc10115099bccef

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089490, “Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089490.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089490" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089490" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089490 Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089490 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089490 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089490 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089490", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1230 }, "figures": [], "files": [ { "bytes": 19280, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b82c17682f4f1d8fa8797043235b5077127ac30ddf9606e9afab3d1508a10373" }, { "bytes": 8735, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b72a9be7ca01fb2155f3735a83e087e7cfbfaa295cad8bcd1595ab3d1ca4f940" }, { "bytes": 8409, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "84d8a08e6d24818b12d89716d63058eb00b046ae7b44f738adc10115099bccef" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089490/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089490", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7a14-8fba-556cab218d0f" } ARGvxYb8j71RKR2/9HnYWN4zZniKc0g9VjAOIQrkhwrCuxZp9T7AJYfDgMfcSUbPlBcRTNzHzTxx4MYH1CPODQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ARGvxYb8j71RKR2/9HnYWN4zZniKc0g9VjAOIQrkhwrCuxZp9T7AJYfDgMfcSUbPlBcRTNzHzTxx4MYH1CPODQ== {"files":[{"bytes":19027,"name":"index.html","sha256":"7a38ad3e08870e89534e5cb687a860070430c7e1be0defd73287ea3372400a48"},{"bytes":8525,"name":"publication.md","sha256":"2d1d72ddec68bf04ddafd531d1316efa5507654889235bce2f8df210d9cd8b14"},{"bytes":8199,"name":"publication.txt","sha256":"4eaa6e5280f097e776e14fc70b60785f82b1d4b90a7c14852d80d7bbf51d484b"},{"bytes":2846,"name":"manifest.json","sha256":"2081ae0c20c0463036ec9b74b60d4d7a9ea702400ca901cdd9f070f92f629fd2"},{"bytes":89,"name":"manifest.sig","sha256":"ab1379163d0fc3c9878e2763ff266836c53ef7dffd493e2f0bf82654174fe6d5"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e91bab11430f40e47b3f40d44674f415ab0f9e77e39977e7920146c4ff187a4d"}],"publication_id":"OT-2026-000089491"} Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089491
OpenTechnical

OT-2026-000089491

Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
4eaa6e5280f097e776e14fc70b60785f82b1d4b90a7c14852d80d7bbf51d484b

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089491, “Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089491.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089491" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089491" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089491 Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089491 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089491 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089491 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089491", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1195 }, "figures": [], "files": [ { "bytes": 19027, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "7a38ad3e08870e89534e5cb687a860070430c7e1be0defd73287ea3372400a48" }, { "bytes": 8525, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "2d1d72ddec68bf04ddafd531d1316efa5507654889235bce2f8df210d9cd8b14" }, { "bytes": 8199, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4eaa6e5280f097e776e14fc70b60785f82b1d4b90a7c14852d80d7bbf51d484b" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089491/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089491", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7f5c-b9fd-626c7afee23c" } htdjdscJ8gziM2psf5fGq3EjdQ7delcPvWir+YMgsJ795/B3g/HSuW+gU+lztZJfrmEXLqWXmQ+bfwa5uSjtDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: htdjdscJ8gziM2psf5fGq3EjdQ7delcPvWir+YMgsJ795/B3g/HSuW+gU+lztZJfrmEXLqWXmQ+bfwa5uSjtDg== {"files":[{"bytes":18411,"name":"index.html","sha256":"89fbf8f3688f005d41ba1eb5c0747bac3618157b6ae7481d2329b15668436350"},{"bytes":7980,"name":"publication.md","sha256":"e7c5317145bc86295748c5479eba827a778c3b1bfb8a31959f6616546d6e3541"},{"bytes":7660,"name":"publication.txt","sha256":"1fdf46f7f4338586934ef6946cc6dbffd07136a85d1cfe6e4efb729cfaed196f"},{"bytes":2834,"name":"manifest.json","sha256":"209d7862ed6ab66f51c0bc27d03ecac6b95a48548d2f5b289da2a44be21c147b"},{"bytes":89,"name":"manifest.sig","sha256":"cce84b769a20f6fe497761a1cee9d8e6bd80d099f68d6463a2f785a8e8fcc339"},{"bytes":227,"name":"manifest.sig.txt","sha256":"3e004c14c01cb1ee9b829f136c238a5d387f0096f2e1bbdf328b080a5b18eb88"}],"publication_id":"OT-2026-000089492"} Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089492
OpenTechnical

OT-2026-000089492

Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
1fdf46f7f4338586934ef6946cc6dbffd07136a85d1cfe6e4efb729cfaed196f

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089492, “Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089492.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089492" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089492" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089492 Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089492 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089492 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089492 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089492", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1109 }, "figures": [], "files": [ { "bytes": 18411, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "89fbf8f3688f005d41ba1eb5c0747bac3618157b6ae7481d2329b15668436350" }, { "bytes": 7980, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e7c5317145bc86295748c5479eba827a778c3b1bfb8a31959f6616546d6e3541" }, { "bytes": 7660, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "1fdf46f7f4338586934ef6946cc6dbffd07136a85d1cfe6e4efb729cfaed196f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089492/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089492", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7c02-a6ab-75dd98d59edc" } ouAnvYmEyRrzAjVysOZFnT4SMvQN2/VO+1sDHJZ/OCNvIjzUIyguQmPRuVqKWqXx1il/8vAupv1B+ss8EpDTCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ouAnvYmEyRrzAjVysOZFnT4SMvQN2/VO+1sDHJZ/OCNvIjzUIyguQmPRuVqKWqXx1il/8vAupv1B+ss8EpDTCw== {"files":[{"bytes":19226,"name":"index.html","sha256":"c1ce55edb97157360d2c4c649579d7578c84b0213012e477a484e93cab360176"},{"bytes":8681,"name":"publication.md","sha256":"82c9735ebe50d71c51b9049eb59389564733834d747aed794205a194c8d662ca"},{"bytes":8355,"name":"publication.txt","sha256":"420f440dede2cb8dc42d0910b295eb02a128b04f3565c9b86d98f9c65681dae7"},{"bytes":2846,"name":"manifest.json","sha256":"9d714b976018c01fdc69d0a5b8959fd58a4c01c2787b51d5514961a992a2d5e6"},{"bytes":89,"name":"manifest.sig","sha256":"16639bd3afd9d622564cc030c5bd811892b17ba6ed86ad8c58003378f32019a6"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7ef143dbb71d1bb021ebb92779a05ef0375b6cc58399472b8657576222f63779"}],"publication_id":"OT-2026-000089493"} Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089493
OpenTechnical

OT-2026-000089493

Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
420f440dede2cb8dc42d0910b295eb02a128b04f3565c9b86d98f9c65681dae7

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0033]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0034]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0035]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089493, “Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089493.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089493" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089493" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089493 Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089493 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0033] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0034] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0035] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089493 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089493 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089493", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 35, "words": 1215 }, "figures": [], "files": [ { "bytes": 19226, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "c1ce55edb97157360d2c4c649579d7578c84b0213012e477a484e93cab360176" }, { "bytes": 8681, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "82c9735ebe50d71c51b9049eb59389564733834d747aed794205a194c8d662ca" }, { "bytes": 8355, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "420f440dede2cb8dc42d0910b295eb02a128b04f3565c9b86d98f9c65681dae7" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089493/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089493", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-79e4-8dc2-178f22a83e98" } Q9kABkSsUBrBLJRxm3GjyD0xqZhfLUZKkMsFpbvQfgYrWmfkPLAyoPrbie3RjlqN4q5xSA+OvhanotE7qAGrAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Q9kABkSsUBrBLJRxm3GjyD0xqZhfLUZKkMsFpbvQfgYrWmfkPLAyoPrbie3RjlqN4q5xSA+OvhanotE7qAGrAQ== {"files":[{"bytes":18973,"name":"index.html","sha256":"99a23dc0d66dc10ea8f19e1c7a8702cfb7a014637b529addc920efeef32188e5"},{"bytes":8471,"name":"publication.md","sha256":"110a7a46ed4ba36a4be09f89185fb828063fe5a20c60376a419ae3065f91d50f"},{"bytes":8145,"name":"publication.txt","sha256":"a34b67828f12718494c5ff2a349b2e16afaa9405f7526effe073a27647119f02"},{"bytes":2846,"name":"manifest.json","sha256":"2db40fc0854e3f05043d3fdd6323a80a54a2392af1ffcd286e830285ce469cf9"},{"bytes":89,"name":"manifest.sig","sha256":"62c70350f96ed1abf32ecff7f1df1f764a18e730d7d8b80a2a220fd89d504b90"},{"bytes":227,"name":"manifest.sig.txt","sha256":"78f814c5115b87b36e06fc910dd759c104666babf824ddc1f9c28e93bb9a5593"}],"publication_id":"OT-2026-000089494"} Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089494
OpenTechnical

OT-2026-000089494

Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a34b67828f12718494c5ff2a349b2e16afaa9405f7526effe073a27647119f02

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089494, “Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089494.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089494" title: "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089494" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089494 Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089494 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089494 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089494 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089494", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1180 }, "figures": [], "files": [ { "bytes": 18973, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "99a23dc0d66dc10ea8f19e1c7a8702cfb7a014637b529addc920efeef32188e5" }, { "bytes": 8471, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "110a7a46ed4ba36a4be09f89185fb828063fe5a20c60376a419ae3065f91d50f" }, { "bytes": 8145, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a34b67828f12718494c5ff2a349b2e16afaa9405f7526effe073a27647119f02" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089494/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089494", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-702c-95c5-4c335e412011" } gjjwW+iYeuRVp6/t8t9Dfj1GccbdQOe5DwejebNdW1ctpBeTE91D1c5blL+Espc2Wi5mEIszGKXvYXrfz1PjDg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: gjjwW+iYeuRVp6/t8t9Dfj1GccbdQOe5DwejebNdW1ctpBeTE91D1c5blL+Espc2Wi5mEIszGKXvYXrfz1PjDg== {"files":[{"bytes":18165,"name":"index.html","sha256":"b05a380556760e9d613e44b5d347ccbbcc7c77a702b75f600ee510beb67b0880"},{"bytes":7782,"name":"publication.md","sha256":"5d98825b7f9aa12196587f412ac0e2a5d250d197be639f92f5f8939bed93c7f8"},{"bytes":7460,"name":"publication.txt","sha256":"74876837b3538f0d03c04ac12af536dac4b6c3f8e2ad1436fee09248a09b3af3"},{"bytes":2847,"name":"manifest.json","sha256":"0ba855d5dcdf75cb3e689987b706d9e8fb6c1d6a08586b59502b4bee058d6734"},{"bytes":89,"name":"manifest.sig","sha256":"8ff605627f25a05b10d859f037b59c2efb52c17bf55bc4fdd950f69b6ff0075c"},{"bytes":227,"name":"manifest.sig.txt","sha256":"6187565f751dda0cd0e161538f81987924c3b346e545ed4e4212603c7d1ac0fa"}],"publication_id":"OT-2026-000089495"} Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089495
OpenTechnical

OT-2026-000089495

Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
74876837b3538f0d03c04ac12af536dac4b6c3f8e2ad1436fee09248a09b3af3

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089495, “Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089495.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089495" title: "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089495" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089495 Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089495 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089495 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089495 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089495", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1072 }, "figures": [], "files": [ { "bytes": 18165, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b05a380556760e9d613e44b5d347ccbbcc7c77a702b75f600ee510beb67b0880" }, { "bytes": 7782, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5d98825b7f9aa12196587f412ac0e2a5d250d197be639f92f5f8939bed93c7f8" }, { "bytes": 7460, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "74876837b3538f0d03c04ac12af536dac4b6c3f8e2ad1436fee09248a09b3af3" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089495/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089495", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-745b-ae9c-f71e522be2a7" } LM96fDYXO/kXrwCgoMvb8O4Gs4xU37IMQLEUC/ktuW5oaZcPUrz6D/qbtub2PiVhaxWCiCefRF/tb1dlML8NAQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: LM96fDYXO/kXrwCgoMvb8O4Gs4xU37IMQLEUC/ktuW5oaZcPUrz6D/qbtub2PiVhaxWCiCefRF/tb1dlML8NAQ== {"files":[{"bytes":18980,"name":"index.html","sha256":"62e240c90790b4c8d30f31bb69ed9574e7e4a523e7dfc2cbcf65f276775d6000"},{"bytes":8483,"name":"publication.md","sha256":"b0f3a45dc2edde760c0c11cdf9190672f9c4b72fb9c1523be83c140d2ac10b58"},{"bytes":8155,"name":"publication.txt","sha256":"9f0a503cc8bc21e8ad1c6ae741b2bec9646a7212960823bd07d0d066b75ad95e"},{"bytes":2859,"name":"manifest.json","sha256":"ed91da017f851a57547849ae79a0e2f9147fcab1035ab283aba37d7f5bf1ad3c"},{"bytes":89,"name":"manifest.sig","sha256":"2bbff565c8e97197ec01e81e229866d9a39500ce2e74f5b082cbe26af7669e0f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a6984ef6a68efcd03290544a49941dcec89c85ee34fef467fff6b03bba2aa0e5"}],"publication_id":"OT-2026-000089496"} Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089496
OpenTechnical

OT-2026-000089496

Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
9f0a503cc8bc21e8ad1c6ae741b2bec9646a7212960823bd07d0d066b75ad95e

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089496, “Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089496.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089496" title: "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089496" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089496 Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089496 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089496 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089496 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089496", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1178 }, "figures": [], "files": [ { "bytes": 18980, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "62e240c90790b4c8d30f31bb69ed9574e7e4a523e7dfc2cbcf65f276775d6000" }, { "bytes": 8483, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b0f3a45dc2edde760c0c11cdf9190672f9c4b72fb9c1523be83c140d2ac10b58" }, { "bytes": 8155, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9f0a503cc8bc21e8ad1c6ae741b2bec9646a7212960823bd07d0d066b75ad95e" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089496/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089496", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7a61-a2d1-3dbe97363061" } zPe5XK9TTOPHvg06HZ40yvcRD2qOpKEBduxYhmDqtNQ2SNZLX7ZRgGIo8fxMHIuTGsAHnnDEHCCXx03Qp1ckAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: zPe5XK9TTOPHvg06HZ40yvcRD2qOpKEBduxYhmDqtNQ2SNZLX7ZRgGIo8fxMHIuTGsAHnnDEHCCXx03Qp1ckAw== {"files":[{"bytes":18727,"name":"index.html","sha256":"2c41af65df2b62df74694f21fb9d59780a7146c2ec59652e59ee8c272224ae50"},{"bytes":8273,"name":"publication.md","sha256":"328d776d57c254c3ea8915855150e586daa2f13f41ecac4cd7192112243e7a5c"},{"bytes":7945,"name":"publication.txt","sha256":"e6c46b1494fb6827151451f3f2a11d519dbd414425d46906f154295c14151580"},{"bytes":2859,"name":"manifest.json","sha256":"57dd97da4ce7b1171d3a7e43c385947d5a05f60d944ed5f4362afa5e2fd1b75a"},{"bytes":89,"name":"manifest.sig","sha256":"56a7eaa324fdbe75a68ca5a0bb16e8a4a09e77a8abacbb5f3f33a8daad3c89c3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"07dbfde38e5be73974f63aae6adb65e7e853f7aab9270c6eadfa3d3e69ef8104"}],"publication_id":"OT-2026-000089497"} Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089497
OpenTechnical

OT-2026-000089497

Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
e6c46b1494fb6827151451f3f2a11d519dbd414425d46906f154295c14151580

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089497, “Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089497.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089497" title: "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089497" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089497 Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089497 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089497 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089497 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089497", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1143 }, "figures": [], "files": [ { "bytes": 18727, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2c41af65df2b62df74694f21fb9d59780a7146c2ec59652e59ee8c272224ae50" }, { "bytes": 8273, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "328d776d57c254c3ea8915855150e586daa2f13f41ecac4cd7192112243e7a5c" }, { "bytes": 7945, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e6c46b1494fb6827151451f3f2a11d519dbd414425d46906f154295c14151580" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089497/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089497", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7e95-9751-b70732547fac" } nG0SDi1o2UrHFXgaElqq5qQCP46ICmKiw1PfDUM4SEfs3pgmpxy3vFBygSVKProaV6jkE4RuWRppC0Om3jFUCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: nG0SDi1o2UrHFXgaElqq5qQCP46ICmKiw1PfDUM4SEfs3pgmpxy3vFBygSVKProaV6jkE4RuWRppC0Om3jFUCw== {"files":[{"bytes":18165,"name":"index.html","sha256":"91ca5b27910cab043517cded6b74cee6e3c8bf29313d312e4fbc2aefdffc0ff7"},{"bytes":7782,"name":"publication.md","sha256":"0828431673ef2ee4fc4a5dde0613ca36962e93f4de4647e859f021404d39d21b"},{"bytes":7460,"name":"publication.txt","sha256":"fb12f3e95a23f9795631f785f238afaaef292febb4fd78159faf38068f80ae49"},{"bytes":2847,"name":"manifest.json","sha256":"cd6281025dccdb5ba079752dfbc50102786fd057fe1f18ca9c5c638a4f2f76d7"},{"bytes":89,"name":"manifest.sig","sha256":"dcf392da500ee057c1534cc7fc97c8d84d417a36dcc5a684dbcbfc752f572630"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c3ce7eaf9b334bf89e357d6aa8fa2685cebeaa2357da8cfa6e9a02baf22249d5"}],"publication_id":"OT-2026-000089498"} Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089498
OpenTechnical

OT-2026-000089498

Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
fb12f3e95a23f9795631f785f238afaaef292febb4fd78159faf38068f80ae49

Abstract

A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The vacuum pump is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089498, “Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089498.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089498" title: "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089498" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089498 Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089498 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a mounting flange, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The vacuum pump is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089498 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089498 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089498", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1072 }, "figures": [], "files": [ { "bytes": 18165, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "91ca5b27910cab043517cded6b74cee6e3c8bf29313d312e4fbc2aefdffc0ff7" }, { "bytes": 7782, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0828431673ef2ee4fc4a5dde0613ca36962e93f4de4647e859f021404d39d21b" }, { "bytes": 7460, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fb12f3e95a23f9795631f785f238afaaef292febb4fd78159faf38068f80ae49" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089498/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089498", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-703b-a5cc-7624095c5946" } Mn7lqx1pav2w7iuR2r0PRR7AMMjDUtMMmh0O/AEmF/Qsy4ZS3FfqJCscnBtcaTomhIK2PXP5Gz8mMCGKynVDDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Mn7lqx1pav2w7iuR2r0PRR7AMMjDUtMMmh0O/AEmF/Qsy4ZS3FfqJCscnBtcaTomhIK2PXP5Gz8mMCGKynVDDw== {"files":[{"bytes":18980,"name":"index.html","sha256":"3ec7a4abc63539b1001573fdd7aa7c2842faae4bb029bd932d9ac559ded22ac3"},{"bytes":8483,"name":"publication.md","sha256":"0891b4ba87a246c923bb604624694c3a33af0ee4eb632d133544593c13c7223f"},{"bytes":8155,"name":"publication.txt","sha256":"3e99cd23910d39183ce4a6c98745c2f395f57c6c7548414c9627d84f273a4658"},{"bytes":2859,"name":"manifest.json","sha256":"f8cd726e4f649e4a353665c0725efa98d4ac1d1782a7daf818802658d3357b08"},{"bytes":89,"name":"manifest.sig","sha256":"0ac4baa4b11b1a9c16c8c1013c5bf2a9b5b0b8e2b6d99230bcf09ec2adfa5baf"},{"bytes":227,"name":"manifest.sig.txt","sha256":"f8bcdf269ebc1ebf8472addf67da3f31b3a01dc5df5c49b1b244bf0bb7c88971"}],"publication_id":"OT-2026-000089499"} Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089499
OpenTechnical

OT-2026-000089499

Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
3e99cd23910d39183ce4a6c98745c2f395f57c6c7548414c9627d84f273a4658

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0022]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0023]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0024]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0025]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0026]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0027]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0028]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0029]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0030]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0031]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089499, “Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089499.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089499" title: "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089499" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089499 Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089499 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0022] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0023] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0024] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0025] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0026] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0027] - The workpiece is held until the blow-off valve has opened the circuit. [0028] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0029] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0030] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0031] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089499 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089499 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089499", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1178 }, "figures": [], "files": [ { "bytes": 18980, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3ec7a4abc63539b1001573fdd7aa7c2842faae4bb029bd932d9ac559ded22ac3" }, { "bytes": 8483, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0891b4ba87a246c923bb604624694c3a33af0ee4eb632d133544593c13c7223f" }, { "bytes": 8155, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3e99cd23910d39183ce4a6c98745c2f395f57c6c7548414c9627d84f273a4658" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089499/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089499", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7099-8205-76aff5b08485" } FfOsMqVh5vzTCFgkQxgBcG6pXpFPg0dWlz57xkT7bjjUY8jLxMt7270/xSWQPoWxGAM/QK5/2O15PYAL9e/8BQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: FfOsMqVh5vzTCFgkQxgBcG6pXpFPg0dWlz57xkT7bjjUY8jLxMt7270/xSWQPoWxGAM/QK5/2O15PYAL9e/8BQ== {"files":[{"bytes":18727,"name":"index.html","sha256":"bc50fcb13a112518048a296fe4a195ac8ca82964a7bdb307fe46c529265be816"},{"bytes":8273,"name":"publication.md","sha256":"4e2b4a30360ec1aabc6e241627510cf98f759301733cdfa9f7cd88d94b4003d2"},{"bytes":7945,"name":"publication.txt","sha256":"c54448a58b32d4d75e4854b8692e6c2649862711d5be21e809609702b212ddbb"},{"bytes":2859,"name":"manifest.json","sha256":"eaf4108547b5d5dfc19441d00937183db5f850b3885c010d71f5c1d50e52d156"},{"bytes":89,"name":"manifest.sig","sha256":"6fd436658124c3fc9094209a8ed06b5dd77c89c7ed2471db61ecc201487250bc"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7b149fae8c5b479c8695e2cdf226c0bc65947dab664f6ca88fc91c3c43dba0ac"}],"publication_id":"OT-2026-000089500"} Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089500
OpenTechnical

OT-2026-000089500

Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c54448a58b32d4d75e4854b8692e6c2649862711d5be21e809609702b212ddbb

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The vacuum pump is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold.

[0013]Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The pump motor is supplied from the electrical supply of the cell.

[0019]The remaining one manifold outlet is plugged and carries no line.

[0020]The blow-off valve is fed from the compressed air supply of the cell.

[0021]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089500, “Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089500.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089500" title: "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089500" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "vacuum pump" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Two suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One vacuum pump.** The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Two zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089500 Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089500 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: two suction cups carried on a tool-change interface, fed by a vacuum pump. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Two suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of two follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One vacuum pump. The pump draws the circuit down mechanically and adds its own mass to the moving assembly. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Two zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of two follows from the arrangement: one branch per zone. The distribution is divided into two zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The vacuum pump is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the pump inlet line, which supplies every outlet of the manifold. [0013] Each of the two zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the pump inlet line, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The pump motor is supplied from the electrical supply of the cell. [0019] The remaining one manifold outlet is plugged and carries no line. [0020] The blow-off valve is fed from the compressed air supply of the cell. [0021] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); drive medium of the vacuum pump: electric (sets the supply the pump motor needs from the cell); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: two (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089500 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089500 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, two suction cups, one vacuum pump, one manifold, two zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the vacuum pump. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089500", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1143 }, "figures": [], "files": [ { "bytes": 18727, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bc50fcb13a112518048a296fe4a195ac8ca82964a7bdb307fe46c529265be816" }, { "bytes": 8273, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "4e2b4a30360ec1aabc6e241627510cf98f759301733cdfa9f7cd88d94b4003d2" }, { "bytes": 7945, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c54448a58b32d4d75e4854b8692e6c2649862711d5be21e809609702b212ddbb" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089500/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "vacuum pump", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089500", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Two cup vacuum gripper, two zone face, three outlet manifold, pump fed, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-72bf-8cb8-f8399cef4a05" } KlUUFUcT3RsQnLkvjzoo6ssiGFqGiMhzeQdZLaVF8yOzTrTHWcCynzrtdKrDdhgfDVTp+gvoPI87c6jLdwmBDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: KlUUFUcT3RsQnLkvjzoo6ssiGFqGiMhzeQdZLaVF8yOzTrTHWcCynzrtdKrDdhgfDVTp+gvoPI87c6jLdwmBDQ== {"files":[{"bytes":18345,"name":"index.html","sha256":"f4fa28ef1ed8e387204aa0b21ee4acd04ceb300aebec7178eb47799a13edfa17"},{"bytes":7953,"name":"publication.md","sha256":"70516a1374d183a9b142db08a19335232a7099f5a69f1798e43dc52a87e42958"},{"bytes":7611,"name":"publication.txt","sha256":"6fa416f99c3a54bb75e356eab33f6fbdbfe38f05f4739c33ef9f2cb76b7c0ee5"},{"bytes":2863,"name":"manifest.json","sha256":"d8739be5df1aa58538ae4b0801df9b56b489e86fd2974a5eba0f43f6828c4243"},{"bytes":89,"name":"manifest.sig","sha256":"0190ad15335ba9df4d8f775e62e6f5255680abc1c34f5f6ee284e969d21cbaaa"},{"bytes":227,"name":"manifest.sig.txt","sha256":"8160dd900b3a4218fe7d1d4b221193bb44c040c6c197f4bc3366c0e8377029cc"}],"publication_id":"OT-2026-000089501"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089501
OpenTechnical

OT-2026-000089501

Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
6fa416f99c3a54bb75e356eab33f6fbdbfe38f05f4739c33ef9f2cb76b7c0ee5

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089501, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089501.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089501" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089501" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089501 Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089501 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089501 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089501 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089501", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18345, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f4fa28ef1ed8e387204aa0b21ee4acd04ceb300aebec7178eb47799a13edfa17" }, { "bytes": 7953, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "70516a1374d183a9b142db08a19335232a7099f5a69f1798e43dc52a87e42958" }, { "bytes": 7611, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "6fa416f99c3a54bb75e356eab33f6fbdbfe38f05f4739c33ef9f2cb76b7c0ee5" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089501/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089501", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-78d4-b919-39830bcf4cec" } 4wKueli0NcTXNNXqjVd53YrlC/e5SDfXgpCXTiU1WWE2w8hSLxCg3dQYC+C15qwFBiu5mBsvpQd1RPuOvN0iDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 4wKueli0NcTXNNXqjVd53YrlC/e5SDfXgpCXTiU1WWE2w8hSLxCg3dQYC+C15qwFBiu5mBsvpQd1RPuOvN0iDQ== {"files":[{"bytes":19160,"name":"index.html","sha256":"a907233f5f256c21bff320ba909231addaadc42f9965470883cf3ca88a87160f"},{"bytes":8654,"name":"publication.md","sha256":"c34ec7145a1730b90a5f9089933d8e78ae7beb9921e794b1c748c9e84df0ee75"},{"bytes":8306,"name":"publication.txt","sha256":"c1b296e01fe9155046652921ca14acf0f754ec68aab8bc6c34c474973bd0f068"},{"bytes":2875,"name":"manifest.json","sha256":"f17db1a2dc153051f2eda070bc926a35254b97d6a7144267849a29d650551990"},{"bytes":89,"name":"manifest.sig","sha256":"1d630517a460b92054290a5547454af9408172f9fdd3059b27d20d91c801d5dd"},{"bytes":227,"name":"manifest.sig.txt","sha256":"a666312bab3e3a08e89e3bc8647845b0869658d2b7ead72ef26daef7f116811d"}],"publication_id":"OT-2026-000089502"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089502
OpenTechnical

OT-2026-000089502

Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c1b296e01fe9155046652921ca14acf0f754ec68aab8bc6c34c474973bd0f068

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089502, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089502.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089502" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089502" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089502 Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089502 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089502 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089502 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089502", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19160, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a907233f5f256c21bff320ba909231addaadc42f9965470883cf3ca88a87160f" }, { "bytes": 8654, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c34ec7145a1730b90a5f9089933d8e78ae7beb9921e794b1c748c9e84df0ee75" }, { "bytes": 8306, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c1b296e01fe9155046652921ca14acf0f754ec68aab8bc6c34c474973bd0f068" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089502/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089502", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7782-84f5-67dc76e6b5a8" } 3yntv13WBRyDbfIMttFkqwe/xeIWluGs6nr012N+PMLSc6uGIdtKAhWlIIDtztDedjcE/0LeWjGB7cs5+/lIBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 3yntv13WBRyDbfIMttFkqwe/xeIWluGs6nr012N+PMLSc6uGIdtKAhWlIIDtztDedjcE/0LeWjGB7cs5+/lIBw== {"files":[{"bytes":18907,"name":"index.html","sha256":"fc21bd3f27096c52ac348d848c910d5ad244cb4d24df19942d627292eb92b623"},{"bytes":8444,"name":"publication.md","sha256":"01c61c2939c0d8ae4904fd61c331188e5bd17eca1b012264a150c44dc5a026a1"},{"bytes":8096,"name":"publication.txt","sha256":"7bab3c9c4989d0071e62cc7e30813f02538d7aebd7422c4adea9fa0cd94c5a96"},{"bytes":2875,"name":"manifest.json","sha256":"3100ccd54be488df3f8abc5e1a8c52b71f3e25c2ef848fbbab327abb897887a1"},{"bytes":89,"name":"manifest.sig","sha256":"27b404ad0f8e66355d800d9b550a8cfa9cca2eb9fe8809b2ac5ced50924a98b3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"d18bb36defd2dbf682cb8a5c43e01b5ec8aa4ed548579cdf07fdf0f832fb5731"}],"publication_id":"OT-2026-000089503"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089503
OpenTechnical

OT-2026-000089503

Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
7bab3c9c4989d0071e62cc7e30813f02538d7aebd7422c4adea9fa0cd94c5a96

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089503, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089503.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089503" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089503" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089503 Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089503 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089503 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089503 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089503", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18907, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "fc21bd3f27096c52ac348d848c910d5ad244cb4d24df19942d627292eb92b623" }, { "bytes": 8444, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "01c61c2939c0d8ae4904fd61c331188e5bd17eca1b012264a150c44dc5a026a1" }, { "bytes": 8096, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "7bab3c9c4989d0071e62cc7e30813f02538d7aebd7422c4adea9fa0cd94c5a96" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089503/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089503", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7248-b9bb-c365305684e7" } DyBaFbST7rKvhUYUstHTCy/DHSukJ+MZcZefpj6SkRejmXQF5rUtGymZpW24X9YvkmScgaBQdhW8rq67XoH+Aw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: DyBaFbST7rKvhUYUstHTCy/DHSukJ+MZcZefpj6SkRejmXQF5rUtGymZpW24X9YvkmScgaBQdhW8rq67XoH+Aw== {"files":[{"bytes":18346,"name":"index.html","sha256":"44b7fa66a4f0beb8ce4cabef6f4b8701ef8425e7e215c694e4df72754b70f1d3"},{"bytes":7954,"name":"publication.md","sha256":"c3ab69857799d6e3d4a52dfd54c8265522af3ccb0c0d9a0ae1248f0c90d745f3"},{"bytes":7612,"name":"publication.txt","sha256":"94297b6d7656d96308517797f91dc25e9b60a15f88f076434ec83cb8a45513fa"},{"bytes":2863,"name":"manifest.json","sha256":"9c4a666a5cb006080dfa76ef38d704f51df6ccb3a2723f7ff176a2d6197bf486"},{"bytes":89,"name":"manifest.sig","sha256":"45f566da267fde052d2e9de5721a9c075aea08297ee0e9936ff82f92d00a2683"},{"bytes":227,"name":"manifest.sig.txt","sha256":"35b5abcc976377b0a3635133419425fc436711a9d8f3b243895a6ce2c4785e13"}],"publication_id":"OT-2026-000089504"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089504
OpenTechnical

OT-2026-000089504

Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
94297b6d7656d96308517797f91dc25e9b60a15f88f076434ec83cb8a45513fa

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089504, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089504.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089504" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089504" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089504 Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089504 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089504 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089504 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089504", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18346, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "44b7fa66a4f0beb8ce4cabef6f4b8701ef8425e7e215c694e4df72754b70f1d3" }, { "bytes": 7954, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c3ab69857799d6e3d4a52dfd54c8265522af3ccb0c0d9a0ae1248f0c90d745f3" }, { "bytes": 7612, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "94297b6d7656d96308517797f91dc25e9b60a15f88f076434ec83cb8a45513fa" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089504/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089504", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7c41-80e6-1dcb14bb6e6f" } +ryHzXybl4R+1iy6Es10Ss+OSEhDYK8MAzM8zg0oMoPfa31e0rve+2OCSSmDudTLuq2wbuz2i6xg35aDbM6HBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: +ryHzXybl4R+1iy6Es10Ss+OSEhDYK8MAzM8zg0oMoPfa31e0rve+2OCSSmDudTLuq2wbuz2i6xg35aDbM6HBg== {"files":[{"bytes":19161,"name":"index.html","sha256":"b4f4869fc33b38baf63e8531261b90a36b8c5682e12ebf8d5535567614c5e3bc"},{"bytes":8655,"name":"publication.md","sha256":"7df4ed1433d3b1d4c93a99472c1559f03f9b0f1eb4e3cfedbb632c84966616e1"},{"bytes":8307,"name":"publication.txt","sha256":"d3d5cfdf5f85a423ff465c27f1a7bd004f0f0c8a2e21f1bea2c3da802eee9c1f"},{"bytes":2875,"name":"manifest.json","sha256":"ec2cd8dae5ed961d3d46ce24bf78417f39d6903829cffeba26e3fe8817e4e306"},{"bytes":89,"name":"manifest.sig","sha256":"891a82a824c7a92a5769da91126fb8f551addc1ff920fe786ef07810cc393eed"},{"bytes":227,"name":"manifest.sig.txt","sha256":"62c4d80fd596d203b5927295411b064f05088d17fdd16c4a0610af4d0625460b"}],"publication_id":"OT-2026-000089505"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089505
OpenTechnical

OT-2026-000089505

Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
d3d5cfdf5f85a423ff465c27f1a7bd004f0f0c8a2e21f1bea2c3da802eee9c1f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089505, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089505.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089505" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089505" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089505 Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089505 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089505 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089505 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089505", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19161, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b4f4869fc33b38baf63e8531261b90a36b8c5682e12ebf8d5535567614c5e3bc" }, { "bytes": 8655, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "7df4ed1433d3b1d4c93a99472c1559f03f9b0f1eb4e3cfedbb632c84966616e1" }, { "bytes": 8307, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "d3d5cfdf5f85a423ff465c27f1a7bd004f0f0c8a2e21f1bea2c3da802eee9c1f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089505/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089505", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7746-8ac9-dad96a0eb12e" } i2qjtK5GOdWIEWGZ4xaQ9dnfhSNGyRTP03HEF/aKE3UQdo0N/lG5k4FjOY8duL8/lWuGOa9lc+qG+8simdBcDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: i2qjtK5GOdWIEWGZ4xaQ9dnfhSNGyRTP03HEF/aKE3UQdo0N/lG5k4FjOY8duL8/lWuGOa9lc+qG+8simdBcDQ== {"files":[{"bytes":18908,"name":"index.html","sha256":"d359484ad4c263d557f296669607cccf8b54fe659f3154f6f33d1b0d34861f96"},{"bytes":8445,"name":"publication.md","sha256":"2038a13a862ce4b4e17ddb399a69b4c15081872774c8efd5e7125934bf32706e"},{"bytes":8097,"name":"publication.txt","sha256":"53f99ea8b3b0a68f97adbe4196b2f07988a86013645c34d6d4aa43567a180a01"},{"bytes":2875,"name":"manifest.json","sha256":"11e553d7cfbdda111962a6a23000288e6eb963af6cd3a04414e21140bd6c60b0"},{"bytes":89,"name":"manifest.sig","sha256":"1d1eac20d362fdf5617ea1e4542f13be3e14588d0a532171795045c28f0d3759"},{"bytes":227,"name":"manifest.sig.txt","sha256":"6da414a3e9a742efbdc0dff8faa5a924ef85250dd56d10af401f1087ba0fa383"}],"publication_id":"OT-2026-000089506"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089506
OpenTechnical

OT-2026-000089506

Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
53f99ea8b3b0a68f97adbe4196b2f07988a86013645c34d6d4aa43567a180a01

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089506, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089506.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089506" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089506" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089506 Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089506 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089506 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089506 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089506", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18908, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d359484ad4c263d557f296669607cccf8b54fe659f3154f6f33d1b0d34861f96" }, { "bytes": 8445, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "2038a13a862ce4b4e17ddb399a69b4c15081872774c8efd5e7125934bf32706e" }, { "bytes": 8097, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "53f99ea8b3b0a68f97adbe4196b2f07988a86013645c34d6d4aa43567a180a01" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089506/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089506", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7692-b626-823c1642b3eb" } mTqDSdOhwuGKQemkZGak4osi6vnRt2tGus5YfDEZNKAggrTb67+Rz3czP/uM9WJnEhKOpYzZKpmfoLZkBc9rDQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: mTqDSdOhwuGKQemkZGak4osi6vnRt2tGus5YfDEZNKAggrTb67+Rz3czP/uM9WJnEhKOpYzZKpmfoLZkBc9rDQ== {"files":[{"bytes":18350,"name":"index.html","sha256":"8d38cbb1756e20d581e1c965c2ca2d0b7aee0b8de90740594540f19b4eafd467"},{"bytes":7958,"name":"publication.md","sha256":"0a03706483927f6863c6f03a597cc9ef438997d8e15a4eb7d5c2ca855fd84ef9"},{"bytes":7616,"name":"publication.txt","sha256":"4d800c2bc419b27bd36ce614380615aa3fc84242389a2eaa221455c7162495c2"},{"bytes":2863,"name":"manifest.json","sha256":"200cf18d76c0bbc2f89f9983a8645f7bddbf8cf869484575b9c7f78427c7f760"},{"bytes":89,"name":"manifest.sig","sha256":"1378e50973fc57de2dbb3c7e14b8279421caff834a9e1fb7e540b6168804ae07"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7cf516dc3f1e35606af3eb79d79ad1bcf3d7e8a42643cc4fd2b966f8599d0813"}],"publication_id":"OT-2026-000089507"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089507
OpenTechnical

OT-2026-000089507

Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
4d800c2bc419b27bd36ce614380615aa3fc84242389a2eaa221455c7162495c2

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089507, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089507.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089507" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089507" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089507 Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089507 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089507 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089507 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089507", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18350, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8d38cbb1756e20d581e1c965c2ca2d0b7aee0b8de90740594540f19b4eafd467" }, { "bytes": 7958, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0a03706483927f6863c6f03a597cc9ef438997d8e15a4eb7d5c2ca855fd84ef9" }, { "bytes": 7616, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4d800c2bc419b27bd36ce614380615aa3fc84242389a2eaa221455c7162495c2" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089507/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089507", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7ca2-93a5-c3f4e7d0b4b9" } WeDSUrBhFarIsSJ+qgJV4hw/ZL1K4a9ewO8e2VVOaCg4f+XFA6LdQANGZ3N+YuzdDoIFcEmTkYiMj68gh3hpBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: WeDSUrBhFarIsSJ+qgJV4hw/ZL1K4a9ewO8e2VVOaCg4f+XFA6LdQANGZ3N+YuzdDoIFcEmTkYiMj68gh3hpBw== {"files":[{"bytes":19165,"name":"index.html","sha256":"88c9ecd091de3c711b090178db53253457f40152de303110553c564870e488cf"},{"bytes":8659,"name":"publication.md","sha256":"64c1d3d9c45d315fff23e94f9c53faa319391f55dc490e6df590e371a422c89a"},{"bytes":8311,"name":"publication.txt","sha256":"111bf95b069e097fe0594ef77b564d62a28f1a443c3928f92e3c98f1980c823d"},{"bytes":2875,"name":"manifest.json","sha256":"eb0df9141c8e6bf53baab79533d55a34950eabe909ddb6c13720e8af21876797"},{"bytes":89,"name":"manifest.sig","sha256":"6947a4479506da20d6e7f5eefa4b1d7cff3a7e7c3b1124a174a60c8515ff28e0"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b8df64f03af09115c64b730f805ee40bcdb23628d3c403b5bdfb16e995a48c03"}],"publication_id":"OT-2026-000089508"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089508
OpenTechnical

OT-2026-000089508

Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
111bf95b069e097fe0594ef77b564d62a28f1a443c3928f92e3c98f1980c823d

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089508, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089508.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089508" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089508" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089508 Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089508 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089508 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089508 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089508", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19165, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "88c9ecd091de3c711b090178db53253457f40152de303110553c564870e488cf" }, { "bytes": 8659, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "64c1d3d9c45d315fff23e94f9c53faa319391f55dc490e6df590e371a422c89a" }, { "bytes": 8311, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "111bf95b069e097fe0594ef77b564d62a28f1a443c3928f92e3c98f1980c823d" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089508/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089508", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-70e1-92d5-33ff8a670795" } wblvJGj4wOstxYP3SdAfgQAwSNpyWl+aePkw1eZa34CRQcsL3IOOqHfzs+8XdAfMCq3KjiqA29vDb9FUhYyTDA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: wblvJGj4wOstxYP3SdAfgQAwSNpyWl+aePkw1eZa34CRQcsL3IOOqHfzs+8XdAfMCq3KjiqA29vDb9FUhYyTDA== {"files":[{"bytes":18912,"name":"index.html","sha256":"d7968900a926b6a561e7d0ab5a8241f0bda6df89be70a6c615f6b1a940e165ac"},{"bytes":8449,"name":"publication.md","sha256":"57c90ffaa666aae63889ca866bc35610cb4e7176a644f30e029ac3b7f4e16349"},{"bytes":8101,"name":"publication.txt","sha256":"461cf28c7b6fc68d9a3201ebde0fdffe023de5c5ab9a65e1f5e1459579ff6d42"},{"bytes":2875,"name":"manifest.json","sha256":"23acb11a23523966bd4edc0691d213983504ba1d2d175dd8414b82e39962b6dc"},{"bytes":89,"name":"manifest.sig","sha256":"210b69165c4be721528080415684fe86115872a5f935e56c414d151322e653b5"},{"bytes":227,"name":"manifest.sig.txt","sha256":"28f1bf66bc20df24d586c34238f885e6292e547481de1160f43454c0050e5e3d"}],"publication_id":"OT-2026-000089509"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089509
OpenTechnical

OT-2026-000089509

Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
461cf28c7b6fc68d9a3201ebde0fdffe023de5c5ab9a65e1f5e1459579ff6d42

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089509, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089509.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089509" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089509" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089509 Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089509 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089509 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089509 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089509", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18912, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "d7968900a926b6a561e7d0ab5a8241f0bda6df89be70a6c615f6b1a940e165ac" }, { "bytes": 8449, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "57c90ffaa666aae63889ca866bc35610cb4e7176a644f30e029ac3b7f4e16349" }, { "bytes": 8101, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "461cf28c7b6fc68d9a3201ebde0fdffe023de5c5ab9a65e1f5e1459579ff6d42" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089509/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089509", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7070-9b62-54c7e1c4b448" } sM3Y22zBm6zcjHSSx8CaFYGhyP+bFlfKLjci/Wr4y9lBzaWH69pF+M8VpLxMUxqJQCNWzBtoeQtJESwqr1KyBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: sM3Y22zBm6zcjHSSx8CaFYGhyP+bFlfKLjci/Wr4y9lBzaWH69pF+M8VpLxMUxqJQCNWzBtoeQtJESwqr1KyBQ== {"files":[{"bytes":18523,"name":"index.html","sha256":"2066ea0d3aa303b06ca1a015120f966d284ee89b35e26cb81464190f7211f070"},{"bytes":8103,"name":"publication.md","sha256":"81004fa09082b9c8c3f94f58adff9da8d6e97685cf616d4aaa27c0d6395d99f5"},{"bytes":7773,"name":"publication.txt","sha256":"29eaa1f3f0c864f1b3ed63eab7221a7a1eea3dbfe4d5d50a7e58fa81498f4bfc"},{"bytes":2838,"name":"manifest.json","sha256":"d4102f02a7e11939450b96b225416273440c8b1b0afb7c62fc0aceacc5dab7ae"},{"bytes":89,"name":"manifest.sig","sha256":"12a4b740ad75ca01c4c55ae088087af2f94071a9e9d917b26ef88ab4fe2f7a3d"},{"bytes":227,"name":"manifest.sig.txt","sha256":"721deeb1ace244672175f6caf79d541e249e85b9920879243fd41c4c269b5885"}],"publication_id":"OT-2026-000089510"} Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089510
OpenTechnical

OT-2026-000089510

Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
29eaa1f3f0c864f1b3ed63eab7221a7a1eea3dbfe4d5d50a7e58fa81498f4bfc

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089510, “Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089510.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089510" title: "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089510" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089510 Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089510 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089510 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089510 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089510", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1131 }, "figures": [], "files": [ { "bytes": 18523, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "2066ea0d3aa303b06ca1a015120f966d284ee89b35e26cb81464190f7211f070" }, { "bytes": 8103, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "81004fa09082b9c8c3f94f58adff9da8d6e97685cf616d4aaa27c0d6395d99f5" }, { "bytes": 7773, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "29eaa1f3f0c864f1b3ed63eab7221a7a1eea3dbfe4d5d50a7e58fa81498f4bfc" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089510/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089510", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7908-9e8f-082b7b63116f" } TrF47OuQ7Pl4ryXGTAbPhsx/9veytJeQ9BjFzAd9QsumMyg2ULIHQRGiZRoVH7aRmR6IfQYIwrgm9dEKa3rgBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: TrF47OuQ7Pl4ryXGTAbPhsx/9veytJeQ9BjFzAd9QsumMyg2ULIHQRGiZRoVH7aRmR6IfQYIwrgm9dEKa3rgBw== {"files":[{"bytes":19338,"name":"index.html","sha256":"f6df208c0b044a4942492e6fd9492fcabbb7e834e6c39966aab4392b9f70aa90"},{"bytes":8804,"name":"publication.md","sha256":"216ce7ab150f5aa8c97f150dd614c9f8a7ec91805dec7d5bceef77cc2103a1a3"},{"bytes":8468,"name":"publication.txt","sha256":"c93e1a20069fb503f0198d5b49c199bafd31a0e19633f301b3b8bad11feba508"},{"bytes":2850,"name":"manifest.json","sha256":"9e0d6433282352829a71ac0d88bb70dff1732dcde61271a8178af1f994f9a893"},{"bytes":89,"name":"manifest.sig","sha256":"f57bc03e657796ee56f629d67f1cb0fbc3edc944a4f4ed1c9024ccebd4562af9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1a0e7d57edefa74bd47fc60bbf61173d25175e7338f4a8f0ef1bd3f14077b979"}],"publication_id":"OT-2026-000089511"} Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089511
OpenTechnical

OT-2026-000089511

Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c93e1a20069fb503f0198d5b49c199bafd31a0e19633f301b3b8bad11feba508

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089511, “Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089511.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089511" title: "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089511" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089511 Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089511 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089511 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089511 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089511", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1237 }, "figures": [], "files": [ { "bytes": 19338, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f6df208c0b044a4942492e6fd9492fcabbb7e834e6c39966aab4392b9f70aa90" }, { "bytes": 8804, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "216ce7ab150f5aa8c97f150dd614c9f8a7ec91805dec7d5bceef77cc2103a1a3" }, { "bytes": 8468, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c93e1a20069fb503f0198d5b49c199bafd31a0e19633f301b3b8bad11feba508" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089511/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089511", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7e63-84b8-3ffe3f803de2" } ml+fi/2m3x99yljsUFcJRhIBGpUgRKL1g85+vjtmEXCZodhg4xjbRQq2F9UKSjDHdi537zJYTAG8nVkOtpSVBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ml+fi/2m3x99yljsUFcJRhIBGpUgRKL1g85+vjtmEXCZodhg4xjbRQq2F9UKSjDHdi537zJYTAG8nVkOtpSVBw== {"files":[{"bytes":19085,"name":"index.html","sha256":"fbc51c6084b13e3156e1513d9777facb195b3678700254b60a393a12638364f7"},{"bytes":8594,"name":"publication.md","sha256":"1b7d87bae9335670bfcf54fe9c48d0cfb3f0aa39de1b1ec3a3d19d47332cc352"},{"bytes":8258,"name":"publication.txt","sha256":"f5a25e63015282f423c0321f5295b279a71d4d613a7ce0182382d789a47b3c12"},{"bytes":2850,"name":"manifest.json","sha256":"d472d8fe36139154b8a6b9888505ec570260fe25170f36a5570400556aa49261"},{"bytes":89,"name":"manifest.sig","sha256":"8067d5addd0b793bcbd615b8bee4cddf46253392ca74de334a3dec84e4f43fb9"},{"bytes":227,"name":"manifest.sig.txt","sha256":"ae4ae11499790298f389575408d874df513dda64856da75c2203aee2f890bc0e"}],"publication_id":"OT-2026-000089512"} Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089512
OpenTechnical

OT-2026-000089512

Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
f5a25e63015282f423c0321f5295b279a71d4d613a7ce0182382d789a47b3c12

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089512, “Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089512.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089512" title: "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089512" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089512 Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089512 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089512 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089512 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089512", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1202 }, "figures": [], "files": [ { "bytes": 19085, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "fbc51c6084b13e3156e1513d9777facb195b3678700254b60a393a12638364f7" }, { "bytes": 8594, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "1b7d87bae9335670bfcf54fe9c48d0cfb3f0aa39de1b1ec3a3d19d47332cc352" }, { "bytes": 8258, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "f5a25e63015282f423c0321f5295b279a71d4d613a7ce0182382d789a47b3c12" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089512/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089512", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7b8e-a004-76dcd056cbd1" } xpFmilJ0Ou837d8xCJVXHDsChmrPmI5B3Oh2tnD/BNTMZ6JFm9sj9vRMLVERwiq//fHJ7JxV/tmwKSaAPEU+BA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: xpFmilJ0Ou837d8xCJVXHDsChmrPmI5B3Oh2tnD/BNTMZ6JFm9sj9vRMLVERwiq//fHJ7JxV/tmwKSaAPEU+BA== {"files":[{"bytes":18469,"name":"index.html","sha256":"26033fec94fb67c0cd053fe9219c206cf4f004a139cb394e721a09ba88127545"},{"bytes":8049,"name":"publication.md","sha256":"fb66d1885103d34ea9c69bb8ff934ebd3118a767508151142d3c52d0922b1454"},{"bytes":7719,"name":"publication.txt","sha256":"30badad38841f122ec1b9866781506616bd2685e924421667ccbbd1086ab366a"},{"bytes":2838,"name":"manifest.json","sha256":"a46c951c0600e5f4aaae150bfcd68cd5132d8e9686fb3a8cbc8cd7082294942b"},{"bytes":89,"name":"manifest.sig","sha256":"ab635e254d3522e9b8e8755f50ccb6958b30ae0b6a577eb3c9d701e6db0926bc"},{"bytes":227,"name":"manifest.sig.txt","sha256":"fc3a01fa60e7f99923d6948e0dad7f2422025221cd0991c550a18c45cf222ef1"}],"publication_id":"OT-2026-000089513"} Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089513
OpenTechnical

OT-2026-000089513

Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
30badad38841f122ec1b9866781506616bd2685e924421667ccbbd1086ab366a

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089513, “Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089513.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089513" title: "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089513" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089513 Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089513 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089513 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089513 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089513", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1116 }, "figures": [], "files": [ { "bytes": 18469, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "26033fec94fb67c0cd053fe9219c206cf4f004a139cb394e721a09ba88127545" }, { "bytes": 8049, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "fb66d1885103d34ea9c69bb8ff934ebd3118a767508151142d3c52d0922b1454" }, { "bytes": 7719, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "30badad38841f122ec1b9866781506616bd2685e924421667ccbbd1086ab366a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089513/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089513", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-75fa-bc3d-df76a779869b" } OsvDRcMQN4kZbqo7ZRDR4AuPbcQTilfkAVBxtINhBrI0MlYLhVcgPB6LLMYtMHXy3erzCjejTo0rgmIWNlvbBQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: OsvDRcMQN4kZbqo7ZRDR4AuPbcQTilfkAVBxtINhBrI0MlYLhVcgPB6LLMYtMHXy3erzCjejTo0rgmIWNlvbBQ== {"files":[{"bytes":19284,"name":"index.html","sha256":"572986bf60e738da8ed28aa9c6966ce653ec5929576e1254b2f08d3bec077295"},{"bytes":8750,"name":"publication.md","sha256":"66a01e3964e3e5005bc0acc4c89d07ee6cc821444e8b635ec4dbf2be69ae65dc"},{"bytes":8414,"name":"publication.txt","sha256":"12bb28fabe50a375c98795842afeb2cf2035c15f0762710485438e7e48263075"},{"bytes":2850,"name":"manifest.json","sha256":"bac63b9c22a4386b894210551d9c8e0e061bfcd3644c3052f3224ac85e0568c6"},{"bytes":89,"name":"manifest.sig","sha256":"2951f3c7e5c8761f49cb7b3d292f97f21609439f21601f225cc6ff3dfebb90b1"},{"bytes":227,"name":"manifest.sig.txt","sha256":"bd37ff112c5d865a8b3c2bff37e9d3b33a2c8a73ea6aa70010bd205e2e1d4876"}],"publication_id":"OT-2026-000089514"} Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089514
OpenTechnical

OT-2026-000089514

Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
12bb28fabe50a375c98795842afeb2cf2035c15f0762710485438e7e48263075

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089514, “Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089514.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089514" title: "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089514" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089514 Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089514 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089514 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089514 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089514", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1222 }, "figures": [], "files": [ { "bytes": 19284, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "572986bf60e738da8ed28aa9c6966ce653ec5929576e1254b2f08d3bec077295" }, { "bytes": 8750, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "66a01e3964e3e5005bc0acc4c89d07ee6cc821444e8b635ec4dbf2be69ae65dc" }, { "bytes": 8414, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "12bb28fabe50a375c98795842afeb2cf2035c15f0762710485438e7e48263075" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089514/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089514", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7434-b246-1baf856fa6a2" } RFXjXJBkinAOfq7KIN9a9sluCRGe+YzzL8+nDE0L+7v6aCtB3KCPQmf/qY2eu9L0t4b3s9t53Spvq1AHOH5iAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: RFXjXJBkinAOfq7KIN9a9sluCRGe+YzzL8+nDE0L+7v6aCtB3KCPQmf/qY2eu9L0t4b3s9t53Spvq1AHOH5iAw== {"files":[{"bytes":19031,"name":"index.html","sha256":"1ec7dc9f50b173eb312c68c0a526e4dccf6e89030376d5e926f68d43b8889b15"},{"bytes":8540,"name":"publication.md","sha256":"a0e848afbfbef273ba261093399e01b62b4d88f68516a6bd0430b9e4c49b8361"},{"bytes":8204,"name":"publication.txt","sha256":"20917cddb48aeb92a050a2c98c180b0fda63d7cab5876f51276c94802df69008"},{"bytes":2850,"name":"manifest.json","sha256":"b1cfde6122d5cee5daea5af71d0b4b1641eadd0e993cf4874b69f7ea72f7bad4"},{"bytes":89,"name":"manifest.sig","sha256":"c483679b19b7622820a7cccb139180c0e06c9cb121155203dd45da4a35131974"},{"bytes":227,"name":"manifest.sig.txt","sha256":"01011ebf107e225808c9b0a36207d641b3f92309bf2b9a729b646501b27c9f15"}],"publication_id":"OT-2026-000089515"} Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089515
OpenTechnical

OT-2026-000089515

Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
20917cddb48aeb92a050a2c98c180b0fda63d7cab5876f51276c94802df69008

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece.

[0031]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089515, “Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089515.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089515" title: "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089515" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089515 Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089515 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of closed cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: closed cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The closed-cell foam does not pass air through its body; the face is evacuated through openings cut through the pad into the distribution chamber, and the foam around each opening forms the seal against the workpiece. [0031] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089515 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089515 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089515", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1187 }, "figures": [], "files": [ { "bytes": 19031, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "1ec7dc9f50b173eb312c68c0a526e4dccf6e89030376d5e926f68d43b8889b15" }, { "bytes": 8540, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a0e848afbfbef273ba261093399e01b62b4d88f68516a6bd0430b9e4c49b8361" }, { "bytes": 8204, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "20917cddb48aeb92a050a2c98c180b0fda63d7cab5876f51276c94802df69008" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089515/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089515", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-709c-8668-39689b4e2f37" } r1Efnucmk9liBI+SixY6fvIGMZ+8Q1hqcqDbkq4JnzLT/fLSOVqLRiPW05kufH9UOUKUQFt236GVasWOS+jPAw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: r1Efnucmk9liBI+SixY6fvIGMZ+8Q1hqcqDbkq4JnzLT/fLSOVqLRiPW05kufH9UOUKUQFt236GVasWOS+jPAw== {"files":[{"bytes":18239,"name":"index.html","sha256":"f7fb094c2cb766e29116408b2211fd9c8316dca4c2c4f5770c65231d69eef308"},{"bytes":7863,"name":"publication.md","sha256":"3b5783a730efaf02f6ad871f7e8e0a85fe8bec85422caf04dd138773f733e60c"},{"bytes":7529,"name":"publication.txt","sha256":"b8215a6213051165e3cc57ef6bcecb967f78cedea70b3a887d7ed6f04601be15"},{"bytes":2855,"name":"manifest.json","sha256":"9c43d64b1623a266d930da3f52c60f5a4956aece8efcfc18180e54b8ab254b92"},{"bytes":89,"name":"manifest.sig","sha256":"bc6f68b25a125658e3cdb0b395695c193ca7338a7d07f7222e572406aec76aa3"},{"bytes":227,"name":"manifest.sig.txt","sha256":"76bc51dd2378bff2cba9f8f4c79423f9caa755df54f88e62d33b0d764d85200a"}],"publication_id":"OT-2026-000089516"} Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089516
OpenTechnical

OT-2026-000089516

Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
b8215a6213051165e3cc57ef6bcecb967f78cedea70b3a887d7ed6f04601be15

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089516, “Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089516.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089516" title: "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089516" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089516 Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089516 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089516 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089516 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089516", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1079 }, "figures": [], "files": [ { "bytes": 18239, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "f7fb094c2cb766e29116408b2211fd9c8316dca4c2c4f5770c65231d69eef308" }, { "bytes": 7863, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "3b5783a730efaf02f6ad871f7e8e0a85fe8bec85422caf04dd138773f733e60c" }, { "bytes": 7529, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "b8215a6213051165e3cc57ef6bcecb967f78cedea70b3a887d7ed6f04601be15" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089516/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089516", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7d55-8a8a-9f8c93c712c3" } 1f9LDrX5HsyfjyxjoiJDlBv4ZiIXjdqvtR0CrmPIG6uh/zMFyPziQC8tItjDPpz3NTq+ZtK60wY6lxYVtLiYDw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 1f9LDrX5HsyfjyxjoiJDlBv4ZiIXjdqvtR0CrmPIG6uh/zMFyPziQC8tItjDPpz3NTq+ZtK60wY6lxYVtLiYDw== {"files":[{"bytes":19054,"name":"index.html","sha256":"316b135606db44c5dfaffa3cfd6bdaa9aedcb3fb2894fdd41043a1638a678c7d"},{"bytes":8564,"name":"publication.md","sha256":"ff02a97a0ee4d924125b4683fcc55f889c0f6fb39451d2eccb5eb7e990b900bc"},{"bytes":8224,"name":"publication.txt","sha256":"3b14e2dd250d004c089c87fdec5224114c78a5219bef1f695add293fbf628b18"},{"bytes":2867,"name":"manifest.json","sha256":"51e77fd5ce5070458dd31d7bd693daafc057e2e333c3ba4f2a6d4f00e08cf628"},{"bytes":89,"name":"manifest.sig","sha256":"0e739ecf6f12cb0eeee2b1ab13e9f5852eff39f8c10a67aaecf4c7ca71743283"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c5788a85c2d0ff6e8fa7c2e7def9c51d442c0d3546bc2fa56532d6da7badae55"}],"publication_id":"OT-2026-000089517"} Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089517
OpenTechnical

OT-2026-000089517

Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
3b14e2dd250d004c089c87fdec5224114c78a5219bef1f695add293fbf628b18

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089517, “Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089517.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089517" title: "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089517" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089517 Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089517 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089517 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089517 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089517", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1185 }, "figures": [], "files": [ { "bytes": 19054, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "316b135606db44c5dfaffa3cfd6bdaa9aedcb3fb2894fdd41043a1638a678c7d" }, { "bytes": 8564, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "ff02a97a0ee4d924125b4683fcc55f889c0f6fb39451d2eccb5eb7e990b900bc" }, { "bytes": 8224, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "3b14e2dd250d004c089c87fdec5224114c78a5219bef1f695add293fbf628b18" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089517/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089517", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-748e-9941-3d9637d2aab6" } z/S0GzSpZh7ymJavL816fHc2PR8ptJkzDBB5afZwK8qR+djgR5yu0KQroQKHHOk1FzUQHMyOLWKRZfesCuXcAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: z/S0GzSpZh7ymJavL816fHc2PR8ptJkzDBB5afZwK8qR+djgR5yu0KQroQKHHOk1FzUQHMyOLWKRZfesCuXcAA== {"files":[{"bytes":18801,"name":"index.html","sha256":"ec140d22ec3a6928e7ce20db2bae4b825572dd6446c0ac2228db4d588d57550d"},{"bytes":8354,"name":"publication.md","sha256":"0fe4b27cd931570a64d1d3a7a10be1e83f3f33be6b58220d4b0af0eac02ba940"},{"bytes":8014,"name":"publication.txt","sha256":"bc0d527a8d595a5e45d8c485f8d94508a62a275efce668d5a70f14535a22e213"},{"bytes":2867,"name":"manifest.json","sha256":"d2ced28128ca3457e035f173886844428f402b3f8e1664a09c1c22f974655616"},{"bytes":89,"name":"manifest.sig","sha256":"f6613f1da7eb098f49bbc24c549c30d30f920a2c2c4211b010d28436998eb3ee"},{"bytes":227,"name":"manifest.sig.txt","sha256":"286fbd3950e7be6bd40faf98695528cc89cc3c9c1da7d4a1399fb1cdd0e45645"}],"publication_id":"OT-2026-000089518"} Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089518
OpenTechnical

OT-2026-000089518

Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
bc0d527a8d595a5e45d8c485f8d94508a62a275efce668d5a70f14535a22e213

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089518, “Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089518.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089518" title: "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089518" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089518 Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089518 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the flat form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: flat (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089518 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089518 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089518", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1150 }, "figures": [], "files": [ { "bytes": 18801, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "ec140d22ec3a6928e7ce20db2bae4b825572dd6446c0ac2228db4d588d57550d" }, { "bytes": 8354, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0fe4b27cd931570a64d1d3a7a10be1e83f3f33be6b58220d4b0af0eac02ba940" }, { "bytes": 8014, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "bc0d527a8d595a5e45d8c485f8d94508a62a275efce668d5a70f14535a22e213" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089518/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089518", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7307-9ace-31429a3a9616" } oruW+XebX3DLTsqDYOcf1MPe4XLtgjcmYDan4QXBHVoGArPH1kWbXe2rbuInDZxewy5aKK+gxB+s8DheJ6N1Cw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: oruW+XebX3DLTsqDYOcf1MPe4XLtgjcmYDan4QXBHVoGArPH1kWbXe2rbuInDZxewy5aKK+gxB+s8DheJ6N1Cw== {"files":[{"bytes":18239,"name":"index.html","sha256":"a7ffbcd4d3bac1e4121018b7a3f96e52567325715d78bd12484d2f028cd9f7cc"},{"bytes":7863,"name":"publication.md","sha256":"a1b2b47e7c7e715a749014b7b89be38ddeb13be48519c5d09381759310651683"},{"bytes":7529,"name":"publication.txt","sha256":"e14822741936da2c686b6dd284cf2f3ee9f9869af11a54dbac88677e319d4bff"},{"bytes":2855,"name":"manifest.json","sha256":"c810dc137fbb2376aa013c4166d8e626a2f5298c4549499313df86cb3edcaed1"},{"bytes":89,"name":"manifest.sig","sha256":"aaa72ff516b0c5b33800a1ddea4b4b3c31a96c7b292c412ea40035ad6dc34e89"},{"bytes":227,"name":"manifest.sig.txt","sha256":"9a52f7bec1d636cb25fd0848157d73057833370bcf4d88d74f61184afac14984"}],"publication_id":"OT-2026-000089519"} Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089519
OpenTechnical

OT-2026-000089519

Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
e14822741936da2c686b6dd284cf2f3ee9f9869af11a54dbac88677e319d4bff

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089519, “Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089519.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089519" title: "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089519" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089519 Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089519 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves and clearing the face at release. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-10549431-B2, US-11427405-B1, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089519 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089519 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089519", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1079 }, "figures": [], "files": [ { "bytes": 18239, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a7ffbcd4d3bac1e4121018b7a3f96e52567325715d78bd12484d2f028cd9f7cc" }, { "bytes": 7863, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a1b2b47e7c7e715a749014b7b89be38ddeb13be48519c5d09381759310651683" }, { "bytes": 7529, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "e14822741936da2c686b6dd284cf2f3ee9f9869af11a54dbac88677e319d4bff" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089519/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089519", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7773-a364-0b147eafa938" } p8KanTMADLz4ppGaZvji/HCyHyyNOC+bAgPTavOfE1WA7uH8QLUU6P4SGiug1i+HmRoWV+A6Sc7LQZqZLGNjBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: p8KanTMADLz4ppGaZvji/HCyHyyNOC+bAgPTavOfE1WA7uH8QLUU6P4SGiug1i+HmRoWV+A6Sc7LQZqZLGNjBA== {"files":[{"bytes":19054,"name":"index.html","sha256":"5b74bc951f730ec0cdbd45e3e8e9275f4ec3f1e837be3664a69679677c98b894"},{"bytes":8564,"name":"publication.md","sha256":"0180f41dc01ae73b87fbf6c6a599ba9474f1337dab66fe77e57df3f1934e37eb"},{"bytes":8224,"name":"publication.txt","sha256":"a6386a9d11d7b2879d56f13b82192054df36848689774b18df0f3ca37a160a42"},{"bytes":2867,"name":"manifest.json","sha256":"5cad840892602bc2c71f323c54113a75eca9659afc60b8a02847e2eae21569b1"},{"bytes":89,"name":"manifest.sig","sha256":"21d6ac5fbd81a8618914167019557e7bf7a5764a22ebd95e20746b209640a32e"},{"bytes":227,"name":"manifest.sig.txt","sha256":"55d3ba93152b85268b03e3a3479a1e289264e4d2f31cc794c6add6665da5529d"}],"publication_id":"OT-2026-000089520"} Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089520
OpenTechnical

OT-2026-000089520

Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
a6386a9d11d7b2879d56f13b82192054df36848689774b18df0f3ca37a160a42

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089520, “Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089520.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089520" title: "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089520" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089520 Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089520 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089520 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089520 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089520", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1185 }, "figures": [], "files": [ { "bytes": 19054, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "5b74bc951f730ec0cdbd45e3e8e9275f4ec3f1e837be3664a69679677c98b894" }, { "bytes": 8564, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "0180f41dc01ae73b87fbf6c6a599ba9474f1337dab66fe77e57df3f1934e37eb" }, { "bytes": 8224, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "a6386a9d11d7b2879d56f13b82192054df36848689774b18df0f3ca37a160a42" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089520/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089520", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-78f9-bd70-a35d5d472ebb" } EfuaTnAFSh34VaUFIGnhvDH1rqWRseXzPZabniLOm8yNrV1sesT2fgxgP2/JKgHo6yOoCv2F2+RLjDkHXcAgCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: EfuaTnAFSh34VaUFIGnhvDH1rqWRseXzPZabniLOm8yNrV1sesT2fgxgP2/JKgHo6yOoCv2F2+RLjDkHXcAgCw== {"files":[{"bytes":18801,"name":"index.html","sha256":"b89252db2b299f85b1c094710512376f98430116717ac23e69083495b05c1b11"},{"bytes":8354,"name":"publication.md","sha256":"c9d3aaaaf7d4d94b0a6d4ed9c952a9c222a1b9205c7b81886dc36bdd53cceb31"},{"bytes":8014,"name":"publication.txt","sha256":"555b002b7d501beccad9a60a265c91f5cd80623f92f6e7fc4198dbbbf1dbae0a"},{"bytes":2867,"name":"manifest.json","sha256":"142cd268b54cfb1ead0731460d5177a410f29e32f25fbb003423f141b3e2933b"},{"bytes":89,"name":"manifest.sig","sha256":"e2cda38b7f00f8fcddbe412306d87e6b9edc37cc15acda6cda9a5b58c40c0a82"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1411e76fbc643bec38d25628a6a65260e756abd6bb739f4e1d2872fc13aa235d"}],"publication_id":"OT-2026-000089521"} Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089521
OpenTechnical

OT-2026-000089521

Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
555b002b7d501beccad9a60a265c91f5cd80623f92f6e7fc4198dbbbf1dbae0a

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The suction cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the suction cups reach the workpiece, the suction cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089521, “Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089521.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089521" title: "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089521" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "suction cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three suction cups.** Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089521 Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089521 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three suction cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three suction cups. Each suction cup presents a sealing lip to the workpiece and is evacuated through its own connection. The count of three follows from the arrangement: one gripping element per zone branch. The suction cups are of the oval form. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has one stage. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The suction cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each suction cup is connected to its own zone line, one suction cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); form of the suction cups: oval (sets the shape of the contact area and the behaviour of the lip on a curved workpiece); material of the suction cups: polyurethane (sets the friction at the lip and the tolerance of the lip to oil and heat); stages of the ejector: one (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are US-11427405-B1, US-11858125-B2, US-2016214812-A1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089521 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089521 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three suction cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the suction cups reach the workpiece, the suction cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089521", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1150 }, "figures": [], "files": [ { "bytes": 18801, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "b89252db2b299f85b1c094710512376f98430116717ac23e69083495b05c1b11" }, { "bytes": 8354, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c9d3aaaaf7d4d94b0a6d4ed9c952a9c222a1b9205c7b81886dc36bdd53cceb31" }, { "bytes": 8014, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "555b002b7d501beccad9a60a265c91f5cd80623f92f6e7fc4198dbbbf1dbae0a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089521/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "suction cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089521", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three cup vacuum gripper, three zone face, three outlet manifold, single stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7e39-896d-c7b7a49f2200" } CHgs1KCUDUyzShC54TKrzU8PH7g+8xFHZxWkHE0BQ84egjFdBa4N1f/a8axxQM+VIH+J/6oxMgR4ZcfZ9gLxBg== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: CHgs1KCUDUyzShC54TKrzU8PH7g+8xFHZxWkHE0BQ84egjFdBa4N1f/a8axxQM+VIH+J/6oxMgR4ZcfZ9gLxBg== {"files":[{"bytes":18334,"name":"index.html","sha256":"6a66983f3149d1879f1754ce7fc8fd6b03c1a9d5a7cc6ae7fa04456b2501d199"},{"bytes":7948,"name":"publication.md","sha256":"d084265bed11a99dcb9eb81b98ffa472ab5ea03992f8896c1c9214f6abe41ef8"},{"bytes":7609,"name":"publication.txt","sha256":"09cf47d28982062827a7f31248e2e891e34f6dffa13fac9aee3b10f9dc4b0df1"},{"bytes":2860,"name":"manifest.json","sha256":"544a1a768c601ae1cf71f6fbbad5401b60fcbc17c593daace633d955d8661ecf"},{"bytes":89,"name":"manifest.sig","sha256":"232623ff0c87d90192921350b9227ddbf5c8351beffc59974f6386ca819c80c4"},{"bytes":227,"name":"manifest.sig.txt","sha256":"984bd49e4a98d034513e47e3642caa89b6ade7814a2b9ec8085e3157ebbc2389"}],"publication_id":"OT-2026-000089522"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089522
OpenTechnical

OT-2026-000089522

Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
09cf47d28982062827a7f31248e2e891e34f6dffa13fac9aee3b10f9dc4b0df1

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089522, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089522.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089522" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089522" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089522 Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089522 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089522 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089522 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089522", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18334, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6a66983f3149d1879f1754ce7fc8fd6b03c1a9d5a7cc6ae7fa04456b2501d199" }, { "bytes": 7948, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "d084265bed11a99dcb9eb81b98ffa472ab5ea03992f8896c1c9214f6abe41ef8" }, { "bytes": 7609, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "09cf47d28982062827a7f31248e2e891e34f6dffa13fac9aee3b10f9dc4b0df1" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089522/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089522", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7c1a-9c57-ae7db8c94b5b" } r4BUu/WTiFz6xI4JDOZJqk8UWYdsO7xwFXG8XXywE1opR8eYw8y/SxE/SL0nZvogRBQSaEyRxLPiJVkxXWxEBA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: r4BUu/WTiFz6xI4JDOZJqk8UWYdsO7xwFXG8XXywE1opR8eYw8y/SxE/SL0nZvogRBQSaEyRxLPiJVkxXWxEBA== {"files":[{"bytes":19149,"name":"index.html","sha256":"6645cb3f713afbc7c83c8a7a04681ba3995828494f1a8c9fe0e3d12bca236382"},{"bytes":8649,"name":"publication.md","sha256":"c7f664475b9800fa3472883bd717a806da4f19ecd1d973f0dbd2c1f4bf76b516"},{"bytes":8304,"name":"publication.txt","sha256":"005e3fd4f1ea305433e8579561f544dc99c855a95ef4cea3d6a81f40417509bc"},{"bytes":2872,"name":"manifest.json","sha256":"27ba96374baa739347c13b299892ef143b3908c73758555bb9c2b0f5db5fc49b"},{"bytes":89,"name":"manifest.sig","sha256":"f18021570c470df0c0e113b1310605fec6d8b5dfe0a8e19795277aca0a0a33fb"},{"bytes":227,"name":"manifest.sig.txt","sha256":"de0c60d78e580837cb00ffe20798fc6c2acb47e7eb56268449d9b5bcb2d4623f"}],"publication_id":"OT-2026-000089523"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089523
OpenTechnical

OT-2026-000089523

Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
005e3fd4f1ea305433e8579561f544dc99c855a95ef4cea3d6a81f40417509bc

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089523, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089523.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089523" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089523" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089523 Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089523 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089523 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089523 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089523", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19149, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "6645cb3f713afbc7c83c8a7a04681ba3995828494f1a8c9fe0e3d12bca236382" }, { "bytes": 8649, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "c7f664475b9800fa3472883bd717a806da4f19ecd1d973f0dbd2c1f4bf76b516" }, { "bytes": 8304, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "005e3fd4f1ea305433e8579561f544dc99c855a95ef4cea3d6a81f40417509bc" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089523/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089523", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-75f3-82d1-21901759c6a7" } OSpfPp/2QF0vJYE6j0RIib1bTUsy6t+JFTLTZ5yROnP6NjFF5ST29okPKBYkmTt+jb+cfDDBi94D+xs94qbACA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: OSpfPp/2QF0vJYE6j0RIib1bTUsy6t+JFTLTZ5yROnP6NjFF5ST29okPKBYkmTt+jb+cfDDBi94D+xs94qbACA== {"files":[{"bytes":18896,"name":"index.html","sha256":"24f8e2c78aa18a7d0f29049f1f6dd5ddfc1970ec95d56339656fa9c21297bc5b"},{"bytes":8439,"name":"publication.md","sha256":"5275f46e7f3f3d83eca5157ff09acc915b3008df5c03ce862b6a3ba16fbc36ae"},{"bytes":8094,"name":"publication.txt","sha256":"8aa797def7c6b7c4e65a8885f5d241e2074f705a836707c7a81f569eda12c04a"},{"bytes":2872,"name":"manifest.json","sha256":"8d4918f95261ddd7ab2092005a20751fbaee25b283474a6116f9f5c6b984afce"},{"bytes":89,"name":"manifest.sig","sha256":"4e694a51ceae259d15686dca4e19ca401da9a9edc7ac0d641bd6af27d5fc0cff"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7446a0005717e792e4a81062c31704ff44068fc10f8ed4ef193c740417c8b792"}],"publication_id":"OT-2026-000089524"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089524
OpenTechnical

OT-2026-000089524

Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
8aa797def7c6b7c4e65a8885f5d241e2074f705a836707c7a81f569eda12c04a

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089524, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089524.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089524" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089524" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089524 Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089524 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has one fold. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: one (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089524 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089524 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089524", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18896, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "24f8e2c78aa18a7d0f29049f1f6dd5ddfc1970ec95d56339656fa9c21297bc5b" }, { "bytes": 8439, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "5275f46e7f3f3d83eca5157ff09acc915b3008df5c03ce862b6a3ba16fbc36ae" }, { "bytes": 8094, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "8aa797def7c6b7c4e65a8885f5d241e2074f705a836707c7a81f569eda12c04a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089524/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089524", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-70b0-a209-9bf000e27744" } WcM9Y/j2vKh7Afh+ePSGtMPdqNTDRM2lW79Xzr7NT764U5OGzLYjwdM+vXu1CsGESH7tp2l43MZmVrWxKOyfCQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: WcM9Y/j2vKh7Afh+ePSGtMPdqNTDRM2lW79Xzr7NT764U5OGzLYjwdM+vXu1CsGESH7tp2l43MZmVrWxKOyfCQ== {"files":[{"bytes":18335,"name":"index.html","sha256":"a6ecb6eeb66ed9afd0b646cf4ee9d5c34733b63a3c3228cfe8596b9ca57563b0"},{"bytes":7949,"name":"publication.md","sha256":"a7146b3de71fef87f941618d651e4ae1c19749568487541521f47540b4cc155a"},{"bytes":7610,"name":"publication.txt","sha256":"53e96b6bcd3cbcef0a0b6f1bdb791127130805c014cf853b52e6d58c89a253ab"},{"bytes":2860,"name":"manifest.json","sha256":"fc4031827a407f773957e488c560d5972c720d67265d19ad4d04a810a693c08e"},{"bytes":89,"name":"manifest.sig","sha256":"bde26c462b12594cf0164fbe0f5ab1ff873e17044d6b71432f40c146130ed727"},{"bytes":227,"name":"manifest.sig.txt","sha256":"38e215603146d38a37bf426a531adeccf2f8113145e45a087b61aa757c0c7424"}],"publication_id":"OT-2026-000089525"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089525
OpenTechnical

OT-2026-000089525

Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
53e96b6bcd3cbcef0a0b6f1bdb791127130805c014cf853b52e6d58c89a253ab

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089525, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089525.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089525" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089525" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089525 Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089525 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089525 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089525 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089525", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18335, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "a6ecb6eeb66ed9afd0b646cf4ee9d5c34733b63a3c3228cfe8596b9ca57563b0" }, { "bytes": 7949, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "a7146b3de71fef87f941618d651e4ae1c19749568487541521f47540b4cc155a" }, { "bytes": 7610, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "53e96b6bcd3cbcef0a0b6f1bdb791127130805c014cf853b52e6d58c89a253ab" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089525/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089525", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7992-865d-16465fdf9973" } 6t3DUUPK+zoNlWy3CiHz2cwRxYTHn6+TVPiFY2ZD4JkDaLdOT+r3fTsLgveXmqst5L/W48I39M9jkg49EcN1AA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: 6t3DUUPK+zoNlWy3CiHz2cwRxYTHn6+TVPiFY2ZD4JkDaLdOT+r3fTsLgveXmqst5L/W48I39M9jkg49EcN1AA== {"files":[{"bytes":19150,"name":"index.html","sha256":"3be3521afde431688c3751b18bb23889e6f32653d261cd7e98d2ebadfcbf28a4"},{"bytes":8650,"name":"publication.md","sha256":"b8770292bd863f0a1828c507042ab4a57fe87c6136fd45d0d45fd6fe14a16f28"},{"bytes":8305,"name":"publication.txt","sha256":"c0749f7c2a73b624a83aebd03da0bf32a87e41959624251d06be673a9cb2ed9f"},{"bytes":2872,"name":"manifest.json","sha256":"6c58a9ec00a7d337c8bf04e02b2da8d70482075ccfa059e3e06fbbfa1cfaabaa"},{"bytes":89,"name":"manifest.sig","sha256":"5842ad66c2113c18c1d86804a979f4ca08963fb4ff21c324d13e7ed8fbdde0b7"},{"bytes":227,"name":"manifest.sig.txt","sha256":"33aa8744b529387b7ab1151e3778256bd3f560c5d3b9d5a5d32f66fa21d31b7a"}],"publication_id":"OT-2026-000089526"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089526
OpenTechnical

OT-2026-000089526

Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
c0749f7c2a73b624a83aebd03da0bf32a87e41959624251d06be673a9cb2ed9f

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089526, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089526.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089526" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089526" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089526 Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089526 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089526 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089526 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089526", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19150, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "3be3521afde431688c3751b18bb23889e6f32653d261cd7e98d2ebadfcbf28a4" }, { "bytes": 8650, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b8770292bd863f0a1828c507042ab4a57fe87c6136fd45d0d45fd6fe14a16f28" }, { "bytes": 8305, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "c0749f7c2a73b624a83aebd03da0bf32a87e41959624251d06be673a9cb2ed9f" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089526/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089526", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7a94-a076-7f1399c8b637" } bbBxjvchQFReViwNiwlYcZO01T4nBrApj+D0C1Q0Y1GJ9/XWAhqmAe2HxCsKBnDzcOcxpUfyYiynJJQ9GNI9Dw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: bbBxjvchQFReViwNiwlYcZO01T4nBrApj+D0C1Q0Y1GJ9/XWAhqmAe2HxCsKBnDzcOcxpUfyYiynJJQ9GNI9Dw== {"files":[{"bytes":18897,"name":"index.html","sha256":"73c570f1ed3437a80b0f40708640cab3fa1b12110f7760a76673e3f5f75e80b6"},{"bytes":8440,"name":"publication.md","sha256":"b297c0c9c0ced35c4f54af909ebe682c5a135dd11cf31af5298cd8fe6dbd7eb6"},{"bytes":8095,"name":"publication.txt","sha256":"4863e654ec744412ea8b9785a24dbff285c143602641b9840a1cd6a5872d8301"},{"bytes":2872,"name":"manifest.json","sha256":"4d54de5a74dc013947633ad8d8bf4177322c105ed9d20a3100e64b5d392465a9"},{"bytes":89,"name":"manifest.sig","sha256":"db4c43363e9e1d03e05e2788b81e951e74da4e4ce6fc4855c7d80028206a1e24"},{"bytes":227,"name":"manifest.sig.txt","sha256":"b9356d9aaf5b5b2fa32697d045d067766df476f44ee4482f14bdc7f74f01153d"}],"publication_id":"OT-2026-000089527"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089527
OpenTechnical

OT-2026-000089527

Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
4863e654ec744412ea8b9785a24dbff285c143602641b9840a1cd6a5872d8301

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089527, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089527.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089527" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089527" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089527 Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089527 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has two folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: two (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089527 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089527 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089527", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18897, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "73c570f1ed3437a80b0f40708640cab3fa1b12110f7760a76673e3f5f75e80b6" }, { "bytes": 8440, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "b297c0c9c0ced35c4f54af909ebe682c5a135dd11cf31af5298cd8fe6dbd7eb6" }, { "bytes": 8095, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4863e654ec744412ea8b9785a24dbff285c143602641b9840a1cd6a5872d8301" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089527/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089527", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7b83-9eb5-6a4634832274" } M8DXr2hgzP/tg2koCYtk35s7NVJO5/Zo6uSCsHwdqGdIrDFAeEYp6HuBtiCAmpuWPE1fjpfiqbcWpYjdbq/5Cw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: M8DXr2hgzP/tg2koCYtk35s7NVJO5/Zo6uSCsHwdqGdIrDFAeEYp6HuBtiCAmpuWPE1fjpfiqbcWpYjdbq/5Cw== {"files":[{"bytes":18339,"name":"index.html","sha256":"8bb021f1715b7ad5103e1a29545722d285d07e714f5dbbc8564d84a58054f05f"},{"bytes":7953,"name":"publication.md","sha256":"62545ca2834c56bd4a38cfd55803bdfeabb8ab0ba04835cf846e2b45a97411e0"},{"bytes":7614,"name":"publication.txt","sha256":"4c3edc0a2b721cd362e71144fef9c1aced07d37334891d6e60961ca1fb132b6a"},{"bytes":2860,"name":"manifest.json","sha256":"ed09d3c129cb28a00351d392fb76a431b906bcaa904802132ac630f8dbd8c960"},{"bytes":89,"name":"manifest.sig","sha256":"f30e04c0b105e44f95fb6ff382eb138d081b6abb298e2d67a8380fb3cfc1c256"},{"bytes":227,"name":"manifest.sig.txt","sha256":"1159b102cdcdeb72aa8a11954c97b2ac0a5f7638150959354bfb64cc0438d032"}],"publication_id":"OT-2026-000089528"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089528
OpenTechnical

OT-2026-000089528

Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
4c3edc0a2b721cd362e71144fef9c1aced07d37334891d6e60961ca1fb132b6a

Abstract

A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0031]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089528, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089528.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089528" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089528" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089528 Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089528 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and taking up height differences at the face. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0031] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089528 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089528 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089528", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 31, "words": 1091 }, "figures": [], "files": [ { "bytes": 18339, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8bb021f1715b7ad5103e1a29545722d285d07e714f5dbbc8564d84a58054f05f" }, { "bytes": 7953, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "62545ca2834c56bd4a38cfd55803bdfeabb8ab0ba04835cf846e2b45a97411e0" }, { "bytes": 7614, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "4c3edc0a2b721cd362e71144fef9c1aced07d37334891d6e60961ca1fb132b6a" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089528/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089528", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7a21-9d4a-4ee3557d500c" } l1YWX7YYV9djwsFoLlRjVtb+h88Namcwttety8bWrlmagdR2s5qZppSsgFcdazVrcoovEwU7PNAqrx+5s1G3DA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: l1YWX7YYV9djwsFoLlRjVtb+h88Namcwttety8bWrlmagdR2s5qZppSsgFcdazVrcoovEwU7PNAqrx+5s1G3DA== {"files":[{"bytes":19154,"name":"index.html","sha256":"8792cd8858f1072507a9a63edc14ff0191f538c063bf0a5e5c3bdaac1ce845f8"},{"bytes":8654,"name":"publication.md","sha256":"e19fa2cc5ea993e83823de85c1e40fccf0687bd2d31fb9af92eeefd1df73f934"},{"bytes":8309,"name":"publication.txt","sha256":"9a94e84e7fde7f330dd44e0653a4c733a5f30767d9c59344198f330e0ee606c1"},{"bytes":2872,"name":"manifest.json","sha256":"7cf99c5a5fba597a68def249811cab5545f8efeea3ea81c71ec0982e0bec8d5c"},{"bytes":89,"name":"manifest.sig","sha256":"26b3ea27d911f4d89661f850a3c8ac8b9242bb66b0c520dd0be95457247fc561"},{"bytes":227,"name":"manifest.sig.txt","sha256":"c3f081321e7059c9ce0fd41392d4dcc350d92b1bf045fdae5ec0e951c920ac1d"}],"publication_id":"OT-2026-000089529"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089529
OpenTechnical

OT-2026-000089529

Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
9a94e84e7fde7f330dd44e0653a4c733a5f30767d9c59344198f330e0ee606c1

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0032]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0033]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089529, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089529.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089529" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089529" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089529 Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089529 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0032] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0033] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089529 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089529 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089529", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 33, "words": 1197 }, "figures": [], "files": [ { "bytes": 19154, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "8792cd8858f1072507a9a63edc14ff0191f538c063bf0a5e5c3bdaac1ce845f8" }, { "bytes": 8654, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "e19fa2cc5ea993e83823de85c1e40fccf0687bd2d31fb9af92eeefd1df73f934" }, { "bytes": 8309, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "9a94e84e7fde7f330dd44e0653a4c733a5f30767d9c59344198f330e0ee606c1" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089529/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089529", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7fe1-8db8-bfed808d9f1f" } ORfYHWNFJKKGeIb2XJ+XVwzPlBU4J1Nwtvm2qLS6LoxgtgNMIZBIyYMdkekxBOqwRREcfk/Yl1gpEjFtpzhwCw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: ORfYHWNFJKKGeIb2XJ+XVwzPlBU4J1Nwtvm2qLS6LoxgtgNMIZBIyYMdkekxBOqwRREcfk/Yl1gpEjFtpzhwCw== {"files":[{"bytes":18901,"name":"index.html","sha256":"584d46dec29fc2a636791a0b219d53c5281b459db335c3826b81358d4e4d2eb4"},{"bytes":8444,"name":"publication.md","sha256":"16051002a34b3b0d7e1842e73343d7de65d941fc29082425df0bf6f2bc42f6b9"},{"bytes":8099,"name":"publication.txt","sha256":"fb8c4f3535051d889bb83265ebc588e2c93c3753fa97393e7f401907adfaf0ec"},{"bytes":2872,"name":"manifest.json","sha256":"4da94c60bcb741c483b39a904133eebfde370330d05e0a3bdff5a2e7d176844b"},{"bytes":89,"name":"manifest.sig","sha256":"f5aed7ae23bd57a1ef75313c24be5d79b2400cd11dc4f6450b9560d1be1528df"},{"bytes":227,"name":"manifest.sig.txt","sha256":"e99e5dce0f6bd3498470117a4d65cfe0f92762201608d8beeae1966243d08235"}],"publication_id":"OT-2026-000089530"} Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089530
OpenTechnical

OT-2026-000089530

Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
fb8c4f3535051d889bb83265ebc588e2c93c3753fa97393e7f401907adfaf0ec

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock.

[0003]Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The bellows cups are carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089530, “Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089530.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089530" title: "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089530" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "bellows cup" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] **Three bellows cups.** Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089530 Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089530 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: three bellows cups carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, taking up height differences at the face and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a mechanical lock. [0003] Three bellows cups. Each bellows cup is folded so that it shortens under vacuum and takes up a height difference between the face and the workpiece. The count of three follows from the arrangement: one gripping element per zone branch. Each bellows cup has three folds. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The bellows cups are carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each bellows cup is connected to its own zone line, one bellows cup per zone, and is evacuated through that line. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: locking of the tool-change interface: mechanical (sets what has to be present at the interface for the tool to stay attached); folds of the bellows cups: three (sets the travel taken up between the face and the workpiece, and the lateral stiffness of the cup under load); material of the bellows cups: plastic (sets the friction at the lip and the resistance of the folds to fatigue); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The lock is engaged by a manually operated lever on the interface; no supply crosses the interface for the lock, and tool exchange needs an operator at the tool. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4489564-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089530 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089530 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, three bellows cups, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the bellows cups reach the workpiece, the bellows cups are evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089530", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1162 }, "figures": [], "files": [ { "bytes": 18901, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "584d46dec29fc2a636791a0b219d53c5281b459db335c3826b81358d4e4d2eb4" }, { "bytes": 8444, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "16051002a34b3b0d7e1842e73343d7de65d941fc29082425df0bf6f2bc42f6b9" }, { "bytes": 8099, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fb8c4f3535051d889bb83265ebc588e2c93c3753fa97393e7f401907adfaf0ec" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089530/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "bellows cup", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089530", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Three bellows cup vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-7040-ac05-9f6d3f47d23d" } fNTJbY9oYn7I7V8i4oep8ezXajYwdsfEncGip/0aUSK9vsP0bbHyZnFCdRTjCYW99TaLNd89yCIAv5qGDzSGAA== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: fNTJbY9oYn7I7V8i4oep8ezXajYwdsfEncGip/0aUSK9vsP0bbHyZnFCdRTjCYW99TaLNd89yCIAv5qGDzSGAA== {"files":[{"bytes":18512,"name":"index.html","sha256":"82d5f81a8e3bd647c7ede9dfe5d382a6cb55c3b1ea26a4dd02bd6a3577599a78"},{"bytes":8098,"name":"publication.md","sha256":"59f168ae973d1370b0e8dd3ee41f8e5d8e0264d123834be89adf79ac2b995747"},{"bytes":7771,"name":"publication.txt","sha256":"fc1d47dbea7c1bc2ba3a0db5517e1066de236d6c7e714057930f5c3b1aea5a16"},{"bytes":2835,"name":"manifest.json","sha256":"eae0ab89be253a09b7ee43844c071c67acc0110d8f6b378d49acdae4de80f46e"},{"bytes":89,"name":"manifest.sig","sha256":"e58f0d5e92dfbea2805a733071bf718cc8322ec4f3cfa02f003d94f4d7cb8e98"},{"bytes":227,"name":"manifest.sig.txt","sha256":"7a0117278947b7f925c79f8430cb1ccd6fd3223a4f304ab92e523e79d528010e"}],"publication_id":"OT-2026-000089531"} Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down - OpenTechnical OT-2026-000089531
OpenTechnical

OT-2026-000089531

Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Vacuum Generation
Document SHA-256
fc1d47dbea7c1bc2ba3a0db5517e1066de236d6c7e714057930f5c3b1aea5a16

Abstract

A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the mounting flange.

[0010]The manifold is fixed to the tool side of the mounting flange.

[0011]The ejector is fixed to the tool side of the mounting flange.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the mounting flange is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0021]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0022]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0023]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0024]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0025]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0026]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0027]Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0028]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0029]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0030]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0031]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0032]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089531, “Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089531.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089531" title: "Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089531" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "industrial-motion-power-transmission/fluid-power/vacuum-generation" keywords: - "zoned vacuum tool" - "mounting flange" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down ## Abstract A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One mounting flange.** The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089531 Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089531 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a mounting flange, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release and holding a workpiece that a rigid lip cannot seal against. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One mounting flange. The mounting flange carries the whole assembly and presents the bolt pattern that meets the robot. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the mounting flange. [0010] The manifold is fixed to the tool side of the mounting flange. [0011] The ejector is fixed to the tool side of the mounting flange. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the mounting flange is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The blow-off valve is switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0021] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0022] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0023] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0024] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0025] - The workpiece is held until the blow-off valve has opened the circuit. [0026] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0027] Parameter values of this embodiment: material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0028] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0029] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0030] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0031] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0032] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-10549431-B2, US-11427405-B1, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089531 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089531 { "abstract": "A zoned vacuum gripping tool comprising one mounting flange, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089531", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "industrial-motion-power-transmission/fluid-power/vacuum-generation" ], "extent": { "figures": 0, "paragraphs": 32, "words": 1131 }, "figures": [], "files": [ { "bytes": 18512, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "82d5f81a8e3bd647c7ede9dfe5d382a6cb55c3b1ea26a4dd02bd6a3577599a78" }, { "bytes": 8098, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "59f168ae973d1370b0e8dd3ee41f8e5d8e0264d123834be89adf79ac2b995747" }, { "bytes": 7771, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "fc1d47dbea7c1bc2ba3a0db5517e1066de236d6c7e714057930f5c3b1aea5a16" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089531/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "mounting flange", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089531", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down", "uuid": "01a0ae9b-db02-7575-ba7f-1a8e1fd99dc1" } POmXmi3/gLMJLmQ9kmQHjnRyzABnVj2+WSoOcthxCPemPrukDME9OWDKHODfWD5lvASwTAkVq3ngsNq8FM7yBw== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: POmXmi3/gLMJLmQ9kmQHjnRyzABnVj2+WSoOcthxCPemPrukDME9OWDKHODfWD5lvASwTAkVq3ngsNq8FM7yBw== {"files":[{"bytes":19327,"name":"index.html","sha256":"bb9959fc28706fc27992b9308156bb13d926b11477e3e6ddd74d5413bd04eb34"},{"bytes":8799,"name":"publication.md","sha256":"16c02d52b72590f629a0242607424818be36b548c9bf0fc846b07c5bf85fd1e8"},{"bytes":8466,"name":"publication.txt","sha256":"088a47759e30dabce366ad01449a9bbbad4de9351542542540fbe81e7528ba68"},{"bytes":2847,"name":"manifest.json","sha256":"51d96a4f691582d6240301c3d4e8f1b94a1b11e8205b05f420895706592aa89b"},{"bytes":89,"name":"manifest.sig","sha256":"74e6940b661cf1aeea450a3146fb63aa18069c3403fa03916861a3e413eec98f"},{"bytes":227,"name":"manifest.sig.txt","sha256":"0922e61355df8c91a9a62caebf0e4cdf11cb7b1e26ae6a2efa3be9bf1e93c202"}],"publication_id":"OT-2026-000089532"} Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer - OpenTechnical OT-2026-000089532
OpenTechnical

OT-2026-000089532

Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer

Published
Permanent URL
Classification
Robotics & Automation › End Effectors › Vacuum Grippers
Also classified in
Vacuum Sensors, Valves and Manifolds, Tool Changers
Document SHA-256
088a47759e30dabce366ad01449a9bbbad4de9351542542540fbe81e7528ba68

Abstract

A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.

1. Purpose and arrangement

[0001]This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations.

2. Components, construction and connections

[0002]One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock.

[0003]One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam.

[0004]One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages.

[0005]One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets.

[0006]Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch.

[0007]One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold.

[0008]One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down.

[0009]The foam pad is carried on the tool side of the tool-change interface.

[0010]The manifold is fixed to the tool side of the tool-change interface.

[0011]The ejector is fixed to the tool side of the tool-change interface.

[0012]The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold.

[0013]Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only.

[0014]Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone.

[0015]The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet.

[0016]The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face.

[0017]The robot side of the tool-change interface is bolted to the robot flange.

[0018]The ejector is fed from the compressed air supply of the cell.

[0019]The blow-off valve is fed from the compressed air supply of the cell.

[0020]The locking piston of the tool-change interface is fed from the compressed air supply of the cell.

[0021]The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller.

3. Operating sequence and conditions

[0022]

  • When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector.

[0023]

  • When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor.

[0024]

  • The workpiece may not be lifted unless the pressure sensor signals a secure grip.

[0025]

  • Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface.

[0026]

  • The workpiece is held until the blow-off valve has opened the circuit.

[0027]The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly.

4. Parameters and operating assumptions

[0028]Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down).

[0029]The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here.

[0030]The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away.

[0031]The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area.

[0032]The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement.

[0033]Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference.

5. Provenance and status

[0034]This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination.

Publication information

Citation

OpenTechnical Publication OT-2026-000089532, “Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer,” published September 17, 2026 at 09:04:04 UTC, https://opentechnical.org/p/OT-2026-000089532.

To cite specific content, add the paragraph or figure numbers.

Terms

Published through OpenTechnical, which means it has been made publicly available here. It is not a statement that the design has been built, tested or independently validated. Content is available under the Creative Commons Attribution 4.0 International licence. See the publication policy.

--- publication_id: "OT-2026-000089532" title: "Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer" published_at: "2026-09-17T09:04:04.880043Z" canonical_url: "https://opentechnical.org/p/OT-2026-000089532" categories: - "robotics-automation/end-effectors/vacuum-grippers" - "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors" - "industrial-motion-power-transmission/fluid-power/valves-and-manifolds" - "robotics-automation/end-effectors/tool-changers" keywords: - "zoned vacuum tool" - "tool-change interface" - "foam pad" - "ejector" - "manifold" - "zone branch" - "pressure sensor" - "blow-off valve" - "blow off release" - "compressed air supply" --- # Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer ## Abstract A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. ## 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. ## 2. Components, construction and connections [0002] **One tool-change interface.** The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] **One foam pad.** The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] **One ejector.** The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] **One manifold.** The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] **Three zone branches.** Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] **One pressure sensor.** The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] **One blow-off valve.** The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. ## 3. Operating sequence and conditions - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. - The workpiece may not be lifted unless the pressure sensor signals a secure grip. - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. ## 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. ## 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. OPENTECHNICAL PUBLICATION OT-2026-000089532 Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer Published: 2026-09-17T09:04:04.880043Z Permanent URL: https://opentechnical.org/p/OT-2026-000089532 Categories: Robotics & Automation > End Effectors > Vacuum Grippers ------------------------------------------------------------------------ ABSTRACT A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed. 1. Purpose and arrangement [0001] This disclosure describes a zoned vacuum gripping tool: one foam pad carried on a tool-change interface, fed by an ejector. It is arranged for handling workpieces that do not cover the whole gripping face, verifying that the workpiece is held before the arm moves, clearing the face at release, holding a workpiece that a rigid lip cannot seal against and exchanging the tool without rewiring the cell. One concrete embodiment is described; every connection is stated with the medium it carries, and the operating sequence is given as conditions on named operations. 2. Components, construction and connections [0002] One tool-change interface. The tool-change interface splits the tool into a robot side and a tool side, so the tool can be exchanged without dismantling it. The tool-change interface has a pneumatic lock. [0003] One foam pad. The foam pad presents a compliant face to the workpiece; the holding force is spread over the contact area rather than concentrated at a lip. The pad is of open cell foam. [0004] One ejector. The ejector draws the circuit down by passing compressed air through a nozzle; it has no moving part at the tool and consumes air for as long as it runs. The ejector has two stages. [0005] One manifold. The manifold receives the vacuum at one inlet and distributes it to its outlets. The manifold has three outlets. [0006] Three zone branches. Each zone branch carries the vacuum of one zone of the face and no other. The count of three follows from the arrangement: one branch per zone. The distribution is divided into three zones, each fed by its own branch. [0007] One pressure sensor. The pressure sensor taps the line it is placed in and reports the vacuum level in that line. The pressure is measured at the manifold. [0008] One blow-off valve. The blow-off valve drives compressed air back through the circuit to the face, which clears the face instead of waiting for the circuit to refill. The blow-off is a sustained blast. The blow-off pulse is given before set-down. [0009] The foam pad is carried on the tool side of the tool-change interface. [0010] The manifold is fixed to the tool side of the tool-change interface. [0011] The ejector is fixed to the tool side of the tool-change interface. [0012] The manifold inlet is connected to the ejector outlet, which supplies every outlet of the manifold. [0013] Each of the three zone branches is taken from its own manifold outlet, so that the branch carries the vacuum of its own zone only. [0014] Each zone line opens into its own section of the distribution chamber behind the porous face of the foam pad, so that the pad is evacuated zone by zone. [0015] The pressure sensor is tapped into the manifold body and reads the pressure common to every outlet. [0016] The blow-off valve is connected to the circuit at the ejector outlet, so that compressed air can be driven back through the circuit to the face. [0017] The robot side of the tool-change interface is bolted to the robot flange. [0018] The ejector is fed from the compressed air supply of the cell. [0019] The blow-off valve is fed from the compressed air supply of the cell. [0020] The locking piston of the tool-change interface is fed from the compressed air supply of the cell. [0021] The blow-off valve and the lock of the tool-change interface are switched by the cell controller; the pressure sensor reports to the cell controller. 3. Operating sequence and conditions [0022] - When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. [0023] - When the vacuum level exceeds the gripping threshold, a secure grip is signalled by the pressure sensor. [0024] - The workpiece may not be lifted unless the pressure sensor signals a secure grip. [0025] - Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. [0026] - The workpiece is held until the blow-off valve has opened the circuit. [0027] The cell controller reads the pressure sensor (the manifold) and commands the blow-off valve, the tool-change interface; no sensor drives an actuator directly. 4. Parameters and operating assumptions [0028] Parameter values of this embodiment: locking of the tool-change interface: pneumatic (sets what has to be present at the interface for the tool to stay attached); material of the foam pad: sponge (sets the compliance of the sealing face); porosity of the foam pad: open cell (sets whether air passes through the pad body or only through openings cut through it); stages of the ejector: two (sets the flow drawn at low vacuum and the compressed air consumed while a sealed face is held); outlets of the manifold: three (sets how many lines can be fed from one inlet); material of the zone branches: plastic; zones of the zone branches: three (sets how much of the face can be treated separately); placement of the pressure sensor: at the manifold (sets where in the circuit the reading is taken and what it describes); duration of the blow-off valve: a sustained blast (sets how quickly the face clears and how much air each release costs); timing of the blow-off valve: before set-down (sets whether the pulse assists a drop release or clears the face after set-down). [0029] The workpiece is released while it is still above the receiving surface and falls the remaining distance onto it. This sequence is for a workpiece and a receiving surface that tolerate that drop, for example a part released into a container or onto a conveyor; the drop height is set by the application and is not fixed here. [0030] The blow-off is a sustained blast: the valve stays open for the whole release so that the face is cleared of dust and the workpiece is pushed positively away. [0031] The open-cell foam passes air through its whole face, so an uncovered part of the face draws air through the pad itself; the supply is sized for that continuous flow and the pad relies on flow restriction through the foam, not on a seal, to hold vacuum behind a covered area. [0032] The lock is engaged by compressed air acting on the locking piston and is held only while that air pressure is applied; what the lock does on loss of air pressure is not fixed by this arrangement. [0033] Vacuum levels are stated as gauge pressure below atmosphere. A stronger vacuum is a larger pressure difference below atmosphere, and the vacuum level 'exceeds the gripping threshold' when that difference is at least the threshold difference. 5. Provenance and status [0034] This document is an original combination composed from a typed library of mechanism blocks. Each block was derived from a published patent and carries typed connection points, the parameters its source states, and its own construction and operating description. The combination described here is proposed and has not been constructed. The published documents behind the blocks used in this arrangement are EP-4385681-B1, US-11427405-B1, US-11858125-B2, US-8006968-B2, US-8132312-B2, WO-2008134339-A4, WO-2026020244-A1; their text is not reproduced, and the description above is generated from the structure of the combination. ------------------------------------------------------------------------ OpenTechnical publication OT-2026-000089532 Published 2026-09-17T09:04:04.880043Z https://opentechnical.org/p/OT-2026-000089532 { "abstract": "A zoned vacuum gripping tool comprising one tool-change interface, one foam pad, one ejector, one manifold, three zone branches, one pressure sensor and one blow-off valve. When the foam pad reaches the workpiece, the foam pad is evacuated by the ejector. Before the workpiece reaches the set-down position, the workpiece is blown off by the blow-off valve while the workpiece is above the receiving surface. The arrangement is a proposed configuration composed from a typed library of mechanism blocks derived from published patents; it has not been constructed.", "canonical_url": "https://opentechnical.org/p/OT-2026-000089532", "categories": [ "robotics-automation/end-effectors/vacuum-grippers", "sensors-controls-machine-vision/force-and-pressure-sensing/vacuum-sensors", "industrial-motion-power-transmission/fluid-power/valves-and-manifolds", "robotics-automation/end-effectors/tool-changers" ], "extent": { "figures": 0, "paragraphs": 34, "words": 1237 }, "figures": [], "files": [ { "bytes": 19327, "media_type": "text/html; charset=utf-8", "name": "index.html", "sha256": "bb9959fc28706fc27992b9308156bb13d926b11477e3e6ddd74d5413bd04eb34" }, { "bytes": 8799, "media_type": "text/markdown; charset=utf-8", "name": "publication.md", "sha256": "16c02d52b72590f629a0242607424818be36b548c9bf0fc846b07c5bf85fd1e8" }, { "bytes": 8466, "media_type": "text/plain; charset=utf-8", "name": "publication.txt", "sha256": "088a47759e30dabce366ad01449a9bbbad4de9351542542540fbe81e7528ba68" } ], "integrity": { "hash_algorithm": "sha256", "keys_url": "https://opentechnical.org/integrity/keys", "record_url": "https://opentechnical.org/p/OT-2026-000089532/integrity", "signature_algorithm": "Ed25519", "signature_file": "manifest.sig", "verify_url": "https://opentechnical.org/integrity/verify" }, "keywords": [ "zoned vacuum tool", "tool-change interface", "foam pad", "ejector", "manifold", "zone branch", "pressure sensor", "blow-off valve", "blow off release", "compressed air supply" ], "language": "en", "license": { "name": "Creative Commons Attribution 4.0 International", "url": "https://creativecommons.org/licenses/by/4.0/" }, "publication_id": "OT-2026-000089532", "published_at": "2026-09-17T09:04:04.880043Z", "publisher": "Nebula Innovations Limited", "record_type": "disclosure", "schema": "opentechnical-publication-manifest/1.0", "supersedes": null, "title": "Foam pad vacuum gripper, three zone face, three outlet manifold, two stage ejector, manifold pressure sensor, sustained blow-off before set-down, on a tool changer", "uuid": "01a0ae9b-db02-766d-b2a1-bc93aec6244e" } Fv+xb6QVJNWVwNS9sOC/50pdIpynppyRtvogR3YB59WjSr9K5vsMZo9tsNg7MPCk2kNUKy3plFSnE4/xGW63AQ== algorithm: Ed25519 key_id: OT-SIGN-2026-01 public_key: https://opentechnical.org/integrity/keys signed_file: manifest.json signature_b64: Fv+xb6QVJNWVwNS9sOC/50pdIpynppyRtvogR3YB59WjSr9K5vsMZo9tsNg7MPCk2kNUKy3plFSnE4/xGW63AQ==